Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LA199089 - 7404 204th St W Permit Pack
RESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: SIZING OF POTABLE WATER PIPING Total Fixture Units: 52.5 Total Length: 100 Ft Water Service Size: 1" Water Meter Size: 1" Water Heater Feed: 1" Building Supply To First Branch: 1-1/4" Softener Inlet Size: 1-1/4 " FACE APPLIED STONE VENEERSEE A3 OPT 2VERTICAL BOARD & BATTEN SIDINGFACE APPLIED STONE VENEERHORIZONTAL LAP SIDINGVINYL SIDING ON FRONT ELEVATION.VINYL SIDING ON SIDE AND REAR ELEVATIONS.HORIZONTAL LAP SIDING 7404 204th Street West Cedar Hills-2nd AdditionSecure door closed until deck isconstructed with a separate permit.Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode01/28/2022dmathews UFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. ·····················-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ). ℄412℄412412℄412℄ Sheet:1of4A complete Javelin® framing plan requires the Framer's Pocket GuideSee the Framer's Pocket Guide for Product Trademark InformaƟonLack of proper bracing during construction can result in seriousaccidents. Observe the following guidelines:WARNING NOTES:WARNINGJoists are unstable until braced laterallyBracing Includes:BlockingHangersSheathingRim BoardStrut LinesRim JoistDO NOT stack buildingmaterials on unsheathedjoists. Stack only overbeams or walls.DO NOT walk on joiststhat are lying flat.DO NOT walk on joistsuntil braced.INJURY MAY RESULT.Weyerhaeuser, Microllam, Parallam, TimberStrand, TJI, TJ, and Trus Joist are registered trademarks ofWeyerhaeuser NR. © 2014 Weyerhaeuser NR Company. All rights reserved.1. All blocking, hangers, rim boards and rim joists at the end supports of the TJI® joists must be completely installed and properly nailed.2. Laterial strength, like braced end wall or an existing deck, must be established at the ends of the bay. This can also beaccomplished by a temporary or permanent deck (sheathing) fastened to the first 4 feet of joists at the end of the bay.3. Safety bracing of 1x4 (minimum) must be nailed to a braced end wall or sheathed area (as in note 2) and to each joist.Without this bracing, buckling sideways or rollover is highly probable under light construction loads - such as a worker orone layer of unnailed sheathing.5. Ends of cantilevers require safety bracing on both the top and bottom flanges.6. The flanges must remain straight within 1/2" from true alignment.4. Sheathing must be completely attached to each TJI® joist before additional loads can be placed on the system.*Conventional construction code minimum for usewith A3 only. See the Weyerhaeuser TJI®Specifier's Guide, #TJ-4000, for A3.1-A3.3installation specifications and applications.Plate nail - 16d (0.135" x 312")at 16" on-center*Floor panel nail - 8d (0.131"x 212") at 6" on-center*Toe nail - 10d (0.131" x 3")at 6" on-center*114" TimberStrand®LSL or118" TJ® rim board.*When sheathing thickness exceeds 78",trim sheathing tongue at rim boardA3A3.2A3.1 A3.3Load bearing or braced/shear wallabove (must stack over wall below)Blocking panel: 118" TJ® Rim Board, 114"or 112" TimberStrand®LSL or TJI® joist.Web stiffeners requiredon both sides at B1Wand B2W ONLYB1WB1B2B2W116"2x4 minimumsquash blocksBlocking panels may be required with braced/shearwalls above or below — see detail B1Use 2x4 minimum squash blocks totransfer load around TJI® joistCSLoad from above2x4 minimumsquash blocks116"BlockingpanelEnd of joistsat centerlineof supportB4Load bearing or shear wallabove (must stack overwall below when present)2'TJI® JOIST2"2x6 (min.) solid sawn or 4 12" wideTimberstrand® LSL rim board, full lengthin bay and tight to each joist flange. Connectto plate with 8d (0.113" x 2 38") nails at 6"on-center.2416 span rated sheathing (716" Min.).Attach with 8d (0.113" x 2 38") nails at6" on-center along panel edges and infield. Use pressure treated plywoodfor ground level cantilevers.E1 ALTTimberstrand ® LSL rim boardto match TJI® depthWARNINGJoists are unstable until braced laterally,Safety bracing required during installation.Lateral load transfer for this detail is180 PLF (pounds per lineal foot).Additional connections may be requiredto transfer lateral loads from wall above.8" diameter maximum hole for 1178" -16" deep blocking panels; 6" diametermaximum for blocking panels 912"deep or shorter than 12" long.Do not cut flanges.E1E1WWeb stiffenersrequired on bothsides at E1W ONLY118" TJ® Rim Board or114" or 112" TimberStrand® LSL.Nail with 10d (0.131" x 3")nails, one each at top andbottom flange.Variable slope joisthanger. Beveled webstiffener required eachside.LSTA24 (Simpson Strong-Tie or USP StructuralConnectors) strap with twelve 10d (0.148 x 112")nails required at H5S with slopes greater than 3:12H5H5SStrap nails:Leave 238" minimumend distanceAdditional blockingmay be requiredfor shear transfer.H5S is allowed only with joist depths < 16''_LOLDouble joistmay be requiredwhen L exceedsjoist spacing2x_ overhang. Notcharound TJI® joist topflange.Blockingas requiredEnd wallR5Beveled web stiffeners required onboth sides. Cut to match