Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LA196155 5765 178th St W Permit Pack
RESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received _______ _______ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov 9/10/21 DM RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: 20195 Holyoke Avenue, Lakeville, MN 55044 952-985-4400 952-985-4499 fax www.lakevillemn.gov Sewer & Water Tie Card Address:________________________________________ Contractor:______________________________________ Permit Number:__________________________________ Final Date:________________ Street Drain-Tile:______ Size of Water Service: 1” Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME OF SEWER & WATER INSPECTION MAIN FLOOR1' -8 1/4"UPPER PLATE20' -7 1/4"T.O. FOUNDATION0' -0"T.O. FOUNDATION0' -0"MAIN PLATE10' -9 3/8"MAIN PLATE10' -9 3/8"UPPER FLOOR12' -6 1/8"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"UPPER FLOOR PLATE HEIGHT8' - 1 1/8"VINYL BOARD& BATTEN TYP. @ FRONTSEE COLUMN DETAILSHEET A-501ALUMINUM SOFFIT& FASCIA TYP.VINYL SIDING TYP.6" SMARTSIDE TRIMTYP. @ FRONT4 BD. 6" PLANKSSTYLE SHUTTERS 6" BUMPED OUT LOUVERW/ CORBELS3' - 6"CULTURED STONEW/ CONCRETE CAPADDRESS STONE 6" SMARTSIDE FRIEZE BOARD @ FRONT TYP.6" SMARTSIDE STORY BOARD TYP. @ FRONT4" SMARTSIDE WINDOW & DOOR TRIM TYP @ FRONT8" 12"8" 12"7" / 12"4" / 12"GARAGE PLATE HEIGHT10' - 9 3/8"24" RETURNS TYP.8" / 12"8" / 12"7" 12"6" 12"7" / 12"ALUMINUM SOFFIT& FASCIA TYP.VINYL SIDING &CORNERS TYP.8" 12"7" / 12"6" / 12"7" 12"24" RETURNS TYP.7" 12"4" 12"8" / 12"8" / 12"7" / 12"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:8/25/2021 9:08:20 AMTHE ALI & WARSAME RESIDENCEL17, B1 -KNOB HILL 2ND ADDITION______ 178TH STREET WESTLAKEVILLE, MN 55044A-201OTT2446.23.21 CB1586139611177.27.21 CB8.9.21 CB8.24.21 CB6.22.21 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4099THE MADISON1/4" = 1'-0"A-2011FRONT ELEVATIONSHEET INDEXSHEET NUMBER SHEET NAMEA-201 ELEVATIONSA-401 FOUNDATIONA-402 LOWER FLOORA-403 MAIN FLOORA-404 UPPER FLOORA-501 SECTIONS - SCHEDULES - ROOF PLAN1/8" = 1'-0"A-2012LEFT ELEVATION1/8" = 1'-0"A-2013REAR ELEVATION1/8" = 1'-0"A-2014RIGHT ELEVATIONSecure door closed until deck isconstructed with a separate permit.Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode09/24/2021dmathews 20' - 6"10' - 0"0' - 2"18' - 6"30' - 6"49' - 0"1' - 4 1/2"8' - 3" M.O.0' - 4 1/2"2' - 1 1/2"16' - 3" M.O.2' - 1 1/2"0' - 4"0' - 4"*ALL DIMENSIONS ARE TO EXTERIOR OF CONCRETE, NOT INSULATION2" FOAM INSULATIONBETWEEN WALL & SLAB42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY57' - 0"1' - 0"5' - 10"19' - 4"6' - 10"38' - 2"12' - 0"42' - 0"7' - 0"49' - 0"2' - 0"21' - 6"23' - 6"21' - 6"12' - 0"57' - 0"22' - 4"22' - 8"15' - 10"6' - 10"17' - 7 1/4"3' - 10 3/4"3' - 10 3/4"12' - 9 1/4"3' - 9 1/2"8' - 5 1/4"29' - 9 1/4"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.6' - 3 1/4"15' - 2 3/4"8' - 3 1/4"14' - 4 3/4"ANCHOR BOLTS ON EACH SIDE OF BEARING POINT ANCHOR BOLTS ON EACH SIDE OF BEARING POINT 7'-8"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.*ALL DIMENSIONS ARE TO EXTERIOR OF CONCRETE, NOT INSULATION:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 10"(W) POUREDCONCRETE FOUND. WALL W/4" x 8" EXTERIOR LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.LEAVE A 12" GAP IN THE FOOTINGFOR PLUMBING11' - 6"14' - 0"16' - 6":WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY, BOTH SIDES.:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:8/25/2021 9:08:21 AMTHE ALI & WARSAME RESIDENCEL17, B1 -KNOB HILL 2ND ADDITION______ 178TH STREET WESTLAKEVILLE, MN 55044A-401OTT2446.23.21 CB1586139611177.27.21 CB8.9.21 CB8.24.21 CB6.22.21 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4099THE MADISON1/4" = 1'-0"A-4011FOUNDATION PLANUFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. UP 16RUNEXCAVATEDFURNACESUMPW. H.15' - 10"6' - 10"20' - 6"10' - 0"18' - 6"30' - 6"49' - 0"12' - 0"38' - 2"6' - 10"1' - 4 1/2"8' - 3" M.O.0' - 4 1/2"2' - 1 1/2"16' - 3" M.O.2' - 1 1/2"1' - 0"5' - 10"BEDROOM #523' - 6"21' - 6"12' - 0"21' - 6"2' - 0"SET ON 3X SILL2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.0' - 4"0' - 4"*ALL DIMENSIONS ARE TO OUTSIDE OF THE CONCRETE/ SHEATHING 19' - 4"22' - 8"5' - 6"12' - 4"22/4 x 6/8R.O. 2' -6" x 6' -11"4' VANITYF. D.MECHANICALBATHUNEXCAVATEDFAMILY ROOM12' - 0"30' - 0"CO DET.SMOKEDET.SMOKEDET.42' - 0"INSULATE BETWEEN WALL & SLAB22' - 4"6' - 6"10' - 0"7' - 0"7' - 0"4' - 10"6' - 8"21' - 6"16' - 8"2-2x102-9 1/2" LSLDROPPED2-9 1/2" LSL3-9 1/2" LVL W/4 TRIMMERS 4' - 6"5' - 10"9' - 0"17' - 10"3' - 8"3' - 8"13' - 0"4' - 0"7' - 4"8' - 0"ANCHOR BOLTS ON EACH SIDE OF BEARING POINT ANCHOR BOLTS ON EACH SIDE OF BEARING POINT 7' - 3"1' - 11"7' - 6"3' - 0" B.W.P.3-2x6*ALL DIMENSIONS ARE TO OUTSIDE OF THE CONCRETE/ SHEATHING 7' - 0"42' - 0"49' - 0"18" FLOOR TRUSSESPER MFG. SPACING18" FLOOR TRUSSESPER MFG. SPACING2x6STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.AIR EX.224-48-2448 SLR.O. 8' -0" x 4' -0"H.H. 6' -10"104836 PICR.O. 4' -0" x 3' -0"H.H. 1' -8 1/4"126048 SLR.O. 5' -0" x 4' -0"H.H. 6' -10"42/8 x 6/8R.O. 2' -10" x 6' -11"42/8 x 6/8R.O. 2' -10" x 6' -11"3' x 4' F.G.SHWR W/SURROUNDCLOSET11' - 6"14' - 0"16' - 6"18" FLOOR TRUSSESPER MFG. SPACING57' - 0"57' - 0"3-16" LVL 96/0 x 6/8 SLIDER6' - 0"6' - 0"324-48-2460 SLR.O. 8' -0" x 5' -0"H.H. 6' -10"22/4 x 6/8R.O. 2' -6" x 6' -11"32/6 x 6/8R.O. 2' -8" x 6' -11"MECHANICAL CHASE ABOVE 2-9 1/2" LSL 3 TRIMMERS 6" HOLE FOR HVAC ALLOWED MIDSPAN, SEE BEAM CALCULATION FOR DETAILS 2-2x105x5 PSL5x5 PSL1/4" = 1'-0"A-4021LOWER FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:8/25/2021 9:08:22 AMTHE ALI & WARSAME RESIDENCEL17, B1 -KNOB HILL 2ND ADDITION______ 178TH STREET WESTLAKEVILLE, MN 55044A-402OTT2446.23.21 CB1586139611177.27.21 CB8.9.21 CB8.24.21 CB6.22.21 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4099THE MADISON87.5333362.6Top of WallConnections8 UP 17RDN 16RDN 3RDN 3R16' - 6"14' - 0"11' - 6"OFFICESINKDW75/0 x 6/8 FULL VIEWR.O. 5' -2" x 6' -11"18' - 6"30' - 6"20' - 6"10' - 0"49' - 0"2' - 3"16' - 0"2' - 3"0' - 6"8' - 0"1' - 6"11' - 1"7' - 5"4" CONCRETE SLAB, SLOPETOWARDS DOORS5/8" TYPE X GYP. BD. ALL COMMONWALLS & CEILING IF FLOOR ABOVEGARAGE PLATE HEIGHT TOMATCH MAIN FLOOR UNLESS NOTED OTHERWISE1116' x 7' O.H. GARAGE DOOR52/8 x 6/8 FIRE RATEDR.O. 2' -10" x 6' -10 1/4"16' - 0"7' - 0"23' - 0"42' - 0"7' - 0"6' - 0"8' - 11"4' - 1"108' x 7' O.H. GARAGE DOORGARAGE23' - 0"KNEE WALL W/ 14" SPINDLES @ 