HomeMy WebLinkAboutLA201420 - Approved Steven Sheehan - ENG CAD-min
76 North Meadowbrook Drive
Scott E. Wyssling, PE Alpine, UT 84004
Jon P. Ward, SE, PE office (201) 874-3483
Gregory T. Elvestad, PE swyssling@wysslingconsulting.com
April 20, 2022
Everlight Solar Construction PO Box 930550
Verona, WI 53593
Roof Material: Composite Asphalt Shingles Roof Slope: 36 degrees
Attic Access: Accessible Foundation: Permanent C. Loading Criteria Used
• Dead Load
o Existing Roofing and framing = 7 psf
o New Solar Panels and Racking = 3 psf
o TOTAL = 10 PSF
• Dead Load
o Existing Roofing and framing = 7 psf
o New Solar Panels and Racking = 3 psf
o TOTAL = 10 psf
• Live Load = 20 psf (reducible) – 0 psf at locations of solar panels
• Ground Snow Load = 50 psf
• Wind Load based on ASCE 7-16
o Ultimate Wind Speed = 115 mph (based on Risk Category II)
o Exposure Category C
Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the Minnesota Residential Code (2018 IRC), including provisions allowing existing structures
to not require strengthening if the new loads do not exceed existing design loads by 105% for gravity elements and 110% for seismic elements. This analysis indicates that the existing framing will support the additional panel loading without damage, if installed correctly.
Re: Engineering ServicesSheehan Residence21267 Ilvista Way, Lakeville MN8.625 kW System
To Whom It May Concern:
We have received information regarding solar panel installation on the roof of the above referencedstructure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability
to support the additional loads imposed by the proposed solar system.
A.Site Assessment Information
1.Site visit documentation identifying attic information including size and spacing of framing
for the existing roof structure.2.Design drawings of the proposed system including a site plan, roof plan and connectiondetails for the solar panels. This information will be utilized for approval and construction
of the proposed system.
B.Description of Structure:
Roof Framing: Prefabricated wood trusses at 24” on center. All truss members areconstructed of 2x4 dimensional lumber.
Page 2 of 2
D. Solar Panel Anchorage
1. The solar panels shall be mounted in accordance with the most recent SolarRoofHook installation manual. If during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. The maximum allowable withdrawal force for a 5/16” lag screw is 235 lbs per inch of penetration as
identified in the National Design Standards (NDS) of timber construction specifications. Based on a minimum penetration depth of 2½”, the allowable capacity per connection is greater than the design withdrawal force (demand). Considering the variable factors for the existing roof framing and installation tolerances, the connection using one 5/16” diameter lag screw with a minimum of
2½” embedment will be adequate and will include a sufficient factor of safety. 3. Considering the wind speed, roof slopes, size and spacing of framing members, and condition of the roof, the panel supports shall be placed no greater than 48” on center. 4. Panel supports connections shall be staggered to distribute load to adjacent framing members.
Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the Minnesota Residential Code (2018 IRC), current industry standards, and is based on
information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me.
Very truly yours,
Scott E. Wyssling, PE Minnesota License No. 57927fe
Signed 4/20/2022
Everlight Solar Construction
7369 Highway 13 W
Savage, MN 55378
License# BC771658
833.786.4387 ext. 701
CONTRACTOR INFORMATION:
SITE INFORMATION
Steven Sheehan
21267 Ilvista Way
Lakeville, MN 55044
AC SYSTEM SIZE: 7.124 kW AC
DC SYSTEM SIZE: 8.625 kW DC
Lat, 44.640986
Long, -93.2566535999999
(25) Mission Solar MSE345SX5T PV MODULES
(13) AP Systems YC600 INVERTER(S)
Dakota Electric
DATE:
April 19, 2022
COVER PAGE - PV01
DRAWN BY: SoloCAD
1.INSTALLATION OF SOLAR PHOTOVOLTAIC SYSTEM SHALL BE IN ACCORDANCE WITH NEC ARTICLE
690, AND ALL OTHER APPLICABLE NEC CODES WHERE NOTED OR EXISTING.
2.PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL
EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.
3. ALL WIRES, INCLUDING THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM
PHYSICAL DAMAGE IN ACCORDANCE WITH NEC ARTICLE 250
4. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE; THIS SYSTEM IS UTILITY INTERACTIVE PER
UL 1741 AND DOES NOT INCLUDE STORAGE BATTERIES OR OTHER ALTERNATIVE STORAGE SOURCES.
