HomeMy WebLinkAboutLA198569 - 17932 Exeter Cir Permit packRESIDENTIAL BUILDING PERMIT APPLICATION
PAGE 2
OFFICE USE ONLY
BUILDING PERMIT TYPE REQUIRED INSPECTIONS
SINGLE FAMILY DWELLING BUILDING
DUPLEX AS BUILT
TOWNHOUSE UNITS BUILDING FINAL
DETACHED TOWN HOUSE UNIT DECK FOOTING
CONDO FIREPLACE
ACESSORY BUILDING FOOTING
REROOF FOUNDATION
RESIDE FRAMING
PORCH FRAMING
GARAGES
INSULATION
RES ADDN/REPAIR/RMDL
DECK
PORCH
GARAGES LATH
LOWER LEVEL FINISH LOWER LEVEL FINAL
ADDITION OTHER
FOUNDATION ONLY PORCH FOOTING
MISCELLANEOUS POURED WALL
DEMO SEPTIC TANK REMOVAL
MOVED SITE
MECHANICAL
CITY BUILDING VALUATION: $AIR TEST
FINAL
BUILDING PERMIT FEES ROUGH-IN
$PERMIT FEE PLUMBING
$PLAN CHECK FINAL
$SURCHARGE ROUGH-IN
$METRO SAC METER SIZE
$CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE
$CITY SEWER HOOKUP UNIT SEWER/WATER
$LANDSCAPE ESCROW SEWER/WATER
$TREE ESCROW FINAL
$MISC ESCROW STREET DRAINTILE
$PLUMBING BUILDING INFORMATION
$MECHANICAL TYPE OF CONSTRUCTION
$SEWER WATER ZONING
$OTHER CODE EDITION
$TOTAL FIRE SUPPRESSION SYSTEM
OCCUPANCY GROUP
APPROVED BY:
BUILDING INSPECTOR: Date:
PLUMBING/MECHANICAL
INSPECTOR: Date:
COMMENTS:
20195 Holyoke Avenue, Lakeville, MN 55044
952-985-4400 952-985-4499 fax
www.lakevillemn.gov
Sewer & Water Tie Card
Address:________________________________________
Contractor:______________________________________
Permit Number:__________________________________
Final Date:________________
Street Drain-Tile:______
Size of Water Service: 1”
Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS
THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME
OF SEWER & WATER INSPECTION
MAIN FLOOR1' -8 1/4"UPPER PLATE20' -5 1/4"T.O. FOUNDATION0' -0"T.O. FOUNDATION0' -0"MAIN PLATE10' -9 3/8"MAIN PLATE10' -9 3/8"UPPER FLOOR12' -4 1/8"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"UPPER FLOOR PLATE HEIGHT8' - 1 1/8"ALUMINUM SOFFIT& FASCIA TYP.6" SMARTSIDEFRIEZE BOARD TYP.VINYL BOARD &BATTEN TYP.VINYL LAP SIDING & VINYL CORNERS ALL SIDESCULTURED STONE W/CONCRETE CAP4" SMARTSIDE TRIM@ WINDOWS & DOORSTYP. -FRONT ONLYADDRESS STONE6" SMARTSIDE STORYBOARD TYP.4' - 0"42424 AWN FIXEDR.O. 2' -0" x 2' -0"H.H. 2' -6"SEE COLUMN DETAIL SHEET A-5017" / 12"4" / 12"7" / 12"8" 12"GARAGE PLATE HEIGHT10' - 9 3/8"3' - 6"8" 12"1/4" = 1'-0"A-2011FRONT ELEVATIONTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:11/11/2021 12:05:21 PMTHE CAPRIGLIONERESIDENCEL7, B1 - KNOB HILL 3rd ADD'N17932 EXETER CIRCLELAKEVILL, MN 55044A-201OTT2579.22.21 CB1106108478111.11.21 CB9.9.21 CB8'-1 1/8"9'-1 1/8"8'-4" POUR2971THE PAYTON XLSHEET INDEXSHEET NAME SHEET NUMBERELEVATION A-201ELEVATIONS A-202FOUNDATION PLAN A-401LOWER FLOOR A-402MAIN FLOOR A-403UPPER FLOOR A-404ROOF/ WINDOW SCHEDULE A-501DETAILS A-502Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode12/27/2021dmathews
24" RETURNSTYPICAL7" 12"7" 12"7" / 12"8" / 12"8" / 12"8" / 12"ALUMINUM SOFFIT& FASCIA TYP.VINYL SIDING& CORNERS @SIDES & REAR7" / 12"7" 12"4" 12"8" 12"24" RETURNSTYPICAL7" 12"7" 12"4" 12"7" / 12"8" / 12"8" / 12"4:12STANDARD ENERGY HEELS @ 7:12W/ 8:12 TO MATCH FASCIA LINE18" OVERHANGS & 12" RAKES TYP.6 ROOF VENTS @ HOUSE4 ROOF VENTS @ GARAGE7" / 12"7" / 12"8" / 12"8" / 12"7" / 12"8" / 12"8" / 12"8" / 12"8" / 12"7" / 12"7" / 12"4" / 12"4" / 12"STANDARD ENERGY HEELS @ 4:12 W/7:12 & 8:12 TO MATCH FASCIA LINESTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:11/11/2021 12:05:22 PMTHE CAPRIGLIONERESIDENCEL7, B1 - KNOB HILL 3rd ADD'N17932 EXETER CIRCLELAKEVILL, MN 55044A-202OTT2579.22.21 CB1106108478111.11.21 CB9.9.21 CB8'-1 1/8"9'-1 1/8"8'-4" POUR2971THE PAYTON XL1/8" = 1'-0"A-2021LEFT ELEVATION1/8" = 1'-0"A-2022REAR ELEVATION1/8" = 1'-0"A-2023RIGHT ELEVATION1/8" = 1'-0"A-2024ROOF PLANSecure door closed until deck isconstructed with a separate permit.
48' - 0"1' - 10"19' - 10"20' - 2"11' - 0"18' - 10"31' - 2"50' - 0"28' - 2"19' - 10"14' - 0"5' - 10"3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 10"(W) POUREDCONCRETE FOUND. WALL W/4" x 8" EXTERIOR LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE19' - 8"20' - 4"*ALL DIMENSIONS ARE TO OUTSIDE OF CONCRETE48' - 0"15' - 8 1/4"3' - 4 1/2"3' - 11 1/4"3' - 10 3/4"13' - 1 1/4"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.25' - 6"22' - 6"40' - 0"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.0' - 4"26' - 4"16' - 6"11' - 8"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.2' - 0"20' - 6"1' - 11 1/2"16' - 3" M.O.1' - 11 1/2"1' - 1 1/2"8' - 3" M.O.1' - 7 1/2"7'-8"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.40' - 0"10' - 0"3' - 11"7' - 4"0' - 5"14' - 8"LEAVE A 12" GAP IN FOOTINGFOR PLUMBING:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE50' - 0"13' - 2 3/4"26' - 9 1/4"30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.3' - 10 1/2"M.O.3' - 3"2' - 10 1/2"30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAYTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:11/11/2021 12:05:23 PMTHE CAPRIGLIONERESIDENCEL7, B1 - KNOB HILL 3rd ADD'N17932 EXETER CIRCLELAKEVILL, MN 55044A-401OTT2579.22.21 CB1106108478111.11.21 CB9.9.21 CB8'-1 1/8"9'-1 1/8"8'-4" POUR2971THE PAYTON XL1/4" = 1'-0"A-4011FOUNDATION PLANUFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel.
UP 16RUNEXCAVATEDFURNACESUMPW. H.F. D.4' VANITYFAMILY ROOMBEDROOM #4BATH25' - 6"22' - 6"1' - 10"19' - 10"20' - 2"11' - 0"18' - 10"31' - 2"28' - 2"19' - 10"15' - 10"5' - 10"4' - 8"CO DET.SMOKEDET.18" FLOOR TRUSSESPER MFG. SPACING19' - 3 1/2"3' - 8 1/2"3' - 8 1/2"13' - 3 1/2"22/4 x 6/8R.O. 2' -6" x 6' -11"60" F.G. SHWRW/ TILE WALLSCLOSET32/6 x 6/8R.O. 2' -8" x 6' -11"18" FLOOR TRUSSESPER MFG. SPACING14' - 0"5' - 10"11' - 8"16' - 6"UNEXCAVATED10' - 0"40' - 0" (BRACED WALL LINE SPACING)R & SH.2x67' - 7 1/4"1' - 10 3/4"3' - 8"SMOKEDET.*3-1/2" CONC. FLOOR*MECHANICALS MAY VARY19' - 8"20' - 4"*ALL DIMENSIONS ARE TO OUTSIDE OF CONCRETE/SHEATHING2-2x10 W/2 TRIMMERS2-2x102-2x102-2x102-9 1/2" LSL@ 65"12" CANTILEVERABOVE50' - 0"40' - 0"11' - 8"3' - 11"10' - 9"0' - 4"14' - 8"11' - 8"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.4' - 2 1/2"15' - 1"3' - 6"52/8 x 6/8R.O. 2' -10" x 6' -11"MECHANICAL22/4 x 6/8R.O. 2' -6" x 6' -11"AIR EX.2" FOAM INSULATIONBETWEEN WALL & SLAB1' - 11 1/2"16' - 3" M.O.1' - 11 1/2"1' - 1 1/2"8' - 3" M.O.1' - 7 1/2"2' - 0"20' - 6"26' - 4"48' - 0"48' - 0"6' - 9"11' - 0"12' - 9"9' - 6"86048 SLR.O. 5' -0" x 4' -0"H.H. 6' -10"124-48-2448 SLR.O. 8' -0" x 4' -0"H.H. 6' -10"32/6 x 6/8R.O. 2' -8" x 6' -11"50' - 0"STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.136/0 x 6/8 SLIDERR.O. 6' -0" x 6' -8"2-9 1/2" LSL2-9 1/2" LSL3-9 1/2" LVL W/3 TRIMMERS3-2x6CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.15'-6" OF WALL BRACINGREQUIRED. BRACE TO FOUNDATIONOR UNTIL MINIMUM IS MET28' - 0" (BRACED WALL LINE SPACING)15'-6" OF WALL BRACINGREQUIRED. BRACE TO FOUNDATIONOR UNTIL MINIMUM IS METFRAMED GLASS BY-PASS DOORS3' - 10 1/2"M.O.3' - 3"2' - 10 1/2"PATIO12'-0" x 12'-0"3 TRIMMERS CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES1/4" = 1'-0"A-4021LOWER FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:11/11/2021 12:05:24 PMTHE CAPRIGLIONERESIDENCEL7, B1 - KNOB HILL 3rd ADD'N17932 EXETER CIRCLELAKEVILL, MN 55044A-402OTT2579.22.21 CB1106108478111.11.21 CB9.9.21 CB8'-1 1/8"9'-1 1/8"8'-4" POUR2971THE PAYTON XLBWPsAboveFAN
UP 17RDN 16RDN 3RDN 3R22' - 6"25' - 6"28' - 0"20' - 0"50' - 0"3/0 x 6/8 W/12" D.S. SL'S10KITCHENDINING ROOMGREAT ROOMFOYEROFFICEDWGARAGEPORCH1512" TRANSOM / 6/0 x 6/8SLIDER5' - 11"5' - 0"17' - 1"6' - 0"14' - 0"18' - 10"31' - 2"20' - 2"11' - 0"9' - 6"12' - 6"11' - 3"6' - 9"50' - 0"2' - 1"16' - 0"2' - 1"1' - 3"8' - 0"1' - 9"0' - 10"5' - 2"1' - 0"11' - 0"7' - 4"SMOKEDET.2-11 7/8" LSL4' - 2"4' - 0"12" CANT. ABOVE3' - 10"9' - 0"6' - 6"SEE COLUMN DETAIL SHEET A-5014' - 4"5' - 10"0' - 10"15' - 0"18" FLOOR TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSES@ 24" O.C.3-2x10 W/2 TRIMMERS2-9 1/2" LSL W/3 TRIMMERS2-2x10 DROPPED TYP.0' - 4 1/2"20' - 6"2' - 0"62/8 x 6/8 FIRE RATEDR.O. 2' -10" x 6' -10 1/4"2-2x1210' - 0"40' - 0"SNACK BAR19' - 4"20' - 8"4' - 0"1' - 4"PORTAL FRAME W/ HOLD DOWNCS-WSP3' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.SINKSET FIREPLACE @ F.F.HALF HIGH STONE WRAPPED TO EXTERIOR WALL W/ WRAPPED MANTELPOWDER36" REF114/0 x 6/8 BF3/0 x 6/8OPG.92-2x102-2x10 W/2 TRIMMERS2-2x102-11 7/8"LSL FLUSH W/3 TRIMMERS2-2x10 W/2 TRIMMERSPORTAL FRAME W/ HOLD DOWN2-2x102-2X102-2X10CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP5' - 0" B.W.P.2-2X1048' - 0"2' - 0"24' - 0"3' - 2 3/4"5' - 6"3' - 2"1' - 0"3' - 9"1' - 11"3' - 5"4' - 2 1/4"12' - 8 3/4"12' - 2"19' - 8"3' - 8"4' - 6"11' - 6"16' - 6"19' - 3 1/2"3' - 8 1/2"3' - 8 1/2"13' - 3 1/2"2-2x102-9 1/2" LSL FLUSH24" CANTILEVER ABOVE26' - 0"9' - 8"11' - 0"40' - 0"KNEE WALL W/14" SPINDLES2-2x102-11 