Loading...
HomeMy WebLinkAboutLA201294 - 16392 Jaffna Place-Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: Passive (No Fan) Active (With fan and monitoring device ) Location (or future location) of Fan: Other Please Describe Here Not applicable, all ducts located in conditioned space Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS: Capacity in Gallons:Other, describe: AFUE or HSPF% Cfm's " round duct OR " metal duct Not required per mech. code Passive Low: Other, describe: Low: Location of fan(s), describe: Cfm's " round duct OR " metal duct Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. New Construction Energy Code Compliance Certificate Name of Residential Contractor MN License Number City Mailing Address of the Dwelling or Dwelling Unit Rigid, Extruded PolystyreneHeat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: Combustion Air Select a Type Location of duct or system: Rim Joist (2nd Floor+) Building envelope air tightness: Below Entire Slab Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area THERMAL ENVELOPE Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM Total R-Value of all Types of InsulationType: Check All That Apply Mineral FiberboardInsulation Location Foam, Closed Cell Describe other insulated areas Ceiling, flat Non or Not ApplicableFiberglass, BlownFiberglass, Batts Foundation Wall Output in Tons: Appliances Cooling System Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Make-up Air Select a Type Domestic Water Heater Model Heating System Rim Joist (1st Floor) Average U-Factor (excludes skylights and one door ) U: Duct system air tightness: Rating or Size Efficiency Heating Gain Cooling Load Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Residential Load Calculation SEER /EER Capacity continuous ventilation rate in cfms: Heating Loss Manufacturer Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Date Cert. Posted R-value MECHANICAL SYSTEMS Builders Associaton of Minnesota version 101014 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Dec-10 06:39:37 Right-Suite® Universal 2021 21.0.08 RSU29636 Page 1 ...5 JAFFNA PLACE - 2625 INT (FAIRFAX) - SOUTH.rup Calc = MJ8 Front Door faces: S 2625 INT (FAIRFAX)Job:Load Short Form 12/9/2021Date:Entire House Energy Diagnostics, Inc.By: Energy Diagnostics, Inc. 405 E Archer Way, Valparaiso, IN 46383 Phone: 219-464-4457 Fax: 219-464-0035 Project Information DR Horton MNFor: 16445 Jaffna Place, Lakeville, MN 55044 Design Information InfiltrationClgHtg Blower doorMethod88-15Outside db (°F) 4 (substantial) / 2Shielding / stories7570Inside db (°F) 50 Pa / 813 cfmPressure / AVF1385Design TD (°F) M-Daily range 5050Inside humidity (%) 3555Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Bryant Make Bryant Trade Bryant Legacy Line 92 Gas Furn... Trade BRYANT HEATING AND COOLING SYS... Model 912SD36040E17 Cond BA13NA024BNG0G AHRI ref 0 Coil CNPVU3017ALA++TDR AHRI ref 201810140 