Loading...
HomeMy WebLinkAboutLA198238 19814 Henning Ave Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov CANNOT HOOK TO CITY SEWER/WATER RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: 20195 Holyoke Avenue, Lakeville, MN 55044 952-985-4400  952-985-4499 fax www.lakevillemn.gov Sewer & Water Tie Card Address:________________________________________ Contractor:______________________________________ Permit Number:__________________________________ Final Date:________________ Street Drain-Tile:______ Size of Water Service: 1” Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME OF SEWER & WATER INSPECTION LOT 4, BLOCK 3, BERRES RIDGE 7TH ADDITION*ALL DOOR & WINDOW HEADERSTO BE S.P.F. #2 OR BETTERRESIDENCE FOR:written consent of Planco MN, Inc. modified or used in any redesign without the priormay not be assigned or copied, and may not bemay not be re-used for any additional structures,structure. Planco MN reserves all rights. These planslicense is granted to use these plans to build oneCopyright for these drawings is owned by Planco MN,Planco MN, Inc.cZACH & CLAIRE ANDERSON#21-084SMA182021STONE COTTAGE CONSTRUCTION, INC. 19814 HENNING AVE, LAKEVILE FRONT ELEVATION 1/4" = 1'-0" 16x8 OVH. DR.9x8 OVH. DR.8127127124" TRIMVINYLB & BVINYLB & B6128126"WOOD PORCHVINYL SIDING4" TRIM9' POURED FOUNDATION9' CEILING @ FIRST FLOORTOTAL2nd FLR.1st FLR.1,149 SQ. FT.1,254 SQ. FT.2,403 SQ. FT.THERMO-TECHPATIO DOORMARVIN ESSENTIALSTONE AS SHOWNFRONT & SIDES4/1210/12(2) BRACKETSVINYLB & BWINDOWS4" BOXEDCEDAR BEAM4" TRIMFRONT ONLY4" VINYL SIDINGSIDES & REARVINYL B & BFRONT ONLYTOTALBSM'T553 SQ. FT.2,956 SQ. FT.12x12 CEDARCEDAR COLUMN9x8 OVH. DR.VINYLB & B7121'-6"FRONT ONLYGRIDS IN WDWS. LEFT ELEVATION 1/8" = 1'-0" 812712SIDINGVINYL 1'-0"1'-9"812SIDINGVINYL LPB & B RIGHT ELEVATION 1/8" = 1'-0" 7128128123'-4"STAIRLANDINGSIDINGVINYL VINYLCORNERSWDW. WELLEGRESS REAR ELEVATION 1/8" = 1'-0" 812712SIDINGVINYL VINYLCORNERS1'-6"8124" TRIMLPB & BLPB & B4122'-0"Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode12/13/2021dmathewsRevised 1/4/22 to add covered patio. Planco MN, Inc.C#21-084SMA282021 BASEMENT PLAN 1/4" = 1'-0" UP16 R(2) TRT. 6x6 POSTON 12x16 PIER FTG.24x24 FROST FTG. UNEXCAVATED WHFURNF.D.92%SUMP4834 FAMILY ROOM *CARPET FUT. BDRM *UNFINISHED FUT. OFFICE/STORAGE *UNFINISHED2-9 1/2" LSL2'-8"2'-6"2'-4"2-11 7/8" LSL FLUSHTREATED 4x6 CURB2x6 - 16" O.C.FTG. SIZE BY OTHERSTREATED 4x6 CURB2x6 - 16" O.C.FTG. SIZE BY OTHERSTREATED 4x4 CURB2x4 - 16" O.C.FTG. SIZE BY OTHERSTREATED 2x8 16" O.C.TRD. 3-2x8 FLUSHTRD. 3-2x8 FLUSH60'-6"15'-0"15'-0"14'-0"19'-6"8'-6"11'-0"40'-0" 4'-0"36'-0" 11'-8"7'-4"17'-0" 6'-6" 6'-0"6" 1'-0"44'-0"21'-0"8'-0"13'-0"4'-6"5'-10"9'-8"3'-8"3'-8" 14'-0"8'-0"9"9'-6"9"5'-10"10'-6"14'-10"24'-0"2" LEDGE9' POURED FOUNDATIONWALLEDGEWALLEDGE48"11 7/8" I JST. 19.2" O.C. 11 7/8" LSL 19.2" O.C. 11 7/8" LSL 19.2" O.C.2-2x10TREATED 4x4 CURB2x4 - 16" O.C.FTG. SIZE BY OTHERS20'-8" 11 7/8" I JST. 19.2" O.C.10"10'-6"5'-10"2'-2"11 7/8" I JST. 16" O.C. 18'-10"1/2 WALL2-11 7/8" LSL FLUSH42x48x12 CONC.PAD FTG. W/2-#4 REBAR EACH WAY4'-0"RADONVENTTREATED 4x6 CURB2x6 - 16" O.C.FTG. SIZE BY OTHERS”),1,6+('64)76" CANT. 3/4 R.I. SD/COGASF.P.1'-8"5'-6"6'-6"41'-0"F.D.11'-0"19'-0"11'-0"49'-0"28'-0"26'-0"2'-0" 4'-0" 12'-0"16'-6"2'-0"2'-8"2'-6"2'-6"2'-6"2'-4"7'-0"13'-0"6/0x4/0 SL 2-2x10 6'-7" 4'-3"4'-3"4'-0" UNEXCAVATED UFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. Planco MN, Inc.C#21-084SMA382021 FIRST FLOOR PLAN 1/4" = 1'-0" 1,149 SQ. FT.9' CEILING @ FIRST FLOOR60'-6"15'-0"15'-0"14'-0"PED 49'-0"REF'GUP17 RDN16 R16" S.B.3'-0"2'-6"2-9 1/2" LSL 6'-0" P.D.2'-4"2'-4"2'-4"2'-8"FIREDOORPANTRY*VINYL16" SH'S2'-8" C.O. FOYER *WOOD*WOOD DINING KITCHEN *WOOD*WOOD GREAT ROOM OFFICE *CARPET*4" CONC. FLOOR GARAGE WOOD PORCH 19'-6"41'-0"8'-6"11'-0"40'-0" 4'-0"36'-0" 11'-8"7'-4"17'-0" 6'-6" 5'-6"1'-0"1'-0"44'-0"8'-0"7'-0"7'-6"7'-6"8'-0"6'-0"21'-0"8'-0"13'-0" 6'-2"5'-10"24'-0"6'-0"8'-4"9'-8"5'-0"7'-0"*VINYL*VINYL W.I.C. *VINYL5'-3"6'-6"5'-3"2'-0"3'-6"8'-0" CAB.3'-6"7'-1"3'-6"2'-10"6'-6"3'-8"3'-8"4'-6"6'-8"10"WALLEDGEWALLEDGE2x62x6RAIL2'-6"4'-10"7'-2" 11'-0"3'-6516"GYP. BD.5'-6"4'-3"9"9'-6"9"FSD14'-0" 8'-0"CHASE30" RANGE W/ HOODVENT1'-0"5/0x5/0 SL2-2x1018" FLR.TRUSS 24" O.C. 2'-10"2'-10" 2/6x2/0 FX 2-2x10 2/6x2/0 FX 2-2x10 18" FLR.TRUSS 24" O.C. GIRDER 2-11 7/8" LSL FLUSH2-11 7/8" LSL FLUSH 24" CANT.TRUSSES 24" O.C. GIRDER F.T.2-2x1018" FLR.TRUSS 24" O.C.6'-0"2-9 1/2" LSL FLUSH2-9 1/2" LSL FLUSH2-7 1/4" LSL2-7 1/4" LSLRADONVENT*2x6 WALLSGIRDER22'-2"TRUSSES24" O.C.4'-9"2-9 1/2" LSL8/0x5/0 SL2-9 1/2" LSL5'-0"TRUSSES24" O.C.FLUSH 2'-8"GASF.P.2x61'-0"MICRO12x12 BOXEDCEDAR COLUMNREF'GRECESS3'-212"4'-2"4'-0" 28'-0"26'-0"2'-0"11'-0"19'-0"11'-0"2'-0" TRUSSES 24" O.C.F.D.16x8 OVH. DR.9x8 OVH. DR.9x8 OVH. DR.3'-0"3'-7"2-2x10SLSL5'-10"5'-2"9'-6"9'-6"5'-2"5'-10"12'-0"16'-6"2'-6"2'-6"3'x3'CONC.SLABFUT. HEATERR.I. GASGIRDER GIRDER1/31/31/32-9 1/2" LSL8/0x5/0 SL1/41/21/42-11 7/8" LSL2-11 7/8" LSL3-16" LVL3-2x103-9 1/2" LSL*COVERED CONC. PATIO TRUSSES24" O.C.HDR DROPPED 15" FROM HOUSE TRT. 6x6POSTWOOD STEPS F.P . WOOD 4'-1134"6"6'-4"4'-113 4"BWPsAboveVerify loads with girdertruss specs, may requireremoval of top plates atbearing due to crushing.INSTALL SIMPSON CS20 STRAPBETWEEN TOP PLATE OF GARAGEWALL AND BOTTOM CHORD OF FLOORTRUSS SPANNING THEKITCHEN/DINING AREA. PROVIDE AMINIMUM OF 9" OF NAILING AT EACHEND OF STRAP.10666PFHPFH895553398333(2)11-7/8 LSL Planco MN, Inc.C#21-084SMA482021 SECOND FLOOR PLAN 1/4" = 1'-0" 1,254 SQ. FT.