7/8"LSL FLUSH W/3 TRIMMERS2-11 7/8"LSL FLUSHW/ 2 TRIMMERS5/0 x 6/8OPG.129" HEAT DUCT2' - 0"2' - 0"14' - 3"2' - 10"3' - 1"2' - 10"EQEQ11P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"11P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"11P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"74242 SLR.O. 3' -6" x 3' -6"H.H. 7' -2"63618 PICR.O. 3' -0" x 1' -6"H.H. 8' -0"63618 PICR.O. 3' -0" x 1' -6"H.H. 8' -0"107260 SLR.O. 6' -0" x 5' -0"H.H. 6' -10"32424 AWNR.O. 2' -0" x 2' -0"H.H. 6' -10"ATTICACCESSCS-WSP4' - 0" B.W.P.16" SH.16" SH.PAINTED CABINETSFULL TILE BACKSPLASH12/0 x 6/8R.O. 2' -2" x 6' -11"16' x 8' O.H.GARAGEDOOR168' x 8' O.H.GARAGEDOOR1448' - 0"CS-WSP5' - 0" B.W.P.22/4 x 6/8R.O. 2' -6" x 6' -11"PANTRYPED. SINK4' - 6"2' - 6"4' - 4"1' - 0"GAS F.P.20' - 0"2' - 0"11' - 4"14' - 8"18" FLOOR TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSES@ 24" O.C.MUD ROOMFRAME BOTTOM OFWINDOW @ 44" A.F.F.3-2x6HHUS48LUS4142-2x63-2x62-2x65' - 8"2' - 6"4" CONCRETE SLAB, SLOPETOWARDS DOORS5/8" TYPE X GYP. BD. ALL COMMONWALLS & CEILINGGARAGE PLATE HEIGHT TO MATCHMAIN FLOOR UNLESS NOTED OTHERWISE83/0 x 6/85' - 6"4' - 6"2x6HOT & COLD HOOK UPSSINK30" ELECTRIC RANGE W/ WOOD HOOD ABOVE TECH TUBE & RECEPTACLE ABOVE MICRO PFH2' - 1"PFH2' - 1"PFH1' - 9"2-2x10CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES1/4" = 1'-0"A-4031MAIN FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:11/11/2021 12:05:25 PMTHE CAPRIGLIONERESIDENCEL7, B1 - KNOB HILL 3rd ADD'N17932 EXETER CIRCLELAKEVILL, MN 55044A-403OTT2579.22.21 CB1106108478111.11.21 CB9.9.21 CB8'-1 1/8"9'-1 1/8"8'-4" POUR2971THE PAYTON XLBWPsAboveBWPsAboveFAN
DN 17RBEDROOM #3LAUNDRYBEDROOM #2OWNER'S SUITEHALL1/2 WALL W/WOOD CAPSMOKEDET.SMOKEDET.6' VANITYCLOSETR & SH.SMOKEDET.LOFTGIRDER TRUSSCO DET.SMOKEDET.MFG. ROOF TRUSSESPER MFG. SPACINGATTICACCESS2' LINEN32/6 x 6/8R.O. 2' -8" x 6' -11"42/6 x 6/8 PKTR.O. 5' -2" x 6' -11"4:124:12GIRDERTRUSS13' - 0"27' - 0"3' - 0"28' - 0"29' - 0"2' - 0"26' - 6"13' - 6"R & SH.22/4 x 6/8R.O. 2' -6" x 6' -11"22/4 x 6/8R.O. 2' -6" x 6' -11"6' - 4"14' - 6"5' - 8"6' - 9"6' - 9"32/6 x 6/8R.O. 2' -8" x 6' -11"CLOSETBATH2x63' VANITYR & SH. @ 65"22/4 x 6/8R.O. 2' -6" x 6' -11"0' - 6"22/4 x 6/8R.O. 2' -6" x 6' -11"6' - 6"6' - 6"10' - 0"17' - 0"VAULT LINE2-2x10 W/2 TRIMMERS2-2x102-2x102-2x10CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.40' - 0"5' - 10"22' - 2"31' - 0"31' - 0"40' - 0"7' - 9"5' - 8"5' - 11"4' - 8"5' - 0"8' - 0 1/2"2' - 10 1/2"2' - 7"14' - 6"9' - 1"3' - 7"2' - 6"11' - 8 1/4"3' - 5"3' - 1"6' - 7 3/4"19' - 3 1/2"3' - 8 1/2"3' - 8 1/2"13' - 3 1/2"4' - 4"5' - 0"0' - 10"15' - 10"60" F.G.SHOWER W/ C.T. WALLS& BY-PASSDOORS@ 65"@ 65"2-2x102-2x10 W/2 TRIMMERS52424-2 FIXEDR.O. 4' -0" x 2' -0"H.H. 6' -10"32424 AWNR.O. 2' -0" x 2' -0"H.H. 6' -10"96060 SLR.O. 5' -0" x 5' -0"H.H. 6' -10"86048 SLR.O. 5' -0" x 4' -0"H.H. 6' -10"86048 SLR.O. 5' -0" x 4' -0"H.H. 6' -10"224-48-2460 SLR.O. 8' -0" x 5' -0"H.H. 6' -10"5' TUB/SHWRSMOKEDET.WASHERDRYERDBL FRAMED FOR PLUMBING WALL3' x 5' TUB W/ TILEDECKKNEE WALL W/14" SPINDLESMFG. ROOF TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSESPER MFG. SPACINGEN SUITE72/8 x 6/8 PKTR.O. 5' -6" x 6' -11"32/6 x 6/8R.O. 2' -8" x 6' -11"32/6 x 6/8R.O. 2' -8" x 6' -11"2-2x63-2x63-2x63-2x6R & SH. @ 65"3-2x6CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTESTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:11/11/2021 12:05:25 PMTHE CAPRIGLIONERESIDENCEL7, B1 - KNOB HILL 3rd ADD'N17932 EXETER CIRCLELAKEVILL, MN 55044A-404OTT2579.22.21 CB1106108478111.11.21 CB9.9.21 CB8'-1 1/8"9'-1 1/8"8'-4" POUR2971THE PAYTON XL1/4" = 1'-0"A-4041UPPER FLOOR PLANFANFAN-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).
WATCH DOG WATER PROOF COATINGFROM FOOTING TOSILL SEALER6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETRT'D 2x8 SILL PLATEW/ CLOSED CELL ROLLSILL SEALERGRADEGRANULAR FILL4" DRAIN TILEW/ SILT SOCK1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOORLOWER PLATE HEIGHT8' - 2"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.VERIFY FLOOR SYSTEMWITH FLOOR PLANSUPPER FLOOR PLATE HEIGHT8' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.3/4" T&GSUBFLOOR6 MIL. V.B.2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.1/2" OSBSHEATHINGTYVEK (OR EQUAL)ROLL HOUSE WRAPSIDING, VERIFYW/ ELEVATIONS5/8" GYP. BD.5/8" GYP. BD.VENTED ALUMINUMSOFFIT PANELSICE & WATER GUARDFROM EAVE TO 2'-0"MIN. OVER STRUCTUREVENT CHUTES & WIND WASH@ EACH TRUSS SPACEASPHALT SHINGLES W/15# ROLL FELT UNDER1/2" OSB ROOF SHEATHINGMFG. ROOFTRUSSES @ 24" O.C.ATTIC VENTINGAS PER CODER-49 MIN. BLOWNATTIC INSULATIONALUMINUM FASCIA W/2x6 SUB FASCIAALUMINUMDRIP EDGERIM JOISTRIM JOISTR-20 MIN. SPRAYFOAM INSULATION,COVER FOUNDATION WALLGMX THERMAL DRAINAGE BOARD(R-10) INSULATIONDRYVIT INSULATIONPROTECTION FROM SIDINGTO 6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITH OUTSIDE OF SHEATINGR-20 MIN. SPRAYFOAM INSULATION1' - 5"0' - 9 1/2"2x4 @ BOTTOM1x3 TYP.2x22x4 @ TOPSMOOTH LPSMARTSIDE TYP.SOFFIT1' - 9 1/2"1' - 0"FRONTSIDETOP VIEW1' - 5"0' - 9 1/2"FRAMING4x4 POSTTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:11/11/2021 12:05:26 PMTHE CAPRIGLIONERESIDENCEL7, B1 - KNOB HILL 3rd ADD'N17932 EXETER CIRCLELAKEVILL, MN 55044A-501OTT2579.22.21 CB1106108478111.11.21 CB9.9.21 CB8'-1 1/8"9'-1 1/8"8'-4" POUR2971THE PAYTON XL3" MIN. ABS OR PVC GASTIGHTPIPE FROM SUBSLAB TOMIN. 12" ABOVE ROOF, MUSTBE RUN THRU CONDITIONED SPACE.PIPE CAN BE CONNECTED TOSUMP SYSTEM OR HAVE"T" FITTING (MIN. 10'-0" EA. WAY)IN GRAVEL UNDER SLAB.END OF PIPE MUST BE MIN. 10'-0"AWAY FROM ANY WINDOW OROTHER OPENING THAT IS LESSTHAN 2'-0" BELOW END OF PIPE. END OF PIPE MUST ALSO BEMIN. 10'-0" AWAY FROM ANYWINDOW OR OTHER OPENING INADJOINING OR ADJACENTBUILDINGS.SUFFICIENT SPACE MUST BELEFT AROUND PIPE IN ATTIC SPACETO ADD FAN. SPACE MUST BEMIN. ∅24" CENTERED ON AXIS OFPIPE W/ MIN. 3'-0" VERTICAL SPACE.A SINGLE PIPE CAN BE USED IF ALLSOIL GASES IN DWELLING CANFLOW FREELY BETWEEN ALL LEVELSOF FOUNDATION. THIS INCLUDESINTERIOR FOOTINGS & OTHERBARRIERS IF AIRFLOW HASBEEN ESTABLISHED.LABEL THE VENT PIPE AT LEASTONCE PER FLOOR AND INACCESSIBLE ATTICS WITH"RADON REDUCTION SYSTEM".ONE ELECTRICAL RECEPTACLE ISREQUIRED IN THE ATTIC NEARTHE VENT PIPE FOR OPT. FAN.:PASSIVE RADON SYSTEM:3/8" = 1'-0"A-5012TYP. WALL SECTIONWINDOW SCHEDULETYPE MARK MANUFACTURER MODEL COUNT UNIT ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT1 WINDSOR NEXT DIMENSION 1 24-48-2448 SL 8' - 0" 4' - 0" 6' - 10"2 WINDSOR NEXT DIMENSION 1 24-48-2460 SL 8' - 0" 5' - 0" 6' - 10"3 WINDSOR NEXT DIMENSION 2 2424 AWN 2' - 0" 2' - 0" 6' - 10"4 WINDSOR NEXT DIMENSION 1 2424 AWN FIXED 2' - 0" 2' - 0"2' - 6"5 WINDSOR NEXT DIMENSION 1 2424-2 FIXED 4' - 0" 2' - 0" 6' - 10"6 WINDSOR NEXT DIMENSION 2 3618 PIC 3' - 0" 1' - 6" 8' - 0"7 WINDSOR NEXT DIMENSION 1 4242 SL 3' - 6" 3' - 6" 7' - 2"8 WINDSOR NEXT DIMENSION 3 6048 SL 5' - 0" 4' - 0" 6' - 10"9 WINDSOR NEXT DIMENSION 1 6060 SL 5' - 0" 5' - 0" 6' - 10"10 WINDSOR NEXT DIMENSION 1 7260 SL 6' - 0" 5' - 0" 6' - 10"11 WINDSOR NEXT DIMENSION 3 P4260/A24 T 3' - 6" 7' - 0" 8' - 0"1/2" = 1'-0"A-5013TYP. COLUMNROOM FINISHED SCHEDULEFLOOR ROOM NAME FLOOR AREA PLATE HEIGHT COMMENTSLOWER FLOOR FAMILY ROOM CARPET 431 SF 8' - 2" .LOWER FLOOR BEDROOM #4 CARPET 153 SF 8' - 2" .LOWER FLOOR CLOSET CARPET 65 SF 8' - 2" .LOWER FLOOR STAIRWAY CARPET 66 SF 8' - 2"LOWER FLOOR MECHANICAL CONCRETE 182 SF 8' - 2" FINISH PER CODELOWER FLOOR PATIO CONCRETE 144 SF 8' - 2" 12'-0" x 12'-0"LOWER FLOOR BATH VINYL 51 SF 8' - 2" .MAIN FLOOR OFFICE CARPET 122 SF 9' - 1 1/8" .MAIN FLOOR STAIRWAY CARPET 77 SF 9' - 1 1/8"MAIN FLOOR GARAGE CONCRETE 627 SF 10' - 9 3/8"MAIN FLOOR PORCH CONCRETE 113 SF 9' - 1 1/8" .MAIN FLOOR MUD ROOM VINYL 61 SF 9' - 1 1/8" .MAIN FLOOR POWDER VINYL 33 SF 9' - 1 1/8" .MAIN FLOOR KITCHEN WOOD 177 SF 9' - 1 1/8" .MAIN FLOOR DINING ROOM WOOD 110 SF 9' - 1 1/8" .MAIN FLOOR GREAT ROOM WOOD 244 SF 9' - 1 1/8" .MAIN FLOOR FOYER WOOD 118 SF 9' - 1 1/8" .MAIN FLOOR PANTRY WOOD 30 SF 9' - 1 1/8" .UPPER FLOOR BEDROOM #3 CARPET 143 SF 8' - 1 1/8" .UPPER FLOOR BEDROOM #2 CARPET 139 SF 8' - 1 1/8" .UPPER FLOOR OWNER'S SUITE CARPET 181 SF 8' - 1 1/8" VAULTEDUPPER FLOOR HALL CARPET 77 SF 8' - 1 1/8" .UPPER FLOOR LOFT CARPET 137 SF 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 55 SF 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 25 SF 8' - 1 1/8" .UPPER FLOOR LAUNDRY VINYL 32 SF 8' - 1 1/8" .UPPER FLOOR EN SUITE VINYL 93 SF 8' - 1 1/8" .UPPER FLOOR BATH VINYL 42 SF 8' - 1 1/8" .DOOR SCHEDULETYPE MARK DOOR SIZE ROUGH WIDTH ROUGH HEIGHT COUNT COMMENTS1 2/0 x 6/8 2' - 2" 6' - 11" 12 2/4 x 6/8 2' - 6" 6' - 11" 73 2/6 x 6/8 2' - 8" 6' - 11" 64 2/6 x 6/8 PKT 5' - 2" 6' - 11" 15 2/8 x 6/8 2' - 10" 6' - 11" 16 2/8 x 6/8 FIRE RATED 2' - 10" 6' - 10 1/4" 17 2/8 x 6/8 PKT 5' - 6" 6' - 11" 18 3/0 x 6/819 3/0 x 6/8 OPG.110 3/0 x 6/8 W/ 12" D.S. SL'S111 4/0 x 6/8 BF112 5/0 x 6/8 OPG.113 6/0 x 6/8 SLIDER 6' - 0" 6' - 8" 114 8' x 8' O.H. GARAGE DOOR115 12" TRANSOM / 6/0 x 6/8 SLIDER116 16' x 8' O.H. GARAGE DOOR1
