Loading...
HomeMy WebLinkAboutLA198586 - 19770 Henning Ave Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: 20195 Holyoke Avenue, Lakeville, MN 55044 952-985-4400  952-985-4499 fax www.lakevillemn.gov Sewer & Water Tie Card Address:________________________________________ Contractor:______________________________________ Permit Number:__________________________________ Final Date:________________ Street Drain-Tile:______ Size of Water Service: 1” Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME OF SEWER & WATER INSPECTION *ALL DOOR & WINDOW HEADERSTO BE S.P.F. #2 OR BETTERRESIDENCE FOR:written consent of Planco MN, Inc. modified or used in any redesign without the priormay not be assigned or copied, and may not bemay not be re-used for any additional structures,structure. Planco MN reserves all rights. These planslicense is granted to use these plans to build oneCopyright for these drawings is owned by Planco MN,Planco MN, Inc.cTRACY SMITH#21-092SMA162021STONE COTTAGE CONSTRUCTION, INC. 19770 HENNING AVE, LAKEVILLE LOT 3, BLOCK 1, BERRES RIDGE 6TH ADDITIONGRADE LINESVERIFY ALL FRONT ELEVATION 1/4" = 1'-0" 812STONECAP4" EXPOSUREVINYL SIDING4" VINYL TRIMSTONEVINYLB & BVINYLB & BWOOD PORCH9' CEILING @ FIRST FLOOR8'-4" POURED FOUNDATION16x7 OVH. DR.1'-6"STONEON JOGGLASS @ TOP PANELVINYL B & BFRONT ONLY4" EXPOSURE VINYL SIDINGALL SIDESALUM. SOFFIT & FASCIAALL SIDESWDW. GRIDS AS SHOWNFRONT ONLYSTONE AS SHOWNFRONT & LEFT SIDE71271212x12 BOXEDCOLUMN4" VINYL TRIM9x7 OVH. DR.GLASS @ TOP PANELTOTALBSM'T1st FLR.1,650 SQ. FT.662 SQ. FT.2,312 SQ. FT. LEFT ELEVATION 1/8" = 1'-0" 8121'-0"SIDINGVINYL VINYLCORNERS712 RIGHT ELEVATION 1/8" = 1'-0" 1'-9"SIDINGVINYL VINYLCORNERS712 REAR ELEVATION 1/8" = 1'-0" 1'-0"VINYLCORNERSSIDINGVINYL 14' DECKLEDGER712Secure door closed until deck isconstructed with a separate permit.Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode12/28/2021dmathews Planco MN, Inc.C#21-092SMA262021 BASEMENT PLAN 1/4" = 1'-0" 8'-4" POURED FOUNDATION10"UP 15 R UNEXCAVATED 2" LEDGE2668286828682-2x102-2x1042"24682-2x10WHFURNF.D.92%*UNFINISHED FUT. FAMILY/REC RM *UNFINISHED MECH/STORAGE *UNFINISHED STORAGE (2) TRT. 6x6 POSTON 12x16 PIER FTG.24x24 FROST FTG.56'-0"38'-0" 46'-0"22'-0"24'-0"20'-0"2'-0"56'-0"30'-0"26'-0"11'-0"19'-0"12'-0"14'-0"6'-0" 2'-6" 4'-0"2'-6"4'-0" 8'-0"2" LEDGE1'-0"27'-0"6'-6" 13'-6" 6'-6"17'-6"WALKOUT6'-2"6'-0"6'-2"14'-2"9'-2"20'-6"17'-6"3'-6"8'-6"8'-6"3'-8" I.D.7'-10"10"4'-0"4'-4" 4'-4" 9'-2"13'-10"11'-6"TREATED 2x8 16" O.C. 8'-6"TRT. 3-2x10 FLUSH11 7/8" LSL JOISTS 11 7/8" LSL JOISTS 6'-8"4'-0"266811'-8" FUT. BDRM FUT. BDRM *UNFINISHED*UNFINISHED24682-2x1012'-0"12'-0"2'-6"29'-6"5'-10"6'-0"24x24LIN.SUMP9'-6"4'-0"2x4 - 16" O.C.TRT. 4x4 CURB16x8 FTG.RADONVENT2'-0"1-11 7/8" LSLFLUSH1-11 7/8" LSLFLUSH14'-0"50689/0x5/0 SL3-9 1/2" LSL6/0x4/0 SL2-2x106/0x4/0 SL2-9 1/2" LSL2-2x1060610 P.D.6x3 CONC. SLABLOOKOUT LOOKOUT WALKOUT4834 3/4 R.I. 11 7/8" LSL JOISTS 11 7/8" LSL JOISTS 3333UFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. Planco MN, Inc.C#21-092SMA362021 FIRST FLOOR PLAN 1/4" = 1'-0" 1,650 SQ. FT.9' CEILING @ FIRST FLOOR9x7 OVH. DR.16x7 OVH. DR.306830683/0x5/6 SHTEMPTOP @ 6'-8"24683'-0"2-2x105'-0" TUB& SHOWER1 PIECE FIB.36"4'-6"4'-10"206826683068 C.O. FOYER *WOOD*4" CONC. FLOOR GARAGE *2x6 WALLS2868FIREDOOR2468246812" SH'SPANT.*WOODMICROOVEN/REF'G 36"30" COOTOPW/ HOOD3'-6"16" S.B.2'-2"2x62x2GASF.P.27'-10"13'-8"12'-0"2'-6"56'-0" WOOD PORCH 2/6x4/0 SHTOP @ 6'-8"2-2x102/6x4/0 SHTOP @ 6'-8"2-2x10*WOOD DINING KITCHEN *WOOD*WOOD GREAT ROOM *CARPET MASTER BEDROOM *CARPET OFFICE/BEDROOM #2 *CARPET W.I.C. *WOOD MUD RM *WOOD W.I.C. *VINYLF3'-6"2x6DN15 RTRUSSES 24" O.C.TRUSSES24" O.C.TRUSSES 24" O.C. TRUSSES 24" O.C. 10" 15'-6"11'-0"11'-6" 38'-0"7'-0"6'-8"6'-0"13'-10"8'-0"2-2x1060610 P.D.6/0x5/0 SL2-2x106'-2"5'-10"46'-0"22'-0"24'-0"12'-1"5'-5"6'-6"20'-0"2'-0"56'-0"30'-0"26'-0"11'-0"19'-0"12'-0"14'-0"4'-0"1'-8"4'-8"6'-6"4'-4"3'-10"3'-8" I.D.7'-0"1'-8"4'-0"3'-412"6'-0" 2'-6" 2'-0"3'-7"3'-7"5'-10"5'-2"9'-6"9'-6"4'-0"2'-6"4'-0" 8'-0" 8'-8"4'-4" 9'-8"5'-6"8'-0"4'-6"9'-0"8'-11"8'-4" 4'-4"3-7 1/4" LVL*WOODRAIL2-2x102'-6"2'-8"2-2x1012x12 BOXEDCOLUMNRADONVENT14" DECKLEDGER2-2x122-11 7/8" LSLCAB. ENDPANEL14'-4"LEGS14'-0"7/6x5/0 SL2-9 1/2" LSL3-9 1/2" LSL9/0x5/0 SL50682'-6"8'-0" CAB.18'-0"2468PKT.84" STACK W & D6'-10"F286828682468LIN.2'-0"7'-8"8'-2"5'-8"3'-4"7'-4" 3'-4"7'-8" 2-2x10 5/0x2/0 FX F32x60 FREESTANDING TUB 3648*C.T.