HomeMy WebLinkAboutLA200989-5861 178th St W Permit PackRESIDENTIAL BUILDING
PERMIT APPLICATION
CITY OF LAKEVILLE
BUILDING INSPECTIONS DEPARTMENT
20195 HOLYOKE AVENUE
LAKEVILLE, MN 55044
952-985-4440
Office Use Only
__________________
Permit Number
___________________
Received By
___________________
Date Received
_______ ________
Fee Total
SITE ADDRESS:
MAILING ADDRESS: CITY: STATE: ZIP:
JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________
LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________
ESTIMATED VALUATION: PROPOSED START DATE: END DATE:
(New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION:
APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL
NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED)
PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License)
RESIDENT OWNER
NAME:_______________________________________________________________________________
HOME PHONE #:_____________________________ CELL PHONE:___________________________
GENERAL CONTRACTOR
Homeowner
Contractor
CONTRACTOR:_______________________________________________________________________
LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE)
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
PLUMBING WORK
Homeowner
Contractor
CONTRACTOR:__________________________________________LICENSE #: PM______________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
MECHANICAL WORK
Homeowner
Contractor
CONTRACTOR:________________________________________ _______________________________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
BOND #:_______________________________________ EXPIRATION DATE____________________
SEWER/WATER CONTRACTOR
New Construction Only
NAME:________________________________________________ ______________________________
HOME PHONE _____________________________ CELL PHONE:______________________________
BOND #:_______________________________________ EXPIRATION DATE____________________
INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE
ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY
APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND
ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND
WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START
WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN.
NAME OF APPLICANT (Please Print)DATE
APPLICANT’S SIGNATURE:
www.lakevillemn.gov
3/31/22
DM
RESIDENTIAL BUILDING PERMIT APPLICATION
PAGE 2
OFFICE USE ONLY
BUILDING PERMIT TYPE REQUIRED INSPECTIONS
SINGLE FAMILY DWELLING BUILDING
DUPLEX AS BUILT
TOWNHOUSE UNITS BUILDING FINAL
DETACHED TOWN HOUSE UNIT DECK FOOTING
CONDO FIREPLACE
ACESSORY BUILDING FOOTING
REROOF FOUNDATION
RESIDE FRAMING
PORCH FRAMING
GARAGES
INSULATION
RES ADDN/REPAIR/RMDL
DECK
PORCH
GARAGES LATH
LOWER LEVEL FINISH LOWER LEVEL FINAL
ADDITION OTHER
FOUNDATION ONLY PORCH FOOTING
MISCELLANEOUS POURED WALL
DEMO SEPTIC TANK REMOVAL
MOVED SITE
MECHANICAL
CITY BUILDING VALUATION: $AIR TEST
FINAL
BUILDING PERMIT FEES ROUGH-IN
$PERMIT FEE PLUMBING
$PLAN CHECK FINAL
$SURCHARGE ROUGH-IN
$METRO SAC METER SIZE
$CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE
$CITY SEWER HOOKUP UNIT SEWER/WATER
$LANDSCAPE ESCROW SEWER/WATER
$TREE ESCROW FINAL
$MISC ESCROW STREET DRAINTILE
$PLUMBING BUILDING INFORMATION
$MECHANICAL TYPE OF CONSTRUCTION
$SEWER WATER ZONING
$OTHER CODE EDITION
$TOTAL FIRE SUPPRESSION SYSTEM
OCCUPANCY GROUP
APPROVED BY:
BUILDING INSPECTOR: Date:
PLUMBING/MECHANICAL
INSPECTOR: Date:
COMMENTS:
MAIN FLOOR1' -8 1/4"UPPER PLATE20' -5 1/4"T.O. FOUNDATION0' -0"T.O. FOUNDATION0' -0"MAIN PLATE10' -9 3/8"MAIN PLATE10' -9 3/8"UPPER FLOOR12' -4 1/8"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"UPPER FLOOR PLATE HEIGHT8' - 1 1/8"ALUMINUM SOFFIT& FASCIA TYP.6" SMARTSIDEFRIEZE BOARD TYP.VINYL BOARD &BATTEN TYP.VINYL LAP SIDING & VINYL CORNERS ALL SIDESCULTURED STONE W/CONCRETE CAP4" SMARTSIDE TRIM@ WINDOWS & DOORSTYP. -FRONT ONLYADDRESS STONE6" SMARTSIDE STORYBOARD TYP.4' - 0"42424 AWN FIXEDR.O. 2' -0" x 2' -0"H.H. 2' -6"SEE COLUMN DETAIL SHEET A-5017" / 12"4" / 12"7" / 12"8" 12"GARAGE PLATE HEIGHT10' - 9 3/8"3' - 6"8" 12"1/4" = 1'-0"A-2011FRONT ELEVATIONTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:3/31/2022 10:58:50 AMPAYTON XL MODELL10, B1 - KNOB HILL 2ND ADD'N5861 178TH STREET WESTLAKEVILLE, MN 55044A-201OTT2943.31.22 CB110610847942.24.22 CB8'-1 1/8"9'-1 1/8"8'-4" POUR2984THE PAYTON XLSHEET INDEXSHEET NAME SHEET NUMBERELEVATION A-201ELEVATIONS A-202FOUNDATION PLAN A-401LOWER FLOOR A-402MAIN FLOOR A-403UPPER FLOOR A-404ROOF/ WINDOW SCHEDULE A-501DETAILS A-502Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode04/12/2022dmathews
24" RETURNSTYPICAL7" 12"7" 12"7" / 12"8" / 12"8" / 12"8" / 12"ALUMINUM SOFFIT& FASCIA TYP.VINYL SIDING& CORNERS @SIDES & REAR7" / 12"7" 12"4" 12"8" 12"24" RETURNSTYPICAL7" 12"7" 12"4" 12"7" / 12"8" / 12"8" / 12"4:12STANDARD ENERGY HEELS @ 7:12W/ 8:12 TO MATCH FASCIA LINE18" OVERHANGS & 12" RAKES TYP.6 ROOF VENTS @ HOUSE4 ROOF VENTS @ GARAGE7" / 12"7" / 12"8" / 12"8" / 12"7" / 12"8" / 12"8" / 12"8" / 12"8" / 12"7" / 12"7" / 12"4" / 12"4" / 12"STANDARD ENERGY HEELS @ 4:12 W/7:12 & 8:12 TO MATCH FASCIA LINESTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:3/31/2022 10:58:52 AMPAYTON XL MODELL10, B1 - KNOB HILL 2ND ADD'N5861 178TH STREET WESTLAKEVILLE, MN 55044A-202OTT2943.31.22 CB110610847942.24.22 CB8'-1 1/8"9'-1 1/8"8'-4" POUR2984THE PAYTON XL1/8" = 1'-0"A-2021LEFT ELEVATION1/8" = 1'-0"A-2022REAR ELEVATION1/8" = 1'-0"A-2023RIGHT ELEVATION1/8" = 1'-0"A-2024ROOF PLANSecure door closed until deck isconstructed with a separate permit.
48' - 0"1' - 10"19' - 10"20' - 2"11' - 0"18' - 10"31' - 2"50' - 0"28' - 2"19' - 10"14' - 0"5' - 10"3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 10"(W) POUREDCONCRETE FOUND. WALL W/4" x 8" EXTERIOR LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE19' - 8"20' - 4"*ALL DIMENSIONS ARE TO OUTSIDE OF CONCRETE48' - 0"15' - 8 1/4"3' - 4 1/2"3' - 11 1/4"3' - 10 3/4"13' - 1 1/4"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.25' - 6"22' - 6"40' - 0"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.0' - 4"26' - 4"16' - 6"11' - 8"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.2' - 0"20' - 6"1' - 11 1/2"16' - 3" M.O.1' - 11 1/2"1' - 1 1/2"8' - 3" M.O.1' - 7 1/2"7'-8"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.40' - 0"10' - 0"3' - 11"7' - 4"0' - 5"14' - 8"LEAVE A 12" GAP IN FOOTINGFOR PLUMBING:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODESTEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE50' - 0"14' - 6 1/4"11' - 9"8' - 5 1/2"5' - 3 1/4"36" x 36" x 12" CONCRETE FTG.W/ (3) #5 REBAR EACH WAYSTEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY0' - 4"7' - 0 3/4"12' - 7 1/4"30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAYTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:3/31/2022 10:58:52 AMPAYTON XL MODELL10, B1 - KNOB HILL 2ND ADD'N5861 178TH STREET WESTLAKEVILLE, MN 55044A-401OTT2943.31.22 CB110610847942.24.22 CB8'-1 1/8"9'-1 1/8"8'-4" POUR2984THE PAYTON XL1/4" = 1'-0"A-4011FOUNDATION PLANUFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel.
