HomeMy WebLinkAboutLA199363-17809 Graphite Ln Permit PackRESIDENTIAL BUILDING
PERMIT APPLICATION
CITY OF LAKEVILLE
BUILDING INSPECTIONS DEPARTMENT
20195 HOLYOKE AVENUE
LAKEVILLE, MN 55044
952-985-4440
Office Use Only
__________________
Permit Number
___________________
Received By
___________________
Date Received
___________________
Fee Total
SITE ADDRESS:
MAILING ADDRESS: CITY: STATE: ZIP:
JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________
LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________
ESTIMATED VALUATION: PROPOSED START DATE: END DATE:
(New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION:
APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL
NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED)
PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License)
RESIDENT OWNER
NAME:_______________________________________________________________________________
HOME PHONE #:_____________________________ CELL PHONE:___________________________
GENERAL CONTRACTOR
Homeowner
Contractor
CONTRACTOR:_______________________________________________________________________
LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE)
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
PLUMBING WORK
Homeowner
Contractor
CONTRACTOR:__________________________________________LICENSE #: PM______________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
MECHANICAL WORK
Homeowner
Contractor
CONTRACTOR:________________________________________ _______________________________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
BOND #:_______________________________________ EXPIRATION DATE____________________
SEWER/WATER CONTRACTOR
New Construction Only
NAME:________________________________________________ ______________________________
HOME PHONE _____________________________ CELL PHONE:______________________________
BOND #:_______________________________________ EXPIRATION DATE____________________
INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE
ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY
APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND
ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND
WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START
WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN.
NAME OF APPLICANT (Please Print)DATE
APPLICANT’S SIGNATURE:
www.lakevillemn.gov
CONTRACTOR:________________________________________ _______________________________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
BOND #:_______________________________________ EXPIRATION DATE____________________
7 Metro Heating and Air
612-590-2678 612-590-2678
609 150th Ave NE Ham Lake Mn 55304
MB004178 12/3/22
RESIDENTIAL BUILDING PERMIT APPLICATION
PAGE 2
OFFICE USE ONLY
BUILDING PERMIT TYPE REQUIRED INSPECTIONS
SINGLE FAMILY DWELLING BUILDING
DUPLEX AS BUILT
TOWNHOUSE UNITS BUILDING FINAL
DETACHED TOWN HOUSE UNIT DECK FOOTING
CONDO FIREPLACE
ACESSORY BUILDING FOOTING
REROOF FOUNDATION
RESIDE FRAMING
PORCH FRAMING
GARAGES
INSULATION
RES ADDN/REPAIR/RMDL
DECK
PORCH
GARAGES LATH
LOWER LEVEL FINISH LOWER LEVEL FINAL
ADDITION OTHER
FOUNDATION ONLY PORCH FOOTING
MISCELLANEOUS POURED WALL
DEMO SEPTIC TANK REMOVAL
MOVED SITE
MECHANICAL
CITY BUILDING VALUATION: $AIR TEST
FINAL
BUILDING PERMIT FEES ROUGH-IN
$PERMIT FEE PLUMBING
$PLAN CHECK FINAL
$SURCHARGE ROUGH-IN
$METRO SAC METER SIZE
$CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE
$CITY SEWER HOOKUP UNIT SEWER/WATER
$LANDSCAPE ESCROW SEWER/WATER
$TREE ESCROW FINAL
$MISC ESCROW STREET DRAINTILE
$PLUMBING BUILDING INFORMATION
$MECHANICAL TYPE OF CONSTRUCTION
$SEWER WATER ZONING
$OTHER CODE EDITION
$TOTAL FIRE SUPPRESSION SYSTEM
OCCUPANCY GROUP
APPROVED BY:
BUILDING INSPECTOR: Date:
PLUMBING/MECHANICAL
INSPECTOR: Date:
COMMENTS:
20195 Holyoke Avenue, Lakeville, MN 55044
952-985-4400 952-985-4499 fax
www.lakevillemn.gov
Sewer & Water Tie Card
Address:________________________________________
Contractor:______________________________________
Permit Number:__________________________________
Final Date:________________
Street Drain-Tile:______
Size of Water Service: 1”
Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS
THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME
OF SEWER & WATER INSPECTION
1 8
SCALE: 1/4" = 1'-0"
FRONT ELEVATION
GENERAL NOTES:
1. ALL DOOR AND WINDOW HEADERS TO
BE S.P.F. #2 OR BETTER, SEE PLANS FOR
SIZES.
2. HOUSE TO BE BUILT PER CURRENT
I.R.C. CODES.
3. VERIFY GRADES AND ADJUST
FOUNDATION/FOOTING STEPS AS
NEEDED.
4. SEE PLANS FOR CEILING HEIGHTS
5. 4' HIGH POURED FDN. WALLS STD.
6. FLOOR PLAN DIMENSIONS ARE TO
FACE OF FRAMING AND FOUNDATION.
7. ALL TRADES & SUPPLIERS TO REVIEW
& VERIFY INFORMATION PERTINENT TO
THEIR WORK AND NOTIFY CONST. OF ANY
DISCREPANCIES PRIOR TO CONSTRUCTION.
8. NOTED CABINET SIZES ARE +/- AND
TO BE FIELD VERIFIED.
9. TRADES TO VERIFY BASE AND TRIM
SIZE PRIOR TO CONSTRUCTION.
10. ALL WALLS MORE THAN 10' H. TO BE
S.P.F. #2 OR BETTER.
11. EXTERIOR ELEVATIONS ARE CONCEPTUAL ONLY:
HOME SITE, FILL AND TOPOGRAPHY WILL DICTATE
ACTUAL GRADES AND MAY VARY FROM THOSE
SHOWN ON THE PLAN.
12. NOTE: SUBFLOOR JOINTS SHALL BE
STAGGERED FROM FLOOR TRUSS OR
JOIST JOINTS
OF
SHEET
MEH - 032PROJECT #
BUYER S/O
BUYER S/O
REVISIONS:
STARTED:
AGENT:X
XLOT 1, BLOCK 12, SUMMERS CREEK17809 GRAPHITE LN., LAKEVILLESONOMA 1600 PLANMARK ELLIOTT HOMES2-2-2022 REV. #1
SEE ROOF PLAN FOR
ROOF PITCHES AND
OVERHANGS
25'-6"CONC. PORCH
4" TRIM TYP.
