HomeMy WebLinkAboutLA200436-Approved Larson_Eng and Design Wyssling Consulting 76 North Meadowbrook Drive Alpine, UT 84004 Scott E. Wyssling, PE, PP, CME office (201) 874-3483 swyssling@wysslingconsulting.com August 3, 2021 DBM Solar Design and Consulting 2650 Washington Boulevard Ogden, UT 84412 Re: Engineering Services Larson Residence 20968 Hydra Court, Lakeville MN 5.625 kW System Size To Whom It May Concern: Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit/Verification Form prepared by a DBM Solar representative identifying specific site information including size and spacing of rafters for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information was prepared by DBM Solar and will be utilized for approval and construction of the proposed system. 3. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of truss system with all chords constructed of 2 x 4 dimensional lumber at 24” on center. The attic space is unfinished and photos indicate that there was free access to visually inspect the size and condition of the roof rafters. All wood material utilized for the roof system is assumed to be Doug-Fir #2 or better with standard construction components. The existing roofing material consists of composite asphalt shingles. Photos of the dwelling also indicate that there is a permanent foundation. A. Loading Criteria Used • 115 MPH wind loading based on ASCE 7-10 Exposure Category “B” at a slope of 28 degrees • 7 PSF = Dead Load roofing/framing Live Load = 20 PSF Snow Load = 50 PSF • 3 PSF = Dead Load solar panels/mounting hardware Total Dead Load =10 PSF The above values are within acceptable limits of recognized industry standards for similar structures in accordance with the 2020 Minnesota Residential Code. Analysis performed of the existing roof structure utilizing the above loading criteria indicates that the existing rafters will support the additional panel loading without damage, if installed correctly. Page 2 of 2 B. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent “Ironridge Installation Manual”, which can be found on the Ironridge website (http://ironridge.com/). If during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. Maximum allowable pullout per lag screw is 235 lbs/inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications for Doug-Fir (North Lumber) assumed. Based on our evaluation, the pullout value, utilizing a penetration depth of 2 ½”, is less than what is allowable per connection and therefore is adequate. Based on the variable factors for the existing roof framing and installation tolerances, using a thread depth of 2 ½” with a minimum size of 5/16” lag screw per attachment point for panel anchor mounts should be adequate with a sufficient factor of safety. 