Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LA199752 - Approved BUILDING PERMIT APPLICATION
RESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov Submit to: permits@lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: :(676+25( '(6,*1(1*,1((563& 100 GREAT OAKS BLVD. ͿSUITE 115 ALBANY Ϳ NEW YORK Ϳ 12203 :HVW6KRUH'HVLJQ(QJLQHHUVۅ*UHDW2DNV%OYGۅ6XLWHۅ$OEDQ\1<ۅ 6XEMHFW :LEEHQV5HVLGHQFH +LELVFXV$YH /DNHYLOOH01 7R:KRP,W0D\&RQFHUQ 7KHIROORZLQJUHIHUHQFHVWKH:LEEHQV5HVLGHQFHLQ/DNHYLOOH01 ([LVWLQJURRIIUDPLQJ 5RRIV3UHIDEULFDWHGHQJLQHHUHGZRRGWUXVVLV[DW´RF7KLVH[LVWLQJVWUXFWXUHLV FDSDEOHWRVXSSRUWDOOWKHORDGVLQGLFDWHGEHORZIRUWKLVSKRWRYROWDLFSURMHFW 5RRI/RDGLQJ SVIGHDGORDGPRGXOHVSOXVPRXQWLQJKDUGZDUH SVIJURXQGVQRZORDG SVIURRIPDWHULDOVSVI[SVIVKHDWKLQJSVIDVSKDOWVKLQJOHV ([SRVXUH&DWHJRU\%PSKZLQGVHF 7KLVLQVWDOODWLRQGHVLJQZLOOEHLQJHQHUDOFRQIRUPDQFHWRWKHPDQXIDFWXUHU¶VVSHFLILFDWLRQVDQGFRPSOLHV ZLWKDOODSSOLFDEOHODZVFRGHVDQGRUGLQDQFHVVSHFLILFDOO\WKH,QWHUQDWLRQDO%XLOGLQJ&RGH,%& DQG,QWHUQDWLRQDO5HVLGHQWLDO&RGH,5&LQFOXGLQJDOO01UHJXODWLRQVDQGDPHQGPHQWV7KHVSDFLQJ DQGIDVWHQLQJRIWKHPRXQWLQJEUDFNHWVLVWRKDYHDPD[LPXPRI´RFVSDQEHWZHHQPRXQWLQJEUDFNHWV VWDJJHUHGDQGVHFXUHGXVLQJ´GLDPHWHUFRUURVLYHUHVLVWDQWVWHHOODJEROWVDQGD´HPEHG 7KDQN\RX :HVWVKRUH'HVLJQ(QJLQHHUV -RKQ(LEHUW1LFRODV1LWWL3( 3URMHFW&RRUGLQDWRU3UHVLGHQW 7R $OO(QHUJ\6RODU )URQW6W &KLFRSHH0$ 'DWH)HEUXDU\ 5HI LICENSED PROFESSIONAL ENGINEERNICOLAS A . NI TTISTATE OF M I N NE SO TA54597 EXP. 6/30/2022 COMPANY INFORMATION CLIENT INFORMATION SYSTEM DETAILS PROJECT-PAGE TITLE ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM PAGE NUMBER A0 REVISIONS LAST: 01/28/22 AH AZIMUTH NOTES: 1. (21) ENPHASE IQ7+ INVERTER(S) 2. ARRAY 1: 26° TILT, 180° AZIMUTH 3. ARRAY 2: 26° TILT, 180° AZIMUTH 4. ARRAY 3: 26° TILT, 90° AZIMUTH 5. ARRAY 4: (Array 4 Tilt)° TILT, (Array 4 Azimuth)° AZIMUTH COVER PAGE KIM WIBBENS 17416 HIBISCUS AVE LAKEVILLE, MN 55044 PO 51077 N HIBIS C U S A V E ARRAY 1 ARRAY 2 ARRAY 3 LG 370 21 FLUSH ROOF MOUNT 7.77 Panel Type # of Panels System Size (kW) COMPANY INFORMATION CLIENT INFORMATION SYSTEM DETAILS PROJECT-PAGE TITLE ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM PAGE NUMBER A1 REVISIONS LAST: 01/28/22 AH NOTES: 1. ELEVATIONS MAY VARY DEPENDING ON GROUND ELEVATION BUT ARE DRAWN TO THE BEST OF OUR ABILITY 2. 2x4 TRUSS 24" OC ELEVATION DRAWINGS KIM WIBBENS 17416 HIBISCUS AVE LAKEVILLE, MN 55044 PO 51077 SETBACKS: 18" FROM RIDGE 18" FROM BOTH SIDES OF VALLEY 36" FROM EDGE SOUTH ELEVATION EAST ELEVATION 17'-3"25'-7"20'-6"24'-6"10'-0"11'-1"17'-7"18'-9"17'-3"18'-6"24'-6"25'-7" COMPANY INFORMATION CLIENT INFORMATION SYSTEM DETAILS PROJECT-PAGE TITLE ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM PAGE NUMBER A2 REVISIONS LAST: 01/28/22 AH *STRINGING TO BE DETERMINED ON SITE 2x4 TRUSS 