Loading...
HomeMy WebLinkAboutLA196680 - 17989 Gresford Ln Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov Nick Reimler CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ 7 Metro Heating and Air 612-590-2678 612-590-2678 609 150th Ave NE Ham Lake Mn 55304 MB004178 12/3/22 RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: 20195 Holyoke Avenue, Lakeville, MN 55044 952-985-4400  952-985-4499 fax www.lakevillemn.gov Sewer & Water Tie Card Address:________________________________________ Contractor:______________________________________ Permit Number:__________________________________ Final Date:________________ Street Drain-Tile:______ Size of Water Service: 1” Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME OF SEWER & WATER INSPECTION 1 7 SCALE: 1/4" = 1'-0" FRONT ELEVATION GENERAL NOTES: 1. ALL DOOR AND WINDOW HEADERS TO BE S.P.F. #2 OR BETTER, SEE PLANS FOR SIZES. 2. HOUSE TO BE BUILT PER CURRENT I.R.C. CODES. 3. VERIFY GRADES AND ADJUST FOUNDATION/FOOTING STEPS AS NEEDED. 4. SEE PLANS FOR CEILING HEIGHTS 5. 4' HIGH POURED FDN. WALLS STD. 6. FLOOR PLAN DIMENSIONS ARE TO FACE OF FRAMING AND FOUNDATION. 7. ALL TRADES & SUPPLIERS TO REVIEW & VERIFY INFORMATION PERTINENT TO THEIR WORK AND NOTIFY CONST. OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 8. NOTED CABINET SIZES ARE +/- AND TO BE FIELD VERIFIED. 9. TRADES TO VERIFY BASE AND TRIM SIZE PRIOR TO CONSTRUCTION. 10. ALL WALLS MORE THAN 10' H. TO BE S.P.F. #2 OR BETTER. 11. EXTERIOR ELEVATIONS ARE CONCEPTUAL ONLY: HOME SITE, FILL AND TOPOGRAPHY WILL DICTATE ACTUAL GRADES AND MAY VARY FROM THOSE SHOWN ON THE PLAN. 12. NOTE: SUBFLOOR JOINTS SHALL BE STAGGERED FROM FLOOR TRUSS OR JOIST JOINTS OF SHEET 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 13, BLOCK 6, SUMMERS CREEK17989 GRESFORD LN., LAKEVILLE"CHARLESTON" 1640 PLANMARK ELLIOTT HOMES5-12-21 SELECT 6-7-21 LOT CHNG. 7-6-21 PERMIT 8-17-21 REV. #1 9-30-21 REV. #2 SCALE: 1/8" = 1'-0" ROOF PLAN STONE TOTAL: 90.52 SQ. FT. (25.5%) TOTAL SQ. FT.: 337.39 MATERIAL CALCULATIONS: FRONT ELEV. LP LAP SIDING TOTAL: 37.05 SQ. FT. (11%) LP SHAKE TOTAL: 89.01 SQ. FT. (26.4%) LP TRIM / PANEL: 125.41 SQ. FT. (37.1%) STONE TOTAL: 132.12 SQ. FT. (4.2%) TOTAL SQ. FT.: 3,151.58 MATERIAL CALCULATIONS: ALL ELEV. LP LAP SIDING TOTAL: 1849.85 SQ. FT. (58.70%) LP SHAKE TOTAL: 89.01 SQ. FT. (2.81%) LP TRIM / PANEL: 424.80 SQ. FT. (13.47%) VINYL LAP SIDING TOTAL: 665.00 SQ. FT. (21.09%) SEE ROOF PLAN FOR ROOF PITCHES AND OVERHANGS 25'-3"CONC. PORCH 4" TRIM TYP. 6:12 6'-0"T.O. 3048 SH ALUM. SOFFIT & FASCIA 30 YR. ARCH. ASPHALT SHINGLES 2x OVER 6" TRIM 10" TRIM 12" LP COLUMN6'-0" LP SMARTSIDE LAP SIDING (4")9'-1 1/8"T.O. SUBFLR. T.O. PLATE 1'-8 1/4"T.O. FDN.9'-1 1/8"@ GARAGE T.O. PLATE 12 12 12 12 STAT. (BLACKENED) 2x OVER 10" TRIM1'-0"7'-2 1/2"T.O. 3048 SH STAT. (BLACKENED) 3:12 LP PANELLP PANEL12" CANT. 10" TRIM METAL CORNERS TYP. C/L LP SMARTSIDE SHAKE SIDING 2x OVER 6" TRIM LP PANELLP PANELT.O. FDN.7'-9"@ DORMER T.O. PLATE 10'-4"FP CHASE 24"x60" FALSE STONE CAP SADDLENOTE: SEE ROOF TRUSS LAYOUT FOR TRUSS DIRECTION AND GIRDER LOCATIONS PROVIDED BY MANUFACTURER PROVIDE ATTIC VENTILATION EQUAL TO 1/150th ATTIC AREA. IF 50% OR MORE IS PROVIDED IN UPPER PORTION OF THE ROOF AND REMAINDER IS PROVIDED IN SOFFIT VENTS, IT MAY BE REDUCED TO 1/300th ATTIC AREA. ICE AND WATER SHIELD 6'-0" IN FROM EAVES 1'-6" ON EACH SIDE OF VALLEY WHERE WALLS MEET ROOF ICE & WATER SHIELD SHOULD RUN UP WALL 1'-6" AND OUT FROM