*C.T.*C.T.Temper if within60" of tub floor.333335PFHPFH5CS-PF Planco MN, Inc.C#21-092SMA462021 CROSS SECTION 3/8" = 1'-0" SHEATHINGSIDING1-2x6 TREATEDR-21 INSUL.9'-11 8"3 1/2" CONC. FLOORR-20 SPRAY FOAM1/2" GYP. BD.VB8'-4" POURED “WALL W/ REBARPER CODE3/4" T & G FLOORSILL PLATE2x6- 16" O.C.32'-0"5/8" GYP. BD.W/ V.B.2x6- 16" O.C.VB1/2" GYP. BD.R-21 INSUL.SIDINGSHEATHING(DESIGNED BY MFR)TRUSSES @ 24" O.C.R-49 INSUL.WATERPROOFINGGRADE8'-0"8'-6"R-10 W/ <2.6 ACHINSUL.TRT. 2x8 JTS. @ 16" O.C.24x24 FROSTFOOTING12x16 PIERFOOTINGTRT. 3-2x10TRT. 6x6 POST GREAT ROOM 6'-8" MIN. HDRM1x8 RISERS5/4x11 TREADS3- 2x12 STRINGERSTAIR NOTES:10" ROUGH CUT TREADSHOUSEWRAPHOUSEWRAPTREX DECKING19'-4"12'-8"ENERGY HEELFASCIAALUM. ALUM.SOFFITVENTED1'-9"LAUNDRYWALL3-7 1/4" LVL6'-0"1-11 7/8" LSL50% ROOF 50% SOFFITROOF VENTS @ 1/300 ATTICVENTEDSOFFITALUM.ALUM. FASCIA1/2" SHTG.15# FELTSHINGLES1'-9"71212x12 BOXED COL.FOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECSDRAIN TILE FOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECSPOURED WALLGRADE2" FOAM758"2" FOAM W/“%(9(/512"4'-0"R-21 INSUL.VB2x6- 16" O.C.5/8" GYP. BD.6'-111 4"10"73 8"11 7/8" LSL JOISTS Planco MN, Inc.C#21-092SMA562021 CROSS SECTION 3/8" = 1'-0" SHEATHINGSIDING1-2x6 TREATEDR-20 SPRAY FOAMR-21 INSUL.9'-11 8"3 1/2" CONC. FLOORR-20 SPRAY FOAM1/2" GYP. BD.VB8'-4" POURED “WALL W/ REBARPER CODE3/4" T & G FLOORSILL PLATE2x6- 16" O.C.24'-0"5/8" GYP. BD.W/ V.B.2x6- 16" O.C.VB1/2" GYP. BD.R-21 INSUL.(DESIGNED BY MFR)TRUSSES @ 24" O.C.R-49 INSUL.WATERPROOFING4" CONC. FLOOR GARAGE GRADEPOURED WALL2X6- 16" O.C.24'-0"SLOPE(DESIGNED BY MFR)TRUSSES @ 24" O.C.R-10 W/ <2.6 ACHINSUL.1/2" GYP. BD. DINING HOUSEWRAPSIDINGSHEATHINGHOUSEWRAP KITCHEN ENERGY HEELTRT. 4x4 CURB2x4- 16" O.C.50% ROOF 50% SOFFITROOF VENTS @ 1/300 ATTICVENTEDSOFFITALUM.ALUM. FASCIA1/2" SHTG.15# FELTSHINGLES1'-9"712DRAIN TILE FOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECSFOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECSFOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECSPOURED WALLGRADE2" FOAM758"2" FOAM W/“%(9(/512"4'-0"11 7/8" I JTS. @ 19.2" O.C.R-21 INSUL.1/2" GYP. BD.VB2x6- 16" O.C.5/8" GYP. BD. Planco MN, Inc.C#21-092SMA662021FLOOR SYSTEMROOFTRUSSPVC T-FITTINGTO SUPPORTVENT PIPEMIN. 4" OF GASPERMEABLE MATERIAL3 1/2" CONC. SLAB4" PVC VENT PIPESUPPORTSTRAPPINGFLASHINGEXHAUST 10' FROM OPNGS.INTO CONDITIONED SPACESOF BUILDING12" MIN. ABOVE ROOFSEAL6 MIL POLYUNDER SLAB10' OF DRAIN TILEEACH WAY FROMT-FITTING(ROCK) RADON GAS VENT SYSTEM 3/8" = 1'-0" 36" MIN. HT. CLEAR SPACE24" DIA. AROUND VENTPROVIDE ELECTRICALBOX POWER SOURCER-4 MIN. INSUL. VENT PIPE@ UNCONDITIONED SPACE4" MIN. CLEARANCEFOR FUT. FAN ROOF PLAN 1/8" = 1'-0" 8128121'-0"1'-9"1'-0"1'-9"712712712 BASEMENT PLAN 8'-4" POURED FOUNDATION10"UP 15 R UNEXCAVATED 2" LEDGE2668286828682-2x102-2x1042"24682-2x10WHFURNF.D.92%*UNFINISHED FUT. FAMILY/REC RM *UNFINISHED MECH/STORAGE *UNFINISHED STORAGE (2) TRT. 6x6 POSTON 12x16 PIER FTG.24x24 FROST FTG.56'-0"38'-0" 46'-0"22'-0"24'-0"20'-0"2'-0"56'-0"30'-0"26'-0"11'-0"19'-0"12'-0"14'-0"6'-0" 2'-6" 4'-0"2'-6"4'-0" 8'-0"2" LEDGE1'-0"27'-0"6'-6" 13'-6" 6'-6"17'-6"WALKOUT6'-2"6'-0"6'-2"14'-2"9'-2"20'-6"17'-6"3'-6"8'-6"8'-6"3'-8" I.D.7'-10"10"4'-0"4'-4" 4'-4" 9'-2"13'-10"11'-6"TREATED 2x8 16" O.C. 8'-6"TRT. 3-2x10 FLUSH11 7/8" LSL JOISTS 11 7/8" LSL JOISTS 6'-8"4'-0"266811'-8" FUT. BDRM