Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LA196024 - Josh Jaeger - ELEC PERMIT APPLICATION
1264 Energy Lane 55108 (651) 842-9404 Colin Buechel All Energy Solar 667674 St. Paul MN Installation of a flush mount solar array on the roof of the residence X Colin Buechel COMPANY INFORMATION CLIENT INFORMATION SYSTEM DETAILS PROJECT-PAGE TITLE ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM PAGE NUMBER A3 REVISIONS LAST: 09/15/21 AH AZIMUTH ACCOUNT: 200010066108 PREMISE: 116742 METER: 1ND90305891 SITE MAP N JOSHUA JAEGER 19436 HILLDALE AVE LAKEVILLE, MN 55044 PO 47060 NOTES: 1. (26) ENPHASE IQ7A INVERTER(S) = 9.074kW AC 2. ARRAY 1: 180° AZIMUTH, 37° TILT (26) LG 385W = 10.01kW 3. ARRAY 2: (Array 2 Azimuth)° AZIMUTH, (Array 2 Tilt)° TILT ((Array 2 Panel Qty)) LG 385W = (Array 2 kW)kW 4. ARRAY 3: (Array 3 Azimuth)° AZIMUTH, (Array 3 Tilt)° TILT ((Array 3 Panel Qty)) LG 385W = (Array 3 kW)kW 5. ARRAY 4: (Array 4 Azimuth)° AZIMUTH, (Array 4 Tilt)° TILT ((Array 4 Panel Qty)) LG 385W = (Array 4 kW)kW NOTES: 1. LOCATION OF SERVICE PANEL AND ELECTRICAL EQUIPMENT ARE SHOWN. FINAL LOCATION MAY CHANGE 2. LOCATION OF SERVICE PANEL AND ADDITIONAL ELECTRICAL EQUIPMENT NOT DRAWN TO SCALE 3. PV INTERCONNECTION IS A SECONDARY INTERCONNECTION 4. AC DISCONNECT AND PRODUCTION METER IN READILY ACCESSIBLE LOCATION WITHIN 10' OF MAIN SERVICE METER/BI-DIRECTIONAL METER. 24/7 UNESCORTED KEYLESS ACCESS TO BE PROVIDED FOR UTILITY AC DISCONNECT, PV PRODUCTION METER, & BI-DIRECTIONAL METER. 5. PV EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690 AND POSTED WITH APPLICABLE WARNINGS, SIGNAGE, AND PLAQUES PER NEC 705-10, 690-17, & 690-64 (b)(5). 6. CIRCUITS: (2) CIRCUIT(S) OF 9 (20AMPS EACH) (1) CIRCUIT(S) OF 8 (15AMPS EACH) ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) ([Amps] (If Enphase. Based on 15 or 20A breakers)AMPS EACH) ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) ([Amps] (If Enphase. Based on 15 or 20A breakers)AMPS EACH) ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) ([Amps] (If Enphase. Based on 15 or 20A breakers)AMPS EACH) 1 2 3 4 5 6 CALL-OUTS: 1: SOLAR PANELS 2: INVERTERS 3: ENPHASE IQ COMBINER PANEL 4: UTILITY FUSED AC DISCONNECT 5: PV PRODUCTION METER 6: BI-DIRECTIONAL METER 7: MAIN ELECTRIC SERVICE DISTANCESSOLAR PANELS - INVERTERS: 5' MAX INVERTERS - IQ COMBINER PANEL: 50' MAX IQ COMBINER PANEL - UTILITY FUSED AC DISCONNECT: 2' UTILITY FUSED AC DISCONNECT - PV PRODUCTION METER: 2' PV PRODUCTION METER - BI-DIRECTIONAL METER: 2' BI-DIRECTIONAL METER - MAIN ELECTRIC SERVICE: 5' LABELS LOCATED ON PV PRODUCTION METER, BI- DIRECTIONAL METER, AC DISCONNECT(S), INVERTER(S), AND APPROPRIATE LABELS ON MAIN ELECTRIC SERVICE. ALL LABELS ARE PERMANENT, WEATHERPROOF, AND DURABLE THERE ARE NO CLEARANCE ISSUES DUE TO OVERHEAD POWERLINES. <10'HILLDALE AVEARRAY 1 HOUSE AREA: 2,654 SQ FT AREA OF ARRAYS: 520 SQ FT 7 SETBACKS PER FIRE CODE 3'-0"18" COMPANY INFORMATION CLIENT INFORMATION SYSTEM DETAILS PROJECT-PAGE TITLE ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM PAGE NUMBER A4 REVISIONS LAST: 09/15/21 AH *DISTANCES NOT TO SCALE NOTES: 1. DESIGN MEETS NEC CODE AND SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690 AND POSTED WITH APPLICABLE WARNINGS, SIGNAGE, AND PLAQUES PER NEC 705-10, 690- 17, & 690-64 (b) (5) 2. SOLAR MODULES, INVERTERS, AND CORRESPONDING ELECTRICAL EQUIPMENT ARE LISTED. 