WALL 1'-6" NOTE: NOTE: NOTE: 8" 1'-0"2'-0"12:12 RIDGERIDGE 1'-0"1'-0"1'-6"6:126:123:126:1212:122'-0"2'-6"8"6'-0"1'-6"1'-6"1'-0"12:12 12:12 1'-6" Concept Approval ONLY Subject to Field Inspection Inspector Date 2020 MN Bldg Code 08/25/2021dmathews EXTERIOR ELEVATIONS ARE CONCEPTUAL ONLY: HOME SITE, FILL AND TOPOGRAPHY WILL DICTATE ACTUAL GRADES AND MAY VARY FROM THOSE SHOWN ON THE PLAN.2 7 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 13, BLOCK 6, SUMMERS CREEK17989 GRESFORD LN., LAKEVILLE"CHARLESTON" 1640 PLANMARK ELLIOTT HOMES5-12-21 SELECT 6-7-21 LOT CHNG. 7-6-21 PERMIT 8-17-21 REV. #1 9-30-21 REV. #2 OF SHEET SIDE ELEVATION SCALE: 3/16" = 1'-0" REAR ELEVATION SIDE ELEVATION SCALE: 3/16" = 1'-0" SCALE: 3/16" = 1'-0" T.O. PLATE 9'-1 1/8"T.O. SUBFLR. T.O. FDN.1'-8 1/4"@ GARAGE 9'-1 1/8"T.O. FDN.A/C UNIT 10" TRIM 10" TRIM METAL CORNERS 4" VINYL TRIM @ WDWS. & DOORS TYP. 12 6 T.O. PLATE 8" TRIM 12:12 12 6 12 3 7'-9"@ DORMER T.O. PLATE ALUM. SOFFIT & FASCIA SEE ROOF PLAN FOR PITCHES AND OVERHANGS 12:12 VERIFY GRADE STONE WHERE INDICATED 2'-0" LP SIDING LP SIDING TOTAL SQ. FT.: 1138.84 MATERIAL CALCULATIONS: LEFT ELEV. STONE TOTAL: 18.90 SQ. FT. (1.66%) LP TRIM / PANEL: 100.45 SQ. FT. (8.82%) LP LAP SIDING TOTAL: 676.49 SQ. FT. (59.40%) VINYL LAP SIDING TOTAL: 343.00 SQ. FT. (30.12%) VINYL SIDING PER SPECS (GABLE ONLY) T.O. PLATE 9'-1 1/8"T.O. SUBFLR. T.O. FDN.1'-8 1/4"6:12 METAL CORNERS 4" VINYL TRIM @ WDWS. & DOORS TYP. 10" TRIM 12" CANT. WFPWFPWFPWFP SEE ROOF PLAN FOR PITCHES AND OVERHANGS LP SIDING PER SPECS 12 12 12 12 ALUM. SOFFIT & FASCIA TRTD. DECK LEDGER TOTAL SQ. FT.: 481.14 MATERIAL CALCULATIONS: REAR ELEV. LP LAP SIDING TOTAL: 409.31 SQ. FT. (85.07%) LP TRIM / PANEL: 71.83 SQ. FT. (14.93%) LP SIDING PER SPECS @ THIS GABLE T.O. PLATE 9'-1 1/8"T.O. SUBFLR. T.O. FDN.1'-8 1/4"12:12 LP SIDING 12 6 10" TRIM 10" TRIM 12" CANT.METAL CORNERS 4" VINYL TRIM @ WDWS. & DOORS TYP. FP VENT SEE ROOF PLAN FOR PITCHES AND OVERHANGS 12:12ALUM. SOFFIT & FASCIA VINYL SIDING PER SPECS ROOF LINE BEYOND 12 6 SADDLE VERIFY GRADELP PANELTOTAL SQ. FT.: 1198.81 MATERIAL CALCULATIONS: RIGHT ELEV. STONE TOTAL: 22.70 SQ. FT. (1.90%) LP TRIM / PANEL: 127.11 SQ. FT. (10.60%) LP LAP SIDING TOTAL: 727.00 SQ. FT. (60.64%) VINYL LAP SIDING TOTAL: 322.00 SQ. FT. (26.86%) (GABLE ONLY) Secure door closed until deck is constructed with a separate permit. SCALE: 3/16" = 1'-0" FOUNDATION PLAN 3 7 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 13, BLOCK 6, SUMMERS CREEK17989 GRESFORD LN., LAKEVILLE"CHARLESTON" 1640 PLANMARK ELLIOTT HOMES5-12-21 SELECT 6-7-21 LOT CHNG. 7-6-21 PERMIT 8-17-21 REV. #1 OF SHEET A/C UNIT w/ BRACKET FURN F.D. WH MECH. / STORAGE WS F U T . 3 0 6 8FUT. 2668FUT. BDRM. #5 FUT. FAMILY ROOM R.I. BATHFUT. 36" V.CONC. H.B. H.B. 2" LEDGE TYP. TO PROVIDE ADD'L. SUPPORT FOR FILL FOR SLAB TYP. FND @ HOUSE / GARAGE 10" POURED CONC. W/ 4" LEDGE INSIDE 20X8 CONC. FTG. 2" FOAM SUMP H20 4" LEDGE2" FOAM TYP. FND @ STOOP 10" POURED CONC. W/ 4" LEDGE INSIDE 20X8 CONC. FTG. UNEXCAVATED 2" NOTE: NO DRYWALL @ CLG. REQUIRED IN THIS AREA - FIRE BLOCK @ PERIMETER OF OPNG. (80 SQ. FT. MAX.) 6"2" RADON VENT TO TERMINATE IN SUMP BASKET 6" 4" 10" GARAGE/HOUSE COMMON WALL 2x8 TREATED SILL OVERHANG FDN. 2'' GARAGE SLAB 2'' RIGID INSUL. MAIN FLR SEE FIRST FLOOR FOR GARAGE DOOR SIZE FOR M.O. NOTE: 4" LEDGE 6"2"CONC. CONC. 3 1/2'' CONC. FLOOR TYP. FND @ HOUSE 8" POURED CONC. (8'-4" H.) 20X8 FTG REBAR PER CODE TYP. FND @ BRG. WALL 2x4 STUDS 16" O.C. 16X8 FTG REBAR PER CODE 4" CONC. CURB KITCHEN ISLAND ABV. FLR. TRUSS CO. FUT. 2468OPT.18" FLR. TRUSSES19.2" O.C. SPACING2-2x10 (DR) (11'-2"x12'-7") (25'-5"x14'-7") RADON VENT FOUND. HELD IN 2" FOR INSULATION NOTE: (TYP.) NOTE: EXTERIOR HOUSE AND GARAGE/HOUSE COMMON FDN. WALLS TO BE HELD 2'' IN. DIMENSIONS SHOWN ARE TO FACE OF 2'' EXTERIOR RIGID INSULATION & FRAMING ABOVE TO BE 5000 PSI CONC. NOTE: ALL FOOTINGS 2'' MIN. 2x8 TREATED SILL-OVERHANGFDN. 