Loading...
HomeMy WebLinkAboutLA200424 - 18737 Javelin Ct Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: FIRST FLOORTOTAL4,861 SF1,546 SF-GARAGEBASEMENTFLOOR AREAFINISHED-1,313 SF1376 SF235 SFUNFINISHEDSECOND FLOOR (A & B)2,002 SFSIDEWALK146 SFGARAGE SLABBASEMENT SLABFLATWORK SQUARE FOOTAGE1,431 SF1,250 SFCOVERED PORCH-196 SF200 AMP SERVICEGARAGE RIGHTWALKOUTPRESERVE OF LAKEVILLELOT 6, BLOCK 218737 JAVELIN COURTNOTED OTHERWISE ON PLANS.ALL HEADERS ARE (2) 2x10 TYPICAL UNLESSWITH DIMENSIONS TO BE VERIFED SHALLTRUSS DESIGN BY MFG. TRUSSES NOTEDHEADERS:TRUSSES:BE FIELD MEASURED BY TRUSS SUPPLIERCURT & MELISSA LOCKMAN2x4 INTERIOR WALLS2x6 INTERIOR WALLSSHEATHING - INSULATEDCONCRETE WALLSBRICK / BRICK LEDGE2x6 EXTERIOR WALL WITH 1/2"FUTURE FINISHWALL LEGENDBRACED WALL REQUIREMENTS(FULL SHEET OF SHEATHING)LAKEVILLE, 550442018 BUILDING CODE2020 ENERGY CODEHEADER HEIGHT SCHEDULEABC6'-11-1/4"8'-0"7'-6"D6'-11-3/8"ALLOW FOR LARGER TRIM2nd. ADDITIONGAS FIREPLACE2'-1018"5'-838"17'-434"5'-838"1'-3"1'-3"3'-6"2'-1014"9'-118" 3'-21 4"6'-0"2'-1018"LINE OFLINE OFFIREPLACESHEETROCK4'-111 8"4'-2" 4'-2"2'-1014"1ST FLOOR FIREPLACE / ENT. CENTERSCALE: 1/4" = 1'-0"GreatRoomWOODSHEETROCK1'-5"NO HEARTHSTONE18'-5"2X6 WALL2X4 WALL6"2'-1014"2'-1014"18'-5"5'-1018"9"(2)24x24 FIXEDMULLEDB5'-1018"3'-412"(2) 2x10(2)24x24 FIXEDMULLEDB(2) 2x101'-5"5'-838"1'-3"3'-6"1'-3"5'-838"3'-414"8'-0"LINE OF MANTLESTANDARD BOX MANTLEEDGE TO EDGE ON SHEETROCKBUILT-INSBUILT-INSBUILT-INSBUILT-INSBUILT-INSMIN. TREAD 10"STAIR REQUIREMENTSMAX. RISE 7-3/4"10"734"MIN. NOSING 3/4"MAX. NOSING 1-1/4"1-1/4"SIDEWALK 146 SF4'-0"13'-6"26'-1012"CONCRETE4'-0"4'-0"GaragePorchTREX DECKING30x24FIXEDFRAMERS - MAKE SURE THERE IS ICE & WATER SHIELD BEHIND FRAMERS - 1/2" SHEATHING SHOULD BE FLUSH WITH CONCRETEPORCH & DECK LEDGERSYOUNFIELD SERIESEXTERIOR FOUNDATION INSULATION9'-0" TALL FOUNDATION WALLSSCALE: 1-1/2" = 1'-0"DUCT CHASE AT FLOOR TRUSS1A-11'-8" FLOOR TRUSS 3/4" SUB-FLOOR1-1/2" TOP CHORD8" x 8"DUCT1-1/2" SPRAY FOAM (R-10)1-1/2" BOTTOM CHORDFILL 20" FLOOR TRUSS WITHLOOSE FILL FIBERGLASS INSULATION9" = R-23 6" ROUND PIPET.O. RIM6x6 POST12" CONC. PIER2'-0"T.O. FTG.VARIES1'-714"T.O. WALL2 X 10 DROPPEDHEADER2x8 DECK JOIST1x6 LP TRIM1x LP TRIM1'-6"1'-6"ALUMINUM SOFFITCEDARMILL TEXTURELP PANEL WITH3/8" BEAD VULKEM CAULKINGALL 4 SIDES& BACK OF COLUMN1x3 LP TRIM ON FRONT1x2 ON EACH SIDE1'-2"34"ELEV. 108'-4"1'-0"SCALE: 1/2" = 1'-0"COLUMN #22 - WOOD PORCHTREXDECKING24" WIDE SOFFIT10" TALL10"8-14-20A-0COVER SHEETOAKHILL 4 BEDROOM TWO STORY GARAGE LEFT LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC627670 ORIGINAL DESIGN WORK BY: Dave.Zweber@DavidCharlezDesigns.com Tel: 952.428.8200 David C. Zweber David Charlez Designs/ PO132DECEMBER 23, 2021JANUARY 5, 2022JANUARY 17, 20224FEBRUARY 8, 20225MARCH 7, 2022Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode03/23/2022dmathews 18" RAKE AT GABLES ONTHE FRONT OF HOUSE9'-0" 9'-1018" 1'-218"9'-118"1'-634"8'-118" 10'-778" 4"1ST FLRSUBFLOORELEV.110'-2-1/8"T.O. MAINFND. WALLELEV.109'-0"2ND FLR.SUBFLOORELEV.121'-0"T.O. SLABELEV.100'-4"T.O. FTG.ELEV.100'16129:124.5:124:1210:1210:124:121'-0"1'-0"1'-6"1'-6"11'-0"11'-0"3'-9-5/8"THIS RIDGE HEIGHT SETS THE HEIGHT FORTHE MAIN 10:12 PITCH RIDGE LINE1'-0"1'-0"1'-0"1ST FLRSUBFLOORELEV.110'-2-1/8"9'-118"TOP OF PLATE6"1'-0"8" HARDIE TRIMFRIEZE7'-0"TREXPORCH& STEPSSCALE: 3/16" = 1'-0"FRONT ELEVATION - AA-11WALL PLATEELEV.129'-1-1/8"7'-0"T.O. FTG.ELEV.103'-8"13'-0"EL. 119'-3-1/4"TOP OF PLATEEL. 119'-3-1/4"HARDIE LAPHARDIE SHAKESBOARD - HARDIE COLOR PLUS PANELSBATTEN - HARDIE COLOR PLUSBATTEN MUST BE 3" W/ TEXTUREHARDIE SKIRT BD.DOWN 7" FROM SUB-FLOORFRAME WOOD PORCH(6" AFTER DECKING)1'-6"1'-6"10" SOFFIT.EACH SIDE1'-6" STONE RETURNHARDIE LAP7'-8"BL2606BL2606BL2606SHINGLES OVER 15# BUILDINGPAPER 15/32" OSB ROOF SHEATHINGICE DAM EAVES7'-1114" BOX OUTGABLE 6"16'-0"TEMPTEMPTEMP9'-0"10:12ADDRESSGARAGE DROPPED 16"FRONT WALL ONLY(2 RISERS)11'-0"9'-0"8-14-20FRONT ELEVATIONOAKHILL A-1ATWO STORY 4 BEDROOM LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC627670/ PO132DECEMBER 23, 2021JANUARY 5, 2022JANUARY 17, 20224FEBRUARY 8, 20225MARCH 7, 2022 41251210:124:1210:1210121012101210124124124'-6"6"1'-0"16:1216:12101216:124.5121012T.O. MAINFND. WALLELEV.109'-0"2ND FLR.SUBFLOORELEV.121'-0"1'-0"8'-118"T.O. SLABELEV.100'-4"6"1'-6"8'-118"TOP OF PLATE1'-6"1'-6"1'-6"1'-6"1ST FLRSUBFLOORELEV.110'-2-1/8"TOP OFPORCH BEAM9'-31 8"A-2REAR ELEVATION1SCALE: 1/8" = 1'-0"A-22SCALE: 1/8" = 1'-0"LEFT ELEVATIONSCALE: 1/8" = 1'-0"3RIGHT ELEVATIONA-2VENTGAS F.P.10:1210:121'-6"1'-6"ROOF VENTS OR RIDGE VENTS PER BUILDERS SPECIFICATIONS16:1216:1210:124:1210:124:124.5:124:124:125:1216:129:1210:121'-6"1'-6" 1'-8"1'-6"1'-0"1'-6" 1'-6"1'-0"1'-0"6"1'-6" 3'-6"SCALE: 1/8" = 1'-0"ROOF PLANA-241'-8"13 ROOF VENTSTOP OF FTGEL.96'-4"T.O. MAINFND. WALLELEV.109'-0"2ND FLR.SUBFLOORELEV.121'-0"T.O. SLABELEV.100'-4"1ST FLRSUBFLOORELEV.110'-2-1/8"TOP OF FTGEL.96'-4"T.O. SLABELEV.100'-4"10'-0"10'-0"TOP OF PLATEELEV.129'-1-1/8"ELEV. 129'-1-1/8"HARDIE ON ALL 4 SIDESHARDIE ON ALL 4 SIDESHARDIE ON ALL 4 SIDES1'-6 "9'-0"4122'-0"13'-8"9'-0"10:1210:12GARAGE DROPPED 16"FRONT WALL ONLY(2 RISERS)5:125:126X6 CEDAR POSTS1'-6"5:125:121'-6"1'-0"5:12512GLASS PANELGLASS PANELUNBALANCED FILL AREAUNBALANCED FILL AREAOAKHILL8-14-20ELEVATIONSA-2A4 BEDROOM TWO STORY LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC627670/PO132DECEMBER 23, 2021JANUARY 5, 2022JANUARY 17, 20224FEBRUARY 8, 20225MARCH 7, 2022 T.O. 8" CONC.T.O. FTG.EL. 100'-4"EL. 96'-4"6'-0"x 6'-11" PATIO(3) 1-3/4" x 9-1/2" LSL10'-0" MIN. FOOTING STEP NO DRAINTILE AT WALKOUT WALL ONLY10'-0" MIN. FOOTING STEP28"UP28"W.I.C.FinishedCARPET32"4'-4"FURN.WATERHEATERMechanical / StorageRoom4" CONC. SLABSUMP32"FLR.DRN.28"Fin.BathVINYL43 SF (FLR)FinishedHallCARPETFinishedLiving RoomCARPETFinishedBedroom # 5CARPET3 0 "FinishedFlex RoomRUBBER MAT8"x20" CONCRETEFOOTING - TYPICALUnexcavated4" CONC. SLABUnexcavated4" CONC. SLAB74'-0"12'-0"5'-0"5'-0"22'-0"16'-0"12'-0" 23'-0" 9'-0"17'-0"19'-0"7'-0" 1'-6" 54'-6" 1'-6"8'-0" 34'-0" 54'-6" 15'-7"18'-5" 4'-0"8'-0"5'-0" 17'-0"22'-0"2'-1012"6'-0"P.T. 2X4s@ 16" O.C. W/ 12" GYP.ON STAIR AREAFOUNDATION WALL8"LINE OF FRAMING ABOVE7'-4"T.O. 8" WALL 109'-0"T.O. 8" WALL 109'-0"T.O. FOOTINGEL. 100'-0"T.O. 8" WALL 100'-4"T.O. 8" WALL109'-0"BASEMENT PLANA-31SCALE: 1/4" = 1'-0"FLUSH BEAMSPER FLR. SYSTEMMFG. SPECIFICATIONST.O. 6"CURB 109'-0"T.O. 6"CURB 100'-4"4'-8"4'-8"2'-9"8'-7"Stairs9'-0" TALL FOUNDATIONS WALL3A-81A-61A-74A622'-0"4'-0"7'-10"21'-6"6'-2" 4'-9"235 SFFinishedLandingCARPET5,000 LB. FOOTINGSTRENGTH MIXBOTTOM OF GARAGEDOOR SHOULD BESET 4" DOWN FROMTOP OF POURED WALLVARIEST.O. SLABT.O. 8" WALLEL. 107'-0"4" DRAINTILE ATFOOTINGS ON EACHWALL AS MARKEDEL. 105'-0"T.O. FTG.EL. 109'-0"T.O. 6" CURB2" BRICK LEDGEEL. 107'-0"16'-3" M.O.2'-1012"EL. 103'-0"T.O. FTG.EL. 107'-8"T.O. 6" CURBGARAGESTART SLAB AT TOPOF WALL AT BACK OF2" BRICK LEDGEEL. 107'-0"2'-0"VOID9'-3" M.O. ALLOW FOR SEWER1'-412"24" VOID TO1'-412"T.O. FTG.EL. 96'-4"CDVARIEST.O. SLAB2" BRICK LEDGEEL. 108'-4"4'-0"(2) 36X60 MULLED(2) 2x10AA10'-1"13'-11"(2) 36X60 MULLED(2) 9-1/2" LSL42x60A7'-0"8'-0"4'-0"T.O. FOOTING96'-4"T.O. FOOTING100'-0"4'-2"9'-5"8'-01 2"(2) 9-1/2" LSL- DROPPED(2) 9-1/2" LSL(2) 2x10FIRE RESISTANT FLOOR SYSTEMOR 1/2" GYPSUM WALL BOARDWITH 80 SQ. FEET UNPROTECTED5'-0"22'-0"HOSEBIBHOSEBIBSHOULD BE THEPORCH FOOTINGSSAME HEIGHT AS THEHOUSE FOOTINGSIF SOIL IS UNDISTURBEDMAKE FOOTINGS 42" DEEP7'-0"2x8 PORCH LEDGERFTGS. TYP.24"x24"LINE OF PORCH ABOVE7'-8"12" CONC. PIERS1'-0"P.T. 2x8 DECK JOISTS @ 16" O.C.(2) 2x10FTGS. TYP.24"x24"12" CONC. PIERS(2) 2x101'-0"4'-10"19'-6"APPROXIMATE LINE OF SOFFITSS6'-11 4"T.O. 6"CURB 100'-4"16'-8"19'-2"(2) 1-3/4" x 9-1/2" LSL2-2x64-2x62-TRIMMERS(2) 2x105x5 PSL6x6 GLUEACH SIDE2-TRIMMERS3-TRIMMERS4-TRIMMERS5x5 PSLTO FND.3'-10"6'-134"SSSCDROD & SHELF 4'-101 4"3'-2"60x3418"LINEN2'-8" 11-7/8" TIMBERSTRAND LSL JOISTS MECH RM ONLY SEE EWP PLAN 11-7/8" TJI JOISTS SEE EWP PLAN 11-7/8" TJI JOISTS SEE EWP PLAN 11-7/8" TJI JOISTS2A-3HVACNO JOISTSHEREWROUGHT IRON SPINDLE2'-0"24'-0"48" VAN.SOUND INSULATE CEILINGSOUND INSULATE CEILINGC.T. WALLS1'-412"11'-3" M.O,1'-412"14'-0"2'-0"14'-0"30'-0" 2'-0"GARAGE DROPPED 16"FRONT WALL ONLY(2 RISERS)T.O. 8" WALLEL. 107'-0"T.O. 8" WALLEL. 107'-0"6X6 P.T.POSTSP.T. 2X10'S @ 16" O.C. (2)P.T. 2X10 RIM (3)P.T. 2X10 RIM13'-914"6'-914"6'-914"6'-914"234"14'-0"(2)P.T. 2X10 RIM 16" DIA. CONCRETE FILLED SONOTUBE FOOTINGS. FLARE BOTTOM16" OF FOOTING OUT TO 22" DIA.(2)P.T. 2X10 RIM P.T. 2X10'S @ 16" O.C.(3)P.T. 2X10 RIM(2)P.T. 2X10 RIM10'-334"5'-0"13'-9"EL. 109'-0"T.O. 6" CURBEL. 107'-8"T.O. 6" CURBEL. 107'-8"T.O. 6" CURBEL. 109'-0"T.O. 6" CURB0'-4" SLEEVE 2'-0" BELOW LEDGE(105'-0")2x6 EXTERIOR WALL WITH 1/2"WALL LEGEND2x4 INTERIOR WALLS2x6 INTERIOR WALLSSHEATHING - INSULATEDCONCRETE WALLSFUTURE FINISHMIN. TREAD 10"STAIR REQUIREMENTSMAX. RISE 7-3/4"10"734"MIN. NOSING 3/4"MAX. NOSING 1-1/4"1-1/4"FINISHED ROOM SIZESBEDROOM #5 & W.I.C.BATHSTAIRFLEX ROOMMECHANICALLIVING ROOMTOTAL248 SF75 SF103 SF230 SF235 SF457 SF1,548 SFFINISHED HALL47 SFFINISHED LANDING153 SFHEADER HEIGHT SCHEDULEABC6'-11-1/4"8'-0"7'-6"D6'-11-3/8"BASEMENT PLANA-38-14-20TWO STORY 4 BEDROOM OAKHILL LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC627670/ PO132DECEMBER 23, 2021JANUARY 5, 2022JANUARY 17, 20224FEBRUARY 8, 20225MARCH 7, 2022#1 Grade Southern Pine or(3)2x12 #2 Southern PineUFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel.(1)11-7/8 LSL GAS FIREPLACEBASEMENT FIREPLACESCALE: 1/4" = 1'-0"NO HEARTHUPFinishedLiving RoomCARPET9'-4"17'-8"42x60A7'-0"HOSEBIBAPPROXIMATE LINE OF SOFFIT(2) 1-3/4" x 9-1/2" LSL2-2x65'-814"5'-814"5'-814"SHEETROCK1'-434"3'-6"8'-8" 3'-21 4"3'-6"6'-312"5'-814"LINE OFLINE OFFIREPLACESHEETROCK4'-6"4'-2" 4'-2"1'-5"TILE6"1'-434"1'-434"1'-434"5'-814"5'-814"2'-5" 1'-5"LINE OF MANTLESTANDARD BOX MANTLEEDGE TO EDGE ON SHEETROCK2x6 EXTERIOR WALL WITH 1/2"WALL LEGEND2x4 INTERIOR WALLS2x6 INTERIOR WALLSSHEATHING - INSULATEDCONCRETE WALLSFUTURE FINISHSECTION @ MECH. ROOM2A-3SCALE: 1" = 1'-0"118" RIMLSL JOISTTJI JOIST2x6 WALLMECHANICAL ROOMFINISHED BASEMENT(TIMBERSTRAND)FINISHED BASEMENTS ONLYBASEMENT PLANA-38-14-20TWO STORY 4 BEDROOM OAKHILL LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC627670/ PODETAILS132DECEMBER 23, 2021JANUARY 5, 2022JANUARY 17, 20224FEBRUARY 8, 20225MARCH 7, 2022 START SLAB AT TOPOF WALL AT BACK OFOF WALL AT BACK OFGARAGEBOTTOM OF GARAGEDOOR SHOULD BESET 4" DOWN FROMTOP OF POURED WALL30x66 2- 2 x 6 2-2x62- 2 x 6 2- 2 x 6 6 X 6 G LU 32" MTL.GreatRoomWOOD28"28"DW20" FLOOR TRUSSES @ 19.2" O.C. 14' S.R.O.28"30"(2) 9-1/2" "LSL - CONT.(2)24x24 FIXED MULLED (2) 2x10UP 17RDN 16RLEDGE HVACDining RoomWOODKitchenWOODStudyRoomCARPETGarageFoyerWOODMudRoomVINYL66 SF (FLR)BathWOOD26 SF (FLR)PorchTREX DECKINGPantryWOODHallWOOD1'-6"12'-0"74'-0"12'-0"5'-0"22'-0"5'-0"16'-0"6'-0"4'-0"8'-0"34'-0" 7'-0" 17'-0" 12'-0"5'-0" 6'-2"4'-5"5'-0"22'-0"21'-6"7'-5" 11'-8"19'-0"17'-0"35'-8"FLOOR LINEABOVE4'-0"3'-8"4'-4"10'-7"9" 15'-7"18'-5" 6'-0"3'-0"3'-10"ClosetVINYL30 SF (FLR)1A-62- 2 x 6 8'-6"1A-73'-9"SCALE: 1/4" = 1'-0"FIRST FLOOR PLANA-41BEAM PER MFG. SPEC9"7'-0"7'-0"STAIRWELLFLUSH BEAMSPER FLR.SYSTEMMFG. SPECS.7'-5"4'-9"3'-512"7'-4"7'-8"1'-0"7'-0"16'x9' O.H. DOOR9'x9' O.H. DOOR (2) 11-7/8" LSL - CONT.WALL LINE ABOVEFLOOR SYSTEM DESIGNERTO DESIGN FLOOR TO CARRYWALL AND ROOF LOADSWALL LINE ABOVEFLOOR SYSTEM DESIGNERTO DESIGN FLOOR TO CARRYWALL AND ROOF LOADS20" FLOOR TRUSSES @ 19.2" O.C.(2) 11-7/8" LSL - FLUSH5'-0"8'-0"4'-0"9'-212"4'-5"(2) 2x10(2) 2x10 - CONT.