Loading...
HomeMy WebLinkAboutLA194073 - 17995 Gresford Ln Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov Nick Reimler CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ 7 Metro Heating and Air 612-590-2678 612-590-2678 609 150th Ave NE Ham Lake Mn 55304 MB004178 12/3/22 RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: 20195 Holyoke Avenue, Lakeville, MN 55044 952-985-4400  952-985-4499 fax www.lakevillemn.gov Sewer & Water Tie Card Address:________________________________________ Contractor:______________________________________ Permit Number:__________________________________ Final Date:________________ Street Drain-Tile:______ Size of Water Service: 1” Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME OF SEWER & WATER INSPECTION 1 7SCALE: 1/4" = 1'-0" FRONT ELEVATION GENERAL NOTES: 1. ALL DOOR AND WINDOW HEADERS TO BE S.P.F. #2 OR BETTER, SEE PLANS FOR SIZES. 2. HOUSE TO BE BUILT PER CURRENT I.R.C. CODES. 3. VERIFY GRADES AND ADJUST FOUNDATION/FOOTING STEPS AS NEEDED. 4. SEE PLANS FOR CEILING HEIGHTS 5. 4' HIGH POURED FDN. WALLS STD. 6. FLOOR PLAN DIMENSIONS ARE TO FACE OF FRAMING AND FOUNDATION. 7. ALL TRADES & SUPPLIERS TO REVIEW & VERIFY INFORMATION PERTINENT TO THEIR WORK AND NOTIFY CONST. OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 8. NOTED CABINET SIZES ARE +/- AND TO BE FIELD VERIFIED. 9. TRADES TO VERIFY BASE AND TRIM SIZE PRIOR TO CONSTRUCTION. 10. ALL WALLS MORE THAN 10' H. TO BE S.P.F. #2 OR BETTER. 11. EXTERIOR ELEVATIONS ARE CONCEPTUAL ONLY: HOME SITE, FILL AND TOPOGRAPHY WILL DICTATE ACTUAL GRADES AND MAY VARY FROM THOSE SHOWN ON THE PLAN. 12. NOTE: SUBFLOOR JOINTS SHALL BE STAGGERED FROM FLOOR TRUSS OR JOIST JOINTS OF SHEET 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X17995 GREFORD LN., LAKEVILLELOT 14, BLOCK 6, SUMMER'S CREEKHAMPTON 1760 PLANMARK ELLIOTT HOMES4-26-2021 SELECT 6-24-2021 PERMIT SCALE: 1/8" = 1'-0" ROOF PLAN SEE ROOF PLAN FOR ROOF PITCHES AND OVERHANGS 25'-9"CONC. PORCH 6:12 ALUM. SOFFIT & FASCIA 30 YR. ARCH. ASPHALT SHINGLES 2x OVER 8" TRIM 8" LP TRIM4'-6" LP SMARTSIDE LAP SIDING (4")9'-1 1/8"T.O. SUBFLR. T.O. PLATE 1'-8 1/4"T.O. FDN.6" TRIM 6" TRIM 9'-9 1/8"@ GARAGE T.O. PLATE 12 12 12 12 1'-6"6'-11 1/2"T.O. 3048 SH STAT. (BLACKENED) STONE WHERE INDICATED 12" CANT. 10" TRIM C/L T.O. FDN.7'-8"@ DORMER T.O. PLATE 10'-6"FP CHASE 24"x60" FALSE LP PANEL6:12 6:12 6" TRIM 8" LP TRIM12" TRIM 6" TRIM 6"LP PANEL 12 12 12 12 12 12 5'-0"STONE CAP STONE TOTAL: 93.07 SQ. FT. (41.15%) TOTAL SQ. FT.: 226.15 MATERIAL CALCULATIONS: FRONT ELEV. LP TRIM / PANEL: 133.08 SQ. FT. (58.85%) STONE TOTAL: 139.91 SQ. FT. (6.24%) TOTAL SQ. FT.: 2242.58 MATERIAL CALCULATIONS: ALL ELEV. LP LAP SIDING TOTAL: 1422.53 SQ. FT. (63.43%) LP TRIM / PANEL: 680.14 SQ. FT. (30.33%)8" LP TRIM8" LP TRIM8" TRIM 12" TRIM LP PANELLP PANELSADDLENOTE: SEE ROOF TRUSS LAYOUT FOR TRUSS DIRECTION AND GIRDER LOCATIONS PROVIDED BY MANUFACTURER PROVIDE ATTIC VENTILATION EQUAL TO 1/150th ATTIC AREA. IF 50% OR MORE IS PROVIDED IN UPPER PORTION OF THE ROOF AND REMAINDER IS PROVIDED IN SOFFIT VENTS, IT MAY BE REDUCED TO 1/300th ATTIC AREA. ICE AND WATER SHIELD 6'-0" IN FROM EAVES 1'-6" ON EACH SIDE OF VALLEY WHERE WALLS MEET ROOF ICE & WATER SHIELD SHOULD RUN UP WALL 1'-6" AND OUT FROM WALL 1'-6" NOTE: NOTE: NOTE: 1'-6"2'-0"RIDGERIDGE 1'-0"6:126:126:1212:12 2'-0"2'-0"4'-0"6:1212:1212:12 6:1212:12 1'-6" 1'-6"1'-6"2'-0"2'-0"6'-0"12:126:1212:1212:12 