5. ALL DC WIRES SHALL BE SIZED ACCORDING TO [NEC 690.8]
6.DC CONDUCTORS SHALL BE WITHIN PROTECTED RACEWAYS IN ACCORDANCE WITH [NEC 690.31]
7. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL JURISDICTIONAL BUILDING CODE.
PHOTOVOLTAIC (PV) SYSTEM SPECIFICATIONS
AERIAL VIEW:
OCCUPANCY: R-3
ZONING: RESIDENTIAL
STREET VIEW:
GENERAL NOTES
APPLICABLE GOVERNING CODES SITE SPECIFICATIONS
2020 NEC
2020 MRC
2020 MFC
2020 MBC
EQUIPMENT:
AC SYSTEM SIZE: 7.124 kW AC
DC SYSTEM SIZE: 8.625 kW DC
(25) Mission Solar MSE345SX5T PV MODULES
(13) AP Systems YC600 INVERTER(S)
RACKING: Quickbolt - 48" O.C.
PV01 COVER PAGE
PV02 SITE PLAN
PV03 ROOF ATTACHMENTS
PV04 MOUNTING DETAIL
PV05 LINE DIAGRAM
PV06 ELECTRICAL CALCS
PV07 LABELS
PV08 PLACARD
PV09 SITE PHOTOS
SHEET INDEX:
Signed 4/20/2022
PVC M
MSP
AC
JB
JB
JB
Everlight Solar Construction
7369 Highway 13 W
Savage, MN 55378
License# BC771658
833.786.4387 ext. 701
CONTRACTOR INFORMATION:
SITE INFORMATION
Steven Sheehan
21267 Ilvista Way
Lakeville, MN 55044
AC SYSTEM SIZE: 7.124 kW AC
DC SYSTEM SIZE: 8.625 kW DC
Lat, 44.640986
Long, -93.2566535999999
(25) Mission Solar MSE345SX5T PV MODULES
(13) AP Systems YC600 INVERTER(S)
Dakota Electric
DATE:
April 19, 202221267 Ilvista WayFRONT OF HOMEVISIBLE, LOCKABLE,
LABELED AC DISCONNECT
LOCATED WITHIN 10'
OF UTILITY METER SITE PLAN - PV02
DRAWN BY: SoloCAD
MP1
MP2
ARRAY DETAILS:
MOUNTING PLANE:AZIMUTH:TILT:
MP1 154°36°
MP2 244° 36°
EQUIPMENT LEGEND:
INVERTERVISIBLE, LOCKABLE, LABELED
AC DISCONNECT
METER SOCKET
(FOR UTILITY PV METER)
UTILITY METER
MAIN SERVICE PANEL LC LOAD CENTER
FIRE ACCESS PATHWAY (3' TYP)
C
INV
PV
AC
MSP
M
COMBINER BOX
PROPERTY LINE
BATT BATTERY(IES)
SUB SUB PANEL
125'-3"50'-3"
73'-8"
125'-0"
Signed 4/20/2022
PVC M
MSP
AC
JB
JB
JB
EQUIPMENT INFORMATION:ROOF INFO: PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA:
RAIL MANUFACTURER:IronRidge ROOF TYPE:Asphalt Shingle PV MODULE COUNT: 25
RAIL PART NUMBER: XR-10 ROOF FRAMING:ARRAY AREA:MODULE COUNT * 19.83 ft² = 495.75
ATTACHMENTS Quickbolt 2x4 ROOF AREA: 2106 ft²
ATTACHMENT QTY:50 24"PERCENT OF ROOF COVERED:24%
SPLICE QTY:8 ATTACHMENT SPACING: 48'' ARRAY WEIGHT: MODULE COUNT * 45 lbs = 1125 lbs
MIDCLAMP QTY:36 DISTRIBUTED LOAD:ARRAY LBS/ATTACHMENTS = 22.5
ENDCLAMP QTY:28 POINT LOAD: (lbs/ft²) (ARRAY) WEIGHT/AREA = 2.27 lbs/ft²
Everlight Solar Construction
7369 Highway 13 W
Savage, MN 55378
License# BC771658
833.786.4387 ext. 701
CONTRACTOR INFORMATION:
SITE INFORMATION
Steven Sheehan
21267 Ilvista Way
Lakeville, MN 55044
AC SYSTEM SIZE: 7.124 kW AC
DC SYSTEM SIZE: 8.625 kW DC
Lat, 44.640986
Long, -93.2566535999999
(25) Mission Solar MSE345SX5T PV MODULES
(13) AP Systems YC600 INVERTER(S)
Dakota Electric
DATE:
April 19, 2022
ROOF ATTACHMENTS - PV03
DRAWN BY: SoloCAD
3'-0" TYP
1'-6" TYP
Signed 4/20/2022
TRUSS/TOP CHORD SIZE:
TRUSS/TOP CHORD SPACING:
TRUSS
RAIL
L-FOOT/ATTACHMENT BRACKET
(E) ROOF FRAMING
QUICKBOLT
FLASHING
PV MODULE
(E) COMP SHINGLE ROOF (1 LAYER)
RAIL
END CLAMP
PV MODULE
MID CLAMP
PV MODULE
4"
2 1
2" MIN.
