Loading...
HomeMy WebLinkAboutLA186780 - 223 Cleopatra Dr Setup Permit12/2/2020 DE OFFICE USE ONLY MANUFACTURED HOME PERMIT APPLICATION USE AND OCCUPANCY: _____ _____ _____ _____ REQUIRED INSPECTIONS: FOOTING TIE-DOWNS AND BLOCKING BUILDING FINAL (copy of Systems Test Affidavit) PERMIT FEE: PERMIT FEE: $____________________ SURCHARGE: $____________________ TOTAL: $____________________ BUILDING INSPECTOR: __________________________ DATE:__________________________ COMMENTS: BUILDING CODE CONSTRUCTION TYPE IRC DWELLING TYPE ZONING 8/3/20 5:46 PM; Generated by Rose Graham ClaytonGO: Foundation Plan Summary Order Number:N/A Model Number:995-4028-751 Home Building Facility:N/A Home Width:27 FT 0 IN Home Length:40 FT 0 IN Outrigger Length (O.R.):31.25 IN Chassis Spacing:99.5 IN Roof Load:30 PSF Soil Bearing Cap:1500 PSF Min. I-Beam Size:8 IN Max. Eave/Overhang:9 IN Use this QR Code to access DAPIA approved tables referenced within this design. Hover your iPhone camera over the code. For Android and other devices, download a QR Code reader. TABLE 1: FRAME PIERS Pier Spacing Pier Configuration Footer Size TYP. 7 FT 2 IN Single stacked 28 IN Diameter x 10 IN MAX. 8 FT 0 IN Single stacked 28 IN Diameter x 10 IN (Table 6b) TABLE 3: MARRIAGE WALL PIERS Pier ID Pier Configuration Footer Size M1 Single stacked 26 IN Diameter x 9 IN M2 Single stacked 26 IN Diameter x 9 IN (Table 5b) NOTES: 1. FROST PROTECTION WILL BE PROVIDED BY PLACING FOOTERS BELOW FROST DEPTH OF 35 INCHES PER (FIGURE 5A) OR FROM LAHJ. Frost depth for interior footers may be taken as half with R5 skirting per (Table 4a) [3285.312(b)] 2. HOME HAS BEEN BUILT WITH ADDITIONAL FLOOR JOIST AT SIDEWALL OPENINGS TO ELIMINATE NEED OF SIDEWALL PIERS. SIDEWALL PIERS SHALL BE PLACED WHERE INDICATED BY PIER TAGS ON HOME. 3. ALL FOOTERS WILL BE POURED CONCRETE. ALL SINGLE STACKED PIERS WILL HAVE A MINIMUM THICKNESS OF 10 INCHES with footer depth extending below frost depth using 3,000 PSI minimum concrete (table 10A) (table 8) 4. THIS PIER LAYOUT HAS BEEN DERIVED USING PE SEALED & DAPIA APPROVED INSTALLATION MANUAL AS OUTLINED ABOVE. PLEASE SEE INSTALLATION MANUAL FOR PE SEAL AND DAPIA APPROVAL. (Reference to Clayton Homes DAPIA approved Installation manual) [Reference to Federal Statutes 24 CFR Part 3280, 3285 or 3286]FRONT2' 0"9' 2"16' 5"23' 7"30' 10"38' 0" 15' 0" M1 29' 3" M2 6,414 lbs bearing capacity to be achieved by helicals 5,531 lbs bearing capacity to be achieved by helicals Concept Approval ONLY Subject to Field Inspection Inspector Date 2020 MN Bldg Code 12/09/2020dmathews