(2) 9-1/2" LSL6'-812"3'-8"RO0F TRUSSES @ 24" O.C.2X6 WALL2X4 WALL4'-8" 4'-9"IRON RAILINGOPENABV.6'-10"1'-10"5'-6"20" FLOOR TRUSSES RO0F TRUSSES @ 24" O.C.13'-8"2'-6"6'-1014"4'-5"R & S R & S 20" FLOOR TRUSSES @ 19.2" O.C.1/2" SHEATHING - EXT.TYPICAL GARAGE WALL2x6 STUD WALLS @ 16" O.C. W/2x6 STUD WALLS @ 16" O.C. W/ (R-21)FIBERGLASS BATT INSULATION 4 MILPOLY VAPOR BARRIER & 1/2" GYP. BD.TYPICAL EXT. WALLINSIDE AND 1/2" SHEATHING - EXT.RO0F TRUSSES @ 24" O.C.4" CONCRETE SLAB PITCHEDTOWARDS OVERHEAD DOORS(2)24x24 FIXED MULLED 42"30x30FIXED30x30FIXED42x606'-0" X 8'-0" PATIO30x6654x66FIXED30x66Garage4" CONC. SLABBBBBAB(3) 2x102 PLY GIRDER ROOF OR TRUSS (2) 11-7/8" LSL(3) 16" LVL - FLUSH (3) 16" LVL - FLUSH (2) 2x10FLUSH28 "(2) 7-1/4" LSL(2) 7-1/4" LSL 2- 2 x 6 30x662- 2 x 630x6630x6630x66 B2-2x630x662-2x630x663'-4" REF.36" COOK TOPW/ WOOD HOOD5'-10"GAS FIREPLACE NO HEARTH 1'-5"3'-5"7'-0"6'-0"84"x 60"ISLANDTOP SIZE 96" x 72"4'-1"PANELACCESSATTIC22x301'-6"5'-0"6'-0"5'-0"16'-0"3'-0"1'-6" 9'-0" 1'-6"(3) 20" LVL7'-0" 7'-0"7'-6"DRYWALL OPENING4'-6"4'-3" HALF WALL30x30FIXED WINDOW SILLS MORE THAN 6" ABOVEFINISHED GRADE (SURFACE BELOW) ORLESS THAN 24" FROM FINISHED FLOORSHALL REQUIRE A WINDOW OPENINGCONTROL DEVICE.5'-2"2'-2"HallWOODSS8'-6"12'-658"1'-8"(1) 3-1/2" x5-1/2" LSLTALL WALLS @ STAIRSSTUDS: (1) 2X6 LSL @ 16" O.C.UPPER HEADER: (1) 3-1/2" x 7-1/4" LSLLOWER HEADER: (1) 3-1/2" x 5-1/2" LSLCOLUMNS: (3) 2x6 LSL(3) 2x6(3) 2x6(2) 7-1/4" LSL(2) 2x10(3) 11-7/8"LVL - DROPPED6X6 GLULAM6X6 GLULAM(2) 20" LVL FLUSH2-TRIMMERS(4) 2x6(2) 20" LVL FLUSH (2) 2x66X6 GLU(3)2x6( 3 ) 2 x 6(2) 2x10 - CONT.2-2x62-2x6(2) 2x102- 2 x 66X6 GLUTO FND.(4 ) 2 x 6(2) 2x1036" DRYWALL OPENING PED. ROD & SHELF 4'-134" PORTAL FRAMING (+96)LINE OF 20" SOFFIT(10" TALL)1'-8"36" DRYWALLOPENING(+96)SOFFITHVAC4' BI-FOLDBENCH BUILT-INSBUILT-INS 28" 4'-0" TRENCH DRAIN 4'-0" TRENCH DRAINDBL. WALL OVEN 4'-0" DROP ZONE11'x9' O.H. DOOR(2) 11-7/8" LSL1'-6"2'-0"11'-0"1'-6"30'-0"INSULATEGARAGECOMPLETEINSULATEGARAGECOMPLETE9'-0"SOUND INSULATE CEILING AND FLOOR14'-0"5/8" TYPE X GYP. BRD.ON ALL COMMON WALLS &CEILINGS.MUD ALL JOINTSRO0F TRUSSES@ 24" O.C.DeckTREX DECKING14'-0" x 14'-0"COVERED PORCHTREX DECKING2x10 JOISTS @ 16" O.C. 2x10 JOISTS @ 16" O.C.VAULT4:12VAULT4:127'-0"RO0F TRUSSES@ 24" O.C.(2) 11-7/8" LSL FULL LENGTH (2) 11-7/8 LSLFULL LENGTH(2) 11-7/8" LSLFULL LENGTH32" SERV.14'-0"GARAGE DROPPED 16"FRONT WALL ONLY(2 RISERS)GARAGECEILING HEIGHT@ 12'-11"2'-0"19'-0"10'-4"1'-0"13'-8"4'-0"4'-0" 4'-0"13'-4"6'-4"REC.CENTERGAS GARAGE HEATERCEILINGFANR.I.24" BEVERAGE FRIDGE4'-0" TRENCH DRAINAND FLUEMATCH HEIGHTAWALL LEGENDCONCRETE WALLSSHEATHING - INSULATED2x6 INTERIOR WALLS2x4 INTERIOR WALLS2x6 EXTERIOR WALL WITH 1/2"MIN. TREAD 10"STAIR REQUIREMENTSMAX. RISE 7-3/4"10"73 4"MIN. NOSING 3/4"MAX. NOSING 1-1/4"1-1/4"FINISHED ROOM SIZESSTUDY ROOM - CARPETMUD ROOM / W.I.C. - VINYLGREAT ROOM - CARPET133 SF120 SF316 SFPANTRY / HALL - WOOD59 SFKITCHEN/DINING/ENTRY/ HALL - WOOD885 SFBATH - WOOD42 SFSTAIRS - CARPET103 SFDHEADER HEIGHT SCHEDULEABC6'-11-1/4"8'-0"7'-6"6'-11-3/8"OAKHILL8-14-201ST FLOOR PLANA-44 BEDROOM TWO STORY LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC627670/ PO132DECEMBER 23, 2021JANUARY 5, 2022JANUARY 17, 20224FEBRUARY 8, 20225MARCH 7, 2022(2)9-1/2" LSLper EWP Plan2.6673.13.15.66.8PROVIDE DOUBLE LSL/LVLSTUDS FASTENED TOSIMPSON HTT5 HOLDOWNANCHOR AT LOCATIONSSHOWN w/ 12"Ø x 12" LONGSIMPSON TITEN HD SCREW-INANCHOR HOLDOWN ASSHOWN IN 4/S13.5555PFHPFHShear Panelw/holdownsShear Panelw/holdownsPFHPFH551155BWPsAbovePOST-INSTALLED HOLDOWN OPTION4S1FRAMING DETAILCONCRETEFOUNDATIONBELOWSIMPSON HTT5HOLDOWN ANCHOR ATLOCATIONS SHOWN w/12"Ø x 12" LONGSIMPSON TITEN HDSCREW-IN ANCHOR 1FOOTING PLAND-1SCALE: 3/16" = 1'-0"T.O. 8" WALL 108'-4"(2) 2x10(3) 2x10(3) 2x10(2) 2x10 (2) 2x10 (2) 2x10(2) 2x10(3) 2x106'-914"6'-914"10'-512"5'-0"13'-914"4'-0"6'-914"24" FLAIR AT BOTTOM6X6' POSTS12" SONO TUBEDIMENSIONS ARE TO CENTER OF FOOTINGS2x10 DECK JOISTS @ 16" O.C.2x10 DECK JOISTS @ 16" O.C.DECKPORCH DECKING SHOULD BEDOWN 4" FROM THE FIRST FLOOR(2) 2x10 STRINGERS9" O.C.SCALE:POST & PIER DETAIL3/4"=1'-0"2D-260" MIN.1'-0"6x6 DECK SUPPORTPOSTCONCRETE PIER FOOTINGMETAL ELEVATEDPOST SUPPORT5-1/212" SONOTUBEFLAIR AT BOTTOMT.O. DECKING3'-0"T.O. RAILINGALUM. CAP4x4 CEDAR POSTSBOLTALUM. RAILING6X6 POSTS(2) 2x10 BEAMSFLUSH AT CORNERTREX SKIRT BD.CEDAR RAILINGGLASS PANELSCALE: 1/4" = 1'-0"DECK FRAMING PLAN2D-12x10 JOISTS - SOUTHERN YELLOW PINE .40 TREATED5/4" TREX DECKING - #2 OR BETTER2-2x10 BEAMS SOUTHERN YELLOW PINE - .40 TREATED6x6 POSTS PONDEROSA PINE - .60 TREATED2X10 JOIST HANGERSBELOW FINISHED 1ST FLOORTOP OF DECK LEDGER SHOULD BE 4" DOUBLE RIM2x10 DECK JOISTS @ 16" O.C.COVERED DECK4:12 VAULT4:12 VAULTINTERIORINTERIOR(2) 1-3/4" x 11-7/8" LSL14'-0"Dining RoomWOOD7'-0"RO0F TRUSSES@ 24" O.C.6080SLIDER234"234"6'-914"6'-914"6'-914"BLOCKING FOR PICTURE FRAME DECKING2x10 JOISTS @ 16" O.C.14'-0" x 10'-4"DeckTREX DECKING19'-0"4'-0"6'-512"1'-0"12'-0"WESTBURY RAILING AT STAIRSALUM. RAILING AT DECK/PORCH(2) 1-3/4" x 11-7/8" LSL (2) 1-3/4" x 11-7/8" LSLOAKHILL8-14-201ST FLOOR PLANA-44 BEDROOM TWO STORY LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC627670/ PO132DECEMBER 23, 2021JANUARY 5, 2022JANUARY 17, 20224FEBRUARY 8, 20225MARCH 7, 2022#1 Grade Southern Pine or(3)2x12 #2 Southern Pine Jr. SuiteBathVINYL31 SF (FLR)60'-0"34'-0"30"28"30"28"28"30"32"28"30"30 "DN 17RR & S 2'-9"2'-9"2'-9"2'-9"MasterBedroomCARPET8" DEEP SOFFIT @ 8'-1-1/8" TALL (3) 2x10(2) 36X60 MULLEDPANELACCESSATTIC22x3015'-6"LaundryVINYL64 SFW.I.C.CARPETBedroom # 4CarpetBedroom # 2CarpetBedroom # 3CarpetHallCarpetLoftCarpetJack &Jill BathVINYL82 SFW.I.C.CarpetW.I.C.CarpetW.I.C.Carpet53'-0"12'-0"0"12'-0"34'-0"34'-0"7'-0"5'-0"12'-0"9'-0"14'-0"20'-0"12'-0"4'-0"4'-0" 16'-0" 12'-0"4'-0"5'-0"4'-0"60'-0"8'-11"4'-4"11'-0"22'-0"4'-11 14" HIGH WALL. 4'-11 14" HIGH WALL. 4'-6"HIGH GABLE END WALL18'-6"15'-6"SCALE: 1/4" = 1'-0"2nd FLOORA-513A61A51A64A6FANFANR & SR & S R & S36x60 R & S4'-3"4'-8" 15'-6" 6'-2"4'-8"4'-8"OPENTOBELOW(2)36x66 MULLED7'-0"7'-0"5'-534"3'-614"1'-1134"12'-5" 3'-1114"(2)36x60 MULLED5'-8"12'-10"AA(2)36x60 MULLED4'-4"15'-6"5'-334"16'-814"17'-6"A8'-7"8'-418"1'-1134"3'-4"48"VAN.11'-2"15'-6" 4'-0" 7'-614" 4'-0"6'-0"5'-8"9'-414"9'-334"3'-4"2'-4"5'-334"7'-514"3'-1012"3'-1134"5'-312"3'-1012"4'-014"RO0F TRUSSES @ 24" O.C. RO0F TRUSSES@ 24" O.C. RO0F TRUSSES @ 24" O.C.RO0F TRUSSES@ 24" O.C.WD(2) 30x54 MULLED30x30 TEMP11'-2"HEADER HEIGHT SCHEDULEBC6'-11-1/4"8'-0"7'-6"DAAAAA30x30 FIX TEMPAROOF GIRDER W/ 1-3/4 LEDGER LAGGED 10'-10"60x3428"6'-11-3/8"3'-10"6'-814"MasterBathLVT118 SF (FLR)(2) 24x48 TEMP.4'-10"5'-312"A(2) 2X103'-53 4"3'-8"28"60x348'-418"28"LINENFRAME 62-1/2" 60x34 TUB42" VANITY42" VANITY(1) 3-1/2" x7-1/4" LSLTALL WALLS @ STAIRSSTUDS: (1) 2X6 LSL @ 16" O.C.UPPER HEADER: (1) 3-1/2" x 7-1/4" LSLLOWER HEADER: (1) 3-1/2" x 5-1/2" LSLCOLUMNS: (3) 2x6 LSL(3) 2x6(3) 2x6FANEACH SIDE2-TRIMMERS(2) 2x10(3) 2x10(3) 2x10(2) 2x10ROOF GIRDER(3 ) 2 x 6(3) 2x6(2) 2X10 66"x36"FREE STANDINGTUB3'-1014"SSSSSSCDSCD3'-112"3'-4"(2) 2X1060" VANITY60" VANITY6'-5"28"28"(2) 24x14 NICHES STACKEDW/ DROP SINK32" BASE CABINETC.T. WALLS28" PKT. 28" PKT.C.T. WALLS28" PKT.151 SF222 SFBEDROOM # 4BEDROOM # 3JACK & JILL BATH - VINYLTHE TOTALS FOR FLOORING ARE ON FLOOR PLANFINISHED ROOM SIZESMASTER BEDROOMLAUNDRY - VINYLMASTER BATH - VINYL314 SF64 SFHALLWAY160 SFBEDROOM # 2211 SF193 SF110 SFMASTER W.I.C.82 SFJR. SUITE BATH - VINYL52 SFOAKHILL12-21-21SECOND FLOOR PLANA-54 BEDROOM TWO STORY LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC627670/ PO132DECEMBER 23, 2021JANUARY 5, 2022JANUARY 17, 20224FEBRUARY 8, 20225MARCH 7, 20223.663.66-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).Top of Wall Connections2.6655 COVEREDPORCHP.T. 6X6 POST412TOP OF MAIN LEVEL SUBFLOORTOP OF PORCH BEAMTYPICAL STAIR CONSTRUCTION NOTES:* 6'-10" MINIMUM HEADROOM* (3) 11-7/8" STAIR STRINGERS W/* 11" TREADS* PROVIDE 36"-36" HIGH HANRAILS & GUARD RAILS PER CODE.~ MINIMUM TREAD DEPTH 10" - MAX RISE 7-3/4"MINIMUM NOSING 34" MAX. NOSING 1-1/4"34'-0"6" 9'-118"1'-6"8'-0"9'-0" 12-5/16"7'-6"7'-3 3 8"2'-4 78" 9'-101 8" 2'-5 1 8"4'-10 1 4" 8'-11"SEAL ALL JOINTS, CRACKS, OR OTHEROPENINGS WITH POLYURETHANE CAULKFOR RADON PROTECTION4" CONCRETE SLAB11"11"10'-97 8" 8'-1 15 16"2'-5 15 16" 3'-1 11 16"5'-0 1 4"LINE OF RAKE END OVERHANGIN FRONT OF THIS SECTION20" FLOOR TRUSSES @ 19.2" O.C.11-7/8" LSL JOISTS @ 16" O.C.PRE-ENGINEERED ROOFTRUSSES PER MFG.R-49 INSULATION8'-91 2"1'-058"9'-11 8"1'-83 4"8'-11 8"GREATROOMFAMILYROOM1'-6"1'-6"412714"412714"101210125128'-918"1'-6"1'-8"MASTERBEDROOMSCALE: 1/4" = 1'-0"SECTIONA-51LOFT17'-0"17'-0"4'-5"1'-8"10"1'-2"HALF WALLHALF WALLMIN. TREAD 10"STAIR REQUIREMENTSMAX. RISE 7-3/4"10"73 4"MIN. NOSING 3/4"MAX. NOSING 1-1/4"1-1/4"OAKHILL12-21-21SECTIONA-64 BEDROOM TWO STORY LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC627670/ PO132DECEMBER 23, 2021JANUARY 5, 2022JANUARY 17, 20224FEBRUARY 8, 20225MARCH 7, 2022 BEDROOMROOF TRUSSESPER MFG.8'-111 8"1'-83 4" 8'-11 8"7'-0"7'-0"4'-11-1/4" 8'-111 8"2'-6"1'-6"GARAGE11'-0"11'-0"MAIN LEVEL SUBFLOOR1'-27 8" 1' - 2 "R-49 INSULATION16121612SCALE: 3/8" = 1'-0"SECTIONA-7120" FLOOR TRUSSEST.O. SLAB LEDGEEL. 109'-0"T.O. 6"CURB 107'-8"T.O. 6" CURB 109'-0"OAKHILL12-21-21SECTIONA-74 BEDROOM TWO STORY LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC627670/PO132DECEMBER 23, 2021JANUARY 5, 2022JANUARY 17, 20224FEBRUARY 8, 20225MARCH 7, 2022 2x6 STUD WALLS @16" O.C. W/ (R-21) FIBERGLASS BATTINSULATION, 4 MIL POLYVAPOR BARRIER & 1/2"GYPSUM BOARD INSIDE 2x6 STUD WALLS @16" O.C. W/ (R-21) FIBERGLASS BATTINSULATION, 4 MIL POLYVAPOR BARRIER & 1/2"GYPSUM BOARD INSIDE BOISE RIM BOARD (EXTERIOR)1-1/8" OSB RIM BOARD(R-20)8'-118"9'-0" WALLS - (1) 2x6 TOP PLATE 4" CONCRETE SLAB8" x 20" CONC. FTG'SPLATE W/ SILL SEAL INSUL.PRESSURE TREATED 2x6 SILL9'-0"ELEV. 100'-0"TOP OF FOOTINGELEV. 119'-3-1/4"ELEV. 121'-0"TOP OF PLATE2ND FLOORTOP OF 8" CONC.ELEV. 109'-0"ELEV. 110'-2-1/8"1ST FLOORMAINTAIN A MIN. CL.OF 6" FROM GRADETO BOTTOM OF SIDING9'-11 8"1178" 34" 34" 1'-8"ELEV. 129'-1-1/8"2ND FLOOR CLG.WATERPROOFING1) COAT EXTERIOR W/ POLYUREA WATER-3) SPRAY ABOVE GRADEW/ ANOTHER COAT OFPOLYUREA WATER-8" THICK CONC. WALLS20" FLOOR TRUSSESBLOCKING AT FOUNDATIONWALLS PARALLEL TO FRAMINGSEE DETAIL 3/A-7PROOFINGPROOFINGDUCTSPACEBLOCKBLOCKOR 1/2" SAG-RESISTANT5/8" TYPE "X" GYP. BD.R-49 ROOF INSULATIONPRE-ENGINEERED ROOFTRUSSES @ 24" O.C.OR 1/2" SAG-RESISTANT5/8" TYPE "X" GYP. BD.3/4" OSB FLOOR SHEATHING3/4" OSB FLOOR SHEATHINGMIN. 6" ENERGY HEALSEAL ALL JOINTS, CRACKS, OR OTHEROPENINGS WITH POLYURETHANE CAULKFOR RADON PROTECTION112"5,000 LB. FOOTINGSTRENGTH MIXRIGID METAL FLASHING INSTALLED BY SIDERPROTECTION TO6" BELOW GRADE1/2" ANCHOR BOLTS2) FOAM W/ POLYURETHANE (R-15)6 MIL POLY SLIP SHEET OVERFOAM PRIOR TO BACKFILLAS REQUIRED PER CITY3" EXTERIOR FOAM INSULATION ATLOOKOUT/WALKOUT SIDE WALLS. 2" FOAMAT FULL BASEMENT & 4' FROST FOOTINGS.GLUED AND NAILEDGLUED AND NAILEDBUILDING SECTION2A-7SCALE: 3/8" = 1'-0"@ 19.2" O.C.