6' -10" H.H.ABOVE LANDINGR-38 MIN. INSULATIONIN FLOOR ABOVESEE COLUMN DETAILSHEET A-5012' - 0"21' - 6"12' - 0"38' - 0"6' - 0"1' - 0"4' - 6"5' - 10"0' - 10"7' - 10"24" CANT. ABOVE 4' - 1 1/4"4' - 0"3' - 2"2' - 6"22/4 x 6/8R.O. 2' -6" x 6' -11"22/4 x 6/8R.O. 2' -6" x 6' -11"22/4 x 6/8R.O. 2' -6" x 6' -11"36" REFMUD ROOMPOWDERCLOSETKITCHENDINING0' - 4 1/2" TYP.GAS F.P.EQEQ63/0 x 6/8 W/ 12" D.S. SL'S11' - 0"12' - 0"6' - 0"6' - 0"3' - 5"11' - 0"7' - 1"16' - 6"5' - 6"0' - 6"PORCHPED. SINK0' - 10"10' - 3"12' - 0"21' - 6"23' - 6"GREAT ROOMFOYER12' - 10"3' - 8"3' - 8"17' - 10"2' - 0"19' - 0"5' - 0"GIRDER TRUSS 2-14" LVL2-11 7/8" LSL 2-2x12 2-2x8 DROPPED 2-2x10 W/2 TRIMMERS 2-9 1/2" LSL2-2x10 2-9 1/2" LSL CONT. W/2 TRIMMERS EA. SIDE2-2x102-2x105' - 11 1/4"4' - 2"7' - 2"0' - 10"5' - 2"6' - 0"4' - 10"5x5 PSL5x7 PSL3-2x6 11' - 2"5' - 0"2' - 10"3' - 10"2' - 2"16' - 0"(5) 16" SH.2x620" FLOOR TRUSSESPER MFG. SPACINGGIRDER TRUSS36" COOKTOP W/ WOOD HOOD ABOVE PAINTED CABINETS 12" FLUSH SANCK BARR & SH. @ 68"BENCH W/HOOKSOVEN /MICRO2-2x10 FLUSH5' - 0"6' - 2"32/6 x 6/8R.O. 2' -8" x 6' -11"11' - 6"1' - 2"3' - 10"2-9 1/2" LSL2-2x10 2-2x10 R & SH. @ 68"TECH TUBE OVER FIREPLACE 10"x10" GYP. BD SOFFIT3-2X6KNEE WALL W/14" SPINDLES 4' - 0"6' - 0"20" FLOOR TRUSSESPER MFG. SPACING20" FLOOR TRUSSESPER MFG. SPACING20" FLOOR TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.57' - 0"22' - 0"57' - 0"FIREPLACE SET12" A.F.F.TILE SURROUND W/ MANTEL 36" TALL BUILT INW/ 2 FLOATINGSHELVES36" TALL BUILT INW/ 2 FLOATINGSHELVES121-42-2160 SLR.O. 7' -0" x 5' -0"H.H. 6' -10"114860 PICR.O. 4' -0" x 5' -0"H.H. 12' -10"13P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"13P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"42424 AWN FIXEDR.O. 2' -0" x 2' -0"H.H. 6' -10"42424 AWN FIXEDR.O. 2' -0" x 2' -0"H.H. 6' -10"94242 SLR.O. 3' -6" x 3' -6"H.H. 7' -2"BOTTOM OF WINDOWFRAMED @ 44" A.F.F.PANTRYINSULATE GARAGE WALLS & CEILING 13P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"13P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"86/0 x 6/8 S.R. OPG.6' - 6"5' - 0"7' - 0"7' - 0"6' - 9"9' - 9"3.5:12 VAULT LINE 13P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"3.5:12 13P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"4 SEASONPORCH49' - 0"MFG. ROOF TRUSSES@ 24" O.C.96/0 x 6/8 SLIDERFRAME BOX FOR CHANDELIERMECHANICAL CHASE 2 TRIMMERS2-2x10 CONT. 2-9 1/2" LSL 2-2x10 1/4" = 1'-0"A-4031MAIN FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:8/25/2021 9:08:23 AMTHE ALI & WARSAME RESIDENCEL17, B1 -KNOB HILL 2ND ADDITION______ 178TH STREET WESTLAKEVILLE, MN 55044A-403OTT2446.23.21 CB1586139611177.27.21 CB8.9.21 CB8.24.21 CB6.22.21 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4099THE MADISONTemper ifglass within36" of landingFANVerify loads with girdertruss specs, may requireremoval of top plates atbearing due to crushing.BWPsAboveSmoke553.233ShearwallConnections96122.52.6PFHPFHProjec Date:Sheets A 34 www.h Print N Signed Date:I hereb was pr and tha under t S1FRAMING DETAILPERFORATED SHEARWALLRAISED ABOVE FLOOR SYSTEM5NOTEINFO APPLIES SYMMETRICALLY ACROSS DETAIL.CENTER BEARINGSTUDS BY SUPPLIERPROVIDE DOUBLE STUDS ATEACH END OF SHEARWALL(MAY USE BEARING/KINGSTUDS AS REQ'D)HEADER & BEARING/KINGSTUDS AT SIDES OFOPENINGS BY OTHERSHATCHED AREA INDICATES716" OR THICKERPLYWOOD/OSB EXTERIORSHEATHING FASTENED TOSTUDS w/ 8d NAILS @ 4"O.C. AT PANEL EDGES & @12" O.C. AT INTERIORSUPPORTSTYPICAL 2x6 STUDS @16" O.C.FASTEN BOTTOM PLATEw/ (3) 16d NAILS EVERY 16"FASTEN FRAMING ABOVE ASSHOWN FOR BRACED WALL PANELSSIMPSON STHD14HOLDOWN ANCHORFASTENED TO DOUBLESTUDS (REFER TO 6/S1FOR POST-INSTALLEDHOLDOWN OPTION)PROVIDE DOUBLE STUDSFOR ATTACHMENT OFBOTH STRAP & HOLDOWN(MAY USE BEARING/KINGSTUDS AS REQ'D)SIMPSON MSTC52 STRAPCENTERED ON FLOORSYSTEM AT LOCATIONSHOWN (PROVIDE 2xBLOCKING IN FLOORSPACE AS REQ'D) DN 17RLOFT42' - 0"8' - 4 1/8"17' - 11 7/8"8' - 8"7' - 0"CO DET.SMOKEDET.SMOKEDET.SMOKEDET.ATTICACCESS12' - 0"7' - 0"23' - 0"42/8 x 6/8R.O. 2' -10" x 6' -11"32/6 x 6/8R.O. 2' -8" x 6' -11"8'-10" VANITY22/4 x 6/8R.O. 2' -6" x 6' -11"3.5:12BEDROOM #4BEDROOM #3CLOSETCLOSETBATHEN SUITEOWNER'S SUITE22/4 x 6/8R.O. 2' -6" x 6' -11"22/4 x 6/8R.O. 2' -6" x 6' -11"40' - 0"36' - 6"1' - 6"2' - 0"40' - 0"KNEE WALL W/14" SPINDLES 17' - 10"3' - 8"3' - 8"14' - 10"4' - 6"5' - 10"31' - 8"42/8 x 6/8R.O. 2' -10" x 6' -11"32/6 x 6/8R.O. 2' -8" x 6' -11"22/4 x 6/8R.O. 2' -6" x 6' -11"3.5:122-2x102-2x102-9 1/2" LSL2-2x102-2x102-2x102-2x102-2x1042' - 0"11' - 0"8' - 8 1/4"16' - 9 3/4"6' - 0"6' - 0"3' - 5"3' - 7"2' - 6"20' - 6"21' - 6"18' - 6"KNEE WALL W/14" SPINDLES 11' - 2"3' - 0 1/4"5' - 2 3/4"3' - 4"8' - 9"5' - 0"6' - 5"5' - 3 1/4"3' - 1"1' - 8"1' - 3"0' - 11 3/4"4' - 1"2' - 7"11' - 2"15' - 4"4' - 3"2' - 3"6' - 8"3' - 4"10' - 2"12' - 3"3' - 9"2' - 6"11' - 5"5' - 11"6' - 2"GLASS PANEL SMOKEDET.42/8 x 6/8R.O. 2' -10" x 6' -11"FOLDING COUNTEROPEN TO BELOW 10' - 2"3' - 5"2' - 0"6' - 2"4' - 11"5' - 0"32/6 x 6/8R.O. 2' -8" x 6' -11"42/8 x 6/8R.O. 2' -10" x 6' -11"R & SH. @ 68"22/4 x 6/8R.O. 2' -6" x 6' -11"5' TUB/SHWR(5) 16" SH.3' - 2"60" F.G. BASEW/ C.T. WALLS12/4 SHWR DR.0' - 6"3'x5' WHIRLPOOLTUB (1) SHAMPOO SHELF22/4 x 6/8R.O. 2' -6" x 6' -11"3' LINENR & SH. @ 68"R & SH. @ 68"R & SH. @ 68"SMOKEDET.BEDROOM #22x62-2x10VAULT LINE 3-2x6GIRDER TRUSS3-2x6CLOSETLAUNDRYMFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.L.T.324-48-2460 SLR.O. 8' -0" x 5' -0"H.H. 6' -10"126048 SLR.O. 5' -0" x 4' -0"H.H. 6' -10"83648 PIC. TEMPR.O. 3' -0" x 4' -0"H.H. 6' -10"126048 SLR.O. 5' -0" x 4' -0"H.H. 6' -10"63636 SLR.O. 3' -0" x 3' -0"H.H. 6' -10"126048 SLR.O. 5' -0" x 4' -0"H.H. 6' -10"73648 CSMT ER.O. 3' -0" x 4' -0"H.H. 6' -10"94242 SLR.O. 3' -6" x 3' -6"H.H. 6' -10"52424-3 AWN FIXEDR.O. 6' -0" x 2' -0"H.H. 6' -10"DRYERWASHER6' VANITY2x61'-6" LINENTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:8/25/2021 9:08:24 AMTHE ALI & WARSAME RESIDENCEL17, B1 -KNOB HILL 2ND ADDITION______ 178TH STREET WESTLAKEVILLE, MN 55044A-404OTT2446.23.21 CB1586139611177.27.21 CB8.9.21 CB8.24.21 CB6.22.21 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4099THE MADISON1/4" = 1'-0"A-4041UPPER FLOOR PLANTemper if within60" of floorFANFANFAN-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).3.5 1' - 5"0' - 9 1/2"2x4 @ BOTTOM1x3 TYP.2x22x4 @ TOPSMOOTH LPSMARTSIDE TYP.SOFFIT1' - 9 1/2"1' - 0"FRONTSIDETOP VIEW1' - 5"0' - 9 1/2"FRAMING4x4 POSTWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALER6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETRT'D 