Loading...
HomeMy WebLinkAboutLA198605 - 17924 Evershed Way Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: 20195 Holyoke Avenue, Lakeville, MN 55044 952-985-4400  952-985-4499 fax www.lakevillemn.gov Sewer & Water Tie Card Address:________________________________________ Contractor:______________________________________ Permit Number:__________________________________ Final Date:________________ Street Drain-Tile:______ Size of Water Service: 1” Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME OF SEWER & WATER INSPECTION LOT 1, BLOCK 2, KNOB HILL 3RD ADDITION*ALL DOOR & WINDOW HEADERSTO BE S.P.F. #2 OR BETTERwritten consent of Planco MN, Inc. modified or used in any redesign without the priormay not be assigned or copied, and may not bemay not be re-used for any additional structures,structure. Planco MN reserves all rights. These planslicense is granted to use these plans to build oneCopyright for these drawings is owned by Planco MN,Planco MN, Inc.cKNOB HILL MODEL #3#21-083SMA16202117924 EVERSHED WAY, LAKEVILLE STONE COTTAGE CONSTRUCTION, INC. FRONT ELEVATION 1/4" = 1'-0" 9x7 OVH. DR.8128126.125128/126.12512VINYLB & BVINYLB & BVINYLB & BVINYLB & B4" TRIM4" TRIMSTONE CAPWRAPSTONE 24"4'-6"1'-6"WOOD PORCHSTONEON JOGWRAPSTONE 24"TOTAL2nd FLR.1st FLR.1,095 SQ. FT.1,123 SQ. FT.2,218 SQ. FT.8'-4" POURED FOUNDATION9' CEILING @ FIRST FLOOR4" VINYL SIDINGSTONE AS SHOWNFRONT ONLYGRIDS IN WDWS.FRONT & SIDESALL SIDESVINYL B & BFRONT ONLY12x12 BOXED COL.FLOWERBOX8" BOXED BEAMVINYLSIDING4" TRIMFRONT ONLYTOTALBSM'T696 SQ. FT.2,914 SQ. FT.16x7 OVH. DR.VINYLSIDING LEFT ELEVATION 1/8" = 1'-0" VINYLCORNERSSIDINGVINYL 8128/12126126.1252'-0"2'-0" RIGHT ELEVATION 1/8" = 1'-0" SIDINGVINYL VINYLCORNERSSIDINGVINYL 8121261'-0"2'-0"126.125 REAR ELEVATION 1/8" = 1'-0" SIDINGVINYL VINYLCORNERSSIDINGVINYL 8121261'-6"14' DECK LEDGERSecure door closed until deck isconstructed with a separate permit.Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode12/29/2021dmathews Planco MN, Inc.C#21-083SMA262021 BASEMENT PLAN 1/4" = 1'-0" UNEXCAVATED UP15 R2868WHFURNF.D.92% MECH/STORAGE *UNFINISHED11'-0"36'-0"15'-0"14'-0"7'-0"48'-0" 22'-6"25'-6" 4'-0"21'-6"20'-6"2'-0"47'-0"30'-0"17'-0"11'-0"19'-0"8'-0"14'-0"11'-0"48'-0"8'-0"10'-8"7'-4"18'-0"6'-6" 3'-8"3'-8"7'-6"30"x30"x12"CONC. PAD FTG.18'-6"8'-4" POURED FOUNDATIONWALLEDGEWALLEDGE5'-8"15'-10"FTG. SIZE BY OTHERSTRT. 4x4 CURB2x4 - 16" O.C.FTG. SIZE BY OTHERSTRT. 4x4 CURB2x4 - 16" O.C.FTG. SIZE BY OTHERSTRT. 4x6 CURB2x6 - 16" O.C.11 7/8" I JTS. 19.2" O.C. 11 7/8" LSL JOISTS 11 7/8" I JTS. 19.2" O.C.6x6 POSTRADONVENT6" CANT.2" LEDGE”),1,6+('64)7 (;&/8'(667$,56 6'-0"x6'-10" P.D.2-9 1/2" LSL7'-0"7'-0"(2) TRT. 6x6 POSTON 12x16 PIER FTG.24x24 FROST FTG.9"7'-6"8'-9"TREATED 2x8 16" O.C.TRT. 2-2x8 FLUSHTRT. 2-2x8 FLUSH10'-0" 10'-0" LOOKOUT LOOKOUT WALKOUTWALKOUT2868 STORAGE *UNFINISHED18'-0"1'-2"11 7/8" LSL JOISTS BEDROOM *CARPET506826683-2x106/0x5/0 SL7'-2"7'-10"SD8'-10"3'-6"30"x30"x12"CONC. PAD FTG.FTG. SIZE BY OTHERSTRT. 4x6 CURB2x6 - 16" O.C.266830"4834NO FTG.@ TOILET2-2x101 PIECE FIB.F*VINYL2-9 1/2" LSL DROPPED4'-4"5'-0"SUMPSD/CO FAMILY/REC RM *CARPET4'-0" 19'-10" 11 7/8" I JTS. 16" O.C.10"2-2x101-11 7/8" LSLFLUSH333UFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. Planco MN, Inc.C#21-083SMA362021 FIRST FLOOR PLAN 1/4" = 1'-0" 1,095 SQ. FT.9' CEILING @ FIRST FLOOR WOOD PORCH 12x12 BOXED COL.2-7 1/4" LSL4'-4"UP17 RDN15 R5'-10"GASF.P.PED 20682468DESK12" SH'S24682868FIREDOOR14'-6"11'-6"REF'G10" S.B.30"PANT.2868 C.O.PANTRY*WOOD1/2 WALLW/ WD. CAP3-9 1/2" LSL9/0x5/0 SL6'-0"x6'-10" P.D.CHASE 30682/6x2/6 AWN2-2x10WALLEDGEWALLEDGE5/0x4/0 FX TEMP2-2x10 SET 3" OFF T.O.F. 2/0x2/0 FX2-2x10 2/0x2/0 FX2-2x10 3-2x102-2x104/0x4/0 SLREF'GRECESS9x7 OVH. DR.16x7 OVH. DR.*4" CONC. FLOOR GARAGE 2-2x10 2/0x2/0 FX FOYER *WOOD*WOOD DINING *WOOD GREAT ROOM KITCHEN *WOOD MUD RM *VINYL*WOOD*WOOD*2x6 WALLS11'-0"36'-0"15'-0"14'-0"7'-0"3'-10"3'-2"7'-0"7'-0"6'-4"8'-8"48'-0" 22'-6"25'-6" 4'-0"21'-6"20'-6"2'-0" 6'-0"4'-4"4'-10"6'-4" 3'-8"2'-8"47'-0"30'-0"17'-0"11'-0"19'-0"5'-11"5'-1"9'-6"9'-6"8'-9"7'-6"9"8'-0"14'-0"4'-7"8'-8"4'-3"11'-0"7'-4"11'-2"2'-2"4'-2"4'-10"6"2-2x1048'-0"8'-0"10'-8"7'-4"18'-0"6'-2"4'-6"3'-8"3'-8"5'-10"6'-4"5'-10"3'-2"2'-8"2'-8"3'-2"1'-8"RAILRAIL2'-10"6'-2"11'-4"3'-8"3'-8"4'-0"8'-0" CAB. 4'-0"2-7 1/4" LSL6'-6"6'-0"6"7'-4"F21'-8" 18" FLR.TRUSS 19.2" O.C. 18" FLR.TRUSS 19.2" O.C. GIRDER F.T.2-2x10FLUSH2-2x10 FLUSH24" CANT.12" CANT.36'-0"4'-0"RADONVENT2x6TRUSSES24" O.C.2-9 