Loading...
HomeMy WebLinkAboutLA199445 - Approved Vuthy Phan PE Letter wStamp 02 03 2022Structural Engineering Letter Date: 02/03/2022 Project Name: Vuthy Phan Project Address: 21381 Hytrail Cir, Lakeville(MN), MN, 55044 Contractor : Wolf River Electric Contractor Address : 101 Isanti Parkway NE, Isanti, MN 55040 Attn : To Whom It May Concern A Field observation of the condition of the existing framing system was performed by an audit team from Wolf River Electric. From the Field observation of the property, the existing roof structure observed as follows: Existing roof is supported by 2 x 4 @ 24" rafters at the solar array. The rafters are sloped at approximately 27 degree and have maximum projected horizontal span of 7 feet in between load bearing supports. Design Criteria Applicable codes: 2020 Minnesota Building Code (2018 IBC) ASCE 7-16 Ground Snow Load: 50 psf Roof Dead Load: 20 psf Wind speed: 125 mph Risk Category: II Date Certified and Signed: 02/03/2022 I certify that the capacity of the structural roof framing that directly supports the additional gravity loading due to the solar panel supports and modules had been reviewed and determined to meet or exceed the requirements in accordance with the Design Criteria. If you have any questions or concerns please contact us, Engineerinc.io, 303 N Glenoaks Blvd Suite 200 Burbank, CA 91502 (747) 333 - 5991 new@engineerinc.io