UP 16RUNEXCAVATEDFURNACESUMPW. H.F. D.4' VANITYFAMILY ROOMBEDROOM #5BATH25' - 6"22' - 6"1' - 10"19' - 10"20' - 2"11' - 0"18' - 10"31' - 2"28' - 2"19' - 10"15' - 10"5' - 10"4' - 8"CO DET.SMOKEDET.18" FLOOR TRUSSESPER MFG. SPACING19' - 3 1/2"3' - 8 1/2"3' - 8 1/2"13' - 3 1/2"22/4 x 6/8R.O. 2' -6" x 6' -11"48" F.G. SHWRCLOSET32/6 x 6/8R.O. 2' -8" x 6' -11"18" FLOOR TRUSSESPER MFG. SPACING14' - 0"5' - 10"11' - 8"16' - 6"UNEXCAVATED10' - 0"40' - 0" (BRACED WALL LINE SPACING)R & SH.2x67' - 7"1' - 11"3' - 8"SMOKEDET.*3-1/2" CONC. FLOOR*MECHANICALS MAY VARY19' - 8"20' - 4"*ALL DIMENSIONS ARE TO OUTSIDE OF CONCRETE/SHEATHING2-2x10 W/2 TRIMMERS2-2x102-2x102-2x102-9 1/2" LSL@ 65"12" CANTILEVERABOVE50' - 0"40' - 0"4' - 3 1/4"7' - 4 3/4"3' - 11"10' - 9"0' - 4"14' - 8"11' - 8"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.4' - 2 1/2"15' - 1"3' - 6"52/8 x 6/8R.O. 2' -10" x 6' -11"MECHANICAL22/4 x 6/8R.O. 2' -6" x 6' -11"AIR EX.2" FOAM INSULATIONBETWEEN WALL & SLAB1' - 11 1/2"16' - 3" M.O.1' - 11 1/2"1' - 1 1/2"8' - 3" M.O.1' - 7 1/2"2' - 0"20' - 6"26' - 4"48' - 0"48' - 0"6' - 9"11' - 0"12' - 9"9' - 6"86048 SLR.O. 5' -0" x 4' -0"H.H. 6' -10"124-48-2448 SLR.O. 8' -0" x 4' -0"H.H. 6' -10"32/6 x 6/8R.O. 2' -8" x 6' -11"50' - 0"STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.106/0 x 6/8 SLIDERR.O. 6' -0" x 6' -8"2-9 1/2" LSL2-9 1/2" LSL3-9 1/2" LVL W/3 TRIMMERS3-2x6CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.15'-6" OF WALL BRACINGREQUIRED. BRACE TO FOUNDATIONOR UNTIL MINIMUM IS MET28' - 0" (BRACED WALL LINE SPACING)15'-6" OF WALL BRACINGREQUIRED. BRACE TO FOUNDATIONOR UNTIL MINIMUM IS MET0' - 4"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES3 TRIMMERS 1/4" = 1'-0"A-4021LOWER FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:3/31/2022 10:58:53 AMPAYTON XL MODELL10, B1 - KNOB HILL 2ND ADD'N5861 178TH STREET WESTLAKEVILLE, MN 55044A-402OTT2943.31.22 CB110610847942.24.22 CB8'-1 1/8"9'-1 1/8"8'-4" POUR2984THE PAYTON XLFANBWPsAbove
UP 17RDN 16RDN 3RDN 3R22' - 6"25' - 6"28' - 0"20' - 0"50' - 0"3/0 x 6/8 W/12" D.S. SL'S8KITCHENDINING ROOMGREAT ROOMFOYEROFFICEDW30" RANGEGARAGEPORCH1212" TRANSOM / 6/0 x 6/8SLIDER5' - 11"5' - 0"17' - 1"6' - 0"14' - 0"18' - 10"31' - 2"20' - 2"11' - 0"9' - 6"12' - 6"11' - 3"6' - 9"50' - 0"2' - 1"16' - 0"2' - 1"1' - 3"8' - 0"1' - 9"0' - 10"5' - 2"1' - 0"11' - 0"7' - 4"SMOKEDET.2-11 7/8" LSL4' - 2"4' - 0"12" CANT. ABOVE3' - 10"9' - 0"6' - 6"SEE COLUMN DETAIL SHEET A-5014' - 4"5' - 10"0' - 10"15' - 0"18" FLOOR TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSES@ 24" O.C.3-2x10 W/2 TRIMMERS2-9 1/2" LSL W/3 TRIMMERS2-2x10TYP.0' - 4 1/2"20' - 6"2' - 0"62/8 x 6/8 FIRE RATEDR.O. 2' -10" x 6' -10 1/4"2-2x1210' - 0"40' - 0"SNACK BAR19' - 4"20' - 8"4' - 0"1' - 4"CS-WSP3' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.SINKSET FIREPLACE @ F.F.HALF HIGH STONE WRAPPED TO EXTERIOR WALL W/ WRAPPED MANTELPOWDER36" REF22/4 x 6/8R.O. 2' -6" x 6' -11"3/0 x 6/8OPG.72-2x102-2x10 W/2 TRIMMERS2-2X102-11 7/8"LSL FLUSH W/3 TRIMMERS2-2x10 W/2 TRIMMERS2-2x102-2X102-2X10CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP5' - 0" B.W.P.2-2X1048' - 0"7' - 5"18' - 7"3' - 2 3/4"5' - 6"3' - 2"1' - 0"3' - 9"2' - 0"3' - 4"4' - 2 1/4"12' - 8 3/4"12' - 2"19' - 8"3' - 8"4' - 6"11' - 6"16' - 6"19' - 3 1/2"3' - 8 1/2"3' - 8 1/2"13' - 3 1/2"2-2102-9 1/2" LSL24" CANTILEVER ABOVE26' - 0"9' - 8"11' - 0"40' - 0"KNEE WALL W/14" SPINDLES2-2x102-11 7/8"LSL FLUSH W/3 TRIMMERS2-11 7/8"LSL FLUSHW/ 2 TRIMMERS5/0 x 6/8OPG.99" HEAT DUCT2' - 0"2' - 0"14' - 3"2' - 