6:12
T.O. 3048 SH
ALUM. SOFFIT
& FASCIA
30 YR. ARCH.
ASPHALT SHINGLES
2x OVER 6" TRIM
14" LP COLUMN, TYP.9'-1 1/8"T.O. SUBFLR.
T.O. PLATE 1'-8 1/4"T.O. FDN.9'-9 1/8"@ GARAGE
T.O. PLATE
12
12
12
12
STAT. (BLACKENED)1'-0"6" TRIM12" CANT.
10" TRIM METAL
CORNERS
TYP.
SADDLE
C/L
T.O. FDN.8'-11 1/2"@ DORMER
T.O. PLATE
8'-3 1/4"FP CHASE
24"x60" FALSE
6" TRIM& BATTEN
PER SPECS
10" TRIM
C/L
2x OVER 6" TRIM
GLS.GLS.GLS.GLS.
LP BOARD
STONE TOTAL: 79 SQ. FT. (29.3%)
TOTAL SQ. FT.: 269 SQ. FT.
MATERIAL CALCULATIONS: FRONT ELEV.
LP LAP SIDING TOTAL: 30 SQ. FT. (11.2%)
LP TRIM / PANEL/BB: 160 SQ. FT. (59.5%)
STONE TOTAL: 129 SQ. FT. (7.74%)
TOTAL SQ. FT.: 1,666.42
MATERIAL CALCULATIONS: ALL ELEV.
LP LAP SIDING TOTAL: 1070.06 SQ. FT. (64.21%)
LP TRIM / PANEL/BB: 467.36 SQ. FT. (28.05%)
LP PANEL 8" BOXED HEADER
6'-0"
Concept Approval
ONLY
Subject to Field Inspection
Inspector Date
2020
MN Bldg
Code
02/08/2022dmathews
EXTERIOR ELEVATIONS ARE CONCEPTUAL ONLY:
HOME SITE, FILL AND TOPOGRAPHY WILL DICTATE
ACTUAL GRADES AND MAY VARY FROM THOSE
SHOWN ON THE PLAN.2 8
MEH - 032PROJECT #
BUYER S/O
BUYER S/O
REVISIONS:
STARTED:
AGENT:X
XLOT 1, BLOCK 12, SUMMERS CREEK17809 GRAPHITE LN., LAKEVILLESONOMA 1600 PLANMARK ELLIOTT HOMES2-2-2022 REV. #1
OF
SHEET
SIDE ELEVATION
SIDE ELEVATION
SCALE: 1/8" = 1'-0"
SCALE: 1/8" = 1'-0"
REAR ELEVATION
SCALE: 1/8" = 1'-0"
12:12
ALUM. SOFFIT& FASCIA
12
6
12
6
12" CANT.
FP VENT
SEE ROOF PLAN
FOR PITCHES AND
OVERHANGS
LP SIDING PER SPECS
METAL CORNERS
4" LP TRIM @ WDWS. & DOORS TYP.
12:12
12:12 T.O. PLATE
9'-1 1/8"T.O. SUBFLR.
T.O. FDN.1'-8 1/4"TOTAL SQ. FT.: 588.00
MATERIAL CALCULATIONS: REAR ELEV.
LP LAP SIDING TOTAL: 380.85 SQ. FT. (64.77%)
LP TRIM / PANEL/BB: 157.15 SQ. FT. (26.73%)
& BATTENPER SPECS
LP BOARD
STONE TOTAL: 50 SQ. FT. (8.50%)
LP SIDING PER SPECS
@ GARAGE
9'-1 1/8"T.O. FDN.A/C UNIT
12:12
12
6
12
6
T.O. PLATE
SEE ROOF PLAN
FOR PITCHES AND
OVERHANGS
8" TRIM 8'-11 1/2"@ DORMERT.O. PLATE
12:12
ROOF LINEBEYOND
10" TRIM
T.O. PLATE
9'-1 1/8"T.O. SUBFLR.
T.O. FDN.1'-8 1/4"T.O. PLATE
METAL CORNERS
4" LP TRIM @ WDWS. & DOORS TYP.
TOTAL SQ. FT.: 529.00
MATERIAL CALCULATIONS: REAR ELEV.
LP LAP SIDING TOTAL: 476.32 SQ. FT. (90.04%)
LP TRIM / PANEL: 52.68 SQ. FT. (9.96%)
LP SIDING
PER SPECS
TOTAL SQ. FT.: 280.42
MATERIAL CALCULATIONS: REAR ELEV.
LP LAP SIDING TOTAL: 182.89 SQ. FT. (65.22%)
LP TRIM / PANEL/BB: 97.53 SQ. FT. (34.78%)
SEE ROOF PLAN
FOR PITCHES AND
OVERHANGS
ALUM. SOFFIT& FASCIA
6:12
LP SIDING
PER SPECS
12" CANT.
10" TRIM
METAL CORNERS
4" LP TRIM @ WDWS. & DOORS TYP.
T.O. PLATE
9'-1 1/8"T.O. SUBFLR.
T.O. FDN.1'-8 1/4"10" TRIM
SCALE: 3/16" = 1'-0"
FOUNDATION PLAN
3 8
MEH - 032PROJECT #
BUYER S/O
BUYER S/O
REVISIONS:
STARTED:
AGENT:X
XLOT 1, BLOCK 12, SUMMERS CREEK17809 GRAPHITE LN., LAKEVILLESONOMA 1600 PLANMARK ELLIOTT HOMES2-2-2022 REV. #1
OF
SHEET
A/C UNIT
w/ BRACKET
FURN
F.D.
WH
MECH. / STORAGE
WS FUT. 3068FUT. 2668FUT. BDRM. #3
FUT. FAMILY ROOM
R.I. BATH
FUT. 36" V.
CONC.
H.B.
H.B.
2" LEDGE TYP.
TO PROVIDE ADD'L.SUPPORT FOR
FILL FOR SLAB
TYP. FND @ HOUSE / GARAGE
W/ 4" LEDGE INSIDE
20X8 CONC. FTG.
2" FOAM
SUMP
H20
4" LEDGE2" FOAM
TYP. FND @ STOOP
10" POURED CONC.
W/ 4" LEDGE INSIDE
20X8 CONC. FTG.
UNEXCAVATED
2"
NOTE: NO DRYWALL @ CLG.
REQUIRED IN THIS AREA -
FIRE BLOCK @ PERIMETER
OF OPNG. (80 SQ. FT. MAX.)
6"2"
RADON VENT TO
TERMINATE IN
SUMP BASKET
SEE FIRST FLOOR FOR
GARAGE DOOR SIZE FOR M.O.
