LA199755 and LA199288 - Approved Complete Permit Application
RESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov Submit to: permits@lakevillemn.gov DAVID P BREZINSKI (651) 206-3341 X danielle.demarre@allenergysolar.com April, 2022April, 2022$8455 Rooftop PV solar installation. Lakeville MN 55044 19541 HAZEL NUT AVE RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: 1264 Energy Lane 55108 (651) 842-9404 Colin Buechel All Energy Solar 667674 St. Paul MN Installation of a flush mount solar array on the roof of the residence X Colin Buechel :(676+25( '(6,*1(1*,1((563& 100 GREAT OAKS BLVD. ͿSUITE 115 ALBANY Ϳ NEW YORK Ϳ 12203 :HVW6KRUH'HVLJQ(QJLQHHUVۅ*UHDW2DNV%OYGۅ6XLWHۅ$OEDQ\1<ۅ 6XEMHFW %UH]LQVNL5HVLGHQFH +D]HO1XW$YH /DNHYLOOH01 7R:KRP,W0D\&RQFHUQ 7KHIROORZLQJUHIHUHQFHVWKH%UH]LQVNL5HVLGHQFHLQ/DNHYLOOH01 ([LVWLQJURRIIUDPLQJ 5RRIV 3UHIDEULFDWHGHQJLQHHUHGZRRGWUXVVLV[DW´RF7KLVH[LVWLQJVWUXFWXUHLV FDSDEOHWRVXSSRUWDOOWKHORDGVLQGLFDWHGEHORZIRUWKLVSKRWRYROWDLFSURMHFW 5RRI/RDGLQJ SVIGHDGORDGPRGXOHVSOXVPRXQWLQJKDUGZDUH SVIJURXQGVQRZORDG SVIURRIPDWHULDOVSVI[SVIVKHDWKLQJSVIDVSKDOWVKLQJOHV ([SRVXUH&DWHJRU\%PSKZLQGVHF 7KLVLQVWDOODWLRQGHVLJQZLOOEHLQJHQHUDOFRQIRUPDQFHWRWKHPDQXIDFWXUHU¶VVSHFLILFDWLRQVDQGFRPSOLHV ZLWKDOODSSOLFDEOHODZVFRGHVDQGRUGLQDQFHVVSHFLILFDOO\WKH,QWHUQDWLRQDO%XLOGLQJ&RGH,%& DQG,QWHUQDWLRQDO5HVLGHQWLDO&RGH,5&LQFOXGLQJDOO01UHJXODWLRQVDQGDPHQGPHQWV7KHVSDFLQJ DQGIDVWHQLQJRIWKHPRXQWLQJEUDFNHWVLVWRKDYHDPD[LPXPRI´RFVSDQEHWZHHQPRXQWLQJEUDFNHWV VWDJJHUHGDQGVHFXUHGXVLQJ´GLDPHWHUFRUURVLYHUHVLVWDQWVWHHOODJEROWVDQGD´HPEHG 7KDQN\RX :HVWVKRUH'HVLJQ(QJLQHHUV -RKQ(LEHUW1LFRODV1LWWL3( 3URMHFW&RRUGLQDWRU3UHVLGHQW 7R $OO(QHUJ\6RODU )URQW6W &KLFRSHH0$ 'DWH)HEUXDU\ 5HI LICENSED PROFESSIONAL ENGINEERNICOLAS A . NI TTISTATE OF M I N NESO TA54597 EXP. 6/30/2022 COMPANY INFORMATION CLIENT INFORMATION SYSTEM DETAILS PROJECT-PAGE TITLE ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM PAGE NUMBER A0 REVISIONS LAST: 02/3/22 AH AZIMUTH NOTES: 1. (32) ENPHASE IQ7+ INVERTER(S) 2. ARRAY 1: 39° TILT, 173° AZIMUTH 3. ARRAY 2: 34° TILT, 263° AZIMUTH 6. ARRAY 3: (Array 3 Tilt)° TILT, (Array 3 Azimuth)° AZIMUTH 7. ARRAY 4: (Array 4 Tilt)° TILT, (Array 4 Azimuth)° AZIMUTH COVER PAGE DAVID BREZINSKI 19541 HAZEL NUT AVE LAKEVILLE, MN 55044 PO 43862 N HAZEL NUT AVE ARRAY 1 ARRAY 2 REC 365 BOB 32 Flush Roof Mount 11.680 Panel Type # of Panels System Size (kW) COMPANY INFORMATION CLIENT INFORMATION SYSTEM DETAILS PROJECT-PAGE TITLE ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM PAGE NUMBER A1 REVISIONS LAST: 02/3/22 AH NOTES: 1. ELEVATIONS MAY VARY DEPENDING ON GROUND ELEVATION BUT ARE DRAWN TO THE BEST OF OUR ABILITY 2. 