HomeMy WebLinkAbout17962 Hawksbill Dr SurveyHAVANA PATHPROPOSED
HOUSE
GARAGE
PORCH
HAWKSBILL DRIVE
25.3310.62
10.62
Δ=4°39'18"R=770.0062.56
S89°15'16"W 147.09N09°13'54"
E
7
2
.
3
4N89°15'16"E 148.85S12°35'
5
3
"
W
10.13
22.50 6.00
22.50 10.00
5.00 16.00 8.00 18.00 36.17 12.17 2.00 7.33 7.83 30.50
5
5
5
5 10101010EX. SODEX. SODEXISTINGHOUSE(1007.80)DRAINAGE &UTILITY EASEMENTR:1004.29 R:1004.31
FD IPC.O.GAR FLOOR1006.95GAR FLOOR1007.75FD IPFD IPOS 28.62HUB=998.31OS 26.62HUB=1002.54OS 10.62HUB=1006.30OS 30.12HUB=1005.48R:1004.94EX. SODEX. SODEXISTINGHOUSE1004.9996.8996.81004.91005.8999.01000.01006.11005.41004.91000.6999.2998.6998.81005.11004.61004.71004.8998.3997.61006.8998.4997.9996.8996.5997.8(1004.9)(1006.8)(1002.5)(998.3)(1005.5)(1007.4)(1004.9)(996.8)(996.8)(1006.3)1004.61005.11005.11004.89.5%(998.9)999.1(998.9)(998.9)(998.9)(1007.4)1005.8(1005.8)FBWO
65.08SIDEWALK
POND 3
NWL: 992.0
100YR HWL
:
9
9
6
.
4
T
W
:
1
0
0
2
.
0
TW:998.6DENOTES EXISTING CATCH BASINDENOTES EXISTING HYDRANTDENOTES EXISTING SANITARY MANHOLEDENOTES EXISTING STORM MANHOLEDENOTES EXISTING UTILITY BOXDENOTES EXISTING SERVICE OR CLEANOUTDENOTES IRON MONUMENT FOUNDDENOTES IRON MONUMENT SETDENOTES EXISTING POWER POLEDENOTES EXISTING LIGHT POLEDENOTES EXISTING CONSERVATION POSTOR WET LAND BUFFER POSTDENOTES EXISTING TREE8" TREE000.0DENOTES WOOD HUBDENOTES NAILDENOTES EXISTING RETAINING WALLDENOTES PROPOSED RETAINING WALLDENOTES EXISTING ELEVATIONDENOTES PROPOSED ELEVATIONDENOTES AS BUILT ELEVATION(000.0)000.0DENOTES EXISTING TREELINEDENOTES DIRECTION OF SURFACE DRAINAGEDENOTES EXISTING FENCELEGENDDENOTES EXISTING F.E.S.LOT AREA : 10,581 SQ. FT.HOUSE AREA : 2,013 SQ. FT.PORCH AREA : 128 SQ. FT.BUILDING COVERAGE AREA: 2,141 SQ. FT. (20.2%)Legal Description:= FINISHED GARAGE FLOOR ELEVATION= BASEMENT FLOOR ELEVATION= TOP OF FOUNDATION ELEVATION(1007.80)(1008.13)(999.46)1. No specific soils investigation has been performed on this lotby the surveyor. The suitability of the soils to support thespecific house is not the responsibility of the surveyor.2.No title information was provided for this survey. This surveydoes not purport to show all easements of record.3. See architectural plans for final building dimensions.CERTIFICATE OF SURVEYNOTES:1. MINIMUM BASEMENT FLOOR ELEVATION = 998.92. 24FT. MAXIMUM DRIVEWAY WIDTH AT CURB AND FRONT LOT LINE - WITHOUT A PERMIT.Zoning = RS-4FY - 20' House, 25' GarageSY - 7' Interior, 20' CornerRY - 30'SY Buffer - 30'RY Buffer - 50'*Draintile connection required.EROSION CONTROL MUST BE INSTALLED BEFORE EXCAVATIONThe curb box, drain tile cleanout, and catchbasin(if applicable) must be inspected andaccepted before As-Built escrow monies willbe released. All structures must be flushwith the sod. This will be scheduled with thelandscape inspection.ENGINEERING REVIEWEDDate:__________________01/07/2022JPesik*Maintain 6" between bottom of siding and sod.*No structures in easements.