1 1/2''8"2" TYP. SIDE WALL DETAIL FOUND. HELD IN 2" FOR INSULATION NOTE: (TYP.)2"2"2"2" FILL FOR SLAB UP 16 R (10" T., 7-3/4" MAX. R.) 40'-0"58'-0"6'-0"52'-0"66'-0"4'-0"29'-0"33'-0"15'-0"14'-0"10'-6 1/2"10'-0"12'-0"2'-0"19'-0"40'-0" 19'-0"21'-0" 20'-0" 19'-5 1/2" & HOUSE/PORCH 11'-0"10'-0"18" FLR. TRUSSES19.2" O.C. SPACING3-9 1/2" LSL (DR) FOUND. HELD IN 2" FOR INSULATION NOTE: (TYP.) F U T . 2 0 6 8 32x60FUT. TUB / SH SMOKECM / 12" CANT. ABV.2x6 BRG.2x6 BRG. 10' H. FOUND. WALL @ FRONT OF HOME NOTE: 10' H. FOUND. WALL@ FRONT OF HOME NOTE: w/ TOP HUNG TRUSSES w/ TOP HUNG TRUSSES 10' H. FOUND. WALL @ FRONT OF HOME NOTE: w/ TOP HUNG TRUSSES 10'-6"10'-6"19'-0" 11'-8 3/4"3'-2"4'-4 3/4"2'-8 1/2"8'-0"10'-0"3'-9"3'-10"6'-4"23'-6 1/2"9'-2 1/2"19'-3"9'-4 1/2"10'-1" 30"x30" CONC. PAD FTG. 6x6 COL. 2-2x10 (DR) 2-2x10 (FL) (2) TR 3-9 1/2" LSL (DR)3'-1"2'-10"2'-4"FUT. 24682'-10"2'-8"3'-8"4'-4"8'-0"9'-5 1/2"15'-11 1/2"9'-0" POURED FDN. APPROX. 1,678 NET SQ. FT. 20"x8" CONT. CONC. FTGS. REBAR PER CODE 42" H. x 8" W. POURED CONC. FOUNDATION WALL 2" RIGID INSULATION 1 TRTD. PLATE 6042 SLIDER @ 7' 8'-6"11'-10"6'-2"6'-9" 2-9 1/2" LSL 2-9 1/2" LSL 6'-9" 6042 SLIDER @ 7'8042 SLIDER @ 7' 3-9 1/2" LVL 26'-6"13'-6" * DUAL ZONE FURNACE UFER Ground -Provide 20' Rebar in footing and stub up near electrical service panel. BWPs Above SCALE: 3/16" = 1'-0" MAIN FLOOR PLAN 4 7 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 13, BLOCK 6, SUMMERS CREEK17989 GRESFORD LN., LAKEVILLE"CHARLESTON" 1640 PLANMARK ELLIOTT HOMES5-12-21 SELECT 6-7-21 LOT CHNG. 7-6-21 PERMIT 8-17-21 REV. #1 OF SHEETTBDWGAS RANGEMICRO ABV. FLUSH OH. LNDRY. DRYER WASHER 9' CLG. / LVP WIRE SH. (VENT TO OUTSIDE)NOTE: - STD. BASE & CASING TO BE PRINCETON - 1/2 WALL w/ WD. CAP & INVERTED CASING NOTE: 2X6 EXT. WALLS U.N.O. 2X4 INT. WALLS U.N.O. - 42" UPPER CABINETS DOOR ROUGH OPENINGS: 83" HEIGHT 82" OVER VINYL CERAMIC TILE & WOOD 82" OVER CARPET SRO = SHEET ROCKED OPNG BIFOLD DOORS: PREHUNG UNITS: 2" WIDER THAN DOOR (EXAMPLE: 2668 ) 1 3/8" WIDER THAN DOOR FINISH SIZE NOTED ON PLAN CO = CASED OPENING ( WOOD ) (EXAMPLE: 2668 ) FINISH SIZE NOTED ON PLAN RO. 1 1/2" WIDER, 83" HIGH R.O. 1" WIDER, 83" HIGH PER SPECS DRIVEWAY NOTE: REF. KITCHEN 9' CLG. / LVP 13'-2" x 12'-6" (155 SQ. FT.) 3-14" LVL GREAT ROOM 9' CLG. / LVP FLR.SLIMLINE SL512'-8" x 15'-0" (170 SQ. FT.) / LVP 42" W. CONC. SIDEWALK FIBRGLS. 60x36 SHWR. UNIT 5'-0"210682-9 1/2" LSL FOYER 9' CLG. / LVP6'-5" x 7'-1" (69 SQ. FT.) PORCH CONCRETE O. BATH 9' CLG. / VIN. 2x6 WALLS U.N.O. 4" SLOPED CONC. GARAGE CEIL. TO BE 5/8" TYPE 'X' GYP. BD. WALLS TO BE 1/2" GYP.SHEATHING. ALL WALLS & CEILINGS TO HAVE ONE COAT FIRETAPE GARAGE SLOPE CONC.6'x8' PATIO DR. 16'x7' O.H.D.R.O. 16'-1" FRAMING O. CLST 8' CLG. / CARPET36" VAN. BEDROOM #2 / OFFICE 3648 SH @ 8'9' CLG. / LVP FLR. w/ WD. CAP MANUF. TRUSSES24 O.C.