3. Considering the roof slopes, the size, spacing, condition of roof, the panel supports shall be placed no greater than 48” o/c. 4. Panel supports connections shall be staggered to distribute load to adjacent trusses. Based on the above evaluation, it is the opinion of this office that with appropriate connection being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is in conformance with the 2020 Minnesota Residential Code, current industry and standards, and based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Very truly yours, Scott E. Wyssling Minnesota License No. 57927 STREET VIEWAERIAL VIEW WIND SPEED: 115 MPH EXPOSURE CATEGORY: CA. ALL WORK SHALL COMPLY WITH STATE AND LOCAL CODES. B. DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. C. PRIOR TO COMMENCMENT OF WORK CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND NOTIFY DBM OF ANY INCONSISTENCIES. D. ALL EQUIPMENT SHALL BE INSTALLED AS SHOWN. F. WIRING SHALL NOT BE INSTALLED WITHIN 10 INCHES OF ROOF DECKING EXCEPT WHERE DIRECTLY BELOW PV EQUIPMENT SYSTEM SUMMARY DESIGN CRITERIA SCOPE OF WORK GENERAL NOTES OCCUPANCY & CONSTRUCTION TYPE OCCUPANCY - R3 CONSTRUCTION - V-B SHEET INDEX PAGE NUMBER PAGE TITLE PV01 TITLE PAGE PV02 SITE PLAN PV03 ONE LINE & ELECTRICAL PV04 ARRAY & STRINGING DETAIL PV05 LABEL PLAN SPECS SPECSHEETS AND DOCUMENTS 2020 Minnesota Building Code 2020 Minnesota Residential Code 2020 Minnesota Energy Code 2020 Minnesota Accessibility Code 2020 Minnesota Mechanical and Fuel Gas Code 2015 Minnesota Plumbing Code 2020 Minnesota Conservations Code 2020 Minnesota Fire Code Minnesota Electrical Code Minnesota Solar Energy Systems Code DC System Size: 5.625 kW Asphalt/Comp shingle roof pitch: 6/12 Anchored on 48 inch centers using UL listed racking system UV resistant cable ties (not zip ties) used for permanent wire management in accordance with (NEC 110.2,1110.3(A-B), 300.4) Junction boxes mounted flush w/racking APPLICABLE CODES E. WARNINGS PER NEC 690 AND IBC. Set Reviewed By: PV-041115-011207 INVERTER: (1) SOLAREDGE SE5000H-US String Inverter 240VAC RACKING: Ironridge Roof PV Mounting System OPTIMIZER: (15) SOLAREDGE P400 DC Optimizers MODULE: (15) JINKO SOLAR JKM375M-6RL3-B 375W PV Module 4778 N 300 W Suite 150, Provo, UT 84604 P: (801) 783-5959 CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT AVOLTA NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF DBM SOLAR DESIGN AND CONSULTING COMPANY, LLC SITE INFORMATION:Larson20968 Hydra CourtLakeville, MN 55044DC SYSTEM SIZE:5.625 kWDBM SOLAR DESIGN AND CONSULTING COMPANY, LLC P: (801) 690-4873 E: SUPPORT@DBMSOLAR.COM WWW.DBMSOLAR.COM PROJECT # DATE: DESIGNED BY: G. DAILY SHEET NAME: PAGE #REVISION: 0 2021-TOTAL 8/3/2021 PV01 COVER PAGE N PHOTOVOLTAIC MODULES 3' 18" 40" 73" FIRE CODE SETBACKS ARRAY DETAIL A B C D AZIMUTH 278° TILT ANGLE 28° MODULE COUNT 15 ROOF SUPPORTS Truss = 2X4 @ 24" O.C. SITE INDEX**Overhead Wires Must Have At Least 12" Clearance over all equipment, including PV panels** **PV Modules cannot be installed over vents **AC DISCONNECT LOCATED 10' OR LESS FROM UTILITY METER **WIRES LOCATED IN READILY ACCESSIBLE LOCATIONS SHALL BE GUARDED PER NEC 690.31(A)** **24/7 unescorted keyless access is required for ALL UTILITY EQUIPMENT Secondary Method of Interconnecting is: Supply Side Tap in MSP box OVERHEAD Service to home from the -E-282' Main Service Panel Located INTERIOR ACInv 12" *No clearance issue of over head power lines M MP 12" 6" (E) WALL Panels 10' *Distance between equipment not to Scale VISIBLE, LOCKABLE, LABELED AC DISCONNECT UTILITY METER INVERTER & DC DISCONNECT MSP(INTERIOR) UNDERGROUND SERVICE ENTRANCE No clearance issues. 