Loading...
HomeMy WebLinkAboutLA200384 -17936 Evershed Way Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: 17936 EVERSHED WAY, LAKEVILLE*ALL DOOR & WINDOW HEADERSTO BE S.P.F. #2 OR BETTERRESIDENCE FOR:written consent of Planco MN, Inc. modified or used in any redesign without the priormay not be assigned or copied, and may not bemay not be re-used for any additional structures,structure. Planco MN reserves all rights. These planslicense is granted to use these plans to build oneCopyright for these drawings is owned by Planco MN,Planco MN, Inc.cKEN PAGEL & RYAN JOOSTBERNS#22-003SMA172022LOT 2, BLOCK 2, KNOB HILL OF LAKEVILLE 3RD ADDITION STONE COTTAGE CONSTRUCTION, INC. FRONT ELEVATION 1/4" = 1'-0" 9' POURED FOUNDATION9' CEILING @ FIRST FLOOR9x7 OVH. DR.16x7 OVH. DR.VINYLB & BVINYLB & B1'-6"VINYLSIDING4" TRIMSTONECAPSTONE4" TRIM12x12 BOXEDCOLUMNCONC. PORCH812612612VINYL B & BSIMONTON WDWS.STONE AS SHOWNFRONT ONLYGRIDS IN WDWS.FRONT & LEFT SIDEFRONT ONLY4" EXPOSURE VINYL SIDINGALL SIDESALUM. SOFFIT & FASCIAALL SIDESSTONEON JOGTOTALBSM'T1st FLR.1,514 SQ. FT.942 SQ. FT.2,456 SQ. FT.FRONT ONLY4" VINYL TRIMConcept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode03/22/2022dmathews VERIFY ALLGRADE LINESPlanco MN, Inc.C#22-003SMA272022 LEFT ELEVATION 1/8" = 1'-0" VINYLCORNERSSIDINGVINYL SIDINGVINYL1261'-5" RIGHT ELEVATION 1/8" = 1'-0" VINYLCORNERSSIDINGVINYL SIDINGVINYL 1268122'-0"8/12 REAR ELEVATION 1/8" = 1'-0" VINYLCORNERSSIDINGVINYL 1261'-0" ROOF PLAN 1/8" = 1'-0" 1'-5"1261261268128128/12 1'-6"1'-0"2'-0"2'-0"1'-6"1'-0" Planco MN, Inc.C#22-003SMA372022 BASEMENT PLAN 1/4" = 1'-0" 9' POURED FOUNDATIONUP16 R UNEXCAVATED UNEXCAVATED 506826682-2x101/2 WALLBM.PKT.LOOKOUT LOOKOUT TRT. 4x4 CURB2x4 - 16" O.C.16x8 FTG.TRT. 4x4 CURB2x4 - 16" O.C.16x8 FTG.TRT. 4x4 CURB2x4 - 16" O.C.16x8 FTG.2-2x105/0x3/6 SL WALKOUTWALKOUT2-2x106068 P.D.3-2x106/0x5/0 SL*UNFINISHED MECH/STORAGE WHFURNF.D.92%SUMP286811 7/8" I JTS. 19.2" O.C. 11 7/8" LSL 16" O.C. 11 7/8" LSL 19.2" O.C.*CARPET FAMILY/REC ROOM 4x4 POSTON 30"x30"x12"CONC. PAD FTG.40'-0" 2'-0"30'-0"20'-0"13'-0"19'-0"11'-0"52'-0" 22'-6"29'-6" 14'-0"15'-6"20'-6"2'-0"7'-0"42'-0"4'-0"25'-6"4'-0"8'-0"1'-0"4'-6"2" LEDGE2" LEDGE6'-11"14'-1"15'-0"6'-0"12'-0"2'-6"27'-6"7'-6"4'-0" 9'-2"3'-8" I.D.17'-2"13'-2"12'-6"5'-8"SD/CORADONVENT2-2x106/0x5/0 SL2-9 1/2" LVL DROPPED2-2x8 FLUSH1-11 7/8" LSLFLUSH14'-0"26685068286824684834F54"18"x24"LIN.1 PIECE FIB.