DEPTH
RAIL
RAIL
FLASHING & QUICKBOLT
2'-8" MIN -
3'-10" MAX
3
RAIL
PV MODULE
" MAX."1'-8"
MAX.
21
FRONT VIEW
10" MIN
- 1'-4"
MAX2'-8" MIN -
3'-10" MAX
10" MIN
- 1'-4"
MAX
SIDE VIEW
(E) RAFTER/TOP CHORDS
(E) RAFTER/TOP CHORD
DETAIL, MOUNTING AND FLASHING
END CLAMP DETAILS MID CLAMP DETAILS
3
21
EQUIPMENT INFORMATION:ROOF INFO: PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA:
RAIL MANUFACTURER:IronRidge ROOF TYPE:Asphalt Shingle PV MODULE COUNT: 25
RAIL PART NUMBER: XR-10 ROOF FRAMING:ARRAY AREA:MODULE COUNT * 19.83 ft² = 495.75
ATTACHMENTS Quickbolt 2x4 ROOF AREA: 2106 ft²
ATTACHMENT QTY:50 24"PERCENT OF ROOF COVERED:24%
SPLICE QTY:8 ATTACHMENT SPACING: 48'' ARRAY WEIGHT: MODULE COUNT * 45 lbs = 1125 lbs
MIDCLAMP QTY:36 DISTRIBUTED LOAD:ARRAY LBS/ATTACHMENTS = 22.5
ENDCLAMP QTY:28 POINT LOAD: (lbs/ft²) (ARRAY) WEIGHT/AREA = 2.27 lbs/ft²
Everlight Solar Construction
7369 Highway 13 W
Savage, MN 55378
License# BC771658
833.786.4387 ext. 701
CONTRACTOR INFORMATION:
SITE INFORMATION
Steven Sheehan
21267 Ilvista Way
Lakeville, MN 55044
AC SYSTEM SIZE: 7.124 kW AC
DC SYSTEM SIZE: 8.625 kW DC
Lat, 44.640986
Long, -93.2566535999999
(25) Mission Solar MSE345SX5T PV MODULES
(13) AP Systems YC600 INVERTER(S)
Dakota Electric
DATE:
April 19, 2022
MOUNTING DETAIL - PV04
DRAWN BY: SoloCAD
Signed 4/20/2022TRUSS
TRUSS/TOP CHORD SIZE:
TRUSS/TOP CHORD SPACING:
J-BOX
STRING (1): 15.96 A AC, 14 MODULES
STRING (2): 13.68 A AC, 11 MODULES
N
G
3
AC COMBINER BOX
SOLAR LOADS ONLYUL 1741 COMPLIANT
AC
DC
AC
DC6 INVERTERS
AC
DC
AC
DC7 INVERTERS
J-BOX
(N) 100A
(2) 20A-2P
J-BOX1 2
1 2
4
(E) LOADS
N
G
(E)GROUNDING
ELECTRODE
SUPPLY SIDE CONNECTION:
NEC 230.46, NEC 230.79,
NEC 705.12(A).