6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"5000 PSI CONCRETE@ ALL FOOTINGS2" FOAMBOARD(R-10) INSULATION4" DRAIN TILEW/ SILT SOCKWATER PROOF COATING FROM FOOTING TOSILL SEALERANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" OSBSHEATHINGRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESTOOP, FLASH AS REQ'DAT HOUSE WALLPOUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERSIDING, VERIFYW/ ELEVATIONSTYVEK (OR EQUAL) ROLL HOUSE WRAP0' - 2"FROM SHEATHING TOOUTSIDE OF FOUNDATIONANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLAN3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION5/8" TYPE 'X' GYP BOARD,TAPE & MUD ALL SEAMSRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESLAB, FLASH AS REQ'DAT HOUSE WALL0' - 4"POUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALER0' - 8"FASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP.MIN. 3/8" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).MIN. 1000 LB HOLD-DOWNDEVICE (EMBEDDED INTOCONCRETE & NAILEDINTO FRAMING)FRONT ELEVATIONMIN. FOOTING SIZE UNDER OPENING IS12" X 12". A TURNED DOWN SLAB SHALLBE PERMITTED AT DOOR OPENINGS.MIN. (1) 5/8" DIA. ANCHOR BOLDINSTALLED PER R403.1.6 W/2" X 2" X 3/16" PLATE WASHER.MIN. REINFORCING OF FOUNDATION,ONE #4 BAR TOP & BOTTOM OFFOOTING. LAP BARS 15" MINIMUM.MIN. (2) 4200 LB STRAP-TYPE HOLD-DOWNS (EMBEDDED INTO CONCRETEAND NAILED INTO FRAMING)MIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 3/8" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INALL FRAMING (STUDS, BLOCKING AND SILLS) TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED9' - 11 1/4" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTAL2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.TRT'D SILL PLATEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSSLEEVE EVERY10'-0" MIN.6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODE5000 PSI CONCRETE@ ALL FOOTINGSWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESINSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONDRYVIT INSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITHOUTSIDE OF SHEATHINGTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:11/11/2021 12:05:27 PMTHE CAPRIGLIONERESIDENCEL7, B1 - KNOB HILL 3rd ADD'N17932 EXETER CIRCLELAKEVILL, MN 55044A-502OTT2579.22.21 CB1106108478111.11.21 CB9.9.21 CB8'-1 1/8"9'-1 1/8"8'-4" POUR2971THE PAYTON XL1/2" = 1'-0"A-5021TYP. WALKOUT SECTION1/2" = 1'-0"A-5022TYP. HOUSE/STOOP WALL1/2" = 1'-0"A-5023TYP. HOUSE/GARAGE WALL3/8" = 1'-0"A-5024METHOD PFH - PORTAL FRAME WITH HOLD-DOWNS1/2" = 1'-0"A-5025BEARING WALL SECTION1/2" = 1'-0"A-5026TYP. LOOKOUT SECTION
MAIN FLOOR1' -8 1/4"UPPER PLATE20' -5 1/4"T.O. FOUNDATION0' -0"T.O. FOUNDATION0' -0"MAIN PLATE10' -9 3/8"MAIN PLATE10' -9 3/8"UPPER FLOOR12' -4 1/8"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"UPPER FLOOR PLATE HEIGHT8' - 1 1/8"ALUMINUM SOFFIT& FASCIA TYP.6" SMARTSIDEFRIEZE BOARD TYP.VINYL BOARD &BATTEN TYP.VINYL LAP SIDING & VINYL CORNERS ALL SIDESCULTURED STONE W/CONCRETE CAP4" SMARTSIDE TRIM@ WINDOWS & DOORSTYP. -FRONT ONLYADDRESS STONE6" SMARTSIDE STORYBOARD TYP.4' - 0"42424 AWN FIXEDR.O. 2' -0" x 2' -0"H.H. 2' -6"SEE COLUMN DETAIL SHEET A-5017" / 12"4" / 12"7" / 12"8" 12"GARAGE PLATE HEIGHT10' - 9 3/8"3' - 6"8" 12"1/4" = 1'-0"A-2011FRONT ELEVATIONTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:9/22/2021 9:21:17 AMTHE CAPRIGLIONERESIDENCEL7, B1 - KNOB HILL 3rd ADD'N17932 EXETER CIRCLELAKEVILL, MN 55044A-201OTT2579.22.21 CB110610847819.9.21 CB8'-1 1/8"9'-1 1/8"8'-4" POUR2971THE PAYTON XLSHEET INDEXSHEET NAME SHEET NUMBERELEVATION A-201ELEVATIONS A-202FOUNDATION PLAN A-401LOWER FLOOR A-402MAIN FLOOR A-403UPPER FLOOR A-404ROOF/ WINDOW SCHEDULE A-501DETAILS A-502
24" RETURNSTYPICAL7" 12"7" 12"7" / 12"8" / 12"8" / 12"8" / 12"ALUMINUM SOFFIT& FASCIA TYP.VINYL SIDING& CORNERS @SIDES & REAR7" / 12"7" 12"4" 12"8" 12"24" RETURNSTYPICAL7" 12"7" 12"4" 12"7" / 12"8" / 12"8" / 12"4:12STANDARD ENERGY HEELS @ 7:12W/ 8:12 TO MATCH FASCIA LINE18" OVERHANGS & 12" RAKES TYP.6 ROOF VENTS @ HOUSE4 ROOF VENTS @ GARAGE7" / 12"7" / 12"8" / 12"8" / 12"7" / 12"8" / 12"8" / 12"8" / 12"8" / 12"7" / 12"7" / 12"4" / 12"4" / 12"STANDARD ENERGY HEELS @ 4:12 W/7:12 & 8:12 TO MATCH FASCIA LINESTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:9/22/2021 9:21:19 AMTHE CAPRIGLIONERESIDENCEL7, B1 - KNOB HILL 3rd ADD'N17932 EXETER CIRCLELAKEVILL, MN 55044A-202OTT2579.22.21 CB110610847819.9.21 CB8'-1 1/8"9'-1 1/8"8'-4" POUR2971THE PAYTON XL1/8" = 1'-0"A-2021LEFT ELEVATION1/8" = 1'-0"A-2022REAR ELEVATION1/8" = 1'-0"A-2023RIGHT ELEVATION1/8" = 1'-0"A-2024ROOF PLAN
48' - 0"1' - 10"19' - 10"20' - 2"11' - 0"18' - 10"31' - 2"50' - 0"28' - 2"19' - 10"14' - 0"5' - 10"3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 10"(W) POUREDCONCRETE FOUND. WALL W/4" x 8" EXTERIOR LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE19' - 8"20' - 4"*ALL DIMENSIONS ARE TO OUTSIDE OF CONCRETE48' - 0"15' - 8 1/4"3' - 4 1/2"3' - 11 1/4"3' - 10 3/4"13' - 1 1/4"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.25' - 6"22' - 6"40' - 0"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.0' - 4"26' - 4"16' - 6"11' - 8"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.2' - 0"20' - 6"1' - 11 1/2"16' - 3" M.O.1' - 11 1/2"1' - 1 1/2"8' - 3" M.O.1' - 7 1/2"7'-8"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.40' - 0"10' - 0"3' - 11"7' - 4"0' - 5"14' - 8"LEAVE A 12" GAP IN FOOTINGFOR PLUMBING:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE50' - 0"13' - 2 3/4"26' - 9 1/4"30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.3' - 10 1/2"M.O.3' - 3"2' - 10 1/2"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:9/22/2021 9:21:19 AMTHE CAPRIGLIONERESIDENCEL7, B1 - KNOB HILL 3rd ADD'N17932 EXETER CIRCLELAKEVILL, MN 55044A-401OTT2579.22.21 CB110610847819.9.21 CB8'-1 1/8"9'-1 1/8"8'-4" POUR2971THE PAYTON XL1/4" = 1'-0"A-4011FOUNDATION PLAN
UP 16RUNEXCAVATEDFURNACESUMPW. H.F. D.4' VANITYFAMILY ROOMBEDROOM #4BATH25' - 6"22' - 6"1' - 10"19' - 10"20' - 2"11' - 0"18' - 10"31' - 2"28' - 2"19' - 10"15' - 10"5' - 10"4' - 8"CO DET.SMOKEDET.18" FLOOR TRUSSESPER MFG. SPACING19' - 3 1/2"3' - 8 1/2"3' - 8 1/2"13' - 3 1/2"22/4 x 6/8R.O. 2' -6" x 6' -11"60" F.G. SHWRW/ TILE WALLSCLOSET32/6 x 6/8R.O. 2' -8" x 6' -11"18" FLOOR TRUSSESPER MFG. SPACING14' - 0"5' - 10"11' - 8"16' - 6"UNEXCAVATED10' - 0"40' - 0" (BRACED WALL LINE SPACING)R & SH.2x67' - 7 1/4"1' - 10 3/4"3' - 8"SMOKEDET.*3-1/2" CONC. FLOOR*MECHANICALS MAY VARY19' - 8"20' - 4"*ALL DIMENSIONS ARE TO OUTSIDE OF CONCRETE/SHEATHING2-2x10 W/2 TRIMMERS2-2x102-2x102-2x102-9 1/2" LSL@ 65"12" CANTILEVERABOVE50' - 0"40' - 0"11' - 8"3' - 11"10' - 9"0' - 4"14' - 8"11' - 8"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.4' - 2 1/2"15' - 1"3' - 6"52/8 x 6/8R.O. 2' -10" x 6' -11"MECHANICAL22/4 x 6/8R.O. 2' -6" x 6' -11"AIR EX.2" FOAM INSULATIONBETWEEN WALL & SLAB1' - 11 1/2"16' - 3" M.O.1' - 11 1/2"1' - 1 1/2"8' - 3" M.O.1' - 7 1/2"2' - 0"20' - 6"26' - 4"48' - 0"48' - 0"6' - 9"11' - 0"12' - 9"9' - 6"86048 SLR.O. 5' -0" x 4' -0"H.H. 6' -10"124-48-2448 SLR.O. 8' -0" x 4' -0"H.H. 6' -10"32/6 x 6/8R.O. 2' -8" x 6' -11"50' - 0"STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.136/0 x 6/8 SLIDERR.O. 6' -0" x 6' -8"2-9 1/2" LSL2-9 1/2" LSL3-9 1/2" LVL W/3 TRIMMERS3-2x6CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.15'-6" OF WALL BRACINGREQUIRED. BRACE TO FOUNDATIONOR UNTIL MINIMUM IS MET28' - 0" (BRACED WALL LINE SPACING)15'-6" OF WALL BRACINGREQUIRED. BRACE TO FOUNDATIONOR UNTIL MINIMUM IS METFRAMED GLASS BY-PASS DOORS3' - 10 1/2"M.O.3' - 3"2' - 10 1/2"PATIO12'-0" x 12'-0"1/4" = 1'-0"A-4021LOWER FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:9/22/2021 9:21:20 AMTHE CAPRIGLIONERESIDENCEL7, B1 - KNOB HILL 3rd ADD'N17932 EXETER CIRCLELAKEVILL, MN 55044A-402OTT2579.22.21 CB110610847819.9.21 CB8'-1 1/8"9'-1 1/8"8'-4" POUR2971THE PAYTON XLCS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTESHeader Spans:Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ***3 Trimmers