NOTE:
4" LEDGE
6"2"CONC.
CONC.
3 1/2'' CONC. FLOOR
TYP. FND @ HOUSE
20X8 FTG
REBAR PER CODE
TYP. FND @ BRG. WALL
2x4 STUDS 16" O.C.
16X8 FTG
REBAR PER CODE
4" CONC. CURB
KITCHEN ISLAND ABV.
FLR. TRUSS CO. FUT. 2468OPT.18" FLR. TRUSSES19.2" O.C. SPACING2-2x10 (DR)
5/0 BI-PASS
(9'-0"x11'-10")
(25'-6"x12'-6")
RADON VENT
FOUND. HELD IN 2"
FOR INSULATION
NOTE:
(TYP.)
NOTE: EXTERIOR HOUSE AND GARAGE/HOUSE
COMMON FDN. WALLS TO BE HELD 2'' IN.
DIMENSIONS SHOWN ARE TO FACE OF 2''
EXTERIOR RIGID INSULATION & FRAMING ABOVE
TO BE 5000 PSI CONC.NOTE: ALL FOOTINGS
2'' MIN.
2x8 TREATED
SILL-OVERHANG
FDN. 1 1/2''8"
2"
TYP. SIDE
WALL DETAIL
FOUND. HELD IN 2"
FOR INSULATION
NOTE:
(TYP.)
7'-4"4'-0"CONC. WDW WELL
R.O. 60" x 42"
2-9 1/2" LSL2"2"2"2"
8'-4" POURED FDN.
APPROX. 1,592 NET SQ. FT.
FILL FOR SLAB
UP 16 R (10" T.,
7-3/4" MAX. R.)
40'-0"
15'-0"12'-0"56'-0"6'-0"50'-0"56'-0"1'-0"28'-0"27'-0"14'-4"13'-8"9'-0 1/2"11'-6"5'-0"7'-6"14'-6"2'-6"40'-0"
19'-0"21'-0"
20'-0"
13'-0"6'-0"10'-0"10'-6"10'-6"18" FLR. TRUSSES19.2" O.C. SPACING3-9 1/2" LSL (DR)
FOUND. HELD IN 2"
FOR INSULATION
NOTE:
(TYP.) FUT. 206832x60FUT.TUB / SH3'-6"2x10 TRTD. JOISTS16" O.C. SPACING3-2x10 TRTD. (FL)
SMOKECM / 12" CANT. ABV.2x6 BRG.2x6 BRG.18" FLR. TRUSSES19.2" O.C. SPACING9'-4" H. FOUND. WALL
@ FRONT OF HOME
NOTE:
@ FRONT OF HOME
NOTE:
w/ TOP HUNG TRUSSES
w/ TOP HUNG TRUSSES
@ FRONT OF HOME
NOTE:
w/ TOP HUNG TRUSSES
11'-1 1/2"3'-2 1/2"9'-9 3/4"15'-10 1/4"
11'-8 3/4"3'-2"1'-3"3'-0"7'-10"13'-0 1/4"3'-9"3'-10"7'-1 1/2"21'-3"11'-6"17'-3"9'-1 1/2"10'-4"
30"x30" CONC.PAD FTG.
6x6 COL.
7'-2"
16" DIA. FROSTFOOTING (60" D.)
6x6 TRTD. COL.
2-2x10 (DR)
2-2x10 (FL)
(2) TR
3-9 1/2" LSL (DR)5'-5"2'-11"2'-9"2'-4"
EGRESS WELL
w/ LADDER
6042 GLIDER
29'-2"
6"
4"
10"
GARAGE/HOUSE
COMMON WALL
2x8 TREATED SILL
OVERHANG FDN. 2''
GARAGE SLAB
2'' RIGID INSUL.
MAIN FLR
8" POURED CONC. (8'-4" H.)
& HOUSE/PORCH
9'-4" H. FOUND. WALL
9'-4" H. FOUND. WALL
10" POURED CONC.
BWP above
BWP above
SCALE: 3/16" = 1'-0"
MAIN FLOOR PLAN
4 8
MEH - 032PROJECT #
BUYER S/O
BUYER S/O
REVISIONS:
STARTED:
AGENT:X
XLOT 1, BLOCK 12, SUMMERS CREEK17809 GRAPHITE LN., LAKEVILLESONOMA 1600 PLANMARK ELLIOTT HOMES2-2-2022 REV. #1
OF
SHEETP.H.TBTR
DW
GAS RANGEMICRO ABV.
FLUSH OH.
LNDRY.
DRYERWASHER
9' CLG. / LVP
WIRE SH.
(OPT. UPPERS)
(VENT TO OUTSIDE)
NOTE:
- STD. BASE & CASING TO BE PRINCETON
- 1/2 WALL w/ WD. CAP & INVERTED CASING
NOTE:
2X6 EXT. WALLS U.N.O.
2X4 INT. WALLS U.N.O.
- 42" UPPER CABINETS
DOOR ROUGH OPENINGS:
83" HEIGHT
82" OVER VINYL
CERAMIC TILE & WOOD
82" OVER CARPET
SRO = SHEET ROCKED OPNG
BIFOLD DOORS:
PREHUNG UNITS:
2" WIDER THAN DOOR
(EXAMPLE: 2668 )
1 3/8" WIDER THAN DOOR
FINISH SIZE NOTED ON PLAN
CO = CASED OPENING ( WOOD )
(EXAMPLE: 2668 )
FINISH SIZE NOTED ON PLAN
RO. 1 1/2" WIDER, 83" HIGH
R.O. 1" WIDER, 83" HIGH
PER SPECS
DRIVEWAY
NOTE:
REF.
KITCHEN
9' CLG. / LVP12'-3" x 12'-6"
(155 SQ. FT.)BUILT-INS3-14" LVL
GREAT ROOM
9' CLG. / LVP FLR.42" GAS F.P.12'-8" x 13'-0" (167 SQ. FT.)
/ LVP
42" W. CONC. SIDEWALK OPT.FIBRGLS.
60x36 SHWR.
UNIT
5'-0"210682-9 1/2" LSL2x6 FOYER
9' CLG. / LVP
6'-11" x 7'-1"
(51 SQ. FT.)
PORCH
CONCRETE
O. BATH
9' CLG. / VIN.
2x6 WALLS U.N.O.
4" SLOPED CONC.
GARAGE CEIL. TO BE 5/8" TYPE 'X'
GYP. BD. WALLS TO BE 1/2" GYP.SHEATHING. ALL WALLS & CEILINGS TO
HAVE ONE COAT FIRETAPE
GARAGE
SLOPE CONC.6'x8' PATIO DR.