FUT. BDRM *UNFINISHED*UNFINISHED24682-2x1012'-0"12'-0"2'-6"29'-6"5'-10"6'-0"24x24LIN.SUMP9'-6"4'-0"2x4 - 16" O.C.TRT. 4x4 CURB16x8 FTG.RADONVENT2'-0"1-11 7/8" LSLFLUSH1-11 7/8" LSLFLUSH14'-0"50689/0x5/0 SL3-9 1/2" LSL6/0x4/0 SL3-2x106/0x4/0 SL2-9 1/2" LSL2-2x1060610 P.D.6x3 CONC. SLABLOOKOUT LOOKOUT WALKOUT4834 3/4 R.I. 11 7/8" LSL JOISTS 11 7/8" LSL JOISTS 10'BWL 13'3'3'3' FIRST FLOOR PLAN 1,650 SQ. FT.9' CEILING @ FIRST FLOOR9x7 OVH. DR.16x7 OVH. DR.306830683/0x5/6 SHTEMPTOP @ 6'-8"24683'-0"3-2x105'-0" TUB& SHOWER1 PIECE FIB.36"4'-6"4'-10"206826683068 C.O. FOYER *WOOD*4" CONC. FLOOR GARAGE *2x6 WALLS2868FIREDOOR2468246812" SH'SPANT.*WOODMICROOVEN/REF'G 36"30" COOTOPW/ HOOD3'-6"16" S.B.2'-2"2x62x2GASF.P.27'-10"13'-8"12'-0"2'-6"56'-0" WOOD PORCH 2/6x4/0 SHTOP @ 6'-8"2-2x102/6x4/0 SHTOP @ 6'-8"2-2x10*WOOD DINING KITCHEN *WOOD*WOOD GREAT ROOM *CARPET MASTER BEDROOM *CARPET OFFICE/BEDROOM #2 *CARPET W.I.C. *WOOD MUD RM *WOOD W.I.C. *VINYLF3'-6"2x6DN15 RTRUSSES 24" O.C.TRUSSES24" O.C.TRUSSES24" O.C. TRUSSES 24" O.C. 10" 15'-6"11'-0"11'-6" 38'-0"7'-0"6'-8"6'-0"13'-10"8'-0"2-2x1060610 P.D.6/0x5/0 SL2-9 1/2" LSL6'-2"5'-10"46'-0"22'-0"24'-0"12'-1"5'-5"6'-6"20'-0"2'-0"56'-0"30'-0"26'-0"11'-0"19'-0"12'-0"14'-0"4'-0"1'-8"4'-8"6'-6"4'-4"3'-10"3'-8" I.D.7'-0"1'-8"4'-0"3'-412"6'-0" 2'-6" 2'-0"3'-7"3'-7"5'-10"5'-2"9'-6"9'-6"4'-0"2'-6"4'-0" 8'-0" 8'-8"4'-4" 9'-8"5'-6"8'-0"4'-6"9'-0"8'-11"8'-4" 4'-4"3-7 1/4" LVL*WOODRAIL3-2x102'-6"2'-8"2-2x1012x12 BOXEDCOLUMNRADONVENT14" DECKLEDGER2-2x122-11 7/8" LSLCAB. ENDPANEL14'-4"LEGS14'-0"7/6x5/0 SL2-9 1/2" LSL3-11 7/8" LSL9/0x5/0 SL50682'-6"8'-0" CAB.18'-0"2468PKT.84" STACK W & D6'-10"F286828682468LIN.2'-0"7'-8"8'-2"5'-8"3'-4"7'-4" 3'-4"7'-8" 2-2x10 5/0x2/0 FX F32x60 FREESTANDING TUB 3648*C.T.*C.T.*C.T.42'56'BWL 2BWL 3BWL 4BWL 54'4'SEE DETAIL 1/PF-1SEE DETAIL 2/PF-13'3'3'3'3'4'4'4'5'5' Voigt & Associates, Inc.C-1Structural Engineering Services 4635 Nicols Road, Suite 204Eagan, MN 55122MethodCS-WSPWind speed 115Exposure C BWL 1 2 3 4 5Spacing - ft 10 42 42 56 56Level 2 1 1 1 1Length req'd- ft 3.5 6.3 6.3 8.4 8.4per Table R602.10.3(1)Adjustments:Exposure 1.2 1.2 1.2 1.2 1.2Eave to ridge Height 1.13 1.26 1.26 1.26 1.26Wall Height 0.9 0.95 0.95 0.95 0.95# of BWL 1 1 1 1 14" Gyp WB w.block joints1 1 1 1 1Adjusted Length 4.3 9.0 9.0 12.1 12.1Tracy Smith Residence19770 Henning Ave, Lakeville, MNSheet Stone Cottage HVAC Load Calculations for Smith 19770 Henning Ave Lakeville,mn Prepared By: Randy Andrews Lofgren Heating 5708 Upper 147th Street West Apple Vallley, MN 55124 Tuesday, December 7, 2021 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 2 Project Report General Project Information Project Title:Stone Cottage Project Date:Tuesday, December 7, 2021 Client Name:Smith Client Address:19770 Henning Ave Client City:Lakeville,mn Company Name:Lofgren Heating Company Representative:Randy Andrews Company Address:5708 Upper 147th Street West Company City:Apple Vallley, MN 55124 Company E-Mail Address:rrandrews@lofgrenheating-ac.com Design Data Reference City:Minneapolis, Minnesota Building Orientation:Front door faces South Daily Temperature Range:Medium Latitude:44 Degrees Elevation:834 ft. Altitude Factor:0.970 Elevation Sensible Adj. Factor:1.000 Elevation Total Adj. Factor:1.000 Elevation Heating Adj. Factor:1.000 Elevation Heating Adj. Factor:1.000 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter:-15 -15.33 80%n/a 72 n/a Summer:88 72 47%50%75 29 Check Figures Total Building Supply CFM:1,105 CFM Per Square ft.:0.335 Square ft. of Room Area:3,300 Square ft. Per Ton:1,334 Volume (ft³) of Cond. Space:29,700 Building Loads Total Heating Required Including Ventilation Air:50,368 Btuh 50.368 MBH Total Sensible Gain:24,025 Btuh 81 % Total Latent Gain:5,658 Btuh 19 % Total Cooling Required Including Ventilation Air:29,683 Btuh 2.47 Tons (Based On Sensible + Latent) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\19770 HENNING LAKEVILLE 12072021.rhv Tuesday, December 7, 2021, 10:53 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 3 Miscellaneous Report System 1 Whole House Input Data Outdoor Dry Bulb Outdoor Wet Bulb Outdoor Rel.Hum Indoor Rel.Hum Indoor Dry Bulb Grains Difference Winter:-15 -15.33 80%n/a 72 n/a Summer:88 72 47%50%75 29.27 Duct Sizing Inputs Main Trunk Runouts Calculate:Yes Yes Use Schedule:No No Roughness Factor:0.00300 0.01000 Pressure Drop:0.1000 in.wg./100 ft.0.1000 in.wg./100 ft. Minimum Velocity:650 ft./min 450 ft./min Maximum Velocity:900 ft./min 750 ft./min Minimum Height:8 in.6 in. Maximum Height:10 in.6 in. Outside Air Data Winter Summer Infiltration Specified:0.250 AC/hr 0.130 AC/hr 80 CFM 42 CFM Infiltration Actual:0.250 AC/hr 0.130 AC/hr Above Grade Volume:Cu.ft.Cu.ft.X 19,273 X 19,273 4,818 Cu.ft./hr 2,506 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration:80 CFM 42 CFM Total Building Ventilation:140 CFM 70 CFM ---System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 13.87 = (1.10 X 0.970 X 13.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 19.31 = (0.68 X 0.970 X 29.27 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 92.85 = (1.10 X 0.970 X 87.00 Winter Temp. Difference) Winter Infiltration Specified:0.250 AC/hr (80 CFM), Construction: Unknown Summer Infiltration Specified:0.130 AC/hr (42 CFM), Construction: Unknown C:\ ...\19770 HENNING LAKEVILLE 12072021.rhv Tuesday, December 7, 2021, 10:53 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 4 Load Preview Report Scope Has AED Net Ton ft.² /Ton Area Sen Gain Lat Gain Net Gain Sen Loss Sys Htg CFM Sys Clg CFM Sys Act CFM Duct Size Building 2.47 1,334 3,300 24,025 5,658 29,683 50,368 927 1,105 1,105 System 1 Yes 2.47 1,334 3,300 24,025 5,658 29,683 50,368 927 1,105 1,105 21x10 Ventilation 437 1,352 1,789 5,850 Zone 1 3,300 23,588 4,306 27,894 44,518 927 1,105 1,105 21x10 1-Upper Level 1,650 19,782 2,821 22,603 28,964 603 927 927 11--6 2-Lower Level 1,650 3,806 1,485 5,291 15,554 324 178 178 2--6 C:\ ...\19770 HENNING LAKEVILLE 12072021.rhv Tuesday, December 7, 2021, 10:53 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 5 Duct Size Preview Room or Duct Name Minimum Velocity Maximum Velocity Rough. Factor Design L/100 Actual L/100 SP Loss Duct Velocity Duct Length Htg Flow Clg Flow Act. Flow Duct Size System 1 Supply Runouts Zone 1 1-Upper Level 450 750 0 0.1 0.1 429.1 603 927 927 11--6 2-Lower Level 450 750 0 0.1 0.1 454.1 324 178 178 2--6 Other Ducts Supply Main Trunk 650 900 0 0.1 0.1 757.8 927 1,105 1,105 21x10 SummarySummarySummarySummarySummarySummarySummarySummary System 1 Heating Flow:927 Cooling Flow:1105 C:\ ...\19770 HENNING LAKEVILLE 12072021.rhv Tuesday, December 7, 2021, 10:53 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 6 System 1 - Whole House - Adequate Exposure Diversity Test Test For Adequate Exposure Diversity Average Glass Sensible Gain Over 12 Hours 1.3 x Average Glass Gain Hourly Glass Gain Hourly Total Net GainHeat Gain, Btuh21.5% Diff. from Avg. 0 10,000 20,000 30,000 40,000 8 am 9 am 10 am 11 am 12 pm 1 pm 2 pm 3 pm 4 pm 5 pm 6 pm 7 pm AED Calculation Summary --- SYSTEM HAS ADEQUATE EXPOSURE DIVERSITY. --- System is on N, E, S, W rosette. Peak load exceeds 12-hour average load by 21.5%. AED Excursion (amount by which peak exceeds 1.3 x average): 0 Btuh Definition: A system has adequate exposure diversity if the peak-hour glass load for the entire conditioned space does not exceed the average glass load for the entire conditioned space by more than 30 percent. C:\ ...\19770 HENNING LAKEVILLE 12072021.rhv Tuesday, December 7, 2021, 10:53 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 7 System 1 - Whole House - Psychrometric Chart ZC Zone (Room) Condition OC Outdoor Condition LC Leaving Coil Condition EC Entering Coil Condition SD Supply Duct Temperature Rise DTF Draw Through Fan Sensible Gain HRV Heat Recovery Ventilator C:\ ...