@ 6'-0" O.C. (8" EMBED.)SHINGLES OVER 15#15/32" OSB ROOF SHEATHINGBUILDING PAPER(ICE DAM EAVESFIRE RESISTANT FLOOR SYSTEMOR 1/2" GYPSUM WALL BOARD WITH80 SQUARE FEET UNPROTECTED11-7/8" TJI JOISTS(FINISHED BASEMENT)11-7/8" LSL JOISTS(UNFINISHED BASEMENT)1/2" SHEATHING FOREXTERIOR SHEATHINGTYPICAL UNLESS NOTEDOTHERWISE1/2" SHEATHING FOREXTERIOR SHEATHINGTYPICAL UNLESS NOTEDOTHERWISE7'-11"7'-10"7'-5"8'-014"SCALE: 1/4" = 1'-0"STAIR HEADROOMA-83SCALE: 1/4" = 1'-0"STAIR HEADROOMA-828'-014"7'-5"9'-3" OAKHILL8-14-20SECTION DETAILSA-84 BEDROOM TWO STORY LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC627670/PO132DECEMBER 23, 2021JANUARY 5, 2022JANUARY 17, 20224FEBRUARY 8, 20225MARCH 7, 2022 ©Project Number:Date:S11Sheets: of2Print Name:Signed: License Number:Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.Youngfield Homes, Inc.22260 Dodd BoulevardLakeville, MN 55044Lockman Residence18737 Javelin CourtLakeville, MN3407 Kilmer Lane NSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comDescriptionDateRevisionPLANS SHOWN LIGHT IN BACKGROUND ARE FORLOCATION REFERENCE ONLY. PLAN NOTES ANDELEMENTS SHOWN LIGHT MAY NOT NECESSARILYSUPPORT THE HANSON GROUP'S DESIGN.MAIN LEVEL HOUSE PLAN SHOWNFOR LOCATION REFERENCE ONLY2S1REFERENCE PLANUPPER LEVEL HOUSE PLAN SHOWNFOR LOCATION REFERENCE ONLY3S1REFERENCE PLANPOST-INSTALLED HOLDOWN OPTION4S1FRAMING DETAILCOPYRIGHT HANSON GROUP, LLC 2022THIS SHEET/S REPRESENTS A COMPLETE DESIGN OF THE "MAIN WINDFORCE RESISTING SYSTEM" FOR THE ENTIRERESIDENTIAL STRUCTURE. THE LOCATION AND LENGTH OF EACH BRACED WALL PANEL AND ENGINEERED WINDRESISTING ELEMENT THAT IS REQUIRED FOR THE HANSON GROUP'S DESIGN IS SHOWN ON THE STRUCTURALDRAWINGS. WALLS NOT SPECIFICALLY LABELED ON THE PLANS MAY BE STANDARD FRAMING.SECTIONS SHOWN DEPICT CONNECTIONS OF BRACED WALL PANELS TOROOF TRUSSES ABOVE, TO JOISTS/TRUSSES/BLOCKING ABOVE, AND TOJOISTS/TRUSSES/BLOCKING BELOW. THESE PANELS ARE NOT NECESSARILYREQUIRED TO ALIGN, BUT MAY DEPENDING ON PLAN LAYOUT.ROOFTRUSSESBRACEDWALL PANELFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)SIMPSONA35FRAMINGANGLEEACH END(4) 0.131"Øx 3" NAILSPROVIDE 12" WIDTH WEBSTIFFENER FOR ATTACHMENTOF FRAMING ANGLEBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONA35FRAMINGANGLEEACH ENDFLOORJOISTSPROVIDE 12" WIDTH WEBSTIFFENER FOR ATTACHMENTOF FRAMING ANGLEBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONA35FRAMINGANGLEEACH ENDFLOORJOISTSBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONLTP4FRAMINGPLATEEACH ENDFLOORTRUSSESFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)FLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)FLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)BRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONLTP4FRAMINGPLATEEACH ENDFLOORTRUSSESFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)BRACED WALL CONNECTIONBRACED WALL CONNECTIONBRACED WALL CONNECTION(ROOF TRUSSES)(FLOOR JOISTS)(FLOOR TRUSSES)DETAILS SHOWN ABOVE AREALTERNATIVE CONNECTIONS TO BEUSED WHEN BRACED WALL PANELDOES NOT ALIGN WITH FRAMING.EXTERIOR NON-BEARING WALLFRAME 2x4 BOXAROUND SPACEBETWEEN TRUSS w/SAME SHEATHINGAND FASTENING ASWALL BELOW(OR REPLACE w/ADEQUATE DEPTH2x MEMBER)#12 x 312" WOODSCREWS @ 16" O.C.INSTALLED INADDITION TO NAILS(MAIN/UPPERLEVEL ROOFTRUSS BEARINGWALLS ONLY)#12 x 312" WOODSCREWS @ 16" O.C.INSTALLED INADDITION TO NAILS(MAIN/UPPERLEVEL ROOFTRUSS BEARINGWALLS ONLY)EXTERIOR BEARING WALLREPRESENTSFIGURER602.10.8.2(3)INDICATES INTERIOR BRACED WALL PANEL w/ GYPSUMSHEATHING BOTH FACES WITH EITHER FASTENER OPTIONLISTED IN FRAMING NOTE 3, SPACED AT 4" O.C. PROVIDEINCREASED FASTENING REQUIREMENTS AS SHOWN BELOW.INDICATES ENGINEERED WIND RESISTING ELEMENTS TOBE CONSTRUCTED AS SHOWN IN THE DETAIL SHEETS.(MIN. LENGTH)INDICATES EXTERIOR BRACED WALL PANEL w/ SHEATHING ONEXTERIOR FACE IN ACCORDANCE w/ FRAMING NOTE 2. PROVIDEINCREASED FASTENING REQUIREMENTS AS SHOWN BELOW.(MIN. LENGTH)w/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESROOF TRUSSESFASTENED TO PLATESw/ (4) 0.131"Ø x 3"TOENAILS & SIMPSONH2.5 CLIPNAIL BOTTOM PLATETO RIM/JOIST/BLOCKING w/ (3) 16dNAILS EVERY 16"NAIL BOTTOM PLATETO RIBBON BRACE /TRUSS w/ (3) 16dNAILS EVERY 16"NAIL EACH JOIST TOTOP PLATES w/ (3)0.131"Ø x 3" NAILS2x4 BLOCKINGBETWEENTRUSSES NAILEDTO TOP PLATESw/ (3) 0.131"Ø x 3"NAILS EACHNAIL EACH TRUSS TOTOP PLATES w/ (3)0.131"Ø x 3" TOENAILSROOF TRUSSFASTENED TOPLATES w/0.131"Ø x 3"TOENAILS@ 6" O.C.NAIL BOTTOMPLATE TO RIM/JOIST/BLOCKINGw/ (3) 16d NAILSEVERY 16"NAIL RIM TOPPLATES w/0.131"Ø x 3"TOENAILS@ 6" O.C.NAIL BOTTOMPLATE TO LADDERTRUSS w/ (3) 16dNAILS EVERY 16"NAIL LADDERTRUSS TO TOPPLATES w/0.131"Ø x 3"NAILS @ 6" O.C.INTERIOR WALLPERPENDICULAR TO FRAMINGINTERIOR WALLPARALLEL w/ FRAMING2x4 BLOCKING BETWEENROOF TRUSSES NAILEDTO TOP PLATES w/ (3)0.131"Ø x 3" NAILS EACHNAIL BOTTOM PLATE TOBLOCKING w/ (3) 16dNAILS EVERY 16"PROVIDE FULL DEPTHBLOCKING BETWEEN JOISTSNAILED TO TOP PLATES w/(3) 0.131"Ø x 3" NAILS EACHNAIL EACH JOIST TO TOPPLATE w/ (3) 0.131"Ø x 3" NAILSNAIL BOTTOM PLATE TOBLOCKING w/ (3) 16dNAILS EVERY 16"PROVIDE FULL DEPTHBLOCKING BETWEEN TRUSSESNAILED TO TOP PLATES w/(3) 0.131"Ø x 3" NAILS EACHNAIL EACH TRUSS TO TOP PLATEw/ (3) 0.131"Ø x 3" TOENAILSPROVIDE ROOF TRUSSDIRECTLY IN LINE w/BRACED WALL PANELFASTENED TO PLATESw/ 0.131"Ø x 3"TOENAILS @ 6" O.C.NAIL BOTTOM PLATETO BLOCKING w/ (3)16d NAILS EVERY 16"PROVIDE JOIST DIRECTLYIN LINE w/ BRACED WALLPANEL FASTENED TOPLATES w/ 0.131"Ø x 3"TOENAILS @ 6" O.C.NAIL BOTTOM PLATETO BLOCKING w/ (3)16d NAILS EVERY 16"PROVIDE TRUSS DIRECTLYIN LINE w/ BRACED WALLPANEL FASTENED TOPLATES w/ 0.131"Ø x 3"TOENAILS @ 6" O.C.LOADSROOF SNOW LOAD: 35 PSFROOF DEAD LOAD: 15 PSFFLOOR LIVE LOAD: 40 PSFFLOOR DEAD LOAD: 15 PSFWIND LOAD:115 MPH ULTIMATE EXP. BCODE2020 MINNESOTA RESIDENTIAL CODESCOPEDESIGN AND DETAIL OF THE MAIN WINDFORCE RESISTING SYSTEM AND FOUNDATION WALLS AT A LOW-GRADE GARAGEFOR A SINGLE-FAMILY RESIDENCE. CONSTRUCTION IS TO BE IN ACCORDANCE WITH THIS DOCUMENT, STANDARDINDUSTRY PRACTICE, AND THE CODE.FRAMING NOTES1.THESE DOCUMENTS APPLY TO STRUCTURAL ONLY. REFER TO CONSTRUCTION DOCUMENTS FOR MORE INFORMATION.2.ALL EXTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O., WHICHMEETS OR EXCEEDS THE REQUIREMENTS OF CODE SECTION R602.10.4-WSP AND CS-WSP.A.2x4/2x6 STUDS SPACED BY SUPPLIER NOT TO EXCEED 16" O.C.B.EXTERIOR SHEATHING: 716" MIN. STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGESAND 12" O.C. AT INTERMEDIATE SUPPORTS OR 134" 16 GAUGE STAPLES @ 3" / 6" SPACING.3.ALL INTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O.A.2x4 OR 2x6 STUDS SPACED @ 16" O.C.B.WALL SHEATHING: 12" MIN. GYPSUM SHEATHING FASTENED TO FRAMING w/ 5d COOLER NAILS @ 8" O.C. MAX. ORTYPE S/W WALLBOARD SCREWS @ 16" O.C. MAX. (58" MINIMUM STUD PENETRATION)4.ALL FLOORS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA.A.FLOOR FRAMING SPACED AT A MAXIMUM OF 24" O.C.B.FLOOR SHEATHING: 34" STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGES AND 12"O.C. AT INTERMEDIATE SUPPORTS.5.ALL ROOFS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA.A.ROOF FRAMING SPACED AT A MAXIMUM OF 24" O.C.B.FASTEN ALL ROOF FRAMING TO TOP PLATES WITH SIMPSON H2.5 CLIP OR EQUIVALENT AND (4) 0.131"Ø x 3"TOENAILS.C.ROOF SHEATHING: 12" STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGES AND 12"O.C. AT INTERMEDIATE SUPPORTS OR 134" 16 GAUGE STAPLES @ 3" / 6" SPACING.6.ALONG LENGTH OF WALLS, LAP WALL TOP PLATES A MINIMUM OF 24" AND FASTEN TOGETHER WITH (12) 0.131"Ø x 3" INLAP ZONE. AT CORNERS AND INTERSECTIONS, LAP PLATES AND PROVIDE (3) 0.131"Ø x 3" FACE NAILS.7.CONNECTIONS NOT SPECIFICALLY NOTED ARE TO BE IN ACCORDANCE WITH CODE TABLE R602.3(1).8.TALL WOOD WALL FRAMING IS TO BE DESIGNED BY SUPPLIER FOR GRAVITY AND OUT-OF-PLANE WIND LOADS.9.THE ENTRY PORCH, DECK AND SCREEN PORCH ARE CONSIDERED TO BE PRIMARILY OPEN, NON-ESSENTIAL PORTIONSOF THE STRUCTURE AND ARE EXCLUDED FROM THE OVERALL MAIN WINDFORCE SYSTEM OF THE HOME. PROVIDECODE REQUIRED UPLIFT CONNECTIONS AT ALL POSTS AND TENSION CONNECTIONS AT LEDGERS.CONCRETEFOUNDATIONBELOWSIMPSON HTT5HOLDOWN ANCHOR ATLOCATIONS SHOWN w/12"Ø x 12" LONGSIMPSON TITEN HDSCREW-IN ANCHORJanuary 26, 20222.0252-18-22Garrett Brunell52600S1FRAMING DETAILGARAGE SHEARWALL5FASTEN FRAMING ABOVE AS SHOWNFOR BRACED WALL PANELS ALONGTHIS SHEARWALL AS WELL ASABOVE OVERHEAD DOORKING STUDS AND PSL POST BYSUPPLIERHATCHED AREA INDICATES 716" ORTHICKER PLYWOOD/OSB EXTERIORSHEATHING FASTENED TO STUDS w/8d NAILS @ 4" O.C. AT PANEL EDGES& @ 12" O.C. AT INTERIOR SUPPORTSSIMPSON STHD14 HOLDOWN ANCHORFASTENED TO DOUBLE STUDS/POST(REFER TO 4/S1 FOR POST-INSTALLEDHOLDOWN OPTION)(2) 12" Ø ANCHOR BOLTS(7" MIN. EMBED)TYPICAL 2x6 STUDS @ 16" O.C.PROVIDE DOUBLE STUDSAT END OF SHEARWALL(5-FT)PROVIDE TOP OF WALLCONNECTIONS SHOWN FORBRACED WALL PANELS ALONGINDICATED PORTION OF WALL(5-FT) BRACED WALL LINE BRACED WALL LINEBRACEDWALL LINE(4-FT)(4-FT)BRACEDWALL LINE(4-FT)(4-FT)(4-FT)(2.66-FT)(3.66-FT)(3.66-FT)BRACEDWALL LINE(4-FT)(4-FT)BRACEDWALL LINEBRACEDWALL LINE(3.1-FT)(4-FT)(5-FT)(6.8-FT) (5-FT)PROVIDE DOUBLE LSL/LVLSTUDS FASTENED TOSIMPSON HTT5 HOLDOWNANCHOR AT LOCATIONSSHOWN w/ 12"Ø x 12" LONGSIMPSON TITEN HD SCREW-INANCHOR HOLDOWN ASSHOWN IN 4/S1BRACED WALL LINE BRACED WALL LINE BRACED WALL LINE BRACED WALL LINE CONSTRUCTSHEARWALL ASSHOWN IN 5/S1CONSTRUCTSHEARWALL ASSHOWN IN 5/S1,MIRRORED(3.1-FT)BRACEDWALL LINE(4-FT)CONSTRUCTPORTAL FRAMEAS SHOWN IN 6/S1(5-FT) (7-FT) (5-FT) (4-FT)(5-FT)(4-FT)(4-FT)LOWER LEVEL HOUSE PLAN SHOWNFOR LOCATION REFERENCE ONLY1S1REFERENCE PLANBRACEDWALL LINE(4-FT)(4-FT)(4-FT)(4-FT)S1FRAMING DETAILGARAGE FRONT PORTAL FRAME6NOTEINFO APPLIES SYMMETRICALLY ACROSS DETAIL.1'-412"±9'-3"±11'-3"± @ SIM.11'-714"±FASTEN TOP PLATE TO HEADER w/ (2)ROWS 16d SINKER NAILS @ 3" O.C.(1) 2x6 BEARING STUD & (1) 2x6 FULLHEIGHT STUD EACH END OF HEADERLOCATE PANEL JOINT WITHIN 2'-0" FROM CENTEROF HEADER HEIGHT AS REQ'D (2x SOLIDBLOCKING REQUIRED AT SHEATHING JOINT)(2) 2x6 BEARING STUDS MIN.(VERIFY w/ SUPPLIER)PROVIDE 2x6 INFILL WALLABOVE HEADER AS REQ'DSIMPSON STHD14 EMBEDDED HOLDOWNANCHOR AT LOCATIONS SHOWN(REFER TO 4/S1 FOR ALTERNATIVE OPTION)FOUNDATION WALL BELOWLENGTH OF CONTINUOUS HEADER58" Ø ANCHOR BOLT (7" MIN. EMBED)w/ 2" x 2" x 316" PLATE WASHERNAIL SHEATHING TO HEADER w/ 8dNAILS @ 3" O.C. EA. WAY TYP.SMALL HATCH AREA INDICATES 716" ORTHICKER PLYWOOD OR OSB SHEATHINGAPPLIED TO EXTERIOR SIDE OF STUDS(NAIL SHEATHING AROUND PERIMETER w/ (2)ROWS 8d NAILS @ 3" O.C. STAGGERED & TOPLATES / BLOCKING @ 3" O.C.)SIMPSON MSTC40 STRAP ON INSIDE FACEOF WALL (PROVIDE SPACER TO FLUSHOUT HEADER TO WALL STUD THICKNESS)FASTEN KING STUD TO HEADER w/(2) ROWS 16d SINKER NAILS @ 3" O.C.LARGE HATCH AREA INDICATES 716" ORTHICKER PLYWOOD OR OSB SHEATHINGAPPLIED TO EXTERIOR SIDE OF STUDSw/ STANDARD 6"/12" NAILINGFASTEN FRAMING ABOVE ASSHOWN FOR BRACED WALL PANELSCONTINUOUS LVL HEADER TO SUPPORTVERTICAL LOADS BY SUPPLIER(MIN.312" WIDTH & MIN. 1178" DEPTH REQ'D)1'-412"±CONSTRUCTPORTAL FRAME ASSHOWN IN 6/S1, SIM.(2.66-FT)(5.6-FT)(3.5-FT)(4-FT)(5-FT) (11-FT) BRACED WALL LINE BRACEDWALL LINE(4-FT)(4-FT)(5-FT)(4-FT)Low Grade Garage Fdn.2-18-221MATERIALSCONCRETE FOOTINGS: F'c = 5,000 PSI @ 28 DAYS(OR 3,500 PSI WITH AN APPROVEDADMIXTURE THAT PROVIDES A WATERAND VAPOR RESISTANCE AT LEASTEQUIVALENT TO 5,000 PSI CONCRETE)CONCRETE WALLS: F'c = 3,500 PSI @ 28 DAYSREINFORCING STEEL: ASTM A615 GRADE 60AGGREGATE: FOOTINGS - 112" MAX WALLS/SLABS- 34" MAXON-SITE SOIL:SAND-CLAY (GROUP II ASSUMED):geq = 45 PSF/FT (ACTIVE)IF CLAY SOILS ARE ENCOUNTERED, BACKFILL WITH GRANULAR MATERIAL FULL HEIGHTBACKFILL SOIL:SAND (GROUP I) TO BE USED WHERE NOTED:geq = 30 PSF/FT (ACTIVE)ALLOWABLE SOILBEARING PRESSURE: 2,000 PSF - ASSUMEDWALL STUDS (10' OR LESS):SPF STUD GRADE OR BETTERWALL STUDS (OVER 10'):SPF NO.2 GRADE OR BETTERDIMENSIONAL LUMBER:SPF NO.2 GRADE OR BETTERTREATED LUMBER:SYP NO.2 GRADE OR BETTERLSL:134" WIDTH - 1.55E OR BETTERLVL:134" WIDTH - 1.9E OR BETTERFOUNDATION NOTES1.DRAIN TILE, DAMPPROOFING AND/OR WATERPROOFING, & INSULATION, AS WELL AS THEIR INSTALLATION, ARETO BE IN ACCORDANCE WITH THE CODE.2.INSTALL A MINIMUM OF (2) ANCHORS PER PORTION OF SILL PLATE AS WELL AS AN ANCHOR WITHIN 12" OFEACH END AS APPLICABLE.3.BAR SPLICES ARE TO BE LAPPED A MINIMUM OF 48 BAR DIAMETERS. PROVIDE 48" MATCHING HOOK BARS FORALL HORIZONTAL BARS AT WALL CORNERS AND INTERSECTIONS.4.CARE IS TO BE TAKEN DURING BACKFILLING TO MAINTAIN A PLUMB WALL ALIGNMENT.5.BULKHEAD STEP ALL RETAINING WALL TYPE FOOTING ELEVATION CHANGES. DO NOT JUMP FOOTINGS ATTHESE LOCATIONS.6.ADEQUATE SHORING IS THE RESPONSIBILITY OF THE CONTRACTOR.7.TOP OF GARAGE FOUNDATION WALLS ARE TO BE LATERALLY SUPPORTED PRIOR TO BACKFILLING. MEANSAND METHODS OF LATERAL SUPPORT ARE BY OTHERS. 2S2FRAME WALL ABOVE12"Ø ANCHOR BOLT(7" MIN EMBED) @ 72" O.C.MAX. OR EQUIVALENT STRAPS#4 x 2'-0" DOWELS @ 72" O.C.