Loading...
HomeMy WebLinkAbout18599 Hidden Way Survey(1062.2)(1057.4)(1059.4)GARAGE PROPOSED HOUSE 105 1010454510 5 5 5 PORTION OF EASEMENT TO BE VACATEDN:175797.79E:520798.92EL:1063.3FD IPFD IPN:175852.27E:520781.29EL:1060.7N:175846.93E:520791.08EL:1060.0N:175866.72 E:520804.10 EL:1058.5 N:175812.01E:520820.96EL:1060.21061.11060.41059.71059.81059.81059.41057.71059.51057.41057.01059.31060.01061.01056.81057.71059.81059.01058.91060.51060.5VACANT LOTVACANT LOT1056.21054.61054.31060.01055.4(1061.9)(1060.9)(1062.60)(1057.4)(1062.2)(1060.2)(1057.7)(1061.0)POR S.W.DRAINAGE &UTILITY EASEMENT25.337.6% 18.33 9.00 3.00 28.67 35.67 11.67 3.00 5.67 13.17 36.50 24.50 16.17 149.33N89°45'08"E70.00 S00°14'52"E N00°05'55"W 70.00 N89°45'08"E149.15HIDDEN WAY HIGHVIEW AVENUE 1055.8(1055.5)(1054.0)LOOKOUT(1057.4)(1054.8)DITCH TO DAYLIGHT (1054.4)(1056.0)EDGE OF BITUMINOUS 9.1778.017.00 (1056.9)(1055.1)2' CANT. OS 26.50 NAIL=1059.16 OS 7.00 NAIL=1060.75 OS 32.17 NAIL=1058.15 OS 9.17 NAIL=1055.35DENOTES EXISTING CATCH BASINDENOTES EXISTING HYDRANTDENOTES EXISTING SANITARY MANHOLEDENOTES EXISTING STORM MANHOLEDENOTES EXISTING UTILITY BOXDENOTES EXISTING SERVICE OR CLEANOUTDENOTES IRON MONUMENT FOUNDDENOTES IRON MONUMENT SETDENOTES EXISTING POWER POLEDENOTES EXISTING LIGHT POLEDENOTES EXISTING CONSERVATION POSTOR WET LAND BUFFER POSTDENOTES EXISTING TREE8" TREE000.0DENOTES WOOD HUBDENOTES NAILDENOTES EXISTING RETAINING WALLDENOTES PROPOSED RETAINING WALLDENOTES EXISTING ELEVATIONDENOTES PROPOSED ELEVATIONDENOTES AS BUILT ELEVATION(000.0)000.0DENOTES EXISTING TREELINEDENOTES DIRECTION OF SURFACE DRAINAGEDENOTES EXISTING FENCELEGENDDENOTES EXISTING F.E.S.LOT AREA : 10,447 SQ. FT.HOUSE AREA : 1,902 SQ. FT.BUILDING COVERAGE AREA : 1,959 SQ. FT. (18.8%)PORCH AREA : 48 SQ. FT.Legal Description:= FINISHED GARAGE FLOOR ELEVATION= BASEMENT FLOOR ELEVATION= TOP OF FOUNDATION ELEVATION(1062.60)(1062.93)(1054.93)1. No specific soils investigation has been performed on this lotby the surveyor. The suitability of the soils to support thespecific house is not the responsibility of the surveyor.2.No title information was provided for this survey. This surveydoes not purport to show all easements of record.3. See architectural plans for final building dimensions.CERTIFICATE OF SURVEYNOTES1. 1054.6 MINIMUM LOW FLOOR2. 24FT MAXIMUM DRIVEWAY WIDTH AT RIGHT OF WAY WITHOUT PERMIT.3. ROCK CONSTRUCTION ENTRANCE AT DRIVEWAY. 4. EROSION CONTROL AT GRADING LIMITS.Zoning = RS-4FY - 20' House, 25' GarageSY - 7' Interior, 20' CornerRY - 30'SY Buffer - 30'RY Buffer - 50'The curb box, drain tile cleanout, and catchbasin(if applicable) must be inspected andaccepted before As-Built escrow monies willbe released. All structures must be flushwith the sod. This will be scheduled with thelandscape inspection.*Draintile connection required.*Maintain 6" between bottom of siding and sod.*No structures in easements.EROSION CONTROLMUST BE INSTALLEDBEFORE EXCAVATIONENGINEERING REVIEWEDDate:__________________03/17/2022lritchie