1/2" LVLFLUSH2-2x10GYP. BD.24" SH'S24683'-0" CAB.TOP @ 6'-10"TOP @ 6'-10"4"2'-6" W.I.C. *VINYL4"4"3-2x102-11 7/8" LSL2-11 7/8" LSL17'-0"2x6MICROSD/CO*CEDAR DECKING30" RANGE W/ HOODVENT4'-0"4"10"BWPsAbove2.25583388CS-PFPFHPFH Planco MN, Inc.C#21-083SMA462021 SECOND FLOOR PLAN 1/4" = 1'-0" 1,123 SQ. FT.DN17 R5'-0" TUB & SHOWER 1 PIECE FIB.66"2468266824685/0x6/0 FX TEMP 5'-2"7'-8"5'-8"WD2468PKT.2668206826685068LIN.6/0x4/6 SL2-2x102/6x2/6 FX2-2x10*CARPET MASTER BEDROOM *CARPET BEDROOM #2 BEDROOM #3 *CARPET W.I.C. *CARPET W.I.C. *CARPET2-2x107/6x5/0 SL3-2x106/0x5/0 SL36'-0"7'-0"14'-0"15'-0"7'-0"7'-0"8'-8"6'-4"12'-4"3'-0"7'-0"1'-10"3'-6" 42'-0" 38'-0"4'-0" 12'-4"5'-8"7'-4"12'-8"WALLEDGEWALLEDGE3-9 1/2" LSL TOP @ 8' OFF LNDG.36'-0"17'-6"18'-6"12'-0"5'-6"6'-0"6'-0"2'-6"3'-0"1'-0" 15'-0" 26'-0" 22'-0"4'-0" 9'-0"17'-0" 3'-8"3'-8"12'-8" 10" 4'-2"4'-4"6'-8"6'-6"4'-10"FF*VINYL*VINYLSD/COSDSD2x6GIRDERGIRDERACCESS ATTIC 3'-8"3'-8"1/2 WALLW/ WD. CAP10"TRUSSES 24" O.C.TRUSSES24" O.C.TRUSSES24" O.C.RADONVENT2x660342468 C.O.LT2868PKT.2468246824x24LIN.102" 5'-3"6'-5"3'-8" 2-2x10 2/0x2/6 AWN 2-2x102/6x4/0 SH5'-3"1'-9"*C.T.1/2 WALLW/ WD. CAPFIB. BASEC.T. WALLS2-2x10 2/0x2/6 AWN 6'-8"2'-6"2'-0"2'-0"*BOX VAULT27"BASECOUNTERONLY*C.T.7'-6" ROOF PLAN 1/8" = 1'-0" 2'-0"2'-0"1'-6"1'-6"1'-0"GIRDERGIRDER1'-0"1'-6"2'-0"1'-0"812812812812812812126126.125Temper ifglass within60" of floor.FAN222223322222-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ). Planco MN, Inc.C#21-083SMA562021 CROSS SECTION 3/8" = 1'-0" SHEATHINGR-21 INSUL.9'-11 8"3 1/2" CONC. FLOOR1/2" GYP. BD.VB11 7/8" LSL JOISTS “TRT. 4x6 CURB2X6- 16" O.C.3/4" T & G FLOOR5/8" GYP. BD.2x6- 16" O.C.GRADE22'-0"2x6- 16" O.C.VB1/2" GYP. BD.R-21 INSUL.5/8" GYP. BD.W/ V.B.3/4" T & G FLOORR-21 INSUL.1/2" GYP. BD.VB2x6- 16" O.C.2x6- 16" O.C.VB1/2" GYP. BD.R-21 INSUL.8'-11 8"18" FLOOR TRUSSES @ 19.2"O.C.SIDINGSHEATHING15 RISERSTRT. 4x6 CURB2X6- 16" O.C.17 RISERS FASCIAALUM. ALUM.SOFFITVENTED1/2" SHTG.15# FELTSHINGLES2'-0"ENERGY HEEL612ROOF VENTS @ 1/300 ATTIC50% ROOF 50% SOFFIT(DESIGNED BY MFR)TRUSSES @ 24" O.C.R-49 INSUL.2'-0"SIDING6'-8" MIN. HDRM1x8 RISERS5/4x11 TREADS3- 2x12 STRINGERSTAIR NOTES:10" RUFF CUT TREADS16'-0"ALUM.ALUM. FASCIASOFFITVENTED2'-0"TRT. 6x6 POST2-7 1/4" LSL12x12 BOXEDCOLUMN6.125126'-0"6'-6"73 8"PER CODEWALL W/ REBAR8'-4" POUREDSILL PLATE1-2x6 TREATEDDRAIN TILE R-20 SPRAY FOAMPROOFINGWATERR-10 W/ <2.6 ACHINSUL.R-20 SPRAY FOAMR-20 SPRAY FOAMR-20 SPRAY FOAMMIN. R-38@ CANT.10'-8"71 2"TRT. 4x4 CURB2X4- 16" O.C.1'-21 4"11'-8"GIRDER11 7/8" I JST. @ 19.2" O.C. FOYER GREAT ROOM BEDROOM #2 BEDROOM #3 8" BOXEDBEAMFOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECSFOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECS5/8" GYP. BD.POURED WALLGRADE2" FOAM758"2" FOAM W/“%(9(/512"4'-0"R-21 INSUL.1/2" GYP. BD.VB2x6- 16" O.C.TRT. 6x6 POST24x24 PADFOOTING12x16 PIERFOOTINGTRT. 2-2x8TRT. 2x8 @ 16" O.C.CEDAR DECKINGFLOOR SYSTEMROOFTRUSSPVC T-FITTINGTO SUPPORTVENT PIPEMIN. 4" OF GASPERMEABLE MATERIAL3 1/2" CONC. SLAB4" PVC VENT PIPESUPPORTSTRAPPINGFLASHINGEXHAUST 10' FROM OPNGS.INTO CONDITIONED SPACESOF BUILDING12" MIN. ABOVE ROOFSEAL6 MIL POLYUNDER SLAB10' OF DRAIN TILEEACH WAY FROMT-FITTING(ROCK) RADON GAS VENT SYSTEM 3/8" = 1'-0" 36" MIN. HT. CLEAR SPACE24" DIA. AROUND VENTPROVIDE ELECTRICALBOX POWER SOURCER-4 MIN. INSUL. VENT PIPE@ UNCONDITIONED SPACE4" MIN. CLEARANCEFOR FUT. FAN Planco MN, Inc.C#21-083SMA662021 CROSS SECTION 3/8" = 1'-0" SHEATHINGSIDING1-2x6 TREATEDR-21 INSUL.9'-11 8"3 1/2" CONC. FLOOR1/2" GYP. BD.VB8'-4" POURED “WALL W/ REBARPER CODE3/4" T & G FLOORSILL PLATE5/8" GYP. BD.2x6- 16" O.C.WATERPROOFING22'-0"2x6- 16" O.C.VB1/2" GYP. BD.R-21 INSUL.5/8" GYP. BD.W/ V.B.3/4" T & G FLOORR-21 INSUL.1/2" GYP. BD.VB2x6- 16" O.C.2x6- 16" O.C.VB1/2" GYP. BD.R-21 INSUL.8'-11 8"18" FLOOR TRUSSES @ 19.2"O.C.4" CONC. FLOOR GARAGE GRADEPOURED WALL2X6- 16" O.C.SLOPE TO DOORS1'-0"612ROOF VENTS @ 1/300 ATTIC50% ROOF 50% SOFFIT(DESIGNED BY MFR)TRUSSES @ 24" O.C.R-49 INSUL.22'-0"2X4- 16" O.C.10'-31 4"R-20 SPRAY FOAMR-20 SPRAY FOAMR-20 SPRAY FOAMR-20 SPRAY FOAMDRAIN TILE R-10 W/ <2.6 ACHINSUL.1/2" GYP. BD.TRT. 4x4 CURB26'-0"(DESIGNED BY MFR)TRUSSES @ 24" O.C.17'-0" MASTER BEDROOM DINING KITCHEN 11'-8"1'-21 4"4'-0"GIRDER6.12512FOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECSFOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECS5/8" GYP. BD.11 7/8" I JST. @ 16" O.C.2'-0"1'-0"BOX VAULTFOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECSPOURED WALLGRADE2" FOAM758"2" FOAM W/“%(9(/512"4'-0"R-21 INSUL.1/2" GYP. BD.VB2x6- 16" O.C.11 7/8" LSL JOISTS BASEMENT PLAN UNEXCAVATED UP15 R2868WHFURNF.D.92% MECH/STORAGE *UNFINISHED11'-0"36'-0"15'-0"14'-0"7'-0"48'-0" 22'-6"25'-6" 4'-0"21'-6"20'-6"2'-0"47'-0"30'-0"17'-0"11'-0"19'-0"8'-0"14'-0"11'-0"48'-0"8'-0"10'-8"7'-4"18'-0"6'-6" 3'-8"3'-8"7'-6"30"x30"x12"CONC. PAD FTG.18'-6"WALLEDGEWALLEDGE5'-8"15'-10"FTG. SIZE BY OTHERSTRT. 