Loading...
HomeMy WebLinkAbout17456 Elkwood AveCITY OF LAKEVILLE CERTIFICATION OF GRADING AND FINAL PLACEMENT OF IRON MONUMENTS Building Permit #: 188961 Legal Description: Lot 12 Block 5 Subdivision: NORTH CREEK Address: 17456 Elkwood Avenue. Lakeville. Minnesota RECEIVED By Joey Pesik at 12:25 pm, Aug 30, 2021 We -F hereby certify that on 19th day of Auaust 2021 an inspection of this property was conducted by me or under my direct supervision and that the as -built grades, elevations and drainage patterns of the site and building are in conformance with the grading plan approved by the City Engineer or amendments previously approved by the City Engineer. In addition, all property corner monuments are in place as of this date. Exceptions noted. I hereby certify that this survey, plan or report was prepared by me or under my direct supervision and that I am a duly Licensed Land Surveyor under the laws of the State of Minnesota. Print Name: (/P .ter 1/ Hawkinson Signature: Date: August 20, 2021 MN License #: 42299 NOTE: ATTACH A COPY OF THE CERTIFICATE OF SURVEY SHOWING ALL AS - BUILT GRADES, ELEVATIONS AND DRAINAGE PATTERNS Approved subdivision grading plans should be obtained from the property owner or developer. General questions relating to the building permit should be directed to the Building Inspections Department at 952-985-4440. Questions relating to grading should be directed to the Engineering Department at 952-985-4500. Prior to release of the Grading Security, this document shall be filed with: City of Lakeville Engineering Department 20195 Holyoke Avenue Lakeville, MN 55044 Encls. 1 11x17 D `w 0 0 0 J w 30 ( 921 6 X 92/ 2 X 9 1.8 it--- - 5-----ir X 9121 9 O O NO0°14'47"E 30 Lot area = 3500 SF House area = 2524 SF Porch area = 49 SF Sidewalk area = 0 SF Driveway area = 78 SF Patio area = 120 SF Total Impervious Area = 2771 SF Impervious Coverage = 79.2% nstrl N 1. lnalrockconstruction entrance. 921 5 tD r 9214 912 0 11 r0 N i I 921.7 / : 921 3 X 921.1 922.6 922 8 923.0 922 2 X 922 7x - s2 '� 921 7-- 25.29i3a x922.6 921.3 X 921.1 X 922 1 922.8 at r Existing House Sodded X 922.7 923 7 922 8* 922 7 X p f » X 922.6 X g,22�4 __9_ 4 1 E _7_0.00 ____ ----fT-X 922 5> .-- -��- 9225 }-----) 921.7X 9214 ,� -J 922 3 O X 922.1 X 922.3 N X 921 9 minimal grade - x 9 2.8 7t�- 922.8 922.8 X 922.8 1 ` 923.4 1'I 11'L3.O x 922.7 922 3 X 922 7 9227 X 923.1 T 0 0 923 923.0 X9216 X9216 : 921 2 X 921 921.1 X 921.r X 921 9 9221 X 9221 X 922.5 923 1 922.6X 923 6 922 4 X 921 9 23 922.4 x x922.2 X 922.1 922 0X 922 0 X 922.6 922 5 923.2 x X X 922.5 Xs 9231 X X922II--8 922.6 9221s 25.5 O 5t7 i x9227 227 922.5x X minimal grade �r-a22 0 X922.2 X 923 1 32.3 9218 !_ 923.2 X 922.0 922.4 N89°45'13"W • 0 • 000.00 00o 00 ) 2. Install silt fence as needed for erosion control. 3. Sidewalks shall drain away from house a minimum of 1.0%. 4. Contractor must verify driveway design. 5. Contractor must verify service elevation prior to construction. 6. Add or remove foundation ledge as required. 7. Retaining walls are conditional; Wall installed if the grade exceeds 3:1 Wall will not be installed if the grade is 3:1 or less. /itX 9224 923.3 X 922.5 X 922 X9211 $9216 X 9227 6 X 922 4 X 920 / x 920.4 X 921.5 922.4 922.2 9221 70.00 Proposed House Staked Existing House Sodded Denotes iron pipe Denotes service Denotes television box Denotes electric box Denotes telephone box Denotes existing elevation Denotes proposed elevation Denotes drainage flow direction Denotes spike Denotes proposed retaining wall designed and built by others. X 9228 „ 2.9 N ro i X 922 3 X 921.9 X 922.3 �9221 X 922 5 X 921 5 X 922 0 923 0 922 9 X 922.3 0 o N 922 9 10 0 922.9 X 922 1 919.9 X x919 9 919.6 X 920.0 X 920 5 9204X i X 9199 X 920.7 1 921.0 1 0 4'% O 921.2 � I 921 i-5 l� 921 1 "4- X 920.5 X 920 9 X 921 2 920 8 1 I 923.1 X 921 3 IIx920 9 X 921.1 sz3^/o � � 921 3 Lx 226 711 .\222.8 X 922.2 X 921.5 X 922 2 .1)922 2 X 921 3 X 922.2 X 921 5 920 8 1 X 920 6 X 921.5 9211/ Q/ 920 8 920 6 922 1 921 8 X922.2 X X 921 7 Lowest floor elevation House elevations per grading plan 922.9 (Proposed) / As -built Top 0f Foundation Elev. :(923.6) / 923.6 Garage Slab Elev. © Door :(923.2) / 923.2 REVISED 8/19/21 General Notes: 1. Grading plan by KJ Walk last dated 9-5-19 was used to determine proposed elevations shown herein. 2. This survey does not purport to show improvements or encroachments, except as shown, as surveyed by me or under my direct supervision. 3. Proposed building dimensions shown are for horizontal location of structures on the lot only. Contact builder prior to construction for approved construction plans. 4 No specific soils investigation has been performed on this lot by the surveyor. The suitability of soils to support the specific house proposed is not the responsibility of the surveyor. 5. This certificate does not purport to show easements other than those shown on the recorded plat. 6. Bearings shown are based on an assumed datum. k PISNEERengineering, P.A, CIVn. ENGINEERS LAND PLANNERS LAND SURVEYORS LANDSCAPE ARCHITECTS 2422 Enterprise Dnve Ph. : (651) 681-1914 Mendota Heights, MN 55120 Fax: (651) 681-9488 www.ptoneereng com Project # .119254046 (Folder #:8421 (Drawn by CWM © Pioneer Engineering GRADING AS -BUILT We hereby certify to Brandt Anderson Homes plan or report was prepared by me or under and that I am a duly licensed Land Surveyor State of Minnesota, dated 02/26/21. BY: ressltirial Land Surveyor Minnesota License No. 42299 email-phawkinson@pioneereng.com Inc that this survey, my direct supervision, under the laws of the Signed: //Pionleer Engineering, P A Lot 12, Block 5, NORTH CREEK according to the recorded plat thereof Dakota County, Minnesota Address: 17456 Elkwood Avenue, Lakeville, Minnesota House Model: Crystal Elevation: 1 Buyer: Spec 3 4;;.. \ X 921 2 X 921.1 X 921 1 0' 10' 20' 111 Scale: 1" = 20' Benchmark: Top Nut Hydrant Lots 6-7 Block 4 Elevation = 923.86 Revisions 1) 03-01-21 Stake house 2 )08-19-21 Grading As -built Certificate of Survey for: Brandl Anderson Homes Inc 221 River Ridge Circle South, Suite 100 Burnsville, MN 55337 Phone- (952) 898-0230 • >r