Concept Approval ONLYSubject to Field Inspection Inspector Date 2015 MN Bldg Code 08/19/2021shutchins EXTERIOR ELEVATIONS ARE CONCEPTUAL ONLY: HOME SITE, FILL AND TOPOGRAPHY WILL DICTATE ACTUAL GRADES AND MAY VARY FROM THOSE SHOWN ON THE PLAN.2 7 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X17995 GREFORD LN., LAKEVILLELOT 14, BLOCK 6, SUMMER'S CREEKHAMPTON 1760 PLANMARK ELLIOTT HOMES4-26-2021 SELECT 6-24-2021 PERMIT OF SHEET SIDE ELEVATION SIDE ELEVATION SCALE: 3/16" = 1'-0" REAR ELEVATION SCALE: 3/16" = 1'-0" SCALE: 3/16" = 1'-0" @ GARAGE 9'-1 1/8"T.O. FDN. ALUM. SOFFIT & FASCIA A/C UNIT T.O. PLATE 9'-1 1/8"T.O. SUBFLR. T.O. FDN.1'-8 1/4"10" TRIM LP CORNERS 4" LP TRIM @ WDWS. & DOORS TYP. 12 6 12 6 LP SIDING PER SPECS T.O. PLATE SEE ROOF PLAN FOR PITCHES AND OVERHANGS 8" TRIM 7'-8"@ DORMER T.O. PLATE 12:12 12:12 12 6 LP PANEL 2'-0" VERIFY GRADE 12 6 12:12 LP PANELALUM. SOFFIT & FASCIA LP PANEL 12 6 T.O. PLATE 9'-1 1/8"T.O. SUBFLR. T.O. FDN.1'-8 1/4"12 6 10" TRIM 12" CANT.LP CORNERS 4" LP TRIM @ WDWS. & DOORS TYP. LP SIDING PER SPECS FP VENT SADDLE SEE ROOF PLAN FOR PITCHES AND OVERHANGS 12:12 12:12 12 6 LP PANELLP PANEL12 6 VERIFY GRADE WFPWFP T.O. PLATE 9'-1 1/8"T.O. SUBFLR. T.O. FDN.1'-8 1/4"LP CORNERS 4" LP TRIM @ WDWS. & DOORS TYP. 10" TRIM 12" CANT. WFPWFPWFPWFP SEE ROOF PLAN FOR PITCHES AND OVERHANGS ALUM. SOFFIT & FASCIA 6:12 LP SIDING PER SPECS 12 12 12 12 LP PANEL12 12 TRTD. DECK LEDGER (APPROX. 24') 10" TRIM SCALE: 3/16" = 1'-0" FOUNDATION PLAN 3 7 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X17995 GREFORD LN., LAKEVILLELOT 14, BLOCK 6, SUMMER'S CREEKHAMPTON 1760 PLANMARK ELLIOTT HOMES4-26-2021 SELECT 6-24-2021 PERMIT OF SHEET A/C UNIT w/ BRACKET FURN F.D. WH MECH. / STORAGE WS 3068CONC. H.B. H.B. 2" LEDGE TYP. TO PROVIDE ADD'L.SUPPORT FOR FILL FOR SLAB TYP. FND @ HOUSE / GARAGE 10" POURED CONC. W/ 4" LEDGE INSIDE 20X8 CONC. FTG. 2" FOAM SUMP H20 4" LEDGE 2" FOAM TYP. FND @ STOOP 10" POURED CONC. W/ 4" LEDGE INSIDE 20x8 CONC. FTG. UNEXCAVATED 2" NOTE: NO DRYWALL @ CLG. REQUIRED IN THIS AREA - FIRE BLOCK @ PERIMETER OF OPNG. (80 SQ. FT. MAX.) 6"2" RADON VENT TO TERMINATE IN SUMP BASKET 6" 4" 10" GARAGE/HOUSE COMMON WALL 2x8 TREATED SILL OVERHANG FDN. 2'' GARAGE SLAB 2'' RIGID INSUL. MAIN FLR SEE FIRST FLOOR FOR GARAGE DOOR SIZE FOR M.O. NOTE: 4" LEDGE 6"2"3 1/2'' CONC. FLOOR TYP. FND @ HOUSE 8" POURED CONC. (8'-4" H.) 20X8 FTG REBAR PER CODE KITCHEN ISLAND ABV. FLR. TRUSS CO. OPT.18" FLR. TRUSSES19.2" O.C. SPACING2-2x10 (DR) RADON VENT FOUND. HELD IN 2" FOR INSULATION NOTE: (TYP.) NOTE: EXTERIOR HOUSE AND GARAGE/HOUSE COMMON FDN. WALLS TO BE HELD 2'' IN. DIMENSIONS SHOWN ARE TO FACE OF 2'' EXTERIOR RIGID INSULATION & FRAMING ABOVE TO BE 5000 PSI CONC.NOTE: ALL FOOTINGS 2'' MIN. 2x8 TREATED SILL-OVERHANGFDN. 1 1/2''8" 2" TYP. SIDE WALL DETAIL FOUND. HELD IN 2" FOR INSULATION NOTE: (TYP.) 2" 2" UP 17 R (10" T., 7-3/4" MAX. R.) 40'-0"60'-0"69'-0"11'-0"31'-0"27'-0"8'-11"3'-5"9'-0 1/2"11'-6"5'-0"5'-6"16'-6"10'-6"7'-0" & HOUSE/PORCH 18" FLR. TRUSSES19.2" O.C. SPACING3-9 1/2" LSL (DR) FOUND. HELD IN 2" FOR INSULATION NOTE: (TYP.)12" CANT. ABV.2x6 BRG.2x6 BRG.18" FLR. TRUSSES19.2" O.C. SPACING9'-4" H. FOUND. WALL @ FRONT OF HOME NOTE: 9'-4" H. FOUND. WALL @ FRONT OF HOME NOTE: w/ TOP HUNG TRUSSES w/ TOP HUNG TRUSSES 9'-4" H. FOUND. WALL @ FRONT OF HOME NOTE: w/ TOP HUNG TRUSSES 11'-1 1/2"15'-10 1/4" 11'-8 3/4"3'-2"1'-3"3'-0"7'-10"13'-0 1/4"3'-9"3'-10"7'-1 1/2"21'-3"17'-0"21'-9"9'-1 1/2"10'-4" 30"x30" CONC. PAD FTG. 6x6 COL. 2-2x10 (DR) 2-2x10 (FL) (2) TR 3-9 1/2" LSL (DR)5'-5" 2668L.L. BATH 5/0 BI-PASS 20682"BEDRM. #5 FAMILY ROOM CARPET CARPET (11'-8"x11'-11") (24'-11"x12'-4") 24682"6'-0"2"14'-0"26'-0" 3'-2 1/2"2'-0"7'-9 3/4" 36" VAN. TYP. FND @ BRG. WALL 2x4 STUDS 16" O.C. 16X8 FTG REBAR PER CODE 4" CONC. CURB (936 FIN., 826 UNFIN.) APPROX. 