UP 17RDN 16RDN 3RDN 3R22' - 6"25' - 6"28' - 0"20' - 0"50' - 0"3/0 x 6/8 W/12" D.S. SL'S10KITCHENDINING ROOMGREAT ROOMFOYEROFFICEDWGARAGEPORCH1512" TRANSOM / 6/0 x 6/8SLIDER5' - 11"5' - 0"17' - 1"6' - 0"14' - 0"18' - 10"31' - 2"20' - 2"11' - 0"9' - 6"12' - 6"11' - 3"6' - 9"50' - 0"2' - 1"16' - 0"2' - 1"1' - 3"8' - 0"1' - 9"0' - 10"5' - 2"1' - 0"11' - 0"7' - 4"SMOKEDET.2-11 7/8" LSL4' - 2"4' - 0"12" CANT. ABOVE3' - 10"9' - 0"6' - 6"SEE COLUMN DETAIL SHEET A-5014' - 4"5' - 10"0' - 10"15' - 0"18" FLOOR TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSES@ 24" O.C.3-2x10 W/2 TRIMMERS2-9 1/2" LSL W/3 TRIMMERS2-2x10TYP.0' - 4 1/2"20' - 6"2' - 0"62/8 x 6/8 FIRE RATEDR.O. 2' -10" x 6' -10 1/4"2-2x1210' - 0"40' - 0"SNACK BAR19' - 4"20' - 8"4' - 0"1' - 4"PORTAL FRAME W/ HOLD DOWNCS-WSP3' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.SINKSET FIREPLACE @ F.F.HALF HIGH STONE WRAPPED TO EXTERIOR WALL W/ WRAPPED MANTELPOWDER36" REF114/0 x 6/8 BF3/0 x 6/8OPG.92-2x102-2X10 W/2 TRIMMERS2-2x102-11 7/8"LSL FLUSH W/3 TRIMMERS2-2x10 W/2 TRIMMERSPORTAL FRAME W/ HOLD DOWN2-2x102-2X102-2X10CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP5' - 0" B.W.P.2-2X1048' - 0"2' - 0"24' - 0"3' - 2 3/4"5' - 6"3' - 2"1' - 0"3' - 9"1' - 11"3' - 5"4' - 2 1/4"12' - 8 3/4"12' - 2"19' - 8"8' - 2"11' - 6"16' - 6"19' - 3 1/2"3' - 8 1/2"3' - 8 1/2"13' - 3 1/2"2-2x102-9 1/2" LSL24" CANTILEVER ABOVE26' - 0"9' - 8"11' - 0"40' - 0"KNEE WALL W/14" SPINDLES2-2X102-11 7/8"LSL FLUSH W/3 TRIMMERS2-11 7/8"LSL FLUSHW/ 2 TRIMMERS5/0 x 6/8OPG.129" HEAT DUCT2' - 0"2' - 0"14' - 3"2' - 10"3' - 1"2' - 10"EQEQ11P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"11P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"11P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"74242 SLR.O. 3' -6" x 3' -6"H.H. 7' -2"63618 PICR.O. 3' -0" x 1' -6"H.H. 8' -0"63618 PICR.O. 3' -0" x 1' -6"H.H. 8' -0"107260 SLR.O. 6' -0" x 5' -0"H.H. 6' -10"32424 AWNR.O. 2' -0" x 2' -0"H.H. 6' -10"ATTICACCESSCS-WSP4' - 0" B.W.P.16" SH.16" SH.PAINTED CABINETSFULL TILE BACKSPLASH12/0 x 6/8R.O. 2' -2" x 6' -11"16' x 8' O.H.GARAGEDOOR168' x 8' O.H.GARAGEDOOR1448' - 0"CS-WSP5' - 0" B.W.P.22/4 x 6/8R.O. 2' -6" x 6' -11"PANTRYPED. SINK4' - 6"2' - 6"4' - 4"1' - 0"GAS F.P.20' - 0"2' - 0"11' - 4"14' - 8"18" FLOOR TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSES@ 24" O.C.MUD ROOMFRAME BOTTOM OFWINDOW @ 44" A.F.F.3-2x6HHUS410HHUS4102-2x63-2x62-2x65' - 8"2' - 6"4" CONCRETE SLAB, SLOPETOWARDS DOORS5/8" TYPE X GYP. BD. ALL COMMONWALLS & CEILINGGARAGE PLATE HEIGHT TO MATCHMAIN FLOOR UNLESS NOTED OTHERWISE83/0 x 6/85' - 6"4' - 6"2x6HOT & COLD HOOK UPSSINK30" ELECTRIC RANGE W/ WOOD HOOD ABOVE TECH TUBE & RECEPTACLE ABOVE MICRO 1/4" = 1'-0"A-4031MAIN FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:9/22/2021 9:21:21 AMTHE CAPRIGLIONERESIDENCEL7, B1 - KNOB HILL 3rd ADD'N17932 EXETER CIRCLELAKEVILL, MN 55044A-403OTT2579.22.21 CB110610847819.9.21 CB8'-1 1/8"9'-1 1/8"8'-4" POUR2971THE PAYTON XLCS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTESHeader Spans:Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ***2-2x10
DN 17RBEDROOM #3LAUNDRYBEDROOM #2OWNER'S SUITEHALL1/2 WALL W/WOOD CAPSMOKEDET.SMOKEDET.6' VANITYCLOSETR & SH.SMOKEDET.LOFTGIRDER TRUSSCO DET.SMOKEDET.MFG. ROOF TRUSSESPER MFG. SPACINGATTICACCESS2' LINEN32/6 x 6/8R.O. 2' -8" x 6' -11"42/6 x 6/8 PKTR.O. 5' -2" x 6' -11"4:124:12GIRDERTRUSS13' - 0"27' - 0"3' - 0"28' - 0"29' - 0"2' - 0"26' - 6"13' - 6"R & SH.22/4 x 6/8R.O. 2' -6" x 6' -11"22/4 x 6/8R.O. 2' -6" x 6' -11"6' - 4"14' - 6"5' - 8"6' - 9"6' - 9"32/6 x 6/8R.O. 2' -8" x 6' -11"CLOSETBATH2x63' VANITYR & SH. @ 65"22/4 x 6/8R.O. 2' -6" x 6' -11"0' - 6"22/4 x 6/8R.O. 2' -6" x 6' -11"6' - 6"6' - 6"10' - 0"17' - 0"VAULT LINE2-2x10 W/2 TRIMMERS2-2x102-2x102-2x10CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.40' - 0"5' - 10"22' - 2"31' - 0"31' - 0"40' - 0"7' - 9"5' - 8"5' - 11"4' - 8"5' - 0"8' - 0 1/2"2' - 10 1/2"2' - 7"14' - 6"9' - 1"3' - 7"2' - 6"11' - 8 1/4"3' - 5"3' - 1"6' - 7 3/4"19' - 3 1/2"3' - 8 1/2"3' - 8 1/2"13' - 3 1/2"4' - 4"5' - 0"0' - 10"15' - 10"60" F.G.SHOWER W/ C.T. WALLS& BY-PASSDOORS@ 65"@ 65"2-2x102-2x10 W/2 TRIMMERS52424-2 FIXEDR.O. 4' -0" x 2' -0"H.H. 6' -10"32424 AWNR.O. 2' -0" x 2' -0"H.H. 6' -10"96060 SLR.O. 5' -0" x 5' -0"H.H. 6' -10"86048 SLR.O. 5' -0" x 4' -0"H.H. 6' -10"86048 SLR.O. 5' -0" x 4' -0"H.H. 6' -10"224-48-2460 SLR.O. 8' -0" x 5' -0"H.H. 6' -10"5' TUB/SHWRSMOKEDET.WASHERDRYERDBL FRAMED FOR PLUMBING WALL3' x 5' TUB W/ TILEDECKKNEE WALL W/14" SPINDLESMFG. ROOF TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSESPER MFG. SPACINGEN SUITE72/8 x 6/8 PKTR.O. 5' -6" x 6' -11"32/6 x 6/8R.O. 2' -8" x 6' -11"32/6 x 6/8R.O. 2' -8" x 6' -11"2-2x63-2x63-2x63-2x6R & SH. @ 65"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:9/22/2021 9:21:22 AMTHE CAPRIGLIONERESIDENCEL7, B1 - KNOB HILL 3rd ADD'N17932 EXETER CIRCLELAKEVILL, MN 55044A-404OTT2579.22.21 CB110610847819.9.21 CB8'-1 1/8"9'-1 1/8"8'-4" POUR2971THE PAYTON XL1/4" = 1'-0"A-4041UPPER FLOOR PLANCS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTESHeader Spans:Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ***3-2x6
WATCH DOG WATER PROOF COATINGFROM FOOTING TOSILL SEALER6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETRT'D 2x8 SILL PLATEW/ CLOSED CELL ROLLSILL SEALERGRADEGRANULAR FILL4" DRAIN TILEW/ SILT SOCK1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOORLOWER PLATE HEIGHT8' - 2"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.VERIFY FLOOR SYSTEMWITH FLOOR PLANSUPPER FLOOR PLATE HEIGHT8' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.3/4" T&GSUBFLOOR6 MIL. V.B.2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.1/2" OSBSHEATHINGTYVEK (OR EQUAL)ROLL HOUSE WRAPSIDING, VERIFYW/ ELEVATIONS5/8" GYP. BD.5/8" GYP. BD.VENTED ALUMINUMSOFFIT PANELSICE & WATER GUARDFROM EAVE TO 2'-0"MIN. OVER STRUCTUREVENT CHUTES & WIND WASH@ EACH TRUSS SPACEASPHALT SHINGLES W/15# ROLL FELT UNDER1/2" OSB ROOF SHEATHINGMFG. ROOFTRUSSES @ 24" O.C.ATTIC VENTINGAS PER CODER-49 MIN. BLOWNATTIC INSULATIONALUMINUM FASCIA W/2x6 SUB FASCIAALUMINUMDRIP EDGERIM JOISTRIM JOISTR-20 MIN. SPRAYFOAM INSULATION,COVER FOUNDATION WALLGMX THERMAL DRAINAGE BOARD(R-10) INSULATIONDRYVIT INSULATIONPROTECTION FROM SIDINGTO 6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITH OUTSIDE OF SHEATINGR-20 MIN. SPRAYFOAM INSULATION1' - 5"0' - 9 1/2"2x4 @ BOTTOM1x3 TYP.2x22x4 @ TOPSMOOTH LPSMARTSIDE TYP.SOFFIT1' - 9 1/2"1' - 0"FRONTSIDETOP VIEW1' - 5"0' - 9 1/2"FRAMING4x4 POSTTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:9/22/2021 9:21:23 AMTHE CAPRIGLIONERESIDENCEL7, B1 - KNOB HILL 3rd ADD'N17932 EXETER CIRCLELAKEVILL, MN 55044A-501OTT2579.22.21 CB110610847819.9.21 CB8'-1 1/8"9'-1 1/8"8'-4" POUR2971THE PAYTON XL3" MIN. ABS OR PVC GASTIGHTPIPE FROM SUBSLAB TOMIN. 12" ABOVE ROOF, MUSTBE RUN THRU CONDITIONED SPACE.PIPE CAN BE CONNECTED TOSUMP SYSTEM OR HAVE"T" FITTING (MIN. 10'-0" EA. WAY)IN GRAVEL UNDER SLAB.END OF PIPE MUST BE MIN. 10'-0"AWAY FROM ANY WINDOW OROTHER OPENING THAT IS LESSTHAN 2'-0" BELOW END OF PIPE. END OF PIPE MUST ALSO BEMIN. 10'-0" AWAY FROM ANYWINDOW OR OTHER OPENING INADJOINING OR ADJACENTBUILDINGS.SUFFICIENT SPACE MUST BELEFT AROUND PIPE IN ATTIC SPACETO ADD FAN. SPACE MUST BEMIN. ∅24" CENTERED ON AXIS OFPIPE W/ MIN. 3'-0" VERTICAL SPACE.A SINGLE PIPE CAN BE USED IF ALLSOIL GASES IN DWELLING CANFLOW FREELY BETWEEN ALL LEVELSOF FOUNDATION. THIS INCLUDESINTERIOR FOOTINGS & OTHERBARRIERS IF AIRFLOW HASBEEN ESTABLISHED.LABEL THE VENT PIPE AT LEASTONCE PER FLOOR AND INACCESSIBLE ATTICS WITH"RADON REDUCTION SYSTEM".ONE ELECTRICAL RECEPTACLE ISREQUIRED IN THE ATTIC NEARTHE VENT PIPE FOR OPT. FAN.:PASSIVE RADON SYSTEM:3/8" = 1'-0"A-5012TYP. WALL SECTIONWINDOW SCHEDULETYPE MARK MANUFACTURER MODEL COUNT UNIT ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT1 WINDSOR NEXT DIMENSION 1 24-48-2448 SL 8' - 0" 4' - 0" 6' - 10"2 WINDSOR NEXT DIMENSION 1 24-48-2460 SL 8' - 0" 5' - 0" 6' - 10"3 WINDSOR NEXT DIMENSION 2 2424 AWN 2' - 0" 2' - 0" 6' - 10"4 WINDSOR NEXT DIMENSION 1 2424 AWN FIXED 2' - 0" 2' - 0"2' - 6"5 WINDSOR NEXT DIMENSION 1 2424-2 FIXED 4' - 0" 2' - 0" 6' - 10"6 WINDSOR NEXT DIMENSION 2 3618 PIC 3' - 0" 1' - 6" 8' - 0"7 WINDSOR NEXT DIMENSION 1 4242 SL 3' - 6" 3' - 6" 7' - 2"8 WINDSOR NEXT DIMENSION 3 6048 SL 5' - 0" 4' - 0" 6' - 10"9 WINDSOR NEXT DIMENSION 1 6060 SL 5' - 0" 5' - 0" 6' - 10"10 WINDSOR NEXT DIMENSION 1 7260 SL 6' - 0" 5' - 0" 6' - 10"11 WINDSOR NEXT DIMENSION 3 P4260/A24 T 3' - 6" 7' - 0" 8' - 0"1/2" = 1'-0"A-5013TYP. COLUMNROOM FINISHED SCHEDULEFLOOR ROOM NAME FLOOR AREA PLATE HEIGHT COMMENTSLOWER FLOOR FAMILY ROOM CARPET 431 SF 8' - 2" .LOWER FLOOR BEDROOM #4 CARPET 153 SF 8' - 2" .LOWER FLOOR CLOSET CARPET 65 SF 8' - 2" .LOWER FLOOR STAIRWAY CARPET 66 SF 8' - 2"LOWER FLOOR MECHANICAL CONCRETE 182 SF 8' - 2" FINISH PER CODELOWER FLOOR PATIO CONCRETE 144 SF 8' - 2" 12'-0" x 12'-0"LOWER FLOOR BATH VINYL 51 SF 8' - 2" .MAIN FLOOR OFFICE CARPET 122 SF 9' - 1 1/8" .MAIN FLOOR STAIRWAY CARPET 77 SF 9' - 1 1/8"MAIN FLOOR GARAGE CONCRETE 627 SF 10' - 9 3/8"MAIN FLOOR PORCH CONCRETE 113 SF 9' - 1 1/8" .MAIN FLOOR MUD ROOM VINYL 61 SF 9' - 1 1/8" .MAIN FLOOR POWDER VINYL 33 SF 9' - 1 1/8" .MAIN FLOOR KITCHEN WOOD 177 SF 9' - 1 1/8" .MAIN FLOOR DINING ROOM WOOD 110 SF 9' - 1 1/8" .MAIN FLOOR GREAT ROOM WOOD 244 SF 9' - 1 1/8" .MAIN FLOOR FOYER WOOD 118 SF 9' - 1 1/8" .MAIN FLOOR PANTRY WOOD 30 SF 9' - 1 1/8" .UPPER FLOOR BEDROOM #3 CARPET 143 SF 8' - 1 1/8" .UPPER FLOOR BEDROOM #2 CARPET 139 SF 8' - 1 1/8" .UPPER FLOOR OWNER'S SUITE CARPET 181 SF 8' - 1 1/8" VAULTEDUPPER FLOOR HALL CARPET 77 SF 8' - 1 1/8" .UPPER FLOOR LOFT CARPET 137 SF 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 55 SF 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 25 SF 8' - 1 1/8" .UPPER FLOOR LAUNDRY VINYL 32 SF 8' - 1 1/8" .UPPER FLOOR EN SUITE VINYL 93 SF 8' - 1 1/8" .UPPER FLOOR BATH VINYL 42 SF 8' - 1 1/8" .DOOR SCHEDULETYPE MARK DOOR SIZE ROUGH WIDTH ROUGH HEIGHT COUNT COMMENTS1 2/0 x 6/8 2' - 2" 6' - 11" 12 2/4 x 6/8 2' - 6" 6' - 11" 73 2/6 x 6/8 2' - 8" 6' - 11" 64 2/6 x 6/8 PKT 5' - 2" 6' - 11" 15 2/8 x 6/8 2' - 10" 6' - 11" 16 2/8 x 6/8 FIRE RATED 2' - 10" 6' - 10 1/4" 17 2/8 x 6/8 PKT 5' - 6" 6' - 11" 18 3/0 x 6/819 3/0 x 6/8 OPG.110 3/0 x 6/8 W/ 12" D.S. SL'S111 4/0 x 6/8 BF112 5/0 x 6/8 OPG.113 6/0 x 6/8 SLIDER 6' - 0" 6' - 8" 114 8' x 8' O.H. GARAGE DOOR115 12" TRANSOM / 6/0 x 6/8 SLIDER116 16' x 8' O.H. GARAGE DOOR1
