Loading...
HomeMy WebLinkAboutLA198289 18138 Garland Path App & FormsRESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: 20195 Holyoke Avenue, Lakeville, MN 55044 952-985-4400  952-985-4499 fax www.lakevillemn.gov Sewer & Water Tie Card Address:________________________________________ Contractor:______________________________________ Permit Number:__________________________________ Final Date:________________ Street Drain-Tile:______ Size of Water Service: 1” Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME OF SEWER & WATER INSPECTION Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Pronto Heating and AC Sable Eden Prairie, MN 55344 Page 1 Project Report General Project Information Project Title:Sable Designed By:Doug Dormanen Project Date:7-12-2021 Client Name:Brandl Anderson Company Name:Heating & Cooling Two Inc Company Representative:Doug Dormanen Design Data Reference City:Minneapolis/St. Paul AP, Minnesota Building Orientation:Front door faces East Daily Temperature Range:Medium Latitude:44 Degrees Elevation:834 ft. Altitude Factor:0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter:-15 -12.38 n/a n/a 70 n/a Summer:92 73 41%50%72 35 Check Figures Total Building Supply CFM:926 CFM Per Square ft.:0.405 Square ft. of Room Area:2,289 Square ft. Per Ton:943 Volume (ft³):18,425 Building Loads Total Heating Required Including Ventilation Air:54,503 Btuh 54.503 MBH Total Sensible Gain:23,051 Btuh 79 % Total Latent Gain:6,072 Btuh 21 % Total Cooling Required Including Ventilation Air:29,123 Btuh 2.43 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\Brandl Anderson- Sable.rh9 Wednesday, November 24, 2021, 11:18 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Pronto Heating and AC Sable Eden Prairie, MN 55344 Page 2 Miscellaneous Report System 1 Lower Level Input Data Outdoor Dry Bulb Outdoor Wet Bulb Outdoor Rel.Hum Indoor Rel.Hum Indoor Dry Bulb Grains Difference Winter:-15 -12.38 100%n/a 70 n/a Summer:92 73 41%50%72 35.16 Duct Sizing Inputs Main Trunk Runouts Calculate:Yes Yes Use Schedule:Yes Yes Roughness Factor:0.00300 0.01000 Pressure Drop:0.1000 in.wg./100 ft.0.1000 in.wg./100 ft. Minimum Velocity:0 ft./min 0 ft./min Maximum Velocity:900 ft./min 750 ft./min Minimum Height:8 in.6 in. Maximum Height:10 in.0 in. Outside Air Data Winter Summer Infiltration Specified:0.220 AC/hr 0.110 AC/hr 68 CFM 34 CFM Infiltration Actual:0.000 AC/hr 0.000 AC/hr Above Grade Volume:Cu.ft.Cu.ft.X 18,425 X 18,425 0 Cu.ft./hr 0 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration:0 CFM 0 CFM Total Building Ventilation:154 CFM 154 CFM ---System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 21.35 = (1.10 X 0.970 X 20.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 23.19 = (0.68 X 0.970 X 35.16 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 90.72 = (1.10 X 0.970 X 85.00 Winter Temp. Difference) Winter Infiltration Specified:0.220 AC/hr (68 CFM), Construction: Semi-Tight Summer Infiltration Specified:0.110 AC/hr (34 CFM), Construction: Semi-Tight C:\ ...\Brandl Anderson- Sable.rh9 Wednesday, November 24, 2021, 11:18 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Pronto Heating and AC Sable Eden Prairie, MN 55344 Page 3 Load Preview Report Scope Net Ton ft.² /Ton Area Sen Gain Lat Gain Net Gain Sen Loss Sys Htg CFM Sys Clg CFM Sys Act CFM Duct Size Building 2.43 943 2,289 23,051 6,072 29,123 54,503 543 926 926 System 1 2.43 943 2,289 23,051 6,072 29,123 54,503 543 926 926 18x10 Ventilation 3,287 3,572 6,859 13,970 Zone 1 - Clg.: 19%, Htg.: 26%808 4,563 700 5,263 10,683 143 214 214 6x9 1-Lower Level 808 4,563 700 5,263 10,683 143 214 214 4--6 Zone 2 - Clg.: 51%, Htg.: 45%800 12,162 600 12,762 18,427 247 570 570 12x10 2-Main Level 160 1,329 0 1,329 4,486 60 62 62 1--6 4-Great Room/ Dining/ Kitchen 640 10,833 600 11,433 13,941 187 507 507 8--6 Zone 3 - Clg.: 30%, Htg.: 28%681 7,240 1,200 8,440 11,423 153 339 339 8x10 3-Upper Level 681 7,240 1,200 8,440 11,423 153 339 339 5--6 Sum of room airflows may be greater than system airflow because Sum of room airflows may be greater than system airflow because system has multiple zones. C:\ ...