roof slope.2x4 block for soffit supportBIRDSMOUTH CUT allowed at low end of joist only 2'-0"maximumTJI® joist flangemust bear fully onplate.Birdsmouth cutmust notoverhang insideface of plate.R92x4 one side. Use 2x6 ifjoist spacing is greater than24" on-center.10d (0.128" x 3")nails at 8"on-centerBeveled 2x4 blockBeveled web stiffenerson both sidesBIRDSMOUTH CUT allowed at low end of joist only4'-0"minimum2'-0"maximumR14Strap nails:Leave 238" minimumend distanceDouble beveled bearing platewhen slope exceeds 14:12LSTA18 (Simpson Strong-Tie® or USPStructural Connectors®) strap withtwelve 10d (0.148" x 112") nailsAdditional blockingmay be required forshear transferWeb Stiffener required onboth sides at R14W ONLYWR7R7Web stiffenersrequired on bothsides at R7W ONLYBeveled bearingplate required whenslope exceeds 14:12INTERMEDIATE BEARINGBlocking panels or shear blocking may bespecified for joist stability at intermediate supportsR7STwist strap and backer block required atR7S with slopes greater than 3:12. SeeNailing Requirements at Bearing inWeyerhaeuser Installation Guide for Floorand Roof Framing, TJ-9001.R7S is allowed only with joist depths < 16''_NAILING FOR TOP & BOTTOM PLATE TO SHEATHING & CEILING/ROOF MEMBERSSHEATHING NAILING(16d PNUEMATIC NAILS)NAILS/FT16" o.c.24" o.c.NON-HURRICANE PRONE REGIONS 3 4 6HURRICANE PRONE REGIONS 4 6 8120 MPH WIND AREA 5 7 10CEILING/ROOF MEMBER SPACINGP5L13 P6Header to columnHeaderColumnColumn to Top PlateFraminganglesas requiredTrimmerStud (s)Plate widthmust equal wallthickness toprovide lateralbracing. (Platenot required ifheader widthequals the wallthickness.)Trimmerstud (s)Doubletop plateFraminganglesas requiredSolid blocking isrequired if columnand trimmer studsdo not extend tosill plateBlockingpanel asrequiredTrimmerstud (s)Framinganglesas requiredRimboardSill PlateSoleplateColumnColumn to Bottom PlateA notch and hole shall not occurin the same cross sectionMaximum diameter:*138" for 312" thick walls*2316" for 512"-1114" thick wallsMaximum notch:One hole may be cut anywwhere along the length ofthe stud or column but must be at least 58" from the edge.One notch may be cut anywhere except themiddle 13 of the length of the stud or column.*78" for 312" thick walls*138" for 512"-1114" thick walls58" Minimumedge distanceL/3L/3L/3Allowable Holes and Notches*Note: Field skewableframing angles requiredfor sloped top plateconnectionsWB2Connection of double top plate to outlooker must bedesigned to tranfer lateral load to roof.Connect outlooker to double topplate with angle clip (565 lbs min.for Load 1) at 24" o.c.2x_ outlookerContinuous tall-wall framing(from sill plate to top plate)4" o/c nailingrequired fromsheathingto outlookerBlocking betweenoutlookers asrequiredConnect outlooker to trusswith (2) 16d nails for 2x4,(3) 16d nails for 2x6 or 2x82' maxWB3Loads must be trackedto foundation by designerof recordTrusses by othersat 24" on centerConnect truss todouble top platewith one angleclip (545 lbs min.for Load 2) at24" o.c.Gable end wall2x_ solid sawn angle braces toconnect double top plate to roof @ 2'-0"o.c. along length of wall fit snug betweenthe two bays. Connect with (3) 16d nails.2x_ solid sawn connected to topof bottom chord with (3) 16d nails at2'-0" o.c. along length of wall, back 8'-0"Wall bracing is necessary if double top plate is not attacheddirectly to the roof/floor diaphragm.25° to45°Member OrientationPlate width must equal wall thicknessto provide lateral bracing (plate notrequired if header equals wall thickness)MULTIPLE MEMBER CONNECTIONS FOR POINTLOADED COLUMNS2 PLY 3 PLY 4 PLYUSE 16d (0.131" x 314") PNEUMATIC NAILS4 PLY ALTERNATE: 2 ROWS, 12" DIAMETER BOLTS AT 8" ON-CENTERMULTIPLE MEMBER CONNECTION FOR NON POINT LOADEDCOLUMNS2 PLY, USE (2) ROWS 16d PNEUMATIC NAILS AT10" O.C.3 PLY'S AND GREATER, USE (2) ROWS 16d PNEUMATIC NAILS (EACH PLY) AT 8" O.C.- STAGGER 2" PER PLYDO NOT cut, notch or drillholes in headers or beamsexcept as indicated inillustrations and tables.DO NOTcut or notch flange.DO NOTcut holes in cantileverreinforcement.112" hole may be cutanywhere in web out-side of hatched zoneMin. distance from Table ANo field cutholes inhatchedzonesMinimum distance from edge of hole to inside face of nearest end supportminimum(applies to all holesexcept knockouts)Table A - End Support6"6"1L12 x D1DDL2 x Lminimum226"6"2ALLOWABLE HOLES - TJI® Joists1.3E TimberStrand®LSL allowed hole zoneddMicrollam®LVL andParallam® PSLallowed hole zonemiddle 13 span1.3E TimberStrand®LSL hole zoneMicrollam®LVLand Parallam® PSLhole zone2 x diameter of thelargest hole (minimum)d13 depth1"2"134"Maximum RoundHole SizeHeader or Beam Depth438"714"- 20"512"See illustration for Allowed Hole ZoneOther Trus Joist® Headers and Beams1.55E TimberStrand®LSL Headers and BeamsALLOWABLE HOLES - Headers and Beams13 depth2 x diameter of thelargest hole (minimum)8"See illustration for allowed hole zone1114"-11 78"14"-16"914"-912"358"458"3"No holes in headers or beams in plank orientation.Round holes onlyGeneral NotesGeneral NotesNo holes in headers or beams in plank orientation.Allowed hole zone