3. INVERTERS ARE UL 1741 LISTED 4. PV INTERCONNECTION IS A SECONDARY INTERCONNECTION SYSTEM SIZE: 10.01kW DC MAXIMUM POWER: 9.074 kW AC OPERATING VOLTAGE: 120/240V MAXIMUM CURRENT: 37.7A ACCOUNT: 200010066108 PREMISE: 116742 METER: 1ND90305891 ELECTRICAL LINE DIAGRAM TO UTILITY JOSHUA JAEGER 19436 HILLDALE AVE LAKEVILLE, MN 55044 PO 47060 AC DC UTILITY FUSED AC DISCONNECT VISIBLE-OPEN TYPE, LOCKABLE, READILY ACCESSIBLE 1 PHASE, 60A, 120/240V SEE LABEL(S) 10, 14, 15, 16, 20, 35 ON FOLLOWING PAGES 2' EXISTING 5' MAX LINETAP INSIDE MAIN ELECTRICAL PANEL VIA UL-LISTED POLARIS LUGS 120/240V 200A RATED BUS 200A MAIN EATON LOAD PANEL SEE LABEL(S) 18 ON FOLLOWING PAGES50ADAKOTA ELECTRIC BI-DIRECTIONAL METER 120/240V, 1-PHASE, 3-WIRE SEE LABEL(S) 41, 42 ON FOLLOWING PAGES (26) LG 385Q1K-A6 10.01kW (26) ENPHASE IQ7A 120/240V (2) CIRCUIT(S) OF 9 (20A EA) (1) CIRCUIT(S) OF 8 (15A EA) ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) ([Amps] (If Enphase. Based on 15 or 20A breakers)A EA) ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) ([Amps] (If Enphase. Based on 15 or 20A breakers)A EA) ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) ([Amps] (If Enphase. Based on 15 or 20A breakers)A EA) LG LG385Q1K-A6 RATED POWER AT STC:385W VMP:37.40V IMP:10.30A VOC:43.70V ISC:10.86A MODULE DETAILS: (26) INVERTER DETAILS: ENPHASE IQ7A-72-2-US Rating: 349 W CEC Weighted Efficiency: 97 % Max DC Voltage: 58.V V Max AC Output Current: 1.45 A Nominal Voltage Range: 240V / 211-264V (1-Phase) Nominal Frequency: 60 Hz 50' MAX 3/4" EMT: (6) #10 THWN (1) #10 GROUND 2' MAX 3/4" EMT: (2) #8 THWN (1) #10 NEUTRAL (1) #10 GROUND [%]% VOLTAGE DROP [Trench distance]' MAX [Minimum 1]" PVC: (2) #[wire size] THWN (1) #10 NEUTRAL (1) #10 GROUND ENPHASE IQ COMBINER PANEL 120/240V 125A 1 PHASE PLACARD INDICATING "NO LOAD TO BE SERVED" SEE LABEL(S) 16, 18, 24 ON FOLLOWING PAGES 2' MAX 1" PVC: (2) #6 THWN (1) #6 NEUTRAL DAKOTA ELECTRIC PRODUCTION METER 120/240V, 200A WITH BYPASS 1-PHASE, 3-WIRE SEE LABEL(S) 21 ON FOLLOWING PAGES LINE/ TOP LOAD/ BOTTOM 2' MAX 1" PVC: (2) #6 THWN (1) #6 NEUTRAL COMPANY INFORMATION CLIENT INFORMATION SYSTEM DETAILS PROJECT-PAGE TITLE ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM PAGE NUMBER A5 REVISIONS LAST: 09/15/21 AH LABELS ARE WEATHERPROOF, DURABLE, PERMANENTLY MOUNTED, AND COMPLY WITH NEC 690 ACCOUNT: 200010066108 PREMISE: 116742 METER: 1ND90305891 LABELS JOSHUA JAEGER 19436 HILLDALE AVE LAKEVILLE, MN 55044 PO 47060 PHOTOVOLTAIC AC DISCONNECT MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: P H O T O V O L T A I C A C D I S C O N N E C T MAIN PHOTOVOLTAIC SYSTEM DISCONNECT CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED ! WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM WARNING: PHOTOVOLTAIC POWER SOURCE WARNING! ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM 16 13 15 41 42 14 5: EXPOSED DC CONDUIT, JUNCTION BOXES, ECT. 8: 10 HOUSE METER 21 PV PRODUCTION METER TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS 35 MAXIMUM DC VOLTAGE OF PV SYSTEM 7 PHOTOVOLTAIC DC DISCONNECT 6 ! POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. WARNING PV SYSTEM CIRCUIT BREAKER IS BACKFED CAUTION 36 37 UTILITY AC DISCONNECT 20 NOTE: LABELS ARE FOR GENERAL REFERENCE. NOT ALL LABELS ARE USED FOR EVERY INSTALLATION. INTERCONNECTION DISCONNECT SWITCH 17 COMPANY INFORMATION CLIENT INFORMATION SYSTEM DETAILS PROJECT-PAGE TITLE ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM PAGE NUMBER A6 REVISIONS LAST: 09/15/21 AH LABELS 2 LABELS ARE WEATHERPROOF, DURABLE, PERMANENTLY MOUNTED, AND COMPLY WITH NEC 690 ACCOUNT: 200010066108 PREMISE: 116742 METER: 1ND90305891 43 18 JOSHUA JAEGER 19436 HILLDALE AVE LAKEVILLE, MN 55044 PO 47060 CAUTION:MULTIPLE SOURCES OF POWER: N All Energy Solar www.allenergysolar.com (800) 620-3370 SOLAR ARRAY PV COMBINER PANEL HOUSE SERVICE DISCONNECT (GARAGE) MAIN PV DISCONNECTINTERCONNECTION DISCONNECT SWITCH 17 DUAL POWER SOURCE PHOTOVOLTAIC CIRCUIT Operating Voltage: 120/240 Maximum Current: 37.7 Amps Maximum Power: 9.074 KW MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC CONVERTER (IF INSTALLED) 22 24 NOTICEPV COMBINER PANEL ONLY NO LOADS EMERGENCY DISCONNECT SERVICE DISCONNECT 15 LG385Q1K-A6 About LG Electronics USA, Inc. LG Electronics is a global leader in electronic products in the clean energy markets by offering solar PV panels and energy storage systems. The company first embarked on a solar energy source research program in 1985, supported by LG Group’s vast experience in the semi-conductor, LCD, chemistry and materials industries. In 2010, LG Solar successfully released its first MonoX® series to the market, which is now available in 32 countries. The NeON® (previous MonoX® NeON), NeON®2, NeON®2 BiFacial won the “Intersolar AWARD” in 2013, 2015 and 2016, which demonstrates LG’s leadership and innovation in the solar industry. 385W 60 LG Solar’s NeON® R Prime is a powerful solar module that provides premium performance. The NeON® R incorporates a cell structure without electrodes on the front to maximize light utilization and enhance reliability. Providing added value for the customer beyond efficiency, this module features an enhanced warranty, outstanding durability, solid performance in real-world conditions and aesthetic design suitable for roofs. Enhanced Performance Warranty LG NeON® R has an enhanced performance warranty. After 25 years, LG NeON® R is guaranteed at least 92.5% of initial performance. Roof Aesthetics LG NeON® R has been designed with aesthetics in mind: the lack of any electrodes on the front creates an improved, modern aesthetic. 25-Year Limited Product Warranty The NeON® R covered by a 25-year limited product warranty. In addition, up to $450 of labor costs will be covered in the rare case that a module needs to be repaired or replaced. More Generation Per Square Meter The LG NeON® R has been designed to significantly enhance its output, making it efficient even in limited space. Features yrs25 Warranty When you go solar, ask for the brand you can trust: LG Solar LG385Q1K-A6 I-V Curves Certifications and Warranty Certifications* IEC 61215-1/-1-1/2 : 2016, IEC 61730-1/2 : 2016, UL 61730-1 : 2017, UL 61730-2 : 2017 ISO 9001, ISO 14001, ISO 50001 OHSAS 18001 Salt Mist Corrosion