\Brandl Anderson- Sable.rh9 Wednesday, November 24, 2021, 11:18 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Pronto Heating and AC Sable Eden Prairie, MN 55344 Page 4 System 1 Lower Level Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain 4A-6-d: Glazing-Double pane low-e (e = 0.20 or less), high performance, sliding glass door, e=0.05 on surface 2, any frame, U-value 0.33, SHGC 0.33 249 6,985 0 8,944 8,944 11N: Door-Metal - Polystyrene Core, U-value 0.35 39 1,161 0 423 423 12E-0bm: Wall-Frame, R-19 insulation in 2 x 6 stud cavity, no board insulation, brick finish, metal studs, U-value 0.103 2456.8 21,509 0 4,150 4,150 15B0-10sf-8: Wall-Basement, , R-10 board insulation to floor, no interior finish, 8' floor depth, U-value 0.05, above grade U-value 0.083 1040 5,004 0 283 283 16CR-44: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Vented Attic with Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-44 insulation, U-value 0.022 1321 2,470 0 1,308 1,308 21A-20: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 20' wide, U-value 0.027 808 1,854 0 0 0 20P-30: Floor-Over open crawl space or garage, Passive, R-30 blanket insulation, any cover, U-value 0.035 521 1,550 0 274 274 Subtotals for structure:40,533 0 15,382 15,382 People:8 1,600 2,400 4,000 Equipment:900 1,200 2,100 Lighting:0 0 0 Ductwork:0 0 0 0 Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Ventilation: Winter CFM: 154, Summer CFM: 154 13,970 3,572 3,287 6,859 Exhaust: Winter CFM: 60, Summer CFM: 60 AED Excursion:0 0 782 782 System 1 Lower Level Load Totals:54,503 6,072 23,051 29,123 Check Figures Supply CFM:926 CFM Per Square ft.:0.405 Square ft. of Room Area:2,289 Square ft. Per Ton:943 Volume (ft³):18,425 System Loads Total Heating Required Including Ventilation Air:54,503 Btuh 54.503 MBH Total Sensible Gain:23,051 Btuh 79 % Total Latent Gain:6,072 Btuh 21 % Total Cooling Required Including Ventilation Air:29,123 Btuh 2.43 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\Brandl Anderson- Sable.rh9 Wednesday, November 24, 2021, 11:18 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Pronto Heating and AC Sable Eden Prairie, MN 55344 Page 5 System 1 Room Load Summary No Room Name Area SF Htg Sens Btuh Min Htg CFM Run Duct Size Run Duct Vel Clg Sens Btuh Clg Lat Btuh Min Clg CFM Act Sys CFM ---Zone 1--- 1 Lower Level 808 10,683 143 4-6 272 4,563 700 214 214 Zone 1 subtotal 808 10,683 143 4,563 700 214 214 ---Zone 2--- 2 Main Level 160 4,486 60 1-6 317 1,329 0 62 62 4 Great Room/ Dining/ Kitchen 640 13,941 187 8-6 323 10,833 600 507 507 Zone 2 subtotal 800 18,427 247 12,162 600 570 570 ---Zone 3--- 3 Upper Level 681 11,423 153 5-6 346 7,240 1,200 339 339 Zone 3 subtotal 681 11,423 153 7,240 1,200 339 339 Ventilation 13,970 3,287 3,572 System 1 total 2,289 54,503 543 23,051 6,072 926 926 System 1 Main Trunk Size:18x10 in. Velocity:741 ft./min Loss per 100 ft.:0.087 in.wg Note: Since the system is multizone, the Peak Fenestration Gain Procedure was used to determine glass sensible gains at the room and zone levels, so the sums of the zone sensible gains and airflows for cooling shown above are not intended to equal the totals at the system level. Room and zone sensible gains and cooling CFM values are for the hour in which the glass sensible gain for the zone is at its peak. Sensible gains at the system level are based on the "Average Load Procedure + Excursion" method. Cooling System Summary Cooling Tons Sensible/Latent Split Sensible Btuh Latent Btuh Total Btuh Net Required:2.43 79% / 21%23,051 6,072 29,123 Equipment Data Heating System Cooling System Type:Natural Gas Furnace Standard Air Conditioner Model: Indoor Model: Brand: Efficiency:0 AFUE 0 SEER Sound:0 0 Capacity:0 Btuh 0 Btuh Sensible Capacity:n/a 0 Btuh Latent Capacity:n/a 0 Btuh C:\ ...\Brandl Anderson- Sable.rh9 Wednesday, November 24, 2021, 11:18 AM