16'x7' O.H.D.
R.O. 16'-1" FRAMING
O. CLST
8' CLG. /
CARPET36" VAN. BATH 2
BEDROOM #2
2
6
6
8 3648 SH @ 8'9' CLG. / CARPET
9' CLG. / VIN.
1/2 WALL w/ WD. CAP MANUF. TRUSSES24 O.C.OPT. BUFFET CABS.(12'-0"x12'-0")
EXTERIOR FLOOR PLAN DIMENSIONS
ARE TO OUTSIDE OF SHEATHING, INTERIOR
DIMENSIONS ARE TO FRAMING.
NOTE:
ALL DRS/ WIN.'S REQUIRE
4" ON SIDES FOR CASING
NOTE:
2X6 EXT. WALLS U.N.O.
2X4 INT. WALLS U.N.O.
HEADER SPANS:
UP TO 4'-11'' = 1 TRIMMER
5'-0'' AND BIGGER = 2 TRIMMERS
UNLESS NOTED OTHERWISE
INDICATES LOCATION OF SOLID BRG.32x60FGLS.TUB / SH (134 SQ. FT.)
OWNERS BDRM.
9' CLG. / CARPET
(12'-6"x13'-0")
(164 SQ. FT.)
SMOKE
CM /
SD
2 - 4072 SH @ 8'
DN 16 R (10" T.,
7-3/4" MAX. R.)
2x6
8/0 H. SOFFIT
MANUF. TRUSSES
24 O.C.
14" LP COL.* BEADBD. CLG.ATTICACCESSAPPROX. 512 SQ. FT.
MUDRM.
9' CLG. / LVP
BENCH /
APPROX. 9'-0'' CLG. @ MAIN LEVEL
APPROX. 1,592 SQ. FT.
HOOKS3068 MTL.3080 MTL.R&SH2 - 20682668R&SH24682
6
6
8 2068
R&SH
R&SHLINENSH.
9' CLG. / CARPET
9' CLG. 8' SOFFIT28688' SOFFIT
(5) SH.
(5) SH.
9' CLG. / LVP 2668R&SHR&SH36" VAN. LIN.CAB. 30683068 PKT.FLDG. C'TOP.(OPEN UNDER)2 - 4072 SH @ 8'60" VAN. DINING
9' CLG. / LVP FLR.10'-0" x 9'-0" (90 SQ. FT.)
3672 SH @ 8'3672 SH @ 8'4872 PICT. @ 8'
12'x10' DECK
DECKING PER SPECS
MANUF. TRUSSES24 O.C.40'-0"
15'-0"12'-0"
8'-10"11'-6"12'-11"6'-9"56'-0"6'-0"50'-0"12'-8"5'-0 1/2"5'-5 1/2"12'-8 3/4"7"3'-11"5'-2 1/2"4'-4 3/4"6'-2 1/4"6'-6 1/2"56'-0"1'-0"28'-0"27'-0"14'-4"13'-8"3'-2"9'-0 1/2"11'-6"5'-0"7'-6"14'-6"2'-6"40'-0"
19'-0"21'-0"
20'-0"
13'-0"6'-0"
6'-6"6'-6"10'-0"10'-6"10'-6"
RADON VENT
2x6 PA
4"7'-0"4"12'-4"2-7 1/4" LSL (DR)2-2x8 (DR)4"LP SOFFIT
SD
SMOKECM /
OPT. VAULT
BUILT-INSOPT.OPT. 2-2668 PKT.2'-4 1/4"1'-10 1/2"2424 PICT. @ 8'2424 PICT. @ 8'2'-0 1/2"2'-0 1/2"or 3068 BARN DR.OPT. EXP.ISLAND
INDICATED
STONE WHERE2448 SH @ 8'5'-0"WD. STEP
2'-9"
4'-4"3'-9"2'-9"5'-4 3/4"6'-1 1/4"
6'-1 1/4"
4'-8 3/4"12'-11 1/4"
7'-0 3/4"
2'-0"
1'-4"
7'-10"15'-0 1/2"
2'-7 1/2"2'-4"6'-2 3/4"3'-6"3'-0 1/2"3'-11 1/2"2'-8 3/4"2'-0"4'-0"5'-0"12"
CANT.9'-4"5'-2"2'-6"36" H. WALL w/ WD. CAP
1'-3"2 1/2"
3'-0"7"6'-8"7'-8"4'-0"9'-8"3'-9"3'-10"3'-5"3'-5"3'-0"3'-0"3'-0"2-2x102-2x102-2x102-2x104 1/2"4 1/2"
8'-10 1/2"MANUF. TRUSSES24 O.C.FP CHASEFALSE
2-9 1/2" LSL (CONT.)2-9 1/2" LSL
2-2x10
(2) TR
(2) TR
2-2x10
2-9 1/2" LSL
P.H.
TR
TB
4x4 TRTD. COL.
3068 PKT.
3'-5"
RECESSED STEP
1-COURSE DROP
MICRO/ OVEN
OPT. UPGRADED KITCHEN
DW
GAS COOKTOPHOOD VENT ABV.(VENT TO OUTSIDE)
REF.
KITCHEN
OPT. EXP.ISLAND
4
4
4
4
4
4
4 4
PFH PFH
8
4
Temper
8
5 8
MEH - 032PROJECT #
BUYER S/O
BUYER S/O
REVISIONS:
STARTED:
AGENT:X
XLOT 1, BLOCK 12, SUMMERS CREEK17809 GRAPHITE LN., LAKEVILLESONOMA 1600 PLANMARK ELLIOTT HOMES2-2-2022 REV. #1
OF
SHEET
SCALE: 1/4" = 1'-0"
SECTION1
5
N.T.S.
HOUSE / DECK CONNECTION DETAIL4
5
R-5 THERMAX AT
INTERIOR FOUND.
AS REQUIRED
3/4" T & G FLOOR
NOTE: SUBFLOOR JOINTS SHALL BESTAGGERED FROM FLOOR TRUSS ORJOIST JOINTS
R=0.61
R=49.00
R=50.25
R=0.58
R=.061
TOTAL
TRUSSES - 24" OC
BLOWN INSULATION
INTERIOR AIR FILM
VAPOR BARRIER
15/32" OSB SHTG.