(12'-3"x12'-0") EXTERIOR FLOOR PLAN DIMENSIONS ARE TO OUTSIDE OF SHEATHING, INTERIOR DIMENSIONS ARE TO FRAMING. NOTE: ALL DRS/ WIN.'S REQUIRE 4" ON SIDES FOR CASING NOTE: 2X6 EXT. WALLS U.N.O.2X4 INT. WALLS U.N.O. HEADER SPANS: UP TO 4'-11'' = 1 TRIMMER 5'-0'' AND BIGGER = 2 TRIMMERS UNLESS NOTED OTHERWISE INDICATES LOCATION OF SOLID BRG. (150 SQ. FT.) OWNERS BDRM. 9' CLG. / LVP FLR. (12'-6"x13'-7") (173 SQ. FT.) SMOKECM / SD 2 - 4072 SH @ 8' DN 16 R (10" T., 7-3/4" MAX. R.) 8/0 H. SOFFIT MANUF. TRUSSES 24 O.C. 12" LP COL.* BEADBD. CLG.ATTICACCESSAPPROX. 552 SQ. FT. MUDRM. 9' CLG. / LVP APPROX. 9'-0'' CLG. @ MAIN LEVEL APPROX. 1,678 SQ. FT.3068 MTL.3080 MTL.2468R&SH R&SH9' CLG. / CARPET9' CLG. 8' SOFFIT28682 6 6 8R&SHR&SH36" VAN. LIN.CAB. 3068FLDG. C'TOP.(OPEN UNDER) 2 - 4072 SH @ 8' DINING 9' CLG. / LVP FLR.11'-0" x 14'-10" (146 SQ. FT.) 3672 SH @ 8'3672 SH @ 8'4872 PICT. @ 8'MANUF. TRUSSES24 O.C.40'-0" 8'-6"11'-10"6'-2"6'-9"58'-0"6'-0"52'-0"12'-8"4'-10"5'-8"12'-8 3/4"7"4'-11"5'-2 1/2"5'-4 3/4"7'-8 1/4"5'-0 1/2"66'-0"4'-0"29'-0"33'-0"14'-4"3'-2"10'-6 1/2"10'-0"12'-0"2'-0"19'-0"40'-0" 19'-0"21'-0" 20'-0" 13'-0"6'-0" 6'-7"6'-5" 11'-0"10'-0" RADON VENT 4"7'-0"4"12'-4"2-7 1/4" LSL (DR)2-2x8 (DR)4"LP SOFFIT SD SMOKE CM / 2'-10 1/4"2'-4 1/2"2424 PICT. @ 8'2424 PICT. @ 8'2'-6 1/2"2'-6 1/2"PANEL SIDINGLINE OF LP2448 SH @ 8'5'-0"WD. STEP 3'-11 1/4"6'-0 3/4" 2'-0" 16'-10 1/2" 2'-7 1/2"2'-4"4'-0"5'-0"12" CANT.6'-4"8'-0"3'-9"3'-9"3'-0"3'-0"2-2x102-2x102-2x102-2x104 1/2"4 1/2"MANUF. TRUSSES24 O.C.FP CHASE FALSE 2-9 1/2" LSL (CONT.)2-9 1/2" LSL 2-2x10 (2) TR (2) TR 2-2x10 2-9 1/2" LSL P.H. TR 4x4 TRTD. COL.3068 PKT.3'-6"6'-0"4'-0"5'-0"13'-6" 6'-9" 26'-6" R&SH R&SH 1/2 WALL R&SHR&SH 2 6 6 89'-7 1/2"9'-6 1/2"26682 4 6 8 R&SH6'-0 3/4"4'-3"2'-10 1/2"6'-8 3/4"7"2'-5"4'-8 1/2"5'-10"12'-2 3/4"7"6'-2 1/4"5'-7 3/4"2'-5 1/2"5'-7"4'-9 1/4" 1'-0" 11"5'-2"5'-10"2'-1"2'-5 1/4" 3'-9" GIRDER TRUSS (3) 2x6(3) 2x6 MANUF. TRUSSES 24 O.C. 9 1/2"14'-8"P.H. TR BATH 30" VAN. PANTRY 9' CLG. / LVP (5) SH. 9' CLG. / VIN.2x65'-11 1/4"8'-4"32x60FGLS.TUB / SHPA 5'-0"5'-8"2'-10" 9 1/2"(5) SH.BUILT-IN CAB.BUILT-IN CAB.2 6 6 8 3 0 6 82424 PICT. @ 8'2-2x102424 PICT. @ 8'2-2x103'-0"9'-0"2'-4"36" GAS F.P.within 10' of bedroom door. -Min. 15" clearance to any obstruction from center of W.C., 24" in front(typ). 8 8 6 CS-PF CS-PF 5 7 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 13, BLOCK 6, SUMMERS CREEK17989 GRESFORD LN., LAKEVILLE"CHARLESTON" 1640 PLANMARK ELLIOTT HOMES5-12-21 SELECT 6-7-21 LOT CHNG. 7-6-21 PERMIT 8-17-21 REV. #1 OF SHEET SCALE: 1/4" = 1'-0" SECTION1 5 N.T.S. HOUSE / DECK CONNECTION DETAIL4 5 3/4" T & G FLOOR NOTE: SUBFLOOR JOINTS SHALL BESTAGGERED FROM FLOOR TRUSS ORJOIST JOINTS R=0.61 R=49.00 R=50.25 R=0.58 R=.061 TOTAL TRUSSES - 24" OC BLOWN INSULATION INTERIOR AIR FILM VAPOR BARRIER 15/32" OSB SHTG. 15# FELT EXTERIOR AIR FILM ICE AND SNOW SHIELD 30 YR. ARCH. ASPHALT SHINGLES 5/8" GYP BD ALUM. SOFFIT & FASCIA 1/2" GYP BD INTERIOR AIR FILM TOTAL SIDING PER SPECS 2x6 STUDS 16" OC R=1.06 R= R= R=21.00 R=0.45 R=0.17 R=23.36 VAPOR BARRIER FULL WALL BATT INSUL. EXTERIOR AIR FILM R=0.68 7/16" OSB SHTG. 8" AGGREGATE 6 MIL POLY. LAP SEAMS 12"10"HEEL HT.1/2" GYP. SHEATHING ON GARAGE WALLS5/8" TYPE 'X' GYP. BD. ON GARAGE CEILS. 