6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"5000 PSI CONCRETE@ ALL FOOTINGS2" FOAMBOARD(R-10) INSULATION4" DRAIN TILEW/ SILT SOCKWATER PROOF COATING FROM FOOTING TOSILL SEALERANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" OSBSHEATHINGRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESTOOP, FLASH AS REQ'DAT HOUSE WALLPOUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERSIDING, VERIFYW/ ELEVATIONSTYVEK (OR EQUAL) ROLL HOUSE WRAP0' - 2"FROM SHEATHING TOOUTSIDE OF FOUNDATIONANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLAN3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION5/8" TYPE 'X' GYP BOARD,TAPE & MUD ALL SEAMSRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESLAB, FLASH AS REQ'DAT HOUSE WALL0' - 4"POUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALER0' - 8"FASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP.MIN. 3/8" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).MIN. 1000 LB HOLD-DOWNDEVICE (EMBEDDED INTOCONCRETE & NAILEDINTO FRAMING)FRONT ELEVATIONMIN. FOOTING SIZE UNDER OPENING IS12" X 12". A TURNED DOWN SLAB SHALLBE PERMITTED AT DOOR OPENINGS.MIN. (1) 5/8" DIA. ANCHOR BOLDINSTALLED PER R403.1.6 W/2" X 2" X 3/16" PLATE WASHER.MIN. REINFORCING OF FOUNDATION,ONE #4 BAR TOP & BOTTOM OFFOOTING. LAP BARS 15" MINIMUM.MIN. (2) 4200 LB STRAP-TYPE HOLD-DOWNS (EMBEDDED INTO CONCRETEAND NAILED INTO FRAMING)MIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 3/8" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INALL FRAMING (STUDS, BLOCKING AND SILLS) TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED9' - 11 1/4" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTAL2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.TRT'D SILL PLATEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSSLEEVE EVERY10'-0" MIN.6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODE5000 PSI CONCRETE@ ALL FOOTINGSWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESINSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONDRYVIT INSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITHOUTSIDE OF SHEATHINGTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:9/22/2021 9:21:24 AMTHE CAPRIGLIONERESIDENCEL7, B1 - KNOB HILL 3rd ADD'N17932 EXETER CIRCLELAKEVILL, MN 55044A-502OTT2579.22.21 CB110610847819.9.21 CB8'-1 1/8"9'-1 1/8"8'-4" POUR2971THE PAYTON XL1/2" = 1'-0"A-5021TYP. WALKOUT SECTION1/2" = 1'-0"A-5022TYP. HOUSE/STOOP WALL1/2" = 1'-0"A-5023TYP. HOUSE/GARAGE WALL3/8" = 1'-0"A-5024METHOD PFH - PORTAL FRAME WITH HOLD-DOWNS1/2" = 1'-0"A-5025BEARING WALL SECTION1/2" = 1'-0"A-5026TYP. LOOKOUT SECTION
Upper Level
Member Name Results Current Solution Comments
Loft/Bedroom #2 Window Passed 2 piece(s) 2 x 10 SPF No.1/No.2
Bedroom #3 Window Passed 2 piece(s) 2 x 10 SPF No.1/No.2
Closet Window Passed 2 piece(s) 2 x 10 SPF No.1/No.2
Stair Landing Window Passed 2 piece(s) 2 x 10 SPF No.1/No.2
Main Level
Member Name Results Current Solution Comments
Kitchen Window Passed 2 piece(s) 2 x 10 SPF No.1/No.2
Dining Room Patio Door Passed 3 piece(s) 2 x 10 SPF No.1/No.2
Great Room Window Passed 2 piece(s) 2 x 10 SPF No.1/No.2
Office Window Passed 2 piece(s) 2 x 10 SPF No.1/No.2
Drop Front Porch (H)Passed 2 piece(s) 2 x 10 SPF No.1/No.2
Flush Stairs (H)Passed 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL
Foyer Front Door Passed 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL
Garage 16' OHD Passed 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL
Garage 8' OHD Passed 2 piece(s) 2 x 12 SPF No.1/No.2
Mudroom Door Passed 2 piece(s) 2 x 10 SPF No.1/No.2
Mudroom Kitchen Opening Passed 2 piece(s) 2 x 10 SPF No.1/No.2
Flush Pantry (H)Passed 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL
Flush Foyer (H)Passed 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL
Flush Foyer (V)Passed 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL
Lower Level
Member Name Results Current Solution Comments
Bedroom Window Passed 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL
Family Room Patio Door Passed 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL
Family Room End Window Passed 3 piece(s) 1 3/4" x 9 1/2" 2.0E Microllam® LVL
Mechanical Room Door Passed 2 piece(s) 2 x 10 SPF No.1/No.2
Bathroom Door Passed 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL
Bedroom Closet Door Passed 2 piece(s) 2 x 10 SPF No.1/No.2
17932 Exeter Circle, Lakeville, MN
JOB SUMMARY REPORT
ForteWEB Software Operator Job Notes 11/6/2021 3:46:35 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.2
File Name: 17932 Exeter Circle, Lakeville, MN
Topaz - Payton XL
17932 Exeter Circle, Lakeville, MN
11/6/21; #25165
Page 1 / 26
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)2288 @ 1 1/2"3825 (3.00")Passed (60%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)1439 @ 1' 1/4"2872 Passed (50%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)2867 @ 2' 9"3946 Passed (73%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.032 @ 2' 9"0.175 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.051 @ 2' 9"0.262 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Trimmer - SPF 3.00"3.00"1.79"844 1444 2288 None
2 - Trimmer - SPF 3.00"3.00"1.79"844 1444 2288 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)5' 6" o/c
Bottom Edge (Lu)5' 6" o/c
Dead Snow
Vertical Loads Location Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 5' 6"N/A 7.0 --
1 - Uniform (PSF)0 to 5' 6"15'20.0 35.0 Snow - Main
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 9/22/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Upper Level, Loft/Bedroom #2 Window
2 piece(s) 2 x 10 SPF No.1/No.2
ForteWEB Software Operator Job Notes 11/6/2021 3:46:35 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
File Name: 17932 Exeter Circle, Lakeville, MN
Topaz - Payton XL
17932 Exeter Circle, Lakeville, MN
11/6/21; #25165
Page 2 / 26
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)2288 @ 1 1/2"3825 (3.00")Passed (60%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)1439 @ 1' 1/4"2872 Passed (50%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)2867 @ 2' 9"3946 Passed (73%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.032 @ 2' 9"0.175 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.051 @ 2' 9"0.262 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Trimmer - SPF 3.00"3.00"1.79"844 1444 2288 None
2 - Trimmer - SPF 3.00"3.00"1.79"844 1444 2288 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)5' 6" o/c
Bottom Edge (Lu)5' 6" o/c
Dead Snow
Vertical Loads Location Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 5' 6"N/A 7.0 --
1 - Uniform (PSF)0 to 5' 6"15'20.0 35.0 Snow - Main
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 9/22/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Upper Level, Bedroom #3 Window
2 piece(s) 2 x 10 SPF No.1/No.2
ForteWEB Software Operator Job Notes 11/6/2021 3:46:35 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
File Name: 17932 Exeter Circle, Lakeville, MN
Topaz - Payton XL
17932 Exeter Circle, Lakeville, MN
11/6/21; #25165
Page 3 / 26
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)306 @ 0 1913 (1.50")Passed (16%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)62 @ 10 3/4"2872 Passed (2%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)172 @ 1' 1 1/2"3946 Passed (4%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.000 @ 1' 1 1/2"0.075 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.001 @ 1' 1 1/2"0.112 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Trimmer - SPF 1.50"1.50"1.50"188 118 306 None