*VINYL BEDROOM #4 BEDROOM #3 *CARPET*CARPETGASF.P.1'-8"5'-6"6'-4"SDSD2-2x10TRT. 4x4 CURB2x4 - 16" O.C.16x8 FTG.7'-6"3'-6"3'-8"11'-0"14'-8"11'-4"2'-6"11'-6"5'-8"5'-8" 3'-0"*UNFINISHED STORAGE 2x6”),1,6+('64)7 (;&/8'(667$,56 *20x10 PATIO 12'-0"TRT. 2-2x8FLUSH112"4'-0"TREATED2x816" O.C.TRT. 3-2x12 FLUSHTREATED 2x10 16" O.C.TRT. 6x6 POSTON 18"x42" CONC.TUBE FTG.4'-0"14'-0"SOFFIT ABOVESHOWER2-2x10DROPPED1'-8"20"x20" Pads3333UFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. Planco MN, Inc.C#22-003SMA472022 FIRST FLOOR PLAN 1/4" = 1'-0" GASF.P.1'-8"3'-10"6'-4"7'-0"3'-8" I.D.RAIL10"DN16 R10'-2"286850682868 C.O.2868FIREDOOR2868PKT.WD24682468 C.O.603478"24682068LIN.2'-0"2/6x4/0 SH 2-2x10 9/0x5/0 SL2-9 1/2" LVL2-9 1/2" LSL6068 P.D.5'-0" TUB& SHOWER1 PIECE FIB.60"2'-6"F*VINYL24"x21"LIN.CAB.2468506826683068SLSL12" SOFFIT8"4'-0"8"REF'G11'-0"10'-1"5'-5"2'-6"11'-0"S.B.4'-0"7'-6" CAB.4'-0" 1'-0"*CARPET MASTER BEDROOM *WOOD GREAT ROOM *WOOD DINING KITCHEN *WOOD FOYER *WOOD OFFICE/BEDROOM #2 *CARPET W.I.C. *CARPET MUD RM *VINYL LNDRY *VINYL*C.T.FC.T. WALLSFIB. BASESDSD/COTRUSSES 24" O.C. GARAGE *4" CONC. FLOOR*2x6 WALLSTRUSSES24" O.C.9x7 OVH. DR.2-2x12 16x7 OVH. DR.2-11 7/8" LSL 20' LONG40'-0"REF'GRECESS2x62'-0"8'-2"3'-4"4'-8"9'-2"3'-6"30'-0"20'-0"13'-0"19'-0"11'-0"5'-11"5'-1"9'-6"9'-6"52'-0" 22'-6"29'-6" 14'-0"15'-6"20'-6"2'-0"7'-0"6/0x5/0 SL2-9 1/2" LSL2-2x86"12x12 BOXEDCOLUMN4'-0"1,514 SQ. FT.9' CEILING @ FIRST FLOOR42'-0"28'-6"13'-6"6'-11"6'-7"9'-0"13'-6"6'-0"4'-0"25'-6"4'-0"11'-6"5'-6"8'-6"2-2x103-2x106'-6"8'-0" CONC. PORCH 6'-6"2'-8" 7'-0"8'-6" 3'-7"4'-11"9'-6"4'-0"SLOPE FLOORFOR HDRM2x2ACCESS ATTIC12" SOFFIT1'-0"4"6'-6"4"2x2WALLHUNG LTGLASSPANELGYP. BD.SDSDRADONVENTGIRDER 2-9 1/2" LSL7/6x5/0 SL14'-0"4'-3"4'-3"206816" SH'SPANT.*WOOD5'-9"5'-3"2-2x106/0x2/0 FXMICRO RANGE W/HOODVENT3'-0"*INSUL. WALLS & CLG.44 1/2" TALLWALL W/ WD. CAPCAB.PANELDNTO GRADE *12x14 DECK 50'-0"Temper2.52.5333333333385PFHPFHCO-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ). Planco MN, Inc.C#22-003SMA572022 CROSS SECTION 3/8" = 1'-0" SHEATHINGSIDING1-2x6 TREATEDR-21 INSUL.9'-11 8"3 1/2" CONC. FLOORR-20 SPRAY FOAM1/2" GYP. BD.VB11 7/8" LSL JTS. @ 16" O.C.8-'4" POURED “WALL W/ REBARPER CODE3/4" T & G FLOORSILL PLATE2x6- 16" O.C.38'-0"5/8" GYP. BD.W/ V.B.2x6- 16" O.C.VB1/2" GYP. BD.R-21 INSUL.SIDINGSHEATHING(DESIGNED BY MFR)TRUSSES @ 24" O.C.R-49 INSUL.WATERPROOFINGGRADE6'-0"6'-6"R-10 W/ <2.6 ACHINSUL.TRT. 6x6 POST GREAT ROOM HOUSEWRAPHOUSEWRAPFASCIAALUM. ALUM.SOFFITVENTED2'-0"ENERGY HEELFASCIAALUM. ALUM.SOFFITVENTED1'-5"2-2x8POURED WALLGRADE2" FOAM758"2" FOAM W/“%(9(/512"4'-0"1/2" SHTG.15# FELTSHINGLESROOF VENTS @ 1/300 ATTIC50% ROOF 50% SOFFITFOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECSFOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECSCONC. PORCHTRT. 