HomeMy WebLinkAboutLA201187-7062 182nd St W Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION
PAGE 2
OFFICE USE ONLY
BUILDING PERMIT TYPE REQUIRED INSPECTIONS
SINGLE FAMILY DWELLING BUILDING
DUPLEX AS BUILT
TOWNHOUSE UNITS BUILDING FINAL
DETACHED TOWN HOUSE UNIT DECK FOOTING
CONDO FIREPLACE
ACESSORY BUILDING FOOTING
REROOF FOUNDATION
RESIDE FRAMING
PORCH FRAMING
GARAGES
INSULATION
RES ADDN/REPAIR/RMDL
DECK
PORCH
GARAGES LATH
LOWER LEVEL FINISH LOWER LEVEL FINAL
ADDITION OTHER
FOUNDATION ONLY PORCH FOOTING
MISCELLANEOUS POURED WALL
DEMO SEPTIC TANK REMOVAL
MOVED SITE
MECHANICAL
CITY BUILDING VALUATION: $AIR TEST
FINAL
BUILDING PERMIT FEES ROUGH-IN
$PERMIT FEE PLUMBING
$PLAN CHECK FINAL
$SURCHARGE ROUGH-IN
$METRO SAC METER SIZE
$CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE
$CITY SEWER HOOKUP UNIT SEWER/WATER
$LANDSCAPE ESCROW SEWER/WATER
$TREE ESCROW FINAL
$MISC ESCROW STREET DRAINTILE
$PLUMBING BUILDING INFORMATION
$MECHANICAL TYPE OF CONSTRUCTION
$SEWER WATER ZONING
$OTHER CODE EDITION
$TOTAL FIRE SUPPRESSION SYSTEM
OCCUPANCY GROUP
APPROVED BY:
BUILDING INSPECTOR: Date:
PLUMBING/MECHANICAL
INSPECTOR: Date:
COMMENTS:
Secure door closed until deck is
constructed with a separate permit.
Concept Approval ONLYSubject to Field Inspection
Inspector Date
2020
MN Bldg
Code
04/20/2022dmathews
BWPs
Above
UFER Ground
-Provide 20' Rebar in footing and stub
up near electrical service panel.
Verify loads with girder
truss specs, may require
removal of top plates at
bearing due to crushing.
5.17' LIB5.17' LIB5.17' LIB
4' WSP
4' WSP
4' WSP
4' WSP
3'
CS-WSP
3'
CS-WSP
BWPs
Above
PFHPFH
4' WSP
4' WSP
4' WSP
8' LIB
8' LIB
8' LIB
8' LIB
2.25' WSP2.25' WSP
-Min. 15" clearance to any
obstruction from center of
W.C., 24" in front(typ).
8' LIB
3' WSP3' WSP
3' WSP
Date Certificate Po
x Passive (No Fan )
Active (With fan and
monometer or other system
monitoring device )
Location (or future location) of Fan:
Other Please Describe Here
x
R-15 x
x
R-20 x x
R-20 x x
19+5 x x
R-49 x
R-49 x
R-38 x
R-38+5 x x
Not applicable, all ducts located in conditioned space
X
x Not required per mech. code
Passive
Powered
Interlocked with exhaust
device.
Input in
BTUS:
66,000 Capacity
in
Gll
Other, describe:
AFUE or
HSPF%
93%
Cfm's
" round duct OR
" metal duct
Not required per mech. code
X Passive
x Low: Other, describe:
Low:
Location of fan(s), describe Cfm's
6 " Flex
" metal duct
Balanced Ventilation capacity in cfms:
Capacity continuous ventilation rate in cfms:
Total ventilation (intermittent + continuous) rate in cfms:
82 High:
Energy Recover Ventilator (ERV) Capacity in cfms High: Location of duct or system:
Below Entire Slab
Foundation Wall
Perimeter of Slab on Grade
Rim Joist (1st Floor)
Rim Joist (2nd Floor+)
Wall
Ceiling, flat
R-5 where required
R10 Rigid Exterior, R10 Int closed cell
R10 Rigid Exterior, R10 Int closed cell
R5 Exterior, R19 Batts
New Construction Energy Code Compliance Certificate
Per R401.3 Certificate. A building certificate shall be posted on or in the electrical
distribution panel.
Mailing Address of the Dwelling or Dwelling Unit City
Lakeville7062 182nd Street
Name of Residential Contractor
MECHANICAL VENTILATION SYSTEM Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces
or air
source heat pump with gas back-up furnace):
Combustion Air Select a Type
Select Type
Heat Recover Ventilator (HRV) Capacity in cfms: 192
MN License Number
Brandl Anderson Homes BC604388
THERMAL ENVELOPE RADON CONTROL SYSTEM
Type: Check All That Apply
Insulation Location
Total R-Value of all Types of InsulationNon or Not ApplicableFiberglass, BlownFiberglass, BattsFoam, Closed CellFoam Open CellMineral FiberboardRigid, Extruded PolystyreneRigid, IsocynurateAttic
Residential Load Calculation
Heating Loss Heating Gain Cooling Load
52393 20978 26,603
13 Location of duct or system:
Rating or Size 50 Output
in
T
2.5
Efficiency
SEER
/EER
Natural Gas Natural Gas Electric
13ACXN030
Fuel Type
Manufacturer Lennox Lennox
Model ML193UH070
Average U-Factor (excludes skylights and one door ) U0.30
Solar Heat Gain Coefficient (SHGC): 0.30 R-value R-8
MECHANICAL SYSTEMS Make-up Air Select a Type
Appliances Heating System
Domestic Water
Heater Cooling System
Duct system air tightness
Heating or Cooling Ducts Outside Conditioned Spaces
Ceiling, vaulted
Bay Windows or cantilevered areas
Floors over unconditioned area
Describe other insulated areas
Building envelope air tightness:
Windows & Doors
000000Builders Associaton of Minnesota version 101014
40,000
X
X
40,000
1408
40,000
3000
3000
1408 3000 .47
.47 .53
40,000
40,000 13.33
13.33 .53 7.1
3.01
NR
240
375
375
3618
542
542
170
85
4/8/22 Y
AM