15# FELT
EXTERIOR AIR FILM
ICE AND SNOW SHIELD
30 YR. ARCH. ASPHALT SHINGLES
5/8" GYP BD
ALUM. SOFFIT & FASCIA
1/2" GYP BD
INTERIOR AIR FILM
TOTAL
SIDING PER SPECS
2x6 STUDS 16" OC
R=1.06
R=
R=
R=21.00
R=0.45
R=0.17
R=23.36
VAPOR BARRIER
FULL WALL BATT INSUL.
EXTERIOR AIR FILM
R=0.68
7/16" OSB SHTG.
8" AGGREGATE6 MIL POLY. LAP SEAMS 12"10"HEEL HT.1/2" GYP. SHEATHING ON GARAGE WALLS
5/8" TYPE 'X' GYP. BD. ON GARAGE CEILS.
18" FLOOR TRUSSES1'-8 1/4"9'-1 1/8"T.O. FDN.
T.O. SUBFLR.
T.O. PLATE
TRUSSES @ 24" O.C.
(DESIGNED BY MFR)
6
12
R-49 INSUL.9'-4"GARAGE
4" SLOPED CONC.
W/ REBAR PER
ENGINEERS REPORT
9'-4" POURED WALL
DRAIN TILE
10" POURED WALL
R-5 INSUL. ATINTERIOR FOUND.9'-9 1/8"O. BATH
OWNERS BDRM.
20x8 CONC. FTG.16x8 CONC. FTG.
16x8 CONC. FTG.
SPRAY FOAM RIM
8'-2" +/-FOUND. HELD IN 2"
FOR INSULATION TYP.
NOTE:
(INSUL. FLUSH w/ SHTG.)
CANT. 2x8 SILL PLT. 1-1/2"3 1/2" CONC. FLOOR
2" RIGID INSULATION
R-10 w/ WATCHDOG
WATERPROOF COATING
AROUND HOUSE FOUND.
20x8 CONC. FTG.8 1/4"6"HEEL HT.6
12
FUT. BDRM. #3 R.I. BATH 8 1/4"NOTE: TOP HUNG TRUSSES
AT FRONT OF HOME
(9'-4" H. FDN. WALL)
SPRAY FOAM RIM
4"12"6 3/4" +/-4'-0"
JOIST
W/ 2-3/8" LAG BOLTS
ICE & WATER EXTENDS
5" UP SHEATING UNDER
INSTALL TOP OF LEDGER3 5/8" BELOW TOP OF
3/4" SUBFLOOR (THIS
ALLOWS 5/4 X 4 THRESHOLD
AT DOOR)
HANGER
TREATED 2X10 LEDGER
RUN HOUSE WRAP BEHIND
LEDGER (LEAVE 6" TAIL@ TOP, BOTTOM, & SIDES)
HOUSEWRAP
@ 24" O.C. -OR-
EMBED 2" MIN.
8 INCHES O.C. MAX OR EQUAL,
W/ "LEDERLOK" FASTENERS
CONT. 2X4 RIBBON
SPRAY FOAM INSUL. R-21 MIN.
RIM BOARD
TREATED
JOIST
JOIST
RIM
BD.
SKIRT
1"
HOUSE
END OF DECK
HOUSE LATERAL LOAD
SIMPSON DTT1Z DECK-TO
CONNECTOR - (4) PER DECK
OR 8-10DX1 1/2" NAILS
6-SD#9X1 1/2" SCREWS
HDG WASHER OR SDWH
3/8" HDG LAG SCREW WITH
TIMBER-HEX HDG SCREW
(SHOWN) INTO TOP PLATE,
STUDS, OR HEADER
CONT. 2X8 RIBBON
DRAIN TILE
3/4" WASHED ROCK
CONTINUOUS
UNDER SLAB0'-16"
SILT FABRIC
FOUNDATION WALL
CONC. FTG.
4" DRAIN TILE
2
SCALE: NO SCALE5 TOP OF FDN.RIM DETAIL3
SCALE: NO SCALE5
2" RIGID INSULATION
R-10 w/ WATCHDOG
WATERPROOF COATING
AROUND HOUSE FOUND.
2" RIGID INSULATION
R-10 w/ WATCHDOG
WATERPROOF COATING
AROUND HOUSE FOUND.
2x8 TRTD. SILL
SHEATHING FLUSH
WITH INSULATION
NOTE:
FOUNDATION TO BE
HELD IN 2" FROM
SHEATHING & OUTSIDE
DIMENSIONS.
CANTED 1-1/2"
6 8
MEH - 032PROJECT #
BUYER S/O
BUYER S/O
REVISIONS:
STARTED:
AGENT:X
XLOT 1, BLOCK 12, SUMMERS CREEK17809 GRAPHITE LN., LAKEVILLESONOMA 1600 PLANMARK ELLIOTT HOMES2-2-2022 REV. #1
OF
SHEET
SCALE: 1/4" = 1'-0"
SECTION1
6
N.T.S.
PORTAL FRAME DETAIL2
6 N.T.S.
RADON DETAIL3
6
SIMPSON STRONG
TIE Ab46z
HEADER
HURRICANE
CLIP ATTACHEDTO COLUMN
& BEAM
11 7/8" OSB STRINGER
W/ 2X4 BRACING
10 1/2" BULLNOSE LSL TREAD
1X8 PINE S4S RISER
NOTE:
MAX RISE= 7 3/4"
MIN. RUN= 10"
6'-8" CLEAR HEADROOM
BATH 2 BEDROOM #2GREAT RM.
3/4" T & G FLOOR
NOTE: SUBFLOOR JOINTS SHALL BESTAGGERED FROM FLOOR TRUSS ORJOIST JOINTS
8" AGGREGATE
6 MIL POLY. LAP SEAMS 12"
18" FLOOR TRUSSES9'-1 1/8"T.O. SUBFLR.
T.O. PLATE
TRUSSES @ 24" O.C.
(DESIGNED BY MFR)
R-49 INSUL.9'-4"W/ REBAR PER
ENGINEERS REPORT
9'-4" POURED WALL
DRAIN TILE
10" POURED WALL
R-5 INSUL. AT
INTERIOR FOUND.
20x8 CONC. FTG.16x8 CONC. FTG.
SPRAY FOAM RIM
8'-2" +/-FOUND. HELD IN 2"
FOR INSULATION TYP.
NOTE:
(INSUL. FLUSH w/ SHTG.)
CANT. 2x8 SILL PLT. 1-1/2"
3 1/2" CONC. FLOOR
2" RIGID INSULATION
R-10 w/ WATCHDOG
WATERPROOF COATING
AROUND HOUSE FOUND.