\19770 HENNING LAKEVILLE 12072021.rhv Tuesday, December 7, 2021, 10:53 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 8 Total Building Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain 4A-1a-o: Glazing-Double pane low-e (e = 0.20 or less), operable window, e=0.20 on surface 2, wood with metal clad frame, u-value 0.32, SHGC 0.33 577 16,064 0 11,409 11,409 11N: Door-Metal - Polystyrene Core 42 1,278 0 352 352 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs 1577 8,918 0 1,364 1,364 15B0-15sf-10: Wall-Basement, , R-15 board insulation to floor, no interior finish, 10' floor depth 1188 4,342 0 0 0 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation 1650 2,871 0 1,584 1,584 21A-24-c: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, no insulation below floor, carpet covering, shortest side of floor slab is 24' wide 1650 3,589 0 0 0 Subtotals for structure:37,062 0 14,709 14,709 People:10 2,000 2,300 4,300 Equipment:1,500 6,000 7,500 Lighting:0 0 0 Ductwork:0 0 0 0 Infiltration: Winter CFM: 80, Summer CFM: 42 7,456 806 579 1,385 Ventilation: Winter CFM: 140, Summer CFM: 70 5,850 1,352 437 1,789 Total Building Load Totals:50,368 5,658 24,025 29,683 Check Figures Total Building Supply CFM:1,105 CFM Per Square ft.:0.335 Square ft. of Room Area:3,300 Square ft. Per Ton:1,334 Volume (ft³) of Cond. Space:29,700 Building Loads Total Heating Required Including Ventilation Air:50,368 Btuh 50.368 MBH Total Sensible Gain:24,025 Btuh 81 % Total Latent Gain:5,658 Btuh 19 % Total Cooling Required Including Ventilation Air:29,683 Btuh 2.47 Tons (Based On Sensible + Latent) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\19770 HENNING LAKEVILLE 12072021.rhv Tuesday, December 7, 2021, 10:53 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 9 Building Pie Chart Building Loss 50,368 Btuh Floor 7% Roof 6% Wall 26% Glass 32% Door 3% Infiltration 15% Ventilation 12% Building Gain 29,683 Btuh Roof 5% Wall 5% Glass 38% Door 1%People 14% Equipment 25% Infiltration 5% Ventilation 6% C:\ ...\19770 HENNING LAKEVILLE 12072021.rhv Tuesday, December 7, 2021, 10:53 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 10 Building Bar Graph Building Loss 50,368 Btuh 0 5,000 10,000 15,000 20,000 Floor 7%Wall 26%Door 3%Ventilation 12% Roof 6%Glass 32%Infiltration 15% Building Gain 29,683 Btuh 0 5,000 10,000 15,000 Roof 5%Glass 38%People 14%Infiltration 5% Wall 5%Door 1%Equipment 25%Ventilation 6% C:\ ...\19770 HENNING LAKEVILLE 12072021.rhv Tuesday, December 7, 2021, 10:53 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 11 System 1 Whole House Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain 4A-1a-o: Glazing-Double pane low-e (e = 0.20 or less), operable window, e=0.20 on surface 2, wood with metal clad frame, u-value 0.32, SHGC 0.33 577 16,064 0 11,409 11,409 11N: Door-Metal - Polystyrene Core 42 1,278 0 352 352 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs 1577 8,918 0 1,364 1,364 15B0-15sf-10: Wall-Basement, , R-15 board insulation to floor, no interior finish, 10' floor depth 1188 4,342 0 0 0 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation 1650 2,871 0 1,584 1,584 21A-24-c: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, no insulation below floor, carpet covering, shortest side of floor slab is 24' wide 1650 3,589 0 0 0 Subtotals for structure:37,062 0 14,709 14,709 People:10 2,000 2,300 4,300 Equipment:1,500 6,000 7,500 Lighting:0 0 0 Ductwork:0 0 0 0 Infiltration: Winter CFM: 80, Summer CFM: 42 7,456 806 579 1,385 Ventilation: Winter CFM: 140, Summer CFM: 70 5,850 1,352 437 1,789 System 1 Whole House Load Totals:50,368 5,658 24,025 29,683 Check Figures Supply CFM:1,105 CFM Per Square ft.:0.335 Square ft. of Room Area:3,300 Square ft. Per Ton:1,334 Volume (ft³) of Cond. Space:29,700 