Loading...
HomeMy WebLinkAbout16440 - 46 - 52 - 58 Jaffna Place SurveySURVEYOR'S CERTIFICATEDenotes set spikeDenotes set iron monumentDenotes found iron monumentDenotes proposed drainageDenotes top of curbDenotes existing elevationDenotes proposed elevationPHONE: 952.890.6044 www.jrhinc.com PLANNERS / ENGINEERS / SURVEYORS CERTIFICATE OF SURVEY FORDRAWN BYDATEREVISIONSTAMCAD FILEPROJECT NO.SHEET 1 OF 1Lots 43, 44, 45, and 46, Block 1, CRYSTAL PARK, Dakota County, MinnesotaI hereby certify that this survey, plan or report wasprepared by me or under my direct supervision andthat I am a duly Licensed Land Surveyor under thelaws of the State of Minnesota. That this surveydoes not purport to show all improvements,easements or encroachments, to the propertyexcept as shown thereon.Signed this 21st day of December, 2021Marcus F. Hampton, MN L.S. No. 4748112/15/2021411687-90.dwg411687-902999 WEST C.R. 42, SUITE 100, BURNSVILLE, MN 55306Lots 43, 44, 45, and 46, Block 1, CRYSTAL PARK,Dakota County, MinnesotaPROPERTY DESCRIPTION16440, 16446, 16452, and 16458 Jaffna Place,Lakeville, MinnesotaPROPERTY ADDRESS1. Bearings are based on the recorded plat.2. Building dimensions shown are for horizontaland vertical placement of structure only. Seearchitectural plans for building andfoundation dimensions.3. No specific soils investigation has beencompleted on this lot by James R. Hill, Inc. thesuitability of soils to support the specifichouse proposed is not the responsibility ofJames R. Hill, Inc. or the surveyor.4. No specific title search for existence ornon-existence of recorded or un-recordedeasements has been conducted by thesurveyor as a part of this survey. Onlyeasements per the recorded plat are shown.5. Proposed grades shown were taken from thegrading &/or development plan prepared byJames R. Hill, Inc.6. Grading plan date/revision date: 9/14/2021.7. Plan No. 2620-L, 2625-M, 2625-N, 2620-PNOTESFLOOR ELEVATIONSBENCHMARKProposedLot 43 Lots 44-45 Lot 46Garage Floor @ Front = 998.8 = 999.8 = 1000.8Garage Top of Block = 999.2 = 1000.2 = 1001.2House Top of Block = 999.2 = 1000.2 = 1001.2Lowest Floor = 999.2 = 1000.2 = 1001.2Top nut of hydrant located at Lot 15, Block 1 = 998.42A. 12/23/21: ClientB. 12/30/21: ClientC. 1/20/22: CityPlanning DepartmentApprovedDate:__________________01/19/2022kjensonThe curb box, drain tile cleanout, and catchbasin(if applicable) must be inspected andaccepted before As-Built escrow monies willbe released. All structures must be flushwith the sod. This will be scheduled with thelandscape inspection.ENGINEERING REVIEWEDDate:__________________01/26/2022corlowskyEROSION CONTROLMUST BE INSTALLEDBEFORE EXCAVATION*Maintain 6" between bottom of siding and sod.*No structures in easements.