24" OC RAIL AND STRINGING DIAGRAM AZIMUTH <aCustName(s)> <aCustAddress1> <aCustAddress2> <aCustAddress3> PO <aCustPONumber> N KIM WIBBENS 17416 HIBISCUS AVE LAKEVILLE, MN 55044 PO 51077 SNR FLASHING 2x4 TRUSS 24" OC (21) LG 370N1K-A6 MODULES (21) ENPHASE IQ7+ INVERTER(S) CIRCUITS: (1) CIRCUIT(S) OF 10 MICROS (1) CIRCUIT(S) OF 11 MICROS ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) MICROS ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) MICROS ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) MICROS SNAP-N-RACK MOUNTING HARDWARE: 1. (71) L-FEET 2. (6) RAIL SPLICES 3. CLAMPS (22) MIDCLAMPS (40) ENDCLAMPS 4. RAIL LENGTHS: (17) 172" RAILS ARRAY 1 ARRAY 2 ARRAY 3 MAX CIRCUIT LENGTH (120/240V) 15A BREAKER 20A BREAKER ENPHASE IQ7 12 16 ENPHASE IQ7+9 13 ENPHASE IQ7X 9 12 ENPHASE IQ7A 8 11 RT MINI ATTACHMENTS COMPANY INFORMATION CLIENT INFORMATION SYSTEM DETAILS PROJECT-PAGE TITLE ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM PAGE NUMBER A3 REVISIONS LAST: 01/28/22 AH AZIMUTH ACCOUNT: 200002171015 PREMISE: 92415 METER: 1ND89986796 SITE MAP N KIM M WIBBENS 17416 HIBISCUS AVE LAKEVILLE, MN 55044 PO 51077 NOTES: 1. (21) ENPHASE IQ7+ INVERTER(S) = 6.09kW AC 2. ARRAY 1: 180° AZIMUTH, 26° TILT (9) LG 370W = 3.33kW 3. ARRAY 2: 180° AZIMUTH, 26° TILT (9) LG 370W = 3.33kW 4. ARRAY 3: 90° AZIMUTH, 26° TILT (3) LG 370W = 1.11kW 5. ARRAY 4: (Array 4 Azimuth)° AZIMUTH, (Array 4 Tilt)° TILT ((Array 4 Panel Qty)) LG 370W = (Array 4 kW)kW NOTES: 1. LOCATION OF SERVICE PANEL AND ELECTRICAL EQUIPMENT ARE SHOWN. FINAL LOCATION MAY CHANGE 2. LOCATION OF SERVICE PANEL AND ADDITIONAL ELECTRICAL EQUIPMENT NOT DRAWN TO SCALE 3. PV INTERCONNECTION IS A SECONDARY INTERCONNECTION 4. AC DISCONNECT AND PRODUCTION METER IN READILY ACCESSIBLE LOCATION WITHIN 10' OF MAIN SERVICE METER/BI-DIRECTIONAL METER. 24/7 UNESCORTED KEYLESS ACCESS TO BE PROVIDED FOR UTILITY AC DISCONNECT, PV PRODUCTION METER, & BI-DIRECTIONAL METER. 5. PV EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690 AND POSTED WITH APPLICABLE WARNINGS, SIGNAGE, AND PLAQUES PER NEC 705-10, 690-17, & 690-64 (b)(5). 6. CIRCUITS: (1) CIRCUIT(S) OF 10 (20AMPS EACH) (1) CIRCUIT(S) OF 11 (20AMPS EACH) ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) ([Amps] (If Enphase. Based on 15 or 20A breakers)AMPS EACH) ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) ([Amps] (If Enphase. Based on 15 or 20A breakers)AMPS EACH) ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) ([Amps] (If Enphase. Based on 15 or 20A breakers)AMPS EACH) 1 2 3 4 5 6 CALL-OUTS: 1: SOLAR PANELS 2: INVERTERS 3: ENPHASE IQ COMBINER PANEL 4: UTILITY FUSED AC DISCONNECT 5: PV PRODUCTION METER 6: BI-DIRECTIONAL METER 7: MAIN ELECTRIC SERVICE DISTANCESSOLAR PANELS - INVERTERS: 5' MAX INVERTERS - IQ COMBINER