Loading...
HomeMy WebLinkAboutLA200505 Permit PackGA 12/10/21 Plans3-28-2022 Emailed 200505 $730.43 27000 434.50 282.43 13.50 730.43 x x x x x x x Gene Abbott 3/28/22 Planning approved 3/28/22 10280 S. Oak Shore Dr.Justin AndersonLakeville, MN 55044651-331-6135city sewer and waterBProvide copy of city approved planson the job site for the inspectorConcept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode03/28/2022gabbott 10280 S. Oak Shore Dr.Justin AndersonLakeville, MN 55044651-331-6135See structuraldrawingsSpray foambeing used asper contractor 10280 S. Oak Shore Dr.Justin AndersonLakeville, MN 55044651-331-6135Emergency escape and rescue window required inall bedrooms. 44" maximum sill height, minimum 5.7square feet opening, minimum clear opening heightof 24 inches, minimum clear opening width of 20inches. operational from inside of room without keys,tools or special knowledge.529.45 sf See included beam calcs for revised beam at existing house wall for new openings in the wall. Item not found. Provide design data Item not found. Provide design data CB66 as per engineer email information submitted 3/19/21 0 12 09-05-00 09-05-00 B1 B2 B3 0 1 Total Horizontal Product Length = 19-04-00 Page 1 of 2 Triple 1-3/4"x 7-1/4"VERSA-LAM®LVL 2.1E 3100 SP RB01 (Roof Drop Beam) BC CALC®Member Report Dry |2 spans |No cant.May 5,2022 10:13:08 Build 8381 Job name:Justin Anderson File name:Justin Anderson Roof Beam Calc Address:10280 S.Oak Shore Dr Description: City,State,Zip:Lakeville,MN,55044 Specifier:Job Site Customer:Arrow -Red Wing Designer:Anthony Estevez Code reports:ESR-1040 Company:Boise Cascade Page 1 of 2 Reaction Summary (Down /Uplift)(lbs)Bearing Live Dead Snow Wind Roof Live B1,3"1246 /0 2271 /0 B2,3-1/2"3907 /0 6610 /0 B3,3"1246 /0 2271 /0 Load Summary Live Dead Snow Wind Roof Live Tributary Tag Description Load Type Ref.Start End Loc.100%90%115%160%125% 0 Self-Weight Unf.Lin.(lb/ft)L 00-00-00 19-04-00 Top 11 00-00-00 1 Standard Load Unf.Area (lb/ft²)L 00-00-00 19-04-00 Top 20 35 16-00-00 Controls Summary Value %Allowable Duration Case Location Pos.Moment 6298 ft-lbs 43.6%115%7 03-11-09 Neg.Moment -9816 ft-lbs 67.9%115%9 09-08-00 End Shear 2756 lbs 33.1%115%7 00-10-04 Cont.Shear 4590 lbs 55.2%115%9 08-11-00 Total Load Deflection L/428 (0.266")42.1%n\a 8 14-10-15 Live Load Deflection L/624 (0.182")38.5%n\a 10 04-06-00 Total Neg.Defl.L/999 (-0.002")n\a n\a 8 09-02-10 Max Defl.0.266"26.6%n\a 7 04-05-01 Span /Depth 15.7 Bearing Supports Dim.(LxW)Value %Allow Support %Allow Member Material B1 Wall/Plate 3"x 5-1/4"3517 lbs n\a 29.8%Unspecified B2 Wall/Plate 3-1/2"x 5-1/4"10517 lbs n\a 76.3%Unspecified B3 Wall/Plate 3"x 5-1/4"3517 lbs n\a 29.8%Unspecified Cautions For roof members with slope (1/4)/12 or less final design must ensure that ponding instability will not occur. For roof members with slope (1/2)/12 or less final design must account for Rain-on-Snow surcharge load. Notes Design meets Code minimum (L/180)Total load deflection criteria. Design meets Code minimum (L/240)Live load deflection criteria. Design meets arbitrary (1")Maximum Total load deflection criteria. Design based on Dry Service Condition. BC CALC®analysis is based on IBC 2018. Calculations assume member is fully braced. DisclosureUseoftheBoiseCascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy,prior to anyone relying on such output as evidence of suitability for a particular application.The output here is based on building code-accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes.To obtain Installation Guide or ask questions,please call (800)232-0788 before installation. BC CALC®,BC FRAMER®,AJS™, ALLJOIST®,BC RIM BOARD™,BCI®, BOISE GLULAM™,BC FloorValue®, VERSA-LAM®,VERSA-RIM PLUS®, Page 2 of 2 Triple 1-3/4"x 7-1/4"VERSA-LAM®LVL 2.1E 