7' 44'-3" 7'-1" 93'-8" 209'-7" 200'-10" 189'-3" R49'-6" 559'-6'' TRANSFORMER 282' 4778 N 300 W Suite 150, Provo, UT 84604 P: (801) 783-5959 CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT AVOLTA NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF DBM SOLAR DESIGN AND CONSULTING COMPANY, LLC SITE INFORMATION:Larson20968 Hydra CourtLakeville, MN 55044DC SYSTEM SIZE:5.625 kWDBM SOLAR DESIGN AND CONSULTING COMPANY, LLC P: (801) 690-4873 E: SUPPORT@DBMSOLAR.COM WWW.DBMSOLAR.COM PROJECT # DATE: DESIGNED BY: G. DAILY SHEET NAME: PAGE #REVISION: 0 2021-TOTAL 8/3/2021 PV02 PROPERTY DETAIL JUNCTION BOX +- ELECTRICAL NOTES INVERTER SPECIFICATIONS MANUFACTURER SolarEdge MODEL SE5000H-US (240V) MAX DC INPUT VOLTAGE 480 V MAX OUTPUT POWER 5000 W NOMINAL AC OUTPUT VOLTAGE 240 V NOMINAL AC OUTPUT CURRENT 21 AMAX FUSE (OCPD)30 A PHOTOVOLTAIC AC OUTPUT LABEL AC OUTPUT CURRENT 21A NOMINAL AC VOLTAGE 240V #10 PV WIRE #6 BARE COPPER EGC 1 2 3 A.ALL COMPONENTS SHALL COMPLY WITH NEC AS AMENDED. B.PHASE CONDUCTORS SHALL BE IDENTIFIEDC.ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF UPON ENTRY INTO BOXES, REFER TO MANUFACTURERS INSTALLATION MANUAL FOR REQUIRED TORQUE VALUES D.THE DC GEC, IF USED, SHALL BE CONTINUOUS FROM THE INVERTER GROUND BUS TO THE MAIN SERVICE GROUNDING ELECTRODE SYSTEM E.ATTACHMENT TO GROUND ELECTRODE SHALL USE IRREVERSIBLE CLAMP. F.ALL EXPOSED METAL PARTS SHALL BE GROUNDED USING TIN PLATED COPPER LAY IN LUGS OR GROUNDING CLIPS LISTED FOR THE PURPOSE G.MIN #10 BARE COPPER EGC AT SOURCE CIRCUITS SHALL BE ROUTED SECURELY TO MOUNTING HARDWARE THAT PROTECTS FROM PHYSICAL DAMAGEH.#6 FOR AREAS THAT MAY BE SUBJECT TO DAMAGE I.BOTH ENDS OF ALL METALLIC CONDUIT SHALL BE BONDED PER NEC 250 J.INTERCONNECTION PER NEC 690K.ALL WIRES WILL BE RATED AT THHN/THWN-2 L.PV PRODUCTION TERMINATED IN LOAD SIDES OF ALL AC DISCONNECTS M.CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS 4 RAPID SHUTDOWN DEVICE DC DISCONNECT MODULES & OPTIMIZERS IN A SERIES STRING15 *DC OPTIMIZERS OUTPUT 1Voc PER MODULE & KEEP VOLTAGE AT MAX POWER POINT VOLTAGE OF THE INVERTER* 200A MAIN BUS200A MAIN OCPD MAIN SERVICE PANEL UTILITY METER SE5000H-US NON-FUSED AC DISCONNECT30A 120/240V Shall be Visible-Open Type, Lockable PV LOAD CALCULATIONS 200A RATED MAIN PANEL 200A * 120% = 240A 240A - 200A = 40A (MAIN BUS ALLOWABLE SOLAR) 40A AVAILABLE FOR PV 705.12(B)(2) ·All Exposed PV rooftop conductors that are not located under the array modules, shall be installed in a listed raceway, and shall include listed junction boxes at both ends of the raceway to transition from exposed conductors to the listed raceways. In Accordance with NEC 690.31(A) & (B)** ·ROMEX AMPACITY LIMITED TO 60° VALUES. IF USED, SIZE ACCORDING TO NEC TABLE 310.15 ·DC Conduit must be marked in accordance with NEC 690.31. Labeling must be every 10' and must comply with NEC 690.31. See PV05 for Label plan ·ALL DC Conductors must be protected with metal conduit TYPICAL LOAD SIDE CONNECTION NEC 705.12 (B)(2) PV