PANEL: 50' MAX IQ COMBINER PANEL - UTILITY FUSED AC DISCONNECT: 2' UTILITY FUSED AC DISCONNECT - PV PRODUCTION METER: 2' PV PRODUCTION METER - BI-DIRECTIONAL METER: 2' BI-DIRECTIONAL METER - MAIN ELECTRIC SERVICE: 5' LABELS LOCATED ON PV PRODUCTION METER, BI- DIRECTIONAL METER, AC DISCONNECT(S), INVERTER(S), AND APPROPRIATE LABELS ON MAIN ELECTRIC SERVICE. ALL LABELS ARE PERMANENT, WEATHERPROOF, AND DURABLE THERE ARE NO CLEARANCE ISSUES DUE TO OVERHEAD POWERLINES. <10'HIBISCUS AVEARRAY 1 ARRAY 2 ARRAY 3 7 1 2 1 2 SETBACKS PER FIRE CODE 18" LG370N1K-A6 About LG Electronics USA, Inc. LG Electronics is a global leader in electronic products in the clean energy markets by offering solar PV panels and energy storage systems. The company first embarked on a solar energy source research program in 1985, supported by LG Group’s vast experience in the semi-conductor, LCD, chemistry and materials industries. In 2010, LG Solar successfully released its first MonoX® series to the market, which is now available in 32 countries. The NeON® (previous MonoX® NeON), NeON®2, NeON®2 BiFacial won the “Intersolar AWARD” in 2013, 2015 and 2016, which demonstrates LG’s leadership and innovation in the solar industry. 60 When you go solar, ask for the brand you can trust: LG Solar 370W Features Enhanced Performance Warranty LG NeON® 2 Black has an enhanced performance warranty. After 25 years, LG NeON® 2 Black is guaranteed at least 90.6% of initial performance. Roof Aesthetics LG NeON® 2 Black has been designed with aesthetics in mind using thinner wires that appear all black at a distance. Solid Performance on Hot Days LG NeON® 2 Black performs well on hot days due to its low temperature coefficient. 25-Year Limited Product Warranty The NeON® 2 Black is covered by a 25-year limited product warranty. In addition, up to $450 of labor costs will be covered in the rare case that a module needs to be repaired or replaced. yrs25 Warranty The LG NeON® 2 is LG’s best selling solar module and one of the most powerful and versatile modules on the market today. The cells are designed to appear all-black at a distance, and the performance warranty guarantees 90.6% of labeled power output at 25 years. I-V Curves General Data Cell Properties (Material/Type)Monocrystalline/N-type Cell Maker LG Cell Configuration 60 Cells (6 x 10) Number of Busbars 12EA Module Dimensions (L x W x H)1,740mm x 1,042mm x 40 mm Weight 18.6 kg Glass (Material)Tempered Glass with AR coating Backsheet (Color)Black Frame (Material)Anodized Aluminium Junction Box (Protection Degree)IP 68 with 3 Bypass Diodes Cables (Length)1,100mm x 2EA Connector (Type/Maker)MC 4/MC Electrical Properties (NMOT) Model LG370N1K-A6 Maximum Power (Pmax)[W]277 MPP Voltage (Vmpp)[V]33.3 MPP Current (Impp)[A]8.32 Open