Loading...
HomeMy WebLinkAbout18119 Jurel CirRECEIVED By Lucas Ritchie at 11:33 am, Apr 26, 2022 CITY OF LAKEVILLE CERTIFICATION OF GRADING AND FINAL PLACEMENT OF IRON MONUMENTS Building Permit #: 175022 Legal Description: Lot 10 Block 1 Subdivision: KENWOOD HILLS 2ND ADDITION Address: 18119 Jurel Circle We -F hereby certify that on 19th day of April , 2022 an inspection of this property was conducted by me or under my direct supervision and that the as -built grades, elevations and drainage patterns of the site and building are in conformance with the grading plan approved by the City Engineer or amendments previously approved by the City Engineer. In addition, all property corner monuments are in place as of this date. Exceptions noted. I hereby certify that this survey, plan or report was prepared by me or under my direct supervision and that I am a duly Licensed Land Surveyor under the laws of the State of Minnesota. Print Name: �i9P .ter _1 Hawkinson 9 Si nature: / c 0/ter Date: April 20, 2022 MN License #: 42299 NOTE: ATTACH A COPY OF THE CERTIFICATE OF SURVEY SHOWING ALL AS - BUILT GRADES, ELEVATIONS AND DRAINAGE PATTERNS Approved subdivision grading plans should be obtained from the property owner or developer. General questions relating to the building permit should be directed to the Building Inspections Department at 952-985-4440. Questions relating to grading should be directed to the Engineering Department at 952-985-4500. Prior to release of the Grading Security, this document shall be filed with: City of Lakeville Engineering Department 20195 Holyoke Avenue Lakeville, MN 55044 11x17 1072 0 /1072 1072.E \ / N. 10724 705 rej 1'� -4- x 1069.7 X 1067.1 1070 2 ±1)068 2 i` 0 1067 6 Zx x 1069.8 Lot area =3965 SF House area =2120 SF Porch area =60 SF Sidewalk area =23 SF Driveway area =98 SF Total Impervious Area =2301 SF Impervious Coverage =58.0% ec e//7a9e \ 2 �e o� L.5 1081 3 1080.3) 1079.0 /EAST X 10800 i07 5 1078.1 X 1077 6 1078.1 1073.4 073 8 Sodded X 1072 9 1072 107 1073 9 x1073 0 to 5.0 1073 6 10738 0 073.0 a 1073.3 -� 10731 1071.4 10724 1068.0 1069 6T 1070 9 1072 3 1076.4 1079 9 „ 1072.E x 1074 4 X X 1068.3 1070.1 1079.8 1081 6 074.5 1081 5 / 1078.2 �1081. 74 5 / 33 TOM L EAST 1073 3 1076 4 x 1075 8 • Denotes iron pipe Denotes service ▪ Denotes television box III Denotes electric box O Denotes telephone box X 000.00 Denotes existing elevation ( 000 00 ) Denotes proposed elevation Denotes drainage flow direction • Denotes spike X 1080 9 66 2> ...A 1080.6 68.80 it 1081 5 O / -r 49.9 lob 3 1080.2 1080 8 X 1081 7 X 1081 5 1082 0 2/8 4) cn 0 0 0 1082. 10 X 1081.8 1083 2 6 1083 1081 4 1081 1 X� 1081.4 N \00 (JI 1081.9 1082 3 1083.0 2.6 X 1082.1 ro N 178361.29 E. 508524.26 1082;6 11082 6 / 083., ., 082. / 1082 5 1082 6 1082.6 1082.3 1081 6 1.63.0 _X33.3 082 1083 10809 tc 1080.9 tc 1081 3 ')0 1081 3 tc Detail not to scale x 1081.4 1082.1 T 0 0 1080 8 1080 8 1081.2 x --".-sr(1080-8) 10821 X 1081 4 80.00 Existing House Sodded 3.Oo Construction Notes 1. Install rock construction entrance. 2 Install silt fence as needed for erosion control 3. Sidewalks shall drain away from house a minimum of 1.0%. 4 Contractor must verify driveway design. 5. Contractor must verify service elevation prior to construction. 6 Add or remove foundation ledge as required General Notes: 1. Grading plan by Loucks last dated 8/5/16 was used to determine proposed elevations shown herein. 2. This survey does not purport to show improvements or encroachments, except as shown, as surveyed by me or under my direct supervision. 3. Proposed building dimensions shown are for horizontal location of structures on the lot only. Contact builder prior to construction for approved construction plans. 4 No specific soils investigation has been performed on this lot by the surveyor. The suitability of soils to support the specific house proposed is not the responsibility of the surveyor. 5. This certificate does not purport to show easements other than those shown on the recorded plat. 6. Bearings shown are based on an assumed datum. PItNEERneenngi P.A. CIVn. ENGINEERS LAND PLANNERS LAND SURVEYORS LANDSCAPE ARCHITECTS 2422 Enterprise Dave Ph. : (651) 681-1914 Mendota Heights, MN 55120 Fax: (651) 681-9488 www.ptoneereng corn Project # .116284031 (Folder #:8025I Drawn by MTW $ © Pioneer Engineering REVISED 4/19/22 IuoI 0 Lowest 1082 4 tob X 1081.7 1081.7 X 1081 2 1080.8 1080.6 X 1080 4 floor elevation House elevations Lowest Floor Elevation Top 0f Foundation Garage Slab Elev 1080.0 tc 8 X 1081.0 > tc1079 per grading plan 1074.0 (Proposed) / As -built : (1074.0) / : (1083.3) / 1083.6 ® Door : (1082.9) / 1083.2 Elev. GRADING AS -BUILT We hereby certify to JMS Custom Homes that this survey, plan or report was prepared by me or under my direct supervision, and that I am a duly licensed Land Surveyor under the laws of the State of Minnesota, dated 09/20/19. Signed: BY: ress- srlal Land Surveyor Minnesota License No. 42299 email-phawkinson@pioneereng.com eer Engineering, P A Lot 10, Block 1, KENWOOD HILLS 2ND ADDITION according to the recorded plat thereof Dakota County, Minnesota Address: 18119 Jurel Circle, Lakeville, Minnesota House Model: Chadwick Elevation: B Buyer: Mundy 1081.3 tc 1081 0 tcbe 0 0 NJ Ln I.L 1080 6 \ U tcbe WIX N Z 0' 10' 20' 111 Scale. 1" = 20' Benchmark Top Nut Hydrant Lot 12 Block 1 Elevation = 1080.39 Revisions 1) 09-25-19 Stake house 2) 04-19-22 Grading As -built Certificate of Survey for: JMS Custom Homes 6035 Culligan Way Minnetonka, MN 55345 (952) 949-3630 1r