BREAKER LOCATED OPPOSITE MAIN BREAKER UTILITY AC DISCONNECT 30A-2PPV BREAKER 200AMAIN BREAKER #XX XXX XXX INTEGRATED ARC FAULT PROTECTION AND RAPID SHUTDOWN FOR NEC 2020 690.11 AND 690.12 CONDUCTOR SCHEDULE WITH NEC ELECTRICAL CALCULATIONS ID DESCRIPTION CONDUCTOR CONDUIT NO. OF CNDRS. IN CNDT. RATED AMPS EGC TEMP. CORR. FACTOR FILL ADJ. FACTOR CONT. CURRENT MAX. CURRENT BASE AMPACITY DERATED AMPACITY WIRE RUN DISTANCE 1 DC CIRCUIT: SERIES STRING OUTPUT TO JUNCTION BOX PV WIRE FREE AIR N/A 15.00A #6 BARE COPPER 0.96 N/A 15.00A 18.75A 35A 33.60A 20ft 2 DC CIRCUIT (TRANSITIONED): JUNCTION BOX TO INVERTER 10 AWG THWN-2 COPPER 3/4" DIA EMT 2 15.00A 10 AWG THWN-2 COPPER 0.96 1 15.00A 18.75A 35A 33.60A 20ft 3 INVERTER TO AC DISCONNECT 10 AWG THWN-2 COPPER 3/4" DIA EMT 3 21.00A 10 AWG THWN-2 COPPER 0.96 1.0 21.00A 26.25A 35A 33.60A 5ft 4 AC DISCONNECT TO PRODUCTION METER 10 AWG THWN-2 COPPER 3/4" DIA EMT 3 21.00A 10 AWG THWN-2 COPPER 0.96 1.0 21.00A 26.25A 35A 33.60A 5ft 5 PRODUCTION METER TO POINT OF INTERCONNECTION 10 AWG THWN-2 COPPER 3/4" DIA EMT 3 21.00A 10 AWG THWN-2 COPPER 0.96 1.0 21.00A 26.25A 35A 33.60A 5ft G #6 CU GEC MAX DC VOLTAGE =480V MAX DC CIRCUIT CURRENT = MAXIMUM RATED DC OUTPUT CURRENT OF DC TO DCCONVERTER (IF INSTALLED) = DC DISCONNECT CALCS 15A 15A PV MODULE SPECIFICATIONSMANUFACTURERJINKO SOLAR MODEL JKM375M-6RL3-BMAX POWER-POINT VOLTAGE (Vmp)36.80VMAX POWER-POINT CURRENT (Imp)10.19AOPEN CIRCUIT VOLTAGE (Voc)44.12VSHORT CIRCUIT CURRENT (Isc)11.01AMAX SERIES FUSE (OCPD)20AMAX POWER (Pmax)375WMAX VOLTAGE (Vdc)1000V *SECONDARY INTERCONNECTION METHOD IS LOAD SIDE BREAKER* 1-ph Utility Interactive Inverter SolarEdge 5000H-US UL 1741 SA Certified and readily accessible Bi-Directional by Xcel Energy1-ph 120/240V - 200A self contained Reference point of accessiblilty as per IEEE 1547 4778 N 300 W Suite 150, Provo, UT 84604 P: (801) 783-5959 CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT AVOLTA NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF DBM SOLAR DESIGN AND CONSULTING COMPANY, LLC SITE INFORMATION:Larson20968 Hydra CourtLakeville, MN 55044DC SYSTEM SIZE:5.625 kWDBM SOLAR DESIGN AND CONSULTING COMPANY, LLC P: (801) 690-4873 E: SUPPORT@DBMSOLAR.COM WWW.DBMSOLAR.COM PROJECT # DATE: DESIGNED BY: G. DAILY SHEET NAME: PAGE #REVISION: 0 2021-TOTAL 8/3/2021 PV03 1LD/ ELECTRICAL DETAIL 3" 4" + -+ -+ -+ - Diagram: Grid-Tied System w/ Optimizers + -+ -+ - PV Source Circuit To Inverter Junction Box #10 PV Wire Equipment Grounding Conductor Solar Edge DC Optimizers Attachment Diagram 48" MAX rail span with staggered attachments to distribute weight across support framing Rail PV Module Module Overhang Cantilever = 33% of MAX rail span 25% 25% 50% ROOF SURFACE FLASHING 5/16" STAINLESS STEEL LAG BOLT AND FLAT WASHER SOLAR MODULE 5'5" 4' 4" NOTE: FOR MORE DETAILS SEE NEC 690.31 (E)(1) 4" BETWEEN ROOF AND PANELS JUNCTION BOX Photovoltaic Array String Detail (15) Modules String A GROUNDING DETAIL PV ATTIC DETAIL ATTACHMENT DETAIL *See Attached Data Sheets For More Information STRINGING DETAIL RAIL MOUNT TERMINAL BLOCK HEYCO-TITE UL LISTED/RECOGNIZED AND CSA CERTIFIED