2x4 TRUSS 24" OC ELEVATION DRAWINGS DAVID BREZINSKI 19541 HAZEL NUT AVE LAKEVILLE, MN 55044 PO 43862 SETBACKS: 18" FROM RIDGE 18" FROM BOTH SIDES OF VALLEY 36" FROM EDGE SOUTH ELEVATION WEST ELEVATION 10'-0"11'-0"16'-8"17'-7"19'-10"31'-5"23'-8"30'-2" COMPANY INFORMATION CLIENT INFORMATION SYSTEM DETAILS PROJECT-PAGE TITLE ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM PAGE NUMBER A2 REVISIONS LAST: 02/3/22 AH *STRINGING TO BE DETERMINED ON SITE 2x4 TRUSS 24" OC RAIL AND STRINGING DIAGRAM AZIMUTH <aCustName(s)> <aCustAddress1> <aCustAddress2> <aCustAddress3> PO <aCustPONumber> N DAVID BREZINSKI 19541 HAZEL NUT AVE LAKEVILLE, MN 55044 PO 43862 SNR FLASHING 2x4 TRUSS 24" OC (32) LG 365N1K-A6 MODULES (32) ENPHASE IQ7+ INVERTER(S) CIRCUITS: (2) CIRCUIT(S) OF 11 MICROS (1) CIRCUIT(S) OF 10 MICROS ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) MICROS ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) MICROS ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) MICROS SNAP-N-RACK MOUNTING HARDWARE: 1. (70) L-FEET 2. (10) RAIL SPLICES 3. CLAMPS (54) MIDCLAMPS (20) ENDCLAMPS 4. RAIL LENGTHS: (16) 168" RAILS ARRAY 1 ARRAY 2 MAX CIRCUIT LENGTH (120/240V) 15A BREAKER 20A BREAKER ENPHASE IQ7 12 16 ENPHASE IQ7+9 13 ENPHASE IQ7X 9 12 ENPHASE IQ7A 8 11 RT MINI ATTACHMENTS COMPANY INFORMATION CLIENT INFORMATION SYSTEM DETAILS PROJECT-PAGE TITLE ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM PAGE NUMBER A3 REVISIONS LAST: 02/3/22 AH AZIMUTH ACCOUNT: 51-9273198-3 PREMISE: 304183087 METER: 59330715 CASE ID: 04445808 SITE MAP N DAVID P BREZINSKI 19541 HAZEL NUT AVE LAKEVILLE, MN 55044 PO 43862 NOTES: 1. (32) ENPHASE IQ7+ INVERTER(S) = 9.28kW AC 2. ARRAY 1: 173° AZIMUTH, 39° TILT (16) LG 365W = 5.84kW 3. ARRAY 2: 263° AZIMUTH, 34° TILT (16) LG 365W = 5.84kW 4. ARRAY 3: (Array 3 Azimuth)° AZIMUTH, (Array 3 Tilt)° TILT ((Array 3 Panel Qty)) LG 365W = (Array 3 kW)kW 5. ARRAY 4: (Array 4 Azimuth)° AZIMUTH, (Array 4 Tilt)° TILT ((Array 4 Panel Qty)) LG 365W = (Array 4 kW)kW 1 2 3 4 5 6 CALL-OUTS: 1: SOLAR PANELS 2: INVERTERS 3: ENPHASE IQ COMBINER PANEL 4: UTILITY AC DISCONNECT 5: PV PRODUCTION METER 6: FUSED AC DISCONNECT 7: BI-DIRECTIONAL METER 8: MAIN ELECTRIC SERVICE DISTANCESSOLAR PANELS - INVERTERS: 5' MAX INVERTERS - IQ COMBINER PANEL: 50' MAX IQ COMBINER PANEL - UTILITY AC DISCONNECT: 2' UTILITY AC DISCONNECT - PV PRODUCTION METER: 2' PV PRODUCTION METER - FUSED AC DISCONNECT: 2' FUSED AC DISCONNECT - BI-DIRECTIONAL METER: 2' BI-DIRECTIONAL METER - MAIN ELECTRIC SERVICE: 5' <10' 194TH ST W ≈ 230'HAZEL NUT AVEARRAY 1 ARRAY 2 8 LABELS LOCATED ON PV PRODUCTION METER, BI- DIRECTIONAL METER, AC DISCONNECT(S), INVERTER(S), AND APPROPRIATE LABELS ON MAIN ELECTRIC SERVICE. ALL LABELS ARE PERMANENT, WEATHERPROOF, AND DURABLE THERE ARE NO CLEARANCE ISSUES DUE TO OVERHEAD POWERLINES. NOTES: 1. LOCATION OF SERVICE PANEL AND ELECTRICAL EQUIPMENT ARE SHOWN. FINAL LOCATION MAY CHANGE 2. LOCATION OF SERVICE PANEL AND ADDITIONAL ELECTRICAL EQUIPMENT NOT DRAWN TO SCALE 3. PV INTERCONNECTION IS A SECONDARY INTERCONNECTION 4. AC DISCONNECT AND PRODUCTION METER WITHIN 10' OF MAIN SERVICE METER/BI-DIRECTIONAL METER. 