*CARPET LOFT EXTRA OPEN *FLOORING*CARPET BEDROO BEDROO BEDROO *CARPET*CARPET*CARPET BEDROO *CARPET MASTER DN17 R5'-0" TUB & SHOWER 1 PIECE FIB.2'-6"66"2'-4"2'-6"2'-6"5'-0"2'-8"5'-0"2'-4" C.O.2'-4"39"*CARPET MASTER BEDROOM *CARPET BEDROOM #2 BEDROOM #3 *CARPET BEDROOM #4 *CARPET W.I.C. *CARPET*VINYL*VINYL5/0x6/0 FIXED 2-2x10 40" OFF LANDING TEMP 39'-0"15'-0"15'-0"9'-0"12'-10"2'-2"7'-6"7'-6"43'-0" 1'-0"38'-0"4'-0" 11'-0"2'-8"7'-4"5'-8"11'-4"WALLEDGEWALLEDGE8'-138"9'-5 5 16"3'-6"18'-0" 13'-0"5'-0"39'-0"26'-0"13'-0"12'-0"14'-0"6'-0"6'-0"7'-0"7'-0"12'-0"4'-6"5'-10"5'-11"3'-8"3'-8"8'-6"4'-6"15'-6"FF3-2x106/0x4/6 SL6'-7"6'-3"6/0x4/6 SL2-2x10SD/COSDSDSDSDACCESS ATTIC 2'-6"2'-0"2'-0"9'-5"3'-9"5' - 4 "*C.T.*C.T.GIRDERTRUSSES 24" O.C. TRUSSES 24" O.C. TRUSSES 24" O.C.TRUSSES24" O.C.GIRDERTRUSSES24" O.C.6'-5"2x62x6RADONVENT5'-0"11'-2"2'-10"3'-11"5'-10"GIRDERGIRDER 2'-6"4'-3"4'-25 16"TRUSSES24" O.C.3'-8"3'-8"2-2x102/6x4/0 SH6'-8"2'-4"24"WD11'-3 5 16"1/2 WALLW/ WD. CAP7'-1" 7'-9" 6'-8"39"2'-4"PKT.6/0x4/6 SL2-2x106'-8"5'-10"2'-6"SH'S2'-4"6'-4"5'-8"FPKT.46682'-4" 4'-0"1'-8" 2-2x10 2/0x2/0 FX *C.T.42" TALL LIN.W/ WD. TOP2-2x108/0x5/0 SL1/31/31/313'-0"33333222223333322Temper-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).Verify loads with girdertruss specs, may requireremoval of top plates atbearing due to crushing. Planco MN, Inc.C#21-084SMA582021 CROSS SECTION 3/8" = 1'-0" 17 RISERS 9'-11 8"3/4" T & G FLOORCURBTREATED 4x416 RISERS  “11 7/8" I JST. @ 19.2" O.C. CURB2X6- 16" O.C.TREATED 4x63 1/2" CONC. FLOOR2X4- 16" O.C.CURB2X6- 16" O.C.TREATED 4x68'-11 8"5/8" GYP. BD.R-21 INSUL.1/2" GYP. BD.VB2x6- 16" O.C.2x6R-21 INSUL.1/2" GYP. BD.VB2x6- 16" O.C.R-49 INSUL.11'-8"2x6- 16" O.C.1/2" GYP. BD.R-21 INSUL.1/2" GYP. BD.2x6- 16" O.C.3/4" T & G FLOOR2x42x6VBR-21 INSUL.W/ V.B.5/8" GYP. BD.VB2'-0"1'-0"R-20 SPRAY FOAM18" FLOOR TRUSSES @ 24" O.C.PER CODEWALL W/ REBAR9'-0" POUREDSILL PLATE1-2x6 TREATEDDRAIN TILE R-20 SPRAY FOAMR-20 SPRAY FOAMENERGY HEELENERGY HEEL6'-6"(DESIGNED BY MFR)TRUSSES @ 24" O.C.DECKING2x8 JTS. @ 16" O.C.6x6 POST35'-0"3'-0"GIRDERR-20 SPRAY FOAM2-7 1/4" LSL1261'-4"6'-0"5916"50% ROOF 50% SOFFITROOF VENTS @ 1/300 ATTIC1/2" SHTG.15# FELTSHINGLES1'-9"712R-30 INSUL.MIN.PROOFINGWATERR-10 W/ <2.6 ACHINSUL.24x24 PADFOOTING12x16 PIERFOOTING3-2x8GRADEVENTEDSOFFITFASCIAALUM. ALUM.TRT. 6x6 POSTSIDINGSHEATHING7/16" OSBHOUSE WRAP12x12 BOXEDCEDAR COL.4" BOXEDCEDAR BEAMFOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECSDRAIN TILE 11 7/8" LSL @ 19.2" O.C. 5/8" GYP. BD.FOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECS77 16"6'-8" MIN. HDRM1x8 RISERS5/4x11 TREADS4- 2x12 STRINGERSTAIR NOTES:10" ROUGH CUT TREADSGRADE1-2x6 TREATEDSILL PLATE9'-0" POUREDWALL W/ REBARPER CODEWATER PROOFINGFOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECSR-10 W/ <2.6 ACHINSUL.71 2"R-21 INSUL.1/2" GYP. BD.VB2x6- 16" O.C.PER CODEWALL W/ REBAR9'-0" POUREDSILL PLATE1-2x6 TREATEDPROOFINGWATERR-10 W/ <2.6 ACHINSUL.DRAIN TILE R-20 SPRAY FOAMGRADEFASCIAALUM. SOFFITVENTEDALUM.ENERGY HEEL1/2" SHTG.15# FELTSHINGLES1'-6"812R-49 INSUL.5'-0"11 7/8" LSL @ 19.2" O.C. 18" FLOOR TRUSSES @ 24" O.C. CROSS SECTION 3/8" = 1'-0" MUD ROOM 2-9 1/2" LSLSIDINGSHEATHING7/16" OSBHOUSE WRAPFOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECS Planco MN, Inc.C#21-084SMA682021 CROSS SECTION 3/8" = 1'-0" 9'-11 8"3/4" T & G FLOORCURBTREATED 4x6 “11 7/8" LSL @ 19.2" O.C. 3 1/2" CONC. FLOOR2X6- 16" O.C.8'-11 8"5/8" GYP. BD.R-21 INSUL.1/2" GYP. BD.VB2x6- 16" O.C.R-21 INSUL.1/2" GYP. BD.VB2x6- 16" O.C.R-49 INSUL.2x6- 16" O.C.1/2" GYP. BD.R-21 INSUL.1/2" GYP. BD.2x6- 16" O.C.3/4" T & G FLOORVBR-21 INSUL.W/ V.B.5/8" GYP. BD.VB4'-0"1'-0"R-20 SPRAY FOAM18" FLOOR TRUSSES @ 24" O.C.PER CODEWALL W/ REBAR9'-0" POUREDSILL PLATE1-2x6 TREATEDPROOFINGWATERR-10 W/ <2.6 ACHINSUL.DRAIN TILE R-20 SPRAY FOAMR-20 SPRAY FOAMENERGY HEELENERGY HEEL(DESIGNED BY MFR)TRUSSES @ 24" O.C.7'-6"DECKING2x8 JTS. @ 16" O.C.24x24 PADFOOTING12x16 PIERFOOTING3-2x8GRADEVENTEDSOFFITFASCIAALUM. ALUM.2-7 1/4" LSL1261'-4"7'-0"6x6 POST35'-0"4'-0"GIRDER4'-0"GIRDERCURBTREATED 4x42X4- 16" O.C.5916"2-11 7/8" LSL2-11 7/8" LSLR-20 SPRAY FOAM50% ROOF 50% SOFFITROOF VENTS @ 1/300 ATTIC1/2" SHTG.15# FELTSHINGLES712R-30 INSUL.MIN.SIDINGSHEATHING7/16" OSBHOUSE WRAPSIDINGSHEATHING7/16" OSBHOUSE WRAPTRT. 