LIQUID TIGHT CORDGRIPS A 4778 N 300 W Suite 150, Provo, UT 84604 P: (801) 783-5959 CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT AVOLTA NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF DBM SOLAR DESIGN AND CONSULTING COMPANY, LLC SITE INFORMATION:Larson20968 Hydra CourtLakeville, MN 55044DC SYSTEM SIZE:5.625 kWDBM SOLAR DESIGN AND CONSULTING COMPANY, LLC P: (801) 690-4873 E: SUPPORT@DBMSOLAR.COM WWW.DBMSOLAR.COM PROJECT # DATE: DESIGNED BY: G. DAILY SHEET NAME: PAGE #REVISION: 0 2021-TOTAL 8/3/2021 PV04 ARRAY/STRINGING DETAIL LOCATION: (1) COMBINER BOX (2) JUNCTION BOX LOCATION: STRING INVERTER (IF USED) LOCATION: MAIN SERVICE LOCATION: (1) MAIN SERVICE (3) BREAKER PANEL (4) DISCONNECT SWITCH LOCATION: DC CONDUIT (EVERY 10 FEET) (REFLECTIVE CONDUIT LABEL) PER NEC 690.31(B)(1-4)LOCATION: (1) MAIN SERVICE (5) INVERTER (IF USED) (2) AC COMBINER PANEL MAIN SERVICE & ALL BACK FED PANEL BOARDS LOCATION: (1) MAIN SERVICE (2) AC COMBINER PANEL (3) ALL BACKFED PANELS I LABEL NOTESLABEL NOTES 4.5" H 4.5" 4.5" 4.5" 3" 4.5" FE DCBA MAIN SERVICE PANEL FOR ILLUSTRATION ONLY (NOT ACTUAL MSP) PV SUB PANEL (IF USED) AC DISCONNECT (IF USED) STRING INVERTER (IF USED) JUNCTION BOX A A A AC D E H G H A F I I J J FOR MICRO INVERTERS ONLY (NO KNIFE SWITCH DISCONNECT) J 4.5" PHOTOVOLTAIC UTILITY AC DISCONNECT MAXIMUM AC OPERATING CURRENT: NOMINAL AC OPERATING VOLTAGE: J G 21A 240V TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY K SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS (2017 NEC 690.56(C)(1)(a)) (YELLOW WITH BLACK LETTERING) K WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION WARNING: PHOTOVOLTAIC POWER SOURCE WARNING: DUAL POWER SOURCE SECOND SOURCE IS A PHOTOVOLTAIC SYSTEM "RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM" "PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN" WARNING: DO NOT ADD ADDITIONAL CIRCUITS TO PANEL CAUTION: PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED WARNING: INVERTER OUTPUT CONNECTION DO NOT RELOCATE SOLAR BREAKER A.RED BACKGROUND WITH WHITE LETTERING OR YELLOW / ORANGE BACKGROUND WITH BLACK LETTERING B.MINIMUM 3/8" LETTER HEIGHT C.ALL CAPITAL LETTERS D.NON BOLD TEXT E.MATERIAL SUITABLE FOR ENVIRONMENT F.SIGNS MUST BE REFLECTIVE G.SIGNS MUST NOT BE HAND WRITTEN MAX DC VOLTAGE =480V MAX DC CIRCUIT CURRENT = MAXIMUM RATED DC OUTPUT CURRENT OF DC TO DC CONVERTER (IF INSTALLED) = DC DISCONNECT CALCS 15A 15A PV Production Meter (if used) L "PV PRODUCTION METER" L Labels Shall be WEATHERPROOF, DURABLE and PERMANENTLY MOUNTED - Labels should comply with NEC 690 M "BI DIRECTIONAL METER" M 4778 N 300 W Suite 150, Provo, UT 84604 P: (801) 783-5959 CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT AVOLTA NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF DBM SOLAR DESIGN AND CONSULTING COMPANY, LLC SITE INFORMATION:Larson20968 Hydra CourtLakeville, MN 55044DC SYSTEM SIZE:5.625 kWDBM SOLAR DESIGN AND CONSULTING COMPANY, LLC P: (801) 690-4873 E: SUPPORT@DBMSOLAR.COM WWW.DBMSOLAR.COM PROJECT # DATE: DESIGNED BY: G. DAILY SHEET NAME: PAGE #REVISION: 0 2021-TOTAL 8/3/2021 PV05 LABEL PLAN PICTURES 4778 N 300 W Suite 