24/7 UNESCORTED KEYLESS ACCESS TO BE PROVIDED FOR UTILITY AC DISCONNECT, PV PRODUCTION METER, & BI-DIRECTIONAL METER. 5. PV EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690 AND POSTED WITH APPLICABLE WARNINGS, SIGNAGE, AND PLAQUES PER NEC 705-10, 690-17, & 690-64 (b)(5). 1 2 7 3'-0"18" SETBACKS PER FIRE CODE COMPANY INFORMATION CLIENT INFORMATION SYSTEM DETAILS PROJECT-PAGE TITLE ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM PAGE NUMBER A4 REVISIONS LAST: 02/3/22 AH *DISTANCES NOT TO SCALE NOTES: 1. DESIGN MEETS NEC CODE AND SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690 AND POSTED WITH APPLICABLE WARNINGS, SIGNAGE, AND PLAQUES PER NEC 705-10, 690- 17, & 690-64 (b) (5) 2. SOLAR MODULES, INVERTERS, AND CORRESPONDING ELECTRICAL EQUIPMENT ARE LISTED. 3. INVERTERS ARE UL 1741 LISTED 4. PV INTERCONNECTION IS A SECONDARY INTERCONNECTION SYSTEM SIZE: 11.68kW DC MAXIMUM POWER: 9.28 kW AC OPERATING VOLTAGE: 120/240V MAXIMUM CURRENT: 38.72A ACCOUNT: 51-9273198-3 PREMISE: 304183087 METER: 59330715 CASE ID: 04445808 ELECTRICAL LINE DIAGRAM TO UTILITY DAVID P BREZINSKI 19541 HAZEL NUT AVE LAKEVILLE, MN 55044 PO 43862 AC DC FUSED AC DISCONNECT VISIBLE-OPEN TYPE, LOCKABLE, READILY ACCESSIBLE 1 PHASE, 60A, 120/240V SEE LABEL(S) 10, 14, 15, 16, 20, 35 ON FOLLOWING PAGES 2' EXISTING CONDUIT 5' MAX 120/240V 200A RATED BUS 200A MAIN SQUARE D LOAD PANEL SEE LABEL(S) 18 ON FOLLOWING PAGES LG LG365N1K-A6 RATED POWER AT STC:365W VMP:35.1V IMP:10.41A VOC:41.8V ISC:10.92A MODULE DETAILS: (32)50AXCEL ENERGY BI-DIRECTIONAL METER 120/240V, 1-PHASE, 3-WIRE SEE LABEL(S) 41, 42 ON FOLLOWING PAGES (32) LG 365N1K-A6 11.68kW (32) ENPHASE IQ7+ 120/240V (2) CIRCUIT(S) OF 11 (20A EA) (1) CIRCUIT(S) OF 10 (20A EA) ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) ([Amps] (If Enphase. Based on 15 or 20A breakers)A EA) ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) ([Amps] (If Enphase. Based on 15 or 20A breakers)A EA) ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) ([Amps] (If Enphase. Based on 15 or 20A breakers)A EA) INVERTER DETAILS: ENPHASE IQ7PLUS-72-2-US Rating: 290 W CEC Weighted Efficiency: 97 % Max DC Voltage: 60.V V Max AC Output Current: 1.21 A Nominal Voltage Range: 240V / 211-264V (1-Phase) Nominal Frequency: 60 Hz50' MAX 3/4" EMT: (6) #10 THWN (1) #10 GROUND 2' MAX 3/4" EMT: (2) #6 THWN (1) #6 NEUTRAL (1) #10 GROUND 2' MAX 3/4" EMT: (2) #6 THWN (1) #6 NEUTRAL [%]% VOLTAGE DROP [Trench distance]' MAX [Minimum 1]" PVC: (2) #[wire size] THWN (1) #10 NEUTRAL (1) #10 GROUND 2' MAX 1" PVC: (2) #6 THWN (1) # 6 NEUTRAL ENPHASE IQ COMBINER PANEL 120/240V 125A 1 PHASE PLACARD INDICATING "NO LOAD TO BE SERVED" SEE LABEL(S) 16, 18, 24 ON FOLLOWING PAGES POINT