Circuit Voltage (Voc)[V]39.4 Short Circuit Current (Isc)[A]8.81 Temperature Characteristics NMOT*[°C] 42 ± 3 Pmax [%/°C]-0.35 Voc [%/°C]-0.26 Isc [%/°C] 0.03 *NMOT (Nominal Module Operating Temperature): Irradiance 800 W/m2, Ambient temperature 20°C, Wind speed 1 m/s, Spectrum AM 1.5 LG370N1K-A6 LG Electronics USA, Inc.Solar Business Division2000 Millbrook DriveLincolnshire, IL 60069 www.lg-solar.com Product specifications are subject to change without notice. LG370N1K-A6_AUS.pdf 020221 © 2021 LG Electronics USA, Inc. All rights reserved. 1042.0 / 41.0 (Size of Short Side)320.0 / 12.61002.0 / 39.4 (Distance between Grounding & Mounting Holes) 175.0 / 6.9 1100 / 43.3 Cable Length 40.0 / 1.57 105.0 / 4.1220.0 / 8.616 - 8.0 x 3.0 / 0.3 x 0.1 Drain Holes 8 - Ø4.3 / 0.2 Grounding Holes 8 - 8.5 x 12.0 / 0.3 x 0.5 Mounting Holes Junction Box 1100.0 / 43.3 (Distance between Mounting Holes)1300.0 / 51.2 (Distance between Mounting Holes)1740.0 / 68.5 (Size of Long Side)200W 400W 600W 800W 1000W Voltage [V]Current [A]12.0 10.0 8.0 6.0 4.0 2.0 0.0 0.0 10.05.0 20.015.0 30.025.0 45.040.035.0 Operating Conditions Operating Temperature [°C] -40 ~+85 Maximum System Voltage [V]1,000 (UL/IEC) Maximum Series Fuse Rating [A]20 Mechanical Test Load* (Front)[Pa/psf]5,400 Mechanical Test Load* (Rear)[Pa/psf]4,000 Mechanical Test Loads 6,000Pa/5,400Pa based on IEC 61215:2005 *Based on IEC 61215-2 : 2016 (Test Load = Design Load x Safety Factor (1.5)) Packaging Configuration Number of Modules per Pallet [EA]25 Number of Modules per 40' Container [EA]650 Number of Modules per 53’ Container [EA]850 Packaging Box Dimensions (L x W x H)[mm]1,790 x 1,120 x 1,213 Packaging Box Dimensions (L x W x H)[in]70.5 x 44.1 x 47.8 Packaging Box Gross Weight [kg]500 Packaging Box Gross Weight [lb]1,102 Dimensions (mm/inch) Certifications and Warranty Certifications* IEC 61215-1/-1-1/2 : 2016, IEC 61730-1/2 : 2016, UL 61730-1 : 2017, UL 61730-2 : 2017 ISO 9001, ISO 14001, ISO 50001 OHSAS 18001 Salt Mist Corrosion Test IEC 61701:2012 Severity 6 Ammonia Corrosion Test IEC 62716:2013 Module Fire Performance Type 2 (UL 61730) Fire Rating Class C (UL 790, ULC/ORD C 1703) Solar Module Product Warranty 25 Year Limited Solar Module Output Warranty Linear Warranty* *Improved: 1st year 98.5%, from 2-24th year: -0.33%/year down, 90.6% at year 25 *STC (Standard Test Condition): Irradiance 1000 W/m2, cell temperature 25°C, AM 1.5 Measurement Tolerence of Pmax: 3%+- Electrical Properties (STC*) Model LG370N1K-A6 Maximum Power (Pmax)[W]370 MPP Voltage (Vmpp)[V]35.5 MPP Current (Impp)[A]10.43 Open Circuit Voltage (Voc 5%)[V]41.9 Short Circuit Current (Isc 5%)[A]10.96 Module Efficiency [%]20.4 Power Tolerance [%]0 ~ +3 +- +- ® www.roof-tech.us info@roof-tech.us RT-MINI Self-flashing base for