PORCH
14" SQ.
LP COLUMN
20x8 CONC. FTG.
MECH. / STORAGEFUT. FAMILY ROOM
KITCHEN
8 1/4"4x4 TRTD. COL.
LP TRIM
2
5
3
5
ALUM. SOFFIT & FASCIA 10"HEEL HT.6
12
6
12
3.25
12
4 1/4"R-5 THERMAX AT
INTERIOR FOUND.
AS REQUIRED
4" LEDGE
NOTE: TOP HUNG TRUSSES
AT FRONT OF HOME
(9'-4" H. FDN. WALL)
CONC. STOOP6 3/4" +/-4"SPRAY FOAM RIM
16R4'-0"
6'-0"9'-1"1'-8 1/4"T.O. FDN.
SIMPSON STHD14 HOLD DOWN
SIMPSON LSTA36 STRAP ON INSIDE FACE OF WALL
5/8" ANCHOR BOLT
1/2" OSB SHEATHING
HEADER- SEE PLAN FOR SIZE
FASTEN SHEATHING TO HEADER WITH 8d COMMON OR
GALVANIZED BOX NAILS IN 3" GRID PATTERN AS
SHOWN, AND 3" O.C. IN ALL FRAMING MEMBERS TYP.
SHEATHING SPLICE (IF NEEDED) MUST BELOCATED WITH-IN 24" OF THE MID HEIGHTOF THE DOOR OPENING. PROVIDE 2-2X6BLOCKING BEHIND SPLICE
FASTEN TOP PLATE TO HEADER WITH
2 ROWS OF 16d SINKER NAILS 3" O.C.
BLOCK BACK SIDE OF HEADER FLUSH WITH STUDSAT STRAP LOCATIONS
UNEXCAVATED SOIL
ALL SLABS WILL HAVE A MIN. 4" CLEAN AGGREGATE, COVERED BY
6 MIL POLY. THIS POLY WILL HAVE 12" LAP AT ALL SEAMS. ALL TEARS OR
PUNCTURES WILL BE SEALED OR COVERED BY POLY. ALL OPENINGS WILL BE
SEALED USING POLYURETHANE CAULK OR ELASTOMERIC SEALANT AT ALL OPNGS.
AN INSTALLED 3" GASTIGHT PVC PIPE WILL BE CONNECTED TO THE DRAIN
TILE SYSTEM. A "T" FITTING WILL BE INSTALLED WITH 10 L.F. EACH END
OF THE "T", OF PERFORATED PIPE, INTO THE DRAIN TILE SYSTEM. THE SHORTEST
ROUTE WILL BE USED TO EXIT THE ROOF SYSTEM, WITH A MAX. OF 2 90
DEGREE ELBOWS. IN UNCONDITIONED AREAS, THE RADON EXHAUST PIPE WILL
BE INSULATED WITH AN R4 SLEEVE. THIS PIPE WILL BE LABELED "PASSIVE
RADON" AT ALL ACCESSIBLE LOCATIONS.
AT ROOF EXIT LOCATIONS, MAINTAIN A 10' DISTANCE TO ANY WINDOW
LOCATION, 2' BELOW EXHAUST POINT AND ANY ADJACENT STRUCTURE. THE
LOCATION OF THE EXIT POINT, IN TRUSS AREA, WILL BE CLEAR OF ANY
OBSTRUCTIONS WITHIN 24" HORIZONTALLY AND 36" VERTICALLY.
INSTALL AN OUTLET AND PULL CHORD LIGHT FOR FUTURE EXHAUST FAN
ADDITION.
7 8
MEH - 032PROJECT #
BUYER S/O
BUYER S/O
REVISIONS:
STARTED:
AGENT:X
XLOT 1, BLOCK 12, SUMMERS CREEK17809 GRAPHITE LN., LAKEVILLESONOMA 1600 PLANMARK ELLIOTT HOMES2-2-2022 REV. #1
OF
SHEET
SCALE: 3/16" = 1'-0"
ROOF PLAN1
7 SADDLENOTE:
SEE ROOF TRUSS LAYOUT
FOR TRUSS DIRECTION
AND GIRDER LOCATIONS
PROVIDED BY MANUFACTURER
PROVIDE ATTIC VENTILATION EQUAL TO 1/150th
ATTIC AREA. IF 50% OR MORE IS PROVIDED IN
UPPER PORTION OF THE ROOF AND REMAINDER
IS PROVIDED IN SOFFIT VENTS, IT MAY BE
REDUCED TO 1/300th ATTIC AREA.
ICE AND WATER SHIELD
6'-0" IN FROM EAVES
1'-6" ON EACH SIDE OF VALLEY
WHERE WALLS MEET ROOF
ICE & WATER SHIELD SHOULD
RUN UP WALL 1'-6" AND OUT
FROM WALL 1'-6"
NOTE:
NOTE:
NOTE:
1'-6"1'-6"12:12 RIDGERIDGE
1'-6"1'-6"1'-6"6:126:1212:1212:12 12:12RIDGE RIDGE12:12 12:12
SCALE: 1/4" = 1'-0"
MAIN FLR. ELECTRICAL PLAN
8 8
MEH - 032PROJECT #
BUYER S/O
BUYER S/O
REVISIONS:
STARTED:
AGENT:X
XLOT 1, BLOCK 12, SUMMERS CREEK17809 GRAPHITE LN., LAKEVILLESONOMA 1600 PLANMARK ELLIOTT HOMES2-2-2022 REV. #1
OF
SHEET
SCALE: 1/4" = 1'-0"
LOWER LEVEL ELECTRICAL PLAN
TVABV. FP.NOTE:
TECH TUBE
TV W.P.G.F.I.P.S3S3LTS.
PENDANT
3 SS
C/L
7'-6"3'-2"5'-3 1/2"TV
DW
GAS RANGEMICRO ABV.
LNDRY.
DRYERWASHER
(VENT TO OUTSIDE)
REF.
KITCHEN
GREAT ROOM
FOYER
O. BATH
GARAGE
O. CLST
BATH 2
BEDROOM #2
OWNERS BDRM.
SMOKE
CM /
SD
ATTICACCESSMUDRM.
DINING
12'x10' DECK
SD
SMOKECM /
GDO
G.F.I.P.
S
G.F.I.P.G.F.I.P.G.F.I.P.W.P.
S
SS
S
S
SS
3 S3S3S4G.F.I.P.S3S3SS3
S3
S3
S3
SS3 SSS3DISP
S
SS3
S
TO LIGHT
S
G.F.I.P.G.F.I.P.