4x4 CURB2x4- 16" O.C.16x8 FOYER 612DRAIN TILE 11 7/8" I JTS. @ 19.2" O.C.R-21 INSUL.1/2" GYP. BD.VB2x6- 16" O.C.5/8" GYP. BD. Planco MN, Inc.C#22-003SMA672022 CROSS SECTION 3/8" = 1'-0" SHEATHINGSIDING1-2x6 TREATEDR-20 SPRAY FOAMR-21 INSUL.9'-11 8"3 1/2" CONC. FLOORR-20 SPRAY FOAM1/2" GYP. BD.VB11 7/8" I JTS. @ 19.2" O.C.8'-4" POURED “WALL W/ REBARPER CODE3/4" T & G FLOORSILL PLATE2x6- 16" O.C.30'-0"5/8" GYP. BD.W/ V.B.2x6- 16" O.C.VB1/2" GYP. BD.R-21 INSUL.(DESIGNED BY MFR)TRUSSES @ 24" O.C.R-49 INSUL.WATERPROOFING4" CONC. FLOOR GARAGE GRADEPOURED WALL2X6- 16" O.C.22'-0"SLOPE(DESIGNED BY MFR)TRUSSES @ 24" O.C.R-10 W/ <2.6 ACHINSUL.1/2" GYP. BD.HOUSEWRAPSIDINGSHEATHINGHOUSEWRAPFASCIAALUM. ALUM.SOFFITVENTED1/2" SHTG.15# FELTSHINGLES2'-0"ENERGY HEELTRT. 4x4 CURB2x4- 16" O.C.16x8POURED WALLGRADE2" FOAM758"2" FOAM W/“%(9(/512"4'-0"R-21 INSUL.1/2" GYP. BD.VB2x6- 16" O.C.612ROOF VENTS @ 1/300 ATTIC50% ROOF 50% SOFFIT21'-812"DRAIN TILE FOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECSFOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECSFOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECS16x873 8" 15 RISERSTRT. 4x4 CURB2x4- 16" O.C. GREAT ROOM MUD ROOM 6'-8" MIN. HDRM1x8 RISERS5/4x11 TREADS4- 2x12 STRINGERSTAIR NOTES:10" ROUGH CUT TREADS11 7/8" LSL JTS. @ 19.2" O.C.5/8" GYP. BD. Planco MN, Inc.C#22-003SMA772022FLOOR SYSTEMROOFTRUSSPVC T-FITTINGTO SUPPORTVENT PIPEMIN. 4" OF GASPERMEABLE MATERIAL3 1/2" CONC. SLAB4" PVC VENT PIPESUPPORTSTRAPPINGFLASHINGEXHAUST 10' FROM OPNGS.INTO CONDITIONED SPACESOF BUILDING12" MIN. ABOVE ROOFSEAL6 MIL POLYUNDER SLAB10' OF DRAIN TILEEACH WAY FROMT-FITTING(ROCK) RADON GAS VENT SYSTEM 3/8" = 1'-0" 36" MIN. HT. CLEAR SPACE24" DIA. AROUND VENTPROVIDE ELECTRICALBOX POWER SOURCER-4 MIN. INSUL. VENT PIPE@ UNCONDITIONED SPACE4" MIN. CLEARANCEFOR FUT. FAN6'-8" MIN. HDRM1x8 RISERS5/4x11 TREADS4- 2x12 STRINGERSTAIR NOTES:10" ROUGH CUT TREADS10"73 8" 6'-10"2-2x8 CROSS SECTION 3/8" = 1'-0" 1-11 7/8" LSL BASEMENT PLAN 1/4" = 1'-0" 9' POURED FOUNDATIONUP16 R UNEXCAVATED UNEXCAVATED 506826682-2x101/2 WALLBM.PKT.LOOKOUT LOOKOUT TRT. 4x4 CURB2x4 - 16" O.C.16x8 FTG.TRT. 4x4 CURB2x4 - 16" O.C.16x8 FTG.TRT. 4x4 CURB2x4 - 16" O.C.16x8 FTG.2-2x105/0x3/6 SL WALKOUTWALKOUT3-2x106068 P.D.3-2x106/0x5/0 SL*UNFINISHED MECH/STORAGE WHFURNF.D.92%SUMP286811 7/8" I JTS. 19.2" O.C. 11 7/8" LSL 16" O.C. 11 7/8" LSL 19.2" O.C.