asphalt & metal roof-top PV mounting systems Dual bolt design: M8 or 5/16” for L-Foot & 1/4” for EMC 1/4” Hex Bolt upper channel Easy tapping screw guide M8 or 5/16” Hex Bolt bottom channel Flat lip for PV Cable clips RT-MINI is suitable for mounting any rail system with a conventional L-Foot. Call Now for more details 858-935-6064 ICC ESR 3575 RT-MINI Flexible Flashing certified by the International Code Council (ICC) Components RT2-00-MINIBK MINI base : 20 ea. Screw : 40 ea. Extra RT-Butyl : 10 ea. RT-Butyl is Roof Tech s flexible flashing used in 550,000 residential PV systems for the last 20 years. It is the first PV mounting system with Flexible Flashing certified by the ICC. ICC ESR-3575 ASTM2140 testing UV testing (7500 hrs.) www.roof-tech.us info@roof-tech.us 10620 Treena Street, Suite 230, San Diego, CA 92131 858.935.6064 Roof Tech Inc. Flexible Flashing 100% Waterproof Metal Flashing Retrofit Shedding water? Ra"er installa#on Deck installa#on ’ P.E. Stamped Letters available at www.roof-tech.us/support PAT : PENDING Dimensions in (mm) (D Y H (D Y H Engineered to ASTM D 1761 (Standard Test Methods for Mechanical Fasteners in Wood) DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, ULTRA RAIL COMP KIT SEE BELOW mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL, RUBBER 405 UP, 788 DOWN, 236 SIDE 2006 UP, 4000 DOWN, 1070 SIDE 12 LB-FT UL 2703, FILE E359313; WIND-DRIVEN RAIN TEST FROM UL SUBJECT 2582 0.80 PARTS LIST DESCRIPTIONPART NUMBERQTYITEM SNAPNRACK, UMBRELLA LAG, TYPE 3, 4IN, SS242-9226611 SNAPNRACK, ULTRA FOOT FOR U FLASHING, SILVER / BLACK242-01219, 242-0122012 SNAPNRACK, COMP FLASHING, 9IN X 12IN, SILVER / BLACK ALUM232-01375, 232-0137613 3 1 2 2 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, ULTRA RAIL COMP KIT SEE BELOW mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: ALL DIMENSIONS IN INCHES 11.75 3.25 8.75 .45 6.75 1.00 4.20 .30 3.25 1.00 1.00SLOT 1.50 2.781.78 1.50 .38 .30 1.37 1.62 UMBRELLA L FOOT PROPERTIES SKU DESCRIPTION 242-01219 ULTRA RAIL UMBRELLA L FOOT, SILVER 242-01220 ULTRA RAIL UMBRELLA L FOOT, BLACK COMP FLASHING PROPERTIES SKU DESCRIPTION 232-01375 COMP FLASHING, 9" X 12", BLACK ALUM 232-01376 COMP FLASHING, 9" X 12", SILVER ALUM .35 1.80 105° DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, UR-40 RAIL 232-02449, 232-02450, 232-02451 mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM N/A N/A N/A LB-FT UL 2703, FILE E359313 5.85 OPTIONS: CLEAR / BLACK ANODIZED MILL FINISH BUNDLES OF 144 BOXES OF 8 ALL DIMENSIONS IN INCHES UR-40 RAIL PROPERTIES SKU FINISH 232-02449 MILL 232-02450 CLEAR 232-02451 BLACK 1.624 1.500 CENTROID .750 .832 .792 EQUIVALENT PROPERTIES A0.357 in² Ixx 0.125 in⁴ Iyy 0.132 in⁴ Sx (TOP)0.150 in³ Sx (BOT)0.158 in³ Sy (LEFT)0.175 in³ Sy (RIGHT)0.175 in³