2x8 SILL PLATEW/ CLOSED CELL ROLLSILL SEALERGRADEGRANULAR FILL4" DRAIN TILEW/ SILT SOCK1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOORLOWER PLATE HEIGHT 8' - 2"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.VERIFY FLOOR SYSTEMWITH FLOOR PLANSUPPER FLOOR PLATE HEIGHT8' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.3/4" T&GSUBFLOOR6 MIL. V.B.2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.1/2" OSBSHEATHINGTYVEK (OR EQUAL)ROLL HOUSE WRAPSIDING, VERIFYW/ ELEVATIONS5/8" GYP. BD.5/8" GYP. BD.VENTED ALUMINUMSOFFIT PANELSICE & WATER GUARDFROM EAVE TO 2'-0"MIN. OVER STRUCTUREVENT CHUTES & WIND WASH@ EACH TRUSS SPACEASPHALT SHINGLES W/15# ROLL FELT UNDER1/2" OSB ROOF SHEATHINGMFG. ROOFTRUSSES @ 24" O.C.ATTIC VENTINGAS PER CODER-49 MIN. BLOWNATTIC INSULATIONALUMINUM FASCIA W/2x6 SUB FASCIAALUMINUMDRIP EDGERIM JOISTRIM JOISTR-20 MIN. SPRAYFOAM INSULATION,COVER FOUNDATION WALLGMX THERMAL DRAINAGE BOARD(R-10) INSULATIONDRYVIT INSULATIONPROTECTION FROM SIDINGTO 6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITH OUTSIDE OF SHEATINGR-20 MIN. SPRAYFOAM INSULATION6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"5000 PSI CONCRETE@ ALL FOOTINGS2" FOAMBOARD(R-10) INSULATION4" DRAIN TILEW/ SILT SOCKWATER PROOF COATING FROM FOOTING TOSILL SEALERWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESINSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONINSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITHOUTSIDE OF SHEATHINGANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" OSBSHEATHINGRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESTOOP, FLASH AS REQ'DAT HOUSE WALLPOUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERSIDING, VERIFYW/ ELEVATIONSTYVEK (OR EQUAL) ROLL HOUSE WRAP0' - 2"FROM SHEATHING TOOUTSIDE OF FOUNDATIONANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION5/8" TYPE 'X' GYP BOARD,TAPE & MUD ALL SEAMSRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESLAB, FLASH AS REQ'DAT HOUSE WALL0' - 4"POUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERVERIFY FLOOR SYSTEMWITH FLOOR PLANS0' - 8"ALL DUCT WORK & PLUMBING TO REMAIN ABOVE INSULATIONTYVEK OR EQUALHOUSE WRAP5/8" TYPE 'X'GYP. BD., TAPE &MUD ALL SEAMS1" RIGID INSULATION3/4" T&G SUBFLOORR-30 MIN.BLOWN INSULATIONFLOOR TRUSS2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.TRT'D SILL PLATEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSSLEEVE EVERY10'-0" MIN.6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODE5000 PSI CONCRETE@ ALL FOOTINGS18" OVERHANGS & 12" RAKES TYP.STANDARD ENERGY HEELS @ 4:12 & 7:12 SLOPEW/ 6:12 & 8:12 TO MATCH FASCIA LINES 8 ROOF VENTS REQUIRED 2 ROOF VENTS REQUIRED7" / 12"7" / 12"8" / 12"8" / 12"4" / 12"8" / 12"8" / 12"6" / 12"7" / 12"7" / 12"1 ROOF VENT REQUIRED THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:8/25/2021 9:08:25 AMTHE ALI & WARSAME RESIDENCEL17, B1 -KNOB HILL 2ND ADDITION______ 178TH STREET WESTLAKEVILLE, MN 55044A-501OTT2446.23.21 CB1586139611177.27.21 CB8.9.21 CB8.24.21 CB6.22.21 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4099THE MADISON1/2" = 1'-0"A-5012TYP. COLUMNWINDOW SCHEDULETYPE MARK MANUFACTURER MODEL COUNT UNIT ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT1 WINDSOR NEXT DIMENSION 1 21-42-2160 SL 7' - 0" 5' - 0" 6' - 10"2 WINDSOR NEXT DIMENSION 1 24-48-2448 SL 8' - 0" 4' - 0" 6' - 10"3 WINDSOR NEXT DIMENSION 2 24-48-2460 SL 8' - 0" 5' - 0" 6' - 10"4 WINDSOR NEXT DIMENSION 2 2424 AWN FIXED 2' - 0" 2' - 0"6' - 10"5 WINDSOR NEXT DIMENSION 1 2424-3 AWN FIXED 6' - 0" 2' - 0" 6' - 10"6 WINDSOR NEXT DIMENSION 1 3636 SL 3' - 0" 3' - 0" 6' - 10"7 WINDSOR NEXT DIMENSION 1 3648 CSMT E 3' - 0" 4' - 0" 6' - 10"8 WINDSOR NEXT DIMENSION 1 3648 PIC. TEMP 3' - 0" 4' - 0"6' - 10"9 WINDSOR NEXT DIMENSION 2 4242 SL 3' - 6" 3' - 6" VARIES10 WINDSOR NEXT DIMENSION 1 4836 PIC 4' - 0" 3' - 0" 1' - 8 1/4"11 WINDSOR NEXT DIMENSION 1 4860 PIC 4' - 0" 5' - 0" 12' - 10"12 WINDSOR NEXT DIMENSION 4 6048 SL 5' - 0" 4' - 0" 6' - 10"13 WINDSOR NEXT DIMENSION 6 P4260/A24 T 3' - 6" 7' - 0" 8' - 0"3/8" = 1'-0"A-5013TYP. WALL SECTIONROOM FINISHED SCHEDULEFLOOR ROOM NAME FLOORING AREA CEILING HEIGHT COMMENTSLOWER FLOOR BEDROOM #5 CARPET 126 SF 8' - 2" .LOWER FLOOR FAMILY ROOM CARPET 746 SF 8' - 2" .LOWER FLOOR STAIRWAY CARPET 72 SF 8' - 2"LOWER FLOOR CLOSET CARPET 53 SF 8' - 2"LOWER FLOOR MECHANICAL UNFINISHED 131 SF 8' - 2" MECHANICALS MAY VERYLOWER FLOOR BATH VINYL 48 SF 8' - 2" .MAIN FLOOR 4 SEASON PORCH 150 SF 9' - 1 1/8" VAULTEDMAIN FLOOR OFFICE CARPET 125 SF 9' - 1 1/8" .MAIN FLOOR GARAGE CONCRETE 644 SF 10' - 9 3/8"MAIN FLOOR PORCH CONCRETE 111 SF 9' - 1 1/8" .MAIN FLOOR MUD ROOM VINYL 60 SF 9' - 1 1/8" .MAIN FLOOR POWDER VINYL 29 SF 9' - 1 1/8" .MAIN FLOOR CLOSET VINYL 30 SF 9' - 1 1/8" .MAIN FLOOR KITCHEN WOOD 172 SF 9' - 1 1/8" .MAIN FLOOR DINING WOOD 191 SF 9' - 1 1/8" .MAIN FLOOR PANTRY WOOD 18 SF 9' - 1 1/8"MAIN FLOOR GREAT ROOM WOOD 254 SF 9' - 1 1/8" .MAIN FLOOR FOYER WOOD 153 SF 9' - 1 1/8" .UPPER FLOOR LOFT CARPET 304 SF 8' - 1 1/8" .UPPER FLOOR BEDROOM #4 CARPET 142 SF 8' - 1 1/8" .UPPER FLOOR BEDROOM #3 CARPET 132 SF 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 24 SF 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 24 SF 8' - 1 1/8" .UPPER FLOOR OWNER'S SUITE CARPET 250 SF 8' - 1 1/8" VAULTEDUPPER FLOOR BEDROOM #2 CARPET 157 SF 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 64 SF 8' - 1 1/8" .UPPER FLOOR STAIRS CARPET 78 SF 8' - 1 1/8"UPPER FLOOR EN SUITE L.V.T. 135 SF 8' - 1 1/8" .UPPER FLOOR BATH VINYL 61 SF 8' - 1 1/8" .UPPER FLOOR LAUNDRY VINYL 66 SF 8' - 1 1/8"DOOR SCHEDULETYPE MARK DOOR SIZE COUNT ROUGH WIDTH ROUGH HEIGHT COMMENTS1 2/4 SHWR DR. 12 2/4 x 6/8 11 2' - 6" 6' - 11"3 2/6 x 6/8 5 2' - 8" 6' - 11"4 2/8 x 6/8 6 2' - 10" 6' - 11"5 2/8 x 6/8 FIRE RATED 1 2' - 10" 6' - 10 1/4"6 3/0 x 6/8 W/ 12" D.S. SL'S 17 5/0 x 6/8 FULL VIEW 1 5' - 2" 6' - 11"8 6/0 x 6/8 S.R. OPG. 19 6/0 x 6/8 SLIDER 210 8' x 7' O.H. GARAGE DOOR 111 16' x 7' O.H. GARAGE DOOR 13" MIN. ABS OR PVC GASTIGHT PIPE FROM SUBSLAB TO MIN.12" ABOVE ROOF, MUST BE RUN THRU CONDITIONED SPACE.PIPE CAN BE CONNECTED TO SUMP SYSTEM OR HAVE"T" FITTING (MIN. 10'-0" EA. WAY) IN GRAVEL UNDER SLAB.END OF PIPE MUST BE MIN. 10'-0" AWAY FROM ANY WINDOW OROTHER OPENING THAT IS LESS THAN 2'-0" BELOW END OF PIPE. END OF PIPE MUST ALSO BE MIN. 10'-0" AWAY FROM ANYWINDOW OR OTHER OPENING IN ADJOINING OR ADJACENT BUILDINGS.SUFFICIENT SPACE MUST BE LEFT AROUND PIPE IN ATTIC