6x6 POSTFOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECS11 7/8" I JST. @ 19.2" O.C. 5/8" GYP. BD.2X6- 16" O.C.DRAIN TILE GRADE1-2x6 TREATEDSILL PLATE9'-0" POUREDWALL W/ REBARPER CODEWATER PROOFINGFOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECSR-10 W/ <2.6 ACHINSUL. Planco MN, Inc.C#21-084SMA7820214" CONC. FLOOR GARAGE GRADEPOURED WALL2X6- 16" O.C.SLOPE TO DOORS CROSS SECTION 1/4" = 1'-0" 9'-118"3/4" T & G FLOOR “11 7/8" LSL @ 19.2" O.C. 3 1/2" CONC. FLOOR8'-118"5/8" GYP. BD.R-21 INSUL.1/2" GYP. BD.VB2x6- 16" O.C.R-21 INSUL.1/2" GYP. BD.VB2x6- 16" O.C.R-49 INSUL.2x6- 16" O.C.1/2" GYP. BD.R-21 INSUL.1/2" GYP. BD.2x6- 16" O.C.3/4" T & G FLOORVBR-21 INSUL.W/ V.B.5/8" GYP. BD.VBR-20 SPRAY FOAMR-20 SPRAY FOAM18" FLOOR TRUSSES @ 24" O.C.PER CODEWALL W/ REBAR9'-0" POUREDSILL PLATE1-2x6 TREATEDPROOFINGWATERR-10 W/ <2.6 ACHINSUL.DRAIN TILE R-20 SPRAY FOAMR-20 SPRAY FOAM1/2" SHTG.15# FELTSHINGLES(DESIGNED BY MFR)TRUSSES @ 24" O.C.10'-31 4"(DESIGNED BY MFR)TRUSSES @ 24" O.C.12'-0"22'-0"4'-0"ENERGY HEEL50% ROOF 50% SOFFITROOF VENTS @ 1/300 ATTICVENTEDSOFFITALUM.ALUM. FASCIA1/2" SHTG.15# FELTSHINGLES1'-9"7128'-101116"1/2" GYP. BD.SIDINGSHEATHING7/16" OSBHOUSE WRAPSIDINGSHEATHING7/16" OSBHOUSE WRAPDRAIN TILE GRADE1-2x6 TREATEDSILL PLATE9'-0" POUREDWALL W/ REBARPER CODEWATER PROOFINGFOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECSR-10 W/ <2.6 ACHINSUL.FOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECS GARAGE 9'-11 8"3/4" T & G FLOOR CROSS SECTION 1/4" = 1'-0"  “11 7/8" LSL @ 19.2" O.C. 3 1/2" CONC. FLOORPROOFINGWATER5/8" GYP. BD.R-21 INSUL.1/2" GYP. BD.VB2x6- 16" O.C.PER CODEWALL W/ REBAR9'-0" POUREDSILL PLATE1-2x6 TREATED4" CONC. FLOORSLOPE TO DRAIN1/2" GYP. BD.R-10 W/ <2.6 ACHINSUL.18" FLOOR TRUSSES @ 24" O.C.R-20 SPRAY FOAM812(DESIGNED BY MFR)TRUSSES @ 24" O.C.GIRDER6'-0"5/8" GYP. BD.R-20 SPRAY FOAM22'-2"R-30 INSUL.MIN.R-21 INSUL.1/2" GYP. BD.VB2x6- 16" O.C.CLEATFOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECSDRAIN TILE GIRDER15'-0" ROOF PLAN 1/8" = 1'-0" 1'-9"1'-0"1'-0"1'-4"1'-9"1271271278128128128126/12GIRDERGIRDERGIRDER 1'-0"1'-6"812127GIRDERGIRDER 1'-6"4/121271278128121'-0"1'-9"1'-6"2'-0"124 Planco MN, Inc.C#21-084SMA88202118" FLOOR TRUSSES @ 24" O.C.SIDINGSHEATHING7/16" OSBHOUSE WRAPDRAIN TILE GRADE1-2x6 TREATEDSILL PLATE9'-0" POUREDWALL W/ REBARPER CODEWATER PROOFINGFOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECSR-10 W/ <2.6 ACHINSUL.8'-4" POUREDWALL W/ REBARPER CODEFOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECS4" CONC. PATIOALUM.ALUM. FASCIASOFFITVENTEDTRUSSES @ 24" O.C.(DESIGNED BY MFR)1/2" SHTG.15# FELTSHINGLES4122'-0"31116"HDRTRT. 6x6 POST13'-0"11 7/8" LSL @ 19.2" O.C. CROSS SECTION 3/8" = 1'-0" FLOOR SYSTEMROOFTRUSSPVC T-FITTINGTO SUPPORTVENT PIPEMIN. 4" OF GASPERMEABLE MATERIAL3 1/2" CONC. SLAB4" PVC VENT PIPESUPPORTSTRAPPINGFLASHINGEXHAUST 10' FROM OPNGS.INTO CONDITIONED SPACESOF BUILDING12" MIN. ABOVE ROOFSEAL6 MIL POLYUNDER SLAB10' OF DRAIN TILEEACH WAY FROMT-FITTING(ROCK) RADON GAS VENT SYSTEM 3/8" = 1'-0" 36" MIN. HT. CLEAR SPACE24" DIA. AROUND VENTPROVIDE ELECTRICALBOX POWER SOURCER-4 MIN. INSUL. VENT PIPE@ UNCONDITIONED SPACE4" MIN. CLEARANCEFOR FUT. FAN FIRST FLOOR PLAN 1,149 SQ. FT.9' CEILING @ FIRST FLOOR60'-6"15'-0"15'-0"14'-0"PED 49'-0"REF'GUP17 RDN16 R16" S.B.3'-0"2'-6"2-9 1/2" LSL 6'-0" P.D.2'-4"2'-4"2'-4"2'-8"FIREDOORPANTRY*VINYL16" SH'S2'-8" C.O. FOYER *WOOD*WOOD DINING KITCHEN *WOOD*WOOD GREAT ROOM OFFICE *CARPET*4" CONC. FLOOR GARAGE WOOD PORCH 19'-6"41'-0"8'-6"11'-0"40'-0" 4'-0"36'-0" 11'-8"7'-4"17'-0" 6'-6" 5'-6"1'-0"1'-0"44'-0"8'-0"7'-0"7'-6"7'-6"8'-0"6'-0"21'-0"8'-0"13'-0" 6'-2"5'-10"24'-0"6'-0"8'-4"9'-8"5'-0"7'-0"*VINYL*VINYL W.I.C. *VINYL5'-3"6'-6"5'-3"2'-0"3'-6"8'-0" CAB.3'-6"7'-1"3'-6"2'-10"6'-6"3'-8"3'-8"4'-6"6'-8"10"WALLEDGEWALLEDGE2x62x6RAIL2'-6"4'-10"7'-2" 11'-0"3'-6516"GYP. BD.5'-6"4'-3"9"9'-6"9"FSD14'-0" 8'-0"CHASE30" RANGE W/ HOODVENT1'-0"5/0x5/0 SL2-2x1016" FLR.TRUSS 19.2" O.C. 2'-10"2'-10" 2/6x2/0 FX 2-2x10 2/6x2/0 FX 2-2x10 16" FLR.TRUSS 19.2" O.C. GIRDER 2-11 7/8" LSL FLUSH2-11 7/8" LSL FLUSH 24" CANT.TRUSSES 24" O.C. GIRDER F.T.2-2x1016" FLR.TRUSS 19.2" O.C.6'-0"2-9 1/2" LSL FLUSH2-9 1/2" LSL FLUSH2-7 1/4" LSL2-7 1/4" LSLRADONVENT*2x6 WALLSGIRDER22'-2"TRUSSES24" O.C.4'-9"3-2x108/0x5/0 SL2-9 1/2" LSL5'-0"TRUSSES24" O.C.FLUSH 2'-8"GASF.P.2x61'-0"MICRO12x12 BOXEDCEDAR COLUMNREF'GRECESS3'-212"4'-2"4'-0" 28'-0"26'-0"2'-0"11'-0"19'-0"11'-0"2'-0" TRUSSES24" O.C.F.D.16x8 OVH. DR.9x8 OVH. DR.9x8 OVH. DR.3'-0"3'-7"2-2x10SLSL5'-10"5'-2"9'-6"9'-6"5'-2"5'-10"12'-0"16'-6"2'-6"2'-6"DECKLEDGER3'x3'CONC.SLABFUT. HEATERR.I. GASGIRDER GIRDER1/31/31/33-2x108/0x5/0 SL1/41/21/460'BWL 1BWL 2BWL 3BWL 421'21'BWL 5BWL 63'3'3'4'3'3'SEE DETAIL 1/PF-16'6'6'8'9'10'5'5'5'8'9'INSTALL SIMPSON CS20 STRAPBETWEEN TOP PLATE OF GARAGEWALL AND BOTTOM CHORD OF