(5" MIN. EMBED) CENTERED IN WALL20" WIDE x 8" DEEP MIN.CONCRETE STRIP FOOTING(PROVIDE ADEQUATEFROST PROTECTION)8" MIN. C.I.P.CONCRETE WALL WALL SECTION GARAGE FOUNDATION WALLTO BE LOCATED IN THE FIELDAS REQUIRED AND ALLOWEDWITH SITE GRADE2" LEDGE#4 HORIZ. BARS @ 24" O.C.MAX. ABOVE GRADESLOPE GRADE AWAYFROM FOUNDATIONNOT TOEXCEED 2'-6"2'-0"#4 x 4'-0" HOOKS@ 24" O.C.2'-0"2"FRAME WALL ABOVE12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. WALL SECTION 3S2 GARAGE FOUNDATION WALLWITH LOW GRADE TO BELOCATED IN THE FIELD ASREQUIRED AND ALLOWED WITHSITE GRADE#4 x 4'-0" HOOKS@ 24" O.C.#4 HORIZ. BARS @ 24" O.C.VERT. BAR OPTIONS:#5 BARS @ 24" O.C. OR#6 BARS @ 36" O.C.8" MIN. C.I.P.CONCRETE WALLGARAGESLAB-ON-GRADESEE 1/S2PROVIDE GRANULAR MATERIALFOR FILL BELOW SLABSLOPE GRADE AWAYFROM FOUNDATIONCONTRACTOR IS TOPROVIDE TEMPORARY TOPOF WALL BRACING UNTILSLAB-ON-GRADE IS IN PLACE(HOOKS INTO SLAB PROVIDEREQUIRED TOP OF WALLLATERAL SUPPORT)NOT TO EXCEED 6'-0"5'-0" MIN.2"FRAME WALL ABOVE12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. WALL SECTION 4S2 GARAGE FOUNDATION WALLWITH LOW GRADE TO BELOCATED IN THE FIELD ASREQUIRED AND ALLOWED WITHSITE GRADE#4 HORIZ. BARS @ 24" O.C.VERT. BAR OPTIONS:#5 BARS @ 18" O.C. OR#6 BARS @ 24" O.C.10" MIN. C.I.P.CONCRETE WALLGARAGESLAB-ON-GRADESEE 1/S2PROVIDE GRANULAR MATERIALFOR FILL BELOW SLABSLOPE GRADE AWAYFROM FOUNDATIONCONTRACTOR IS TOPROVIDE TEMPORARY TOPOF WALL BRACING UNTILSLAB-ON-GRADE IS IN PLACE(HOOKS INTO SLAB PROVIDEREQUIRED TOP OF WALLLATERAL SUPPORT)NOT TO EXCEED 9'-0"5'-0" MIN.DESIGN SHOWN FOR 2/S2 - 4/S2 RELIES ON CURED CONCRETE SLABFOR TOP OF WALL LATERAL SUPPORT. MEANS AND METHODS OFBRACING DURING CONSTRUCTION IS THE RESPONSIBILITY OF THECONTRACTOR. THE HANSON GROUP RECOMMENDS EITHER STEELBRACING ALONG THE EXTERIOR PERIMETER OR POURED CONCRETEWING WALLS ALONG THE INTERIOR PERIMETER BY OTHERS.MAINTAIN MIN. 6" WIDESTEMWALL ABOVE LEDGEMAINTAIN MIN. 6" WIDESTEMWALL ABOVE LEDGE2'-0"2'-0"#4 x 4'-0" HOOKS@ 24" O.C.20" WIDE x 8" DEEP MIN.CONCRETE STRIP FOOTINGCENTERED UNDER WALL24" WIDE x 8" DEEP MIN.CONCRETE STRIP FOOTINGCENTERED UNDER WALL#4 x 2'-0" DOWELS @ 36" O.C.(5" MIN. EMBED) CENTERED IN WALL#4 x 2'-0" DOWELS @ 24" O.C.(5" MIN. EMBED) CENTERED IN WALL2'-0"2'-0"GARAGESLAB-ON-GRADESEE 1/S2PROVIDE GRANULAR MATERIALFOR FILL BELOW SLAB©Project Number:Date:S22Sheets: of2Print Name:Signed: License Number:Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.Youngfield Homes, Inc.22260 Dodd BoulevardLakeville, MN 55044Lockman Residence18737 Javelin CourtLakeville, MN3407 Kilmer Lane NSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comDescriptionDateRevisionPLANS SHOWN LIGHT IN BACKGROUND ARE FORLOCATION REFERENCE ONLY. PLAN NOTES ANDELEMENTS SHOWN LIGHT MAY NOT NECESSARILYSUPPORT THE HANSON GROUP'S DESIGN.COPYRIGHT HANSON GROUP, LLC 2022February 18, 20222.0252-18-22Garrett Brunell52600Low Grade Garage Fdn.2-18-221PARTIAL HOUSE FOUNDATION PLANSHOWN FOR LOCATION REFERENCEONLY1S2REFERENCE PLAN2S24 S2 3S24S22'-0"2'-0"THICKEN SLAB TO 5", REINFORCE w/ #3 BARS@ 24" O.C. EACH WAY & PROVIDE #4 x 4'-0"HOOKS SHOWN @ 24" O.C. IN FOUNDATIONWALLS AROUND PERIMETER OFREINFORCED SLAB SECTIONS NOTED ANDCAST INTO INDICATED PORTION OF SLAB Start Joist Layout Here. 16" o/c Framing Connector Summary PlotID Qty Manuf Product Face Nails Top Nails Member Nails Web Stiff H1 1 Simpson IUS1.81/11.88 10- 10dx1.5 - 2- 10dx1.5 No H2 2 Simpson IUS2.06/11.88 10- 10dx1.5 - 2- Strong-Grip No H3 1 User HUCQ1.81/11-SDS Not Required Products PlotID Length Product Plies Net Qty F34' 34' 0" 11 7/8" TJI 210 joist 1 5 F26' 26' 0" 11 7/8" TJI 210 joist 1 12 F20' 20' 0" 11 7/8" TJI 210 joist 1 11 F12' 12' 0" 11 7/8" TJI 210 joist 1 16 F8' 8' 0" 11 7/8" TJI 210 joist 1 2 TS1 12' 0" 1 1/2" x 11 7/8" 1.5E TimberStrand LSL 1 17 TS2 16' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 1 TS3 8' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 1 TS4 6' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 1 TS5 4' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 1 Rim 16' 0" 1 1/8" x 11 7/8" TJ Rim Board 1 14 Solid Blocking 2' 0" 5 1/2" x 11 7/8" CS Block 1 2 Wall Framing PlotID Length Product Plies Net Qty TSHd2-3 8' 0" 1 3/4" x 9 1/2" 1.55E TimberStrand LSL 3 3 TSHd1-2 8' 0" 1 3/4" x 9 1/2" 1.55E TimberStrand LSL 2 4 TSHd3-2 6' 0" 1 3/4" x 9 1/2" 1.55E TimberStrand LSL 2 2 TSHd4-2 4' 0" 1 3/4" x 9 1/2" 1.55E TimberStrand LSL 2 2 BBOHd1-2 8' 0" 2 x 10 SPF No.1/No.2 2 2 BBOHd2-2 4' 0" 2 x 10 SPF No.1/No.2 2 2 CSCS CSCS CS CSCS CSCS TS3TS4TS2TS5 RimRimRimRimRimRimRim Rim Rim Rim Rim Rim Rim Rim 1' 2" Round holes larger than 3-5/8" up to 7-1/4" max. in 1.5" x 11-7/8" 1.5E TimberStrand LSL joist only Edge of large holes need to be at least 4 times the diameter of the largest hole (for a 7-1/4" hole, the closest distance allowed to the next hole is 29", even if the next hole is a small 12" diameter hole). The hole must be centered within the joist vertically. No square or rectangular holes No more than (2) holes between 3-5/8" and 7-1/4" diameter allowed per span. See chart below for minimum distance from inside face of bearing to edge of hole for holes larger than 3-5/8" but not greater than 7.25" Minimum distance from edge of hole to inside face of bearing (end or intermediate) 4"5" *6.5" * 7.25" * 2'-0"2'-0" 3'-0"3'-6" * Allowable spans shown in TB-711 must be reduced by 9" with these size holes TSHd4-2 TSHd1-2 BBOHd2-2 TSHd3-2 BBOHd1-2 TSHd1-2 TSHd2-3 Rim H3 H1 1' 2"1' 6" Solid BlockingSolid Blocking F12' 16" O.C. F20' 16" O.C. F20' 16" O.C. F26' 16" O.C. F20' 16" O.C. F34' 16" O.C. TS1 16" O.C. H2 F8' 16" O.C. 2 Trimmers 6x6 Glulam6x6 Glulam LSL Joists in this area CAUTION: this layout is a mirror image of the original model. Please review all materials for accuracy to ensure bevel cuts, skewed hangers, and other angled output are reported correctly.Customer:Job Name:Address/Lot:Youngfield HomesLockman18737 Javelin CourtCity, State:Lakeville, MNPlan/Model #:Oakhill AJob Number:25323Lyman Lumber Company18900 West 78th StPO Box 130Chanhassen, MN(952) 470-4800Sheet: 1 of 3 A complete Javelin™ framing plan requires the Framer's Pocket Guide See the Framer's Pocket Guide for Product Trademark Information Drawn By:Jeff D.Drawn Date:2/3/22Revised By:Jeff D.Revision Date:2/25/22Revision #:3SALES PRESENTATION DRAWING:NO STRUCTURAL OR DIMENSIONAL CHECK HAS BEEN PERFORMED ON THIS DRAWING. LYMAN LUMBER COMPANY IS ONLY RESPONSIBLE FOR INDIVIDUAL MEMBER DESIGN,BASED UPON THE ASSUMED VERTICAL LOADS. BUILDER IS RESPONSIBLE FOROVERALL DESIGN OF THE STRUCTURE AND IT IS STRONGLY RECOMMENDEDTHAT ALL DRAWINGS AND CALCULATIONS BE REVIEWED BY THEENGINEER OF RECORD FOR THIS PARTICULAR PROJECT.Lack of proper bracing during construction can result in serious accidents. Observe the following guidelines: 1. All blocking, hangers, rim boards and rim joists at the end supports of the TJI® joists must be completely installed and properly nailed. 2. Laterial strength, like braced end wall or an existing deck, must be established at the ends of the bay. This can also be accomplished by a temporary or permanent deck (sheathing) fastened to the first 4 feet of joists at the end of the bay. 3. Safety bracing of 1x4 (minimum) must be nailed to a braced end wall or sheathed area (as in note 2) and to each joist. Without this bracing, buckling sideways or rollover is highly probable under light construction loads - such as a worker or one layer of unnailed sheathing. 5. Ends of cantilevers require safety bracing on both the top and bottom flanges. 6. The flanges must remain straight within 1/2" from true alignment. 4. Sheathing must be completely attached to each TJI® joist before additional loads can be placed on the system. WARNING NOTES: WARNING Joists are unstable until braced laterally Bracing Includes: Blocking Hangers Sheathing Rim Board Strut LinesRim Joist DO NOT stack building materials on unsheathed joists. Stack only over beams or walls. DO NOT walk on joists that are lying flat. DO NOT walk on joists until braced. INJURY MAY RESULT. Weyerhaeuser, iLevel®, Microllam®, Parallam®, Silent Floor®, TimberStrand®, TJI®, TJ® and Trus Joist® are registered trademarks of Weyerhaeuser NR. © 2012 Weyerhaeuser NR Company. All rights reserved. Header Spans: Up to 4'-11" = 1 Trimmer 5'-0" and Bigger = 2 Trimmers *** Unless Noted Otherwise *** Products PlotID Length Product Plies Net Qty M1-2 24' 0" 1 3/4" x 20" 2.0E Microllam LVL 2 2 M2-3 22' 0" 1 3/4" x 20" 2.0E Microllam LVL 3 3 M3-2 18' 0" 1 3/4" x 20" 2.0E Microllam LVL 2 2 M4-3 18' 0" 1 3/4" x 16" 2.0E Microllam LVL 3 6 TS1-2 16' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 4 TS2-2 14' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 4 TS3-2 12' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2 TS4-2 10' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2 TS5-2 8' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2 TS6-2 18' 0" 1 3/4" x 7 1/4" 1.55E TimberStrand LSL 2 2 BBO1-2 4' 0" 2 x 10 SPF No.1/No.2 2 2 Wall Framing PlotID Length Product Plies Net Qty TSHd1-3 14' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 3 3 TSHd2-2 12' 0" 1 3/4" x 9 1/2" 1.55E TimberStrand LSL 2 2 TSHd3-2 8' 0" 1 3/4" x 9 1/2" 1.55E TimberStrand LSL 2 2 TSHd4-2 4' 0" 1 3/4" x 9 1/2" 1.55E TimberStrand LSL 2 2 BBOHd1-2 12' 0" 2 x 10 SPF No.1/No.2 2 2 BBOHd2-2 6' 0" 2 x 10 SPF No.1/No.2 2 6 BBOHd4-3 4' 0" 2 x 10 SPF No.1/No.2 3 3 BBOHd3-2 4' 0" 2 x 10 SPF No.1/No.2 2 10 Framing Connector Summary PlotID Qty Manuf Product Face Nails Top Nails Member Nails Web Stiff H1 2 Simpson HHUS410 30- 10d - 10- 10d No H2 1 Simpson HUC28-2 14- 10d - 6- 10d No TS3-2 M4-3M4-3M1-2TS4-2 M3-2 H1 H1 BBO1-2 H2 BBOHd2-2 BBOHd2-2 TSHd4-2 TSHd3-2 BBOHd3-2 BBOHd4-3 TSHd2-2BBOHd2-2BBOHd1-2 BBOHd3-2BBOHd3-2 BBOHd3-2TS2-2M2-3 TS1-2 BBOHd3-2 TSHd1-3 TS6-2TS5-2TS2-2 TS1-22 Trimmers ← Floor Trusses →6x6 Glulam6x6 Glulam 6x6 Glulam6x6 Glulam 6x6 Glulam 4-2x6 3-2x63-2x6 4-2x6 CAUTION: this layout is a mirror image of the original model. Please review all materials for accuracy to ensure bevel cuts, skewed hangers, and other angled output are reported correctly.Customer:Job Name:Address/Lot:Youngfield HomesLockman18737 Javelin CourtCity, State:Lakeville, MNPlan/Model #:Oakhill AJob Number:25323Lyman Lumber Company18900 West 78th StPO Box 130Chanhassen, MN(952) 470-4800Sheet: 2 of 3 A complete Javelin™ framing plan requires the Framer's Pocket Guide See the Framer's Pocket Guide for Product Trademark Information Drawn By:Jeff D.Drawn Date:2/3/22Revised By:Jeff D.Revision Date:2/25/22Revision #:3SALES PRESENTATION DRAWING:NO STRUCTURAL OR DIMENSIONAL CHECK HAS BEEN PERFORMED ON THIS DRAWING. LYMAN LUMBER COMPANY IS ONLY RESPONSIBLE FOR INDIVIDUAL MEMBER DESIGN,BASED UPON THE ASSUMED VERTICAL LOADS. BUILDER IS RESPONSIBLE FOROVERALL DESIGN OF THE STRUCTURE AND IT IS STRONGLY RECOMMENDEDTHAT ALL DRAWINGS AND CALCULATIONS BE REVIEWED BY THEENGINEER OF RECORD FOR THIS PARTICULAR PROJECT.Lack of proper bracing during construction can result in serious accidents. Observe the following guidelines: 1. All blocking, hangers, rim boards and rim joists at the end supports of the TJI® joists must be completely installed and properly nailed. 2. Laterial strength, like braced end wall or an existing deck, must be established at the ends of the bay. This can also be accomplished by a temporary or permanent deck (sheathing) fastened to the first 4 feet of joists at the end of the bay. 3. Safety bracing of 1x4 (minimum) must be nailed to a braced end wall or sheathed area (as in note 2) and to each joist. Without this bracing, buckling sideways or rollover is highly probable under light construction loads - such as a worker or one layer of unnailed sheathing. 5. Ends of cantilevers require safety bracing on both the top and bottom flanges. 6. The flanges must remain straight within 1/2" from true alignment. 