Efficiency 92.1 AFUE Efficiency 10.5 EER, 13 SEER Heating input Btuh40000 Sensible cooling Btuh15820 Heating output Btuh37000 Latent cooling Btuh6780 Temperature rise °F47 Total cooling Btuh22600 Actual air flow cfm745 Actual air flow cfm745 Air flow factor cfm/Btuh0.031 Air flow factor cfm/Btuh0.064 Static pressure in H2O0 Static pressure in H2O0 Space thermostat Load sensible heat ratio 0.77 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) 1/2 BATH 32 71 0 2 0 OWNERS SUITE 202 2274 1106 69 71 LAUNDRY 53 90 515 3 33 BATH 2 86 693 137 21 9 BED 2 150 2356 1182 72 76 OWNERS BATH 132 2735 463 83 30 OWNERS WIC 48 82 45 2 3 BED 3 139 2969 1238 91 79 KITCHEN/MUD RM 214 3084 3412 94 219 GREAT ROOM/FOYER 540 9295 2529 284 162 MECH 55 94 52 3 3 OFFICE 60 102 721 3 46 UPPER HALL 224 571 226 17 15 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Dec-10 06:39:37 Right-Suite® Universal 2021 21.0.08 RSU29636 Page 2 ...5 JAFFNA PLACE - 2625 INT (FAIRFAX) - SOUTH.rup Calc = MJ8 Front Door faces: S Entire House 1935 24418 11624 745 745 Other equip loads 7519 246 Equip. @ 0.93 RSM 11040 Latent cooling 3483 TOTALS 1935 31937 14523 745 745 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Dec-10 06:39:37Right-Suite® Universal 2021 21.0.08 RSU29636 Page 1...5 JAFFNA PLACE - 2625 INT (FAIRFAX) - SOUTH.rup Calc = MJ8 Front Door faces: S 2625 INT (FAIRFAX)Job:Project Summary 12/9/2021Date:Entire House Energy Diagnostics, Inc.By: Energy Diagnostics, Inc. 405 E Archer Way, Valparaiso, IN 46383 Phone: 219-464-4457 Fax: 219-464-0035 Project Information DR Horton MNFor:16445 Jaffna Place, Lakeville, MN 55044 Notes: Design Information Minneapolis, Crystal AP, MN, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F-15 Outside db °F88Inside db °F70 Inside db °F75Design TD °F85 Design TD °F13Daily range MRelative humidity %50Moisture difference gr/lb35 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh24418 Structure Btuh11624Ducts Btuh0 Ducts Btuh0Central vent (SER=64% 49 cfm) Btuh1610 Central vent (SER=64% 49 cfm) 246 BtuhHeat recovery Heat recoveryHumidification Btuh5909 Blower Btuh0Piping Btuh0Equipment load Btuh31937 Use manufacturer's data nRate/swing multiplier 0.93InfiltrationEquipment sensible load Btuh11040 Method Latent Cooling Equipment Load SizingBlower doorShielding / stories 4 (substantial) / 250 Pa / 813 cfmPressure / AVF Structure Btuh2330Ducts Btuh0Central vent (49 cfm) Btuh1154CoolingHeatingHeat recovery19351935Area (ft²) Equipment latent load Btuh34831626916269Volume (ft³)Air changes/hour 0.130.31 Equipment Total Load (Sen+Lat)Btuh14523Equiv. AVF (cfm) 3685 Req. total capacity at 0.70 SHR ton1.3 Heating Equipment Summary Cooling Equipment Summary Make Bryant Make BryantTrade Bryant Legacy Line 92 Gas Furn... Trade BRYANT HEATING AND COOLING SYS...Model 912SD36040E17 Cond BA13NA024BNG0GAHRI ref 0 Coil CNPVU3017ALA++TDRAHRI ref 201810140Efficiency 92.1 AFUE Efficiency 