FLOORTRUSS SPANNING THEKITCHEN/DINING AREA. PROVIDE AMINIMUM OF 9" OF NAILING AT EACHEND OF STRAP. SECOND FLOOR PLAN 1,254 SQ. FT.DN17 R5'-0" TUB & SHOWER 1 PIECE FIB.2'-6"66"2'-4"2'-6"2'-6"5'-0"2'-8"5'-0"2'-4" C.O.2'-4"39"*CARPET MASTER BEDROOM *CARPET BEDROOM #2 BEDROOM #3 *CARPET BEDROOM #4 *CARPET W.I.C. *CARPET*VINYL*VINYL5/0x6/0 FIXED 2-2x10 40" OFF LANDING TEMP 39'-0"15'-0"15'-0"9'-0"12'-10"2'-2"7'-6"7'-6"43'-0" 1'-0"38'-0"4'-0" 11'-0"2'-8"7'-4"5'-8"11'-4"WALLEDGEWALLEDGE8'-138"9'-5 5 16"3'-6"18'-0" 13'-0"5'-0"39'-0"26'-0"13'-0"12'-0"14'-0"6'-0"6'-0"7'-0"7'-0"12'-0"4'-6"5'-10"5'-11"3'-8"3'-8"8'-6"4'-6"15'-6"FF3-2x106/0x4/6 SL6'-7"6'-3"6/0x4/6 SL2-2x10SD/COSDSDSDSDACCESS ATTIC 2'-6"2'-0"2'-0"9'-5"3'-9"5' - 4 "*C.T.*C.T.GIRDERTRUSSES 24" O.C. TRUSSES 24" O.C. TRUSSES 24" O.C.TRUSSES24" O.C.GIRDERTRUSSES24" O.C.6'-5"2x62x6RADONVENT5'-0"11'-2"2'-10"3'-11"5'-10"GIRDERGIRDER 2'-6"4'-3"4'-2 5 16"TRUSSES24" O.C.3'-8"3'-8"2-2x102/6x4/0 SH6'-8"2'-4"24"WD11'-35 16"1/2 WALLW/ WD. CAP7'-1" 7'-9" 6'-8"39"2'-4"PKT.6/0x4/6 SL2-2x106'-8"5'-10"2'-6"SH'S2'-4"6'-4"5'-8"FPKT.46682'-4" 4'-0"1'-8" 2-2x10 2/0x2/0 FX *C.T.42" TALL LIN.W/ WD. TOP3-2x108/0x5/0 SL1/31/31/3BWL 7BWL 8BWL 9BWL 10BWL 1110'29'40'2'2'3'2'2'2'2'2'3'3'3'3'3'3'3'3'3' Voigt & Associates, Inc.C-1Structural Engineering Services 4635 Nicols Road, Suite 204Eagan, MN 55122MethodCS-WSPWind speed 115Exposure CGB GB BWL 1 2 3 4 5 6 7 8 9 10 11Spacing - ft 21 21 21 30 30 30 40 40 10 29 29Level 2 2 2 2 2 2 1 1 1 1 1Length req'd- ft 6.8 13.1 6.8 9 9 9 6 6 2 4.4 4.4per Table R602.10.3(1)Adjustments:Exposure 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3Eave to ridge Height 1.12 1.12 1.12 1.12 1.12 1.12 1.24 1.24 1.24 1.24 1.24Wall Height 0.95 0.95 0.95 0.95 0.95 0.95 0.9 0.9 0.9 0.9 0.9# of BWL 1.3 1.3 1.3 1.3 1.3 1.3 1 1 1.3 1.3 1.34" Gyp WB w.block joints1 1 1 1 1 1 1 1 1 1 1Adjusted Length 12.2 23.6 12.2 16.2 16.2 16.2 8.7 8.7 3.8 8.38.3Zach & Claire Anderson Residence19814 Henning Ave, Lakeville, MN Sheet Stone Cottage HVAC Load Calculations for Stone Cottage 19814 Henning Ave Lakeville,mn Prepared By: Randy Andrews Lofgren Heating 5708 Upper 147th Street West Apple Vallley, MN 55124 Thursday, November 11, 2021 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 2 Project Report General Project Information Project Title:Stone Cottage Project Date:Thursday, November 11, 2021 Client Name:Stone Cottage Client Address:19814 Henning Ave Client City:Lakeville,mn Company Name:Lofgren Heating Company Representative:Randy Andrews Company Address:5708 Upper 147th Street West Company City:Apple Vallley, MN 55124 Company E-Mail Address:rrandrews@lofgrenheating-ac.com Design Data Reference City:Minneapolis, Minnesota Building Orientation:Front door faces West Daily Temperature Range:Medium Latitude:44 Degrees Elevation:834 ft. Altitude Factor:0.970 Elevation Sensible Adj. Factor:1.000 Elevation Total Adj. Factor:1.000 Elevation Heating Adj. Factor:1.000 Elevation Heating Adj. Factor:1.000 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter:-15 -15.33 80%n/a 72 n/a Summer:88 72 47%50%75 29 Check Figures Total Building Supply CFM:1,243 CFM Per Square ft.:0.350 Square ft. of Room Area:3,552 Square ft. Per Ton:1,275 Volume (ft³) of Cond. Space:31,968 Building Loads Total Heating Required Including Ventilation Air:52,919 Btuh 52.919 MBH Total Sensible Gain:26,872 Btuh 80 % Total Latent Gain:6,557 Btuh 20 % Total Cooling Required Including Ventilation Air:33,429 Btuh 2.79 Tons (Based On Sensible + Latent) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\19814 HENNING LAKEVILLE 11112021.rhv Thursday, November 11, 2021, 11:01 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 3 Miscellaneous Report System 1 Whole House Input Data Outdoor Dry Bulb Outdoor Wet Bulb Outdoor Rel.Hum Indoor Rel.Hum Indoor Dry Bulb Grains Difference Winter:-15 -15.33 80%n/a 72 n/a Summer:88 72 47%50%75 29.27 Duct Sizing Inputs Main Trunk Runouts Calculate:Yes Yes Use Schedule:No No Roughness Factor:0.00300 0.01000 Pressure Drop:0.1000 in.wg./100 ft.0.1000 in.wg./100 ft. Minimum Velocity:650 ft./min 450 ft./min Maximum Velocity:900 ft./min 750 ft./min Minimum Height:8 in.6 in. Maximum Height:10 in.6 in. Outside Air Data Winter Summer Infiltration Specified:0.250 AC/hr 0.130 AC/hr 90 CFM 47 CFM Infiltration Actual:0.250 AC/hr 0.130 AC/hr Above Grade Volume:Cu.ft.Cu.ft.X 21,627 X 21,627 5,407 Cu.ft./hr 2,812 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration:90 CFM 47 CFM Total Building Ventilation:140 CFM 70 CFM ---System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 13.87 = (1.10 X 0.970 X 13.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 19.31 = (0.68 X 0.970 X 29.27 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 92.85 = (1.10 X 0.970 X 87.00 Winter Temp. Difference) Winter Infiltration Specified:0.250 AC/hr (90 CFM), Construction: Unknown Summer Infiltration Specified:0.130 AC/hr (47 CFM), Construction: Unknown C:\ ...