4x4 CURB2x4 - 16" O.C.FTG. SIZE BY OTHERSTRT. 4x4 CURB2x4 - 16" O.C.FTG. SIZE BY OTHERSTRT. 4x6 CURB2x6 - 16" O.C.11 7/8" I JTS. 19.2" O.C. 11 7/8" LSL JOISTS 11 7/8" I JTS. 19.2" O.C.6x6 POSTRADONVENT6" CANT.2" LEDGE6'-0"x6'-10" P.D.3-2x107'-0"7'-0"(2) TRT. 6x6 POSTON 12x16 PIER FTG.24x24 FROST FTG.9"7'-6"8'-9"TREATED 2x8 16" O.C.TRT. 2-2x8 FLUSHTRT. 2-2x8 FLUSH10'-0" 10'-0" LOOKOUT LOOKOUT WALKOUTWALKOUT2868 STORAGE *UNFINISHED18'-0"1'-2"11 7/8" LSL JOISTS BEDROOM *CARPET506826683-2x106/0x5/0 SL7'-2"7'-10"SD8'-10"3'-6"30"x30"x12"CONC. PAD FTG.FTG. SIZE BY OTHERSTRT. 4x6 CURB2x6 - 16" O.C.266830"4834NO FTG.@ TOILET2-2x101 PIECE FIB.F*VINYL2-11 7/8" LSL DROPPED4'-4"5'-0"SUMPSD/CO FAMILY/REC RM *CARPET4'-0" 19'-10" 11 7/8" I JTS. 16" O.C.10"10'BWL 13'3'3' FIRST FLOOR PLAN WOOD PORCH 12x12 BOXED COL.2-7 1/4" LSL4'-4"UP17 RDN15 R5'-10"GASF.P.PED 20682468DESK12" SH'S24682868FIREDOOR14'-6"11'-6"REF'G10" S.B.30"PANT.2868 C.O.PANTRY*WOOD1/2 WALLW/ WD. CAP2-9 1/2" LVL9/0x5/0 SL6'-0"x6'-10" P.D.CHASE 30682/6x2/6 AWN2-2x10WALLEDGEWALLEDGE5/0x4/0 FX TEMP3-2x10SET 3" OFF T.O.F.2/0x2/0 FX2-2x10 2/0x2/0 FX2-2x10 3-2x102-2x104/0x4/0 SLREF'GRECESS9x7 OVH. DR.16x7 OVH. DR.*4" CONC. FLOOR GARAGE 2-2x10 2/0x2/0 FX FOYER *WOOD*WOOD DINING *WOOD GREAT ROOM KITCHEN *WOOD MUD RM *VINYL*WOOD*WOOD*2x6 WALLS11'-0"36'-0"15'-0"14'-0"7'-0"3'-10"3'-2"7'-0"7'-0"6'-4"8'-8"48'-0" 22'-6"25'-6" 4'-0"21'-6"20'-6"2'-0" 6'-0"4'-4"4'-10"6'-4" 3'-8"2'-8"47'-0"30'-0"17'-0"11'-0"19'-0"5'-11"5'-1"9'-6"9'-6"8'-9"7'-6"9"8'-0"14'-0"4'-7"8'-8"4'-3"11'-0"7'-4"11'-2"2'-2"4'-2"4'-10"6"2-2x1048'-0"8'-0"10'-8"7'-4"18'-0"6'-2"4'-6"3'-8"3'-8"5'-10"6'-4"5'-10"3'-2"2'-8"2'-8"3'-2"1'-8"RAILRAIL2'-10"6'-2"11'-4"3'-8"3'-8"4'-0"8'-0" CAB. 4'-0"2-7 1/4" LSL6'-6"6'-0"6"7'-4"F21'-8" 18" FLR.TRUSS 19.2" O.C. 18" FLR.TRUSS 19.2" O.C. GIRDER F.T.2-2x10FLUSH2-2x10 FLUSH24" CANT.12" CANT.36'-0"4'-0"RADONVENT2x6TRUSSES24" O.C.2-9 1/2" LSLFLUSH2-2x10GYP. BD.24" SH'S24683'-0" CAB.TOP @ 6'-10"TOP @ 6'-10"4"2'-6" W.I.C. *VINYL4"4"2-2x102-2x122-11 7/8" LSL17'-0"2x6MICROSD/CO*CEDAR DECKING30" RANGE W/ HOODVENT4'-0"4"10"47'40'BWL 2BWL 3BWL 4BWL 5SEE DETAIL 2/PF-14'4'4'3'3'SEE DETAIL 1/PF-18'8'2'-3"8'5' 36'36'BWL 6BWL 7BWL 8BWL 93'3'2'2'2'2'2'2'2'2'2'2' SECOND FLOOR PLAN DN17 R5'-0" TUB & SHOWER 1 PIECE FIB.66"2468266824685/0x6/0 FX TEMP 5'-2"7'-8"5'-8"WD2468PKT.2668206826685068LIN.6/0x4/6 SL2-2x102/6x2/6 FX2-2x10*CARPET MASTER BEDROOM *CARPET BEDROOM #2 BEDROOM #3 *CARPET W.I.C. *CARPET W.I.C. *CARPET2-2x107/6x5/0 SL2-2x106/0x5/0 SL36'-0"7'-0"14'-0"15'-0"7'-0"7'-0"8'-8"6'-4"12'-4"3'-0"7'-0"1'-10"3'-6" 42'-0"38'-0"4'-0"12'-4"5'-8"7'-4"12'-8"WALLEDGEWALLEDGE2-9 1/2" LSL TOP @ 8' OFF LNDG.36'-0"17'-6"18'-6"12'-0"5'-6"6'-0"6'-0"2'-6"3'-0"1'-0" 15'-0" 26'-0" 22'-0"4'-0" 9'-0"17'-0" 3'-8"3'-8"12'-8" 10" 4'-2"4'-4"6'-8"6'-6"4'-10"FF*VINYL*VINYLSD/COSDSD2x6GIRDERGIRDERACCESS ATTIC 3'-8"3'-8"1/2 WALLW/ WD. CAP10"TRUSSES 24" O.C.TRUSSES24" O.C.TRUSSES24" O.C.RADONVENT2x660342468 C.O.LT2868PKT.2468246824x24LIN.102" 5'-3"6'-5"3'-8" 2-2x10 2/0x2/6 AWN 2-2x102/6x4/0 SH5'-3"1'-9"*C.T.1/2 WALLW/ WD. CAPFIB. BASEC.T. WALLS2-2x10 2/0x2/6 AWN 6'-8"2'-6"2'-0"2'-0"*BOX VAULT27"BASECOUNTERONLY*C.T.7'-6" Voigt & Associates, Inc.C-1Structural Engineering Services 4635 Nicols Road, Suite 204Eagan, MN 55122MethodCS-WSPWind speed 115Exposure C BWL 1 2 3 4 5 6 7 8 9Spacing - ft 10 40 40 47 47 36 36 36 36Level 3 2 2 2 2 1 1 1 1Length req'd- ft 5 11.5 11.5 13.3 13.3 5.4 5.4 5.4 5.4per Table R602.10.3(1)Adjustments:Exposure 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3Eave to ridge Height 0.94 0.91 0.91 0.91 0.91 0.82 0.82 0.82 0.82Wall Height 0.95 0.95 0.95 0.95 0.95 0.9 0.9 0.9 0.9# of BWL 1 1 1 1 1 1 1 1 14" Gyp WB w.block joints1 1 1 1 1 1 1 1 1Adjusted Length 5.8 12.9 12.9 14.9 14.9 5.2 5.2 5.2 5.2Knob Hill Model #317924 Evershed Way, Lakeville, MN Sheet Stone Cottage HVAC Load Calculations for Stone Cottage 17924 Evershed Way Lakeville,mn Prepared By: Randy Andrews Lofgren Heating 5708 