SPACETO ADD FAN. SPACE MUST BE MIN. ∅24" CENTERED ON AXIS OFPIPE W/ MIN. 3'-0" VERTICAL SPACE.A SINGLE PIPE CAN BE USED IF ALL SOIL GASES IN DWELLING CANFLOW FREELY BETWEEN ALL LEVELS OF FOUNDATION. THIS INCLUDESINTERIOR FOOTINGS & OTHER BARRIERS IF AIRFLOW HAS BEEN ESTABLISHED.LABEL THE VENT PIPE AT LEAST ONCE PER FLOOR AND IN ACCESSIBLE ATTICSWITH "RADON REDUCTION SYSTEM".ONE ELECTRICAL RECEPTACLE IS REQUIRED IN THE ATTIC NEARTHE VENT PIPE FOR OPT. FAN.:PASSIVE RADON SYSTEM:1/2" = 1'-0"A-5011TYP. WALKOUT SECTION1/2" = 1'-0"A-5014TYP. LOOKOUT SECTION1/2" = 1'-0"A-5015TYP. HOUSE/STOOP WALL1/2" = 1'-0"A-5016TYP. HOUSE/GARAGE WALL1/2" = 1'-0"A-5018GARAGE CEILING1/2" = 1'-0"A-5019BEARING WALL SECTION1/8" = 1'-0"A-50110ROOF PLAN COPYRIGHT HANSON GROUP, LLC 2021©September 14, 2021Project Number:Date:1.495S11Sheets: of1PLANS SHOWN LIGHT IN BACKGROUND ARE FORLOCATION REFERENCE ONLY. PLAN NOTES ANDELEMENTS SHOWN LIGHT MAY NOT NECESSARILYSUPPORT THE HANSON GROUP'S DESIGN.DescriptionDateRevisionAli & Warsame ResidenceXXXX 178th St WLakeville, MN3407 Kilmer Lane NorthSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comPrint Name:Signed: License Number:9-14-21Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.OneTenTen Homes3000 County Road 42 WSuite 202Burnsville, MN 55337Garrett Brunell52600UPPER LEVEL PLAN SHOWN FORLOCATION REFERENCE ONLY3S1REFERENCE PLANS1FRAMING DETAILPERFORATED SHEARWALLRAISED ABOVE FLOOR SYSTEM5NOTEINFO APPLIES SYMMETRICALLY ACROSS DETAIL.CENTER BEARINGSTUDS BY SUPPLIERS1FRAMING DETAILGARAGE FRONT PORTAL FRAME4NOTEINFO APPLIES SYMMETRICALLY ACROSS DETAIL.2'-1 12"±16'-3"±10'-9 38" MAX FASTEN TOP PLATE TO HEADER w/ (2)ROWS 16d SINKER NAILS @ 3" O.C.(1) 2x6 BEARING STUD & (1) 2x6 FULLHEIGHT STUD EACH END OF HEADERCONTINUOUS LSL/LVL HEADER TOSUPPORT VERTICAL LOADS BY SUPPLIER(MIN.312" WIDTH & MIN.1178" DEPTH REQ'D)LOCATE PANEL JOINT WITHIN 2'-0" FROMCENTER OF HEADER AS REQ'D (2x SOLIDBLOCKING REQUIRED AT SHEATHING JOINT)(2) 2x6 BEARING STUDS MIN.(VERIFY w/ SUPPLIER)PROVIDE 2x6 INFILL WALL ABOVE HEADERAS REQ'DFOUNDATION WALL BELOWLENGTH OF CONTINUOUS HEADERNAIL SHEATHING TO HEADER w/ 8dNAILS @ 3" O.C. EA. WAY TYP.SMALL HATCH AREA INDICATES 716" ORTHICKER PLYWOOD OR OSB SHEATHINGAPPLIED TO EXTERIOR SIDE OF STUDS(NAIL SHEATHING AROUND PERIMETER w/(2) ROWS 8d NAILS @ 3" O.C. STAGGERED &TO PLATES / BLOCKING @ 3" O.C.)FASTEN KING STUD TO HEADER w/(2) ROWS 16d SINKER NAILS @ 3" O.C.2'-112"±(2) 58" Ø ANCHOR BOLTS (7" MIN. EMBED)w/ 2"x2"x316" PLATE WASHERSFASTEN FRAMING ABOVE ASSHOWN FOR BRACED WALL PANELSLARGE HATCH AREA INDICATES 716" ORTHICKER PLYWOOD OR OSB SHEATHINGAPPLIED TO EXTERIOR SIDE OF STUDS w/STANDARD 6"/12" NAILINGMAIN FLOOR PLAN SHOWN FORLOCATION REFERENCE ONLY2S1REFERENCE PLANPARTIAL LOWER FLOOR PLAN SHOWNFOR LOCATION REFERENCE ONLY1S1REFERENCE PLANCONCRETEFOUNDATIONBELOWSIMPSON HTT5HOLDOWN ANCHOR ATLOCATIONS SHOWN w/12"Ø x 12" LONGSIMPSON TITEN HDSCREW-IN ANCHORPOST-INSTALLED HOLDOWN OPTION6S1FRAMING DETAIL SECTION 7S1AT BRACED WALL PANELS ABOVECANTILEVERED FLOOR FRAMINGNOTESECTION ONLY APPLIES WHEN BRACED WALLPANELS OR SHEARWALLS ARE LOCATED ABOVEFLOOR CANTILEVER. SEE PLAN FOR APPLICABILITY.BRACED WALL PANELFASTEN BOTTOM PLATE TORIBBON BRACE / TRUSS w/(3) 16d NAILS EVERY 16" O.C.CANTILEVERED FLOORTRUSS BY SUPPLIERFRAMEWALL / BRACEDWALL PANEL BELOWBLOCKING BETWEEN TRUSSES AS FOLLOWS:·FLAT 2x4 TOP & BOTTOM·34" PLYWOOD SHEET NAILED TO 2x4's w/(8) 8d NAILS TOP & BOTTOM·CIRCULAR HOLE UP TO 8"Ø MAY BE CUTINTO CENTER OF PLYWOODNAIL FLOOR SHEATHING TOBLOCKING w/ 8d NAILS @ 6" O.C.FASTEN BOTTOM 2x4 w/ (3) 16dNAILS EVERY 16" O.C.PROVIDE DOUBLE STUDS ATEACH END OF SHEARWALL(MAY USE BEARING/KINGSTUDS AS REQ'D)HEADER & BEARING/KINGSTUDS AT SIDES OFOPENINGS BY OTHERSHATCHED AREA INDICATES716" OR THICKERPLYWOOD/OSB EXTERIORSHEATHING FASTENED TOSTUDS w/ 8d NAILS @ 4"O.C. AT PANEL EDGES & @12" O.C. AT INTERIORSUPPORTSTYPICAL 2x6 STUDS @16" O.C.FASTEN BOTTOM PLATEw/ (3) 16d NAILS EVERY 16"FASTEN FRAMING ABOVE ASSHOWN FOR BRACED WALL PANELSSIMPSON STHD14HOLDOWN ANCHORFASTENED TO DOUBLESTUDS (REFER TO 6/S1FOR POST-INSTALLEDHOLDOWN OPTION)PROVIDE DOUBLE STUDSFOR ATTACHMENT OFBOTH STRAP & HOLDOWN(MAY USE BEARING/KINGSTUDS AS REQ'D)SIMPSON MSTC52 STRAPCENTERED ON FLOORSYSTEM AT LOCATIONSHOWN (PROVIDE 2xBLOCKING IN FLOORSPACE AS REQ'D)BRACED WALL LINE CONSTRUCTPERFORATEDSHEAR WALL ASSHOWN IN 5/S1(4-FT)(4-FT)(4-FT)SIMPSON STHD14 EMBEDDED HOLDOWNANCHOR AT LOCATIONS SHOWN(REFER TO 6/S1 FOR ALTERNATIVE OPTION)SIMPSON MSTC40 STRAP ON INSIDE FACEOF WALL (PROVIDE SPACER TO FLUSHOUT HEADER TO WALL STUD THICKNESS)SCOPEDESIGN AND DETAIL OF THE MAIN WINDFORCE RESISTING SYSTEM FOR A SINGLE FAMILY RESIDENCE.CONSTRUCTION IS TO BE IN ACCORDANCE WITH THESE DRAWINGS, STANDARD INDUSTRY PRACTICE, ANDTHE REQUIREMENTS OF THE CODE.GENERAL NOTES1.THESE DOCUMENTS APPLY TO STRUCTURAL ONLY. REFER TO HOUSE PLANS PREPARED BY NORTHHOUSE RESIDENTIAL DESIGN LAST DATED 8-24-21 FOR MORE INFORMATION.2.THE HANSON GROUP'S ENGINEERING IS LIMITED TO THE ITEMS LISTED IN THE PROJECT SCOPE ABOVE.THE DESIGN OF THE REMAINING HOME, INCLUDING ALL BEAM AND HEADER SIZES IS BY OTHERS.3.CONTRACTOR AND BUILDER ARE TO VERIFY ALL DIMENSIONS AND CONDITIONS BEFORE PROCEEDINGWITH WORK. NOTIFY THE HANSON GROUP IF DISCREPANCIES ARISE.4.MEANS AND METHODS OF CONSTRUCTION ARE THE RESPONSIBILITY OF THE CONTRACTOR.FRAMING NOTES1.ALL EXTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA,U.N.O., WHICH MEETS OR EXCEEDS THE REQUIREMENTS OF CODE SECTION R602.10.4-WSP AND CS-WSP.A.2x6 STUDS SPACED @ 16" O.C.B.EXTERIOR SHEATHING: 716" MIN. STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C ATPANEL EDGES AND 12" O.C. AT INTERMEDIATE SUPPORTS OR 134" 16 GAUGE STAPLES @ 3" / 6"SPACING.2.ALL INTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O.A.2x4 OR 2x6 STUDS SPACED @ 16" O.C.B.WALL SHEATHING: 12" MIN. GYPSUM SHEATHING FASTENED TO FRAMING w/ 5d COOLER NAILS @ 8" O.C.MAX. OR TYPE S/W WALLBOARD SCREWS @ 16" O.C. MAX. (58" MINIMUM STUD PENETRATION)3.ALL FLOORS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA.A.FLOOR FRAMING SPACED AT A MAXIMUM OF 24" O.C.B.FLOOR SHEATHING: 34" STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANELEDGES AND 12" O.C. AT INTERMEDIATE SUPPORTS.4.ALL ROOFS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA.A.ROOF FRAMING SPACED AT A MAXIMUM OF 24" O.C.B.FASTEN ALL ROOF FRAMING TO TOP PLATES WITH SIMPSON H2.5 CLIP OR EQUIVALENT AND (4) 0.131"Øx 3" TOENAILS.C.ROOF SHEATHING: 12" STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANELEDGES AND 12" O.C. AT INTERMEDIATE SUPPORTS OR 134" 16 GAUGE STAPLES @ 3" / 6" SPACING.5.ALONG LENGTH OF WALLS, LAP WALL TOP PLATES A MINIMUM OF 24" AND FASTEN TOGETHER WITH (12)0.131"Ø x 3" IN LAP ZONE. AT CORNERS AND INTERSECTIONS, LAP PLATES AND PROVIDE (3) 0.131"Ø x 3"FACE NAILS.6.CONNECTIONS NOT SPECIFICALLY NOTED ARE TO BE IN ACCORDANCE WITH CODE TABLE R602.3(1).7.TALL WOOD WALL FRAMING IS TO BE DESIGNED BY SUPPLIER FOR GRAVITY AND OUT-OF-PLANE WINDLOADS.8.THE ENTRY PORCH IS CONSIDERED TO BE A PRIMARILY OPEN, NON-ESSENTIAL PORTION OF THESTRUCTURE AND IS EXCLUDED FROM THE OVERALL MAIN WINDFORCE SYSTEM OF THE HOME. PROVIDECODE REQUIRED UPLIFT CONNECTIONS AT ALL POSTS.MATERIALSWALL STUDS (10' OR LESS):SPF STUD GRADE OR BETTERWALL STUDS (OVER 10'):SPF NO.2 GRADE OR BETTERDIMENSIONAL LUMBER:SPF NO.2 GRADE OR BETTERTREATED LUMBER:SYP NO.2 GRADE OR BETTERLVL:134" WIDTH - 1.9E OR BETTERLSL STUDS:112" WIDTH - 1.3E OR BETTERLOADSROOF LIVE LOAD: 35 PSF (SNOW)ROOF DEAD LOAD:15 PSFFLOOR LIVE LOAD:40 PSFFLOOR DEAD LOAD:15 PSFWIND LOAD:115 MPH ULTIMATE EXP. BCODE2020 MINNESOTA RESIDENTIAL CODEINDICATES EXTERIOR BRACED WALL PANEL w/ SHEATHING ON EXTERIOR FACE IN ACCORDANCE w/ FRAMING NOTE 1.PROVIDE INCREASED FASTENING REQUIREMENTS AS SHOWN BELOW.INDICATES ENGINEERED WIND RESISTING ELEMENTS TO BE CONSTRUCTED AS SHOWN IN THE DETAIL SHEETS.(MIN. LENGTH)(MIN. LENGTH)THESE SHEETS REPRESENT A COMPLETE DESIGN OF THE "MAIN WINDFORCE RESISTING SYSTEM" FOR THE ENTIRE RESIDENTIAL STRUCTURE.THE LOCATION AND LENGTH OF EACH BRACED WALL PANEL AND ENGINEERED WIND RESISTING ELEMENT THAT IS REQUIRED FOR THE HANSONGROUP'S DESIGN IS SHOWN ON THE STRUCTURAL DRAWINGS. WALLS NOT SPECIFICALLY LABELED ON THE PLANS MAY BE STANDARD FRAMING.ROOFTRUSSESBRACEDWALL PANELFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)SIMPSONA35FRAMINGANGLEEACH END(4) 0.131"Øx 3" NAILSBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONLTP4FRAMINGPLATEEACH ENDFLOORTRUSSESFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)BRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONLTP4FRAMINGPLATEEACH ENDFLOORTRUSSESFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)BRACED WALL CONNECTIONBRACED WALL CONNECTION(ROOF TRUSSES)(FLOOR TRUSSES)DETAILS SHOWN ABOVE AREALTERNATIVE CONNECTIONS TO BEUSED WHEN BRACED WALL PANELDOES NOT ALIGN WITH FRAMING.INDICATES INTERIOR BRACED WALL PANEL w/ GYPSUM SHEATHING BOTH FACES WITH EITHER FASTENER OPTION LISTED INFRAMING NOTE 2, SPACED AT 4" O.C. PROVIDE INCREASED FASTENING REQUIREMENTS AS SHOWN BELOW.SECTIONS SHOWN DEPICT CONNECTIONS OF BRACED WALL PANELS TO ROOF TRUSSESABOVE, TO TRUSSES/BLOCKING ABOVE, AND TO TRUSSES/BLOCKING BELOW. THESE PANELSARE NOT NECESSARILY REQUIRED TO ALIGN, BUT MAY DEPENDING ON PLAN LAYOUT.EXTERIOR NON-BEARING WALLFRAME 2x4 BOXAROUND SPACEBETWEEN TRUSS w/SAME SHEATHINGAND FASTENING ASWALL BELOW(OR REPLACE w/ADEQUATE DEPTH2x MEMBER)#12 x 312" WOODSCREWS @ 16" O.C.INSTALLED INADDITION TO NAILS(MAIN/UPPERLEVEL ROOFTRUSS BEARINGWALLS ONLY)EXTERIOR BEARING WALLREPRESENTSFIGURER602.10.8.2(3)w/ TRUSSESw/ TRUSSESROOF TRUSSESFASTENED TO PLATESw/ (4) 0.131"Ø x 3"TOENAILS & SIMPSONH2.5 CLIPNAIL BOTTOM PLATETO RIBBON BRACE /TRUSS w/ (3) 16dNAILS EVERY 16"2x4 BLOCKINGBETWEENTRUSSES NAILEDTO TOP PLATESw/ (3) 0.131"Ø x 3"NAILS EACHNAIL EACH TRUSS TOTOP PLATES w/ (3)0.131"Ø x 3" TOENAILSROOF TRUSSFASTENED TOPLATES w/0.131"Ø x 3"TOENAILS@ 6" O.C.NAIL BOTTOMPLATE TO LADDERTRUSS w/ (3) 16dNAILS EVERY 16"NAIL LADDERTRUSS TO TOPPLATES w/0.131"Ø x 3"NAILS @ 6" O.C.w/ TRUSSESw/ TRUSSESINTERIOR WALLPERPENDICULAR TO FRAMINGINTERIOR WALLPARALLEL w/ FRAMING2x4 BLOCKING BETWEENROOF TRUSSES NAILEDTO TOP PLATES w/ (3)0.131"Ø x 3" NAILS EACHNAIL BOTTOM PLATE TOBLOCKING w/ (3) 16dNAILS EVERY 16"PROVIDE FULL DEPTHBLOCKING BETWEEN TRUSSESNAILED TO TOP PLATES w/(3) 0.131"Ø x 3" NAILS EACHNAIL EACH TRUSS TO TOP PLATEw/ (3) 0.131"Ø x 3" TOENAILSPROVIDE ROOF TRUSSDIRECTLY IN LINE w/BRACED WALL PANELFASTENED TO PLATESw/ 0.131"Ø x 3"TOENAILS @ 6" O.C.NAIL BOTTOM PLATETO BLOCKING w/ (3)16d NAILS EVERY 16"PROVIDE TRUSS DIRECTLYIN LINE w/ BRACED WALLPANEL FASTENED TOPLATES w/ 0.131"Ø x 3"TOENAILS @ 6" O.C.NAIL BOTTOM PLATE w/(3) 16d NAILS EVERY 16"(OR AS SHOWN TOTHE RIGHT IF REQ'D)FASTEN PLATE w/ 14" CONCRETESCREWS OR POWDERACTUATED 0.145" WASHEREDPINS @ 16" O.C. w/ 1"EMBEDMENT IN CONCRETEBRACED WALL LINE(4-FT)(4-FT)(4-FT)BRACEDWALL LINE(4-FT)(4-FT)(4-FT)BRACEDWALL LINE(4-FT)(3.5-FT)BRACED WALL LINE (4-FT)(4-FT)(4-FT) (5-FT)(5-FT) BRACED WALL LINE(9-FT)(12-FT) BRACED WALL LINE(3-FT) BRACED WALL LINE (3-FT)(4-FT)BRACEDWALL LINE(4-FT)(3.2-FT)PROVIDE TOP & BOTTOM OF WALLCONNECTIONS SHOWN FORBRACED WALL PANELS ALONGINDICATED PORTION OF WALLBRACEDWALL LINEBRACEDWALL LINE(4-FT)(6-FT)ONE SIDED(2.6-FT)(2.5-FT)(4-FT)(4-FT)CONSTRUCT GARAGEPORTAL FRAME ASSHOWN IN 4/S1(4-FT)BRACEDWALL LINE(3-FT)(3-FT)BRACED WALL LINE(3-FT) BRACED WALL LINE (6-FT) (3-FT) BRACEDWALL LINE(8-FT) BRACED WALL LINE(2.6-FT)BRACEDWALL LINE(4-FT)(7.5-FT)PROVIDE TOP OF WALLCONNECTIONS SHOWN FORBRACED WALL PANELS ALONGINDICATED PORTION OF WALL(8-FT)CONTINUEHOLDOWN ASSHOWN IN 5/S1 MAIN FLOOR1' -8 1/4"UPPER PLATE20' -7 1/4"T.O. FOUNDATION0' -0"T.O. FOUNDATION0' -0"MAIN PLATE10' -9 3/8"MAIN PLATE10' -9 3/8"UPPER FLOOR12' -6 1/8"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"UPPER FLOOR PLATE HEIGHT8' - 1 1/8"VINYL BOARD& BATTEN TYP. @ FRONTSEE COLUMN DETAILSHEET A-501ALUMINUM SOFFIT& FASCIA TYP.VINYL SIDING TYP.6" SMARTSIDE TRIMTYP. @ FRONT4 BD. 6" PLANKSSTYLE SHUTTERS 6" BUMPED OUT LOUVERW/ CORBELS3' - 6"CULTURED STONEW/ CONCRETE CAPADDRESS STONE 6" SMARTSIDE FRIEZE BOARD @ FRONT TYP.6" SMARTSIDE STORY BOARD TYP. @ FRONT4" SMARTSIDE WINDOW & DOOR TRIM TYP @ FRONT8" 12"8" 12"7" / 12"4" / 12"GARAGE PLATE HEIGHT10' - 9 3/8"24" RETURNS TYP.8" / 12"8" / 12"7" 12"6" 12"7" / 12"ALUMINUM SOFFIT& FASCIA TYP.VINYL SIDING &CORNERS TYP.8" 12"7" / 12"6" / 12"7" 12"24" RETURNS TYP.7" 12"4" 12"8" / 12"8" / 12"7" / 12"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:7/27/2021 10:25:15 AMTHE ALI & WARSAME RESIDENCEL17, B1 -KNOB HILL 2ND ADDITION______ 178TH STREET WESTLAKEVILLE, MN 55044A-201OTT2446.23.21 CB1586139611177.27.21 CB6.22.21 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4099THE MADISON1/4" = 1'-0"A-2011FRONT ELEVATIONSHEET INDEXSHEET NUMBER SHEET NAMEA-201 ELEVATIONSA-401 FOUNDATIONA-402 LOWER FLOORA-403 MAIN FLOORA-404 UPPER FLOORA-501 SECTIONS - SCHEDULES - ROOF PLAN1/8" = 1'-0"A-2012LEFT ELEVATION1/8" = 1'-0"A-2013REAR ELEVATION1/8" = 1'-0"A-2014RIGHT ELEVATION 20' - 6"10' - 0"0' - 2"18' - 6"30' - 6"49' - 0"1' - 4 1/2"8' - 3" M.O.0' - 4 1/2"2' - 1 1/2"16' - 3" M.O.2' - 1 1/2"0' - 4"0' - 4"*ALL DIMENSIONS ARE TO EXTERIOR OF CONCRETE, NOT INSULATION2" FOAM INSULATIONBETWEEN WALL & SLAB42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY57' - 0"1' - 0"5' - 10"19' - 4"6' - 10"38' - 2"12' - 0"42' - 0"7' - 0"49' - 0"2' - 0"21' - 6"23' - 6"21' - 6"12' - 0"57' - 0"22' - 4"22' - 8"15' - 10"6' - 10"17' - 7 1/4"3' - 10 3/4"3' - 10 3/4"12' - 9 1/4"3' - 9 1/2"8' - 5 1/4"29' - 9 1/4"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.6' - 3 1/4"15' - 2 3/4"8' - 3 1/4"14' - 4 3/4"ANCHOR BOLTS ON EACH SIDE OF BEARING POINT ANCHOR BOLTS ON EACH SIDE OF BEARING POINT 7'-8"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.