3100 SP RB01 (Roof Drop Beam) BC CALC®Member Report Dry |2 spans |No cant.May 5,2022 10:13:08 Build 8381 Job name:Justin Anderson File name:Justin Anderson Roof Beam Calc Address:10280 S.Oak Shore Dr Description: City,State,Zip:Lakeville,MN,55044 Specifier:Job Site Customer:Arrow -Red Wing Designer:Anthony Estevez Code reports:ESR-1040 Company:Boise Cascade Page 2 of 2 Connection Diagram:Full Length of Member a minimum =2"c =2-1/4" b minimum =3"d =24" e minimum =3" Calculated Side Load =0.0 lb/ft Nailing applies to both sides of the member Connectors are:3-1/4 in.Pneumatic Gun Nails 0 12 07-00-00 07-00-00 07-00-00 B1 B2 B3 B4 0 1 Total Horizontal Product Length = 21-06-00 Page 1 of 2 Triple 1-3/4"x 7-1/4"VERSA-LAM®LVL 2.1E 3100 SP RB01 (Roof Drop Beam) BC CALC®Member Report Dry |3 spans |No cant.May 4,2022 12:52:46 Build 8381 Job name:Remodel -Roof Header File name: Address:Description: City,State,Zip:Specifier:Chris N. Customer:Arrow -Red Wing Designer:Anthony Estevez Code reports:ESR-1040 Company:Boise Cascade Page 1 of 2 Reaction Summary (Down /Uplift)(lbs)Bearing Live Dead Snow Wind Roof Live B1,3"942 /0 1653 /0 B2,3-1/2"2402 /0 4227 /0 B3,3-1/2"2402 /0 4227 /0 B4,3"942 /0 1653 /0 Load Summary Live Dead Snow Wind Roof Live Tributary Tag Description Load Type Ref.Start End Loc.100%90%115%160%125% 0 Self-Weight Unf.Lin.(lb/ft)L 00-00-00 21-06-00 Top 11 00-00-00 1 Standard Load Unf.Area (lb/ft²)L 00-00-00 21-06-00 Top 20 35 15-00-00 Controls Summary Value %Allowable Duration Case Location Pos.Moment 3553 ft-lbs 24.6%115%11 18-05-02 Neg.Moment -4266 ft-lbs 29.5%115%13 07-03-00 End Shear 1880 lbs 22.6%115%10 00-10-04 Cont.Shear 2929 lbs 35.2%115%12 15-00-00 Total Load Deflection L/999 (0.093")n\a n\a 11 18-00-12 Live Load Deflection L/999 (0.061")n\a n\a 15 03-05-15 Total Neg.Defl.L/999 (-0.004")n\a n\a 11 13-03-11 Max Defl.0.093"n\a n\a 11 18-00-12 Span /Depth 11.7 Bearing Supports Dim.(LxW)Value %AllowSupport %AllowMember Material B1 Wall/Plate 3"x 5-1/4"2594 lbs n\a 22.0%Unspecified B2 Column 3-1/2"x 5-1/4"6628 lbs n\a 48.1%Unspecified B3 Column 3-1/2"x 5-1/4"6628 lbs n\a 48.1%Unspecified B4 Wall/Plate 3"x 5-1/4"2594 lbs n\a 22.0%Unspecified CautionsForroofmembers with slope (1/4)/12 or less final design must ensure that ponding instability will not occur. For roof members with slope (1/2)/12 or less final design must account for Rain-on-Snow surcharge load. DisclosureUseoftheBoiseCascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy,prior to anyone relying on such output as evidence of suitability for a particular application.The output here is based on building code-accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes.To obtain Installation Guide or ask questions,please call (800)232-0788 before installation. BC CALC®,BC FRAMER®,AJS™, ALLJOIST®,BC RIM BOARD™,BCI®, BOISE GLULAM™,BC FloorValue®, VERSA-LAM®,VERSA-RIM PLUS®, Page 2 of 2 Triple 1-3/4"x 7-1/4"VERSA-LAM®LVL 2.1E 3100 SP RB01 (Roof Drop Beam) BC CALC®Member Report Dry |3 spans |No cant.May 4,2022 12:52:46 Build 8381 Job name:Remodel -Roof Header File name: Address:Description: City,State,Zip:Specifier:Chris N. Customer:Arrow -Red Wing Designer:Anthony Estevez Code reports:ESR-1040 Company:Boise Cascade Page 2 of 2 NotesDesignmeets Code minimum (L/180)Total load deflection criteria. Design meets Code minimum (L/240)Live load deflection criteria. Design meets arbitrary (1")Maximum Total load deflection criteria. Design based on Dry Service Condition. BC CALC®analysis is based on IBC 2009. Calculations assume member is fully braced. Connection Diagram:Full Length of Member a minimum =2"c =2-1/4" b minimum =3"d =24" e minimum =3" Calculated Side Load =0.0 lb/ft Nailing applies to both sides of the member Connectors are:3-1/4 in.Pneumatic Gun Nails