OF COMMON COUPLING LINETAP INSIDE MAIN ELECTRICAL PANEL VIA UL-LISTED POLARIS LUGS. INSTALLATION IS A SECONDARY INTERCONNECTION.UTILITY AC DISCONNECT VISIBLE-OPEN TYPE, LOCKABLE, READILY ACCESSIBLE 1 PHASE, 60A, 120/240V SEE LABEL(S) 10, 14, 15, 16, 20, 35 ON FOLLOWING PAGES (REFERENCE POINT OF APPLICABILITY) TEST AND VERIFICATION FEATURES CONDUCTED HERE PER TEST PROCEDURE. ALL TESTING TO BE CONDUCTED WITH CUSTOMER OWNED EQUIPMENT XCEL ENERGY PRODUCTION METER 120/240V, 200A WITH BYPASS 1-PHASE, 3-WIRE SEE LABEL(S) 21 ON FOLLOWING PAGES LINE LOAD 2' MAX 3/4" EMT: (2) #6 THWN (1) #6 NEUTRAL COMPANY INFORMATION CLIENT INFORMATION SYSTEM DETAILS PROJECT-PAGE TITLE ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM PAGE NUMBER A5 REVISIONS LAST: 02/3/22 AH LABELS ARE WEATHERPROOF, DURABLE, PERMANENTLY MOUNTED, AND COMPLY WITH NEC 690 ACCOUNT: 51-9273198-3 PREMISE: 304183087 METER: 59330715 CASE ID: 04445808 LABELS DAVID P BREZINSKI 19541 HAZEL NUT AVE LAKEVILLE, MN 55044 PO 43862 PHOTOVOLTAIC AC DISCONNECT MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: P H O T O V O L T A I C A C D I S C O N N E C T MAIN PHOTOVOLTAIC SYSTEM DISCONNECT CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED ! WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM WARNING: PHOTOVOLTAIC POWER SOURCE WARNING! ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM 16 13 15 41 42 14 5: EXPOSED DC CONDUIT, JUNCTION BOXES, ECT. 8: 10 HOUSE METER 21 PV PRODUCTION METER TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS 35 MAXIMUM DC VOLTAGE OF PV SYSTEM 7 PHOTOVOLTAIC DC DISCONNECT 6 ! POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. WARNING PV SYSTEM CIRCUIT BREAKER IS BACKFED CAUTION 36 37 UTILITY AC DISCONNECT 20 NOTE: LABELS ARE FOR GENERAL REFERENCE. NOT ALL LABELS ARE USED FOR EVERY INSTALLATION. INTERCONNECTION DISCONNECT SWITCH 17 COMPANY INFORMATION CLIENT INFORMATION SYSTEM DETAILS PROJECT-PAGE TITLE ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM PAGE NUMBER A6 REVISIONS LAST: 02/3/22 AH LABELS 2 LABELS ARE WEATHERPROOF, DURABLE, PERMANENTLY MOUNTED, AND COMPLY WITH NEC 690 ACCOUNT: 51-9273198-3 PREMISE: 304183087 METER: 59330715 CASE ID: 04445808 43 18 DAVID P BREZINSKI 19541 HAZEL NUT AVE LAKEVILLE, MN 55044 PO 43862 CAUTION:MULTIPLE SOURCES OF POWER: N All Energy Solar www.allenergysolar.com (800) 620-3370 SOLAR ARRAY PV COMBINER PANEL HOUSE SERVICE DISCONNECT (BASEMENT) MAIN PV DISCONNECT INTERCONNECTION DISCONNECT SWITCH 17 DUAL POWER SOURCE PHOTOVOLTAIC CIRCUIT Operating Voltage: 120/240 Maximum Current: 38.72 Amps Maximum Power: 9.28 KW MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC CONVERTER (IF INSTALLED) 22 24 NOTICEPV COMBINER PANEL ONLY NO LOADS EMERGENCY DISCONNECT SERVICE DISCONNECT 15 LG365N1K-A6 About LG Electronics USA, Inc. LG Electronics is a global