1,762 NET SQ. FT. 32x60TUB / SH2-2x10 (FL) 20"x8" CONT. CONC. FTGS. REBAR PER CODE 42" H. x 8" W. POURED CONC. FOUNDATION WALL 2" RIGID INSULATION 1 TRTD. PLATE 6042 SLIDER @ 7' 2-9 1/2" LSL 8042 SLIDER @ 7' 3-9 1/2" LVL FBGLS.VINYL FLR. H. SRO R&SH 9'-0" POURED FDN. 2/6 x 7/0 LIN. (5) SH.TRP.H.TB 7'-0"7'-0"13'-3"3'-0"FILL FOR SLAB 69'-0"40'-0" 6'-0" 20'-0" 10'-6"10'-6" 13'-0"21'-0" 20'-0" FLEX CARPET (11'-9"x7'-7") 2x6 6042 SLIDER @ 7' 2-9 1/2" LSL 5'-8"11'-6"8'-10" SD SMOKECM / EXCH.AIR 4" LEDGE2" FOAM NOTE: ADD (2) SUPPLY* HVAC AUTO ZONING AIRS TO STORAGEAREA (VERIFY LOCATION) NOTE: ADD INSULATION TO ALL EXT. WALLS @ MECH. / STORAGE TYP. SCALE: 3/16" = 1'-0" MAIN FLOOR PLAN 4 7 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X17995 GREFORD LN., LAKEVILLELOT 14, BLOCK 6, SUMMER'S CREEKHAMPTON 1760 PLANMARK ELLIOTT HOMES4-26-2021 SELECT 6-24-2021 PERMIT OF SHEETP.H.TBTRDW GAS RANGEMICRO ABV. FLUSH OH. LNDRY. DRYERWASHER 9' CLG. / LVP WIRE SH. (VENT TO OUTSIDE) NOTE: - STD. BASE & CASING TO BE PRINCETON - 1/2 WALL w/ WD. CAP & INVERTED CASING NOTE: 2X6 EXT. WALLS U.N.O. 2X4 INT. WALLS U.N.O. - 42" UPPER CABINETS DOOR ROUGH OPENINGS: 83" HEIGHT 82" OVER VINYL CERAMIC TILE & WOOD 82" OVER CARPET SRO = SHEET ROCKED OPNG BIFOLD DOORS: PREHUNG UNITS: 2" WIDER THAN DOOR (EXAMPLE: 2668 ) 1 3/8" WIDER THAN DOOR FINISH SIZE NOTED ON PLAN CO = CASED OPENING ( WOOD ) (EXAMPLE: 2668 ) FINISH SIZE NOTED ON PLAN RO. 1 1/2" WIDER, 83" HIGH R.O. 1" WIDER, 83" HIGH PER SPECS DRIVEWAY NOTE: REF. KITCHEN 9' CLG. / LVP12'-3" x 12'-6" (155 SQ. FT.) 3-14" LVL GREAT ROOM 9' CLG. / LVP FLR.36" GAS F.P.12'-8" x 13'-0" (167 SQ. FT.) C.T. BASE 60x36 SHWR. & WALLS 5'-0" 2-9 1/2" LSL FOYER 9' CLG. / LVP5'-11" x 10'-7" (63 SQ. FT.) PORCH CONCRETE O. BATH 9' CLG. / LVP 2x6 WALLS U.N.O. 4" SLOPED CONC. GARAGE CEIL. TO BE 5/8" TYPE 'X'GYP. BD. WALLS TO BE 1/2" GYP.SHEATHING. ALL WALLS & CEILINGS TO HAVE ONE COAT FIRETAPE GARAGE SLOPE CONC.6'x8' PATIO DR. 16'x7' O.H.D. R.O. 16'-1" FRAMING O. CLST 9' CLG. / LVP FLR.36" VAN. BATH 2 FLEX ROOM 3648 SH @ 8'9' CLG. / CARPET 9' CLG. / LVP 1/2 WALL w/ WD. CAP MANUF. TRUSSES24 O.C.(12'-0"x13'-2") EXTERIOR FLOOR PLAN DIMENSIONS ARE TO OUTSIDE OF SHEATHING, INTERIOR DIMENSIONS ARE TO FRAMING. NOTE: ALL DRS/ WIN.'S REQUIRE 4" ON SIDES FOR CASING NOTE: 2X6 EXT. WALLS U.N.O. 2X4 INT. WALLS U.N.O. HEADER SPANS: UP TO 4'-11'' = 1 TRIMMER 5'-0'' AND BIGGER = 2 TRIMMERS UNLESS NOTED OTHERWISE INDICATES LOCATION OF SOLID BRG.32x60FGLS.TUB / SH (152 SQ. FT.) OWNERS BDRM. 9' CLG. / CARPET (12'-6"x16'-0") (164 SQ. FT.) SMOKECM / SD 2 - 4072 SH @ 8' DN 17 R (10" T., 7-3/4" MAX. R.) 2x6 8/0 H. SOFFIT * BEADBD. CLG.ATTICACCESSAPPROX. 512 SQ. FT. MUDRM. 9' CLG. / LVP BENCH / APPROX. 9'-0'' CLG. @ MAIN LEVEL APPROX. 1,762 SQ. FT. HOOKS3068 MTL.3080 MTL.R&SHR&SH26 6 8 3/0 x 8/0 SRO2868(5) SH. (5) SH. 9' CLG. / LVP 2668R&SHR&SH 36" VAN. LIN.CAB. 3 0 6 8 3068 PKT.FLDG. C'TOP.