Upper 147th Street West Apple Vallley, MN 55124 Thursday, November 18, 2021 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 2 Project Report General Project Information Project Title:Stone Cottage Project Date:Thursday, November 18, 2021 Client Name:Stone Cottage Client Address:17924 Evershed Way Client City:Lakeville,mn Company Name:Lofgren Heating Company Representative:Randy Andrews Company Address:5708 Upper 147th Street West Company City:Apple Vallley, MN 55124 Company E-Mail Address:rrandrews@lofgrenheating-ac.com Design Data Reference City:Minneapolis, Minnesota Building Orientation:Front door faces West Daily Temperature Range:Medium Latitude:44 Degrees Elevation:834 ft. Altitude Factor:0.970 Elevation Sensible Adj. Factor:1.000 Elevation Total Adj. Factor:1.000 Elevation Heating Adj. Factor:1.000 Elevation Heating Adj. Factor:1.000 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter:-15 -15.33 80%n/a 72 n/a Summer:88 72 47%50%75 29 Check Figures Total Building Supply CFM:1,326 CFM Per Square ft.:0.400 Square ft. of Room Area:3,313 Square ft. Per Ton:1,128 Volume (ft³) of Cond. Space:29,817 Building Loads Total Heating Required Including Ventilation Air:51,004 Btuh 51.004 MBH Total Sensible Gain:28,650 Btuh 81 % Total Latent Gain:6,585 Btuh 19 % Total Cooling Required Including Ventilation Air:35,235 Btuh 2.94 Tons (Based On Sensible + Latent) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\17924 EVERSHED LAKEVILLE 11182021.rhv Thursday, November 18, 2021, 9:33 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 3 Miscellaneous Report System 1 Whole House Input Data Outdoor Dry Bulb Outdoor Wet Bulb Outdoor Rel.Hum Indoor Rel.Hum Indoor Dry Bulb Grains Difference Winter:-15 -15.33 80%n/a 72 n/a Summer:88 72 47%50%75 29.27 Duct Sizing Inputs Main Trunk Runouts Calculate:Yes Yes Use Schedule:No No Roughness Factor:0.00300 0.01000 Pressure Drop:0.1000 in.wg./100 ft.0.1000 in.wg./100 ft. Minimum Velocity:650 ft./min 450 ft./min Maximum Velocity:900 ft./min 750 ft./min Minimum Height:8 in.6 in. Maximum Height:10 in.6 in. Outside Air Data Winter Summer Infiltration Specified:0.250 AC/hr 0.130 AC/hr 93 CFM 48 CFM Infiltration Actual:0.250 AC/hr 0.130 AC/hr Above Grade Volume:Cu.ft.Cu.ft.X 22,296 X 22,296 5,574 Cu.ft./hr 2,898 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration:93 CFM 48 CFM Total Building Ventilation:140 CFM 70 CFM ---System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 13.87 = (1.10 X 0.970 X 13.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 19.31 = (0.68 X 0.970 X 29.27 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 92.85 = (1.10 X 0.970 X 87.00 Winter Temp. Difference) Winter Infiltration Specified:0.250 AC/hr (93 CFM), Construction: Unknown Summer Infiltration Specified:0.130 AC/hr (48 CFM), Construction: Unknown C:\ ...\17924 EVERSHED LAKEVILLE 11182021.rhv Thursday, November 18, 2021, 9:33 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 4 Load Preview Report Scope Has AED Net Ton ft.² /Ton Area Sen Gain Lat Gain Net Gain Sen Loss Sys Htg CFM Sys Clg CFM Sys Act CFM Duct Size Building 2.94 1,128 3,313 28,650 6,585 35,235 51,004 967 1,326 1,326 System 1 Yes 2.94 1,128 3,313 28,650 6,585 35,235 51,004 967 1,326 1,326 24x10 Ventilation 340 1,352 1,692 4,550 Zone 1 3,313 28,310 5,233 33,543 46,454 967 1,326 1,326 24x10 1-Main Level 1,095 11,638 1,812 13,450 17,224 359 545 545 6--6 2-Upper Level 1,123 12,302 2,423 14,725 17,998 375 576 576 7--6 3-Lower Level 1,095 4,370 998 5,368 11,232 234 205 205 2--6 C:\ ...\17924 EVERSHED LAKEVILLE 11182021.rhv Thursday, November 18, 2021, 9:33 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 5 Duct Size Preview Room or Duct Name Minimum Velocity Maximum Velocity Rough. Factor Design L/100 Actual L/100 SP Loss Duct Velocity Duct Length Htg Flow Clg Flow Act. Flow Duct Size System 1 Supply Runouts Zone 1 1-Main Level 450 750 0 0.1 0.1 462.8 359 545 545 6--6 2-Upper Level 450 750 0 0.1 0.1 419.3 375 576 576 7--6 3-Lower Level 450 750 0 0.1 0.2 521.4 234 205 205 2--6 Other Ducts Supply Main Trunk 650 900 0 0.1 0.1 795.8 967 1,326 1,326 24x10 SummarySummarySummarySummarySummarySummarySummarySummary System 1 Heating Flow:967 Cooling Flow:1326 C:\ ...