leader in electronic products in the clean energy markets by offering solar PV panels and energy storage systems. The company first embarked on a solar energy source research program in 1985, supported by LG Group’s vast experience in the semi-conductor, LCD, chemistry and materials industries. In 2010, LG Solar successfully released its first MonoX® series to the market, which is now available in 32 countries. The NeON® (previous MonoX® NeON), NeON®2, NeON®2 BiFacial won the “Intersolar AWARD” in 2013, 2015 and 2016, which demonstrates LG’s leadership and innovation in the solar industry. 60 When you go solar, ask for the brand you can trust: LG Solar 365W Features Enhanced Performance Warranty LG NeON® 2 Black has an enhanced performance warranty. After 25 years, LG NeON® 2 Black is guaranteed at least 90.6% of initial performance. Roof Aesthetics LG NeON® 2 Black has been designed with aesthetics in mind using thinner wires that appear all black at a distance. Solid Performance on Hot Days LG NeON® 2 Black performs well on hot days due to its low temperature coefficient. 25-Year Limited Product Warranty The NeON® 2 Black is covered by a 25-year limited product warranty. In addition, up to $450 of labor costs will be covered in the rare case that a module needs to be repaired or replaced. yrs25 Warranty The LG NeON® 2 is LG’s best selling solar module and one of the most powerful and versatile modules on the market today. The cells are designed to appear all-black at a distance, and the performance warranty guarantees 90.6% of labeled power output at 25 years. I-V Curves General Data Cell Properties (Material/Type)Monocrystalline/N-type Cell Maker LG Cell Configuration 60 Cells (6 x 10) Number of Busbars 12EA Module Dimensions (L x W x H)1,740mm x 1,042mm x 40 mm Weight 18.6 kg Glass (Material)Tempered Glass with AR coating Backsheet (Color)Black Frame (Material)Anodized Aluminium Junction Box (Protection Degree)IP 68 with 3 Bypass Diodes Cables (Length)1,100mm x 2EA Connector (Type/Maker)MC 4/MC Electrical Properties (NMOT) Model LG365N1K-A6 Maximum Power (Pmax)[W]274 MPP Voltage (Vmpp)[V]33.0 MPP Current (Impp)[A]8.30 Open Circuit Voltage (Voc)[V]39.4 Short Circuit Current (Isc)[A]8.78 Temperature Characteristics NMOT*[°C] 42 ± 3 Pmax [%/°C]-0.35 Voc [%/°C]-0.26 Isc [%/°C] 0.03 *NMOT (Nominal Module Operating Temperature): Irradiance 800 W/m2, Ambient temperature 20°C, Wind speed 1 m/s, Spectrum AM 1.5 LG365N1K-A6 LG Electronics USA, Inc.Solar Business Division2000 Millbrook DriveLincolnshire, IL 60069 www.lg-solar.com Product specifications are subject to change without notice. LG365N1K-A6_AUS.pdf 011821 © 2021 LG Electronics USA, Inc. All rights reserved. 