(OPEN UNDER)2 - 4072 SH @ 8' 30" VAN. DINING 9' CLG. / LVP FLR.10'-0" x 9'-0" (90 SQ. FT.) 3672 SH @ 8'3672 SH @ 8'4872 PICT. @ 8'MANUF. TRUSSES24 O.C.40'-0" 15'-0"11'-0" 8'-10"11'-6"69'-0"60'-0"5'-5 1/2"5'-7 3/4"5'-8"12'-8 3/4"7"3'-11"5'-2 1/2"4'-4 3/4"6'-2 1/4"6'-6 1/2"69'-0"5'-0"31'-0"27'-0"14'-4"16'-8"3'-2"9'-0 1/2"11'-6"5'-0"5'-6"16'-6"10'-6"40'-0" 6'-0" 20'-0" 10'-6"10'-6" RADON VENT PA SD SMOKECM / 2'-4 1/4"1'-10 1/2"2424 PICT. @ 8'2424 PICT. @ 8'2'-0 1/2"2'-0 1/2"INDICATED STONE WHERE2448 SH @ 8'5'-0"WD. STEP 2'-9" 4'-4"3'-9"2'-9"5'-4 3/4"6'-1 1/4" 6'-1 1/4" 4'-8 3/4"12'-11 1/4" 7'-0 3/4" 2'-0" 1'-4" 7'-10"15'-0 1/2" 2'-7 1/2"2'-4"3'-10 1/2"2'-8 3/4"10'-0"5'-0"12" CANT.11'-4"5'-2"6'-8"7'-8"4'-0"12'-8"3'-9"3'-10"3'-5"3'-5"3'-0"2'-8"3'-4"2-2x102-2x102-2x102-2x104 1/2"4 1/2" 8'-10 1/2"MANUF. TRUSSES24 O.C.FP CHASEFALSE 2-9 1/2" LSL (CONT.)2-9 1/2" LSL 2-2x10 (2) TR (2) TR 2-2x10 2-9 1/2" LSL P.H. TR TB 3068 PKT. 42" W. CONC. SIDEWALK PORCH CONCRETE MANUF. TRUSSES 24 O.C. * BEADBD. CLG. RECESSED STEP 5/0 BI-PASS R&SH 2 6 6 82668 2 - 4072 SH @ 8'2-9 1/2" LSL13'-11 3/8"2'-5 1/2"BEDRM. #3 / OFFICE 9' CLG. / CARPET (12'-3"x10'-11") (136 SQ. FT.) 4'-1"8'-11"246813'-0" 6'-6"6'-6"6'-0"6'-0"5'-8"7'-3"6'-9" 14'-0"3'-0"11 3/4"9'-4"2x6 2x63'-11 1/4"8'-11" SD 6'-3"2x63'-6"5'-0"3'-6"6'-0" 21'-0" 20'-0" 7'-0" GIRDER TRUSS 18" LP COL. 10'-2"2-9 1/2" LSL (DR)LP SOFFIT 2x4 FRAMING 3"1'-2" 2-9 1/2" LSL (DR) 1'-2"3"1'-2"3-9 1/2" LSL (DR)5'-10"3"1'-2"BUILT-INCAB.BUILT-INCAB.BASE BUFFET CAB.2668LEDGESTONEFLOOR TO CLG.2424 PICT. @ 8'2-2x103'-8"2424 PICT. @ 8'2-2x109'-0"4'-0"4'-9"3068 PKT.BASE / LTUB4 4 4 4 8 8 4 4 4 4 PFH PFH Tempered 5 7 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X17995 GREFORD LN., LAKEVILLELOT 14, BLOCK 6, SUMMER'S CREEKHAMPTON 1760 PLANMARK ELLIOTT HOMES4-26-2021 SELECT 6-24-2021 PERMIT OF SHEET SCALE: 1/4" = 1'-0" SECTION1 5 N.T.S. HOUSE / DECK CONNECTION DETAIL4 5 R-5 THERMAX AT INTERIOR FOUND. AS REQUIRED 3/4" T & G FLOOR NOTE: SUBFLOOR JOINTS SHALL BESTAGGERED FROM FLOOR TRUSS ORJOIST JOINTS R=0.61 R=49.00 R=50.25 R=0.58 R=.061 TOTAL TRUSSES - 24" OC BLOWN INSULATION INTERIOR AIR FILM VAPOR BARRIER 15/32" OSB SHTG. 15# FELT EXTERIOR AIR FILM ICE AND SNOW SHIELD 30 YR. ARCH. ASPHALT SHINGLES 5/8" GYP BD ALUM. SOFFIT & FASCIA 1/2" GYP BD INTERIOR AIR FILM TOTAL SIDING PER SPECS 2x6 STUDS 16" OC R=1.06 R= R= R=21.00 R=0.45 R=0.17 R=23.36 VAPOR BARRIER FULL WALL BATT INSUL. EXTERIOR AIR FILM R=0.68 7/16" OSB SHTG. 8" AGGREGATE6 MIL POLY. LAP SEAMS 12"1'-4"HEEL HT.1/2" GYP. SHEATHING ON GARAGE WALLS5/8" TYPE 'X' GYP. BD. ON GARAGE CEILS. 18" FLOOR TRUSSES1'-6 3/4"9'-1 1/8"T.O. LOOKOUT T.O. SUBFLR. T.O. PLATE TRUSSES @ 24" O.C. (DESIGNED BY MFR) 6 12 R-49 INSUL.9'-4"GARAGE 4" SLOPED CONC. W/ REBAR PER ENGINEERS REPORT 9'-4" POURED WALL DRAIN TILE 10" POURED WALL R-5 INSUL. ATINTERIOR FOUND.9'-9 1/8"O. BATH OWNERS BDRM. 20x8 CONC. FTG.16x8 CONC. FTG. 16x8 CONC. FTG. SPRAY FOAM RIM 8'-2" +/-FOUND. HELD IN 2" FOR INSULATION TYP. NOTE: (INSUL. FLUSH w/ SHTG.) CANT. 2x8 SILL PLT. 1-1/2"3 1/2" CONC. FLOOR 2" RIGID INSULATION R-10 w/ WATCHDOG WATERPROOF COATING AROUND HOUSE FOUND. 