*ALL DIMENSIONS ARE TO EXTERIOR OF CONCRETE, NOT INSULATION:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 10"(W) POUREDCONCRETE FOUND. WALL W/4" x 8" EXTERIOR LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.LEAVE A 12" GAP IN THE FOOTINGFOR PLUMBING11' - 6"14' - 0"16' - 6":WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:7/27/2021 10:25:16 AMTHE ALI & WARSAME RESIDENCEL17, B1 -KNOB HILL 2ND ADDITION______ 178TH STREET WESTLAKEVILLE, MN 55044A-401OTT2446.23.21 CB1586139611177.27.21 CB6.22.21 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4099THE MADISON1/4" = 1'-0"A-4011FOUNDATION PLAN UP 16RUNEXCAVATEDFURNACESUMPW. H.15' - 10"6' - 10"20' - 6"10' - 0"18' - 6"30' - 6"49' - 0"12' - 0"38' - 2"6' - 10"1' - 4 1/2"8' - 3" M.O.0' - 4 1/2"2' - 1 1/2"16' - 3" M.O.2' - 1 1/2"1' - 0"5' - 10"BEDROOM #523' - 6"21' - 6"12' - 0"21' - 6"2' - 0"SET ON 3X SILL2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.0' - 4"0' - 4"*ALL DIMENSIONS ARE TO OUTSIDE OF THE CONCRETE/ SHEATHING 19' - 4"22' - 8"5' - 6"12' - 4"22/4 x 6/8R.O. 2' -6" x 6' -11"4' VANITYF. D.MECHANICALBATHUNEXCAVATEDFAMILY ROOM12' - 0"30' - 0"CO DET.SMOKEDET.SMOKEDET.42' - 0"INSULATE BETWEEN WALL & SLAB22' - 4"6' - 6"10' - 0"7' - 0"7' - 0"4' - 10"6' - 8"21' - 6"16' - 8"2-2x102-9 1/2" LSLDROPPED2-9 1/2" LSL3-9 1/2" LVL W/2 TRIMMERS 4' - 6"5' - 10"9' - 0"17' - 10"3' - 8"3' - 8"13' - 0"4' - 0"7' - 4"8' - 0"ANCHOR BOLTS ON EACH SIDE OF BEARING POINT ANCHOR BOLTS ON EACH SIDE OF BEARING POINT 7' - 3"1' - 11"7' - 6"4' - 0" B.W.P.3' - 0" B.W.P.2' - 8" B.W.P.3-2x6*ALL DIMENSIONS ARE TO OUTSIDE OF THE CONCRETE/ SHEATHING 7' - 0"42' - 0"49' - 0"18" FLOOR TRUSSESPER MFG. SPACING18" FLOOR TRUSSESPER MFG. SPACING2x6STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.AIR EX.224-48-2448 SLR.O. 8' -0" x 4' -0"H.H. 6' -10"104836 PICR.O. 4' -0" x 3' -0"H.H. 1' -8 1/4"126048 SLR.O. 5' -0" x 4' -0"H.H. 6' -10"42/8 x 6/8R.O. 2' -10" x 6' -11"42/8 x 6/8R.O. 2' -10" x 6' -11"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES3' x 4' F.G.SHWR W/SURROUNDCLOSET11' - 6"14' - 0"16' - 6"18" FLOOR TRUSSESPER MFG. SPACING57' - 0"57' - 0"XXXX96/0 x 6/8 SLIDER6' - 0"6' - 0"324-48-2460 SLR.O. 8' -0" x 5' -0"H.H. 6' -10"22/4 x 6/8R.O. 2' -6" x 6' -11"32/6 x 6/8R.O. 2' -8" x 6' -11"MECHANICAL CHASE ABOVE 1/4" = 1'-0"A-4021LOWER FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:7/27/2021 10:25:17 AMTHE ALI & WARSAME RESIDENCEL17, B1 -KNOB HILL 2ND ADDITION______ 178TH STREET WESTLAKEVILLE, MN 55044A-402OTT2446.23.21 CB1586139611177.27.21 CB6.22.21 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4099THE MADISON2-2x103 Trimmers3-16" LVL2-9 1/2" LSL4 Trimmers6" hole for HVACallowed midspan, seebeam calc for details.5x5 PSL5x5 PSL UP 17RDN 16RDN 3RDN 3R16' - 6"14' - 0"11' - 6"OFFICESINKDW85/0 x 6/8 FULL VIEWR.O. 5' -2" x 6' -11"18' - 6"30' - 6"20' - 6"10' - 0"49' - 0"2' - 3"16' - 0"2' - 3"0' - 6"8' - 0"1' - 6"11' - 1"7' - 5"4" CONCRETE SLAB, SLOPETOWARDS DOORS5/8" TYPE X GYP. BD. ALL COMMONWALLS & CEILING IF FLOOR ABOVEGARAGE PLATE HEIGHT TOMATCH MAIN FLOOR UNLESS NOTED OTHERWISE1116' x 7' O.H. GARAGE DOOR52/8 x 6/8 FIRE RATEDR.O. 2' -10" x 6' -10 1/4"16' - 0"7' - 0"23' - 0"42' - 0"7' - 0"6' - 0"8' - 11"4' - 1"108' x 7' O.H. GARAGE DOORGARAGE23' - 0"KNEE WALL W/ 14" SPINDLES @ 6' -10" H.H.ABOVE LANDINGR-38 MIN. INSULATIONIN FLOOR ABOVESEE COLUMN DETAILSHEET A-5012' - 0"21' - 6"12' - 0"38' - 0"6' - 0"1' - 0"4' - 6"5' - 10"0' - 10"7' - 10"24" CANT. ABOVE 4' - 1 1/4"4' - 0"3' - 2"2' - 6"22/4 x 6/8R.O. 2' -6" x 6' -11"22/4 x 6/8R.O. 2' -6" x 6' -11"22/4 x 6/8R.O. 2' -6" x 6' -11"36" REFMUD ROOMPOWDERCLOSETKITCHENDINING0' - 4 1/2" TYP.GAS F.P.EQEQ63/0 x 6/8 W/ 12" D.S. SL'S11' - 0"12' - 0"6' - 0"6' - 0 1/2"3' - 5"11' - 0"7' - 1"16' - 6"5' - 6"0' - 6"PORCHPED. SINK0' - 10"10' - 3"12' - 0"21' - 6"23' - 6"GREAT ROOMFOYER12' - 10"3' - 8"3' - 8"17' - 10"2' - 0"19' - 0"5' - 0"GIRDER TRUSS FLOOR GIRDER OR2-11 7/8" LVL2-11 7/8" LSL 2-2x12 2-2x8 DROPPED 2-2x10 W/2 TRIMMERS 2-9 1/2" LSL2-2x10 2-9 1/2" LSL CONT. W/2 TRIMMERS EA. SIDE2-9 1/2" LSL2-2x105' - 11 1/4"4' - 2"7' - 2"0' - 10"5' - 2"6' - 0"4' - 10"5x5 PSL5x7 PSL3-2x6 11' - 2"5' - 0"2' - 10"3' - 10"2' - 2"16' - 0"(5) 16" SH.4' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.B.W.P.2' - 10"4' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.B.W.P.2' - 8"B.W.P.2' - 6"4' - 0" B.W.P.4' - 0" B.W.P.2' - 3" B.W.P.2' - 3" B.W.P.2x620" FLOOR TRUSSESPER MFG. SPACINGGIRDER TRUSS36" COOKTOP W/ WOOD HOOD ABOVE PAINTED CABINETS 12" FLUSH SANCK BARR & SH. @ 68"BENCH W/HOOKSPORTAL FRAME W/ HOLD-DOWNS PORTAL FRAME W/ HOLD-DOWNS OVEN /MICRO2-2x10 FLUSH5' - 0"6' - 2"32/6 x 6/8R.O. 2' -8" x 6' -11"11' - 6"1' - 2"3' - 10"2-9 1/2" LSL2-2x10 2-2x10 R & SH. @ 68"TECH TUBE OVER FIREPLACE 10"x10" GYP. BD SOFFIT3-2X6KNEE WALL W/14" SPINDLES 4' - 0"6' - 0"20" FLOOR TRUSSESPER MFG. SPACING20" FLOOR TRUSSESPER MFG. SPACING20" FLOOR TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.57' - 0"22' - 0"57' - 0"FIREPLACE SET12" A.F.F.TILE SURROUND W/ MANTEL 36" TALL BUILT INW/ 2 FLOATINGSHELVES36" TALL BUILT INW/ 2 FLOATINGSHELVES121-42-2160 SLR.O. 7' -0" x 5' -0"H.H. 6' -10"114860 PICR.O. 4' -0" x 5' -0"H.H. 12' -10"13P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"13P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"42424 AWN FIXEDR.O. 2' -0" x 2' -0"H.H. 6' -10"42424 AWN FIXEDR.O. 2' -0" x 2' -0"H.H. 6' -10"94242 SLR.O. 3' -6" x 3' -6"H.H. 7' -2"BOTTOM OF WINDOWFRAMED @ 44" A.F.F.PANTRYCS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTESINSULATE GARAGE WALLS & CEILING 