suitable for headers and beams with uniform loads only.Round holes onlyNo holes in cantilevers.Allowed hole zone suitable for headers and beams withuniform and/or concentrated loads.Maximum RoundHole SizeHeader or Beam Depth8"Allowed hole zoneMin. distance from Table BDo not cut holes largerthan 112" in cantilever6"Closely grouped roundholes are permitted ifthe group perimetermeets requirements forround or square holes.10'-0" 11'-6"3'-0"1'-0"1'-0" 1'-6" 9'-0"9'-0"6'-6"4'-6"1'-0" 1'-0"1'-0"3601'-0"12'-0"17"13"15'-6"15'-6"SQUARE OR RECTANGULAR HOLE SIZEMinimum distance from edge of hole to inside face of nearest intermediate or cantilever support16'-6"16'-0"21'-0"20'-6"18'-0"17"17'-0"For simple span (5' minimum), uniformly loaded joists used in residential applications, one maximum size round hole may be locatedat the center of the joist span provided that no other holes occur in the joist.Distances are based on the maximum uniform loads from current Trus Joist specifier's guides. For other load conditions or holeconfigurations use Forte® software or contact your Weyerhaeuser representative.15"8"10"6"4" 12"17"15"12"10"8"6"4"16'-0"15'-6"Holes may be located vertically anywhere within the web. Leave 18" of web (minimum) at top and bottom of hole.Knockouts are located in web at approximately 12" on-center; they do not affect hole placement.1'-0"1'-0"1'-0"1'-0"Rectangular holes based on measurement of longest side.18"20"1'-0"5605603603601'-0"1'-0"1'-0"1'-0" 1'-6"1'-0"2'-0"3'-0"3'-0"6'-0"6'-0"12'-0"5'-6"16'-6"11'-0"15'-0"10'-0"6'-0"9'-0"6'-0"3'-0"1'-6"4'-0"1'-0"1'-0"1'-0"1'-0"16'-6"18'-0"16'-6"14'-0"8'-6"7'-0"9'-0"11'-6" 16'-6"12'-6"14'-6"19'-6"17'-6'19'-0"20'-0"19'-6"10'-0"17"11'-0"13"10'-6"ROUND HOLE SIZETable B - Intermediate or Cantilever Support11'-0"10'-0"15'-0"13'-6"4'-0" 8'-6"2'-6"2303'-0"1'-0"1'-0"1'-0"1'-0"3'-0"3'-0"1'-0"1'-0"4'-0"1'-0"2'-0"1'-0"1'-0"1'-0"1'-0"1'-0"16"14"2305603601'-0"1'-0"1'-0"2305602103601'-0"1'-0"1'-0"1'-0"1178"1'-0"2303601102105602'-0"1'-0"1'-6"3602101103'-0"1'-0"1'-0"9'-6"5'-6"1'-0" 2'-6"1'-0"1'-0"1'-0"1'-6"2'-6"3'-0"1'-0"1'-0"1'-6"2'-0"1'-0"5'-6"5'-6"3'-6"11'-0"10'-0"4'-0"7'-0"6'-6"6'-6"10'-6"13'-6"12'-6"6'-0"9'-6"3'-6"8'-6"6'-0"2'-6" 5'-0"4'-0"1'-0"4'-6"7'-0"2'-0"8'-0"5'-6"2'-0"1'-6"4'-6"4'-0"9'-0"10'-0"11'-0"4'-6"12'-0"8'-6"9'-0"8'-6"6"3"1'-0"1'-0"1'-0"1'-0"1'-0"2'-6"2'-6"912"TJI®2101102"2'-0"2'-0"18"20"1'-0"3605605603601'-0"1'-0"1'-0"5601'-0"4"4"3'-6"3'-6"612"8'-0"7'-6"878"11"1'-0" 2'-0"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"8"10"1'-0"10'-0"5'-0"11'-0"5'-0"1'-0"2'-0"7'-0"7'-0"5'-0"12"7'-6"15"7'-6"3'-6"2'-0" 4'-6"4'-6"2'-0"1'-6"3'-6"2'-6"1'-0"1'-0"1'-0"3'-0"1'-0"1'-0"2'-0"4'-6"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"2'-0"1'-0"3'-0"3'-0"1'-0"1'-0"13'-0"6'-0"2'-0" 10'-0"10'-6"13'-6"12'-0"11'-0"14'-6"13'-0"1'-0"3'-6"2'-0"5'-0"9'-0"7'-6"1'-0"5'-0"4'-0"2'-6" 6'-6"4'-6"10'-0"9'-0"13'-6"16'-0"14'-6"13'-6"12'-6"15'-0"14'-0"10'-0"12'-0"11'-0"10'-6"10'-0"8'-6"3'-6"5'-0"1'-0"6'-0"9'-6"5'-0"10'-6"5'-6"3'-0"2'-6"8'-0"8'-0"7'-0"12'-0"9'-0"9'-6"2'-0"6"1'-6"1'-0"1'-0"3"1'-0"3'-0"2'-6"2'-0"1'-6"2"1'-0"1'-0"1'-0"1'-0"1'-0"4"4'-0"3'-6"4"612"7'-6"6'-6"11"878"10'-0"12'-0"11'-6"11'-0"10'-0"5'-0"6'-6"4'-0"2'-6"11'-0"9'-6"8'-0"3'-0"8"4'-6"10"13'-6"14'-6"14'-6"14'-0"12'-6'11'-0"15"12"13"11'-0"11'-0"SQUARE OR RECTANGULAR HOLE SIZE13"6'-0"7'-0"ROUND HOLE SIZE1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"1'-6"2'-0"2'-0"1'-6"1'-6"1'-0"1'-6"1'-0"2'-0"2'-6"1'-6"56016"14"1'-0"3602102305601'-0"1'-0"1'-0"2102301101'-0"1'-0"1'-0"1178"912"1102303602101'-0"1'-0"1'-6"1'-0"1102303602101'-0"1'-6"1'-6"1'-0"8'-0"3'-0" 4'-0"1'-6"1'-0"1'-0"2'-0"1'-0"1'-0"1'-0"1'-0"1'-0" 1'-0"1'-6"8'-0"5'-6"2'-6"3'-0"6'-6"3'-6"4'-0"9'-0"3'-6"4'-0"3'-0"6'-0"7'-0"5'-6"1'-6"2'-0"3'-0"2'-0"2'-0"3'-6"2'-6"2'-0"2'-0"2'-6"3'-0"2'-6"4'-0"3'-6"3'-0"3'-0"5'-6"6'-6"7'-0"6'-0"3"JOISTDEPTHTJI®2" 4" 878"11"1'-6"2'-0"1'-6"2'-6"2'-0"2'-0"3'-6"2'-6"1'-0"1'-6"1'-0"1'-0"1'-6"1'-0"1'-0"3'-0"2'-6"1'-0"1'-0"1'-0"1'-6"1'-0"1'-0"1'-0"1'-0"1'-0"1'-6"1'-0"1'-0"1'-0"1'-6"1'-0"5'-6"4'-6" 8'-0"4'-0"2'-6"1'-0"1'-0"4'-0"2'-0"2'-0"5'-0"2'-0"1'-6"2'-0"3'-0"2'-6"2'-0"9'-6"8'-0"9'-0"8'-0"10'-0"7'-0"6'-6"9'-0"9'-0"8'-6"8'-0"7'-0"6'-0"6'-6"2'-0"3'-6"2'-6"2'-6"2'-6"4'-6"3'-6"3'-0"3'-6"3'-0"2'-6"2'-6" 3'-6"5'-0"4'-6"4'-0"7'-6"7'-0"6'-6"6'-0"3"2" 4" 11"878"612"5'-6"5'-0"5'-6"6'-0"3'-0"3'-0"4'-6"2'-6"2'-0"2'-6"1'-6"4'-6"1'-0"1'-6"3'-6"5'-6"2'-6"2'-6"612"4'-6"5'-0"5'-0"5'-6"5'-0"5'-6"6'-6"4'-6"3'-6"4'-0"4'-0"7'-0"3'-6"3'-0"6'-0"7'-0"6'-6"5'-0"3'-6"3'-6"5'-0"3'-0"2'-6"2'-6"2'-0"5'-0"1'-6"1'-6"4'-0"6'-0"3'-0"2'-6"5'-6"5'-6"6'-6"5'-0"4'-0"4'-6"5'-0"7'-6"4'-0"3'-6"6'-6"7'-6"7'-0"5'-6"5"5"7"7"1'-6"2'-6"3'-0"5"4'-6"5'-0"2'-6"3'-0"6'-6"5'-6"1'-0"5'-6"3'-6"3'-6"3'-6"1'-0"2'-0"1'-0"1'-0"1'-0"1'-0"5'-6"7"4'-6"3'-0"2'-0"3'-6"4'-0"4'-0"1'-0"6'-6"6'-0"5'-6"7'-6"2'-6"8'-6"5'-0"7"5"5'-6"6'-6"3'-6"2'-6"5'-6"4'-0"4'-0"1'-6"7'-0"5'-6"5'-0"7'-0"2'-6"8'-0"7'-6"4'-6"4'-0"6'-6"8'-0"11'-0"6'-0"9'-6"9'-0"10'-0"11'-0"5'-6"7'-6"8'-6"10'-0"6'-0"7'-0"7'-0"5"1'-0"1'-0"1'-0"1'-0"7"1'-0"1'-0"1'-0"1'-0"5" 7"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"3'-0"4'-0"5"1'-0"1'-0"1'-0"1'-0"1'-6"1'-0"1'-0"1'-0"7" 5"1'-0"1'-0"3'-6"1'-6" 6'-6"4'-0"6'-0"8'-6"7"JOISTDEPTHEXTERIOR DECK ATTACHMENTStructural exterior sheathingSee fastenertable below. Maintain2" distance (minimum) fromedge of ledger to fastener.LAFlashingTreated 2x_ledger118" TJ® Rim Boardor 114" or 112"TimberStrand®LSL.