2 - Trimmer - SPF 1.50"1.50"1.50"188 118 306 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)2' 3" o/c
Bottom Edge (Lu)2' 3" o/c
Dead Snow
Vertical Loads Location Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 2' 3"N/A 7.0 --
1 - Uniform (PSF)0 to 2' 3"3'20.0 35.0 Snow - Main
2 - Uniform (PLF)0 to 2' 3"N/A 100.0 -Wall - Gable
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 9/22/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Upper Level, Closet Window
2 piece(s) 2 x 10 SPF No.1/No.2
ForteWEB Software Operator Job Notes 11/6/2021 3:46:35 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
File Name: 17932 Exeter Circle, Lakeville, MN
Topaz - Payton XL
17932 Exeter Circle, Lakeville, MN
11/6/21; #25165
Page 4 / 26
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)1768 @ 0 1913 (1.50")Passed (92%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)1023 @ 10 3/4"2872 Passed (36%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)1879 @ 2' 1 1/2"3946 Passed (48%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.014 @ 2' 1 1/2"0.142 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.022 @ 2' 1 1/2"0.213 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Trimmer - SPF 1.50"1.50"1.50"652 1116 1768 None
2 - Trimmer - SPF 1.50"1.50"1.50"652 1116 1768 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)4' 3" o/c
Bottom Edge (Lu)4' 3" o/c
Dead Snow
Vertical Loads Location Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 4' 3"N/A 7.0 --
1 - Uniform (PSF)0 to 4' 3"15'20.0 35.0 Snow - Main
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 9/22/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Upper Level, Stair Landing Window
2 piece(s) 2 x 10 SPF No.1/No.2
ForteWEB Software Operator Job Notes 11/6/2021 3:46:35 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
File Name: 17932 Exeter Circle, Lakeville, MN
Topaz - Payton XL
17932 Exeter Circle, Lakeville, MN
11/6/21; #25165
Page 5 / 26
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)1143 @ 0 1913 (1.50")Passed (60%)--1.0 D + 1.0 L (All Spans)
Shear (lbs)597 @ 10 3/4"2498 Passed (24%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)1071 @ 1' 10 1/2"3431 Passed (31%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.006 @ 1' 10 1/2"0.125 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.010 @ 1' 10 1/2"0.188 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Trimmer - SPF 1.50"1.50"1.50"430 713 1143 None
2 - Trimmer - SPF 1.50"1.50"1.50"430 713 1143 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)3' 9" o/c
Bottom Edge (Lu)3' 9" o/c
Dead Floor Live
Vertical Loads Location Tributary Width (0.90)(1.00)Comments
0 - Self Weight (PLF)0 to 3' 9"N/A 7.0 --
1 - Uniform (PSF)0 to 3' 9"9' 6"15.0 40.0 Floor - Upper Level
2 - Uniform (PSF)0 to 3' 9"1'80.0 -Wall - Upper Level
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 9/22/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Kitchen Window
2 piece(s) 2 x 10 SPF No.1/No.2
ForteWEB Software Operator Job Notes 11/6/2021 3:46:35 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
File Name: 17932 Exeter Circle, Lakeville, MN
Topaz - Payton XL
17932 Exeter Circle, Lakeville, MN
11/6/21; #25165
Page 6 / 26
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)4079 @ 1 1/2"5738 (3.00")Passed (71%)--1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (lbs)2888 @ 1' 1/4"4308 Passed (67%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans)
Moment (Ft-lbs)5323 @ 2'5919 Passed (90%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans)
Live Load Defl. (in)0.046 @ 3' 1 1/16"0.208 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)0.083 @ 3' 1 1/8"0.313 Passed (L/900)--1.0 D + 0.75 L + 0.75 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Trimmer - SPF 3.00"3.00"2.13"1815 1105 1913 4833 None
2 - Trimmer - SPF 3.00"3.00"1.50"1046 1105 581 2732 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)6' 6" o/c
Bottom Edge (Lu)6' 6" o/c
Dead Floor Live Snow
Vertical Loads Location Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)0 to 6' 6"N/A 10.6 ----
1 - Uniform (PSF)0 to 6' 6"8' 6"15.0 40.0 -Floor - Upper Level
2 - Uniform (PSF)0 to 6' 6"1'80.0 --Wall - Upper Level
3 - Uniform (PSF)0 to 2'15'20.0 -35.0 Snow - Main
4 - Point (lb)2'N/A 844 -1444 Linked from: Loft
Window, Support 1
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 9/22/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Dining Room Patio Door
3 piece(s) 2 x 10 SPF No.1/No.2
ForteWEB Software Operator Job Notes 11/6/2021 3:46:35 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
File Name: 17932 Exeter Circle, Lakeville, MN
Topaz - Payton XL
17932 Exeter Circle, Lakeville, MN
11/6/21; #25165
Page 7 / 26
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)5786 @ 3' 9 3/4"5738 (4.50")Passed (101%)--1.0 D + 0.75 L + 0.75 S (Adj Spans)
Shear (lbs)2430 @ 6' 8 3/4"2872 Passed (85%)1.15 1.0 D + 1.0 S (Alt Spans)
Moment (Ft-lbs)-2244 @ 3' 9 3/4"3946 Passed (57%)1.15 1.0 D + 0.75 L + 0.75 S (Adj Spans)
Live Load Defl. (in)0.008 @ 5' 9 3/4"0.129 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (Alt Spans)
Total Load Defl. (in)0.012 @ 5' 10"0.194 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (Alt Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Trimmer - SPF 1.50"1.50"1.50"728 584/-67 787 2099/-
67 None
2 - Trimmer - SPF 4.50"4.50"4.54"2513 1566 2799 6878 None
3 - Trimmer - SPF 4.50"4.50"3.26"1783 1566 1604 4953 None
4 - Trimmer - SPF 3.00"3.00"2.05"1107 626/-67 1384 3117/-
67 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)11' 8" o/c
Bottom Edge (Lu)11' 8" o/c
Dead Floor Live Snow
Vertical Loads Location Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)0 to 11' 7 1/2"N/A 7.0 ----
1 - Uniform (PSF)0 to 11' 7 1/2"8' 6"15.0 40.0 -Floor - Upper Level
2 - Uniform (PSF)0 to 11' 7 1/2"1'80.0 --Wall - Upper Level
3 - Uniform (PSF)0 to 6' 6"15'20.0 -35.0 Snow - Main
4 - Point (lb)6' 6"N/A 844 -1444
Linked from:
Bedroom # 2
Window, Support 1
5 - Point (lb)11' 6"N/A 844 -1444
Linked from:
Bedroom # 2
Window, Support 2
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 9/22/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Great Room Window
2 piece(s) 2 x 10 SPF No.1/No.2
ForteWEB Software Operator Job Notes 11/6/2021 3:46:35 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
File Name: 17932 Exeter Circle, Lakeville, MN
Topaz - Payton XL
17932 Exeter Circle, Lakeville, MN
11/6/21; #25165
Page 8 / 26
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)2612 @ 1 1/2"3825 (3.00")Passed (68%)--1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (lbs)1484 @ 1' 1/4"2498 Passed (59%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)2916 @ 3' 3"3431 Passed (85%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.040 @ 3' 3"0.208 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)0.081 @ 3' 3"0.313 Passed (L/924)--1.0 D + 0.75 L + 0.75 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Trimmer - SPF 3.00"3.00"2.05"1398 910 709 3017 None
2 - Trimmer - SPF 3.00"3.00"2.05"1398 910 709 3017 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)6' 6" o/c
Bottom Edge (Lu)6' 6" o/c
Dead Floor Live Snow
Vertical Loads Location Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)0 to 6' 6"N/A 7.0 ----
1 - Uniform (PSF)0 to 6' 6"7'15.0 40.0 -Floor - Upper Level
2 - Uniform (PSF)0 to 6' 6"1'80.0 --Wall - Upper Level
3 - Uniform (PSF)0 to 6' 6"3'20.0 -35.0 Snow - Porch
4 - Point (lb)9"N/A 459 -289 Bedroom # 3
Window
5 - Point (lb)5' 9"N/A 459 -289 Bedroom # 3
Window
6 - Uniform (PSF)0 to 9"3'20.0 -35.0 Snow - Main
7 - Uniform (PSF)5' 9" to 6' 6"3'20.0 -35.0 Snow - Main
8 - Uniform (PSF)0 to 9"1'100.0 --Wall - Gable
9 - Uniform (PSF)5' 9" to 6' 6"1'100.0 --Wall - Gable
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 9/22/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Office Window
2 piece(s) 2 x 10 SPF No.1/No.2
ForteWEB Software Operator Job Notes 11/6/2021 3:46:35 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
File Name: 17932 Exeter Circle, Lakeville, MN
Topaz - Payton XL
17932 Exeter Circle, Lakeville, MN
11/6/21; #25165
Page 9 / 26
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)3338 @ 7' 7"7013 (5.50")Passed (48%)--1.0 D + 1.0 S (Adj Spans)
Shear (lbs)1561 @ 8' 7"2872 Passed (54%)1.15 1.0 D + 1.0 S (Adj Spans)
Moment (Ft-lbs)-3305 @ 7' 7"3946 Passed (84%)1.15 1.0 D + 1.0 S (Adj Spans)
Live Load Defl. (in)0.122 @ 13' 6 1/2"0.367 Passed (L/999+)--1.0 D + 1.0 S (Alt Spans)
Total Load Defl. (in)0.189 @ 13' 6 7/8"0.550 Passed (L/700)--1.0 D + 1.0 S (Alt Spans)
System : Roof
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Member Pitch : 0/12
•Deflection criteria: LL (L/360) and TL (L/240).