K4977-INT MILBANK
LUG KIT TO BE ADDED
(E) 200A-2P
(E) 200A MAIN SERVICE PANEL
(E)
(E)UTILITY METER
120/240 VAC
TO UTILITY GRID
UTILITY PV PRODUCTION
METER BASE
4 4
(N) 40A FUSES
PV AC DISCONNECT
60A FUSED,
VISIBLE, LOCKABLE,
LABELED, OPEN
240V, 2-POLE
Everlight Solar Construction
7369 Highway 13 W
Savage, MN 55378
License# BC771658
833.786.4387 ext. 701
CONTRACTOR INFORMATION:
SITE INFORMATION
Steven Sheehan
21267 Ilvista Way
Lakeville, MN 55044
AC SYSTEM SIZE: 7.124 kW AC
DC SYSTEM SIZE: 8.625 kW DC
Lat, 44.640986
Long, -93.2566535999999
(25) Mission Solar MSE345SX5T PV MODULES
(13) AP Systems YC600 INVERTER(S)
Dakota Electric
DATE:
April 19, 2022
LINE DIAGRAM - PV05
DRAWN BY: SoloCAD
AP Systems YC600 Specs
MAX INPUT VOLTAGE:55 V
MAX DC SHORT CIRCUIT CURRENT:12 A
MAXIMUM OUTPUT POWER:548 W
MAXIMUM OUTPUT CURRENT:2.28 A
NOM. OUTPUT VOLTAGE:240 V
MAX UNITS PER 20A CIRCUIT:7
1-Phase, 60 HZ, UL 1741 Listed
Mission Solar MSE345SX5T Specs
POWER MAX (PMAX):345W
OPEN CIRCUIT VOLTAGE (VOC):41V
MAX POWER-POINT CURRENT (IMP):10.34A
MAX POWER-POINT VOLTAGE (VMP):33.37V
SHORT CIRCUIT CURRENT (ISC):10.92A
SERIES FUSE RATING:20A
VISIBLE, LOCKABLE,
LABELED AC DISCONNECT
LOCATED WITHIN 10'
OF UTILITY METER
Conduit & Conductor Schedule
TAG QTY WIRE GAUGE DESCRIPTION CONDUIT SIZE
1 (2)12-2 TC-ER, THWN-2, COPPER (L1, L2)N/A - FREE AIR(1)6 AWG THWN-2 COPPER - (GROUND)
2 (2)10 AWG THHN/THWN-2, COPPER - (L1, L2)3/4" EMT(1)10 AWG THWN-2 COPPER - (GROUND)
3 (4)10 AWG THHN/THWN-2, COPPER - (L1, L2)3/4" EMT(1)10 AWG THWN-2 COPPER - (GROUND)
4 (3)6 AWG THWN-2 COPPER - (L1, L2, NEUTRAL)3/4" EMT(1)8 AWG THWN-2 COPPER - (GROUND)
Equipment Schedule
TYPE:QTY:DESCRIPTION:RATING:
MODULES:(25)Mission Solar MSE345SX5T 345 W
INVERTERS:(13)AP Systems YC600 548 W
AC DISCONNECTS:(1)PV AC Disconnect, 240V, 2-Pole 60 A
INTERCONNECTION NOTES
1. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9] & [NEC 230.95]
2. SUPPLY SIDE INTERCONNECTION ACCORDING TO [NEC705.12(A)] WITH SERVICE ENTRANCE CONDUCTORS IN
ACCORDANCE WITH [NEC 240.21(B)]
DISCONNECT NOTES
1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS
REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS)
2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A
VISIBLE-BREAK SWITCH.
3. FUSED AC DISCONNECT TO BE USED.
GROUNDING & GENERAL NOTES:
1. PV INVERTER IS UNGROUNDED, TRANSFORMER-LESS TYPE.
2. DC GEC AND AC EGC TO BE SPLICED TO EXISTING ELECTRODE
3. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO
BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION.
4. JUNCTION BOX QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD -
JUNCTION BOXES DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE
TRANSITIONS.
5. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER
AC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT.