20x8 CONC. FTG.8 1/4"6"HEEL HT.6 12 11"HEEL HT.3'-6"FUT. BDRM. #5 R.I. BATH 8 1/4"3'-6"7'-8"6 12 NOTE: TOP HUNG TRUSSES AT FRONT OF HOME (9'-4" H. FDN. WALL) SPRAY FOAM RIM 4"12"6 3/4" +/-JOIST W/ 2-3/8" LAG BOLTS ICE & WATER EXTENDS5" UP SHEATING UNDER INSTALL TOP OF LEDGER 3 5/8" BELOW TOP OF 3/4" SUBFLOOR (THIS ALLOWS 5/4 X 4 THRESHOLD AT DOOR) HANGER TREATED 2X10 LEDGER RUN HOUSE WRAP BEHIND LEDGER (LEAVE 6" TAIL @ TOP, BOTTOM, & SIDES) HOUSEWRAP @ 24" O.C. -OR- EMBED 2" MIN. 8 INCHES O.C. MAX OR EQUAL, W/ "LEDERLOK" FASTENERS CONT. 2X4 RIBBON SPRAY FOAM INSUL. R-21 MIN. RIM BOARD TREATED JOIST JOIST RIM BD. SKIRT 1" HOUSE END OF DECK HOUSE LATERAL LOAD SIMPSON DTT1Z DECK-TO CONNECTOR - (4) PER DECK OR 8-10DX1 1/2" NAILS 6-SD#9X1 1/2" SCREWS HDG WASHER OR SDWH 3/8" HDG LAG SCREW WITH TIMBER-HEX HDG SCREW (SHOWN) INTO TOP PLATE, STUDS, OR HEADER CONT. 2X8 RIBBON DRAIN TILE 3/4" WASHED ROCK CONTINUOUS UNDER SLAB0'-16" SILT FABRIC FOUNDATION WALL CONC. FTG. 4" DRAIN TILE 2 SCALE: NO SCALE5 TOP OF FDN.RIM DETAIL3 SCALE: NO SCALE5 2" RIGID INSULATION R-10 w/ WATCHDOG WATERPROOF COATING AROUND HOUSE FOUND. 2" RIGID INSULATION R-10 w/ WATCHDOG WATERPROOF COATING AROUND HOUSE FOUND. 2x8 TRTD. SILL SHEATHING FLUSH WITH INSULATION NOTE: FOUNDATION TO BE HELD IN 2" FROM SHEATHING & OUTSIDE DIMENSIONS. CANTED 1-1/2" 6 7 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X17995 GREFORD LN., LAKEVILLELOT 14, BLOCK 6, SUMMER'S CREEKHAMPTON 1760 PLANMARK ELLIOTT HOMES4-26-2021 SELECT 6-24-2021 PERMIT OF SHEET SCALE: 1/4" = 1'-0" SECTION1 6 N.T.S. PORTAL FRAME DETAIL2 6 N.T.S. RADON DETAIL3 6 SIMPSON STRONG TIE Ab46z HEADER HURRICANE CLIP ATTACHEDTO COLUMN& BEAM 11 7/8" OSB STRINGER W/ 2X4 BRACING 10 1/2" BULLNOSE LSL TREAD 1X8 PINE S4S RISER NOTE: MAX RISE= 7 3/4" MIN. RUN= 10" 6'-8" CLEAR HEADROOM BATH 2GREAT RM. 3/4" T & G FLOOR NOTE: SUBFLOOR JOINTS SHALL BESTAGGERED FROM FLOOR TRUSS ORJOIST JOINTS 8" AGGREGATE6 MIL POLY. LAP SEAMS 12" 18" FLOOR TRUSSES9'-1 1/8"T.O. SUBFLR. T.O. PLATE TRUSSES @ 24" O.C. (DESIGNED BY MFR) R-49 INSUL.9'-4"W/ REBAR PERENGINEERS REPORT 9'-4" POURED WALL DRAIN TILE 10" POURED WALL R-5 INSUL. ATINTERIOR FOUND. 20x8 CONC. FTG.16x8 CONC. FTG. SPRAY FOAM RIM 8'-2" +/-FOUND. HELD IN 2" FOR INSULATION TYP. NOTE: (INSUL. FLUSH w/ SHTG.) CANT. 2x8 SILL PLT. 1-1/2" 3 1/2" CONC. FLOOR 2" RIGID INSULATIONR-10 w/ WATCHDOG WATERPROOF COATING AROUND HOUSE FOUND. PORCH 18" SQ.LP COLUMN 20x8 CONC. FTG. MECH. / STORAGEFAMILY ROOM 3'-6"KITCHEN 8 1/4"4x4 TRTD. COL. LP TRIM 2 5 3 5 ALUM. SOFFIT & FASCIA 1'-4"HEEL HT.6 12 6 12 R-5 THERMAX AT INTERIOR FOUND. AS REQUIRED1'-6 3/4"T.O. LOOKOUT 4" LEDGE NOTE: TOP HUNG TRUSSES AT FRONT OF HOME (9'-4" H. FDN. WALL) CONC. STOOP6 3/4" +/-4"SPRAY FOAM RIM 16RFLEX ROOMBEDRM. #3 / OFFICE 6 12 SIMPSON STHD14 HOLD DOWN SIMPSON LSTA36 STRAP ON INSIDE FACE OF WALL 5/8" ANCHOR BOLT 1/2" OSB SHEATHING HEADER- SEE PLAN FOR SIZE FASTEN SHEATHING TO HEADER WITH 8d COMMON OR GALVANIZED BOX NAILS IN 3" GRID PATTERN ASSHOWN, AND 3" O.C. IN ALL FRAMING MEMBERS TYP. SHEATHING SPLICE (IF NEEDED) MUST BE LOCATED WITH-IN 24" OF THE MID HEIGHT OF THE DOOR OPENING. PROVIDE 2-2X6BLOCKING BEHIND SPLICE FASTEN TOP PLATE TO HEADER WITH2 ROWS OF 16d SINKER NAILS 3" O.C. BLOCK BACK SIDE OF HEADER FLUSH WITH STUDSAT STRAP LOCATIONS UNEXCAVATED SOIL ALL SLABS WILL HAVE A MIN. 4" CLEAN AGGREGATE, COVERED BY 6 MIL POLY. THIS POLY WILL HAVE 12" LAP AT ALL SEAMS. ALL TEARS OR PUNCTURES WILL BE SEALED OR COVERED BY POLY. ALL OPENINGS WILL BE SEALED USING POLYURETHANE CAULK OR ELASTOMERIC SEALANT AT ALL OPNGS. AN INSTALLED 3" GASTIGHT PVC PIPE WILL BE CONNECTED TO THE DRAIN TILE SYSTEM. A "T" FITTING WILL BE INSTALLED WITH 10 L.F. EACH END OF THE "T", OF PERFORATED PIPE, INTO THE DRAIN TILE SYSTEM. THE SHORTEST