•Overhang deflection criteria: LL (2L/360) and TL (2L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Stud wall - SPF 3.00"3.00"1.50"245 506 751 Blocking
2 - Stud wall - SPF 5.50"5.50"2.62"1264 2074 3338 Blocking
3 - Stud wall - SPF 5.50"5.50"1.50"587 982 1569 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)12' 1" o/c
Bottom Edge (Lu)8' 11" o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 19' 7"N/A 7.0 --
1 - Uniform (PSF)0 to 19' 7" (Front)5'20.0 35.0 Snow - Porch
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 9/22/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Drop Front Porch (H)
2 piece(s) 2 x 10 SPF No.1/No.2
ForteWEB Software Operator Job Notes 11/6/2021 3:46:35 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
File Name: 17932 Exeter Circle, Lakeville, MN
Topaz - Payton XL
17932 Exeter Circle, Lakeville, MN
11/6/21; #25165
Page 10 / 26
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)5631 @ 11' 2"8181 (5.50")Passed (69%)--1.0 D + 1.0 L (All Spans)
Shear (lbs)3777 @ 10' 5/8"8590 Passed (44%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)10448 @ 6' 1 1/4"15953 Passed (65%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.227 @ 5' 10"0.271 Passed (L/573)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.328 @ 5' 10 1/4"0.542 Passed (L/396)--1.0 D + 1.0 L (All Spans)
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/480) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Stud wall - SPF 5.50"5.50"2.32"1033 2419 66 3518 Blocking
2 - Stud wall - SPF 5.50"5.50"3.79"2153 3478 1013 6644 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)10' o/c
Bottom Edge (Lu)11' 6" o/c
Dead Floor Live Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)0 to 11' 6"N/A 13.0 ----
1 - Uniform (PSF)0 to 4' (Front)8' 6"15.0 40.0 -Floor - Upper Level
2 - Uniform (PSF)4' to 10' 6" (Front)13'15.0 40.0 -Floor - Upper Level
3 - Uniform (PSF)10' 6" to 11' 6" (Front)14'15.0 40.0 -Floor - Upper Level
4 - Point (lb)10' 6" (Front)N/A 1049 597 1079
Linked from: Flush
Foyer (V), Support
2
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 9/22/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Flush Stairs (H)
2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL
ForteWEB Software Operator Job Notes 11/6/2021 3:46:35 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
File Name: 17932 Exeter Circle, Lakeville, MN
Topaz - Payton XL
17932 Exeter Circle, Lakeville, MN
11/6/21; #25165
Page 11 / 26
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)10340 @ 5' 10 1/2"11419 (4.50")Passed (91%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)559 @ 1' 1/2"7902 Passed (7%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)1179 @ 3'11985 Passed (10%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.014 @ 3'0.192 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.023 @ 3'0.287 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Trimmer - SPF 3.00"3.00"1.50"331 -525 856 None
2 - Trimmer - SPF 4.50"4.50"4.07"4564 931 5776 11271 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)6' 2" o/c
Bottom Edge (Lu)6' 2" o/c
Dead Floor Live Snow
Vertical Loads Location Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)0 to 6' 1 1/2"N/A 10.4 ----
1 - Uniform (PSF)0 to 6' 1 1/2"5'20.0 -35.0 Snow - Porch
2 - Point (lb)6' 1 1/2"N/A 4219 931 5229
Linked from: Flush
Foyer (V), Support
1
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 9/22/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Foyer Front Door
2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL
ForteWEB Software Operator Job Notes 11/6/2021 3:46:35 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
File Name: 17932 Exeter Circle, Lakeville, MN
Topaz - Payton XL
17932 Exeter Circle, Lakeville, MN
11/6/21; #25165
Page 12 / 26
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)2328 @ 1 1/2"7613 (3.00")Passed (31%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)1984 @ 1' 2 7/8"9878 Passed (20%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)9460 @ 8' 4 1/2"18346 Passed (52%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.244 @ 8' 4 1/2"0.550 Passed (L/811)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.646 @ 8' 4 1/2"0.825 Passed (L/306)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Trimmer - SPF 3.00"3.00"1.50"1449 879 2328 None
2 - Trimmer - SPF 3.00"3.00"1.50"1449 879 2328 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)11' 9" o/c
Bottom Edge (Lu)16' 9" o/c
Dead Snow
Vertical Loads Location Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 16' 9"N/A 13.0 --
1 - Uniform (PLF)0 to 16' 9"N/A 160.0 105.0 Snow - Gable End
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 9/22/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Garage 16' OHD
2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL
ForteWEB Software Operator Job Notes 11/6/2021 3:46:35 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
File Name: 17932 Exeter Circle, Lakeville, MN
Topaz - Payton XL
17932 Exeter Circle, Lakeville, MN
11/6/21; #25165
Page 13 / 26
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)1197 @ 1 1/2"3825 (3.00")Passed (31%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)872 @ 1' 2 1/4"3493 Passed (25%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)2470 @ 4' 4 1/2"5306 Passed (47%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.025 @ 4' 4 1/2"0.283 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.064 @ 4' 4 1/2"0.425 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Trimmer - SPF 3.00"3.00"1.50"737 459 1196 None
2 - Trimmer - SPF 3.00"3.00"1.50"737 459 1196 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)8' 9" o/c
Bottom Edge (Lu)8' 9" o/c
Dead Snow
Vertical Loads Location Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 8' 9"N/A 8.6 --
1 - Uniform (PSF)0 to 8' 9"3'20.0 35.0 Snow - Garage
2 - Uniform (PSF)0 to 8' 9"1'100.0 -Wall - Gable
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 9/22/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Garage 8' OHD
2 piece(s) 2 x 12 SPF No.1/No.2
ForteWEB Software Operator Job Notes 11/6/2021 3:46:35 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
File Name: 17932 Exeter Circle, Lakeville, MN
Topaz - Payton XL
17932 Exeter Circle, Lakeville, MN
11/6/21; #25165
Page 14 / 26
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)1192 @ 0 1913 (1.50")Passed (62%)--1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (lbs)499 @ 10 3/4"2872 Passed (17%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans)
Moment (Ft-lbs)919 @ 1' 6 1/2"3946 Passed (23%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans)
Live Load Defl. (in)0.003 @ 1' 6 1/2"0.103 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)0.006 @ 1' 6 1/2"0.154 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Trimmer - SPF 1.50"1.50"1.50"550 370 486 1406 None
2 - Trimmer - SPF 1.50"1.50"1.50"550 370 486 1406 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)3' 1" o/c
Bottom Edge (Lu)3' 1" o/c
Dead Floor Live Snow
Vertical Loads Location Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)0 to 3' 1"N/A 7.0 ----
1 - Uniform (PSF)0 to 3' 1"6'15.0 40.0 -Floor - Upper Level
2 - Uniform (PSF)0 to 3' 1"1'80.0 --Wall - Upper Level
3 - Uniform (PSF)0 to 3' 1"9'20.0 -35.0 Snow - Main
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 9/22/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Mudroom Door
2 piece(s) 2 x 10 SPF No.1/No.2
ForteWEB Software Operator Job Notes 11/6/2021 3:46:35 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
File Name: 17932 Exeter Circle, Lakeville, MN
Topaz - Payton XL
17932 Exeter Circle, Lakeville, MN
11/6/21; #25165
Page 15 / 26
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)1501 @ 0 1913 (1.50")Passed (78%)--1.0 D + 1.0 L (All Spans)
Shear (lbs)694 @ 10 3/4"2498 Passed (28%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)1251 @ 1' 8"3431 Passed (36%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.007 @ 1' 8"0.111 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.009 @ 1' 8"0.167 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Trimmer - SPF 1.50"1.50"1.50"418 1083 1501 None
2 - Trimmer - SPF 1.50"1.50"1.50"418 1083 1501 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)3' 4" o/c
Bottom Edge (Lu)3' 4" o/c
Dead Floor Live
Vertical Loads Location Tributary Width (0.90)(1.00)Comments
0 - Self Weight (PLF)0 to 3' 4"N/A 7.0 --
1 - Uniform (PSF)0 to 3' 4"16' 3"15.0 40.0 Floor - Upper Level
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 9/22/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Mudroom Kitchen Opening
2 piece(s) 2 x 10 SPF No.1/No.2
ForteWEB Software Operator Job Notes 11/6/2021 3:46:35 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
File Name: 17932 Exeter Circle, Lakeville, MN
Topaz - Payton XL
17932 Exeter Circle, Lakeville, MN
11/6/21; #25165
Page 16 / 26
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)2932 @ 1 1/2"4463 (3.00")Passed (66%)--1.0 D + 1.0 L (All Spans)
Shear (lbs)2176 @ 1' 1/2"6872 Passed (32%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)5564 @ 4' 1/2"10422 Passed (53%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.131 @ 4' 1/2"0.196 Passed (L/715)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.183 @ 4' 1/2"0.392 Passed (L/512)--1.0 D + 1.0 L (All Spans)
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/480) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Stud wall - SPF 3.00"3.00"1.97"830 2102 2932 Blocking
2 - Stud wall - SPF 3.00"3.00"1.97"830 2102 2932 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)8' 1" o/c
Bottom Edge (Lu)8' 1" o/c
Dead Floor Live
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments
0 - Self Weight (PLF)0 to 8' 1"N/A 10.4 --
1 - Uniform (PSF)0 to 8' 1" (Front)13'15.0 40.0 Floor - Upper Level
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 9/22/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Flush Pantry (H)
2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL
ForteWEB Software Operator Job Notes 11/6/2021 3:46:35 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
File Name: 17932 Exeter Circle, Lakeville, MN
Topaz - Payton XL
17932 Exeter Circle, Lakeville, MN
11/6/21; #25165
Page 17 / 26
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)3317 @ 3 1/2"4725 (1.50")Passed (70%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)2287 @ 1' 3 3/8"9878 Passed (23%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)5286 @ 3' 5 3/4"18346 Passed (29%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.038 @ 3' 5 3/4"0.159 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.070 @ 3' 5 3/4"0.319 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/480) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
• ¹ See Connector grid below for additional information and/or requirements.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Hanger on 11 7/8" LSL beam 3.50"Hanger¹1.50"1668 626 1948 4242 See note ¹
2 - Trimmer - SPF 5.50"5.50"1.50"1692 634 1972 4298 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)6' 9" o/c
Bottom Edge (Lu)6' 9" o/c
Connector: Simpson Strong-Tie
Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories
1 - Face Mount Hanger HHUS48 3.00"N/A 22-10d 8-10d
•Refer to manufacturer notes and instructions for proper installation and use of all connectors.