\19814 HENNING LAKEVILLE 11112021.rhv Thursday, November 11, 2021, 11:01 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 4 Load Preview Report Scope Has AED Net Ton ft.² /Ton Area Sen Gain Lat Gain Net Gain Sen Loss Sys Htg CFM Sys Clg CFM Sys Act CFM Duct Size Building 2.79 1,275 3,552 26,872 6,557 33,429 52,919 1,007 1,243 1,243 System 1 Yes 2.79 1,275 3,552 26,872 6,557 33,429 52,919 1,007 1,243 1,243 21x10 Ventilation 340 1,352 1,692 4,550 Zone 1 3,552 26,532 5,205 31,737 48,369 1,007 1,243 1,243 21x10 1-Main Level 1,149 10,594 1,858 12,452 18,262 380 496 496 6--6 2-Upper Level 1,254 14,478 2,447 16,925 21,162 441 678 678 8--6 3-Lower Level 1,149 1,460 900 2,360 8,945 186 68 68 1--6 C:\ ...\19814 HENNING LAKEVILLE 11112021.rhv Thursday, November 11, 2021, 11:01 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 5 Duct Size Preview Room or Duct Name Minimum Velocity Maximum Velocity Rough. Factor Design L/100 Actual L/100 SP Loss Duct Velocity Duct Length Htg Flow Clg Flow Act. Flow Duct Size System 1 Supply Runouts Zone 1 1-Main Level 450 750 0 0.1 0.1 421.3 380 496 496 6--6 2-Upper Level 450 750 0 0.1 0.1 431.8 441 678 678 8--6 3-Lower Level 450 750 0 0.1 0.1 348.4 186 68 68 1--6 Other Ducts Supply Main Trunk 650 900 0 0.1 0.1 852.3 1,007 1,243 1,243 21x10 SummarySummarySummarySummarySummarySummarySummarySummary System 1 Heating Flow:1007 Cooling Flow:1243 C:\ ...\19814 HENNING LAKEVILLE 11112021.rhv Thursday, November 11, 2021, 11:01 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 6 System 1 - Whole House - Adequate Exposure Diversity Test Test For Adequate Exposure Diversity Average Glass Sensible Gain Over 12 Hours 1.3 x Average Glass Gain Hourly Glass Gain Hourly Total Net GainHeat Gain, Btuh14.5% Diff. from Avg. 0 10,000 20,000 30,000 40,000 8 am 9 am 10 am 11 am 12 pm 1 pm 2 pm 3 pm 4 pm 5 pm 6 pm 7 pm AED Calculation Summary --- SYSTEM HAS ADEQUATE EXPOSURE DIVERSITY. --- System is on N, E, S, W rosette. Peak load exceeds 12-hour average load by 14.5%. AED Excursion (amount by which peak exceeds 1.3 x average): 0 Btuh Definition: A system has adequate exposure diversity if the peak-hour glass load for the entire conditioned space does not exceed the average glass load for the entire conditioned space by more than 30 percent. C:\ ...\19814 HENNING LAKEVILLE 11112021.rhv Thursday, November 11, 2021, 11:01 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 7 System 1 - Whole House - Psychrometric Chart ZC Zone (Room) Condition OC Outdoor Condition LC Leaving Coil Condition EC Entering Coil Condition SD Supply Duct Temperature Rise DTF Draw Through Fan Sensible Gain HRV Heat Recovery Ventilator C:\ ...\19814 HENNING LAKEVILLE 11112021.rhv Thursday, November 11, 2021, 11:01 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 8 Total Building Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain 4A-1a-o: Glazing-Double pane low-e (e = 0.20 or less), operable window, e=0.20 on surface 2, wood with metal clad frame, u-value 0.32, SHGC 0.33 493 13,725 0 13,135 13,135 11N: Door-Metal - Polystyrene Core 42 1,278 0 352 352 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs 2453 13,872 0 2,121 2,121 15B0-10sf-10: Wall-Basement, , R-10 board insulation to floor, no interior finish, 10' floor depth 1512 6,446 0 0 0 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation 1254 2,182 0 1,204 1,204 21A-24: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 24' wide 1149 2,499 0 0 0 Subtotals for structure:40,002 0 16,812 16,812 People:9 1,800 2,070 3,870 Equipment:2,500 7,000 9,500 Lighting:0 0 0 Ductwork:0 0 0 0 Infiltration: Winter CFM: 90, Summer CFM: 47 8,367 905 650 1,555 Ventilation: Winter CFM: 140, Summer CFM: 70 4,550 1,352 340 1,692 Total Building Load Totals:52,919 6,557 26,872 33,429 Check Figures Total Building Supply CFM:1,243 CFM Per Square ft.:0.350 Square ft. of Room Area:3,552 Square ft. Per Ton:1,275 Volume (ft³) of Cond. Space:31,968 Building Loads Total Heating Required Including Ventilation Air:52,919 Btuh 52.919 MBH Total Sensible Gain:26,872 Btuh 80 % Total Latent Gain:6,557 Btuh 20 % Total Cooling Required Including Ventilation Air:33,429 Btuh 2.79 Tons (Based On Sensible + Latent) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\19814 HENNING LAKEVILLE 11112021.rhv Thursday, November 11, 2021, 11:01 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 9 Building Pie Chart Building Loss 52,919 Btuh Floor 5%Roof 4% Wall 38% Glass 26% Door 2% Infiltration 16% Ventilation 9% Building Gain 33,429 Btuh Roof 4%Wall 6% Glass 39% Door 1%People 12% Equipment 28% Infiltration 5%Ventilation 5% C:\ ...