ROUTE WILL BE USED TO EXIT THE ROOF SYSTEM, WITH A MAX. OF 2 90 DEGREE ELBOWS. IN UNCONDITIONED AREAS, THE RADON EXHAUST PIPE WILL BE INSULATED WITH AN R4 SLEEVE. THIS PIPE WILL BE LABELED "PASSIVE RADON" AT ALL ACCESSIBLE LOCATIONS. AT ROOF EXIT LOCATIONS, MAINTAIN A 10' DISTANCE TO ANY WINDOW LOCATION, 2' BELOW EXHAUST POINT AND ANY ADJACENT STRUCTURE. THE LOCATION OF THE EXIT POINT, IN TRUSS AREA, WILL BE CLEAR OF ANY OBSTRUCTIONS WITHIN 24" HORIZONTALLY AND 36" VERTICALLY. INSTALL AN OUTLET AND PULL CHORD LIGHT FOR FUTURE EXHAUST FAN ADDITION. SCALE: 1/4" = 1'-0" MAIN FLR. ELECTRICAL PLAN 7 7 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X17995 GREFORD LN., LAKEVILLELOT 14, BLOCK 6, SUMMER'S CREEKHAMPTON 1760 PLANMARK ELLIOTT HOMES4-26-2021 SELECT 6-24-2021 PERMIT OF SHEET SCALE: 1/4" = 1'-0" LOWER LEVEL ELECTRICAL PLAN TVABV. FP.NOTE: TECH TUBE TVW.P.S3S3LTS.PENDANT 3 SS C/L 7'-6"3'-2"5'-9 1/2"DW GAS RANGEMICRO ABV. LNDRY. DRYERWASHER (VENT TO OUTSIDE) REF. KITCHEN GREAT ROOM FOYER O. BATH GARAGE O. CLST OWNERS BDRM. SMOKE CM / SD ATTICACCESSMUDRM. DINING GDO G.F.I.P. S G.F.I.P.G.F.I.P.G.F.I.P.W.P. S SS 3 S3S3S3S3SS3 S3S SS3 SSS3DISP S SS3 S TO LIGHT S G.F.I.P.G.F.I.P. SD FLEX ROOM S SMOKECM / BEDROOM 3/OFFICE BATH 2SG.F.I.P.SSD S SPORCH S SNOTE: RGH.-IN FOR FUT. LED UC.TAPE LITES W.P.W.P.SOFFITIN C/L FLOOR OUTLET C/LG.F.I.P. CAB.INSIDE 3rd/4th SH. HT.IN BETWEEN ETHERNET ETHERNET ETHERNET MINI-RECESS MINI-RECESS S S MINI-RECESS S DUPLEX CONVENIENCE OUTLET DUPLEX OUTLET ABOVE COUNTER WEATHERPROOF DUPLEX OUTLET HALF-SWITCHED DUPLEX OUTLET DUPLEX OUTLET IN FLOOR 220 VOLT OUTLET WALL SWITCH THREE-WAY SWITCH FOUR-WAY SWITCH CEILING MOUNTED INCANDESCENT LIGHT FIXTURE WALL MOUNTED INCANDESCENT LIGHT FIXTURE RECESSED INCANDESCENT LIGHT FIXTURE LIGHT FIXTURE WITH PULL CHAIN TRACK LIGHT FLOURESCENT LIGHT FIXTURE EXHAUST FAN EXHAUST FAN/LIGHT COMBINATION CHIMES (OPTIONAL) SMOKE DETECTOR TELEPHONE (OPTIONAL) TELEVISION (OPTIONAL) THERMOSTAT ELECTRIC METER ELECTRIC PANEL SPEAKER (OPTIONAL) TV T M CH SD P.C. S S S 4 3 W.P. ELECTRICAL KEY DUPLEX OUTLET (GROUND FAULT PROTECTED)G.F.I.P. RECESSED INCANDESCENT EYE BALL FIXTURE CARBON MONOXIDE DETECTORCM GARAGE DOOR OPENER OUTLETGDO FLUORESCENT LIGHT PER SPEC FAN/LIGHT COMBO PREWIRE, PROVIDE ADEQUATE SUPPORT 4 BULB FIXTURE 3 BULB FIXTURE 200 AMP SERVICE LIGHTING PACKAGE: T.B.D. LINE TO DRYER: T.B.D.G.F.I.P.EXCH.AIRFURN F.D. WH MECH. / STORAGE WS BDRM. #5 FAMILY ROOM L.L. BATH SUMP H20 OPT. SMOKECM / S S3S TO LIGHT A/C UNIT w/ BRACKET G.F.I.P. SMOKECM / SD S 3S3 SSSG.F.I.P.SSTVTV FLEX G.F.I.P.G.F.I.P.G.F.I.P.LOCATIONVERIFY LOCATIONVERIFY LOCATIONVERIFY ZONE FURNACE AS REQ'D. * PROVIDE ELEC. FOR DUAL ETHERNET ETHERNET ETHERNET ETHERNET BW 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X17995 GREFORD LN., LAKEVILLELOT 14, BLOCK 6, SUMMER'S CREEKHAMPTON 1760 PLANMARK ELLIOTT HOMES4-26-2021 SELECT 6-24-2021 PERMIT SHEETN.T.S. MAIN LEVEL BRACEWALL2 BW N.T.S. BRACEWALL DETAILS3 BW N.T.S. LOWER LEVEL BRACEWALL1 BW GARAGE PORTAL FRAMING PER BUILDING CODE IRC R602.10.6.4 BRACED WALL METHOD CS-WSP 3'-2" PANEL4'-0" PANEL4'-0" PANEL4'-0" PANEL4'-0" PANEL4'-0" PANELBRACED WALLLINE 1BRACED WALLLINE A BRACED WALLLINE CBRACED WALLLINE 24'-0" PANEL4'-0" PANEL4'-0" PANEL4'-0" PANEL3'-2" PANEL 3'-5" PANEL 3'-5" PANEL3'-1" PANEL BRACED WALL LINE B 8'-0" GYP. PANEL 8'-0" GYP. PANEL 1'-8" PANEL 1'-0" PANEL 3'-11" PANEL LNDRY. KITCHEN