10"3' - 1"2' - 10"EQEQ11P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"11P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"11P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"74242 SLR.O. 3' -6" x 3' -6"H.H. 7' -2"63618 PICR.O. 3' -0" x 1' -6"H.H. 8' -0"63618 PICR.O. 3' -0" x 1' -6"H.H. 8' -0"107260 SLR.O. 6' -0" x 5' -0"H.H. 6' -10"32424 AWNR.O. 2' -0" x 2' -0"H.H. 6' -10"ATTICACCESSR & SH.CS-WSP4' - 0" B.W.P.16" SH.16" SH.PAINTED CABINETSFULL TILE BACKSPLASH12/0 x 6/8R.O. 2' -2" x 6' -11"16' x 8' O.H.GARAGEDOOR138' x 8' O.H.GARAGEDOOR1148' - 0"CS-WSP5' - 0" B.W.P.22/4 x 6/8R.O. 2' -6" x 6' -11"CLOSETPED. SINK4' - 6"2' - 6"4' - 4"GAS LINE FOR RANGE1' - 0"GAS F.P.2' - 0"11' - 4"14' - 8"18" FLOOR TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSES@ 24" O.C.MUD ROOMFRAME BOTTOM OFWINDOW @ 44" A.F.F.3-2x6HHUS48LUS4142-2x63-2x62-2x64" CONCRETE SLAB, SLOPETOWARDS DOORS5/8" TYPE X GYP. BD. ALL COMMONWALLS & CEILINGGARAGE PLATE HEIGHT TO MATCHMAIN FLOOR UNLESS NOTED OTHERWISEPFH1' - 9"PFH2' - 1"PFH2' - 1"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES1/4" = 1'-0"A-4031MAIN FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:3/31/2022 10:58:54 AMPAYTON XL MODELL10, B1 - KNOB HILL 2ND ADD'N5861 178TH STREET WESTLAKEVILLE, MN 55044A-403OTT2943.31.22 CB110610847942.24.22 CB8'-1 1/8"9'-1 1/8"8'-4" POUR2984THE PAYTON XLBWPsAboveBWPsAboveFAN
DN 17RBEDROOM #4LAUNDRYBEDROOM #3OWNER'S SUITEHALL1/2 WALL W/WOOD CAPSMOKEDET.SMOKEDET.6' VANITYCLOSETR & SH.32/6 x 6/8R.O. 2' -8" x 6' -11"SMOKEDET.R & SH.BEDROOM #2GIRDER TRUSSCO DET.SMOKEDET.MFG. ROOF TRUSSESPER MFG. SPACINGATTICACCESS2' LINEN32/6 x 6/8R.O. 2' -8" x 6' -11"42/6 x 6/8 PKTR.O. 5' -2" x 6' -11"4:124:12GIRDERTRUSS13' - 0"27' - 0"3' - 0"28' - 0"29' - 0"2' - 0"26' - 6"13' - 6"R & SH.22/4 x 6/8R.O. 2' -6" x 6' -11"22/4 x 6/8R.O. 2' -6" x 6' -11"6' - 4"14' - 6"5' - 8"6' - 9"6' - 9"32/6 x 6/8R.O. 2' -8" x 6' -11"CLOSETBATH2x63' VANITYR & SH.22/4 x 6/8R.O. 2' -6" x 6' -11"0' - 6"22/4 x 6/8R.O. 2' -6" x 6' -11"6' - 6"6' - 6"2' - 6"7' - 6"17' - 0"VAULT LINE2-2x10 W/2 TRIMMERS2-2x102-2x102-2x102-2x10CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.40' - 0"5' - 9"22' - 3"31' - 0"31' - 0"40' - 0"8' - 0"5' - 5"4' - 3"1' - 8"4' - 8"5' - 0"8' - 5"2' - 6"1' - 9 1/2"0' - 9 1/2"14' - 6"9' - 2"3' - 6"2' - 6"11' - 8 1/4"3' - 5 1/2"3' - 1"6' - 7 1/4"19' - 3 1/2"3' - 8 1/2"3' - 8 1/2"13' - 3 1/2"4' - 4"5' - 0"0' - 10"15' - 10"48" F.G.SHOWER W/ C.T. WALLS& BY-PASSDOORS@ 65"@ 65"@ 65"@ 65"2-2x102-2x10 W/2 TRIMMERS52424-2 FIXEDR.O. 4' -0" x 2' -0"H.H. 6' -10"32424 AWNR.O. 2' -0" x 2' -0"H.H. 6' -10"32424 AWNR.O. 2' -0" x 2' -0"H.H. 6' -10"96060 SLR.O. 5' -0" x 5' -0"H.H. 6' -10"86048 SLR.O. 5' -0" x 4' -0"H.H. 6' -10"86048 SLR.O. 5' -0" x 4' -0"H.H. 6' -10"224-48-2460 SLR.O. 8' -0" x 5' -0"H.H. 6' -10"5' TUB/SHWRSMOKEDET.WASHERDRYERDBL FRAMED FOR PLUMBING WALL3' x 5' TUB W/ TILEDECKKNEE WALL W/14" SPINDLESMFG. ROOF TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSESPER MFG. SPACINGEN SUITE52/8 x 6/8R.O. 2' -10" x 6' -11"32/6 x 6/8R.O. 2' -8" x 6' -11"32/6 x 6/8R.O. 2' -8" x 6' -11"2-2x63-2x63-2x63-2x63-2x6THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:3/31/2022 10:58:54 AMPAYTON XL MODELL10, B1 - KNOB HILL 2ND ADD'N5861 178TH STREET WESTLAKEVILLE, MN 55044A-404OTT2943.31.22 CB110610847942.24.22 CB8'-1 1/8"9'-1 1/8"8'-4" POUR2984THE PAYTON XL1/4" = 1'-0"A-4041UPPER FLOOR PLANCS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTESFANFAN-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).