18" FLOOR TRUSSES1'-6 3/4"9'-1 1/8"T.O. LOOKOUT T.O. SUBFLR. T.O. PLATE TRUSSES @ 24" O.C. (DESIGNED BY MFR) 6 12 R-49 INSUL.9'-4"GARAGE 4" SLOPED CONC. W/ REBAR PERENGINEERS REPORT 9'-0" POURED WALL DRAIN TILE 10" POURED WALL R-5 INSUL. ATINTERIOR FOUND.9'-1 1/8"O. BATH OWNERS BDRM. 20x8 CONC. FTG.16x8 CONC. FTG. 16x8 CONC. FTG. NOTE: TOP HUNG TRUSSES AT FRONT OF HOME (9'-0" H. FDN. WALL) SPRAY FOAM RIM SPRAY FOAM RIM 8'-2" +/-FOUND. HELD IN 2" FOR INSULATION TYP. NOTE: (INSUL. FLUSH w/ SHTG.) CANT. 2x8 SILL PLT. 1-1/2"3 1/2" CONC. FLOOR 2" RIGID INSULATIONR-10 w/ WATCHDOG WATERPROOF COATING AROUND HOUSE FOUND.8 1/4"6"HEEL HT.6 12 3 12 6 1/2"HEEL HT.FUT. BDRM. #5 R.I. BATH 8 1/4"4" 4'-0"7'-9"20X8 JOIST W/ 2-3/8" LAG BOLTS ICE & WATER EXTENDS 5" UP SHEATING UNDER INSTALL TOP OF LEDGER3 5/8" BELOW TOP OF 3/4" SUBFLOOR (THIS ALLOWS 5/4 X 4 THRESHOLD AT DOOR) HANGER TREATED 2X10 LEDGER RUN HOUSE WRAP BEHIND LEDGER (LEAVE 6" TAIL @ TOP, BOTTOM, & SIDES) HOUSEWRAP @ 24" O.C. -OR- EMBED 2" MIN.8 INCHES O.C. MAX OR EQUAL, W/ "LEDERLOK" FASTENERS CONT. 2X4 RIBBON SPRAY FOAM INSUL. R-21 MIN. RIM BOARD TREATED JOIST JOISTRIM BD. SKIRT 1" HOUSE END OF DECK HOUSE LATERAL LOAD SIMPSON DTT1Z DECK-TO CONNECTOR - (4) PER DECK OR 8-10DX1 1/2" NAILS 6-SD#9X1 1/2" SCREWS HDG WASHER OR SDWH 3/8" HDG LAG SCREW WITH TIMBER-HEX HDG SCREW (SHOWN) INTO TOP PLATE, STUDS, OR HEADER CONT. 2X8 RIBBON DRAIN TILE 3/4" WASHED ROCK CONTINUOUS UNDER SLAB0'-16" SILT FABRIC FOUNDATION WALL CONC. FTG. 4" DRAIN TILE 2 SCALE: NO SCALE5 TOP OF FDN.RIM DETAIL3 SCALE: NO SCALE5 2" RIGID INSULATION R-10 w/ WATCHDOG WATERPROOF COATING AROUND HOUSE FOUND. 2" RIGID INSULATION R-10 w/ WATCHDOG WATERPROOF COATING AROUND HOUSE FOUND. 2x8 TRTD. SILL SHEATHING FLUSH WITH INSULATION NOTE: FOUNDATION TO BE HELD IN 2" FROM SHEATHING & OUTSIDEDIMENSIONS. CANTED 1-1/2" 6 7 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 13, BLOCK 6, SUMMERS CREEK17989 GRESFORD LN., LAKEVILLE"CHARLESTON" 1640 PLANMARK ELLIOTT HOMES5-12-21 SELECT 6-7-21 LOT CHNG. 7-6-21 PERMIT 8-17-21 REV. #1 OF SHEET SCALE: 1/4" = 1'-0" SECTION1 6 N.T.S. PORTAL FRAME DETAIL2 6 N.T.S. RADON DETAIL3 6 SIMPSON STRONG TIE Ab46z 4" LEDGE HEADER HURRICANE CLIP ATTACHEDTO COLUMN& BEAM 11 7/8" OSB STRINGER W/ 2X4 BRACING 10 1/2" BULLNOSE LSL TREAD1X8 PINE S4S RISER NOTE: MAX RISE= 7 3/4" MIN. RUN= 10" 6'-8" CLEAR HEADROOM PWDR.BEDROOM #2 / OFFICEGREAT RM. 3/4" T & G FLOOR NOTE: SUBFLOOR JOINTS SHALL BESTAGGERED FROM FLOOR TRUSS ORJOIST JOINTS ALUM. SOFFIT & FASCIA 8" AGGREGATE 6 MIL POLY. LAP SEAMS 12" 18" FLOOR TRUSSES1'-6 3/4"9'-1 1/8"T.O. SUBFLR. T.O. PLATE TRUSSES @ 24" O.C. (DESIGNED BY MFR) R-49 INSUL.9'-4"W/ REBAR PER ENGINEERS REPORT 9'-0" POURED WALL DRAIN TILE 10" POURED WALL R-5 INSUL. ATINTERIOR FOUND. 20x8 CONC. FTG.16x8 CONC. FTG. NOTE: TOP HUNG TRUSSES AT FRONT OF HOME (9'-0" H. FDN. WALL) SPRAY FOAM RIM SPRAY FOAM RIM 8'-2" +/-FOUND. HELD IN 2" FOR INSULATION TYP. NOTE: (INSUL. FLUSH w/ SHTG.) CANT. 2x8 SILL PLT. 1-1/2" 3 1/2" CONC. FLOOR CONC. STOOP 2" RIGID INSULATIONR-10 w/ WATCHDOG WATERPROOF COATING AROUND HOUSE FOUND. PORCH 12" SQ. LP COLUMN10"HEEL HT.6 12 T.O. LOOKOUT MECH. / STORAGEFUT. FAMILY ROOM 6 12 KITCHEN 8 1/4"4x4 TRTD. COL. 2x OVER 10" TRIM 2 5 3 5 20X8 SIMPSON STHD14 HOLD DOWN SIMPSON LSTA36 STRAP ON INSIDE FACE OF WALL 5/8" ANCHOR BOLT 1/2" OSB SHEATHING HEADER- SEE PLAN FOR SIZE FASTEN SHEATHING TO HEADER WITH 8d COMMON OR GALVANIZED BOX NAILS IN 3" GRID PATTERN ASSHOWN, AND 3" O.C. IN ALL FRAMING MEMBERS TYP. SHEATHING SPLICE (IF NEEDED) MUST BE LOCATED WITH-IN 24" OF THE MID HEIGHTOF THE DOOR OPENING. PROVIDE 2-2X6BLOCKING BEHIND SPLICE FASTEN TOP PLATE TO HEADER WITH2 ROWS OF 16d SINKER NAILS 3" O.C. BLOCK BACK SIDE OF HEADER FLUSH WITH STUDSAT STRAP LOCATIONS UNEXCAVATED SOIL ALL SLABS WILL HAVE A MIN. 4" CLEAN AGGREGATE, COVERED BY 6 MIL