1042.0 / 41.0 (Size of Short Side)320.0 / 12.61002.0 / 39.4 (Distance between Grounding & Mounting Holes) 175.0 / 6.9 1100 / 43.3 Cable Length 40.0 / 1.57 105.0 / 4.1220.0 / 8.616 - 8.0 x 3.0 / 0.3 x 0.1 Drain Holes 8 - Ø4.3 / 0.2 Grounding Holes 8 - 8.5 x 12.0 / 0.3 x 0.5 Mounting Holes Junction Box 1100.0 / 43.3 (Distance between Mounting Holes)1300.0 / 51.2 (Distance between Mounting Holes)1740.0 / 68.5 (Size of Long Side)200W 400W 600W 800W 1000W Voltage [V]Current [A]12.0 10.0 8.0 6.0 4.0 2.0 0.0 0.0 10.05.0 20.015.0 30.025.0 45.040.035.0 Operating Conditions Operating Temperature [°C] -40 ~+85 Maximum System Voltage [V]1,000 (UL/IEC) Maximum Series Fuse Rating [A]20 Mechanical Test Load* (Front)[Pa/psf]5,400 Mechanical Test Load* (Rear)[Pa/psf]4,000 Mechanical Test Loads 6,000Pa/5,400Pa based on IEC 61215:2005 *Based on IEC 61215-2 : 2016 (Test Load = Design Load x Safety Factor (1.5)) Packaging Configuration Number of Modules per Pallet [EA]25 Number of Modules per 40' Container [EA]650 Number of Modules per 53’ Container [EA]850 Packaging Box Dimensions (L x W x H)[mm]1,790 x 1,120 x 1,213 Packaging Box Dimensions (L x W x H)[in]70.5 x 44.1 x 47.8 Packaging Box Gross Weight [kg]500 Packaging Box Gross Weight [lb]1,102 Dimensions (mm/inch) Certifications and Warranty Certifications* IEC 61215-1/-1-1/2 : 2016, IEC 61730-1/2 : 2016, UL 61730-1 : 2017, UL 61730-2 : 2017 ISO 9001, ISO 14001, ISO 50001 OHSAS 18001 Salt Mist Corrosion Test IEC 61701:2012 Severity 6 Ammonia Corrosion Test IEC 62716:2013 Module Fire Performance Type 2 (UL 61730) Fire Rating Class C (UL 790, ULC/ORD C 1703) Solar Module Product Warranty 25 Year Limited Solar Module Output Warranty Linear Warranty* *Improved: 1st year 98.5%, from 2-24th year: -0.33%/year down, 90.6% at year 25 *STC (Standard Test Condition): Irradiance 1000 W/m2, cell temperature 25°C, AM 1.5 Measurement Tolerence of Pmax: 3%+- Electrical Properties (STC*) Model LG365N1K-A6 Maximum Power (Pmax)[W]365 MPP Voltage (Vmpp)[V]35.1 MPP Current (Impp)[A]10.41 Open Circuit Voltage (Voc 5%)[V]41.8 Short Circuit Current (Isc 5%)[A]10.92 Module Efficiency [%]20.1 Power Tolerance [%]0 ~ +3 +- +- The high-powered smart grid-ready Enphase IQ 7 Micro™ and Enphase IQ 7+ Micro™ dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy™, Enphase IQ Battery™, and the Enphase Enlighten™ monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Enphase IQ 7 and IQ 7+ Microinverters To learn more about Enphase offerings, visit enphase.com Data SheetEnphase MicroinvertersRegion: AMERICAS Easy to Install • Lightweight and simple • Faster installation with improved, lighter two-wire cabling • Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable • Optimized for high powered 60-cell and 72-cell* modules • More than a million hours of testing • Class II double-insulated enclosure • UL listed Smart Grid Ready • Complies with advanced grid support, voltage and frequency ride-through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) * The IQ 7+ Micro is required to support 72-cell modules. 