\19814 HENNING LAKEVILLE 11112021.rhv Thursday, November 11, 2021, 11:01 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 10 Building Bar Graph Building Loss 52,919 Btuh 0 5,000 10,000 15,000 20,000 25,000 Floor 5%Wall 38%Door 2%Ventilation 9% Roof 4%Glass 26%Infiltration 16% Building Gain 33,429 Btuh 0 5,000 10,000 15,000 Roof 4%Glass 39%People 12%Infiltration 5% Wall 6%Door 1%Equipment 28%Ventilation 5% C:\ ...\19814 HENNING LAKEVILLE 11112021.rhv Thursday, November 11, 2021, 11:01 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 11 System 1 Whole House Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain 4A-1a-o: Glazing-Double pane low-e (e = 0.20 or less), operable window, e=0.20 on surface 2, wood with metal clad frame, u-value 0.32, SHGC 0.33 493 13,725 0 13,135 13,135 11N: Door-Metal - Polystyrene Core 42 1,278 0 352 352 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs 2453 13,872 0 2,121 2,121 15B0-10sf-10: Wall-Basement, , R-10 board insulation to floor, no interior finish, 10' floor depth 1512 6,446 0 0 0 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation 1254 2,182 0 1,204 1,204 21A-24: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 24' wide 1149 2,499 0 0 0 Subtotals for structure:40,002 0 16,812 16,812 People:9 1,800 2,070 3,870 Equipment:2,500 7,000 9,500 Lighting:0 0 0 Ductwork:0 0 0 0 Infiltration: Winter CFM: 90, Summer CFM: 47 8,367 905 650 1,555 Ventilation: Winter CFM: 140, Summer CFM: 70 4,550 1,352 340 1,692 System 1 Whole House Load Totals:52,919 6,557 26,872 33,429 Check Figures Supply CFM:1,243 CFM Per Square ft.:0.350 Square ft. of Room Area:3,552 Square ft. Per Ton:1,275 Volume (ft³) of Cond. Space:31,968 System Loads Total Heating Required Including Ventilation Air:52,919 Btuh 52.919 MBH Total Sensible Gain:26,872 Btuh 80 % Total Latent Gain:6,557 Btuh 20 % Total Cooling Required Including Ventilation Air:33,429 Btuh 2.79 Tons (Based On Sensible + Latent) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\19814 HENNING LAKEVILLE 11112021.rhv Thursday, November 11, 2021, 11:01 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 12 System 1 Whole House Pie Chart System 1 Whole House Loss 52,919 Btuh Floor 5%Roof 4% Wall 38% Glass 26% Door 2% Infiltration 16% Ventilation 9% System 1 Whole House Gain 33,429 Btuh Roof 4%Wall 6% Glass 39% Door 1%People 12% Equipment 28% Infiltration 5%Ventilation 5% C:\ ...\19814 HENNING LAKEVILLE 11112021.rhv Thursday, November 11, 2021, 11:01 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 13 System 1 Whole House Bar Graph System 1 Whole House Loss 52,919 Btuh 0 5,000 10,000 15,000 20,000 25,000 Floor 5%Wall 38%Door 2%Ventilation 9% Roof 4%Glass 26%Infiltration 16% System 1 Whole House Gain 33,429 Btuh 0 5,000 10,000 15,000 Roof 4%Glass 39%People 12%Infiltration 5% Wall 6%Door 1%Equipment 28%Ventilation 5% C:\ ...\19814 HENNING LAKEVILLE 11112021.rhv Thursday, November 11, 2021, 11:01 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 14 System 1, Zone 1 Summary Loads (Average Load Procedure for Rooms) Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain 4A-1a-o: Glazing-Double pane low-e (e = 0.20 or less), operable window, e=0.20 on surface 2, wood with metal clad frame, u-value 0.32, SHGC 0.33 493 13,725 0 13,135 13,135 11N: Door-Metal - Polystyrene Core 42 1,278 0 352 352 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs 2453 13,872 0 2,121 2,121 15B0-10sf-10: Wall-Basement, , R-10 board insulation to floor, no interior finish, 10' floor depth 1512 6,446 0 0 0 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation 1254 2,182 0 1,204 1,204 21A-24: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 24' wide 1149 2,499 0 0 0 Subtotals for structure:40,002 0 16,812 16,812 People:9 1,800 2,070 3,870 Equipment:2,500 7,000 9,500 Lighting:0 0 0 Ductwork:0 0 0 0 Infiltration: Winter CFM: 90, Summer CFM: 47 8,367 905 650 1,555 System 1, Zone 1 Load Totals:48,369 5,205 26,532 31,737 Check Figures Supply CFM:1,243 CFM Per Square ft.:0.350 Square ft. of Room Area:3,552 Square ft. Per Ton:1,343 Volume (ft³) of Cond. Space:31,968 Zone Loads Total Heating Required:48,369 Btuh 48.369 MBH Total Sensible Gain:26,532 Btuh 84 % Total Latent Gain:5,205 Btuh 16 % Total Cooling Required:31,737 Btuh 2.64 Tons (Based On Sensible + Latent) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\19814 HENNING LAKEVILLE 11112021.rhv Thursday, November 11, 2021, 11:01 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 15 System 1, Zone 1 Pie Chart System 1, Zone 1 Loss 48,369 Btuh Floor 5%Roof 5% Wall 42% Glass 28% Door 3% Infiltration 17% System 1, Zone 1 Gain 31,737 Btuh Roof 4%Wall 7% Glass 41% Door 1% People 12% Equipment 30% Infiltration 5% C:\ ...\19814 HENNING LAKEVILLE 11112021.rhv Thursday, November 11, 2021, 11:01 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 16 System 1, Zone 1 Bar Graph System 1, Zone 1 Loss 48,369 Btuh 0 5,000 10,000 15,000 20,000 25,000 Floor 5%Wall 42%Door 3% Roof 5%Glass 28%Infiltration 17% System 1, Zone 1 Gain 31,737 Btuh 0 5,000 10,000 15,000 Roof 4%Glass 41%People 12%Infiltration 5% Wall 7%Door 1%Equipment 30% C:\ ...