(1) Corrosion-resistant fasteners required for wet-service applications.(2) Allowable load determined in accordance with ASTM D7672.(3) 118" TJ® Rim Board is allowed with joist depths < 16" only.(4) Maximum 12" shimmed air space.Fastener Allowable Load (lbs/bolt)48012" lag bolt118" TJ® Rim BoardRim Board Material1 14" TimberStrand® LSL1 12" TimberStrand® LSL61067569512" Through bolt72572512" Through boltwith Air Space615(2)(3)(4)_Load bearing wall above(must stack over wall below)Web stiffeners required onboth sides at B5W ONLYB5B5WPer IRC R502.7,blocking required ateach intermediatesupport in seismicdesign categoriesD0, D1, and D2.Blocking panels may be required with shearwalls above or below — see detail B1TJI® 560 floor joistTop ViewNAILING AT BEARING (FLOOR)134" minimum end bearingsingle-family applicationsTJI® Joist to Bearing Plate118" TJ® Rim Board,114" or 1 12" TimberStrand® LSL. or TJI® 110 rim joist:One 10d (0.131" x 3") nail intoeach flangeTJI® 210, 230, and 360 rim joist:One 16d (0.135" x 312") nail intoeach flange.With depths > 16", use TJI® 360 rim joist.Shear transfer: Connections equivalentto floor panel nailing scheduleTJI® 560 rim joist: Toenail with 10d (0.128" x 3")nails, one each side ofTJI® joist flangeRim to TJI® JoistSquash Blocks to TJI® Joist(Load bearing wall above)One 10d (0.128" x 3")nail into each flange118" TJ® Rim Board or114" or 1 12" TimberStrand® LSL.Also see detail B2Locate rim board joint between joists.134" minimum bearingOne 8d (0.113" x 212")nail each side. Drivenails at an angle atleast 112" from end.312" minimumintermediate bearing514" may be requiredfor maximumcapacityThese placement plans have been developed for the specificaƟon of productsbased on project informaƟon provided. This service is solely intended forproduct applicaƟon assurance; and, is not intended to circumvent the need fora design professional as determined by the building code. The designer ofrecord and/or builder/framer is responsible to assure these drawings arecompaƟble with the overall project.CANTILEVERS/TRUSSESDesign assumes all trusses at floor canƟlevers are connectedto the wall and NOT to the Trus Joist rimboard. If trusses needto connect to the Trus Joist rimboard, contact Weyerhaeuserfor a connecƟon detail prior to installaƟon.JOIST & BEAM HANGER FACE NAILING REQUIREMENTS* FOR3 & 4 PLY SUPPORTING MEMBERSFor IUS or THF Hangers - Use 10D (0.148") x 3" nails.For MIU, HU, HHUS, HGUS or HD, THD, THDH Hangers - Use16d (0.162") x 3 1/2" nails.*For hangers that have joist fasteners/connecƟons, fill allholes with the manufacturer's recommended fasteners. Start Framing Here.Framing Connector SummaryPlotID Qty Manuf Product Backer Blks Web StiffH3 21 Simpson LUS210 No NoProductsPlotID Length Product Plies Net QtyFBk1 54' 4 5/16" 11 7/8" TJI 210 joist 1 1TS2 34' 0" 1 1/2" x 11 7/8" 1.5E TimberStrand LSL 1 6TS4 26' 0" 1 1/2" x 11 7/8" 1.5E TimberStrand LSL 1 9TS5 18' 0" 1 1/2" x 11 7/8" 1.5E TimberStrand LSL 1 16TS7-2 17' 0" 1 1/2" x 11 7/8" 1.5E TimberStrand LSL 2 2TS8 12' 0" 1 1/2" x 11 7/8" 1.5E TimberStrand LSL 1 4TS11 8' 0" 1 1/2" x 11 7/8" 1.5E TimberStrand LSL 1 4TS12 7' 0" 1 1/2" x 11 7/8" 1.5E TimberStrand LSL 1 1TS13 4' 0" 1 1/2" x 11 7/8" 1.5E TimberStrand LSL 1 1TS14-2 11' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2TS15-2 5' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2STCa1 16' 0" 1 1/8" x 11 7/8" TJ Rim Board 1 11AccessoriesPlotID Length Product Plies Net Qty23/32"x48"x96" Weyerhaeuser Edge Gold Panel (0/24) T&G SF 1 45Additional TimberStrand for Ledger @ FULL Basment-1PlotID Length Product Plies Net Qty- 50' 0" 1 1/2" x 11 7/8" 1.5E TimberStrand LSL 1 1A3A3A3A3A3B1CSCSCSB1TS14-2TS15-2TS5TS12TS11STCa1STCa1STCa1STCa1STCa1STCa1STCa1STCa1STCa1STCa1TS7-2FBk1FBk1FBk1FBk1FBk13"3"3"1' 7 3/16"1' 4"FBk1FBk1FBk1FBk1FBk1FBk1FBk1FBk1FBk1FBk1TS51' 7 3/16"1' 8 7/8"1' 5 7/16"9 7/16"1' 3 9/16"1' 7 3/16"1' 6 7/16"TS13TS5H3H3H3FBk1BBO3TS819.2" O.C.TS519.2" O.C.TS519.2" O.C.TS419.2" O.C.TS419.2" O.C.TS1119.2" O.C.TS219.2" O.C.TS219.2" O.C.H3H3H3H31' 0 7/8"1' 0 3/16"1' 5 7/16"An additional 8 PSF DL has been added to account for tileload in the mud room and bathroom on this floorAn additional 40 PSF DL has been added to accountfor stone fireplace load.An additional 20 PSF DL has been added to account forload from kitchen island counter tops.Please refer to the TCNA Handbook for Ceramic TileInstallation and the American National StandardsInstitute's A108/A118/A136.1-1999 for information oninstalling ceramic tile on 19.2" and 24" o.c. joist systems.See website http:/www.tileusa.com/.Blocking per site requirement.Refer to Hanson's detail 2/S2SEE DETAIL FOR DECK LEDGER ATTACHMENT@ FULL FOUNDATION WITH 2 INCH FOAM.Offset bearing wall above (Typ.)Optional Stone Fireplace - ADDPlotID Length