POLY. THIS POLY WILL HAVE 12" LAP AT ALL SEAMS. ALL TEARS OR PUNCTURES WILL BE SEALED OR COVERED BY POLY. ALL OPENINGS WILL BE SEALED USING POLYURETHANE CAULK OR ELASTOMERIC SEALANT AT ALL OPNGS. AN INSTALLED 3" GASTIGHT PVC PIPE WILL BE CONNECTED TO THE DRAIN TILE SYSTEM. A "T" FITTING WILL BE INSTALLED WITH 10 L.F. EACH END OF THE "T", OF PERFORATED PIPE, INTO THE DRAIN TILE SYSTEM. THE SHORTEST ROUTE WILL BE USED TO EXIT THE ROOF SYSTEM, WITH A MAX. OF 2 90 DEGREE ELBOWS. IN UNCONDITIONED AREAS, THE RADON EXHAUST PIPE WILL BE INSULATED WITH AN R4 SLEEVE. THIS PIPE WILL BE LABELED "PASSIVE RADON" AT ALL ACCESSIBLE LOCATIONS. AT ROOF EXIT LOCATIONS, MAINTAIN A 10' DISTANCE TO ANY WINDOW LOCATION, 2' BELOW EXHAUST POINT AND ANY ADJACENT STRUCTURE. THE LOCATION OF THE EXIT POINT, IN TRUSS AREA, WILL BE CLEAR OF ANY OBSTRUCTIONS WITHIN 24" HORIZONTALLY AND 36" VERTICALLY. INSTALL AN OUTLET AND PULL CHORD LIGHT FOR FUTURE EXHAUST FAN ADDITION. SCALE: 1/4" = 1'-0" MAIN FLR. ELECTRICAL PLAN 7 7 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 13, BLOCK 6, SUMMERS CREEK17989 GRESFORD LN., LAKEVILLE"CHARLESTON" 1640 PLANMARK ELLIOTT HOMES5-12-21 SELECT 6-7-21 LOT CHNG. 7-6-21 PERMIT 8-17-21 REV. #1 OF SHEET SCALE: 1/4" = 1'-0" LOWER LEVEL ELECTRICAL PLAN SS FANRGH.-IN SDISP TVIN CAB.TV W.P.S3S3LTS.PENDANT 3 SS C/L 7'-6"3'-2"6'-3 1/2"SD SD GDO G.F.I.P.SG.F.I.P.G.F.I.P.G.F.I.P.W.P.SS S3 SSS TO LIGHT SG.F.I.P.DW GAS RANGEMICRO ABV.LNDRY. DRYER WASHER (VENT TO OUTSIDE)REF. KITCHEN GREAT ROOM FOYER PORCH O. BATH GARAGE O. CLST BEDROOM #2 / OFFICE OWNERS BDRM. SMOKECM / ATTICACCESSMUDRM. DINING SMOKE CM / SSS4S3S4SG.F.I.P. S3 S3 S3S S SPANTRY G.F.I.P.SS BATH SS (CAP OPNG.) FANRGH.-IN (CAP OPNG.) S DUPLEX CONVENIENCE OUTLET DUPLEX OUTLET ABOVE COUNTER WEATHERPROOF DUPLEX OUTLET HALF-SWITCHED DUPLEX OUTLET DUPLEX OUTLET IN FLOOR 220 VOLT OUTLET WALL SWITCH THREE-WAY SWITCH FOUR-WAY SWITCH CEILING MOUNTED INCANDESCENT LIGHT FIXTURE WALL MOUNTED INCANDESCENT LIGHT FIXTURE RECESSED INCANDESCENT LIGHT FIXTURE LIGHT FIXTURE WITH PULL CHAIN TRACK LIGHT FLOURESCENT LIGHT FIXTURE EXHAUST FAN EXHAUST FAN/LIGHT COMBINATION CHIMES (OPTIONAL) SMOKE DETECTOR TELEPHONE (OPTIONAL) TELEVISION (OPTIONAL) THERMOSTAT ELECTRIC METER ELECTRIC PANEL SPEAKER (OPTIONAL) TV T M CH SD P.C. S S S 4 3 W.P. ELECTRICAL KEY DUPLEX OUTLET (GROUND FAULT PROTECTED)G.F.I.P. RECESSED INCANDESCENT EYE BALL FIXTURE CARBON MONOXIDE DETECTORCM GARAGE DOOR OPENER OUTLETGDO FLUORESCENT LIGHT PER SPEC FAN/LIGHT COMBO PREWIRE, PROVIDE ADEQUATE SUPPORT 4 BULB FIXTURE 3 BULB FIXTURE 200 AMP SERVICE LIGHTING PACKAGE: T.B.D. LINE TO DRYER: T.B.D.G.F.I.P.EXCH.AIR FURN F.D. WH SMOKECM / S S3S TO LIGHT A/C UNIT w/ BRACKET G.F.I.P.G.F.I.P.MECH. / STORAGE WS FUT. BDRM. #5 FUT. FAMILY ROOM R.I. BATH SUMP H20 OPT. * WIRING FOR DUAL ZONE FURNACE BW 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 13, BLOCK 6, SUMMERS CREEK17989 GRESFORD LN., LAKEVILLE"CHARLESTON" 1640 PLANMARK ELLIOTT HOMES5-12-21 SELECT 6-7-21 LOT CHNG. 7-6-21 PERMIT 8-17-21 REV. #1 SHEET N.T.S. MAIN LEVEL BRACEWALL1 BW N.T.S. BRACEWALL DETAILS3 BW N.T.S. LOWER LEVEL BRACEWALL2 BW GARAGE PORTAL FRAMING PER BUILDING CODE IRC R602.10.6.4 BRACED WALL METHOD CS-WSP BRACED WALLLINE 2BRACED WALLLINE A 3'-5" PANEL BRACED WALLLINE C 3'-5" PANEL 3'-2" PANEL3'-5" PANEL 4'-0" PANEL8'-0" PANEL4'-0" PANEL4'-0" PANEL4'-0" PANEL4'-0" PANEL8'-0" GYP. PANEL 3'-3" PANEL4'-2" PANEL 1'-4" PANEL LNDRY.KITCHEN GREAT ROOM FOYER PORCH O. BATH GARAGE O. CLST BEDROOM #2 / OFFICE OWNERS BDRM.ATTICACCESSMUDRM. DINING PANTRYBATHBRACED WALLLINE 16'-0" GYP. PANEL BRACED WALLLINE B 8'-0" GYP. PANEL 4'-0" PANEL4'-0" PANEL4'-0" PANELMIN. 