SS
RGH.-IN FAN
OPT.
PORCH
RGH.-IN FAN
OPT.
S
DUPLEX CONVENIENCE OUTLET
DUPLEX OUTLET ABOVE COUNTER
WEATHERPROOF DUPLEX OUTLET
HALF-SWITCHED DUPLEX OUTLET
DUPLEX OUTLET IN FLOOR
220 VOLT OUTLET
WALL SWITCH
THREE-WAY SWITCH
FOUR-WAY SWITCH
CEILING MOUNTED INCANDESCENT LIGHT FIXTURE
WALL MOUNTED INCANDESCENT LIGHT FIXTURE
RECESSED INCANDESCENT LIGHT FIXTURE
LIGHT FIXTURE WITH PULL CHAIN
TRACK LIGHT
FLOURESCENT LIGHT FIXTURE
EXHAUST FAN
EXHAUST FAN/LIGHT COMBINATION
CHIMES (OPTIONAL)
SMOKE DETECTOR
TELEPHONE (OPTIONAL)
TELEVISION (OPTIONAL)
THERMOSTAT
ELECTRIC METER
ELECTRIC PANEL
SPEAKER (OPTIONAL)
TV
T
M
CH
SD
P.C.
S
S
S
4
3
W.P.
ELECTRICAL KEY
DUPLEX OUTLET (GROUND FAULT PROTECTED)G.F.I.P.
RECESSED INCANDESCENT EYE BALL FIXTURE
CARBON MONOXIDE DETECTORCM
GARAGE DOOR
OPENER OUTLETGDO
FLUORESCENT
LIGHT PER SPEC
FAN/LIGHT COMBO
PREWIRE, PROVIDE
ADEQUATE
SUPPORT
4 BULB FIXTURE
3 BULB FIXTURE
200 AMP SERVICE
LIGHTING PACKAGE: T.B.D.
LINE TO DRYER: T.B.D.G.F.I.P.EXCH.AIRFURN
F.D.
WH
MECH. / STORAGE
WS
FUT. BDRM. #5 FUT. FAMILY ROOM
R.I. BATH
SUMPH20
OPT.
RADON VENT
SMOKECM /
S
S3S
TO LIGHT
A/C UNITw/ BRACKET G.F.I.P.G.F.I.P.
BW
MEH - 032PROJECT #
BUYER S/O
BUYER S/O
REVISIONS:
STARTED:
AGENT:X
XLOT 1, BLOCK 12, SUMMERS CREEK17809 GRAPHITE LN., LAKEVILLESONOMA 1600 PLANMARK ELLIOTT HOMES2-2-2022 REV. #1
SHEET
N.T.S.
MAIN LEVEL BRACEWALL1
BW
N.T.S.
BRACEWALL DETAILS2
BW
GARAGE PORTAL FRAMING PER BUILDING CODE IRC R602.10.6.4
BRACED WALL METHOD CS-WSPBRACED WALLLINE 1BRACED WALLLINE ABRACED WALLLINE 2BRACED WALLLINE B
BRACED WALL
LINE C4'-0" PANEL4'-0" PANEL8'-0" GYP. PANEL
2'-11" PANEL
LNDRY.
DRYERWASHER
KITCHEN
GREAT ROOM
FOYER
O. BATH
GARAGE
O. CLST
BATH 2
BEDROOM #2
OWNERS BDRM.ATTICACCESSMUDRM.
DINING
12'x10' DECK
3'-6" PANEL3'-1" PANEL6'-7" PANEL3'-5" PANEL
4'-0" PANEL4'-0" PANEL4'-0" PANEL4'-0" PANEL4'-0" PANEL5'-7" GYP. PANEL4'-2" GYP. PANEL
3'-2" GYP. PANEL
3'-6" PANEL
2'-3" PANEL 2'-3" PANEL
7'-6" PANELMIN. 3''x11 1/4'' NET HEADER(STEEL HDR. PROHIBITED)
EXTENT OF HEADER W/ SINGLE PORTAL FRAME
ONE BRACED WALL PANEL
10'-0'' MAX. HEIGHT(TOP OF HDR.)TOP OF FDN.TOP OF CONC FLOOR AT OPENING
MIN. 2-2x4 FRAMING
STUD POST
CONTINUOUS HEADER WITH DOUBLE PORTAL FRAMES
TWO BRACED WALL PANELS
6' TO 18' OPENING
FASTEN TOP PLATE TO HEADER W/ 2ROWS OF 16d SINKER NAILS @ 3'' O.C. TYP.
1000 LB. STRAP OPPOSITE SIDE OF SHEATHING
FASTEN SHEATHING TO HEADER W/ 8dCOMMON OR GALV. BOX NAILS IN 3'' GRIDPATTERN SHOWN AND 3'' O.C. IN ALLFRAMING(STUDS, BLOCK'G AND SILLS)TYP.
MIN. WIDTH PER TABLE R602.10.5
3/8'' MIN. WOOD STRUCTURAL PANEL SHEATH'G.
MIN. 2-2x4
MIN. 4200 LB. TIE DOWN DEVICE(EMBED INTOFOUNDATION AND NAILED INTO FRAMING
MIN. (2) 1/2'' DIA. ANCHOR BOLT INSTALLED PER R403.1.6
W
SEE LEFT FOR
TYP. PORTAL
FRAME CONST.
FOR A PANEL SPLICE
(IF NEEDED) PANELEDGES SHALL BEBLOCKED AND OCCURWITHIN 24'' OF MID-HEIGHT. ONE ROW OFTYP. SHEATH'G. TOFRAMING NAILING ISREQUIRED.IF 2x4 BLOCK'G. IS USEDTHE 2x4'S MUST BE NAILEDTOGETHER W/ 3 16dSINKER NAILS
W/ 2''x2''x3/16'' PLATE WASHER12'-0'' MAX. HEIGHT(TOP OF WALL)FULL HEIGHT OF WALL - SEE TO RIGHT FOR SPLICESPONY WALL HT.EXTENT OF HEADER
TENSION STRAP PER
TABLE R602.10.6.4 (ON
OPPOSITE SIDE OF
SHEATHING
ANCHOR BOLTSPER SECTION
R403.1.6
BRACED WALL LINE
CONTINUOUSLYSHEATHED WITHWOOD STRUCTURALPANELS
TOP OF FLOOR AT OPENING
FLOOR FRAMING ASSEMBLY PER PLAN W/ WOOD STRUCTURAL PANEL SHEATHING
TOP OF FLOOR AT OPENING
FLOOR FRAMING ASSEMBLY PER PLAN
WOOD STRUCTURAL PANEL SHEATHING
TO TOP OF BAND OR RIM JOIST
NAIL SOLE PLATE TO FLR
FRAMING PER
TABLE R602.3(1)
(2) FRAMING ANCHORS APPLIED ACROSS
SHEATHING JOINT WITH A CAPACITY OF
670# IN HORIZ. AND VERT. DIRECTIONS
SEE LEFT FORTYP. PORTALFRAME CONST.