10.5 EER, 13 SEERHeating input Btuh40000 Sensible cooling Btuh15820Heating output Btuh37000 Latent cooling Btuh6780Temperature rise °F47 Total cooling Btuh22600Actual air flow cfm745 Actual air flow cfm745Air flow factor cfm/Btuh0.031 Air flow factor cfm/Btuh0.064Static pressure in H2O0 Static pressure in H2O0Space thermostat Load sensible heat ratio 0.77 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Dec-10 06:39:37 Right-Suite® Universal 2021 21.0.08 RSU29636 Page 1 ...5 JAFFNA PLACE - 2625 INT (FAIRFAX) - SOUTH.rup Calc = MJ8 Front Door faces: S 2625 INT (FAIRFAX)Job:Loads for Multiple Orientations 12/9/2021Date:Entire House Energy Diagnostics, Inc.By: Energy Diagnostics, Inc. 405 E Archer Way, Valparaiso, IN 46383 Phone: 219-464-4457 Fax: 219-464-0035 Project Information DR Horton MNFor: 16445 Jaffna Place, Lakeville, MN 55044 Design Conditions Location: CoolingHeatingIndoor: 7570Indoor temperature (°F)Minneapolis, Crystal AP, MN, US 1385Design TD (°F)ft869Elevation: 5050Relative humidity (%)°N45Latitude: Outdoor:35.554.5Moisture difference (gr/lb)CoolingHeating Infiltration:88-15Dry bulb (°F) )M(20-Daily range (°F) 73-Wet bulb (°F) 7.515.0Wind speed (mph) Front Door North Northeast East Southeast South Southwest West Northwest Sensible Load (Btuh) 11711 13978 13970 12567 11040 12823 13653 13135 Latent Load (Btuh) 3483 3483 3483 3483 3483 3483 3483 3483 Total Load (Btuh) 15194 17461 17453 16051 14523 16306 17136 16618 Heating AVF (cfm) 745 745 745 745 745 745 745 745 Cooling AVF (cfm) 745 745 745 745 745 745 745 745 Building Orientation Cooling Load Total Cooling Load (Btuh)Direction Front Door faces 0 5000 10000 15000 20000 N NE E SE S SW W NW Front Door faces SouthCurrent Orientation: Front Door faces NortheastHighest Cooling Load: 2021-Dec-10 06:39:40 Right-Suite® Universal 2021 21.0.08 RSU29636 Page 1 ...5 JAFFNA PLACE - 2625 INT (FAIRFAX) - SOUTH.rup Calc = MJ8 Front Door faces: S 2625 INT (FAIRFAX)Job:Manual S Compliance Report 12/9/2021Date:Entire House Energy Diagnostics, Inc.By: Energy Diagnostics, Inc. 405 E Archer Way, Valparaiso, IN 46383 Phone: 219-464-4457 Fax: 219-464-0035 Project Information DR Horton MNFor: 16445 Jaffna Place, Lakeville, MN 55044 Cooling Equipment Design Conditions °F75.3Entering coil DB:Btuh11871Sensible gain:°F88.0Outdoor design DB: °F63.0Entering coil WB:Btuh3483Latent gain:°F73.0Outdoor design WB: Btuh15354Total gain:°F75.0Indoor design DB: cfm745Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ACEquipment type: BA13NA024BNG0G+CNPVU3017ALA++TDRModel:BryantManufacturer: cfm745Actual airflow: % of load151Btuh17936Sensible capacity: % of load123Btuh4299Latent capacity: %81SHR:% of load145Btuh22234Total capacity: Heating Equipment Design Conditions °F67.9Entering coil DB:Btuh31937Heat loss:°F-15Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Gas furnaceEquipment type: 912SD36040E17Model:BryantManufacturer: cfm745Actual