3''x11 1/4'' NET HEADER(STEEL HDR. PROHIBITED) EXTENT OF HEADER W/ SINGLE PORTAL FRAME ONE BRACED WALL PANEL 10'-0'' MAX. HEIGHT(TOP OF HDR.)TOP OF FDN. TOP OF CONC FLOOR AT OPENING MIN. 2-2x4 FRAMING STUD POST CONTINUOUS HEADER WITH DOUBLE PORTAL FRAMES TWO BRACED WALL PANELS 6' TO 18' OPENING FASTEN TOP PLATE TO HEADER W/ 2 ROWS OF 16d SINKER NAILS @ 3'' O.C. TYP. 1000 LB. STRAP OPPOSITE SIDE OF SHEATHING FASTEN SHEATHING TO HEADER W/ 8d COMMON OR GALV. BOX NAILS IN 3'' GRIDPATTERN SHOWN AND 3'' O.C. IN ALLFRAMING(STUDS, BLOCK'G AND SILLS)TYP. MIN. WIDTH PER TABLE R602.10.5 3/8'' MIN. WOOD STRUCTURAL PANEL SHEATH'G. MIN. 2-2x4 MIN. 4200 LB. TIE DOWN DEVICE(EMBED INTOFOUNDATION AND NAILED INTO FRAMING MIN. (2) 1/2'' DIA. ANCHOR BOLT INSTALLED PER R403.1.6 W SEE LEFT FORTYP. PORTALFRAME CONST. FOR A PANEL SPLICE(IF NEEDED) PANELEDGES SHALL BE BLOCKED AND OCCURWITHIN 24'' OF MID-HEIGHT. ONE ROW OF TYP. SHEATH'G. TOFRAMING NAILING IS REQUIRED. IF 2x4 BLOCK'G. IS USEDTHE 2x4'S MUST BE NAILED TOGETHER W/ 3 16dSINKER NAILS W/ 2''x2''x3/16'' PLATE WASHER12'-0'' MAX. HEIGHT(TOP OF WALL)FULL HEIGHT OF WALL - SEE TO RIGHT FOR SPLICESPONY WALL HT.EXTENT OF HEADER TENSION STRAP PERTABLE R602.10.6.4 (ONOPPOSITE SIDE OF SHEATHING ANCHOR BOLTSPER SECTIONR403.1.6 BRACED WALL LINECONTINUOUSLYSHEATHED WITH WOOD STRUCTURALPANELS TOP OF FLOOR AT OPENING FLOOR FRAMING ASSEMBLY PER PLAN W/ WOOD STRUCTURAL PANEL SHEATHING TOP OF FLOOR AT OPENING FLOOR FRAMING ASSEMBLY PER PLAN WOOD STRUCTURAL PANEL SHEATHING TO TOP OF BAND OR RIM JOIST NAIL SOLE PLATE TO FLR FRAMING PERTABLE R602.3(1) (2) FRAMING ANCHORS APPLIED ACROSSSHEATHING JOINT WITH A CAPACITY OF 670# IN HORIZ. AND VERT. DIRECTIONS SEE LEFT FOR TYP. PORTALFRAME CONST. ON CONCRETE FOUNDATION ON RAISED WOOD FLOOR - FRAMING ANCHOR OPTION TOP OF FLOOR AT OPENING FLOOR FRAMING ASSEMBLY PER PLAN W/ WOOD STRUCTURAL PANEL SHEATHING TOP OF FLOOR AT OPENING FLOOR FRAMING ASSEMBLY PER PLAN WOOD STRUCTURAL PANEL SHEATHINGTO TOP OF BAND OR RIM JOIST NAIL SOLE PLATE TO FLR FRAMING PERTABLE R602.3(1) SEE LEFT FORTYP. PORTALFRAME CONST. ON RAISED WOOD FLOOR - OVERLAP FLOOR OPTION MIN. OVERLAP 9 1/4''WOOD STRUCTURAL PANEL SHEATHING CONTINUOUS OVER BAND OR RIM JOIST MIN. OVERLAP 9 1/4''ATTACH TO RIM/BAND JOIST W/ 8d COMMON NAILS AT 3'' O.C. AS SHOWN DBL TOP PLATE BOTTOM PLATE STUDS AT 16'' O.C. W/ 6d NAILS @ 6'' O.C. 4'-0"8'-0'' MIN., SEE PLANINTERMEDIATE 6''3"W/ 6d NAILS @ 3'' O.C. EDGES NAILED 3'-8" PANEL FUT. BDRM. #5 FUT. FAMILY ROOM 4'-0" PANEL 8'-0" PANEL4'-0" PANEL 4'-0" PANEL4'-0" PANEL Builders Associaton of Minnesota version 101014 New Construction Energy Code Compliance Certificate Place your logo here Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. Date Certificate Posted Mailing Address of the Dwelling or Dwelling Unit City 17989 Gresford Ln Lakeville Name of Residential Contractor MN License Number Mark Elliot Homes BC665904THERMAL ENVELOPE RADON CONTROL SYSTEM Insulation Location Total R-Value of all Types ofInsulationType: Check All That Apply X Passive (No Fan)Non or Not ApplicableFiberglass, BlownFiberglass, BattsFoam, Closed CellFoam Open CellMineral FiberboardRigid, Extruded PolystyreneRigid, IsocynurateActive (With fan and monometer orother system monitoring