WATCH DOG WATER PROOF COATINGFROM FOOTING TOSILL SEALER6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETRT'D 2x8 SILL PLATEW/ CLOSED CELL ROLLSILL SEALERGRADEGRANULAR FILL4" DRAIN TILEW/ SILT SOCK1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOORLOWER PLATE HEIGHT8' - 2"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.VERIFY FLOOR SYSTEMWITH FLOOR PLANSUPPER FLOOR PLATE HEIGHT8' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.3/4" T&GSUBFLOOR6 MIL. V.B.2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.1/2" OSBSHEATHINGTYVEK (OR EQUAL)ROLL HOUSE WRAPSIDING, VERIFYW/ ELEVATIONS5/8" GYP. BD.5/8" GYP. BD.VENTED ALUMINUMSOFFIT PANELSICE & WATER GUARDFROM EAVE TO 2'-0"MIN. OVER STRUCTUREVENT CHUTES & WIND WASH@ EACH TRUSS SPACEASPHALT SHINGLES W/15# ROLL FELT UNDER1/2" OSB ROOF SHEATHINGMFG. ROOFTRUSSES @ 24" O.C.ATTIC VENTINGAS PER CODER-49 MIN. BLOWNATTIC INSULATIONALUMINUM FASCIA W/2x6 SUB FASCIAALUMINUMDRIP EDGERIM JOISTRIM JOISTR-20 MIN. SPRAYFOAM INSULATION,COVER FOUNDATION WALLGMX THERMAL DRAINAGE BOARD(R-10) INSULATIONDRYVIT INSULATIONPROTECTION FROM SIDINGTO 6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITH OUTSIDE OF SHEATINGR-20 MIN. SPRAYFOAM INSULATION1' - 5"0' - 9 1/2"2x4 @ BOTTOM1x3 TYP.2x22x4 @ TOPSMOOTH LPSMARTSIDE TYP.SOFFIT1' - 9 1/2"1' - 0"FRONTSIDETOP VIEW1' - 5"0' - 9 1/2"FRAMING4x4 POSTTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:3/31/2022 10:58:55 AMPAYTON XL MODELL10, B1 - KNOB HILL 2ND ADD'N5861 178TH STREET WESTLAKEVILLE, MN 55044A-501OTT2943.31.22 CB110610847942.24.22 CB8'-1 1/8"9'-1 1/8"8'-4" POUR2984THE PAYTON XL3" MIN. ABS OR PVC GASTIGHTPIPE FROM SUBSLAB TOMIN. 12" ABOVE ROOF, MUSTBE RUN THRU CONDITIONED SPACE.PIPE CAN BE CONNECTED TOSUMP SYSTEM OR HAVE"T" FITTING (MIN. 10'-0" EA. WAY)IN GRAVEL UNDER SLAB.END OF PIPE MUST BE MIN. 10'-0"AWAY FROM ANY WINDOW OROTHER OPENING THAT IS LESSTHAN 2'-0" BELOW END OF PIPE. END OF PIPE MUST ALSO BEMIN. 10'-0" AWAY FROM ANYWINDOW OR OTHER OPENING INADJOINING OR ADJACENTBUILDINGS.SUFFICIENT SPACE MUST BELEFT AROUND PIPE IN ATTIC SPACETO ADD FAN. SPACE MUST BEMIN. ∅24" CENTERED ON AXIS OFPIPE W/ MIN. 3'-0" VERTICAL SPACE.A SINGLE PIPE CAN BE USED IF ALLSOIL GASES IN DWELLING CANFLOW FREELY BETWEEN ALL LEVELSOF FOUNDATION. THIS INCLUDESINTERIOR FOOTINGS & OTHERBARRIERS IF AIRFLOW HASBEEN ESTABLISHED.LABEL THE VENT PIPE AT LEASTONCE PER FLOOR AND INACCESSIBLE ATTICS WITH"RADON REDUCTION SYSTEM".ONE ELECTRICAL RECEPTACLE ISREQUIRED IN THE ATTIC NEARTHE VENT PIPE FOR OPT. FAN.:PASSIVE RADON SYSTEM:3/8" = 1'-0"A-5012TYP. WALL SECTIONWINDOW SCHEDULETYPE MARK MANUFACTURER MODEL COUNT UNIT ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT1 WINDSOR NEXT DIMENSION 1 24-48-2448 SL 8' - 0" 4' - 0" 6' - 10"2 WINDSOR NEXT DIMENSION 1 24-48-2460 SL 8' - 0" 5' - 0" 6' - 10"3 WINDSOR NEXT DIMENSION 3 2424 AWN 2' - 0" 2' - 0" 6' - 10"4 WINDSOR NEXT DIMENSION 1 2424 AWN FIXED 2' - 0" 2' - 0"2' - 6"5 WINDSOR NEXT DIMENSION 1 2424-2 FIXED 4' - 0" 2' - 0" 6' - 10"6 WINDSOR NEXT DIMENSION 2 3618 PIC 3' - 0" 1' - 6" 8' - 0"7 WINDSOR NEXT DIMENSION 1 4242 SL 3' - 6" 3' - 6" 7' - 2"8 WINDSOR NEXT DIMENSION 3 6048 SL 5' - 0" 4' - 0" 6' - 10"9 WINDSOR NEXT DIMENSION 1 6060 SL 5' - 0" 5' - 0" 6' - 10"10 WINDSOR NEXT DIMENSION 1 7260 SL 6' - 0" 5' - 0" 6' - 10"11 WINDSOR NEXT DIMENSION 3 