GREAT ROOM FOYER O. BATH GARAGE O. CLST OWNERS BDRM.ATTICACCESSMUDRM. DINING FLEX ROOM BEDROOM 3/OFFICE BATH 2 PORCH MIN. 3''x11 1/4'' NET HEADER(STEEL HDR. PROHIBITED) EXTENT OF HEADER W/ SINGLE PORTAL FRAME ONE BRACED WALL PANEL 10'-0'' MAX. HEIGHT(TOP OF HDR.)TOP OF FDN.TOP OF CONC FLOOR AT OPENING MIN. 2-2x4 FRAMING STUD POST CONTINUOUS HEADER WITH DOUBLE PORTAL FRAMES TWO BRACED WALL PANELS 6' TO 18' OPENING FASTEN TOP PLATE TO HEADER W/ 2ROWS OF 16d SINKER NAILS @ 3'' O.C. TYP. 1000 LB. STRAP OPPOSITE SIDE OF SHEATHING FASTEN SHEATHING TO HEADER W/ 8dCOMMON OR GALV. BOX NAILS IN 3'' GRIDPATTERN SHOWN AND 3'' O.C. IN ALL FRAMING(STUDS, BLOCK'G AND SILLS)TYP. MIN. WIDTH PER TABLE R602.10.5 3/8'' MIN. WOOD STRUCTURAL PANEL SHEATH'G. MIN. 2-2x4 MIN. 4200 LB. TIE DOWN DEVICE(EMBED INTOFOUNDATION AND NAILED INTO FRAMING MIN. (2) 1/2'' DIA. ANCHOR BOLT INSTALLED PER R403.1.6 W SEE LEFT FORTYP. PORTAL FRAME CONST. FOR A PANEL SPLICE (IF NEEDED) PANELEDGES SHALL BEBLOCKED AND OCCUR WITHIN 24'' OF MID-HEIGHT. ONE ROW OFTYP. SHEATH'G. TO FRAMING NAILING ISREQUIRED.IF 2x4 BLOCK'G. IS USED THE 2x4'S MUST BE NAILEDTOGETHER W/ 3 16dSINKER NAILS W/ 2''x2''x3/16'' PLATE WASHER12'-0'' MAX. HEIGHT(TOP OF WALL)FULL HEIGHT OF WALL - SEE TO RIGHT FOR SPLICESPONY WALL HT.EXTENT OF HEADER TENSION STRAP PERTABLE R602.10.6.4 (ON OPPOSITE SIDE OFSHEATHING ANCHOR BOLTS PER SECTIONR403.1.6 BRACED WALL LINECONTINUOUSLY SHEATHED WITHWOOD STRUCTURALPANELS TOP OF FLOOR AT OPENING FLOOR FRAMING ASSEMBLY PER PLAN W/ WOOD STRUCTURAL PANEL SHEATHING TOP OF FLOOR AT OPENING FLOOR FRAMING ASSEMBLY PER PLAN WOOD STRUCTURAL PANEL SHEATHINGTO TOP OF BAND OR RIM JOIST NAIL SOLE PLATE TO FLRFRAMING PER TABLE R602.3(1) (2) FRAMING ANCHORS APPLIED ACROSS SHEATHING JOINT WITH A CAPACITY OF670# IN HORIZ. AND VERT. DIRECTIONS SEE LEFT FORTYP. PORTAL FRAME CONST. ON CONCRETE FOUNDATION ON RAISED WOOD FLOOR - FRAMING ANCHOR OPTION TOP OF FLOOR AT OPENING FLOOR FRAMING ASSEMBLY PER PLAN W/ WOOD STRUCTURAL PANEL SHEATHING TOP OF FLOOR AT OPENING FLOOR FRAMING ASSEMBLY PER PLAN WOOD STRUCTURAL PANEL SHEATHINGTO TOP OF BAND OR RIM JOIST NAIL SOLE PLATE TO FLRFRAMING PER TABLE R602.3(1) SEE LEFT FORTYP. PORTAL FRAME CONST. ON RAISED WOOD FLOOR - OVERLAP FLOOR OPTION MIN. OVERLAP 9 1/4''WOOD STRUCTURAL PANEL SHEATHINGCONTINUOUS OVER BAND OR RIM JOIST MIN. OVERLAP 9 1/4''ATTACH TO RIM/BAND JOIST W/ 8dCOMMON NAILS AT 3'' O.C. AS SHOWN DBL TOP PLATE BOTTOM PLATE STUDS AT 16'' O.C. W/ 6d NAILS @ 6'' O.C. 4'-0"8'-0'' MIN., SEE PLANINTERMEDIATE 6''3"W/ 6d NAILS @ 3'' O.C. EDGES NAILED BDRM. #5 FAMILY ROOM BRACED WALLLINE D 4'-0" PANEL 4'-0" PANEL 4'-0" PANEL 4'-0" PANEL Builders Associaton of Minnesota version 101014 New Construction Energy Code Compliance Certificate Place your logo here Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. Date Certificate Posted Mailing Address of the Dwelling or Dwelling Unit City 17995 Gresford Ln Lakeville Name of Residential Contractor MN License NumberMark Elliot Homes BC665904 THERMAL ENVELOPE RADON CONTROL SYSTEM Insulation Location Total R-Value of all Types ofInsulationType: Check All That Apply X Passive (No Fan)Non or Not ApplicableFiberglass, BlownFiberglass, BattsFoam, Closed CellFoam Open CellMineral FiberboardRigid, Extruded PolystyreneRigid, IsocynurateActive (With fan and monometer or other system monitoring device) Location (or future location) of Fan: Attic