\17924 EVERSHED LAKEVILLE 11182021.rhv Thursday, November 18, 2021, 9:33 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 6 System 1 - Whole House - Adequate Exposure Diversity Test Test For Adequate Exposure Diversity Average Glass Sensible Gain Over 12 Hours 1.3 x Average Glass Gain Hourly Glass Gain Hourly Total Net GainHeat Gain, Btuh9.6% Diff. from Avg. 0 10,000 20,000 30,000 40,000 8 am 9 am 10 am 11 am 12 pm 1 pm 2 pm 3 pm 4 pm 5 pm 6 pm 7 pm AED Calculation Summary --- SYSTEM HAS ADEQUATE EXPOSURE DIVERSITY. --- System is on N, E, S, W rosette. Peak load exceeds 12-hour average load by 9.6%. AED Excursion (amount by which peak exceeds 1.3 x average): 0 Btuh Definition: A system has adequate exposure diversity if the peak-hour glass load for the entire conditioned space does not exceed the average glass load for the entire conditioned space by more than 30 percent. C:\ ...\17924 EVERSHED LAKEVILLE 11182021.rhv Thursday, November 18, 2021, 9:33 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 7 System 1 - Whole House - Psychrometric Chart ZC Zone (Room) Condition OC Outdoor Condition LC Leaving Coil Condition EC Entering Coil Condition SD Supply Duct Temperature Rise DTF Draw Through Fan Sensible Gain HRV Heat Recovery Ventilator C:\ ...\17924 EVERSHED LAKEVILLE 11182021.rhv Thursday, November 18, 2021, 9:33 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 8 Total Building Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain 4A-1a-o: Glazing-Double pane low-e (e = 0.20 or less), operable window, e=0.20 on surface 2, wood with metal clad frame, u-value 0.32, SHGC 0.33 473 13,168 0 14,909 14,909 11N: Door-Metal - Polystyrene Core 42 1,278 0 352 352 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs 2581 14,595 0 2,231 2,231 15B0-10sf-10: Wall-Basement, , R-10 board insulation to floor, no interior finish, 10' floor depth 1044 4,451 0 0 0 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation 1123 1,954 0 1,078 1,078 21A-24: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 24' wide 1095 2,382 0 0 0 Subtotals for structure:37,828 0 18,570 18,570 People:9 1,800 2,070 3,870 Equipment:2,500 7,000 9,500 Lighting:0 0 0 Ductwork:0 0 0 0 Infiltration: Winter CFM: 93, Summer CFM: 48 8,626 933 670 1,603 Ventilation: Winter CFM: 140, Summer CFM: 70 4,550 1,352 340 1,692 Total Building Load Totals:51,004 6,585 28,650 35,235 Check Figures Total Building Supply CFM:1,326 CFM Per Square ft.:0.400 Square ft. of Room Area:3,313 Square ft. Per Ton:1,128 Volume (ft³) of Cond. Space:29,817 Building Loads Total Heating Required Including Ventilation Air:51,004 Btuh 51.004 MBH Total Sensible Gain:28,650 Btuh 81 % Total Latent Gain:6,585 Btuh 19 % Total Cooling Required Including Ventilation Air:35,235 Btuh 2.94 Tons (Based On Sensible + Latent) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\17924 EVERSHED LAKEVILLE 11182021.rhv Thursday, November 18, 2021, 9:33 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 9 Building Pie Chart Building Loss 51,004 Btuh Floor 5%Roof 4% Wall 37% Glass 26% Door 3% Infiltration 17% Ventilation 9% Building Gain 35,235 Btuh Roof 3%Wall 6% Glass 42% Door 1% People 11% Equipment 27% Infiltration 5%Ventilation 5% C:\ ...\17924 EVERSHED LAKEVILLE 11182021.rhv Thursday, November 18, 2021, 9:33 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 10 Building Bar Graph Building Loss 51,004 Btuh 0 5,000 10,000 15,000 20,000 Floor 5%Wall 37%Door 3%Ventilation 9% Roof 4%Glass 26%Infiltration 17% Building Gain 35,235 Btuh 0 5,000 10,000 15,000 Roof 3%Glass 42%People 11%Infiltration 5% Wall 6%Door 1%Equipment 27%Ventilation 5% C:\ ...\17924 EVERSHED LAKEVILLE 11182021.rhv Thursday, November 18, 2021, 9:33 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 11 System 1 Whole House Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain 4A-1a-o: Glazing-Double pane low-e (e = 0.20 or less), operable window, e=0.20 on surface 2, wood with metal clad frame, u-value 0.32, SHGC 0.33 473 13,168 0 14,909 14,909 11N: Door-Metal - Polystyrene Core 42 1,278 0 352 352 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs 2581 14,595 0 2,231 2,231 15B0-10sf-10: Wall-Basement, , R-10 board insulation to floor, no interior finish, 10' floor depth 1044 4,451 0 0 0 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation 1123 1,954 0 1,078 1,078 21A-24: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 24' wide 1095 2,382 0 0 0 Subtotals for structure:37,828 0 18,570 18,570 People:9 1,800 2,070 3,870 Equipment:2,500 7,000 9,500 Lighting:0 0 0 Ductwork:0 0 0 0 Infiltration: Winter CFM: 93, Summer CFM: 48 8,626 933 670 1,603 Ventilation: Winter CFM: 140, Summer CFM: 70 4,550 1,352 340 1,692 System 1 Whole House Load Totals:51,004 6,585 28,650 35,235 Check Figures Supply CFM:1,326 CFM Per Square ft.:0.400 Square ft. of Room Area:3,313 Square ft. Per Ton:1,128 Volume (ft³) of Cond. Space:29,817 System Loads Total Heating Required Including Ventilation Air:51,004 Btuh 51.004 MBH Total Sensible Gain:28,650 Btuh 81 % Total Latent Gain:6,585 Btuh 19 % Total Cooling Required Including Ventilation Air:35,235 Btuh 2.94 Tons (Based On Sensible + Latent) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\17924 EVERSHED LAKEVILLE 11182021.rhv Thursday, November 18, 2021, 9:33 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 12 System 1 Whole House Pie Chart System 1 Whole House Loss 51,004 Btuh Floor 5%Roof 4% Wall 37% Glass 26% Door 3% Infiltration 17% Ventilation 9% System 1 Whole House Gain 35,235 Btuh Roof 3%Wall 6% Glass 42% Door 1% People 11% Equipment 27% Infiltration 5%Ventilation 5% C:\ ...\17924 EVERSHED LAKEVILLE 11182021.rhv Thursday, November 18, 2021, 9:33 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 13 System 1 Whole House Bar Graph System 1 Whole House Loss 51,004 Btuh 0 5,000 10,000 15,000 20,000 Floor 5%Wall 37%Door 3%Ventilation 9% Roof 4%Glass 26%Infiltration 17% System 1 Whole House Gain 35,235 Btuh 0 5,000 10,000 15,000 Roof 3%Glass 42%People 11%Infiltration 5% Wall 6%Door 1%Equipment 27%Ventilation 5% C:\ ...\17924 EVERSHED LAKEVILLE 11182021.rhv Thursday, November 18, 2021, 9:33 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 14 System 1, Zone 1 Summary Loads (Average Load Procedure for Rooms) Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain 4A-1a-o: Glazing-Double pane low-e (e = 0.20 or less), operable window, e=0.20 on surface 2, wood with metal clad frame, u-value 0.32, SHGC 0.33 473 13,168 0 14,909 14,909 11N: Door-Metal - Polystyrene Core 42 1,278 0 352 352 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs 2581 14,595 0 2,231 2,231 15B0-10sf-10: Wall-Basement, , R-10 board insulation to floor, no interior finish, 10' floor depth 1044 4,451 0 0 0 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation 1123 1,954 0 1,078 1,078 21A-24: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 24' wide 1095 2,382 0 0 0 Subtotals for structure:37,828 0 18,570 18,570 People:9 1,800 2,070 3,870 Equipment:2,500 7,000 9,500 Lighting:0 0 0 Ductwork:0 0 0 0 Infiltration: Winter CFM: 93, Summer CFM: 48 8,626 933 670 1,603 System 1, Zone 1 Load Totals:46,454 5,233 28,310 33,543 Check Figures Supply CFM:1,326 CFM Per Square ft.:0.400 Square ft. of Room Area:3,313 Square ft. Per Ton:1,185 Volume (ft³) of Cond. Space:29,817 Zone Loads Total Heating Required:46,454 Btuh 46.454 MBH Total Sensible Gain:28,310 Btuh 84 % Total Latent Gain:5,233 Btuh 16 % Total Cooling Required:33,543 Btuh 2.80 Tons (Based On Sensible + Latent) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\17924 EVERSHED LAKEVILLE 11182021.rhv Thursday, November 18, 2021, 9:33 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 15 System 1, Zone 1 Pie Chart System 1, Zone 1 Loss 46,454 Btuh Floor 5%Roof 4% Wall 41% Glass 28% Door 3% Infiltration 19% System 1, Zone 1 Gain 33,543 Btuh Roof 3%Wall 7% Glass 44% Door 1% People 12% Equipment 28% Infiltration 5% C:\ ...\17924 EVERSHED LAKEVILLE 11182021.rhv Thursday, November 18, 2021, 9:33 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 16 System 1, Zone 1 Bar Graph System 1, Zone 1 Loss 46,454 Btuh 0 5,000 10,000 15,000 20,000 Floor 5%Wall 41%Door 3% Roof 4%Glass 28%Infiltration 19% System 1, Zone 1 Gain 33,543 Btuh 0 5,000 10,000 15,000 Roof 3%Glass 44%People 12%Infiltration 5% Wall 7%Door 1%Equipment 28% C:\ ...\17924 EVERSHED LAKEVILLE 11182021.rhv Thursday, November 18, 2021, 9:33 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 17 Detailed Room Loads - Room 1 - Main Level (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:1,095.0 ft.System Number:1 Room Width:1.0 ft.Zone Number:1 Area:1,095.0 sq.ft.Supply Air:545 CFM Ceiling Height:9.0 ft.Supply Air Changes:3.3 AC/hr Volume:9,855.0 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:6 Actual Winter Vent.:52 CFM Runout Air:91 CFM Percent of Supply.:10 % Runout Duct Size:6 in.Actual Summer Vent.:29 CFM Runout Air Velocity:463 ft./min.Percent of Supply:5 % Runout Air Velocity:463 ft./min.Actual Winter Infil.:41 CFM Actual Loss:0.134 in.wg./100 ft.Actual Summer Infil.:21 