System Loads Total Heating Required Including Ventilation Air:50,368 Btuh 50.368 MBH Total Sensible Gain:24,025 Btuh 81 % Total Latent Gain:5,658 Btuh 19 % Total Cooling Required Including Ventilation Air:29,683 Btuh 2.47 Tons (Based On Sensible + Latent) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\19770 HENNING LAKEVILLE 12072021.rhv Tuesday, December 7, 2021, 10:53 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 12 System 1 Whole House Pie Chart System 1 Whole House Loss 50,368 Btuh Floor 7% Roof 6% Wall 26% Glass 32% Door 3% Infiltration 15% Ventilation 12% System 1 Whole House Gain 29,683 Btuh Roof 5% Wall 5% Glass 38% Door 1%People 14% Equipment 25% Infiltration 5% Ventilation 6% C:\ ...\19770 HENNING LAKEVILLE 12072021.rhv Tuesday, December 7, 2021, 10:53 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 13 System 1 Whole House Bar Graph System 1 Whole House Loss 50,368 Btuh 0 5,000 10,000 15,000 20,000 Floor 7%Wall 26%Door 3%Ventilation 12% Roof 6%Glass 32%Infiltration 15% System 1 Whole House Gain 29,683 Btuh 0 5,000 10,000 15,000 Roof 5%Glass 38%People 14%Infiltration 5% Wall 5%Door 1%Equipment 25%Ventilation 6% C:\ ...\19770 HENNING LAKEVILLE 12072021.rhv Tuesday, December 7, 2021, 10:53 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 14 System 1, Zone 1 Summary Loads (Average Load Procedure for Rooms) Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain 4A-1a-o: Glazing-Double pane low-e (e = 0.20 or less), operable window, e=0.20 on surface 2, wood with metal clad frame, u-value 0.32, SHGC 0.33 577 16,064 0 11,409 11,409 11N: Door-Metal - Polystyrene Core 42 1,278 0 352 352 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs 1577 8,918 0 1,364 1,364 15B0-15sf-10: Wall-Basement, , R-15 board insulation to floor, no interior finish, 10' floor depth 1188 4,342 0 0 0 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation 1650 2,871 0 1,584 1,584 21A-24-c: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, no insulation below floor, carpet covering, shortest side of floor slab is 24' wide 1650 3,589 0 0 0 Subtotals for structure:37,062 0 14,709 14,709 People:10 2,000 2,300 4,300 Equipment:1,500 6,000 7,500 Lighting:0 0 0 Ductwork:0 0 0 0 Infiltration: Winter CFM: 80, Summer CFM: 42 7,456 806 579 1,385 System 1, Zone 1 Load Totals:44,518 4,306 23,588 27,894 Check Figures Supply CFM:1,105 CFM Per Square ft.:0.335 Square ft. of Room Area:3,300 Square ft. Per Ton:1,420 Volume (ft³) of Cond. Space:29,700 Zone Loads Total Heating Required:44,518 Btuh 44.518 MBH Total Sensible Gain:23,588 Btuh 85 % Total Latent Gain:4,306 Btuh 15 % Total Cooling Required:27,894 Btuh 2.32 Tons (Based On Sensible + Latent) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\19770 HENNING LAKEVILLE 12072021.rhv Tuesday, December 7, 2021, 10:53 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 15 System 1, Zone 1 Pie Chart System 1, Zone 1 Loss 44,518 Btuh Floor 8% Roof 6% Wall 30% Glass 36% Door 3% Infiltration 17% System 1, Zone 1 Gain 27,894 Btuh Roof 6% Wall 5% Glass 41% Door 1% People 15% Equipment 27% Infiltration 5% C:\ ...\19770 HENNING LAKEVILLE 12072021.rhv Tuesday, December 7, 2021, 10:53 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 16 System 1, Zone 1 Bar Graph System 1, Zone 1 Loss 44,518 Btuh 0 5,000 10,000 15,000 20,000 Floor 8%Wall 30%Door 3% Roof 6%Glass 36%Infiltration 17% System 1, Zone 1 Gain 27,894 Btuh 0 5,000 10,000 15,000 Roof 6%Glass 41%People 15%Infiltration 5% Wall 5%Door 1%Equipment 27% C:\ ...