Other Please Describe Here Below Entire Slab Foundation Wall R-15 Interior Walls Perimeter of Slab on Grade Rim Joist (1st Floor)R-20 X Interior Rim Joist (2nd Floor+) Wall R-21 X Ceiling, flat R-49 X Attic Ceiling, vaulted N/A Bay Windows or cantilevered areas R-30 X Floors over unconditioned area N/A Describe other insulated areas Building envelope air tightness:Duct system air tightness: Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces Average U-Factor (excludes skylights and one door) U: 0.29 X Not applicable, all ducts located in conditioned space Solar Heat Gain Coefficient (SHGC):0.28 R-value MECHANICAL SYSTEMS Make-up Air Select a Type Appliances Heating System Domestic Water Heater Cooling System X Not required per mech. code Fuel Type NAT Gas NAT Gas Electric Passive Manufacturer Bryant Rheem Bryant Powered Model 91250036060 PROG50 113ANA024 Interlocked with exhaust device. Describe: Rating or Size Input in BTUS:60,000 Capacity in Gallons:50 Output in Tons:2 Other, describe: Efficiency AFUE or HSPF%92 0.7 SEER /EER 13 SEER R4 10 Location of duct or system: Residential Load Calculation Heating Loss Heating Gain Cooling Load 59,633 23,661 23,661 Cfm's X " round duct OR MECHANICAL VENTILATION SYSTEM " metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Combustion Air Select a Type X Not required per mech. code Select Type Passive Heat Recover Ventilator (HRV) Capacity in cfms:Low: High:Other, describe: X Energy Recover Ventilator (ERV) Capacity in cfms:Low: 50 High:140 Location of duct or system: Balanced Ventilation capacity in cfms:Mechanical Room Location of fan(s), describe: Cfm's Capacity continuous ventilation rate in cfms:6" " Flex duct OR Total ventilation (intermittent + continuous) rate in cfms: " metal duct NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. A National Pollutant Discharge Elimination System (NPDES) Construction Stormwater Permit is required for “Construction activity that results in land disturbance of equal to or greater than one (1) acre or if a project is part of a common plan of development that will ultimately disturb greater than one (1) acre,” (NPDES Permit, Section 1.2). Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ *Primary Company Contact: _________________________________________________________________ *Should a site be deemed noncompliant, this individual will be notified Phone #: ____________________________ Email: ______________________________________________ If you are not covered under a NPDES Construction Stormwater Permit administered by the Minnesota Pollution Control Agency (MPCA), an erosion and sediment control plan MUST be approved as part of the residential building permit application. “Permittees must ensure a trained person will inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than ½ inch in 24 hours,” (NPDES Permit, Section 11.2). The City of Lakeville reserves the right to request weekly inspection logs. The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name: ____________________________________ Company: ___________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: __________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed I understand the above information to be accurate and I have read, understood, and accepted all terms and conditions of the NPDES Permit (MN R 100001). Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 Nick Reimler X08/09/21 KP