STRING CALCULATIONS
MAX AC CURRENT:
MICRO INVERTERS IN SERIES
NOMINAL STRING VOLTAGE:
MAX AC OUTPUT POWER
ARRAY DC POWER:
TOTAL MAX AC CURRENT:
STRING #1
15.96A
7
240V
3836W
8625W
29.64A
STRING #2
13.68A
6
240V
3288W
AP Systems YC600
Everlight Solar Construction
7369 Highway 13 W
Savage, MN 55378
License# BC771658
833.786.4387 ext. 701
CONTRACTOR INFORMATION:
SITE INFORMATION
Steven Sheehan
21267 Ilvista Way
Lakeville, MN 55044
AC SYSTEM SIZE: 7.124 kW AC
DC SYSTEM SIZE: 8.625 kW DC
Lat, 44.640986
Long, -93.2566535999999
(25) Mission Solar MSE345SX5T PV MODULES
(13) AP Systems YC600 INVERTER(S)
Dakota Electric
DATE:
April 19, 2022
ELECTRICAL CALCS - PV06
DRAWN BY: SoloCAD
Conduit & Conductor Schedule
TAG QTY WIRE GAUGE DESCRIPTION CONDUIT SIZE CONDUCTOR RATING CONDUCTOR TEMP. RATE AMBIENT TEMP TEMP. DERATE # OF CONDUCTORS
DERATE
CONDUCTOR RATING
W/DERATES CONDUIT FILL
1 (2)12-2 TC-ER, THWN-2, COPPER (L1, L2)N/A - FREE AIR 30A 90°C 32°C 0.96 N/A - FREE AIR 28.8A N/A - FREE AIR(1)6 AWG THWN-2 COPPER - (GROUND)
2 (2)10 AWG THHN/THWN-2, COPPER - (L1, L2)3/4" EMT 40A 90°C 32°C 0.96 1 38.4A 11.9%(1)10 AWG THWN-2 COPPER - (GROUND)
3 (4)10 AWG THHN/THWN-2, COPPER - (L1, L2)3/4" EMT 40A 90°C 32°C 0.96 0.8 30.72A 19.8%(1)10 AWG THWN-2 COPPER - (GROUND)
4 (3)6 AWG THWN-2 COPPER - (L1, L2, NEUTRAL)3/4" EMT 65A 75°C 32°C 0.96 1 62.4A 35.5%(1)8 AWG THWN-2 COPPER - (GROUND)
SYSTEM OCPD CALCULATIONS
INVERTER MODEL(S):AP Systems YC600
# OF INVERTERS:13
MAX OUTPUT CURRENT:2.28A
(# OF INVERTERS) X (MAX OUTPUT CURRENT) X 125% <= OCPD RATING
(13 X 2.28A X 1.25) = 37.05A <= 40A, OK
SUPPLY SIDE INTERCONNECTION
MAIN BUSBAR RATING:200A
MAIN DISCONNECT RATING:200A
PV OCPD RATING:40A
SERVICE RATING >= PV OCPD
200A >= 40A, OK, OK
NUMBER OF CURRENT CARRYING CONDUCTORS PERCENT OF VALUES
4-6 .80
7-9 .70
10-20 .50
Everlight Solar Construction
7369 Highway 13 W
Savage, MN 55378
License# BC771658
833.786.4387 ext. 701
CONTRACTOR INFORMATION:
SITE INFORMATION
Steven Sheehan
21267 Ilvista Way
Lakeville, MN 55044
AC SYSTEM SIZE: 7.124 kW AC
DC SYSTEM SIZE: 8.625 kW DC
Lat, 44.640986
Long, -93.2566535999999
(25) Mission Solar MSE345SX5T PV MODULES
(13) AP Systems YC600 INVERTER(S)
Dakota Electric
DATE:
April 19, 2022
LABELS - PV07
DRAWN BY: SoloCAD
LABEL 6
MARKED AT AC DISCONNECTING MEANS.
[NEC 690.54]
LABEL 5
EQUIPMENT CONTAINING OVERCURRENT
DEVICES IN CIRCUITS SUPPLYING POWER TO A
BUSBAR OR CONDUCTOR SUPPLIED FROM
MULTIPLE SOURCES SHALL BE MARKED TO
INDICATE THE PRESENCE OF ALL SOURCES.[NEC
705.12(B)(2)(3)(c)]
LABEL 3
PLACED ADJACENT TO THE BACK-FED BREAKER FROM
THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE
CONNECTION TO BUSBAR.
[NEC 705.12(B)(2)(3)(c)]
*ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS
PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON THE ELECTRICAL DIAGRAM PAGE.