13P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"13P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"96/0 x 6/8 SLIDER6' - 6"5' - 0"7' - 0"7' - 0"6' - 9"9' - 9"3.5:12 VAULT LINE 13P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"3.5:12 13P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"B.W.P TO BE UPDATED WHEN PLAN IS FINISHED4 SEASONPORCH49' - 0"MFG. ROOF TRUSSES@ 24" O.C.96/0 x 6/8 SLIDERFRAME BOX FOR CHANDELIERMECHANICAL CHASE 1/4" = 1'-0"A-4031MAIN FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:7/27/2021 10:25:17 AMTHE ALI & WARSAME RESIDENCEL17, B1 -KNOB HILL 2ND ADDITION______ 178TH STREET WESTLAKEVILLE, MN 55044A-403OTT2446.23.21 CB1586139611177.27.21 CB6.22.21 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4099THE MADISON2-9 1/2" LSL2-2x102 Trimmers2-2x10 Cont.2-2x102-14" LVL DN 17RLOFT42' - 0"8' - 4 1/8"17' - 11 7/8"8' - 8"7' - 0"CO DET.SMOKEDET.SMOKEDET.SMOKEDET.ATTICACCESS12' - 0"7' - 0"23' - 0"42/8 x 6/8R.O. 2' -10" x 6' -11"32/6 x 6/8R.O. 2' -8" x 6' -11"8'-10" VANITY22/4 x 6/8R.O. 2' -6" x 6' -11"3.5:12BEDROOM #4BEDROOM #3CLOSETCLOSETBATHEN SUITEOWNER'S SUITE22/4 x 6/8R.O. 2' -6" x 6' -11"22/4 x 6/8R.O. 2' -6" x 6' -11"40' - 0"36' - 6"1' - 6"2' - 0"40' - 0"KNEE WALL W/14" SPINDLES 17' - 10"3' - 8"3' - 8"14' - 10"4' - 6"5' - 10"31' - 8"42/8 x 6/8R.O. 2' -10" x 6' -11"32/6 x 6/8R.O. 2' -8" x 6' -11"22/4 x 6/8R.O. 2' -6" x 6' -11"3.5:122-2x102-2x102-9 1/2" LSL2-2x102-2x102-2x102-2x102-2x1042' - 0"11' - 0"8' - 8 1/4"16' - 9 3/4"6' - 0"6' - 0"3' - 5"3' - 7"2' - 6"20' - 6"21' - 6"18' - 6"KNEE WALL W/14" SPINDLES 11' - 2"3' - 0 1/4"5' - 2 3/4"3' - 4"8' - 9"5' - 0"6' - 5"5' - 3 1/4"3' - 1"1' - 8"1' - 3"0' - 11 3/4"4' - 1"2' - 7"11' - 2"15' - 4"4' - 3"2' - 3"6' - 8"3' - 4"10' - 2"12' - 3"3' - 9"2' - 6"11' - 5"5' - 11"6' - 2"GLASS PANEL 3' - 0" B.W.P.3' - 0" B.W.P.3' - 0" B.W.P.3' - 0" B.W.P.3' - 0" B.W.P.3' - 0" B.W.P.3' - 0" B.W.P.3' - 0" B.W.P.3' - 0" B.W.P.3' - 0" B.W.P.3' - 0" B.W.P.SMOKEDET.42/8 x 6/8R.O. 2' -10" x 6' -11"FOLDING COUNTEROPEN TO BELOW 10' - 2"3' - 5"2' - 0"6' - 2"4' - 11"5' - 0"32/6 x 6/8R.O. 2' -8" x 6' -11"42/8 x 6/8R.O. 2' -10" x 6' -11"R & SH. @ 68"22/4 x 6/8R.O. 2' -6" x 6' -11"5' TUB/SHWR(5) 16" SH.3' - 2"60" F.G. BASEW/ C.T. WALLS12/4 SHWR DR.0' - 6"3'x5' WHIRLPOOLTUB (1) SHAMPOO SHELF22/4 x 6/8R.O. 2' -6" x 6' -11"3' LINENR & SH. @ 68"R & SH. @ 68"R & SH. @ 68"SMOKEDET.BEDROOM #23' - 0" B.W.P.2x62-2x10VAULT LINE 3-2x6GIRDER TRUSS3-2x6CLOSETLAUNDRYMFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.L.T.324-48-2460 SLR.O. 8' -0" x 5' -0"H.H. 6' -10"126048 SLR.O. 5' -0" x 4' -0"H.H. 6' -10"83648 PIC. TEMPR.O. 3' -0" x 4' -0"H.H. 6' -10"126048 SLR.O. 5' -0" x 4' -0"H.H. 6' -10"63636 SLR.O. 3' -0" x 3' -0"H.H. 6' -10"126048 SLR.O. 5' -0" x 4' -0"H.H. 6' -10"73648 CSMT ER.O. 3' -0" x 4' -0"H.H. 6' -10"94242 SLR.O. 3' -6" x 3' -6"H.H. 6' -10"52424-3 AWN FIXEDR.O. 6' -0" x 2' -0"H.H. 6' -10"DRYERWASHER6' VANITY2x6CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES1'-6" LINENTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:7/27/2021 10:25:19 AMTHE ALI & WARSAME RESIDENCEL17, B1 -KNOB HILL 2ND ADDITION______ 178TH STREET WESTLAKEVILLE, MN 55044A-404OTT2446.23.21 CB1586139611177.27.21 CB6.22.21 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4099THE MADISON1/4" = 1'-0"A-4041UPPER FLOOR PLAN 1' - 5"0' - 9 1/2"2x4 @ BOTTOM1x3 TYP.2x22x4 @ TOPSMOOTH LPSMARTSIDE TYP.SOFFIT1' - 9 1/2"1' - 0"FRONTSIDETOP VIEW1' - 5"0' - 9 1/2"FRAMING4x4 POSTWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALER6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETRT'D 2x8 SILL PLATEW/ CLOSED CELL ROLLSILL SEALERGRADEGRANULAR FILL4" DRAIN TILEW/ SILT SOCK1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOORLOWER PLATE HEIGHT 8' - 2"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.VERIFY FLOOR SYSTEMWITH FLOOR PLANSUPPER FLOOR PLATE HEIGHT8' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.3/4" T&GSUBFLOOR6 MIL. V.B.2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.1/2" OSBSHEATHINGTYVEK (OR EQUAL)ROLL HOUSE WRAPSIDING, VERIFYW/ ELEVATIONS5/8" GYP. BD.5/8" GYP. BD.VENTED ALUMINUMSOFFIT PANELSICE & WATER GUARDFROM EAVE TO 2'-0"MIN. OVER STRUCTUREVENT CHUTES & WIND WASH@ EACH TRUSS SPACEASPHALT SHINGLES W/15# ROLL FELT UNDER1/2" OSB ROOF SHEATHINGMFG. ROOFTRUSSES @ 24" O.C.ATTIC VENTINGAS PER CODER-49 MIN. BLOWNATTIC INSULATIONALUMINUM FASCIA W/2x6 SUB FASCIAALUMINUMDRIP EDGERIM JOISTRIM JOISTR-20 MIN. SPRAYFOAM INSULATION,COVER FOUNDATION WALLGMX THERMAL DRAINAGE BOARD(R-10) INSULATIONDRYVIT INSULATIONPROTECTION FROM SIDINGTO 6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITH OUTSIDE OF SHEATINGR-20 MIN. SPRAYFOAM INSULATION6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"5000 PSI CONCRETE@ ALL FOOTINGS2" FOAMBOARD(R-10) INSULATION4" DRAIN TILEW/ SILT SOCKWATER PROOF COATING FROM FOOTING TOSILL SEALERWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESINSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONINSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITHOUTSIDE OF SHEATHINGANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" OSBSHEATHINGRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESTOOP, FLASH AS REQ'DAT HOUSE WALLPOUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERSIDING, VERIFYW/ ELEVATIONSTYVEK (OR EQUAL) ROLL HOUSE WRAP0' - 2"FROM SHEATHING TOOUTSIDE OF FOUNDATIONANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION5/8" TYPE 'X' GYP BOARD,TAPE & MUD ALL SEAMSRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESLAB, FLASH AS REQ'DAT HOUSE WALL0' - 4"POUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERVERIFY FLOOR SYSTEMWITH FLOOR PLANS0' - 8"FASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP.MIN. 3/8" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).MIN. 1000 LB HOLD-DOWNDEVICE (EMBEDDED INTOCONCRETE & NAILEDINTO FRAMING)FRONT ELEVATIONMIN. FOOTING SIZE UNDER OPENING IS12" X 12". A TURNED DOWN SLAB SHALLBE PERMITTED AT DOOR OPENINGS.MIN. (1) 5/8" DIA. ANCHOR BOLDINSTALLED PER R403.1.6 W/2" X 2" X 3/16" PLATE WASHER.MIN. REINFORCING OF FOUNDATION,ONE #4 BAR TOP & BOTTOM OFFOOTING. LAP BARS 15" MINIMUM.MIN. (2) 4200 LB STRAP-TYPE HOLD-DOWNS (EMBEDDED INTO CONCRETEAND NAILED INTO FRAMING)MIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 3/8" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INALL FRAMING (STUDS, BLOCKING AND SILLS) TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED10' - 0" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTALALL DUCT WORK & PLUMBING TO REMAIN ABOVE INSULATIONTYVEK OR EQUALHOUSE WRAP5/8" TYPE 'X'GYP. BD., TAPE &MUD ALL SEAMS1" RIGID INSULATION3/4" T&G SUBFLOORR-30 MIN.BLOWN INSULATIONFLOOR TRUSS2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.TRT'D SILL PLATEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSSLEEVE EVERY10'-0" MIN.6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODE5000 PSI CONCRETE@ ALL FOOTINGS18" OVERHANGS & 12" RAKES TYP.STANDARD ENERGY HEELS @ 4:12 & 7:12W/ 6:12 & 8:12 TO MATCH FASCIA LINES 8 ROOF VENTS REQUIRED 2 ROOF VENTS REQUIRED7" / 12"7" / 12"8" / 12"8" / 12"4" / 12"8" / 12"8" / 12"6" / 12"7" / 12"7" / 12"1 ROOF VENT REQUIRED THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:7/27/2021 10:25:20 AMTHE ALI & WARSAME RESIDENCEL17, B1 -KNOB HILL 2ND ADDITION______ 178TH STREET WESTLAKEVILLE, MN 55044A-501OTT2446.23.21 CB1586139611177.27.21 CB6.22.21 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4099THE MADISON1/2" = 1'-0"A-5012TYP. COLUMNWINDOW SCHEDULETYPE MARK MANUFACTURER MODEL COUNT UNIT ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT1 WINDSOR NEXT DIMENSION 1 21-42-2160 SL 7' - 0" 5' - 0" 6' - 10"2 WINDSOR NEXT DIMENSION 1 24-48-2448 SL 8' - 0" 4' - 0" 6' - 10"3 WINDSOR NEXT DIMENSION 2 24-48-2460 SL 8' - 0" 5' - 0" 6' - 10"4 WINDSOR NEXT DIMENSION 2 2424 AWN FIXED 2' - 0" 2' - 0"6' - 10"5 WINDSOR NEXT DIMENSION 1 2424-3 AWN FIXED 6' - 0" 2' - 0" 6' - 10"6 WINDSOR NEXT DIMENSION 1 3636 SL 3' - 0" 3' - 0" 6' - 10"7 WINDSOR NEXT DIMENSION 1 3648 CSMT E 3' - 0" 4' - 0" 6' - 10"8 WINDSOR NEXT DIMENSION 1 3648 PIC. TEMP 3' - 0" 4' - 0"6' - 10"9 WINDSOR NEXT DIMENSION 2 4242 SL 3' - 6" 3' - 6" VARIES10 WINDSOR NEXT DIMENSION 1 4836 PIC 4' - 0" 3' - 0" 1' - 8 1/4"11 WINDSOR NEXT DIMENSION 1 4860 PIC 4' - 0" 5' - 0" 12' - 10"12 WINDSOR NEXT DIMENSION 4 6048 SL 5' - 0" 4' - 0" 6' - 10"13 WINDSOR NEXT DIMENSION 6 P4260/A24 T 3' - 6" 7' - 0" 8' - 0"3/8" = 1'-0"A-5013TYP. WALL SECTIONROOM FINISHED SCHEDULEFLOOR ROOM NAME FLOORING AREA CEILING HEIGHT COMMENTSLOWER FLOOR BEDROOM #5 CARPET 126 SF 8' - 2" .LOWER FLOOR FAMILY ROOM CARPET 746 SF 8' - 2" .LOWER FLOOR STAIRWAY CARPET 72 SF 8' - 2"LOWER FLOOR CLOSET CARPET 53 SF 8' - 2"LOWER FLOOR MECHANICAL UNFINISHED 131 SF 8' - 2" MECHANICALS MAY VERYLOWER FLOOR BATH VINYL 48 SF 8' - 2" .MAIN FLOOR 4 SEASON PORCH 150 SF 9' - 1 1/8" VAULTEDMAIN FLOOR OFFICE CARPET 125 SF 9' - 1 1/8" .MAIN FLOOR GARAGE CONCRETE 644 SF 10' - 9 3/8"MAIN FLOOR PORCH CONCRETE 111 SF 9' - 1 1/8" .MAIN FLOOR MUD ROOM VINYL 60 SF 9' - 1 1/8" .MAIN FLOOR POWDER VINYL 29 SF 9' - 1 1/8" .MAIN FLOOR CLOSET VINYL 30 SF 9' - 1 1/8" .MAIN FLOOR KITCHEN WOOD 172 SF 9' - 1 1/8" .MAIN FLOOR DINING WOOD 191 SF 9' - 1 1/8" .MAIN FLOOR PANTRY WOOD 18 SF 9' - 1 1/8"MAIN FLOOR GREAT ROOM WOOD 254 SF 9' - 1 1/8" .MAIN FLOOR FOYER WOOD 153 SF 9' - 1 1/8" .UPPER FLOOR LOFT CARPET 304 SF 8' - 1 1/8" .UPPER FLOOR BEDROOM #4 CARPET 142 SF 8' - 1 1/8" .UPPER FLOOR BEDROOM #3 CARPET 132 SF 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 24 SF 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 24 SF 8' - 1 1/8" .UPPER FLOOR OWNER'S SUITE CARPET 250 SF 8' - 1 1/8" VAULTEDUPPER FLOOR BEDROOM #2 CARPET 157 SF 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 64 SF 8' - 1 1/8" .UPPER FLOOR STAIRS CARPET 78 SF 8' - 1 1/8"UPPER FLOOR EN SUITE L.V.T. 135 SF 8' - 1 1/8" .UPPER FLOOR BATH VINYL 61 SF 8' - 1 1/8" .UPPER FLOOR LAUNDRY VINYL 66 SF 8' - 1 1/8"DOOR SCHEDULETYPE MARK DOOR SIZE COUNT ROUGH WIDTH ROUGH HEIGHT COMMENTS1 2/4 SHWR DR. 12 2/4 x 6/8 11 2' - 6" 6' - 11"3 2/6 x 6/8 5 2' - 8" 6' - 11"4 2/8 x 6/8 6 2' - 10" 6' - 11"5 2/8 x 6/8 FIRE RATED 1 2' - 10" 6' - 10 1/4"6 3/0 x 6/8 W/ 12" D.S. SL'S 18 5/0 x 6/8 FULL VIEW 1 5' - 2" 6' - 11"9 6/0 x 6/8 SLIDER 310 8' x 7' O.H. GARAGE DOOR 111 16' x 7' O.H. GARAGE DOOR 13" MIN. ABS OR PVC GASTIGHT PIPE FROM SUBSLAB TO MIN.12" ABOVE ROOF, MUST BE RUN THRU CONDITIONED SPACE.PIPE CAN BE CONNECTED TO SUMP SYSTEM OR HAVE"T" FITTING (MIN. 10'-0" EA. WAY) IN GRAVEL UNDER SLAB.END OF PIPE MUST BE MIN. 10'-0" AWAY FROM ANY WINDOW OROTHER OPENING THAT IS LESS THAN 2'-0" BELOW END OF PIPE. END OF PIPE MUST ALSO BE MIN. 10'-0" AWAY FROM ANYWINDOW OR OTHER OPENING IN ADJOINING OR ADJACENT BUILDINGS.SUFFICIENT SPACE MUST BE LEFT AROUND PIPE IN ATTIC SPACETO ADD FAN. SPACE MUST BE MIN. ∅24" CENTERED ON AXIS OFPIPE W/ MIN. 3'-0" VERTICAL SPACE.A SINGLE PIPE CAN BE USED IF ALL SOIL GASES IN DWELLING CANFLOW FREELY BETWEEN ALL LEVELS OF FOUNDATION. THIS INCLUDESINTERIOR FOOTINGS & OTHER BARRIERS IF AIRFLOW HAS BEEN ESTABLISHED.LABEL THE VENT PIPE AT LEAST ONCE PER FLOOR AND IN ACCESSIBLE ATTICSWITH "RADON REDUCTION SYSTEM".ONE ELECTRICAL RECEPTACLE IS REQUIRED IN THE ATTIC NEARTHE VENT PIPE FOR OPT. FAN.:PASSIVE RADON SYSTEM:1/2" = 1'-0"A-5011TYP. WALKOUT SECTION1/2" = 1'-0"A-5014TYP. LOOKOUT SECTION1/2" = 1'-0"A-5015TYP. HOUSE/STOOP WALL1/2" = 1'-0"A-5016TYP. HOUSE/GARAGE WALL3/8" = 1'-0"A-5017METHOD PFH - PORTAL FRAME WITH HOLD-DOWNS1/2" = 1'-0"A-5018GARAGE CEILING1/2" = 1'-0"A-5019BEARING WALL SECTION1/8" = 1'-0"A-50110ROOF PLAN NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. New residential building permits WILL NOT be issued without this completed form. Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ Primary Contact: _________________________________________________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Description of Land Disturbing Activity: _____________________________________________________ NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___ If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an erosion and sediment control plan MUST be submitted with the residential building permit application. Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name of Person: ________________________________Company: _______________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: ________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots. No land disturbing activity may begin until a residential building permit has been issued. I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 * If awaiting a MPCA permit transfer, provide MPCA proof of transfer submittal e-mail along with this form to erosion@lakevillemn.gov “The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.” (NPDES Construction Stormwater Permit, MPCA) “The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA) X09/14/21 KP