ON CONCRETE FOUNDATION
ON RAISED WOOD FLOOR - FRAMING ANCHOR OPTION
TOP OF FLOOR AT OPENING
FLOOR FRAMING ASSEMBLY PER PLAN W/ WOOD STRUCTURAL PANEL SHEATHING
TOP OF FLOOR AT OPENING
FLOOR FRAMING ASSEMBLY PER PLAN
WOOD STRUCTURAL PANEL SHEATHING
TO TOP OF BAND OR RIM JOIST
NAIL SOLE
PLATE TO FLR
FRAMING PER
TABLE R602.3(1)
SEE LEFT FOR
TYP. PORTAL
FRAME CONST.
ON RAISED WOOD FLOOR - OVERLAP FLOOR OPTION
MIN. OVERLAP 9 1/4''WOOD STRUCTURAL PANEL SHEATHINGCONTINUOUS OVER BAND OR RIM JOIST
MIN. OVERLAP 9 1/4''ATTACH TO RIM/BAND JOIST W/ 8dCOMMON NAILS AT 3'' O.C. AS SHOWN
DBL TOP PLATE
BOTTOM PLATE
STUDS AT 16'' O.C.
W/ 6d NAILS @ 6'' O.C.
4'-0"8'-0'' MIN., SEE PLANINTERMEDIATE
6''3"W/ 6d NAILS @ 3'' O.C.
EDGES NAILED
Date Certificate Posted
X Passive (No Fan )Active (With fan and monometer
or other system monitoring
device)
Location (or future location) of Fan:
Other Please Describe Here
R-15
R-20 X
R-21 X
R-49 X
N/A
R-30 X
N/A
X Not applicable, all ducts located in conditioned space
X Not required per mech. code
Passive
Powered
Interlocked with exhaust device.
Describe:
Input in
BTUS:
60,000 Capacity in
Gallons:
Other, describe:
AFUE or
HSPF%
92
Cfm's
X " round duct OR
" metal duct
X Not required per mech. code
Passive
Low: Other, describe:
X Low:
Location of fan(s), describe: Cfm's
6" " Flex duct OR
" metal duct Total ventilation (intermittent + continuous) rate in cfms:
Balanced Ventilation capacity in cfms:
High:
High:
MECHANICAL VENTILATION SYSTEM
Capacity continuous ventilation rate in cfms:
46,750
Heating Gain Cooling Load
13 SEER R4 10
Model
Heating System
50
41 82
Select Type
0.7
Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air
source heat pump with gas back-up furnace):
17,800Residential Load Calculation
SEER
/EER
NAT Gas
Bryant
91250036060
Heating Loss
Manufacturer Bryant
NAT Gas
Output in
Tons:
PROG50 113ANA024
Location of duct or system:
Heating or Cooling Ducts Outside Conditioned Spaces
Electric
Make-up Air Select a Type
Rheem
Domestic Water
Heater
MECHANICAL SYSTEMS
Rating or Size
Efficiency
2
Insulation Location
Foam, Closed Cell0.28
Describe other insulated areas
Interior WallsNon or Not ApplicableFiberglass, BlownFiberglass, Batts Foundation Wall
R-value
Average U-Factor (excludes skylights and one door ) U:
Duct system air tightness: Building envelope air tightness:
Attic
Rim Joist (1st Floor)
Mechanical Room
Heat Recover Ventilator (HRV) Capacity in cfms:
Energy Recover Ventilator (ERV) Capacity in cfms:
Ceiling, flat
Attic
Fuel Type
Solar Heat Gain Coefficient (SHGC):
Windows & Doors
Ceiling, vaulted
Bay Windows or cantilevered areas
Floors over unconditioned area
Rim Joist (2nd Floor+)
0.29 Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade
Appliances Cooling System
BC665904
City Mailing Address of the Dwelling or Dwelling Unit
Combustion Air Select a Type
Location of duct or system:
17,800
Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel.Place your
logo here
New Construction Energy Code Compliance Certificate
Name of Residential Contractor
Mark Elliot Homes
MN License Number
Interior
Below Entire Slab Rigid, Extruded PolystyreneLakeville17809 Graphite Ln
THERMAL ENVELOPE RADON CONTROL SYSTEM
Total R-Value of all Types of InsulationType: Check All That Apply
Mineral FiberboardBuilders Associaton of Minnesota version 101014
NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION
This form must be completed and submitted with all new residential permit applications.
A National Pollutant Discharge Elimination System (NPDES) Construction Stormwater Permit is
required for “Construction activity that results in land disturbance of equal to or greater than one (1)
acre or if a project is part of a common plan of development that will ultimately disturb greater than
one (1) acre,” (NPDES Permit, Section 1.2).
Project Site Address: _____________________________________________________________________
Company Name: _________________________________________________________________________
*Primary Company Contact: _________________________________________________________________
*Should a site be deemed noncompliant, this individual will be notified
Phone #: ____________________________ Email: ______________________________________________
If you are not covered under a NPDES Construction Stormwater Permit administered by the
Minnesota Pollution Control Agency (MPCA), an erosion and sediment control plan MUST be
approved as part of the residential building permit application.
“Permittees must ensure a trained person will inspect the entire construction site at least once every
seven (7) days during active construction and within 24 hours after a rainfall event greater than ½
inch in 24 hours,” (NPDES Permit, Section 11.2).
The City of Lakeville reserves the right to request weekly inspection logs. The City of Lakeville may
issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to
bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or
erosion and sediment control plan.
Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control
inspections and corrective actions:
Name: ____________________________________ Company: ___________________________________
Phone # (24 hr Contact): ______________________ Email: ______________________________________
Entity that Provided Training: __________________________ Certification Expiration Date: ____________
NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed
I understand the above information to be accurate and I have read, understood, and accepted all terms and conditions of the NPDES Permit (MN R 100001).
Signature: ________________________________________________ Date:_________________________
Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500
X
KP
08/06/21