Dead Floor Live Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)3 1/2" to 7'N/A 13.0 ----
1 - Uniform (PSF)0 to 7' (Front)4' 6"15.0 40.0 -Floor - Upper Level
2 - Uniform (PLF)0 to 7' (Front)N/A 80.0 --Wall - Upper Level
3 - Uniform (PSF)0 to 7' (Front)1'20.0 -35.0 Snow - Porch
4 - Uniform (PSF)0 to 7' (Front)15'20.0 -35.0 Snow - Main
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 9/22/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Flush Foyer (H)
2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL
ForteWEB Software Operator Job Notes 11/6/2021 3:46:35 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
File Name: 17932 Exeter Circle, Lakeville, MN
Topaz - Payton XL
17932 Exeter Circle, Lakeville, MN
11/6/21; #25165
Page 18 / 26
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)9447 @ 1' 2 3/4"13956 (5.50")Passed (68%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)7904 @ 2' 5 3/8"9878 Passed (80%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)17692 @ 3' 6"18346 Passed (96%)1.15 1.0 D + 1.0 S (Alt Spans)
Live Load Defl. (in)0.251 @ 6' 2 7/8"0.287 Passed (L/550)--1.0 D + 1.0 S (Alt Spans)
Total Load Defl. (in)0.459 @ 6' 3 5/16"0.574 Passed (L/300)--1.0 D + 1.0 S (Alt Spans)
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/480) and TL (L/240).
•Overhang deflection criteria: LL (2L/480) and TL (2L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
• ¹ See Connector grid below for additional information and/or requirements.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Column - SPF 5.50"5.50"3.72"4219 931 5229 10379 Blocking
2 - Hanger on 11 7/8" LSL beam 3.50"Hanger¹1.50"1049 597 1079 2725 See note ¹
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)2' 7" o/c
Bottom Edge (Lu)12' 9" o/c
Connector: Simpson Strong-Tie
Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories
2 - Face Mount Hanger LUS414 2.00"N/A 10-16d 6-16d
•Refer to manufacturer notes and instructions for proper installation and use of all connectors.
Dead Floor Live Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)0 to 12' 8 1/2"N/A 13.0 ----
1 - Uniform (PSF)0 to 3' 6" (Front)1'15.0 40.0 -Floor - Upper Level
2 - Uniform (PSF)3' 6" to 13' (Front)2'15.0 40.0 -Floor - Upper Level
3 - Uniform (PLF)0 to 3' 6" (Front)N/A 80.0 --Wall - Upper Level
4 - Uniform (PSF)0 to 3' 6" (Front)8' 6"20.0 -35.0 Snow - Main
5 - Uniform (PSF)0 to 3' 6" (Front)1'20.0 -35.0 Snow - Porch
6 - Point (lb)3' 6" (Front)N/A 1668 626 1948
Linked from: Flush
Foyer (H), Support
1
7 - Point (lb)3' 6" (Front)N/A 2152 -3185 Linked from: GT3,
Support 2
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Flush Foyer (V)
2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL
ForteWEB Software Operator Job Notes 11/6/2021 3:46:35 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
File Name: 17932 Exeter Circle, Lakeville, MN
Topaz - Payton XL
17932 Exeter Circle, Lakeville, MN
11/6/21; #25165
Page 19 / 26
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 9/22/21.
Weyerhaeuser Notes
ForteWEB Software Operator Job Notes 11/6/2021 3:46:35 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
File Name: 17932 Exeter Circle, Lakeville, MN
Topaz - Payton XL
17932 Exeter Circle, Lakeville, MN
11/6/21; #25165
Page 20 / 26
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)4118 @ 1 1/2"7613 (3.00")Passed (54%)--1.0 D + 1.0 L (All Spans)
Shear (lbs)2557 @ 1' 1/2"6872 Passed (37%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)4204 @ 2' 9"10422 Passed (40%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.049 @ 2' 9"0.175 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.075 @ 2' 9"0.262 Passed (L/839)--1.0 D + 1.0 L (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Trimmer - SPF 3.00"3.00"1.62"1430 2688 4118 None
2 - Trimmer - SPF 3.00"3.00"1.62"1430 2688 4118 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)5' 6" o/c
Bottom Edge (Lu)5' 6" o/c
Dead Floor Live
Vertical Loads Location Tributary Width (0.90)(1.00)Comments
0 - Self Weight (PLF)0 to 5' 6"N/A 10.4 --
1 - Uniform (PSF)0 to 5' 6"7' 6"15.0 40.0 Floor - Main Level
2 - Uniform (PLF)0 to 5' 6"N/A 90.0 -Wall - Main Level
3 - Uniform (PSF)0 to 1'9' 6"15.0 40.0 Floor - Upper Level
4 - Uniform (PSF)4' 6" to 5' 6"9' 6"15.0 40.0 Floor - Upper Level
5 - Uniform (PLF)0 to 1'N/A 80.0 -Wall - Upper Level
6 - Uniform (PLF)4' 6" to 5' 6"N/A 80.0 -Wall - Upper Level
7 - Uniform (PSF)0 to 5' 6"7'10.0 40.0 Floor - Deck
8 - Point (lb)1'N/A 430 713
Linked from:
Kitchen Window,
Support 1
9 - Point (lb)4' 6"N/A 430 713
Linked from:
Kitchen Window,
Support 2
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 9/22/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Lower Level, Bedroom Window
2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL
ForteWEB Software Operator Job Notes 11/6/2021 3:46:35 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
File Name: 17932 Exeter Circle, Lakeville, MN
Topaz - Payton XL
17932 Exeter Circle, Lakeville, MN
11/6/21; #25165
Page 21 / 26
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)6794 @ 1 1/2"7613 (3.00")Passed (89%)--1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (lbs)2704 @ 1' 1/2"6872 Passed (39%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)4943 @ 3' 1/2"10422 Passed (47%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.072 @ 3' 2 1/2"0.208 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.113 @ 3' 2 1/4"0.313 Passed (L/661)--1.0 D + 1.0 L (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Trimmer - SPF 3.00"3.00"2.68"2894 3145 2055 8094 None
2 - Trimmer - SPF 3.00"3.00"1.50"1058 2020 121 3199 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)6' 6" o/c
Bottom Edge (Lu)6' 6" o/c
Dead Floor Live Snow
Vertical Loads Location Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)0 to 6' 6"N/A 10.4 ----
1 - Uniform (PSF)0 to 6' 6"8'15.0 40.0 -Floor - Main Level
2 - Uniform (PLF)0 to 6' 6"N/A 90.0 --Wall - Main Level
3 - Uniform (PSF)0 to 6' 6"7'10.0 40.0 -Floor - Deck
4 - Point (lb)6"N/A 1815 1105 1913
Linked from: Dining
Room Patio Door,
Support 1
5 - Uniform (PSF)0 to 6"8'15.0 40.0 -Floor - Upper
6 - Uniform (PLF)0 to 6"N/A 80.0 --Wall - Upper
7 - Uniform (PSF)0 to 6"15'20.0 -35.0 Snow - Main
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 9/22/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Lower Level, Family Room Patio Door
2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL
ForteWEB Software Operator Job Notes 11/6/2021 3:46:35 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
File Name: 17932 Exeter Circle, Lakeville, MN
Topaz - Payton XL
17932 Exeter Circle, Lakeville, MN
11/6/21; #25165
Page 22 / 26
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)8754 @ 1 1/2"11419 (3.00")Passed (77%)--1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (lbs)6951 @ 1' 1/2"9476 Passed (73%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)16160 @ 4' 1 7/8"17662 Passed (91%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.200 @ 4' 2 1/2"0.275 Passed (L/496)--1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)0.343 @ 4' 2 7/16"0.412 Passed (L/288)--1.0 D + 0.75 L + 0.75 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Trimmer - SPF 3.00"3.00"2.30"3663 4248 2540 10451 None
2 - Trimmer - SPF 3.00"3.00"2.03"3201 4154 1863 9218 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)8' 6" o/c
Bottom Edge (Lu)8' 6" o/c
Dead Floor Live Snow
Vertical Loads Location Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)0 to 8' 6"N/A 14.5 ----
1 - Uniform (PSF)0 to 8' 6"8' 6"15.0 40.0 -Floor - Main Level
2 - Uniform (PSF)0 to 8' 6"1'90.0 --Wall - Main Level
3 - Uniform (PSF)0 to 8' 6"7'10.0 40.0 -Floor - Deck
4 - Point (lb)2' 3"N/A 2513 1566 2799
Linked from: Great
Room Window,
Support 2
5 - Point (lb)6'N/A 1783 1566 1604
Linked from: Great
Room Window,
Support 3
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 9/22/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Lower Level, Family Room End Window
3 piece(s) 1 3/4" x 9 1/2" 2.0E Microllam® LVL
ForteWEB Software Operator Job Notes 11/6/2021 3:46:35 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
File Name: 17932 Exeter Circle, Lakeville, MN
Topaz - Payton XL
17932 Exeter Circle, Lakeville, MN
11/6/21; #25165
Page 23 / 26
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)1858 @ 0 1913 (1.50")Passed (97%)--1.0 D + 1.0 L (All Spans)
Shear (lbs)990 @ 10 3/4"2498 Passed (40%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)1781 @ 1' 11"3431 Passed (52%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.012 @ 1' 11"0.128 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.017 @ 1' 11"0.192 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Trimmer - SPF 1.50"1.50"1.50"517 1342 1859 None
2 - Trimmer - SPF 1.50"1.50"1.50"517 1342 1859 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)3' 10" o/c
Bottom Edge (Lu)3' 10" o/c
Dead Floor Live
Vertical Loads Location Tributary Width (0.90)(1.00)Comments
0 - Self Weight (PLF)0 to 3' 10"N/A 7.0 --
1 - Uniform (PSF)0 to 3' 10"17' 6"15.0 40.0 Floor - Main Level
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 9/22/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Lower Level, Mechanical Room Door
2 piece(s) 2 x 10 SPF No.1/No.2
ForteWEB Software Operator Job Notes 11/6/2021 3:46:35 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
File Name: 17932 Exeter Circle, Lakeville, MN
Topaz - Payton XL
17932 Exeter Circle, Lakeville, MN
11/6/21; #25165
Page 24 / 26
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)2918 @ 2' 9"3806 (1.50")Passed (77%)--1.0 D + 1.0 L (All Spans)
Shear (lbs)808 @ 1' 10"6872 Passed (12%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)1347 @ 1' 8 11/16"10422 Passed (13%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.008 @ 1' 5 3/16"0.092 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.011 @ 1' 5 3/16"0.138 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Trimmer - SPF 1.50"1.50"1.50"441 1120 1561 None
2 - Trimmer - SPF 1.50"1.50"1.50"843 2075 2918 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)2' 9" o/c
Bottom Edge (Lu)2' 9" o/c
Dead Floor Live
Vertical Loads Location Tributary Width (0.90)(1.00)Comments
0 - Self Weight (PLF)0 to 2' 9"N/A 10.4 --
1 - Uniform (PSF)0 to 2' 9"16' 3"15.0 40.0 Floor - Main Level
2 - Uniform (PSF)2' 3" to 2' 9"1'90.0 -Wall - Main Level
3 - Uniform (PSF)2' 3" to 2' 9"16' 3"15.0 40.0 Floor - Upper Level
4 - Point (lb)2' 3"N/A 418 1083
Linked from:
Mudroom Kitchen
Opening , Support 2
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 9/22/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Lower Level, Bathroom Door
2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL
ForteWEB Software Operator Job Notes 11/6/2021 3:46:35 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
File Name: 17932 Exeter Circle, Lakeville, MN
Topaz - Payton XL
17932 Exeter Circle, Lakeville, MN
11/6/21; #25165
Page 25 / 26
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)1239 @ 0 1913 (1.50")Passed (65%)--1.0 D + 1.0 L (All Spans)
Shear (lbs)432 @ 10 3/4"2498 Passed (17%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)852 @ 1' 4 1/2"3431 Passed (25%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.003 @ 1' 4 1/2"0.092 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.004 @ 1' 4 1/2"0.138 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Trimmer - SPF 1.50"1.50"1.50"345 894 1239 None
2 - Trimmer - SPF 1.50"1.50"1.50"345 894 1239 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)2' 9" o/c
Bottom Edge (Lu)2' 9" o/c
Dead Floor Live
Vertical Loads Location Tributary Width (0.90)(1.00)Comments
0 - Self Weight (PLF)0 to 2' 9"N/A 7.0 --
1 - Uniform (PSF)0 to 2' 9"16' 3"15.0 40.0 Floor - Main Level
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 9/22/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Lower Level, Bedroom Closet Door
2 piece(s) 2 x 10 SPF No.1/No.2
ForteWEB Software Operator Job Notes 11/6/2021 3:46:35 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
File Name: 17932 Exeter Circle, Lakeville, MN
Topaz - Payton XL
17932 Exeter Circle, Lakeville, MN
11/6/21; #25165
Page 26 / 26