Product Plies Net QtyTS6-2 18' 0" 1 1/2" x 11 7/8" 1.5E TimberStrand LSL 2 2TS12 7' 0" 1 1/2" x 11 7/8" 1.5E TimberStrand LSL 1 1Optional Stone Fireplacel - REMOVEPlotID Length Product Plies Net QtyTS12 7' 0" 1 1/2" x 11 7/8" 1.5E TimberStrand LSL 1 1Optional Guest Suite - ADDPlotID Length Product Plies Net QtyTS5 18' 0" 1 1/2" x 11 7/8" 1.5E TimberStrand LSL 1 1TS10 9' 0" 1 1/2" x 11 7/8" 1.5E TimberStrand LSL 1 1TS11 8' 0" 1 1/2" x 11 7/8" 1.5E TimberStrand LSL 1 1Optional Guest Suite - REMOVEPlotID Length Product Plies Net QtyTS4 26' 0" 1 1/2" x 11 7/8" 1.5E TimberStrand LSL 1 1A3B1A3CSTS15-2TS12STCa1TS6-2TS10FBk1FBk1FBk1FBk1FBk1TS13H3H3H3TS519.2" O.C.TS419.2" O.C.TS1119.2" O.C.H3H31' 5 7/16"9 7/16"1' 3 9/16"11 15/16"1' 6 1/8"STONE FIREPLACE OPTIONGUEST SUITE OPTIONOptional Morning Room - REMOVEPlotID Length Product Plies Net QtyTS2 34' 0" 1 1/2" x 11 7/8" 1.5E TimberStrand LSL 1 3TS5 18' 0" 1 1/2" x 11 7/8" 1.5E TimberStrand LSL 1 5Optional Morning Room - ADDPlotID Length Product Plies Net QtyFBk1 15' 2 5/8" 11 7/8" TJI 210 joist 1 1TS1 44' 0" 1 1/2" x 11 7/8" 1.5E TimberStrand LSL 1 3TS3 28' 0" 1 1/2" x 11 7/8" 1.5E TimberStrand LSL 1 5TS9 11' 0" 1 1/2" x 11 7/8" 1.5E TimberStrand LSL 1 2STCa1 16' 0" 1 1/8" x 11 7/8" TJ Rim Board 1 2B1A3A3CSCSTS3STCa1STCa1BBO1STCa1STCa1TS9FBk1TS9FBk11' 7 3/16"1' 7 3/16"FBk1 FBk1FBk1 FBk1TS319.2" O.C.TS119.2" O.C.MORNING ROOM OPTIONSheet:2OF4A complete Javelin® framing plan requires the Framer's Pocket GuideSee the Framer's Pocket Guide for Product Trademark InformationWEEKES FOREST PRODUCTS, INC. * 2600 COMO AVENUE651-644-9807 * ST. PAUL, MN 55108LIVE LOAD:TOTAL LOAD:40DEFLECTION:L/480 LIVEL/240 TOTALDRAWN BY:JLT52WIND/EXP.:N/ADATE:03.08.21Lack of proper bracing during construction can result in seriousaccidents. Observe the following guidelines:WARNING NOTES:WARNINGJoists are unstable until braced laterallyBracing Includes:BlockingHangersSheathingRim BoardStrut LinesRim JoistDO NOT stack buildingmaterials on unsheathedjoists. Stack only overbeams or walls.DO NOT walk on joiststhat are lying flat.DO NOT walk on joistsuntil braced.INJURY MAY RESULT.Weyerhaeuser, Microllam, Parallam, TimberStrand, TJI, TJ, and Trus Joist are registered trademarks ofWeyerhaeuser NR. © 2014 Weyerhaeuser NR Company. All rights reserved.1. All blocking, hangers, rim boards and rim joists at the end supports of the TJI® joists must be completely installed and properly nailed.2. Laterial strength, like braced end wall or an existing deck, must be established at the ends of the bay. This can also beaccomplished by a temporary or permanent deck (sheathing) fastened to the first 4 feet of joists at the end of the bay.3. Safety bracing of 1x4 (minimum) must be nailed to a braced end wall or sheathed area (as in note 2) and to each joist.Without this bracing, buckling sideways or rollover is highly probable under light construction loads - such as a worker orone layer of unnailed sheathing.5. Ends of cantilevers require safety bracing on both the top and bottom flanges.6. The flanges must remain straight within 1/2" from true alignment.4. Sheathing must be completely attached to each TJI® joist before additional loads can be placed on the system.User Defined Point LoadUser Defined Line LoadUser Defined Area LoadBeam By OthersPost By OthersConstruction Detail Callout(See Framer's Pocket Guide)Excessive Point Load(WARNING: Member design did notinclude this load. Special considerationis required by the designer of record.)Required Bearing Length(Only placed at insufficient bearinglocations.)BBOPBOPL: 12KSymbol LegendLayout Start LocationSCALE: 1/4" = 1'-0"Only header openings and roof loads which affectWeyerhaeuser product sizes have been denoted on this layout.In addiƟon to any 'CS' detail callouts shown, solid blockingand/or squash blocks are required to provide verƟcal loadtransfer from all concentrated load locaƟons to foundaƟonbelow. See Pocket Framer's Guide for appropriate detail(s).Joists may be shiŌed up to 3" if floor panel edgeis supported and span raƟng is not exceeded.DO NOT CUT FLANGES.This layout is intended for the use of Trus Joist® engineeredwood products only. The subsƟtuƟon of other engineeredwood products with this layout isNOT PERMITTED. PleaseidenƟfy the TJI®, TimberStrand® LSL, Microllam® LVL, andParallam® PSL stamps on the product to ensure that thislayout is valid for the products actually installed.INSTALL (4) 2X6 SQUASH BLOCKS UNDERALL POINT LOADS AT FRONT OF HOUSE.FOR POINT LOADS OVER 10,000#CONTACT LENNAR FOR DETAILSBlocking at Kitchen Island LEVEL NOTESCurrent Date:3/8/2021File Name:MCKINLEY.jvlLevel Name:2nd FloorBuilding Code - Design Methodology:IBC 2012Members with Design Overridden:TJ-Pro Rating (Weighted Average):44Minimum Level TJ - Pro Rating & Joist:TJ-Pro rating = 34, joist = F20'(i5704)Maximum Level TJ - Pro Rating & Joist:TJ-Pro rating = 71, joist = F9'(i5868)FLOORFloor Container:FC2, FC8Use/Occupancy:ResidentialLivingAreasFloor Area Loading is:40.0 lb/ft² Live Load & 10.0 lb/ft² Dead LoadOperator Added Additional LoadsMaximum Allowed Deflection:L/480 Live Load & L/240 Total LoadTJ-Pro Rating Information:Weighted Average:FC2: 44; FC8: 44Directly Applied Ceiling:Gypsum 1/2"Decking Attachment:Glue and NailDecking Material:23/32"x48"x96" Weyerhaeuser Edge Gold Panel (0/24) T&G SFPerpendicular Partition:NoStrapping at max 8' o.c.:NoneBlocking at max 8' o.c.:NoPoured Flooring:NoFraming Connector SummaryPlotID Qty Manuf Product Backer Blks Web StiffH1 14 Simpson IUS2.06/11.88 No NoProductsPlotID Length Product Plies Net QtyF26' 26' 0" 11 7/8" TJI 210 joist 1 5F20' 20' 0" 11 7/8" TJI 210 joist 1 3F18' 18' 0" 11 7/8" TJI 210 joist 1 12F16' 16' 0" 11 7/8" TJI 210 joist 1 1F14' 14' 0" 11 7/8" TJI 210 joist 1 6FBk1 13' 0 5/8" 11 7/8" TJI 210 joist 1 1F12' 12' 0" 11 7/8" TJI 210 joist 1 5F9' 9' 0" 11 7/8" TJI 210 joist 1 1F7' 7' 0" 11 7/8" TJI 210 joist 1 7R21' 21' 0" 11 7/8" TJI 360 joist 1 7R20' 20' 0" 11 7/8" TJI 360 joist 1 4R18' 18' 0" 11 7/8" TJI 360 joist 1 1RBk1 7' 3 11/16" 11 7/8" TJI 360 joist 1 1M2-2 14' 0" 1 3/4" x 11 7/8" 2.0E Microllam LVL 2 2TS1-2 20' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2STCa1 16' 0" 1 1/8" x 11 7/8" TJ Rim Board 1 11Wall FramingPlotID Length Product Plies Net QtyTSHd1-2 10' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2AccessoriesPlotID Length Product Plies Net Qty9 1/8" 3/4" x 2 5/16" Web Stiffeners 1 1423/32"x48"x96" Weyerhaeuser Edge Gold Panel (0/24) T&G SF 1 46 Start Framing Here.E1A3A3A3A3A3B1CSB4CSCSB1B4BBOHd2-2M2-2TS1-2TSHd1-2F16'F9'STCa1STCa1STCa1STCa1STCa1STCa1STCa1STCa1STCa1BBOBk1R18'FBk1R21'FBk1FBk11' 7 3/16"1' 8 9/16"1' 3 5/16"1' 9 15/16"1' 2 1/8"1' 7 3/16"1' 7 5/16"1' 11 5/8"1' 2 3/4"BBOHd1-21' 2 3/8"1' 0 5/16"1' 7 3/16"1' 3 3/8"RBk1R21'F14'19.2" O.C.F18'19.2" O.C.F12'19.2" O.C.F26'19.2" O.C.F7'19.2" O.C.R20'19.2" O.C.R21'19.2" O.C.R21'19.2" O.C.F20'19.2" O.C.H1H11' 4 1/16"1' 6 5/16"9 1/16"An additional 8 PSF DL has been added to account for tileload in the bathrooms on this floor.An additional 25 PSF LL has been added to accountfor optional garden tub.There are different joist series of the same depth specifiedon this floor system. Verify when ordering or installing TJI®joist that the proper joists are used in the appropriateareas.Please refer to the TCNA Handbook for Ceramic TileInstallation and the American National StandardsInstitute's A108/A118/A136.1-1999 for information oninstalling ceramic tile on 19.2" and 24" o.c. joist systems.See website http:/www.tileusa.com/.NO CHANGES FOR BATHOPTIONS.Plant Ledge to be supported byRoof Trusses. Lennar to verify.ALT360 Series210 SeriesJoists by SeriesOptional Morning Room - ADDPlotID Qty Manuf Product Backer Blks Web StiffH1 6 Simpson IUS2.06/11.88 No NoH3 3 Simpson IUS2.37/11.88 No NoOptional Morning Room - ADDPlotID Length Product Plies Net QtyM1-3 17' 0" 1 3/4" x 18" 2.0E Microllam LVL 3 3Optional Morning Room - REMOVEPlotID Length Product Plies Net QtySTCa1 16' 0" 1 1/8" x 11 7/8" TJ Rim Board 1 1 Start Framing Here.STCa1M1-31' 8 5/8"1' 5 3/4"1' 7 3/16"R20'H1H319' 1 3/8"Top of Beam Flush to Top ofFloor System.MORNING ROOM OPTIONOptional Guest Suite - ADDPlotID Qty Manuf Product Backer Blks Web StiffH2 7 Simpson IUS2.06/9.5 No YesH3 1 Simpson IUS2.37/11.88 No NoOptional Guest Suite - ADDPlotID Length Product Plies Net QtyTS2-2 6' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2B1A3A3CSCSB1B4BBOHd3-2F9'STCa1TCa1R18'FBk1FBk1TS2-2RBk1H3F7'19.2" O.C.R20'19.2" O.C.F20'19.2" O.C.H2H2GUEST SUITE OPTIONSheet:3OF4A complete Javelin® framing plan requires the Framer's Pocket GuideSee the Framer's Pocket Guide for Product Trademark InformationWEEKES FOREST PRODUCTS, INC. * 2600 COMO AVENUE651-644-9807 * ST. PAUL, MN 55108LIVE LOAD:TOTAL LOAD:40DEFLECTION:L/480 LIVEL/240 TOTALDRAWN BY:JLT52WIND/EXP.:N/ADATE:03.08.21Lack of proper bracing during construction can result in seriousaccidents. Observe the following guidelines:WARNING NOTES:WARNINGJoists are unstable until braced laterallyBracing Includes:BlockingHangersSheathingRim BoardStrut LinesRim JoistDO NOT stack buildingmaterials on unsheathedjoists. Stack only overbeams or walls.DO NOT walk on joiststhat are lying flat.DO NOT walk on joistsuntil braced.INJURY MAY RESULT.Weyerhaeuser, Microllam, Parallam, TimberStrand, TJI, TJ, and Trus Joist are registered trademarks ofWeyerhaeuser NR. © 2014 Weyerhaeuser NR Company. All rights reserved.1. All blocking, hangers, rim boards and rim joists at the end supports of the TJI® joists must be completely installed and properly nailed.2. Laterial strength, like braced end wall or an existing deck, must be established at the ends of the bay. This can also beaccomplished by a temporary or permanent deck (sheathing) fastened to the first 4 feet of joists at the end of the bay.3. Safety bracing of 1x4 (minimum) must be nailed to a braced end wall or sheathed area (as in note 2) and to each joist.Without this bracing, buckling sideways or rollover is highly probable under light construction loads - such as a worker orone layer of unnailed sheathing.5. Ends of cantilevers require safety bracing on both the top and bottom flanges.6. The flanges must remain straight within 1/2" from