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain S -Wall-12F-0sw 40 X 9 356 0.065 5.7 2,013 0.9 0 308 N -Wall-12F-0sw 40 X 9 332 0.065 5.7 1,877 0.9 0 287 W -Wall-12F-0sw 36 X 9 211 0.065 5.7 1,193 0.9 0 182 E -Wall-12F-0sw 36 X 9 218 0.065 5.7 1,233 0.9 0 188 W -Door-11N 3 X 7 21 0.350 30.5 639 8.4 0 176 W -Door-11N 3 X 7 21 0.350 30.5 639 8.4 0 176 S -Gls-4A-1a-o shgc-0.33 0%S 4 0.320 27.8 111 19.3 0 77 N -Gls-4A-1a-o shgc-0.33 100%S 28 0.320 27.8 780 10.4 0 292 W -Gls-4A-1a-o shgc-0.33 0%S 71 0.320 27.8 1,977 35.0 0 2,485 E -Gls-4A-1a-o shgc-0.33 0%S 106 0.320 27.8 2,951 35.0 0 3,711 Subtotals for Structure:13,413 0 7,882 Infil.: Win.: 41.0, Sum.: 21.3 1,368 2.786 3,811 0.216 412 296 People: 200 lat/per, 230 sen/per:2 400 460 Equipment:1,000 3,000 Room Totals:17,224 1,812 11,638 C:\ ...\17924 EVERSHED LAKEVILLE 11182021.rhv Thursday, November 18, 2021, 9:33 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 18 Detailed Room Loads - Room 2 - Upper Level (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:1,123.0 ft.System Number:1 Room Width:1.0 ft.Zone Number:1 Area:1,123.0 sq.ft.Supply Air:576 CFM Ceiling Height:9.0 ft.Supply Air Changes:3.4 AC/hr Volume:10,107.0 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:7 Actual Winter Vent.:54 CFM Runout Air:82 CFM Percent of Supply.:9 % Runout Duct Size:6 in.Actual Summer Vent.:30 CFM Runout Air Velocity:419 ft./min.Percent of Supply:5 % Runout Air Velocity:419 ft./min.Actual Winter Infil.:42 CFM Actual Loss:0.110 in.wg./100 ft.Actual Summer Infil.:22 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain N -Wall-12F-0sw 42 X 9 348 0.065 5.7 1,968 0.9 0 301 S -Wall-12F-0sw 42 X 9 368 0.065 5.7 2,081 0.9 0 318 E -Wall-12F-0sw 36 X 9 247 0.065 5.7 1,397 0.9 0 214 W -Wall-12F-0sw 36 X 9 252 0.065 5.7 1,425 0.9 0 218 N -Gls-4A-1a-o shgc-0.33 100%S 30 0.320 27.8 835 10.4 0 312 S -Gls-4A-1a-o shgc-0.33 0%S 10 0.320 27.8 278 19.2 0 192 E -Gls-4A-1a-o shgc-0.33 0%S 77 0.320 27.8 2,144 35.0 0 2,695 W -Gls-4A-1a-o shgc-0.33 0%S 72 0.320 27.8 2,004 35.0 0 2,520 UP-Ceil-16B-50 1123 X 1 1123 0.020 1.7 1,954 1.0 0 1,078 Subtotals for Structure:14,086 0 7,848 Infil.: Win.: 42.1, Sum.: 21.9 1,404 2.786 3,912 0.217 423 304 People: 200 lat/per, 230 sen/per:5 1,000 1,150 Equipment:1,000 3,000 Room Totals:17,998 2,423 12,302 C:\ ...\17924 EVERSHED LAKEVILLE 11182021.rhv Thursday, November 18, 2021, 9:33 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 19 Detailed Room Loads - Room 3 - Lower Level (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:1,095.0 ft.System Number:1 Room Width:1.0 ft.Zone Number:1 Area:1,095.0 sq.ft.Supply Air:205 CFM Ceiling Height:9.0 ft.Supply Air Changes:1.2 AC/hr Volume:9,855.0 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:2 Actual Winter Vent.:34 CFM Runout Air:102 CFM Percent of Supply.:17 % Runout Duct Size:6 in.Actual Summer Vent.:11 CFM Runout Air Velocity:521 ft./min.Percent of Supply:5 % Runout Air Velocity:521 ft./min.Actual Winter Infil.:10 CFM Actual Loss:0.169 in.wg./100 ft.Actual Summer Infil.:5 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain S -Wall-15B0-10sf-10 40 X 9 360 0.049 4.3 1,535 0.0 0 0 N -Wall-15B0-10sf-10 40 X 9 360 0.049 4.3 1,535 0.0 0 0 W -Wall-15B0-10sf-10 36 X 9 324 0.049 4.3 1,381 0.0 0 0 E -Wall-12F-0sw 36 X 9 249 0.065 5.7 1,408 0.9 0 215 E -Gls-4A-1a-o shgc-0.33 0%S 75 0.320 27.8 2,088 35.0 0 2,625 Floor-21A-24 1 X 1095 1095 0.025 2.2 2,382 0.0 0 0 Subtotals for Structure:10,329 0 2,840 Infil.: Win.: 9.7, Sum.: 5.1 324 2.787 903 0.216 98 70 People: 200 lat/per, 230 sen/per:2 400 460 Equipment:500 1,000 Room Totals:11,232 998 4,370 C:\ ...\17924 EVERSHED LAKEVILLE 11182021.rhv Thursday, November 18, 2021, 9:33 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 20 Room Cooling and Heating Loads Bar Graphs Cooling Heating Btuh Lower Level Upper Level Main Level 0 5,000 10,000 15,000 20,000 C:\ ...\17924 EVERSHED LAKEVILLE 11182021.rhv Thursday, November 18, 2021, 9:33 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 21 Room Cooling Loads Bar Graphs Sensible Latent Btuh Lower Level Upper Level Main Level 0 5,000 10,000 15,000 C:\ ...