*CARPET FAMILY/REC ROOM 4x4 POSTON 30"x30"x12"CONC. PAD FTG.40'-0" 2'-0"30'-0"20'-0"13'-0"19'-0"11'-0"52'-0" 22'-6"29'-6" 14'-0"15'-6"20'-6"2'-0"7'-0"42'-0"4'-0"25'-6"4'-0"8'-0"1'-0"4'-6"2" LEDGE2" LEDGE6'-11"14'-1"15'-0"6'-0"12'-0"2'-6"27'-6"7'-6"4'-0" 9'-2"3'-8" I.D.17'-2"13'-2"12'-6"5'-8"SD/CORADONVENT2-2x106/0x5/0 SL2-11 7/8" LVL DROPPED2-2x8 FLUSH1-11 7/8" LSLFLUSH14'-0"26685068286824684834F54"18"x24"LIN.1 PIECE FIB.*VINYL BEDROOM #4 BEDROOM #3 *CARPET*CARPETGASF.P.1'-8"5'-6"6'-4"SDSD2-2x10DROPPEDTRT. 4x4 CURB2x4 - 16" O.C.16x8 FTG.7'-6"3'-6"3'-8"11'-0"14'-8"11'-4"2'-6"11'-6"5'-8"5'-8" 3'-0"*UNFINISHED STORAGE 2x6*20x10 PATIO 12'-0"TRT. 2-2x8FLUSH112"4'-0"TREATED2x816" O.C.TRT. 3-2x12 FLUSHTREATED 2x10 16" O.C.TRT. 6x6 POSTON 18"x42" CONC.TUBE FTG.4'-0"14'-0"SOFFIT ABOVESHOWER20'BWL 13'3'3'3' FIRST FLOOR PLAN 1/4" = 1'-0" GASF.P.1'-8"3'-10"6'-4"7'-0"3'-8" I.D.RAIL10"DN16 R10'-2"286850682868 C.O.2868FIREDOOR2868PKT.WD24682468 C.O.603478"24682068LIN.2'-0"2/6x4/0 SH 2-2x10 9/0x5/0 SL2-9 1/2" LVL2-9 1/2" LSL6068 P.D.5'-0" TUB& SHOWER1 PIECE FIB.60"2'-6"F*VINYL24"x21"LIN.CAB.2468506826683068SLSL12" SOFFIT8"4'-0"8"REF'G11'-0"10'-1"5'-5"2'-6"11'-0"S.B.4'-0"7'-6" CAB.4'-0" 1'-0"*CARPET MASTER BEDROOM *WOOD GREAT ROOM *WOOD DINING KITCHEN *WOOD FOYER *WOOD OFFICE/BEDROOM #2 *CARPET W.I.C. *CARPET MUD RM *VINYL LNDRY *VINYL*C.T.FC.T. WALLSFIB. BASESDSD/COTRUSSES 24" O.C. GARAGE *4" CONC. FLOOR*2x6 WALLSTRUSSES24" O.C.9x7 OVH. DR.2-2x12 16x7 OVH. DR.2-11 7/8" LSL 20' LONG40'-0"REF'GRECESS2x62'-0"8'-2"3'-4"4'-8"9'-2"3'-6"30'-0"20'-0"13'-0"19'-0"11'-0"5'-11"5'-1"9'-6"9'-6"52'-0" 22'-6"29'-6" 14'-0"15'-6"20'-6"2'-0"7'-0"6/0x5/0 SL2-9 1/2" LSL2-2x86"12x12 BOXEDCOLUMN4'-0"1,514 SQ. FT.9' CEILING @ FIRST FLOOR42'-0"28'-6"13'-6"6'-11"6'-7"9'-0"13'-6"6'-0"4'-0"25'-6"4'-0"11'-6"5'-6"8'-6"2-2x103-9 1/2" LSL6'-6"8'-0" CONC. PORCH 6'-6"2'-8" 7'-0"8'-6" 3'-7"4'-11"9'-6"4'-0"SLOPE FLOORFOR HDRM2x2ACCESS ATTIC12" SOFFIT1'-0"4"6'-6"4"2x2WALLHUNG LTGLASSPANELGYP. BD.SDSDRADONVENTGIRDER 3-2x107/6x5/0 SL14'-0"4'-3"4'-3"206816" SH'SPANT.*WOOD5'-9"5'-3"2-2x106/0x2/0 FXMICRO RANGE W/HOODVENT3'-0"*INSUL. WALLS & CLG.44 1/2" TALLWALL W/ WD. CAPCAB.PANELDNTO GRADE *12x14 DECK 50'-0"25'25'45'BWL 4BWL 3BWL 2BWL 5BWL 63'3'3'2'-6"SEE DETAIL 1/PF-14'8'5'3'3'3'3'3'3'3'2'-6" Voigt & Associates, Inc.C-1Structural Engineering Services 4635 Nicols Road, Suite 204Eagan, MN 55122MethodCS-WSPWind speed 115Exposure CGB BWL 1 2 3 4 5 6Spacing - ft 20 25 25 25 45 45Level 2 1 1 1 1 1Length req'd- ft 6.5 4 8 4 6.8 6.8per Table R602.10.3(1)Adjustments:Exposure 1.2 1.2 1.2 1.2 1.2 1.2Eave to ridge Height 1.11 1.22 1.22 1.22 1.22 1.22 Wall Height 0.9 0.95 0.95 0.95 0.95 0.95# of BWL 1 1.3 1.3 1.3 1 14" Gyp WB w.block joints1 1 1 1 1 1Adjusted Length 7.8 7.2 14.5 7.2 