airflow: °F50Temp. rise:% of load116Btuh37000Output capacity: Meets all requirements of ACCA Manual S. 2021-Dec-10 06:39:40 Right-Suite® Universal 2021 21.0.08 RSU29636 Page 1 ...5 JAFFNA PLACE - 2625 INT (FAIRFAX) - SOUTH.rup Calc = MJ8 Front Door faces: S 2625 INT (FAIRFAX)Job:Parts Order 12/9/2021Date: Energy Diagnostics, Inc.By: Energy Diagnostics, Inc. 405 E Archer Way, Valparaiso, IN 46383 Phone: 219-464-4457 Fax: 219-464-0035 BILL TO: SHIP TO: Attn: Attn: Phone: Phone: Fax: Fax: Notes: Ship viaDate requiredPurchase order #Ordered byOrder date ExtensionDiscUnit listTotalQtyDescriptionPart #Src pricepieces Rheia Duct System Equipment RHEA 000895.08953-in Duct Uninsulated10-00-190 RHEA 00098.098.03-in ferrule10-01-010 RHEA 00038.038.0Duct board Take Off Inside10-01-040 RHEA 00038.038.0Duct board Take Off Outside10-01-050 RHEA 00014.014.0Ceiling Boot Assembly10-01-220 RHEA 00014.014.0Ceiling Diffuser Assembly10-04-230 RHEA 00052.052.0Hanger Bar Assembly00-00-240 RHEA 00018.018.0Elbow Extension10-01-020 RHEA 00024.024.0High Sidewall Boot Assembly10-01-200 RHEA 00024.024.0Slotted Diffuser10-04-090 RHEA 00011.011.0Coupler10-01-030 0Subtotal, Rheia Duct System Equipment Duct System Equipment WSF 4.3004.301.01.0Round metal duct, D = 13"DDMt13 PGM 20.80020.801.01.0Plenum round take off, size 13"FPLG-13 WSF 81.0004.5018.018.0Round metal duct, D = 14"DDMt14 PGM 28.00028.001.01.0Round smooth elbow, size 14"FDELS-14 WSF 0001.01.0Return boot from round duct, size 14"FBTO-14 WSF 0001.01.0Plenum side round take off with trans, size 14"FPLJ-14 WSF 0001.01.0Rectangular metal floor two way grill, 12"x12"FRGRMFT-1212 134.10Subtotal, Duct System Equipment 134.10Overall total 2021-Dec-10 06:39:40 Right-Suite® Universal 2021 21.0.08 RSU29636 Page 2 ...5 JAFFNA PLACE - 2625 INT (FAIRFAX) - SOUTH.rup Calc = MJ8 Front Door faces: S 2021-Dec-10 06:39:40 Right-Suite® Universal 2021 21.0.08 RSU29636 Page 1 ...5 JAFFNA PLACE - 2625 INT (FAIRFAX) - SOUTH.rup Calc = MJ8 Front Door faces: S 2625 INT (FAIRFAX)Job:Parts Pull Order 12/9/2021Date: Energy Diagnostics, Inc.By: Energy Diagnostics, Inc. 405 E Archer Way, Valparaiso, IN 46383 Phone: 219-464-4457 Fax: 219-464-0035 BILL TO: SHIP TO: Attn: Attn: Phone: Phone: Fax: Fax: Notes: Ship viaDate requiredPurchase order #Ordered byOrder date QtyQtyTotalQtyDescriptionPart #Src returnedissuedpieces Rheia Duct System Equipment RHEA 8958953-in Duct Uninsulated10-00-190 RHEA 98.0983-in ferrule10-01-010 RHEA 38.038Duct board Take Off Inside10-01-040 RHEA 38.038Duct board Take Off Outside10-01-050 RHEA 14.014Ceiling Boot Assembly10-01-220 RHEA 14.014Ceiling Diffuser Assembly10-04-230 RHEA 52.052Hanger Bar Assembly00-00-240 RHEA 18.018Elbow Extension10-01-020 RHEA 24.024High Sidewall Boot Assembly10-01-200 RHEA 24.024Slotted Diffuser10-04-090 RHEA 11.011Coupler10-01-030 Duct System Equipment WSF 1.01.0Round metal duct, D = 13"DDMt13 PGM 1.01.0Plenum round take