4. Sheathing must be completely attached to each TJI® joist before additional loads can be placed on the system. WARNING NOTES: WARNING Joists are unstable until braced laterally Bracing Includes: Blocking Hangers Sheathing Rim Board Strut LinesRim Joist DO NOT stack building materials on unsheathed joists. Stack only over beams or walls. DO NOT walk on joists that are lying flat. DO NOT walk on joists until braced. INJURY MAY RESULT. Weyerhaeuser, iLevel®, Microllam®, Parallam®, Silent Floor®, TimberStrand®, TJI®, TJ® and Trus Joist® are registered trademarks of Weyerhaeuser NR. © 2012 Weyerhaeuser NR Company. All rights reserved. Header Spans: Up to 4'-11" = 1 Trimmer 5'-0" and Bigger = 2 Trimmers *** Unless Noted Otherwise *** Wall Framing PlotID Length Product Plies Net Qty BBOHd2-3 8' 0" 2 x 10 SPF No.1/No.2 3 9 BBOHd1-2 8' 0" 2 x 10 SPF No.1/No.2 2 2 BBOHd3-2 6' 0" 2 x 10 SPF No.1/No.2 2 2 BBOHd4-2 4' 0" 2 x 10 SPF No.1/No.2 2 6 BBOHd4-2BBOHd4-2 BBOHd4-2 BBOHd2-3 BBOHd1-2 BBOHd2-3 BBOHd3-2 BBOHd2-3 Girder Truss CAUTION: this layout is a mirror image of the original model. Please review all materials for accuracy to ensure bevel cuts, skewed hangers, and other angled output are reported correctly.Customer:Job Name:Address/Lot:Youngfield HomesLockman18737 Javelin CourtCity, State:Lakeville, MNPlan/Model #:Oakhill AJob Number:25323Lyman Lumber Company18900 West 78th StPO Box 130Chanhassen, MN(952) 470-4800Sheet: 3 of 3 A complete Javelin™ framing plan requires the Framer's Pocket Guide See the Framer's Pocket Guide for Product Trademark Information Drawn By:Jeff D.Drawn Date:2/3/22Revised By:Jeff D.Revision Date:2/25/22Revision #:3SALES PRESENTATION DRAWING:NO STRUCTURAL OR DIMENSIONAL CHECK HAS BEEN PERFORMED ON THIS DRAWING. LYMAN LUMBER COMPANY IS ONLY RESPONSIBLE FOR INDIVIDUAL MEMBER DESIGN,BASED UPON THE ASSUMED VERTICAL LOADS. BUILDER IS RESPONSIBLE FOROVERALL DESIGN OF THE STRUCTURE AND IT IS STRONGLY RECOMMENDEDTHAT ALL DRAWINGS AND CALCULATIONS BE REVIEWED BY THEENGINEER OF RECORD FOR THIS PARTICULAR PROJECT.Lack of proper bracing during construction can result in serious accidents. Observe the following guidelines: 1. All blocking, hangers, rim boards and rim joists at the end supports of the TJI® joists must be completely installed and properly nailed. 2. Laterial strength, like braced end wall or an existing deck, must be established at the ends of the bay. This can also be accomplished by a temporary or permanent deck (sheathing) fastened to the first 4 feet of joists at the end of the bay. 3. Safety bracing of 1x4 (minimum) must be nailed to a braced end wall or sheathed area (as in note 2) and to each joist. Without this bracing, buckling sideways or rollover is highly probable under light construction loads - such as a worker or one layer of unnailed sheathing. 5. Ends of cantilevers require safety bracing on both the top and bottom flanges. 6. The flanges must remain straight within 1/2" from true alignment. 4. Sheathing must be completely attached to each TJI® joist before additional loads can be placed on the system. WARNING NOTES: WARNING Joists are unstable until braced laterally Bracing Includes: Blocking Hangers Sheathing Rim Board Strut LinesRim Joist DO NOT stack building materials on unsheathed joists. Stack only over beams or walls. DO NOT walk on joists that are lying flat. DO NOT walk on joists until braced. INJURY MAY RESULT. Weyerhaeuser, iLevel®, Microllam®, Parallam®, Silent Floor®, TimberStrand®, TJI®, TJ® and Trus Joist® are registered trademarks of Weyerhaeuser NR. © 2012 Weyerhaeuser NR Company. All rights reserved. Header Spans: Up to 4'-11" = 1 Trimmer 5'-0" and Bigger = 2 Trimmers *** Unless Noted Otherwise *** Print Name: Signed: Nick Hanson I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. License Number:1-1-21 46665Date: SCOPE OF DRAWINGS: THESE CAST-IN-PLACE CONCRETE FOUNDATION WALL GUIDELINE DRAWINGS ARE PREPARED AND CERTIFIED BY THE HANSON GROUP IN COMPLIANCE WITH THE MINNESOTA RESIDENTIAL CODE. THESE DRAWINGS CONTAIN STRUCTURAL INFORMATION FOR USE IN THE CONSTRUCTION OF STANDARD C.I.P. CONCRETE FOUNDATIONS FOR TYPICAL RESIDENTIAL CONDITIONS. THIS INFORMATION IS RELEVANT TO THE CONCRETE CONTRACTOR, THE GENERAL CONTRACTOR, AND THE FRAMING CONTRACTOR. THESE DRAWINGS EXPIRE ON DECEMBER 31, 2021. 2021 FOUNDATION GUIDE: DRAWING INDEX: SCOPE, INDEX, & CERTIFICATION S0 USE GUIDELINES AND MATERIALS S1 GENERAL NOTES S2 STEP FOOTING DETAIL S3 WALKOUT WALL DETAIL S4 LOOKOUT/KNEE WALL DETAIL S5 EXTERIOR LOW GRADE FOUNDATION DETAIL S6 BASEMENT WALL DETAIL S7 BASEMENT WALL VERTICAL REINFORCING TABLE S8 BRICK LEDGE DETAILS S9 FLOOR MEMBER BEARING DETAIL AND CONNECTION TABLE S10 BASEMENT WALL ANCHOR SPACING TABLE S11 NON-BEARING WALL JOIST BLOCKING DETAIL S12 NON-BEARING WALL TRUSS BLOCKING DETAIL S13 WINDOW WELL DETAIL S14 STEPPING DOWN WALL WITH GRADE DETAIL S15 COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 150 1.001 January 1, 2021 S0 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS SCOPE, INDEX, & CERTIFICATION Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane NorthSuite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 DRAWING USE GUIDELINES AND LIMITATIONS THE CONTRACTOR LISTED IN THE TITLE BLOCK BELOW IS LICENSED BY THE HANSON GROUP TO USE THIS PACKET WITHIN THESE LIMITATIONS NOTED FOR PROJECTS WHICH THE LICENSEE IS DIRECTLY RESPONSIBLE. THE LICENSEE MAY RELEASE THIS PACKET TO ITS SUB-CONTRACTORS AND CLIENTS FOR USE IN THE PROCUREMENT OF BUILDING PERMITS FOR PROJECTS WHICH THE LICENSEE IS USING THESE DRAWINGS. THE FOUNDATION GUIDELINES ARE TO BE ISSUED TO THE APPROPRIATE BUILDING DEPARTMENT IN ACCORDANCE WITH THEIR APPROVED PROCEDURE FOR USE BY THE BUILDING AGENCY DURING PLAN REVIEW AND INSPECTIONS. LIMITATIONS 1. BASEMENT FOUNDATION WALLS TEN FOOT OR LESS IN CLEAR HEIGHT (FROM TOP OF FLOOR SLAB TO TOP OF CONCRETE WALL AT SILL PLATE BEARING-NOT NECESSARILY BASEMENT CEILING HEIGHT). 2. STRUCTURE HEIGHT IS NOT TO EXCEED TWO STORIES ABOVE THE BASEMENT. 3. OVERALL BUILDING IS ASSUMED TO FALL WITHIN THE PRESCRIPTIVE LIMITATIONS OF THE CODE. A SITE SPECIFIC PLAN REVIEW HAS NOT BEEN PERFORMED. 4. STRUCTURES CONSTRUCTED OF WOOD FLOOR, WOOD ROOF, AND WOOD WALLS ONLY. NO PRECAST OR STRUCTURAL CONCRETE BEARING ON FOUNDATION WALLS IS PERMITTED. 5. EXTERIOR GRADE SLOPING DOWN AND AWAY FROM THE FOUNDATION WALLS. 6. ANY CASE BEYOND THE ABOVE NOTED ITEMS REQUIRES SEPARATE AND SPECIFIC STRUCTURAL ENGINEERING DOCUMENTS. COLD WEATHER GUIDELINES: 1. THE CONTRACTOR AND CONCRETE SUPPLIER ARE TO WORK TO OBTAIN A MIX DESIGN WHICH WILL ADEQUATELY PERFORM UNDER THE EXPECTED CONSTRUCTION CONDITIONS. THE USE OF ADDITIONAL CEMENT, HIGH-EARLY STRENGTH CONCRETE, AND/OR ACCELERATOR IS RECOMMENDED AT TEMPERATURES AND CONDITIONS EXPECTED LESS THAN TWENTY DEGREES F. 2. DELIVER CONCRETE WARM AND IN A TIMELY MANNER. PLACE CONCRETE EARLY IN THE DAY WHEN POSSIBLE. 3. DO NOT ADD ADDITIONAL WATER TO THE CONCRETE. THE USE OF WATER REDUCING AGENTS IS RECOMMENDED WHEN WORKABILITY CONCERNS EXIST. NO CONCRETE IS TO BE PLACED ON SNOW OR IN CONTACT WITH FROZEN MATERIALS. 4. REBAR DOES NOT NEED TO BE PRE-HEATED, BUT IS TO BE FREE OF FROST, SNOW, AND ICE. 5. BLANKETS OR OTHER ACCEPTED PROTECTION IS HIGHLY RECOMMENDED FOR THE TOP 24" OF THE WALLS WHEN THE AIR TEMPERATURE IS LESS THAN TEN DEGREES F AND FOR THE FULL HEIGHT OF THE WALL WHEN THE AIR TEMPERATURE IS LESS THAN ZERO DEGREES F. **THE ABOVE COLD WEATHER GUIDELINES ARE GENERAL RECOMMENDATIONS AND ALL ACI COLD WEATHER REQUIREMENTS ARE TO BE FOLLOWED AT THE RESPONSIBILITY OF THE LICENSEE. MATERIALS CONCRETE WALLS: F'c = 3000 PSI @ 28 DAYS MIX DESIGN AND PROPORTIONED BY CONCRETE SUPPLIER CONCRETE FOOTINGS: F'c = 5000 PSI @ 28 DAYS (OR 3000 PSI WITH AN APPROVED ADMIXTURE THAT PROVIDES A WATER AND VAPOR RESISTANCE AT LEAST OR EQUIVALENT TO 5000 PSI CONCRETE. AGGREGATE: FOOTINGS - 1 12" MAX. WALLS/SLABS - 34" MAX. REINFORCING STEEL: #4- BARS - ASTM A615 GRADE 40 #5+ BARS - ASTM A615 GRADE 60 TREATED SILL PLATE: SYP GRADE #2 OR BETTER ALLOWABLE SOIL BEARING PRESSURE 1,500 PSF MINIMUM EQUIVALENT REBAR TABLE FOR BUNDLED HORIZONTAL BARS (2)#4 = (1)#6 (3)#4 = (2)#5 (3)#5 = (2)#6 COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 151 1.001 January 1, 2021 S1 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS DRAWING LIMITATIONS & MATERIALS Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane NorthSuite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 GENERAL NOTES 1. DO NOT BACKFILL BASEMENT WALLS UNTIL THE CONCRETE HAS REACHED A MINIMUM COMPRESSIVE STRENGTH OF 2,250 PSI. IN ADDITION, DO NOT BACKFILL UNTIL THE BASEMENT WALLS ARE LATERALLY SUPPORTED BY THE FINAL INSTALLED FLOOR CONSTRUCTION AT THE TOP AND BOTTOM, UNLESS ADEQUATE SHORING IS INSTALLED AS REQUIRED. SHORING IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 2. STRIP FOOTING MAY BE PLACED AT ELEVATIONS LOWER THAN SHOWN IN THE DETAILS. 3. 1 12" DEEP BY 312" WIDE BY CONTINUOUS KEYWAYS MAY BE USED IN LIEU OF DOWELS FOR FULL HEIGHT ANDFROST WALLS. 4. STRIP FOOTING TO WALL CENTERLINES MAY BE OFFSET UP TO 2", HOWEVER, A MINIMUM OF 2" OF STRIP FOOTING IS TO EXTEND BEYOND THE WALL FACE ON EACH SIDE. 5. PROVIDE CODE REQUIRED FROST PROTECTION TO THE BOTTOM OF ALL FOOTINGS. 6. SLOPE GRADE DOWN AND AWAY FROM THE STRUCTURE A MINIMUM OF 6" WITHIN THE FIRST TEN FEET UNLESS ADEQUATE DRAINAGE OR SWALES ARE PROVIDED. 7. BOTH MATERIALS AND INSTALLATION OF DRAIN TILE, WATER-PROOFING, CONTROL JOINTS, FLASHING, AND INSULATION ARE TO BE IN ACCORDANCE WITH THE CODE BY THE GENERAL CONTRACTOR, UNLESS NOTED OTHERWISE. 8. ALL WALL WIDTHS SHOWN ARE NOMINAL DIMENSIONS, UNLESS NOTED OTHERWISE. OVERALL WALL THICKNESS MAY VARY BY UP TO 12" FROM THAT SHOWN ON THE DRAWINGS. 9. REINFORCING PLACEMENT TOLERANCE IS NOT TO EXCEED 12". BARS BEING SPLICED ARE TO BE WITHIN 2"OF CENTERLINE. MINIMUM SPLICE LENGTHS ARE 30 BAR DIAMETERS FOR GRADE 40 STEEL AND 48 BAR DIAMETERS FOR GRADE 60 STEEL. TYING IS NOT REQUIRED PROVIDED THESE TOLERANCES ARE MET. 10.PROVIDE MATCHING HOOK BARS FOR ALL HORIZONTAL BARS AT WALL CORNERS AND INTERSECTIONS. HORIZONTAL BARS MAY BE PLACED ANYWHERE WITHIN THE WALL AS LONG AS A 2" MINIMUM CLEAR COVER IS ACHIEVED ON ALL SIDES. 11.REINFORCING MAY BE BUNDLED UP TO A MAXIMUM OF THREE BARS. 12.DOWELS MAY BE DRILLED AND GROUTED IN PLACE. VERTICAL BARS AND DOWELS DO NOT NEED TO ALIGN. VERTICAL BARS MAY BE DRILLED AND EMBEDDED 5" INTO THE STRIP FOOTING IN LIEU OF DOWELS. 13.THE BOND BETWEEN CONCRETE AND REINFORCING WILL NOT BE APPRECIABLY REDUCED IF VERY MINOR FORM OIL IS PRESENT FOR THE CONDITIONS CONTAINED WITHIN THESE DRAWINGS. 14.SILL PLATES ARE TO BE ANCHORED WITH A MINIMUM OF TWO ANCHORS PER SILL SECTION. ALL SECTIONS ARE TO HAVE AN ANCHOR WITHIN 4" TO 12" OF EACH END. AN ANCHOR IS TO BE PLACED AT ALL WALL CORNERS AND INTERSECTIONS ON WALLS MORE THAN TWO FEET IN LENGTH. WALLS TWO FEET OR LESS IN LENGTH REQUIRE A MINIMUM OF ONE ANCHOR. REQUIREMENTS FOR SHEAR WALLS AND BRACED PANELS MAY BE IN EXCESS OF THESE REQUIREMENTS. TWO INCH WASHERS ARE ONLY REQUIRED AT FULL HEIGHT FOUNDATION WALLS. BUILDING DESIGNER IS TO ACCOMMODATE LOAD PATH FOR ANY VERTICAL LOAD TRANSFER OVER A SILL PLATE OVERHANG CONDITION. 15.ANCHOR BOLTS 12" DIAMETER OR LARGER ARE NOT REQUIRED TO BE CORROSION PROTECTED IN ACCORDANCE WITH CODE SECTION R317.3.1 EXCEPTION 1. 16.ALL PRE-MANUFACTURED FASTENERS AND CONNECTORS ARE TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS. 17.FLOOR BLOCKING IS ONLY REQUIRED AT FULL HEIGHT FIRST FLOOR NON-BEARING FOUNDATION WALLS. 18.CARE IS TO BE TAKEN DURING CONCRETE PLACEMENT TO MINIMIZE INADEQUATE HORIZONTAL AND DIAGONAL COLD JOINTS, AND TO PREVENT THESE JOINTS ENTIRELY IN WALLS WITHOUT VERTICAL REINFORCEMENT. ADEQUATELY VIBRATE CONCRETE AT POTENTIAL JOINT LOCATIONS AS REQUIRED, BASED ON PLACEMENT CONDITIONS TO ELIMINATE HONEYCOMBING AND TO ENSURE SUFFICIENT BONDING IS ACHIEVED. 