9.5 9.5Pagel & Joostberns Residence17936 Evershed Way, Lakeville, MN Sheet Stone Cottage HVAC Load Calculations for Pagel-joostberns 17936 Evershed Way Lakeville,mn Prepared By: Randy Andrews Lofgren Heating 5708 Upper 147th Street West Apple Vallley, MN 55124 Tuesday, February 8, 2022 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 2 Project Report General Project Information Project Title:Stone Cottage Project Date:Tuesday, February 8, 2022 Client Name:Pagel-joostberns Client Address:17936 Evershed Way Client City:Lakeville,mn Company Name:Lofgren Heating Company Representative:Randy Andrews Company Address:5708 Upper 147th Street West Company City:Apple Vallley, MN 55124 Company E-Mail Address:rrandrews@lofgrenheating-ac.com Design Data Reference City:Minneapolis, Minnesota Building Orientation:Front door faces West Daily Temperature Range:Medium Latitude:44 Degrees Elevation:834 ft. Altitude Factor:0.970 Elevation Sensible Adj. Factor:1.000 Elevation Total Adj. Factor:1.000 Elevation Heating Adj. Factor:1.000 Elevation Heating Adj. Factor:1.000 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter:-15 -15.33 80%n/a 72 n/a Summer:88 72 47%50%75 29 Check Figures Total Building Supply CFM:1,212 CFM Per Square ft.:0.400 Square ft. of Room Area:3,028 Square ft. Per Ton:1,147 Volume (ft³) of Cond. Space:27,252 Building Loads Total Heating Required Including Ventilation Air:43,316 Btuh 43.316 MBH Total Sensible Gain:26,316 Btuh 83 % Total Latent Gain:5,374 Btuh 17 % Total Cooling Required Including Ventilation Air:31,690 Btuh 2.64 Tons (Based On Sensible + Latent) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\17936 EVERSHED LAKEVILLE RAMBLER 02082022.rhv Tuesday, February 8, 2022, 12:52 PM Builders Associaton of Minnesota version 101014 Date Certificate Posted x Passive (No Fan) Active (With fan and monometer or other system monitoring Location (or future location) of Fan: Other Please Describe Here x 10/15 x x x 20 x 20 x 21 x 49 x x x x x Not applicable, all ducts located in conditioned space x Not required per mech. code Passive Powered Interlocked with exhaust device. Describe:Input in BTUS: 70,000 Capacity in Gallons: Other, describe: AFUE or HSPF% 93% Cfm's " round duct OR " metal duct Not required per mech. code x Passive Low: Other, describe: x Low: Location of fan(s), describe: Cfm's 4" " round duct OR Flex " metal duct ML193UH070 Heating Loss Manufacturer Lennox Natural Gas Output in Tons: 3 Ton50 Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Capacity continuous ventilation rate in cfms: 