off, size 13"FPLG-13 WSF 18.018Round metal duct, D = 14"DDMt14 PGM 1.01.0Round smooth elbow, size 14"FDELS-14 WSF 1.01.0Return boot from round duct, size 14"FBTO-14 WSF 1.01.0Plenum side round take off with trans, size 14"FPLJ-14 WSF 1.01.0Rectangular metal floor two way grill, 12"x12"FRGRMFT-1212 2021-Dec-10 06:39:40 Right-Suite® Universal 2021 21.0.08 RSU29636 Page 1 ...5 JAFFNA PLACE - 2625 INT (FAIRFAX) - SOUTH.rup Calc = MJ8 Front Door faces: S 2625 INT (FAIRFAX)Job:Duct System Summary 12/9/2021Date:Entire House Energy Diagnostics, Inc.By: Energy Diagnostics, Inc. 405 E Archer Way, Valparaiso, IN 46383 Phone: 219-464-4457 Fax: 219-464-0035 Project Information DR Horton MNFor: 16445 Jaffna Place, Lakeville, MN 55044 System Totals 0.120Coil pressure loss (in H2O)HeatingDesign mode 0.123Supply duct pressure loss (in H2O) 0.194Return system pressure loss (in H2O)745Total design airflow (cfm) 0.436Total system pressure loss (in H2O)745Total actual airflow (cfm) Room Details AVF DiffAct AVFDsn AVFHtg AVFClg AVFHtg LoadClg LoadRoom Name (%)(cfm)(cfm)(cfm)(cfm)(Btuh)(Btuh) 31992207101/2 BATH 37269697122741106OWNERS SUITE 2359333390515LAUNDRY 12121219693137BATH 2 17272727623561182BED 2 -12738383302735463OWNERS BATH 27492238245OWNERS WIC -207291917929691238BED 3 498949421930843412KITCHEN/MUD RM -826128428416292952529GREAT ROOM/FOYER 233103339452MECH 498193346102721OFFICE 719171715571226UPPER HALL 2021-Dec-10 06:39:40 Right-Suite® Universal 2021 21.0.08 RSU29636 Page 2 ...5 JAFFNA PLACE - 2625 INT (FAIRFAX) - SOUTH.rup Calc = MJ8 Front Door faces: S Supply Run Details LengthDamp PosVelocityDiamAct AVFDsn AVFReturnTrunkRun Name (ft)(fpm)(in)(cfm)(cfm) 315172392rb1dmn11/2 BATH-A 22140232121rb1dmn1BATH 2-A 48133331818rb1dmn1BED 2 45134031818rb1dmn1BED 2-A 42134931918rb1dmn1BED 2-B 45134131818rb1dmn1BED 2-C 46133931823rb1dmn1BED 3 44134431823rb1dmn1BED 3-A 49132931723rb1dmn1BED 3-B 41135331923rb1dmn1BED 3-C 4163133432rb1dmn1GREAT ROOM/FOYER-A 7161433332rb1dmn1GREAT ROOM/FOYER-B 12155232932rb1dmn1GREAT ROOM/FOYER-C 17149732632rb1dmn1GREAT ROOM/FOYER-D 12150932732rb1dmn1GREAT ROOM/FOYER-E 7155432932rb1dmn1GREAT ROOM/FOYER-F 25143232332rb1dmn1GREAT ROOM/FOYER-G 17149632632rb1dmn1GREAT ROOM/FOYER-H 10163333432rb1dmn1GREAT ROOM/FOYER-I 13423731316rb1dmn1KITCHEN/MUD RM-C 18334031816rb1dmn1KITCHEN/MUD RM-E 29330031616rb1dmn1KITCHEN/MUD RM-G 21333631816rb1dmn1KITCHEN/MUD RM-H 22331431716rb1dmn1KITCHEN/MUD RM-I 29331731716rb1dmn1KITCHEN/MUD RM-K 205174393rb1dmn1LAUNDRY-A 951803103rb1dmn1MECH 175175392rb1dmn1OFFICE-A 145177392rb1dmn1OFFICE-B 13145732428rb1dmn1OWNERS BATH 18147532528rb1dmn1OWNERS BATH-A 14145032428rb1dmn1OWNERS BATH-B 21332031717rb1dmn1OWNERS SUITE-A 18332531717rb1dmn1OWNERS SUITE-B 22331831717rb1dmn1OWNERS SUITE-C 16238932117rb1dmn1OWNERS SUITE-D 185176392rb1dmn1OWNERS WIC-A 41135231917rb1dmn1UPPER HALL Supply Trunk Details TrunkLengthDuctH x WDiamVelocClgHtgName (ft)Material(in)(in)(fpm)(cfm)(cfm) st10ShtMetl24x1212372745745dmn1 1ShtMetl0x013808745745st1 2021-Dec-10 06:39:40 Right-Suite® Universal 2021 21.0.08 RSU29636 Page 3 ...5 JAFFNA PLACE - 2625 INT (FAIRFAX) - SOUTH.rup Calc = MJ8 Front Door faces: S Return Branch Details TrunkDuctStud/JoistH x WDiamVelocTELClgHtgGrilleName MatlOpening (in)(in)(in)(fpm)(in)(cfm)(cfm)Size (in) ShMt0x014697887457450x0rb1 Job #: 2625 INT (FAIRFAX) Performed by Energy Diagnostics, Inc. for: DR Horton MN 16445 Jaffna PlaceLakeville, MN 55044 Energy Diagnostics, Inc. 405 E Archer WayValparaiso, IN 46383 Phone: 219-464-4457 Fax: 219-464-0035 Scale: 1 : 93 Page 1Right-Suite® Universal 2021 21.0.08 RSU296362021-Dec-10 06:40:08 ...- 2625 INT (FAIRFAX) - SOUTH.rup N MAIN KITCHEN/MUD RM 1/2 BATHMAIN RIGHT UNIT GREAT ROOM/FOYER MAIN LEFT UNIT 1/2 BATH-A 9 cfm3.1 " Ceiling Round rb1745 cfm 12 " Insulated duct OR air barrer and insulation need forduct routes of bed 2/3 GREAT ROOM/FOYER-F29 cfm 3.1 " Ceiling Round GREAT ROOM/FOYER-A34 cfm 3.1 " Ceiling Round GREAT ROOM/FOYER-B 33 cfm3.1 " Ceiling Round GREAT ROOM/FOYER-C29 cfm 3.1 " Ceiling Round GREAT ROOM/FOYER-D26 cfm 3.1 " Ceiling Round GREAT ROOM/FOYER-E27 cfm 3.1 " Ceiling Round KITCHEN/MUD RM-G16 cfm 3.1 " Sidewall Slot KITCHEN/MUD RM-H18 cfm 3.1 " Ceiling Round KITCHEN/MUD RM-I17 cfm 3.1 " Sidewall Slot KITCHEN/MUD RM-C 13 cfm3.1 " Ceiling Round KITCHEN/MUD RM-E 18 cfm3.1 " Ceiling Round GREAT ROOM/FOYER-G 23 cfm 3.1 " Ceiling Round GREAT ROOM/FOYER-H 26 cfm3.1 " Ceiling Round GREAT ROOM/FOYER-I 34 cfm3.1 " Ceiling Round KITCHEN/MUD RM-K 17 cfm3.1 " Ceiling Round Job #: 2625 INT (FAIRFAX) Performed by Energy Diagnostics, Inc. for: DR Horton MN 16445 Jaffna PlaceLakeville, MN 55044 Energy Diagnostics, Inc. 405 E Archer WayValparaiso, IN 46383 Phone: 219-464-4457 Fax: 219-464-0035 Scale: 1 : 93 Page 2Right-Suite® Universal 2021 21.0.08 RSU296362021-Dec-10 06:40:08 ...- 2625 INT (FAIRFAX) - SOUTH.rup N UPPER OWNERS SUITE LAUNDRY BATH 2 BED 3 BED 2 OWNERS BATH OWNERS WIC UPPPER RIGHT UNIT MECH OFFICE UPPER HALL UPPER LEFT UNIT OWNERS WIC-A 9 cfm3.1 " Sidewall Slot OWNERS BATH-A 25 cfm3.1 " Sidewall Slot OWNERS BATH 24 cfm3.1 " Sidewall Slot MECH 10 cfm 3.1 " Sidewall Slot OWNERS SUITE-B17 cfm 3.1 " Sidewall Slot LAUNDRY-A9 cfm 3.1 " Sidewall Slot OWNERS SUITE-A17 cfm 3.1 " Sidewall Slot OWNERS SUITE-C 17 cfm3.1 " Sidewall Slot UPPER HALL 19 cfm3.1 " Sidewall Slot BED 3-A18 cfm 3.1 " Sidewall Slot BED 318 cfm 3.1 " Sidewall Slot BED 218 cfm 3.1 " Sidewall Slot BED 3-B17 cfm 3.1 " Sidewall Slot BATH 2-A 21 cfm3.1 " Sidewall Slot DOWNFLOW FURNACE BED 3-C19 cfm 3.1 " Sidewall Slot OFFICE-A 9 cfm 3.1 " Sidewall Slot OFFICE-B 9 cfm3.1 " Sidewall Slot OWNERS BATH-B24 cfm 3.1 " Sidewall Slot Furnace:912SD36040E17 Coil: CNPVU3017ALA OWNERS SUITE-D 21 cfm3.1 " Sidewall Slot BED 2-A 18 cfm 3.1 " Sidewall Slot BED 2-B19 cfm 3.1 " Sidewall Slot BED 2-C18 cfm 3.1 " Sidewall Slot