device) Location (or future location) of Fan: Attic Other Please Describe Here Below Entire Slab Foundation Wall R-15 Interior Walls Perimeter of Slab on Grade Rim Joist (1st Floor)R-20 X Interior Rim Joist (2nd Floor+) Wall R-21 X Ceiling, flat R-49 X Attic Ceiling, vaulted N/A Bay Windows or cantilevered areas R-30 X Floors over unconditioned area N/A Describe other insulated areas Building envelope air tightness:Duct system air tightness: Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces Average U-Factor (excludes skylights and one door) U: 0.29 X Not applicable, all ducts located in conditioned space Solar Heat Gain Coefficient (SHGC):0.28 R-value MECHANICAL SYSTEMS Make-up Air Select a Type Appliances Heating System Domestic WaterHeater Cooling System X Not required per mech. code Fuel Type NAT Gas NAT Gas Electric Passive Manufacturer Bryant Rheem Bryant Powered Model 91250036060 PROG50 113ANA024 Interlocked with exhaust device.Describe: Rating or Size Input in BTUS: 60,000 Capacity in Gallons: 50 Output in Tons: 1.5 Other, describe: Efficiency AFUE or HSPF% 92 0.7 SEER /EER 13 SEER/R4 10 Location of duct or system: Residential Load Calculation Heating Loss Heating Gain Cooling Load 55,995 18,534 18,534 Cfm's X " round duct OR MECHANICAL VENTILATION SYSTEM " metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Combustion Air Select a Type X Not required per mech. code Select Type Passive Heat Recover Ventilator (HRV) Capacity in cfms:Low: High:Other, describe: X Energy Recover Ventilator (ERV) Capacity in cfms:Low: 50 High:140 Location of duct or system: Balanced Ventilation capacity in cfms:Mechanical Room Location of fan(s), describe: Cfm's Capacity continuous ventilation rate in cfms:6" " Flex duct OR Total ventilation (intermittent + continuous) rate in cfms: " metal duct NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. A National Pollutant Discharge Elimination System (NPDES) Construction Stormwater Permit is required for “Construction activity that results in land disturbance of equal to or greater than one (1) acre or if a project is part of a common plan of development that will ultimately disturb greater than one (1) acre,” (NPDES Permit, Section 1.2). Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ *Primary Company Contact: _________________________________________________________________ *Should a site be deemed noncompliant, this individual will be notified Phone #: ____________________________ Email: ______________________________________________ If you are not covered under a NPDES Construction Stormwater Permit administered by the Minnesota Pollution Control Agency (MPCA), an erosion and sediment control plan MUST be approved as part of the residential building permit application. “Permittees must ensure a trained person will inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than ½ inch in 24 hours,” (NPDES Permit, Section 11.2). The City of Lakeville reserves the right to request weekly inspection logs. The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name: ____________________________________ Company: ___________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: __________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed I understand the above information to be accurate and I have read, understood, and accepted all terms and conditions of the NPDES Permit (MN R 100001). Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 Nick Reimler 08/09/21 X KP