200CFM Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): 26,316Residential Load Calculation SEER /EER Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Electric Make-up Air Select a Type AO Smith Domestic Water Heater MECHANICAL SYSTEMS Rating or Size Efficiency 13 Seer Building envelope air tightness: Rim Joist (1st Floor) GPVL-50 13ACXN042-230 Model Heating System Natrual Gas Lennox Fiberglass, Batts Foundation Wall R-value Average U-Factor (excludes skylights and one door) U: Duct system air tightness: Cooling SystemTotal R-Value of all Types of InsulationType: Check All That Apply Mineral Fiberboard Insulation Location Foam, Closed Cell0.22 Describe other insulated areas Fiberglass, BlownTHERMAL ENVELOPE Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM Non or Not ApplicableAttic Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area Rim Joist (2nd Floor+) 0.30 Appliances Mech Room Heat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: 43,316 Heating Gain Cooling Load Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. Place your logo here New Construction Energy Code Compliance Certificate Name of Residential Contractor Stone Cottage Construction Inc. MN License Number Lakeville17936 Evershed Way BC636874 City Mailing Address of the Dwelling or Dwelling Unit Combustion Air Select a Type Location of duct or system: 31,690 Below Entire Slab Rigid, Extruded Polystyrene Ceiling, flat NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. New residential building permits WILL NOT be issued without this completed form. Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ Primary Contact: _________________________________________________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Description of Land Disturbing Activity: _____________________________________________________ NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___ If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an erosion and sediment control plan MUST be submitted with the residential building permit application. “The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.” (NPDES Construction Stormwater Permit, MPCA) “The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA) Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name of Person: ________________________________Company: _______________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: ________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots. No land disturbing activity may begin until a residential building permit has been issued. I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 3/4/22 Y AM