true alignment.4. Sheathing must be completely attached to each TJI® joist before additional loads can be placed on the system.User Defined Point LoadUser Defined Line LoadUser Defined Area LoadBeam By OthersPost By OthersConstruction Detail Callout(See Framer's Pocket Guide)Excessive Point Load(WARNING: Member design did notinclude this load. Special considerationis required by the designer of record.)Required Bearing Length(Only placed at insufficient bearinglocations.)BBOPBOPL: 12KSymbol LegendLayout Start LocationSCALE: 1/4" = 1'-0"Only header openings and roof loads which affect Weyerhaeuserproduct sizes have been denoted on this layout. In addiƟon to any 'CS'detail callouts shown, solid blocking and/or squash blocks are requiredto provide verƟcal load transfer from all concentrated load locaƟons tofoundaƟon below. See Pocket Framer's Guide for appropriate detail(s).Joists may be shiŌed up to 3" if floor panel edgeis supported and span raƟng is not exceeded.DO NOT CUT FLANGES.This layout is intended for the use of Trus Joist® engineered woodproducts only. The subsƟtuƟon of other engineered wood products withthis layout isNOT PERMITTED. Please idenƟfy the TJI®, TimberStrand®LSL, Microllam® LVL, and Parallam® PSL stamps on the product to ensurethat this layout is valid for the products actually installed. Wall FramingPlotID Length Product Plies Net QtyTSHd1-2 11' 0" 1 3/4" x 9 1/2" 1.55E TimberStrand LSL 2 2TSHd1-2BBOHd1-2BBOHd1-2BBOHd2-2BBOHd2-2Sheet:4OF4A complete Javelin® framing plan requires the Framer's Pocket GuideSee the Framer's Pocket Guide for Product Trademark InformationWEEKES FOREST PRODUCTS, INC. * 2600 COMO AVENUE651-644-9807 * ST. PAUL, MN 55108LIVE LOAD:TOTAL LOAD:40DEFLECTION:L/480 LIVEL/240 TOTALDRAWN BY:JLT52WIND/EXP.:N/ADATE:03.08.21Lack of proper bracing during construction can result in seriousaccidents. Observe the following guidelines:WARNING NOTES:WARNINGJoists are unstable until braced laterallyBracing Includes:BlockingHangersSheathingRim BoardStrut LinesRim JoistDO NOT stack buildingmaterials on unsheathedjoists. Stack only overbeams or walls.DO NOT walk on joiststhat are lying flat.DO NOT walk on joistsuntil braced.INJURY MAY RESULT.Weyerhaeuser, Microllam, Parallam, TimberStrand, TJI, TJ, and Trus Joist are registered trademarks ofWeyerhaeuser NR. © 2014 Weyerhaeuser NR Company. All rights reserved.1. All blocking, hangers, rim boards and rim joists at the end supports of the TJI® joists must be completely installed and properly nailed.2. Laterial strength, like braced end wall or an existing deck, must be established at the ends of the bay. This can also beaccomplished by a temporary or permanent deck (sheathing) fastened to the first 4 feet of joists at the end of the bay.3. Safety bracing of 1x4 (minimum) must be nailed to a braced end wall or sheathed area (as in note 2) and to each joist.Without this bracing, buckling sideways or rollover is highly probable under light construction loads - such as a worker orone layer of unnailed sheathing.5. Ends of cantilevers require safety bracing on both the top and bottom flanges.6. The flanges must remain straight within 1/2" from true alignment.4. Sheathing must be completely attached to each TJI® joist before additional loads can be placed on the system.User Defined Point LoadUser Defined Line LoadUser Defined Area LoadBeam By OthersPost By OthersConstruction Detail Callout(See Framer's Pocket Guide)Excessive Point Load(WARNING: Member design did notinclude this load. Special considerationis required by the designer of record.)Required Bearing Length(Only placed at insufficient bearinglocations.)BBOPBOPL: 12KSymbol LegendLayout Start LocationSCALE: 1/4" = 1'-0"This layout is intended for the use of Trus Joist® engineered woodproducts only. The subsƟtuƟon of other engineered wood products withthis layout isNOT PERMITTED. Please idenƟfy the TJI®, TimberStrand®LSL, Microllam® LVL, and Parallam® PSL stamps on the product to ensurethat this layout is valid for the products actually installed. © © I hereby certify that this plan, specification, or reportwas prepared by me or under my direct supervisionand that I am a duly licensed Professional Engineerunder the laws of the State of Minnesota. Print Name: _______________________________ Signature: ________________________________ Date: ____________________ License # _______ James P. Shedlauskas 417767/15/21 ▪ ▪ ▪ ▪▪▪▪▪▪▪ ▪ ▪▪▪▪▪ ▪▪ ▪ ▪▪▪ I hereby certify that this plan, specification, or reportwas prepared by me or under my direct supervisionand that I am a duly licensed Professional Engineerunder the laws of the State of Minnesota. Print Name: _______________________________ Signature: ________________________________ Date: ____________________ License # _______ James P. Shedlauskas 417767/15/21 BWPs Above *FLIPPED* I hereby certify that this plan, specification, or reportwas prepared by me or under my direct supervisionand that I am a duly licensed Professional Engineerunder the laws of the State of Minnesota. Print Name: _______________________________ Signature: ________________________________ Date: ____________________ License # _______ James P. Shedlauskas 417767/15/21 PlotID Length Product Plies Net Qty TSHd1-2 11' 0" 1 3/4" x 9 1/2" 1.55E TimberStrand LSL 2 2 *FLIPPED* I hereby certify that this plan, specification, or reportwas prepared by me or under my direct supervisionand that I am a duly licensed Professional Engineerunder the laws of the State of Minnesota. Print Name: _______________________________ Signature: ________________________________ Date: ____________________ License # _______ James P. Shedlauskas 417767/15/21 I hereby certify that this plan, specification, or reportwas prepared by me or under my direct supervisionand that I am a duly licensed Professional Engineerunder the laws of the State of Minnesota. Print Name: _______________________________ Signature: ________________________________ Date: ____________________ License # _______ James P. Shedlauskas 417767/15/21 40,000 X X 40,000 40,000 3000 3000 3000 40,000 40,000 13.33 13.33 88000 1440 1440 .48 .48 .52 .52 6.9 2.9 280 415 415 4266 639 639 -224 190 6 Bedrooms 95 4266 SF 7404 204th Street West Date Certificate Posted X Passive (No Fan ) Active (With fan and monometer or other system monitoring device) Location (or future location) of Fan: Other Please Describe Here X R-15 X X X R-20 X R-20 X R-20 X R-49 X R-49 X R-30 X R-30 X Not applicable, all ducts located in conditioned space 8 X Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS:88,000 Capacity in Gallons:Other, describe: AFUE or HSPF% 93% Cfm's " round duct OR " metal duct Not required per mech. code X Passive X Low: Other, describe: Low: Location of fan(s), describe: Cfm's 6 " round duct OR " metal duct Duct system air tightness: Heating or Cooling Ducts Outside Conditioned Spaces Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area Describe other insulated areas Building envelope air tightness: Windows & Doors Average U-Factor (excludes skylights and one door ) U: 0.31 Solar Heat Gain Coefficient (SHGC):0.29 R-value MECHANICAL SYSTEMS Make-up Air Select a Type Appliances Heating System Domestic Water Heater Cooling System Nat Gas Nat Gas Elect GPVL-50 13ACXN36-230 Fuel Type Manufacturer Lennox AOSmith Lennox Model ML193UH090XE36B 13 Location of duct or system: Rating or Size 50 Output in Tons:3 Efficiency SEER /EER Residential Load Calculation Heating Loss Heating Gain Cooliing 65,992 26,128 29,763 MECHANICAL VENTILATION SYSTEM Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Combustion Air Select a Type Select Type Heat Recover Ventilator (HRV) Capacity in cfms:190 MN License Number Lennar 1413 THERMAL ENVELOPE RADON CONTROL SYSTEM Type: Check All That Apply Insulation Location Total R-Value of all Types of InsulationNon or Not ApplicableFiberglass, BlownFiberglass, BattsFoam, Closed CellFoam Open CellMineral FiberboardRigid, Extruded PolystyreneRigid, IsocynurateNew Construction Energy Code Compliance Certificate Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel.1/19/2022 Mailing Address of the Dwelling or Dwelling Unit City Lakeville7404 204th Street West Name of Residential Contractor Below Entire Slab Foundation Wall Perimeter of Slab on Grade Rim Joist (1st Floor) Rim Joist (2nd Floor+) Wall Ceiling, flat Interior R5 + R10 Exterior Interior Interior Balanced Ventilation capacity in cfms:Mech Room Capacity continuous ventilation rate in cfms: Total ventilation (intermittent + continuous) rate in cfms: 95 High: Energy Recover Ventilator (ERV) Capacity in cfms:High: Location of duct or system: 000000Builders Associaton of Minnesota version 101014 NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. New residential building permits WILL NOT be issued without this completed form. Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ Primary Contact: _________________________________________________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Description of Land Disturbing Activity: _____________________________________________________ NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___ If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an erosion and sediment control plan MUST be submitted with the residential building permit application. “The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.”(NPDES Construction Stormwater Permit, MPCA) “The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA) Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name of Person: ________________________________Company: _______________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: ________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots. No land disturbing activity may begin until a residential building permit has been issued. I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 7404 204th Street West U.S. Home Corp d/b/a Lennar Jesse Schwarzrock 612-346-2648 Jesse.Schwarzrock@Lennar.com Residential Development 57174 Chad Johnson Stantec 651-325-6860 chad.johnson@stantec.com University of Minnesota 5/31/23 1/19/2022Kurt NiskaDigitally signed by Kurt Niska Date: 2022.01.19 15:24:55 -06'00' 01/24/22 X X