19.TOP AND BOTTOM OF FOUNDATION WALLS ARE TO BE LATERALLY SUPPORTED PRIOR TO BACKFILLING. MEANS AND METHODS OF LATERAL SUPPORT ARE BY OTHERS. COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 152 1.001 January 1, 2021 S2 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS GENERAL NOTES Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 (2) #4 HORIZONTAL BARS BOTH TOP & BOTTOM EXTENDED AT LEAST 24" BEYOND EACH END OF STEP STABLE BANK HIGH FOOTING MAY BE EXTENDED PROVIDED BARS ARE PLACED AS SHOWN HORIZ. BARS TOP & BOTTOM 6" MIN THICK CONCRETE FOUNDATION, SEE OTHER DETAILS FOR MORE INFO OPTIONAL CONTROL JOINT AT EACH END OF STEP 72" MAX SPAN EQ.EQ.24" MINDETAIL B 3" MIN TYPCONCRETE STRIP FOOTING 11B DETAIL A 36" MIN STEP 2 x STEP STEPNOTE: DO NOT LOCATE CONCENTRATED LOADS IN EXCESS OF 2,000 PLF OR 10,000 POUNDS ABOVE STEP LOCATIONS SHOWN REAR FROST WALL LOOKOUT WALL FULL HEIGHT WALL GARAGE FROST WALL ELEVATION SHOWN FOR REPRESENTATION PURPOSES ONLY -MAY NOT APPLYELEVATION STEP SPACING REQUIREMENTS A TYP. COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 153 1.001 January 1, 2021 S3 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS STEP FOOTING DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6" MIN. WOOD FRAMING ABOVE BY OTHERS 12"Ø x 10" LONG ANCHOR BOLTS (7" MIN. EMBED) @ 72" O.C. MAX. OR EQUIVALENT METAL STRAP ANCHORS SLOPE GRADE AWAY FROM FOUNDATION OPTIONAL STEM WALL MINIMUM THICKNESS TO MATCH SILL PLATE SILL PLATE TO MATCH FRAME WALL ABOVE 16" MAX FOR 4" THICK STEM 24" MAX. FOR 6" THICK STEM SLAB-ON-GRADE BY OTHERS (1) #4 x CONTINUOUS HORIZONTAL BAR AT TOP OF WALL 6" MIN. C.I.P. CONCRETE FOUNDATION WALL UNREINFORCED CONCRETE STRIP FOOTING SEE S7 #4x2'-0" DOWELS @ 72" O.C. MAX (5" MIN. EMBED) DOWELS ARE NOT REQUIRED IF BACKFILL IS PLACED EQUALLY ON BOTH SIDES IN LIFTS NOT TO EXCEED 24"-ALTERNATE EACH SIDE COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 154 1.001 January 1, 2021 S4 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS WALKOUT WALL DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6" MIN.3'-0" MAX GRADE HEIGHTABOVE TOP OF SLAB#4 x 2'-0" DOWELS (5" MIN. EMBED) CENTERED IN WALL @ 48" O.C. (SAND SOIL) OR 36" O.C. (SANDY-CLAY SOIL) OR 24" O.C. (CLAY SOIL) DOWELS MUST BE WET SET OR DRILLED AND EPOXY GROUTED 6" MIN. THICK C.I.P. CONCRETE FOUNDATION WALL SLOPE GRADE AWAY FROM FOUNDATION 12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED) @ 72" O.C. MAX. OR EQUIVALENT METAL STRAP ANCHORS (1) #4 x CONT HORIZONTAL BAR AT TOP OF WALL FRAMING & SILL PLATE BY OTHERS SLAB-ON-GRADE BY OTHERS UNREINFORCED CONCRETE STRIP FOOTING SEE S7 (18" MIN WIDTH FOR CLAY BACKFILL OR 16" MIN WIDTH IF 2'-6" MAX UNBALANCED BACKFILL) COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 155 1.001 January 1, 2021 S5 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS LOOKOUT/KNEE WALL DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6'-0" MAXWOOD FRAMING ABOVE BY OTHERS 12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED) @ 72" O.C. MAX. OR EQUIVALENT METAL STRAP ANCHORS SLOPE GRADE AWAY FROM FOUNDATION AT A GRADUAL 2% SLOPE PER GENERAL NOTE 6 SILL PLATE TO MATCH FRAME WALL ABOVE #4 x CONTINUOUS HORIZONTAL BARS @ 24" O.C. TYP. OPTIONAL 2" RIGID INSULATION ON INSIDE FACE AND UNDER SLAB-ON-GRADE FOR 24" MIN. UNREINFORCED CONCRETE STRIP FOOTING SEE S7 (DROP FOR FROST AS REQUIRED PER SITE DESIGN) #4x2'-0" DOWELS @ 48" O.C. MAX (5" MIN. EMBED) (1) #4 x CONTINUOUS HORIZONTAL BAR AT TOP OF WALL OPTIONAL SLAB LEDGE CONCRETE SLAB-ON-GRADE 8" MIN. C.I.P. CONCRETE FOUNDATION WALL #4x4'-0" HOOKS @ 24" O.C. BENT OR DRILLED AND EPOXY GROUTED 3'-0"1'-0"NO HOOKS @ 3'-0" OR LESSGRANULAR MATERIAL (SAND) DETAIL ABOVE MAY ONLY BE UTILIZED FOR A LENGTH OF 15'-0" #5 VERTICAL BARS @ 24" O.C. CENTERED IN WALL TO AID IN THE REDUCTION OF CRACKING AND BACKFILLING ISSUES PRIOR TO TOP OF WALL PINNING CONTRACTOR IS TO PROVIDE TEMPORARY TOP OF WALL BRACING UNTIL GARAGE SLAB-ON-GRADE IS IN PLACE (HOOKS INTO GARAGE SLAB PROVIDE REQUIRED TOP OF WALL LATERAL SUPPORT) COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 156 1.001 January 1, 2021 S6 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS UNBALANCED FOUNDATION DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6" MIN. CLEAR HEIGHTBACKFILL HEIGHT112" CLEAR UNREINFORCED CONCRETE STRIP FOOTING PER CODE OR BY BUILDING DESIGNER, AS AN ALTERNATIVE GUIDE USE TABLE SHOWN BELOW 8" MIN. C.I.P. CONCRETE FOUNDATION WALL-SEE REBAR TABLE S8 FOR VERTICAL REBAR ANCHOR BOLTS SEE WALL ANCHOR INFO ON S11 FLOOR TO SILL CONNECTION SEE S10 WOOD FLOOR SYSTEM BY OTHERS SLOPE GRADE AWAY FROM FOUNDATION 2x6 MIN SILL PLATE CLEAR HEIGHT OF 8'-0" OR LESS (2)#4xCONT. HORIZONTAL BARS CLEAR HEIGHT OF 8'-0" OR MORE (3)#4xCONT. HORIZONTAL BARS CONCRETE SLAB-ON-GRADE PLACED TIGHT TO FOUNDATION WALL #4x2'-0" DOWELS @ 72" O.C. MAX (5" MIN. EMBED) GENERAL STRIP FOOTING SIZE GUIDE SOIL ONE-STORY STRUCTURE TWO-STORY STRUCTURE 2000 PSF 16" WIDE x 8" THICK 20" WIDE x 8" THICK 1500 PSF 20" WIDE x 8" THICK 26" WIDE x 8" THICK THIS TABLE IS A GENERAL FOOTING SIZE GUIDE FOR TRIBUTARY UNIFORM LOADING ONLY BASED ON MAXIMUM 25'-0" FLOOR SPANS & 50'-0" ROOF SPANS AND IS TO BE VERIFIED BY HOME DESIGNER. FURTHER CONSIDERATION IS TO BE TAKEN BY HOME DESIGNER FOR VENEER WEIGHT, WALL THICKNESSES OVER 10", AND FLOOR AND ROOF DEAD LOADS OVER 15 PSF. CONCENTRATED LOADS FROM GIRDER TRUSSES, BEAMS, HEADERS, ETC. ARE TO BE ACCOUNTED FOR AND SIZED INDEPENDENTLY OF THIS GUIDE BY OTHERS. COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 157 1.001 January 1, 2021 S7 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS BASEMENT WALL DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 GRADE 60 #6 VERTICAL BAR SPACING FOR FULL HEIGHT WALLS w/ F'c = 3000 PSIALTERNATIVE TO CODE TABLE R404.1.2EQUIVALENT VERTICAL REBARSUBSTITUTION TABLEBACKFILL TYPECLEAR HEIGHT(SEE S7)BACKFILL HEIGHT(SEE S7)8'-0"9'-0"10'-0"7'-6"7'-0" OR LESS8'-6"8'-0"7'-0"6'-0" OR LESS9'-6"9'-0"8'-0"7'-0"6'-0" OR LESS8"10" 12"8"10" 12"8"10" 12"NONE NONE NONENONE NONENONE NONENONE NONENONENONENONENONENONENONENONENONE NONENONE NONENONENONENONENONENONENONENONENONENONENONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONE* = NONE IF F'c = 4,000 PSI*36"*36"*36"*36"*36"*36"36"36"36"36"36"36"36"36"24"24" 24"24"SAND (30 PSF/FT)WALL THICKNESSSANDY CLAY (45 PSF/FT)WALL THICKNESSCLAY (60 PSF/FT)WALL THICKNESS#6 @ 24" = #5 @ 18" = #4 @ 12" (GRADE 60) = #4 @ 8" (GRADE 40)(1)#6 = (2)#4 (GRADE 60)#6 @ 36" = #5 @ 24" = #4 @ 18" (GRADE 60) = #4 @ 12" (GRADE 40) COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 158 1.001 January 1, 2021 S8 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS VERTICAL REINFORCING TABLE Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 VENEER OR SLAB-ON-GRADE BY OTHERS FOUNDATION WALL SEE S7 WOOD FLOOR SYSTEM BY OTHERS FRAMING BY OTHERS 16" HIGH MAX x 6" THICK MIN STEM6"MINWOOD FLOOR SYSTEM BY OTHERS FRAMING BY OTHERS 6" MIN THICK STEM #4 DOWELS @ 36" O.C. EMBEDDED 24" INTO LOWER WALL FOUNDATION WALL SEE S7 VENEER OR SLAB-ON-GRADE BY OTHERS 12"VENEER OR SLAB-ON-GRADE BY OTHERS FOUNDATION WALL SEE S4 OR S5 FRAMING BY OTHERS 16" HIGH MAX x 4" THICK MIN STEM THICKNESS TO MATCH SILL PLATE6"3'-0" MAXVENEER OR SLAB-ON-GRADE BY OTHERS FOUNDATION WALL SEE S6 SLAB-ON-GRADE FRAMING BY OTHERS 6" MIN THICK STEM DETAIL @ HIGH GRADE SIM @ NON-BEARING DETAIL @ LOOKOUT SIM @ FROST WALL DETAIL @ FROST WALLS w/ LOW GRADE DETAIL @ LOW GRADE SIM @ NON-BEARING 112" CLEAR MINMAX#4 DOWELS @ 36" O.C. EMBEDDED 24" INTO LOWER WALL (CENTER IN STEMWALL) SLOPE GRADE AWAY FROM FOUNDATION SLOPE GRADE AWAY FROM FOUNDATION SLOPE GRADE AWAY FROM FOUNDATION SLOPE GRADE AWAY FROM FOUNDATION NOTE: INCREASE STRIP FOOTING WIDTH AT ALL WALLS SUPPORTING MORE THAN 6'-0" OF VENEER. WIDTH TO INCREASE BY THICKNESS OF VENEER MULTIPLIED BY NUMBER OF STORIES. COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 159 1.001 January 1, 2021 S9 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS BRICK LEDGE DETAILS Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6"12"Ø ANCHOR BOLTS w/ NUT & 18" THICK x 2"Ø OR SQUARE WASHER SEE S11 FOR SPACING (7" EMBED MIN) -METAL STRAP ANCHORS TO BE INSTALLED AT MANUFACTURER EQUIVALENT SPACING FLOOR SYSTEM, TYPE, SIZE, AND SPACING TO BE DETERMINED BY OTHERS RIM BOARD OR BRACING MATERIAL BY OTHERS 2x6 SILL PLATE MINIMUM FLOOR TO SILL CONNECTION AT EACH MEMBER SEE TABLE BELOW WASHER TO BE COUNTERSUNK FLUSH w/ TOP OF SILL PLATE SEE FULL HEIGHT WALL SECTION ON S7 FOR FOUNDATION WALL REQUIREMENTS SLOPE GRADE AWAY FROM FOUNDATION MINTRUSS/JOIST CONNECTION FOR FULL HEIGHT WALLS**** BACKFILL TYPECLEAR HEIGHT (SEE S7) FLOOR MEMBER SPACING 8'-0" 9'-0" 10'-0" 16" 19.2" A (4) 0.131"Ø x 3" TOP NAILS AT EACH MEMBER SAND (30 PSF/FT) SANDY CLAY (45 PSF/FT) CLAY (60 PSF/FT) 24" 16" 19.2" 24" 16" 19.2" 24" A A A A A A A B A A B B B B B C C C D D D D D D D C CONNECTION A (4) 0.148"Ø x 3" TOP NAILS AT EACH MEMBERCONNECTION B (2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON A35/USP MPA1 OR USP LJC AT EACH MEMBER CONNECTION C CONNECTION D (2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON FWANZ* OR USP LJQ** OR (2) SIMPSON A35s***/(2) USP MPA1s*** AT EACH MEMBER * FWANZ TO BE USED WITH A MIN. 118" OSB RIM AND LOCATED w/IN 5" OF EACH MEMBER. WITH FLOOR TRUSSES, FWANZ MUST BE IN CONTACT WITH A TRUSS OR A MINIMUM 2x4 CONTINUOUS BOTTOM BRACE MUST BE IN PLACE. ** LJQ IS TO BE APPROPRIATELY SIZED BASED ON MEMBER WIDTH. *** MEMBER MUST BE A MINIMUM OF 3" WIDE FOR PLACEMENT OF (2) SIMPSON A35s/(2) USP MPA1s. ****CONNECTIONS ARE CLASSIFIED A TO D, WITH D BEING THE STRONGEST. IT IS ACCEPTABLE TO USE A STRONGER CLASS CONNECTION THAN NOTED IN THE TABLE ABOVE. 2x8 SILL PLATE TO BE USED w/ MAXIMUM OF 112" OVERHANG (MAINTAIN 234" EDGE DISTANCE TO BOTH CONCRETE AND INSIDE OF SILL PLATE) - VERTICAL LOAD TRANSFER BY SUPPLIER COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 1510 1.001 January 1, 2021 S10 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS FLOOR BEARING CONNECTIONS Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 12"Ø ANCHOR BOLT AND NON-BEARING WALL BLOCKING SPACING FOR FULL HEIGHT WALLS* ALTERNATIVE TO CODE TABLE R404.1.(1) BACKFILL TYPE CLEAR HEIGHT (SEE S7) BACKFILL HEIGHT (SEE S7) 8'-0" 9'-0" 10'-0" 7'-6" 7'-0" 8'-6" 8'-0" 7'-0" OR LESS 9'-6" 9'-0" 8'-0" 7'-0" OR LESS 72" * 12"Ø EPOXIED THREADED ROD w/ 6" EMBED MAY BE USED AT SPACING SHOWN SAND (30 PSF/FT)SANDY CLAY (45 PSF/FT) CLAY (60 PSF/FT) 6'-0" OR LESS 72" 72" 72" 72" 72" 72" 72" 72" 72" 72" 72" 72" 48" 60" 72" 48" 60" 72" 36" 48" 72" 36" 36" 72" 72"72" 48" 24" 24" ALTERNATIVE ANCHOR SPACING FOR FULL HEIGHT WALLS** ALTERNATIVE TO CODE TABLE R404.1.