\17924 EVERSHED LAKEVILLE 11182021.rhv Thursday, November 18, 2021, 9:33 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 22 System 1 Room Load Summary No Room Name Area SF Htg Sens Btuh Min Htg CFM Run Duct Size Run Duct Vel Clg Sens Btuh Clg Lat Btuh Min Clg CFM Act Sys CFM ---Zone 1--- 1 Main Level 1,095 17,224 359 6-6 463 11,638 1,812 545 545 2 Upper Level 1,123 17,998 375 7-6 419 12,302 2,423 576 576 3 Lower Level 1,095 11,232 234 2-6 521 4,370 998 205 205 Ventilation 4,550 340 1,352 System 1 total 3,313 51,004 967 28,650 6,585 1,326 1,326 System 1 Main Trunk Size:24x10 in. Velocity:796 ft./min Loss per 100 ft.:0.089 in.wg Cooling System Summary Cooling Tons Sensible/Latent Split Sensible Btuh Latent Btuh Total Btuh Net Required:2.94 81% / 19%28,650 6,585 35,235 Actual:1.00 77% / 23%9,240 2,760 12,000 Equipment Data Heating System Cooling System Type:Natural Gas Furnace Standard Air Conditioner Model:QC-F38-E78-G QC-C12 Indoor Model:S12 Brand:Quikcool FE Series Quikcool AS Series Description:Hi Efficiency Furnace Standard Efficiency Air Condit Efficiency:78.3 AFUE 12.4 SEER Sound:8.1 bels Capacity:38,000 Btuh 12,000 Btuh Sensible Capacity:n/a 9,240 Btuh Latent Capacity:n/a 2,760 Btuh C:\ ...\17924 EVERSHED LAKEVILLE 11182021.rhv Thursday, November 18, 2021, 9:33 AM Builders Associaton of Minnesota version 101014 Date Certificate Posted x Passive (No Fan) Active (With fan and monometer or other system monitoring Location (or future location) of Fan: Other Please Describe Here x 10/15 x x x 20 x 20 x 21 x 49 x x x x x Not applicable, all ducts located in conditioned space x Not required per mech. code Passive Powered Interlocked with exhaust device. Describe:Input in BTUS: 70,000 Capacity in Gallons: Other, describe: AFUE or HSPF% 93% Cfm's " round duct OR " metal duct Not required per mech. code x Passive Low: Other, describe: x Low: Location of fan(s), describe: Cfm's 4" " round duct OR Flex " metal duct ML193UH070 Heating Loss Manufacturer Lennox Natural Gas Output in Tons: 3 Ton50 Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Capacity continuous ventilation rate in cfms: 200CFM Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): 28,650Residential Load Calculation SEER /EER Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Electric Make-up Air Select a Type AO Smith Domestic Water Heater MECHANICAL SYSTEMS Rating or Size Efficiency 13 Seer Building envelope air tightness: Rim Joist (1st Floor) GPVL-50 13ACXN042-230 Model Heating System Natrual Gas Lennox Fiberglass, Batts Foundation Wall R-value Average U-Factor (excludes skylights and one door) U: Duct system air tightness: Cooling SystemTotal R-Value of all Types of InsulationType: Check All That Apply Mineral Fiberboard Insulation Location Foam, Closed Cell0.22 Describe other insulated areas Fiberglass, BlownTHERMAL ENVELOPE Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM Non or Not ApplicableAttic Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area Rim Joist (2nd Floor+) 0.30 Appliances Mech Room Heat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: 51,004 Heating Gain Cooling Load Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. Place your logo here New Construction Energy Code Compliance Certificate Name of Residential Contractor Stone Cottage Construction Inc. MN License Number Lakeville17924 Evershed Way BC636874 City Mailing Address of the Dwelling or Dwelling Unit Combustion Air Select a Type Location of duct or system: 35,235 Below Entire Slab Rigid, Extruded Polystyrene Ceiling, flat NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. New residential building permits WILL NOT be issued without this completed form. Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ Primary Contact: _________________________________________________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Description of Land Disturbing Activity: _____________________________________________________ NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___ If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an erosion and sediment control plan MUST be submitted with the residential building permit application. “The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.” (NPDES Construction Stormwater Permit, MPCA) “The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA) Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name of Person: ________________________________Company: _______________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: ________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots. No land disturbing activity may begin until a residential building permit has been issued. I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 KP X12/16/21