1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility.3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com © 2018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. 2018-05-24 INPUT DATA (DC) IQ7-60-2-US / IQ7-60-B-US IQ7PLUS-72-2-US / IQ7PLUS-72-B-US Commonly used module pairings¹235 W - 350 W +235 W - 440 W + Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V - 37 V 27 V - 45 V Operating range 16 V - 48 V 16 V - 60 V Min/Max start voltage 22 V / 48 V 22 V / 60 V Max DC short circuit current (module Isc)15 A 15 A Overvoltage class DC port II II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal (L-L) voltage/range²240 V / 211-264 V 208 V / 183-229 V 240 V / 211-264 V 208 V / 183-229 V Maximum continuous output current 1.0 A (240 V)1.15 A (208 V)1.21 A (240 V)1.39 A (208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47 - 68 Hz 47 - 68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A (L-L) branch circuit³16 (240 VAC)13 (208 VAC)13 (240 VAC)11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Power factor (adjustable)0.7 leading ... 0.7 lagging 0.7 leading ... 0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 97.6 %97.6 %97.5 %97.3 % CEC weighted efficiency 97.0 %97.0 %97.0 %97.0 % MECHANICAL DATA Ambient temperature range -40ºC to +65ºC Relative humidity range 4% to 100% (condensing) Connector type (IQ7-60-2-US & IQ7PLUS-72-2-US)MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter) Connector type (IQ7-60-B-US & IQ7PLUS-72-B-US)Friends PV2 (MC4 intermateable). Adaptors for modules with MC4 or UTX connectors:- PV2 to MC4: order ECA-S20-S22- PV2 to UTX: order ECA-S20-S25 Dimensions (WxHxD)212 mm x 175 mm x 30.2 mm (without bracket) Weight 1.08 kg (2.38 lbs) Cooling Natural convection - No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environmental category / UV exposure rating NEMA Type 6 / outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options.Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA)UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer’s instructions. Enphase IQ 7 and IQ 7+ Microinverters DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, BONDING MID CLAMP 242-02050, 242-02051, 242-02052, 242-02053, 242-02054, 242-02055, 242-02056, 242-02057 D.Ryan Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902A REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL 800 2400 10+ LB-FT UL 2703, FILE E359313 0.16 - 0.18 OPTIONS: CLEAR / BLACK ANODIZED PARTS LIST DESCRIPTIONQTYITEM 5/16IN-18 SS HCS BOLT, LENGTH VARIES, CLEAR / BLACK11 5/16IN SS SPLIT LOCK WASHER, CLEAR / BLACK12 SNAPNRACK, BONDING MID CLAMP, CLEAR / BLACK13 SNAPNRACK, BONDING CHANNEL NUT14 SNAPNRACK, MID CLAMP SPRING, SS15 1 2 3 4 5 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, BONDING