\19814 HENNING LAKEVILLE 11112021.rhv Thursday, November 11, 2021, 11:01 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 17 Detailed Room Loads - Room 1 - Main Level (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:1,149.0 ft.System Number:1 Room Width:1.0 ft.Zone Number:1 Area:1,149.0 sq.ft.Supply Air:496 CFM Ceiling Height:9.0 ft.Supply Air Changes:2.9 AC/hr Volume:10,341.0 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:6 Actual Winter Vent.:53 CFM Runout Air:83 CFM Percent of Supply.:11 % Runout Duct Size:6 in.Actual Summer Vent.:28 CFM Runout Air Velocity:421 ft./min.Percent of Supply:6 % Runout Air Velocity:421 ft./min.Actual Winter Infil.:46 CFM Actual Loss:0.111 in.wg./100 ft.Actual Summer Infil.:24 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain E -Wall-12F-0sw 44 X 9 316 0.065 5.7 1,787 0.9 0 273 W -Wall-12F-0sw 44 X 9 313 0.065 5.7 1,770 0.9 0 271 N -Wall-12F-0sw 40 X 9 315 0.065 5.7 1,781 0.9 0 272 S -Wall-12F-0sw 40 X 9 326 0.065 5.7 1,844 0.9 0 282 W -Door-11N 3 X 7 21 0.350 30.5 639 8.4 0 176 W -Door-11N 3 X 7 21 0.350 30.5 639 8.4 0 176 E -Gls-4A-1a-o shgc-0.33 0%S 80 0.320 27.8 2,227 35.0 0 2,800 W -Gls-4A-1a-o shgc-0.33 0%S 41 0.320 27.8 1,141 35.0 0 1,435 N -Gls-4A-1a-o shgc-0.33 100%S 45 0.320 27.8 1,253 10.4 0 468 S -Gls-4A-1a-o shgc-0.33 0%S 34 0.320 27.8 947 19.2 0 652 Subtotals for Structure:14,028 0 6,805 Infil.: Win.: 45.6, Sum.: 23.7 1,512 2.800 4,234 0.218 458 329 People: 200 lat/per, 230 sen/per:2 400 460 Equipment:1,000 3,000 Room Totals:18,262 1,858 10,594 C:\ ...\19814 HENNING LAKEVILLE 11112021.rhv Thursday, November 11, 2021, 11:01 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 18 Detailed Room Loads - Room 2 - Upper Level (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:1,254.0 ft.System Number:1 Room Width:1.0 ft.Zone Number:1 Area:1,254.0 sq.ft.Supply Air:678 CFM Ceiling Height:9.0 ft.Supply Air Changes:3.6 AC/hr Volume:11,286.0 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:8 Actual Winter Vent.:61 CFM Runout Air:85 CFM Percent of Supply.:9 % Runout Duct Size:6 in.Actual Summer Vent.:38 CFM Runout Air Velocity:432 ft./min.Percent of Supply:6 % Runout Air Velocity:432 ft./min.Actual Winter Infil.:45 CFM Actual Loss:0.117 in.wg./100 ft.Actual Summer Infil.:23 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain E -Wall-12F-0sw 39 X 9 254 0.065 5.7 1,436 0.9 0 220 W -Wall-12F-0sw 39 X 9 276 0.065 5.7 1,561 0.9 0 239 N -Wall-12F-0sw 43 X 9 323 0.065 5.7 1,827 0.9 0 279 S -Wall-12F-0sw 43 X 9 330 0.065 5.7 1,866 0.9 0 285 E -Gls-4A-1a-o shgc-0.33 0%S 97 0.320 27.8 2,700 35.0 0 3,396 W -Gls-4A-1a-o shgc-0.33 0%S 75 0.320 27.8 2,088 35.0 0 2,625 N -Gls-4A-1a-o shgc-0.33 100%S 64 0.320 27.8 1,782 10.4 0 666 S -Gls-4A-1a-o shgc-0.33 0%S 57 0.320 27.8 1,587 19.2 0 1,093 UP-Ceil-16B-50 1254 X 1 1254 0.020 1.7 2,182 1.0 0 1,204 Subtotals for Structure:17,029 0 10,007 Infil.: Win.: 44.5, Sum.: 23.1 1,476 2.800 4,133 0.217 447 321 People: 200 lat/per, 230 sen/per:5 1,000 1,150 Equipment:1,000 3,000 Room Totals:21,162 2,447 14,478 C:\ ...\19814 HENNING LAKEVILLE 11112021.rhv Thursday, November 11, 2021, 11:01 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 19 Detailed Room Loads - Room 3 - Lower Level (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:1,149.0 ft.System Number:1 Room Width:1.0 ft.Zone Number:1 Area:1,149.0 sq.ft.Supply Air:68 CFM Ceiling Height:9.0 ft.Supply Air Changes:0.4 AC/hr Volume:10,341.0 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:1 Actual Winter Vent.:26 CFM Runout Air:68 CFM Percent of Supply.:38 % Runout Duct Size:6 in.Actual Summer Vent.:4 CFM Runout Air Velocity:348 ft./min.Percent of Supply:6 % Runout Air Velocity:348 ft./min.Actual Winter Infil.:0 CFM Actual Loss:0.077 in.wg./100 ft.Actual Summer Infil.:0 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain E -Wall-15B0-10sf-10 44 X 9 396 0.049 4.3 1,688 0.0 0 0 W -Wall-15B0-10sf-10 44 X 9 396 0.049 4.3 1,688 0.0 0 0 N -Wall-15B0-10sf-10 40 X 9 360 0.049 4.3 1,535 0.0 0 0 S -Wall-15B0-10sf-10 40 X 9 360 0.049 4.3 1,535 0.0 0 0 Floor-21A-24 1 X 1149 1149 0.025 2.2 2,499 0.0 0 0 Subtotals for Structure:8,945 0 0 Infil.: Win.: 0.0, Sum.: 0.0 0 0 0 0 0 0 People: 200 lat/per, 230 sen/per:2 400 460 Equipment:500 1,000 Room Totals:8,945 900 1,460 C:\ ...\19814 HENNING LAKEVILLE 11112021.rhv Thursday, November 11, 2021, 11:01 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 20 Room Cooling and Heating Loads Bar Graphs Cooling Heating Btuh Lower Level Upper Level Main Level 0 5,000 10,000 15,000 20,000 25,000 C:\ ...\19814 HENNING LAKEVILLE 11112021.rhv Thursday, November 11, 2021, 11:01 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 21 Room Cooling Loads Bar Graphs Sensible Latent Btuh Lower Level Upper Level Main Level 0 5,000 10,000 15,000 20,000 C:\ ...