P4260/A24 T 3' - 6" 7' - 0" 8' - 0"1/2" = 1'-0"A-5013TYP. COLUMNROOM FINISHED SCHEDULEFLOOR ROOM NAME FLOOR AREA PLATE HEIGHT COMMENTSLOWER FLOOR FAMILY ROOM CARPET 431 SF 8' - 2" .LOWER FLOOR BEDROOM #5 CARPET 153 SF 8' - 2" .LOWER FLOOR CLOSET CARPET 65 SF 8' - 2" .LOWER FLOOR STAIRWAY CARPET 66 SF 8' - 2"LOWER FLOOR MECHANICAL CONCRETE 182 SF 8' - 2" FINISH PER CODELOWER FLOOR BATH VINYL 48 SF 8' - 2" .MAIN FLOOR GREAT ROOM CARPET 244 SF 9' - 1 1/8" .MAIN FLOOR OFFICE CARPET 122 SF 9' - 1 1/8" .MAIN FLOOR STAIRWAY CARPET 77 SF 9' - 1 1/8"MAIN FLOOR GARAGE CONCRETE 627 SF 10' - 9 3/8"MAIN FLOOR PORCH CONCRETE 113 SF 9' - 1 1/8" .MAIN FLOOR MUD ROOM VINYL 48 SF 9' - 1 1/8" .MAIN FLOOR POWDER VINYL 30 SF 9' - 1 1/8" .MAIN FLOOR CLOSET VINYL 31 SF 9' - 1 1/8" .MAIN FLOOR KITCHEN WOOD 191 SF 9' - 1 1/8" .MAIN FLOOR DINING ROOM WOOD 110 SF 9' - 1 1/8" .MAIN FLOOR FOYER WOOD 118 SF 9' - 1 1/8" .UPPER FLOOR BEDROOM #4 CARPET 143 SF 8' - 1 1/8" .UPPER FLOOR BEDROOM #3 CARPET 139 SF 8' - 1 1/8" .UPPER FLOOR OWNER'S SUITE CARPET 182 SF 8' - 1 1/8" VAULTEDUPPER FLOOR HALL CARPET 77 SF 8' - 1 1/8" .UPPER FLOOR BEDROOM #2 CARPET 133 SF 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 56 SF 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 27 SF 8' - 1 1/8" .UPPER FLOOR EN SUITE L.V.T. 89 SF 8' - 1 1/8" .UPPER FLOOR LAUNDRY VINYL 30 SF 8' - 1 1/8" .UPPER FLOOR BATH VINYL 43 SF 8' - 1 1/8" .DOOR SCHEDULETYPE MARK DOOR SIZE ROUGH WIDTH ROUGH HEIGHT COUNT COMMENTS1 2/0 x 6/8 2' - 2" 6' - 11" 12 2/4 x 6/8 2' - 6" 6' - 11" 83 2/6 x 6/8 2' - 8" 6' - 11" 74 2/6 x 6/8 PKT 5' - 2" 6' - 11" 15 2/8 x 6/8 2' - 10" 6' - 11" 26 2/8 x 6/8 FIRE RATED 2' - 10" 6' - 10 1/4" 17 3/0 x 6/8 OPG. 18 3/0 x 6/8 W/ 12" D.S. SL'S 19 5/0 x 6/8 OPG. 110 6/0 x 6/8 SLIDER 6' - 0" 6' - 8" 111 8' x 8' O.H. GARAGE DOOR 112 12" TRANSOM / 6/0 x 6/8 SLIDER 113 16' x 8' O.H. GARAGE DOOR 1
6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"5000 PSI CONCRETE@ ALL FOOTINGS2" FOAMBOARD(R-10) INSULATION4" DRAIN TILEW/ SILT SOCKWATER PROOF COATING FROM FOOTING TOSILL SEALERANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" OSBSHEATHINGRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESTOOP, FLASH AS REQ'DAT HOUSE WALLPOUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERSIDING, VERIFYW/ ELEVATIONSTYVEK (OR EQUAL) ROLL HOUSE WRAP0' - 2"FROM SHEATHING TOOUTSIDE OF FOUNDATIONANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLAN3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION5/8" TYPE 'X' GYP BOARD,TAPE & MUD ALL SEAMSRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESLAB, FLASH AS REQ'DAT HOUSE WALL0' - 4"POUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALER0' - 8"FASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP.MIN. 3/8" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).MIN. 1000 LB HOLD-DOWNDEVICE (EMBEDDED INTOCONCRETE & NAILEDINTO FRAMING)FRONT ELEVATIONMIN. FOOTING SIZE UNDER OPENING IS12" X 12". A TURNED DOWN SLAB SHALLBE PERMITTED AT DOOR OPENINGS.MIN. (1) 5/8" DIA. ANCHOR BOLDINSTALLED PER R403.1.6 W/2" X 2" X 3/16" PLATE WASHER.MIN. REINFORCING OF FOUNDATION,ONE #4 BAR TOP & BOTTOM OFFOOTING. LAP BARS 15" MINIMUM.MIN. (2) 4200 LB STRAP-TYPE HOLD-DOWNS (EMBEDDED INTO CONCRETEAND NAILED INTO FRAMING)MIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 