MID CLAMP 242-02050, 242-02051, 242-02052, 242-02053, 242-02054, 242-02055, 242-02056, 242-02057 D.Ryan Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902A REVISION: ALL DIMENSIONS IN INCHES X 1.75 1.50 .30 1.15 .91.16 .50 1.29 MID CLAMP PROPERTIES SKU BOLT LENGTH (X)FINISH 242-02050 2.25"CLEAR 242-02051 2.50"CLEAR 242-02052 2.75"CLEAR 242-02053 2.25"BLACK 242-02054 2.50"BLACK 242-02055 2.75"BLACK 242-02056 3.00"CLEAR 242-02057 3.00"BLACK .70 .32 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, ULTRA RAIL COMP KIT SEE BELOW mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL, RUBBER 405 UP, 788 DOWN, 236 SIDE 2006 UP, 4000 DOWN, 1070 SIDE 12 LB-FT UL 2703, FILE E359313; WIND-DRIVEN RAIN TEST FROM UL SUBJECT 2582 0.80 PARTS LIST DESCRIPTIONPART NUMBERQTYITEM SNAPNRACK, UMBRELLA LAG, TYPE 3, 4IN, SS242-9226611 SNAPNRACK, ULTRA FOOT FOR U FLASHING, SILVER / BLACK242-01219, 242-0122012 SNAPNRACK, COMP FLASHING, 9IN X 12IN, SILVER / BLACK ALUM232-01375, 232-0137613 3 1 2 2 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, ULTRA RAIL COMP KIT SEE BELOW mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: ALL DIMENSIONS IN INCHES 11.75 3.25 8.75 .45 6.75 1.00 4.20 .30 3.25 1.00 1.00SLOT 1.50 2.781.78 1.50 .38 .30 1.37 1.62 UMBRELLA L FOOT PROPERTIES SKU DESCRIPTION 242-01219 ULTRA RAIL UMBRELLA L FOOT, SILVER 242-01220 ULTRA RAIL UMBRELLA L FOOT, BLACK COMP FLASHING PROPERTIES SKU DESCRIPTION 232-01375 COMP FLASHING, 9" X 12", BLACK ALUM 232-01376 COMP FLASHING, 9" X 12", SILVER ALUM .35 1.80 105° DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, UNIVERSAL END CLAMP 242-02215 D.Ryan Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902A REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL 800 2400 10+ LB-FT UL 2703, FILE E359313 0.24 OPTIONS: PARTS LIST DESCRIPTIONQTYITEM SNAPNRACK END CLAMP UNIVERSAL WAVE11 SNAPNRACK, UNIVERSAL END CLAMP WEDGE12 5/16IN X 3/4IN SS FLAT WASHER13 BOLT, HEX CAP, 5/16IN-18 X 1-1/2IN, SS14 SNAPNRACK UEC PULL STRAP15 1 4 3 2 5 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, UNIVERSAL END CLAMP 242-02215 D.Ryan Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902A REVISION: ALL DIMENSIONS IN INCHES .98 1.73 1.50 .60 35°.8554° .90 4°1.07 .29 .52 1.00 1.56 .96 .95 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, UR-40 RAIL 232-02449, 232-02450, 232-02451 mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM N/A N/A N/A LB-FT UL 2703, FILE E359313 5.85 OPTIONS: CLEAR / BLACK ANODIZED MILL FINISH BUNDLES OF 144 BOXES OF 8 ALL DIMENSIONS IN INCHES UR-40 RAIL PROPERTIES SKU FINISH 232-02449 MILL 232-02450 CLEAR 232-02451 BLACK 1.624 1.500 CENTROID .750 .832 .792 EQUIVALENT PROPERTIES A0.357 in² Ixx 0.125 in⁴ Iyy 0.132 in⁴ Sx (TOP)0.150 in³ Sx (BOT)0.158 in³ Sy (LEFT)0.175 in³ Sy (RIGHT)0.175 in³