150, Provo, UT 84604 P: (801) 783-5959 CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT AVOLTA NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF DBM SOLAR DESIGN AND CONSULTING COMPANY, LLC SITE INFORMATION:Larson20968 Hydra CourtLakeville, MN 55044DC SYSTEM SIZE:5.625 kWDBM SOLAR DESIGN AND CONSULTING COMPANY, LLC P: (801) 690-4873 E: SUPPORT@DBMSOLAR.COM WWW.DBMSOLAR.COM PROJECT # DATE: DESIGNED BY: G. DAILY SHEET NAME: PAGE #REVISION: 0 2021-TOTAL 8/3/2021 PICS PICTURES SOLAR MODULE SPECSHEET 4778 N 300 W Suite 150, Provo, UT 84604 P: (801) 783-5959 CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT AVOLTA NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF DBM SOLAR DESIGN AND CONSULTING COMPANY, LLC SITE INFORMATION:Larson20968 Hydra CourtLakeville, MN 55044DC SYSTEM SIZE:5.625 kWDBM SOLAR DESIGN AND CONSULTING COMPANY, LLC P: (801) 690-4873 E: SUPPORT@DBMSOLAR.COM WWW.DBMSOLAR.COM PROJECT # DATE: DESIGNED BY: G. DAILY SHEET NAME: PAGE #REVISION: 0 2021-TOTAL 8/3/2021 SPECS SPEC SHEETS INVERTER SPECSHEET 4778 N 300 W Suite 150, Provo, UT 84604 P: (801) 783-5959 CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT AVOLTA NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF DBM SOLAR DESIGN AND CONSULTING COMPANY, LLC SITE INFORMATION:Larson20968 Hydra CourtLakeville, MN 55044DC SYSTEM SIZE:5.625 kWDBM SOLAR DESIGN AND CONSULTING COMPANY, LLC P: (801) 690-4873 E: SUPPORT@DBMSOLAR.COM WWW.DBMSOLAR.COM PROJECT # DATE: DESIGNED BY: G. DAILY SHEET NAME: PAGE #REVISION: 0 2021-TOTAL 8/3/2021 SPECS SPEC SHEETS OPTIMIZER SPECSHEET 4778 N 300 W Suite 150, Provo, UT 84604 P: (801) 783-5959 CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT AVOLTA NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF DBM SOLAR DESIGN AND CONSULTING COMPANY, LLC SITE INFORMATION:Larson20968 Hydra CourtLakeville, MN 55044DC SYSTEM SIZE:5.625 kWDBM SOLAR DESIGN AND CONSULTING COMPANY, LLC P: (801) 690-4873 E: SUPPORT@DBMSOLAR.COM WWW.DBMSOLAR.COM PROJECT # DATE: DESIGNED BY: G. DAILY SHEET NAME: PAGE #REVISION: 0 2021-TOTAL 8/3/2021 SPECS SPEC SHEETS RACKING SPECSHEET 4778 N 300 W Suite 150, Provo, UT 84604 P: (801) 783-5959 CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT AVOLTA NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF DBM SOLAR DESIGN AND CONSULTING COMPANY, LLC SITE INFORMATION:Larson20968 Hydra CourtLakeville, MN 55044DC SYSTEM SIZE:5.625 kWDBM SOLAR DESIGN AND CONSULTING COMPANY, LLC P: (801) 690-4873 E: SUPPORT@DBMSOLAR.COM WWW.DBMSOLAR.COM PROJECT # DATE: DESIGNED BY: G. DAILY SHEET NAME: PAGE #REVISION: 0 2021-TOTAL 8/3/2021 SPECS SPEC SHEETS 4778 N 300 W Suite 150, Provo, UT 84604 P: (801) 783-5959 CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT AVOLTA NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF DBM SOLAR DESIGN AND CONSULTING COMPANY, LLC SITE INFORMATION:Larson20968 Hydra CourtLakeville, MN 55044DC SYSTEM SIZE:5.625 kWDBM SOLAR DESIGN AND CONSULTING COMPANY, LLC P: (801) 690-4873 E: SUPPORT@DBMSOLAR.COM WWW.DBMSOLAR.COM PROJECT # DATE: DESIGNED BY: G. DAILY SHEET NAME: PAGE #REVISION: 0 2021-TOTAL 8/3/2021 SPECS SPEC SHEETS