3/8" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INALL FRAMING (STUDS, BLOCKING AND SILLS) TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED9' - 11 1/4" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTAL2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.TRT'D SILL PLATEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSSLEEVE EVERY10'-0" MIN.6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODE5000 PSI CONCRETE@ ALL FOOTINGSWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESINSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONDRYVIT INSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITHOUTSIDE OF SHEATHINGTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:3/31/2022 10:58:56 AMPAYTON XL MODELL10, B1 - KNOB HILL 2ND ADD'N5861 178TH STREET WESTLAKEVILLE, MN 55044A-502OTT2943.31.22 CB110610847942.24.22 CB8'-1 1/8"9'-1 1/8"8'-4" POUR2984THE PAYTON XL1/2" = 1'-0"A-5021TYP. WALKOUT SECTION1/2" = 1'-0"A-5022TYP. HOUSE/STOOP WALL1/2" = 1'-0"A-5023TYP. HOUSE/GARAGE WALL3/8" = 1'-0"A-5024METHOD PFH - PORTAL FRAME WITH HOLD-DOWNS1/2" = 1'-0"A-5025BEARING WALL SECTION1/2" = 1'-0"A-5026TYP. LOOKOUT SECTION
MAIN FLOOR1' -8 1/4"UPPER PLATE20' -5 1/4"T.O. FOUNDATION0' -0"T.O. FOUNDATION0' -0"MAIN PLATE10' -9 3/8"MAIN PLATE10' -9 3/8"UPPER FLOOR12' -4 1/8"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"UPPER FLOOR PLATE HEIGHT8' - 1 1/8"ALUMINUM SOFFIT& FASCIA TYP.6" SMARTSIDEFRIEZE BOARD TYP.VINYL BOARD &BATTEN TYP.VINYL LAP SIDING & VINYL CORNERS ALL SIDESCULTURED STONE W/CONCRETE CAP4" SMARTSIDE TRIM@ WINDOWS & DOORSTYP. -FRONT ONLYADDRESS STONE6" SMARTSIDE STORYBOARD TYP.4' - 0"42424 AWN FIXEDR.O. 2' -0" x 2' -0"H.H. 2' -6"SEE COLUMN DETAIL SHEET A-5017" / 12"4" / 12"7" / 12"8" 12"GARAGE PLATE HEIGHT10' - 9 3/8"3' - 6"8" 12"1/4" = 1'-0"A-2011FRONT ELEVATIONTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:2/24/2022 5:11:42 PMPAYTON XL MODELL10, B1 - KNOB HILL 2ND ADD'N5861 178TH STREET WESTLAKEVILLE, MN 55044A-201OTT294110610847942.24.22 CB8'-1 1/8"9'-1 1/8"8'-4" POUR2984THE PAYTON XLSHEET INDEXSHEET NAME SHEET NUMBERELEVATION A-201ELEVATIONS A-202FOUNDATION PLAN A-401LOWER FLOOR A-402MAIN FLOOR A-403UPPER FLOOR A-404ROOF/ WINDOW SCHEDULE A-501DETAILS A-502
24" RETURNSTYPICAL7" 12"7" 12"7" / 12"8" / 12"8" / 12"8" / 12"ALUMINUM SOFFIT& FASCIA TYP.VINYL SIDING& CORNERS @SIDES & REAR7" / 12"7" 12"4" 12"8" 12"24" RETURNSTYPICAL7" 12"7" 12"4" 12"7" / 12"8" / 12"8" / 12"4:12STANDARD ENERGY HEELS @ 7:12W/ 8:12 TO MATCH FASCIA LINE18" OVERHANGS & 12" RAKES TYP.6 ROOF VENTS @ HOUSE4 ROOF VENTS @ GARAGE7" / 12"7" / 12"8" / 12"8" / 12"7" / 12"8" / 12"8" / 12"8" / 12"8" / 12"7" / 12"7" / 12"4" / 12"4" / 12"STANDARD ENERGY HEELS @ 4:12 W/7:12 & 8:12 TO MATCH FASCIA LINESTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:2/24/2022 5:11:43 PMPAYTON XL MODELL10, B1 - KNOB HILL 2ND ADD'N5861 178TH STREET WESTLAKEVILLE, MN 55044A-202OTT294110610847942.24.22 CB8'-1 1/8"9'-1 1/8"8'-4" POUR2984THE PAYTON XL1/8" = 1'-0"A-2021LEFT ELEVATION1/8" = 1'-0"A-2022REAR ELEVATION1/8" = 1'-0"A-2023RIGHT ELEVATION1/8" = 1'-0"A-2024ROOF PLAN