Test IEC 61701:2012 Severity 6 Ammonia Corrosion Test IEC 62716:2013 Module Fire Performance Type 2 (UL 61730) Fire Rating Class C (UL 790, ULC/ORD C 1703) Product Warranty 25 Years Output Warranty of Pmax Linear Warranty* *Improved: 1st year 98.5%, from 2-24th year: 0.25%/year down, 92.5% at year 25 1042.0 / 41.0 (Size of Short Side)320.0 / 12.61002.0 / 39.4 (Distance between Grounding & Mounting Holes) 175.0 / 6.9 1250.0 / 49.2 Cable Length 40.0 / 1.57 105.0 / 4.1220.0 / 8.616 - 8.0 x 3.0 / 0.3 x 0.1 Drain Holes 8 - Ø4.3 / 0.2 Grounding Holes 8 - 8.5 x 12.0 / 0.3 x 0.5 Mounting Holes Junction Box 1100.0 / 43.3 (Distance between Mounting Holes)1300.0 / 51.2 (Distance between Mounting Holes)1740.0 / 68.5 (Size of Long Side)Electrical Properties (NMOT) Model LG385Q1K-A6 Maximum Power (Pmax)[W]292 MPP Voltage (Vmpp)[V]35.3 MPP Current (Impp)[A]8.26 Open Circuit Voltage (Voc)[V]41.7 Short Circuit Current (Isc)[A]8.76 Operating Conditions Operating Temperature*[°C ]-40 ~ +85 Maximum System Voltage [V]1,000 Maximum Series Fuse Rating [A]20 Mechanical Test Load** (Front)[Pa/psf]5,400 Mechanical Test Load** (Rear)[Pa/psf]4,000 *The operating ambient temperature of these devices may exceed 40°C at full load for all wire sizes if is determined suitable in the field use application. **Based on IEC 61215-2 : 2016 (Test Load = Design Load x Safety Factor (1.5)) General Data Cell Properties (Material/Type)Monocrystalline/N-type Cell Maker LG Cell Configuration 60 Cells (6 x 10) Module Dimensions (L x W x H)1,740mm x 1,042mm x 40mm Weight 18.5 kg Glass (Material)Tempered Glass with AR Coating Backsheet (Color)Black Frame (Material)Anodized Aluminium Junction Box (Protection Degree)IP 68 with 3 Bypass Diodes Cables (Length)1,250mm x 2EA Connector (Type/Maker)MC 4/MC Temperature Characteristics NMOT*[ °C ] 44 ± 3 Pmax [%/°C]-0.29 Voc [%/°C]-0.24 Isc [%/°C] 0.04 *NMOT (Nominal Module Operating Temperature): Irradiance 800 W/m2, Ambient temperature 20°C, Wind speed 1 m/s, Spectrum AM 1.5 LG Electronics USA, Inc.Solar Business Division2000 Millbrook DriveLincolnshire, IL 60069 www.lg-solar.com Product specifications are subject to change without notice. LG385Q1K-A6.pdf 011821 © 2021 LG Electronics USA, Inc. All rights reserved. Electrical Properties (STC*) Model LG385Q1K-A6 Maximum Power (Pmax)[W]385 MPP Voltage (Vmpp)[V]37.4 MPP Current (Impp)[A]10.30 Open Circuit Voltage (Voc, 5%)[V]43.7 Short Circuit Current (Isc, 5%)[A]10.86 Module Efficiency [%]21.2 Power Tolerance [%]0 ~ +3 *STC (Standard Test Condition): Irradiance 1000 W/m², cell temperature 25°C, AM 1.5Measure Tolerance: 3%+_ + - + - 200W 400W 600W 800W 1000W Voltage [V]Current [A]12.0 10.0 8.0 6.0 4.0 2.0 0.0 0.0 10.05.0 20.015.0 30.025.0 45.040.035.0 Dimensions (mm/inch) Packaging Configuration Number of Modules per Pallet [EA]25 Number of Modules per 40' Container [EA]650 Number of Modules per 53’ Container [EA]850 Packaging Box Dimensions (L x W x H)[mm]1,790 x 1,120 x 1,227 Packaging Box Dimensions (L x W x H)[in]70.5 x 44.1 x 48.3 Packaging Box Gross Weight [kg]498 Packaging Box Gross Weight [lb]1,098 The high-powered smart grid-ready Enphase IQ 7A Micro™ dramatically simplifies the installation process while achieving the