\19770 HENNING LAKEVILLE 12072021.rhv Tuesday, December 7, 2021, 10:53 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 17 Detailed Room Loads - Room 1 - Upper Level (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:1,650.0 ft.System Number:1 Room Width:1.0 ft.Zone Number:1 Area:1,650.0 sq.ft.Supply Air:927 CFM Ceiling Height:9.0 ft.Supply Air Changes:3.7 AC/hr Volume:14,850.0 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:11 Actual Winter Vent.:91 CFM Runout Air:84 CFM Percent of Supply.:10 % Runout Duct Size:6 in.Actual Summer Vent.:59 CFM Runout Air Velocity:429 ft./min.Percent of Supply:6 % Runout Air Velocity:429 ft./min.Actual Winter Infil.:62 CFM Actual Loss:0.115 in.wg./100 ft.Actual Summer Infil.:32 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain N -Wall-12F-0sw 56 X 9 347 0.065 5.7 1,962 0.9 0 300 S -Wall-12F-0sw 56 X 9 365 0.065 5.7 2,064 0.9 0 316 E -Wall-12F-0sw 38 X 9 252 0.065 5.7 1,425 0.9 0 218 W -Wall-12F-0sw 38 X 9 247 0.065 5.7 1,397 0.9 0 214 S -Door-11N 3 X 7 21 0.350 30.5 639 8.4 0 176 S -Door-11N 3 X 7 21 0.350 30.5 639 8.4 0 176 N -Gls-4A-1a-o shgc-0.33 100%S 157 0.320 27.8 4,371 10.4 0 1,635 S -Gls-4A-1a-o shgc-0.33 0%S 97 0.320 27.8 2,700 19.2 0 1,861 E -Gls-4A-1a-o shgc-0.33 0%S 90 0.320 27.8 2,506 35.0 0 3,150 W -Gls-4A-1a-o shgc-0.33 0%S 95 0.320 27.8 2,645 35.0 0 3,326 UP-Ceil-16B-50 1650 X 1 1650 0.020 1.7 2,871 1.0 0 1,584 Subtotals for Structure:23,219 0 12,956 Infil.: Win.: 61.9, Sum.: 32.2 1,692 3.395 5,745 0.264 621 446 People: 200 lat/per, 230 sen/per:6 1,200 1,380 Equipment:1,000 5,000 Room Totals:28,964 2,821 19,782 C:\ ...\19770 HENNING LAKEVILLE 12072021.rhv Tuesday, December 7, 2021, 10:53 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 18 Detailed Room Loads - Room 2 - Lower Level (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:1,650.0 ft.System Number:1 Room Width:1.0 ft.Zone Number:1 Area:1,650.0 sq.ft.Supply Air:178 CFM Ceiling Height:9.0 ft.Supply Air Changes:0.7 AC/hr Volume:14,850.0 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:2 Actual Winter Vent.:49 CFM Runout Air:89 CFM Percent of Supply.:27 % Runout Duct Size:6 in.Actual Summer Vent.:11 CFM Runout Air Velocity:454 ft./min.Percent of Supply:6 % Runout Air Velocity:454 ft./min.Actual Winter Infil.:18 CFM Actual Loss:0.129 in.wg./100 ft.Actual Summer Infil.:10 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain N -Wall-12F-0sw 56 X 9 366 0.065 5.7 2,070 0.9 0 316 S -Wall-15B0-15sf-10 56 X 9 504 0.042 3.7 1,842 0.0 0 0 E -Wall-15B0-15sf-10 38 X 9 342 0.042 3.7 1,250 0.0 0 0 W -Wall-15B0-15sf-10 38 X 9 342 0.042 3.7 1,250 0.0 0 0 N -Gls-4A-1a-o shgc-0.33 100%S 138 0.320 27.8 3,842 10.4 0 1,437 Floor-21A-24 1 X 1650 1650 0.025 2.2 3,589 0.0 0 0 Subtotals for Structure:13,843 0 1,753 Infil.: Win.: 18.4, Sum.: 9.6 504 3.395 1,711 0.264 185 133 People: 200 lat/per, 230 sen/per:4 800 920 Equipment:500 1,000 Room Totals:15,554 1,485 3,806 C:\ ...\19770 HENNING LAKEVILLE 12072021.rhv Tuesday, December 7, 2021, 10:53 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 19 Room Cooling and Heating Loads Bar Graphs Cooling Heating Btuh Lower Level Upper Level 0 5,000 10,000 15,000 20,000 25,000 30,000 C:\ ...\19770 HENNING LAKEVILLE 12072021.rhv Tuesday, December 7, 2021, 10:53 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 20 Room Cooling Loads Bar Graphs Sensible Latent Btuh Lower Level Upper Level 0 5,000 10,000 15,000 20,000 25,000 C:\ ...\19770 HENNING LAKEVILLE 12072021.rhv Tuesday, December 7, 2021, 10:53 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 21 System 1 Room Load Summary No Room Name Area SF Htg Sens Btuh Min Htg CFM Run Duct Size Run Duct Vel Clg Sens Btuh Clg Lat Btuh Min Clg CFM Act Sys CFM ---Zone 1--- 1 Upper Level 1,650 28,964 603 11-6 429 19,782 2,821 927 927 2 Lower Level 1,650 15,554 324 2-6 454 3,806 1,485 178 178 Ventilation 5,850 437 1,352 System 1 total 3,300 50,368 927 24,025 5,658 1,105 1,105 System 1 Main Trunk Size:21x10 in. Velocity:758 ft./min Loss per 100 ft.:0.085 in.wg Cooling System Summary Cooling Tons Sensible/Latent Split Sensible Btuh Latent Btuh Total Btuh Net Required:2.47 81% / 19%24,025 5,658 29,683 Actual:1.00 77% / 23%9,240 2,760 12,000 Equipment Data Heating System Cooling System Type:Natural Gas Furnace Standard Air Conditioner Model:QC-F38-E78-G QC-C12 Indoor Model:S12 Brand:Quikcool FE Series Quikcool AS Series Description:Hi Efficiency Furnace Standard Efficiency Air Condit Efficiency:78.3 AFUE 12.4 SEER Sound:8.1 bels Capacity:38,000 Btuh 12,000 Btuh Sensible Capacity:n/a 9,240 Btuh Latent Capacity:n/a 2,760 Btuh C:\ ...