JUNCTION BOX
OR COMBINER BOX
MAIN SERVICE PANEL
AC DISCONNECT
EXISTING SUB PANEL
(IF WHERE POINT OF
INTERCONNECTION
IS MADE)
PV COMBINER
SUBPANEL -
IF USED TO COMBINE
PV OUTPUT CIRCUITS
AC
DC
INVERTER (S)
INTEGRATED DC DISCONNECT
2
8
6
9
5
(ONLY IF PV
INTERCONNECTION
CONSISTS OF LOAD
SIDE BREAKER)
7
1 1
1
5
(ONLY IF PV
INTERCONNECTION
CONSISTS OF LOAD
SIDE BREAKER)
7
3
LABELING DIAGRAM:
LABEL 7
AT DIRECT-CURRENT EXPOSED RACEWAYS, CABLE TRAYS, COVERS AND
ENCLOSURES OF JUNCTION BOXES, AND OTHER WIRING METHODS; SPACED
AT MAXIMUM 10FT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS,
PARTITIONS, CEILINGS, OR FLOORS.
[NEC 690.31(D)(2)]
LABEL 9
SIGN LOCATED ON OR NO MORE THAN 3FT
FROM INITIATION DEVICE
[NEC 690.56(C)(2)].
LABEL 8
FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS
LEAVING THE ARRAY:
SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM
SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE
CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED
RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION.
[NEC 690.56(C)(1)(A)]
LABEL 1
PLACED ON THE MAIN DISCONNECTING MEANS FOR THE PV
SYSTEM.
[NEC 690.13(B)]
LABELING NOTES:
1.LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE
EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE
ADJUSTMENTS.
2.LABELING REQUIREMENTS BASED ON THE 2020 NATIONAL ELECTRIC CODE, OSHA STANDARD
19010.145, ANSI Z535.
3.MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION.
4.LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC
110.21]
5.LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND
PERMANENTLY AFFIXED [IFC 605.11.1.1]
3 4
1
LABEL 4
PLACED ON EQUIPMENT CONTAINING OVERCURRENT
DEVICES IN CIRCUITS SUPPLYING POWER TO
A BUSBAR OR CONDUCTOR SUPPLIED FROM MULTIPLE
SOURCES
[NEC 705.10(C)]
2
3 4
1
LABEL 2
FOR PV DISCONNECTING MEANS WHERE THE LINE AND
LOAD TERMINALS MAY BE ENERGIZED IN THE OPEN
POSITION.
[NEC 690.13(B)]
WARNING!
TERMINALS ON THE LINE AND
LOAD SIDES MAY BE ENERGIZED
IN THE OPEN POSITION
!WARNING
THIS EQUIPMENT IS FED BY MULTIPLE
SOURCES. TOTAL RATING OF ALL
OVERCURRENT DEVICES, EXCLUDING
MAIN SUPPLY OVERCURRENT
DEVICE, SHALL NOT EXCEED
AMPACITY OF BUSBAR.
PHOTOVOLTAIC AC DISCONNECT
RATED AC OUTPUT CURRENT:
NOMINAL OPERATING AC VOLTAGE:
ELECTRIC SHOCK HAZARD
MAIN PHOTOVOLTAIC
SYSTEM DISCONNECT
WARNING!
POWER SOURCE OUTPUT CONNECTION.
DO NOT RELOCATE THIS OVERCURRENT DEVICE.
WARNING!DUAL POWER SOURCE
SECOND SOURCE IS PHOTOVOLTAIC SYSTEM
PHOTOVOLTAIC POWER SOURCE
TURN RAPID SHUTDOWN
SWICH TO THE "OFF"
POSITION TO SHUT DOWN
PV SYSTEM AND REDUCE
SHOCK HAZARD IN ARRAY
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
SOLAR ELECTRIC
PV PANELS
RAPID SHUTDOWN
SWITCH FOR
SOLAR PV SYSTEM
30
240
PVC M
MSP
AC
JB
JB
JB
Everlight Solar Construction
7369 Highway 13 W
Savage, MN 55378
License# BC771658
833.786.4387 ext. 701
CONTRACTOR INFORMATION:
SITE INFORMATION
Steven Sheehan
21267 Ilvista Way
Lakeville, MN 55044
AC SYSTEM SIZE: 7.124 kW AC
DC SYSTEM SIZE: 8.625 kW DC
Lat, 44.640986
Long, -93.2566535999999
(25) Mission Solar MSE345SX5T PV MODULES
(13) AP Systems YC600 INVERTER(S)
Dakota Electric
DATE:
April 19, 2022
POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR
ARRAYS WITH SAFETY DISCONNECTS AS SHOWN:
CAUTION
DIRECTORY
PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE
SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM.
(ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN:
NEC 690.56(B)&(C), [NEC 705.10])
21267 Ilvista Way, Lakeville MN 55044 FRONT OF HOMERAPID SHUTDOWN AC
DISCONNECT SWITCH
PLACARD - PV08
DRAWN BY: SoloCAD
COMBINER
MAIN DISTRIBUTION
UTILITY DISCONNECT
PV ARRAY
SYSTEM UTILIZES MICROINVERTERS LOCATED UNDER EACH MODULE
Everlight Solar Construction
7369 Highway 13 W
Savage, MN 55378
License# BC771658
833.786.4387 ext. 701
CONTRACTOR INFORMATION:
SITE INFORMATION
Steven Sheehan
21267 Ilvista Way
Lakeville, MN 55044
AC SYSTEM SIZE: 7.124 kW AC
DC SYSTEM SIZE: 8.625 kW DC
Lat, 44.640986
Long, -93.2566535999999
(25) Mission Solar MSE345SX5T PV MODULES
(13) AP Systems YC600 INVERTER(S)
Dakota Electric
DATE:
April 19, 2022
SITE PHOTOS:
SITE PHOTOS - PV09
DRAWN BY: SoloCAD
Everlight Solar Construction
7369 Highway 13 W
Savage, MN 55378
License# BC771658
833.786.4387 ext. 701
CONTRACTOR INFORMATION:
SITE INFORMATION
Steven Sheehan
21267 Ilvista Way
Lakeville, MN 55044
AC SYSTEM SIZE: 7.124 kW AC
DC SYSTEM SIZE: 8.625 kW DC
Lat, 44.640986
Long, -93.2566535999999
(25) Mission Solar MSE345SX5T PV MODULES
(13) AP Systems YC600 INVERTER(S)
Dakota Electric
DATE:
April 19, 2022
SITE PHOTOS:
FRONT/BACK VIEWS - PV09.1
DRAWN BY: SoloCAD
Everlight Solar Construction
7369 Highway 13 W
Savage, MN 55378
License# BC771658
833.786.4387 ext. 701
CONTRACTOR INFORMATION:
SITE INFORMATION
Steven Sheehan
21267 Ilvista Way
Lakeville, MN 55044
AC SYSTEM SIZE: 7.124 kW AC
DC SYSTEM SIZE: 8.625 kW DC
Lat, 44.640986
Long, -93.2566535999999
(25) Mission Solar MSE345SX5T PV MODULES
(13) AP Systems YC600 INVERTER(S)
Dakota Electric
DATE:
April 19, 2022
SITE PHOTOS:
SIDE VIEWS - PV09.2
DRAWN BY: SoloCAD
Everlight Solar Construction
7369 Highway 13 W
Savage, MN 55378
License# BC771658
833.786.4387 ext. 701
CONTRACTOR INFORMATION:
SITE INFORMATION
Steven Sheehan
21267 Ilvista Way
Lakeville, MN 55044
AC SYSTEM SIZE: 7.124 kW AC
DC SYSTEM SIZE: 8.625 kW DC
Lat, 44.640986
Long, -93.2566535999999
(25) Mission Solar MSE345SX5T PV MODULES
(13) AP Systems YC600 INVERTER(S)
Dakota Electric
DATE:
April 19, 2022
SITE PHOTOS:
METER/OPEN MSP - PV09.3
DRAWN BY: SoloCAD
THESE SHEETS, DESIGNS, AND SPECS ARE PROPERTY OF SUN INCORPORATED. NO PART SHALL BE DUPLICATED OR USED FOR NONE OTHER THAN ITS SPECIFIC PROJECT WITHOUT WRITTEN CONSENT FROM SUN INCORPORATED.MOUNT SHEETSheet: 5File: \\SUN-SERVER\Sun Incorporated Jobs Master\Equipment\MOUNTS\QUICK MOUNT\QMPV-datasheet-QMHSS-LS-QuickHookSM-web.pdfMissing or invalid referenceSheet: 2File: \\SUN-SERVER\Sun Incorporated Jobs Master\Equipment\MOUNTS\QUICK MOUNT\QMPV-datasheet-QMHSS-LS-QuickHookSM-web.pdfMissing or invalid reference