highest system efficiency for systems with 60-cell and 72-cell modules. Part of the Enphase IQ System, the IQ 7A Micro integrates with the Enphase IQ Envoy™, Enphase IQ Battery™, and the Enphase Enlighten™ monitoring and analysis software. The IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Enphase IQ 7A Microinverter To learn more about Enphase offerings, visit enphase.com Data SheetEnphase MicroinvertersRegion: AMERICAS High Power • Peak output power 366 VA @ 240 VAC and 295 VA @ 208 VAC Easy to Install • Lightweight and simple • Faster installation with improved, lighter two-wire cabling • Built-in rapid shutdown compliant (NEC 2014 & 2017) Efficient and Reliable • Optimized for high powered 60-cell and 72-cell modules • Highest CEC efficiency of 97% • More than a million hours of testing • Class II double-insulated enclosure • UL listed Smart Grid Ready • Complies with advanced grid support, voltage and frequency ride-through requirements • Envoy and Internet connection required • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) 1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility.2. CEC peak power tracking voltage range is 38 V to 43 V.3. Maximum continuous input DC current is 10.2A. 4. Voltage range can be extended beyond nominal if required by the utility.5. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com © 2019 Enphase Energy. All rights reserved. Enphase, the Enphase logo, Enphase IQ 7A, Enphase IQ Battery, Enphase Enlighten, Enphase IQ Envoy, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subject to change. 2019-11-07 INPUT (DC)IQ7A-72-2-US Commonly used module pairings¹295 W–460 W + Module compatibility 60-cell, 66-cell, and 72-cell PV modules Maximum input DC voltage 58 V Power point tracking voltage range²18 V–58 V Min/Max start voltage 30 V / 58 V Max DC short circuit current (module Isc)³15 A Overvoltage class DC port II DC port backfeed current 0 A PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT (AC)@ 240 VAC @ 208 VAC Peak output power 366 VA 295 VA Maximum continuous output power 349 VA 290 VA Nominal (L-L) voltage/range4 240 V / 211–264 V 208 V / 183–229 V Maximum continuous output current 1.45 A (240 VAC)1.39 A (208 VAC) Nominal frequency 60 Hz Extended frequency range 47–68 Hz AC short circuit fault current over 3 cycles 5.8 Arms Maximum units per 20 A (L-L) branch circuit5 11 (240 VAC)11 (208 VAC) Overvoltage class AC port III AC port backfeed current 18 mA Power factor setting 1.0 Power factor (adjustable)0.85 leading ... 0.85 lagging EFFICIENCY @240 VAC @208 VAC CEC weighted efficiency 97.0 %96.5% MECHANICAL Ambient temperature range -40ºC to +60ºC Relative humidity range 4% to 100% (condensing) Connector type: DC (IQ7A-72-2-US)MC4 Dimensions (WxHxD)212 mm x 175 mm x 30.2 mm (without bracket) Weight 1.08 kg (2.38 lbs) Cooling Natural convection — No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environmental category / UV exposure rating NEMA Type 6 / outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring optionsCompatible with Enphase IQ Envoy Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA)UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer’s instructions. Enphase IQ 7A Microinverter