\19770 HENNING LAKEVILLE 12072021.rhv Tuesday, December 7, 2021, 10:53 AM Builders Associaton of Minnesota version 101014 Date Certificate Posted x Passive (No Fan) Active (With fan and monometer or other system monitoring Location (or future location) of Fan: Other Please Describe Here x 10/15 x x x 20 x 20 x 21 x 49 x x x x x Not applicable, all ducts located in conditioned space x Not required per mech. code Passive Powered Interlocked with exhaust device. Describe:Input in BTUS: 70,000 Capacity in Gallons: Other, describe: AFUE or HSPF% 93% Cfm's " round duct OR " metal duct Not required per mech. code x Passive Low: Other, describe: x Low: Location of fan(s), describe: Cfm's 4" " round duct OR Flex " metal duct ML193UH070 Heating Loss Manufacturer Lennox Natural Gas Output in Tons: 3 Ton50 Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Capacity continuous ventilation rate in cfms: 200CFM Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): 24,025Residential Load Calculation SEER /EER Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Electric Make-up Air Select a Type AO Smith Domestic Water Heater MECHANICAL SYSTEMS Rating or Size Efficiency 13 Seer Building envelope air tightness: Rim Joist (1st Floor) GPVL-50 13ACXN042-230 Model Heating System Natrual Gas Lennox Fiberglass, Batts Foundation Wall R-value Average U-Factor (excludes skylights and one door) U: Duct system air tightness: Cooling SystemTotal R-Value of all Types of InsulationType: Check All That Apply Mineral Fiberboard Insulation Location Foam, Closed Cell0.22 Describe other insulated areas Fiberglass, BlownTHERMAL ENVELOPE Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM Non or Not ApplicableAttic Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area Rim Joist (2nd Floor+) 0.30 Appliances Mech Room Heat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: 50,368 Heating Gain Cooling Load Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. Place your logo here New Construction Energy Code Compliance Certificate Name of Residential Contractor Stone Cottage Construction Inc. MN License Number Lakeville19770 Henning Ave BC636874 City Mailing Address of the Dwelling or Dwelling Unit Combustion Air Select a Type Location of duct or system: 29,683 Below Entire Slab Rigid, Extruded Polystyrene Ceiling, flat NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. New residential building permits WILL NOT be issued without this completed form. Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ Primary Contact: _________________________________________________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Description of Land Disturbing Activity: _____________________________________________________ NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___ If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an erosion and sediment control plan MUST be submitted with the residential building permit application. “The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.” (NPDES Construction Stormwater Permit, MPCA) “The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA) Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name of Person: ________________________________Company: _______________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: ________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots. No land disturbing activity may begin until a residential building permit has been issued. I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 12/16/21 KP X