\19814 HENNING LAKEVILLE 11112021.rhv Thursday, November 11, 2021, 11:01 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 22 System 1 Room Load Summary No Room Name Area SF Htg Sens Btuh Min Htg CFM Run Duct Size Run Duct Vel Clg Sens Btuh Clg Lat Btuh Min Clg CFM Act Sys CFM ---Zone 1--- 1 Main Level 1,149 18,262 380 6-6 421 10,594 1,858 496 496 2 Upper Level 1,254 21,162 441 8-6 432 14,478 2,447 678 678 3 Lower Level 1,149 8,945 186 1-6 348 1,460 900 68 68 Ventilation 4,550 340 1,352 System 1 total 3,552 52,919 1,007 26,872 6,557 1,243 1,243 System 1 Main Trunk Size:21x10 in. Velocity:852 ft./min Loss per 100 ft.:0.107 in.wg Cooling System Summary Cooling Tons Sensible/Latent Split Sensible Btuh Latent Btuh Total Btuh Net Required:2.79 80% / 20%26,872 6,557 33,429 Actual:1.00 77% / 23%9,240 2,760 12,000 Equipment Data Heating System Cooling System Type:Natural Gas Furnace Standard Air Conditioner Model:QC-F38-E78-G QC-C12 Indoor Model:S12 Brand:Quikcool FE Series Quikcool AS Series Description:Hi Efficiency Furnace Standard Efficiency Air Condit Efficiency:78.3 AFUE 12.4 SEER Sound:8.1 bels Capacity:38,000 Btuh 12,000 Btuh Sensible Capacity:n/a 9,240 Btuh Latent Capacity:n/a 2,760 Btuh C:\ ...\19814 HENNING LAKEVILLE 11112021.rhv Thursday, November 11, 2021, 11:01 AM Builders Associaton of Minnesota version 101014 Date Certificate Posted x Passive (No Fan) Active (With fan and monometer or other system monitoring Location (or future location) of Fan: Other Please Describe Here x 10/15 x x x 20 x 20 x 21 x 49 x x x x x Not applicable, all ducts located in conditioned space x Not required per mech. code Passive Powered Interlocked with exhaust device. Describe:Input in BTUS: 70,000 Capacity in Gallons: Other, describe: AFUE or HSPF% 93% Cfm's " round duct OR " metal duct Not required per mech. code x Passive Low: Other, describe: x Low: Location of fan(s), describe: Cfm's 4" " round duct OR Flex " metal duct City Mailing Address of the Dwelling or Dwelling Unit Combustion Air Select a Type Location of duct or system: 33,429 Below Entire Slab Rigid, Extruded Polystyrene Ceiling, flat Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. Place your logo here New Construction Energy Code Compliance Certificate Name of Residential Contractor Stone Cottage Construction Inc. MN License Number Lakeville19814 Henning Ave BC636874 Mech Room Heat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: 52,919 Heating Gain Cooling Load Attic Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area Rim Joist (2nd Floor+) 0.30 Appliances THERMAL ENVELOPE Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM Non or Not Applicable Cooling SystemTotal R-Value of all Types of InsulationType: Check All That Apply Mineral Fiberboard Insulation Location Foam, Closed Cell0.22 Describe other insulated areas Fiberglass, BlownFiberglass, Batts Foundation Wall R-value Average U-Factor (excludes skylights and one door) U: Duct system air tightness: Building envelope air tightness: Rim Joist (1st Floor) GPVL-50 13ACXN042-230 Model Heating System Natrual Gas Lennox Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Electric Make-up Air Select a Type AO Smith Domestic Water Heater MECHANICAL SYSTEMS Rating or Size Efficiency 13 Seer 200CFM Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): 26,872Residential Load Calculation SEER /EER Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Capacity continuous ventilation rate in cfms: ML193UH070 Heating Loss Manufacturer Lennox Natural Gas Output in Tons: 3 Ton50 NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. New residential building permits WILL NOT be issued without this completed form. Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ Primary Contact: _________________________________________________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Description of Land Disturbing Activity: _____________________________________________________ NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___ If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an erosion and sediment control plan MUST be submitted with the residential building permit application. “The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.” (NPDES Construction Stormwater Permit, MPCA) “The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA) Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name of Person: ________________________________Company: _______________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: ________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots. No land disturbing activity may begin until a residential building permit has been issued. I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 12/02/21 KP X