(1) BACKFILL TYPECLEAR HEIGHT (SEE S7) BACKFILL HEIGHT (SEE S7) 8'-0" 9'-0" 10'-0" 7'-6" 7'-0" 8'-6" 8'-0" 7'-0" OR LESS 9'-6" 9'-0" 8'-0" 7'-0" OR LESS 48" ** APPLIES TO MAB 15/FA1, MAB23/FA2, MAS/FA3, 12"Ø EXPANSION BOLT w/ 6" EMBED, 12"Ø SELF-CUTTING ANCHOR BOLT w/ 4" EMBED, OR SIMPSON FWAZ ANCHOR SAND (30 PSF/FT) SANDY CLAY (45 PSF/FT) CLAY (60 PSF/FT) 6'-0" OR LESS 60" 72" 30" 36" 72" 18" 24" 42" 72" 72" 24" 18" 20" 24" 18" 24" 24" 30" 42" 16" 12" 14" 16" 12" 16" 36" 36" N/A N/A COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 1511 1.001 January 1, 2021 S11 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS ANCHOR SPACING TABLES Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 NAIL SHEATHING TO BLOCKING/JOISTS0.131 Ø x 3" LONG NAILS @ 6" O.C.STRUCTURAL RIM BOARD BY OTHERSTYPE D CONNECTOR @ BLOCKING SEES102 x 6 MINSILL PLATEFOUNDATION WALL SEE OTHER SHEETSFOR ANCHORS & WALL INFOSLOPE GRADE AWAY FROMFOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MINSPACERS UNTIL SPACES IN WHICH FULLHEIGHT BLOCKING CAN BE INSTALLED,TOE NAIL TO FLOOR MEMBERS EACH ENDw/ (12) 0.131"Øx3" LONG NAILSFRAMINGBY OTHERSOPTIONAL OPEN SPACE AS SHOWN ORSHIFT FULL HEIGHT BLOCKINGPROVIDE BLOCKINGAS REQUIRED TO ACHIEVENAILING SHOWN. (MIN 2SPACES) BLOCKING HEIGHTTO MATCH JOIST DEPTH &BE OF LUMBER, I-JOIST, OROTHER MANUFACTUREDMATERIAL ATTACHBLOCKING TO JOISTS w/ TOENAILS EACH ENDJOISTS BY OTHERSSEE S11 FOR SPACING OFBLOCKING SYSTEM SHOWNNOTES:1. MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x3" LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2. NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3. BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTHMEMBER BLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD.NAILING SHOWN IS TO BE USED AT MINIMUM.4. BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5. HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE. COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 1512 1.001 January 1, 2021 S12 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS NON BEARING JOIST BLOCKING DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 NAIL SHEATHING TO BLOCKING/TRUSSESw/ (12) 0.131"Øx3" LONG NAILSDUCT/MECHANICAL (AS REQUIRED)BY OTHERSFRAMINGBY OTHERS0.131 Ø x 3" LONGNAILS @ 6" O.C.RIM TRUSSBY OTHERSTOP NAIL RIM TO SILLw/ MIN OF (12)0.131 Ø x3" LONG NAILS EACHSIDE OF BLOCKING ORTYPE D CONNECTOR @BLOCKING SEE S102 x 6 MINSILL PLATEFOUNDATION WALL SEEOTHER SHEETS FORANCHORS & WALL INFOSLOPE GRADE AWAY FROMFOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MIN SPACERSTOP & BOTTOM AT MECHANICAL UNTILSPACES IN WHICH BLOCKING CAN BEINSTALLED, TOE NAIL TO FLOOR MEMBERSw/ (2) 0.131 Ø x 3" LONG NAILS3/4" PLYWOOD/OSB ONE SIDEOF BLOCKING w/ (6) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMOR 1/2" PLYWOOD/OSB EACHSIDE OF BLOCKING EACH w/(4) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMPROVIDE 2 x 4 MIN BLOCKINGTOP & BOTTOM OF TRUSSESAS REQUIRED TO ACHIEVENAILING SHOWN.INSTALL w/ (2) 0.131 Ø x 3"LONG TOE NAILSTRUSSES BY OTHERSNOTES:1. MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x 3"LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2. NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3. BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTH MEMBERBLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD. NAILING SHOWN IS TOBE USED AT MINIMUM.4. BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5. HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE.SEE S11 FOR SPACING OFBLOCKING SYSTEM SHOWN COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 1513 1.001 January 1, 2021 S13 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS NON-BEARING TRUSS BLOCKING DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 10'-0" MAX3'-8" MAX2'-6" MIN OPENING1'-6" MIN3'-0" EACH WAY MIN 112" TYPSLOPE GRADE AWAY FROM FOUNDATION #4 HORIZONTAL BARS @ 12" O.C. CENTERED IN WALLS LAP AROUND CORNERS AND HOOK INTO FOUNDATION WALL @ EACH SIDE (REFER TO S7 FOR HORZ. BAR REQUIREMENTS w/ 8" C.I.P. WALLS) 6" MIN C.I.P. CONCRETE WALL #4 VERTICAL BARS @ EACH OUTSIDE CORNER OF WELL (1)#4 x2'-0" DOWEL @ EACH OUTSIDE CORNER OF WELL (5" MIN EMBED) 12" WIDE x 8" THICK MIN STRIP FOOTING (1) #4 HORIZONTAL BAR AT TOP OF WALL (2) #4 HORIZONTAL BARS TOP & BOTTOM OF LINTEL EXTEND 24" MIN PAST OPENING EACH END (WOOD OR STEEL OPTION BY OTHERS) WALL BEYOND PLACE (2) #4 VERTICAL BARS FULL HEIGHT AND ONE ANCHOR w/IN 12" OF OPENING EACH END 8" MIN C.I.P. CONCRETE WALL SLAB-ON-GRADE UNREINFORCED CONCRETE STRIP FOOTING SEE FULL HEIGHT WALL SECTION S7 LOOKOUT WALL SEE S5 GRANULAR MATERIAL (SAND) SLOPE WINDOW WELL LADDER/ ESCAPE MEANS BY OTHERS 5'-0" EACH WAY MAX FLOOR SYSTEM BY OTHERS (DO NOT PLACE GIRDERS OR BEAMS OVER CONCRETE LINTEL DESIGNED FOR 1500 PLF)IF CONCRETEOPTIONAL RIGID INSULATION w/IN WINDOW WELL AT THE DISCRETION OF THE BUILDER FOR ADDITIONAL FROST PROTECTION AS REQUIRED PER SITE DESIGN 6" MIN. COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 1514 1.001 January 1, 2021 S14 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS WINDOW WELL DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6'-0" MAX. 8" MIN. GRAD E L I N E 9'-4" MAX.6'-0" MAX.4'-0" MAX.SEE BASEMENT WALL DETAILSEE LOOKOUT WALL DETAILSIM.CONSTRUCT SIM. LOOKOUT WALLw/ MIN. (2) #4 HORIZ. BARS3 MIN. 1 S7S5S5SLAB-ON-GRADE BEYOND CONCRETE STRIP FOOTING STEP DOWN AS REQ'D FOR FROST PROTECTION AT NON-BEARING WALLS, LOCATE BLOCKING DETAILS (S12 / S13) AT END OF FULL HEIGHT WALL PROVIDE (2) ADDITIONAL #4 BARS @ END OF FULL HEIGHT WALL SEGMENT LOCATED 2" FROM INSIDE WALL FACE FLOOR FRAMING ABOVE BY OTHERS INFILL WOOD FRAMING BY OTHERS COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 1515 1.001 January 1, 2021 S15 Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS STEPPING DOWN WALL WITH GRADE    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 1 Ventilation, Makeup and Combustion Air Calculations Submittal Form For New Dwellings Site address Date Contractor Completed By Section A Ventilation Quantity (Determine quantity by using Table N1104.2 or Equation 11‐1) Square feet (Conditioned area including basement – finished or unfinished) Number of bedrooms Total required ventilation Continuous ventilation Directions ‐ Determine the total and continuous ventilation rate by either using Table N1104.2 or equation 11‐1. The table and equation are below. Table N1104.2 Total and Continuous Ventilation Rates (in cfm) Number of Bedrooms 1 2 3 4 5 6 Conditioned space (in sq. ft.) Total/ continuous Total/ continuous Total/ continuous Total/ continuous Total/ continuous Total/ continuous 1000‐1500 60/40 75/40 90/45 105/53 120/60 135/68 1501‐2000 70/40 85/43 100/50 115/58 130/65 145/73 2001‐2500 80/40 95/48 110/55 125/63 140/70 155/78 2501‐3000 90/45 105/53 120/60 135/68 150/75 165/83 3001‐3500 100/50 115/58 130/65 145/73 160/80 175/88 3501‐4000 110/55 125/63 140/70 155/78 170/85 185/93 4001‐4500 120/60 135/68 150/75 165/83 180/90 195/98 4501‐5000 130/65 145/73 160/80 175/88 190/95 205/103 5001‐5500 140/70 155/78 170/85 185/93 200/100 215/108 5501‐6000 150/75 165/83 180/90 195/98 210/105 225/113 Equation 11‐1 (0.02 x square feet of conditioned space) + [15 x (number of bedrooms + 1)] = Total ventilation rate (cfm) Total ventilation – The mechanical ventilation system shall provide sufficient outdoor air to equal the total ventilation rate average, for each one‐hour period according to the above table or equation. For heat recovery ventilators (HRV) and energy recovery ventila‐ tors (ERV) the average hourly ventilation capacity must be determined in consideration of any reduction of exhaust or out outdoor air intake, or both, for defrost or other equipment cycling. Continuous ventilation ‐ A minimum of 50 percent of the total ventilation rate, but not less than 40 cfm, shall be provided, on a con‐ tinuous rate average for each one‐hour period. The portion of the mechanical ventilation system intended to be continuous may have automatic cycling controls providing the average flow rate for each hour is met. 16411 ABERDEEN ST NE,HAM LAKE, MN 55304 2 Section B Ventilation Method (Choose either balanced or exhaust) Balanced, HRV (Heat Recovery Ventilator) or ERV (Energy Recov‐ ery Ventilator) – cfm of unit in low must not exceed continuous venti‐ lation rating by more than 100%. Exhaust only (Continuous fan rating in cfm) Low cfm: High cfm: Continuous fan rating in cfm (capacity must not exceed continuous ventilation rating by more than 100%) Directions ‐ Choose the method of ventilation, balanced or exhaust only. Balanced ventilation systems are typically HRV or ERV’s. Enter the low and high cfm amounts. Low cfm air flow must be equal to or greater than the required continuous ventilation rate and less than 100% greater than the continuous rate. (For instance, if the low cfm is 40 cfm, the ventilation fan must not exceed 80 cfm.) Automatic controls may allow the use of a larger fan that is operated a percentage of each hour. Section C Ventilation Fan Description Location Continuous Intermittent Directions ‐ The ventilation fan schedule should describe what the fan is for, the location, cfm, and whether it is used for continuous or intermittent ventilation. The fan that is chose for continuous ventilation must be equal to or greater than the low cfm air rating and less than 100% greater than the continuous rate. (For instance, if the low cfm is 40 cfm, the continuous ventilation fan must not exceed 80 cfm.) Automatic controls may allow the use of a larger fan that is operated a percentage of each hour. Section D Ventilation Controls Directions ‐ Describe operation and control of the continuous and intermittent ventilation. There should be adequate detail for plan reviewers and inspectors to verify design and installation compliance. Related trades also need adequate detail for placement of controls and proper operation of the building ventilation. If exhaust fans are used for building ventilation, describe the operation and location of any controls, indicators and legends. If an ERV or HRV is to be installed, describe how it will be installed. If it will be connected and interfaced with the air handling equipment, please describe such connections as detailed in the manufactures’ installation instructions. If the installation instructions require or recommend the equipment to be interlocked with the air handling equipment for proper operation, such interconnection shall be made and described. 3 Section E Make‐up air Passive (determined from calculations from Table 501.3.1) Powered (determined from calculations from Table 501.3.1) Interlocked with exhaust device (determined from calculation from Table 501.3.1) Other, describe: Location of duct or system ventilation make‐up air: Determined from make‐up air opening table Cfm Size and type (round, rectangular, flex or rigid) Directions ‐ In order to determine the makeup air, Table 501.3.1 must be filled out (see below). For most new installations, column A will be appropriate, however, if atmospherically vented appliances or solid fuel appliances are installed, use the appropriate column. For existing dwellings, see IMC 501.3.3. Please note, if the makeup air quantity is negative, no additional makeup air will be re‐ quired for ventilation, if the value is positive refer to Table 501.3.2 and size the opening. Transfer the cfm, size of opening and type (round, rectangular, flex or rigid) to the last line of section D. The make‐up air supply must be installed per IMC 501.3.2.3. Table 501.3.1 PROCEDURE TO DETERMINE MAKEUP AIR QUANITY FOR EXHAUST EQUIPMENT IN DWELLINGS (Additional combustion air will be required for combustion appliances, see KAIR method for calculations) One or multiple power vent or direct vent appliances or no combustion appliances Column A One or multiple fan‐ assisted appliances and power vent or direct vent appliances Column B One atmospherically vent gas or oil appliance or one solid fuel appliance Column C Multiple atmospherically vented gas or oil appliances or solid fuel appliances Column D 1. a) pressure factor (cfm/sf) 0.15 0.09 0.06 0.03 b) conditioned floor area (sf) (including unfinished basements) Estimated House Infiltration (cfm): [1a x 1b] 2. Exhaust Capacity a) continuous exhaust‐only ventilation system (cfm); (not applicable to balanced ventilation systems such as HRV) b) clothes dryer (cfm) 135 135 135 135 c) 80% of largest exhaust rating (cfm); Kitchen hood typically (not applicable if recirculating system or if powered makeup air is electrically interlocked and match to exhaust) d) 80% of next largest exhaust rating (cfm); bath fan typically (not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust) Not Applicable Total Exhaust Capacity (cfm); [2a + 2b +2c + 2d] 3. Makeup Air Quantity (cfm) a) total exhaust capacity (from above) b) estimated house infiltration (from above) Makeup Air Quantity (cfm); [3a – 3b] (if value is negative, no makeup air is needed) 4. For makeup Air Opening Sizing, refer to Table 501.4.2 A. Use this column if there are other than fan‐assisted or atmospherically vented gas or oil appliance or if there are no combustion appliances. (Power vent and direct vent appliances may be used.) B. Use this column if there is one fan‐assisted appliance per venting system. (Appliances other than atmospherically vented appliances may be included.) C. Use this column if there is one atmospherically vented (other than fan‐assisted) gas or oil appliance per venting system or one solid fuel appliance. D. Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid fuel appliances. 4 Makeup Air Opening Table for New and Existing Dwelling Table 501.3.2 One or multiple power vent, direct vent appliances, or no combustion appliances Column A One or multiple fan‐ assisted appliances and power vent or direct vent appliances Column B One atmospherically vented gas or oil appliance or one solid fuel appliance Column C Multiple atmospherically vented gas or oil appliances or solid fuel appliances Column D Duct diameter Passive opening 1 – 36 1 – 22 1 – 15 1 – 9 3 Passive opening 37 – 66 23 – 41 16 – 28 10 – 17 4 Passive opening 67 – 109 42 – 66 29 – 46 18 – 28 5 Passive opening 110 ‐ 163 67 – 100 47 – 69 29 – 42 6 Passive opening 164 – 232 101 – 143 70 – 99 43 – 61 7 Passive opening 233 – 317 144 – 195 100 – 135 62 – 83 8 Passive opening w/motorized damper 318 – 419 196 – 258 136 – 179 84 – 110 9 Passive opening w/motorized damper 420 – 539 259 – 332 180 – 230 111 – 142 10 Passive opening w/motorized damper 540 – 679 333 – 419 231 – 290 143 – 179 11 Powered makeup air >679 >419 >290 >179 NA Notes: A. An equivalent length of 100 feet of round smooth metal duct is assumed. Subtract 40 feet for the exterior hood and ten feet for each 90‐ degree elbow to determine the remaining length of straight duct allowable. B. If flexible duct is used, increase the duct diameter by one inch. Flexible duct shall be stretched with minimal sags. Compressed duct shall not be accepted. C. Barometric dampers are prohibited in passive makeup air openings when any atmospherically vented appliance is installed. D. Powered makeup air shall be electrically interlocked with the largest exhaust system. Section F Combustion Not required per mechanical code (No atmospheric or power vented appliances) Passive (see IFGC Appendix E, Worksheet E‐1) Size and type Other, describe: Explanation ‐ If no atmospheric or power vented appliances are installed, check the appropriate box, not required. If a power vented or atmospherically vented appliance installed, use IFGC Appendix E, Worksheet E‐1 (see below). Please enter size and type. Combustion air vent supplies must communicate with the appliance or appliances that require the combustion air. Section F calculations follow on the next 2 pages. 5 Directions ‐ The Minnesota Fuel Gas Code method to calculate to size of a required combustion air opening, is called the Known Air Infiltration Rate Method. For new construction, 4b of step 4 is required to be filled out. IFGC Appendix E, Worksheet E‐1--Residential Combustion Air Calculation Method (for Furnace, Boiler, and/or Water Heater in the Same Space) Step 1: Complete vented combustion appliance information. Furnace/Boiler: Draft Hood Fan Assisted Direct Vent Input: ______________________Btu/hr or Power Vent Water Heater: Draft Hood Fan Assisted Direct Vent Input: ______________________Btu/hr or Power Vent Step 2: Calculate the volume of the Combustion Appliance Space (CAS) containing combustion appliances. The CAS includes all spaces connected to one another by code compliant openings. CAS volume: ft3 L x W x H L W H Step 3: Determine Air Changes per Hour (ACH)1 Default ACH values have been incorporated into Table E‐1 for use with Method 4b (KAIR Method). If the year of construction or ACH is not known, use method 4a (Standard Method). Step 4: Determine Required Volume for Combustion Air. (DO NOT COUNT DIRECT VENT APPLIANCES) 4a. Standard Method Total Btu/hr input of all combustion appliances Input: Btu/hr Use Standard Method column in Table E‐1 to find Total Required TRV: ft3 Volume (TRV) If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed. If CAS Volume (from Step 2) is less than TRV then go to STEP 5. 4b. Known Air Infiltration Rate (KAIR) Method (DO NOT COUNT DIRECT VENT APPLIANCES) Total Btu/hr input of all fan‐assisted and power vent appliances Input: Btu/hr Use Fan‐Assisted Appliances column in Table E‐1 to find RVFA: ft3 Required Volume Fan Assisted (RVFA) Total Btu/hr input of all Natural draft appliances Input: Btu/hr Use Natural draft Appliances column in Table E‐1 to find RVNFA: ft3 Required Volume Natural draft appliances (RVNDA) Total Required Volume (TRV) = RVFA + RVNDA TRV = + = TRV ft3 If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed. If CAS Volume (from Step 2) is less than TRV then go to STEP 5. Step 5: Calculate the ratio of available interior volume to the total required volume. Ratio = CAS Volume (from Step 2) divided by TRV (from Step 4a or Step 4b) Ratio =______ /_______ =_______________ Step 6: Calculate Reduction Factor (RF). RF = 1 minus Ratio RF = 1 ‐ __________________=__________________ Step 7: Calculate single outdoor opening as if all combustion air is from outside. Total Btu/hr input of all Combustion Appliances in the same CAS Input: Btu/hr (EXCEPT DIRECT VENT) Combustion Air Opening Area (CAOA): Total Btu/hr divided by 3000 Btu/hr per in2 CAOA =___________________/ 3000 Btu/hr per in2 =_____________________in2 Step 8: Calculate Minimum CAOA: Minimum CAOA = CAOA multiplied by RF Minimum CAOA =________________ x____________________ =__________ in2 Step 9: Calculate Combustion Air Opening Diameter (CAOD): CAOD = 1.13 multiplied by the square root of Minimum CAOA CAOD = 1.13 √ Minimum CAOA = in. diameter go up one inch in size if using flex duct 1 If desired, ACH can be determined using ASHRAE calculation or blower door test. Follow procedures in Section G304. 6 IFGC Appendix E, Table E‐1 Residential Combustion air (Required Interior Volume Based on Input Rating of Appliance) Input Rating (Btu/hr) Standard Method Known Air Infiltration Rate (KAIR) Method (cu ft) Fan Assisted or Power Vent Natural Draft 1994 to present Pre‐1994 1994 to present Pre‐1994 5,000 250 375 188 525 263 10,000 500 750 375 1,050 525 15,000 750 1,125 563 1,575 788 20,000 1,000 1,500 750 2,100 1,050 25,000 1,250 1,875 938 2,625 1,313 30,000 1,500 2,250 1,125 3,150 1,575 35,000 1,750 2,625 1,313 3,675 1,838 40,000 2,000 3,000 1,500 4,200 2,100 45,000 2,250 3,375 1,688 4,725 2,363 50,000 2,500 3,750 1,675 5,250 2,625 55,000 2,750 4,125 2,063 5,775 2,888 60,000 3,000 4,500 2,250 6,300 3,150 65,000 3,250 4,875 2,438 6,825 3,413 70,000 3,500 5,250 2,625 7,350 3,675 75,000 3,750 5,625 2,813 7,875 3,938 80,000 4,000 6,000 3,000 8,400 4,200 85,000 4,250 6,375 3,188 8,925 4,463 90,000 4,500 6,750 3,375 9,450 4,725 95,000 4,750 7,125 3,563 9,975 4,988 100,000 5,000 7,500 3,750 10,500 5,250 105,000 5,250 7,875 3,938 11,025 5,513 110,000 5,500 8,250 4,125 11,550 5,775 115,000 5,750 8.625 4,313 12,075 6,038 120,000 6,000 9,000 4,500 12,600 6,300 125,000 6,250 9,375 4,688 13,125 6,563 130,000 6,500 9,750 4,875 13,650 6,825 135,000 6,750 10,125 5,063 14,175 7,088 140,000 7,000 10,500 5,250 14,700 7,350 145,000 7,250 10,875 5,438 15,225 7,613 150,000 7,500 11,250 5,625 15,750 7,875 155,000 7,750 11,625 5,813 16,275 8,138 160,000 8,000 12,000 6,000 16,800 8,400 165,000 8,250 12,375 6,188 17,325 8,663 170,000 8,500 12,750 6,375 17,850 8,925 175,000 8,750 13,125 6,563 18,375 9,188 180,000 9,000 13,500 6,750 18,900 9,450 185,000 9,250 13,875 6,938 19,425 9,713 190,000 9,500 14,250 7,125 19,950 9,975 195,000 9,750 14,625 7,313 20,475 10,238 200,000 10,000 15,000 7,500 21,000 10,500 205,000 10,250 15,375 7,688 21,525 10,783 210,000 10,500 15,750 7,875 22,050 11,025 215,000 10,750 16,125 8,063 22,575 11,288 220,000 11,000 16,500 8,250 23,100 11,550 225,000 11,250 16,875 8,438 23,625 11,813 230,000 11,500 17,250 8,625 24,150 12,075 1. The 1994 date refers to dwellings constructed under the 1994 Minnesota Energy Code. The default KAIR used in this section of the table is 0.20 ACH. 2. This section of the table is to be used for dwellings constructed prior to 1994. The default KAIR used in this section of the table is 0.40 ACH. HVAC Load Calculations for Country Joe Homes 18737 Javelin Ct Lakeville, MN 55044 Prepared By: Samantha Lykke Air Mechanical 16411 Aberdeen St NE Ham Lake, MN 55304 Tuesday, January 18, 2022 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air Mechanical Inc. Ham Lake, MN 55304 Page 2 Project Report General Project Information Project Title: Project Date:Tuesday, January 18, 2022 Client Name:Country Joe Homes Client Address:18737 Javelin Ct Client City:Lakeville, MN 55044 Company Name:Air Mechanical Company Representative:Samantha Lykke Company Address:16411 Aberdeen St NE Company City:Ham Lake, MN 55304 Design Data Reference City:Minneapolis, Minnesota Building Orientation:Front door faces West Daily Temperature Range:Medium Latitude:44 Degrees Elevation:834 ft. Altitude Factor:0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter:-15 -12.38 n/a 30%72 29.40 Summer:88 73 50%50%74 37 Check Figures Total Building Supply CFM:1,459 CFM Per Square ft.:0.286 Square ft. of Room Area:5,096 Square ft. Per Ton:1,428 Volume (ft³):33,583 Building Loads Total Heating Required Including Ventilation Air:90,871 Btuh 90.871 MBH Total Sensible Gain:32,631 Btuh 76 % Total Latent Gain:10,184 Btuh 24 % Total Cooling Required Including Ventilation Air:42,815 Btuh 3.57 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\Users\Slykke\Desktop\18737 Javelin Ct.rh9 Tuesday, January 18, 2022, 8:09 AM Date Certificate Posted Passive (No Fan) Active (With fan and monometer or other system monitoring device ) Location (or future location) of Fan: Other Please Describe Here X R-15 X X R-20 X R-20 X R-21 X R-49 X R-49 X R-30 X X Not applicable, all ducts located in conditioned space R-8 X Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS: 100,000 Capacity in Gallons: Other, describe: AFUE or HSPF% 92% Cfm's " round duct OR " metal duct Not required per mech. code Passive Low: Other, describe: X Low: Location of fan(s), describe: Cfm's " FLEX OR " metal duct THERMAL ENVELOPE Foam Open Cell Wall Below Entire Slab Rigid, Extruded Polystyrene Ceiling, flat Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area Rim Joist (2nd Floor+) 0.29 Appliances Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM Non or Not Applicable Cooling System Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel.Place your logo here New Construction Energy Code Compliance Certificate Name of Residential Contractor Country Joe Homes MN License Number Lakeville18737 Javelin Ct BC627670 City Mailing Address of the Dwelling or Dwelling Unit FLEX MECH ROOM Heat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: 90,871 Heating Gain Cooling Load 100 200 Select Type RENEW AIRE EV-200 (BALANCED) Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): 32,631Residential Load Calculation Heating Loss Combustion Air Select a Type Location of duct or system: 42,815Total R-Value of all Types of InsulationType: Check All That Apply Mineral Fiberboard Insulation Location Foam, Closed Cell0.28 Describe other insulated areas Fiberglass, BlownFiberglass, Batts Foundation Wall R-value Average U-Factor (excludes skylights and one door ) U: Duct system air tightness: Building envelope air tightness: Rim Joist (1st Floor) WEG100C2X045 BA13NA048 Model Heating System Natural gas BRYANT Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Electric Make-up Air Select a Type Westinghouse Domestic Water Heater MECHANICAL SYSTEMS Rating or Size Efficiency 13SEER /EER 912SD60100 Manufacturer BRYANT Electric Output in Tons: 4100 Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Capacity continuous ventilation rate in cfms: Builders Associaton of Minnesota version 101014 3/16/22YAM