48' - 0"1' - 10"19' - 10"20' - 2"11' - 0"18' - 10"31' - 2"50' - 0"28' - 2"19' - 10"14' - 0"5' - 10"3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 10"(W) POUREDCONCRETE FOUND. WALL W/4" x 8" EXTERIOR LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE19' - 8"20' - 4"*ALL DIMENSIONS ARE TO OUTSIDE OF CONCRETE48' - 0"15' - 8 1/4"3' - 4 1/2"3' - 11 1/4"3' - 10 3/4"13' - 1 1/4"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.25' - 6"22' - 6"40' - 0"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.0' - 4"26' - 4"16' - 6"11' - 8"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.2' - 0"20' - 6"1' - 11 1/2"16' - 3" M.O.1' - 11 1/2"1' - 1 1/2"8' - 3" M.O.1' - 7 1/2"7'-8"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.40' - 0"10' - 0"3' - 11"7' - 4"0' - 5"14' - 8"LEAVE A 12" GAP IN FOOTINGFOR PLUMBING:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODESTEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE50' - 0"13' - 2 3/4"13' - 0 1/2"8' - 5 1/2"5' - 3 1/4"30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAYSTEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY0' - 4"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:2/24/2022 5:11:43 PMPAYTON XL MODELL10, B1 - KNOB HILL 2ND ADD'N5861 178TH STREET WESTLAKEVILLE, MN 55044A-401OTT294110610847942.24.22 CB8'-1 1/8"9'-1 1/8"8'-4" POUR2984THE PAYTON XL1/4" = 1'-0"A-4011FOUNDATION PLAN
UP 16RUNEXCAVATEDFURNACESUMPW. H.F. D.4' VANITYFAMILY ROOMBEDROOM #5BATH25' - 6"22' - 6"1' - 10"19' - 10"20' - 2"11' - 0"18' - 10"31' - 2"28' - 2"19' - 10"15' - 10"5' - 10"4' - 8"CO DET.SMOKEDET.18" FLOOR TRUSSESPER MFG. SPACING19' - 3 1/2"3' - 8 1/2"3' - 8 1/2"13' - 3 1/2"22/4 x 6/8R.O. 2' -6" x 6' -11"48" F.G. SHWRCLOSET32/6 x 6/8R.O. 2' -8" x 6' -11"18" FLOOR TRUSSESPER MFG. SPACING14' - 0"5' - 10"11' - 8"16' - 6"UNEXCAVATED10' - 0"40' - 0" (BRACED WALL LINE SPACING)R & SH.2x67' - 7"1' - 11"3' - 8"SMOKEDET.*3-1/2" CONC. FLOOR*MECHANICALS MAY VARY19' - 8"20' - 4"*ALL DIMENSIONS ARE TO OUTSIDE OF CONCRETE/SHEATHING2-2x10 W/2 TRIMMERS2-2x102-2x102-2x102-9 1/2" LSL@ 65"12" CANTILEVERABOVE50' - 0"40' - 0"4' - 3 1/4"7' - 4 3/4"3' - 11"10' - 9"0' - 4"14' - 8"11' - 8"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.4' - 2 1/2"15' - 1"3' - 6"52/8 x 6/8R.O. 2' -10" x 6' -11"MECHANICAL22/4 x 6/8R.O. 2' -6" x 6' -11"AIR EX.2" FOAM INSULATIONBETWEEN WALL & SLAB1' - 11 1/2"16' - 3" M.O.1' - 11 1/2"1' - 1 1/2"8' - 3" M.O.1' - 7 1/2"2' - 0"20' - 6"26' - 4"48' - 0"48' - 0"6' - 9"11' - 0"12' - 9"9' - 6"86048 SLR.O. 5' -0" x 4' -0"H.H. 6' -10"124-48-2448 SLR.O. 8' -0" x 4' -0"H.H. 6' -10"32/6 x 6/8R.O. 2' -8" x 6' -11"50' - 0"STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.106/0 x 6/8 SLIDERR.O. 6' -0" x 6' -8"2-9 1/2" LSL2-9 1/2" LSL3-9 1/2" LVL W/3 TRIMMERS3-2x6CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.15'-6" OF WALL BRACINGREQUIRED. BRACE TO FOUNDATIONOR UNTIL MINIMUM IS MET28' - 0" (BRACED WALL LINE SPACING)15'-6" OF WALL BRACINGREQUIRED. BRACE TO FOUNDATIONOR UNTIL MINIMUM IS MET0' - 4"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES1/4" = 1'-0"A-4021LOWER FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:2/24/2022 5:11:44 PMPAYTON XL MODELL10, B1 - KNOB HILL 2ND ADD'N5861 178TH STREET WESTLAKEVILLE, MN 55044A-402OTT294110610847942.24.22 CB8'-1 1/8"9'-1 1/8"8'-4" POUR2984THE PAYTON XLHeader Spans:Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ***3 Trimmers
UP 17RDN 16RDN 3RDN 3R22' - 6"25' - 6"28' - 0"20' - 0"50' - 0"3/0 x 6/8 W/12" D.S. SL'S8KITCHENDINING ROOMGREAT ROOMFOYEROFFICEDW30" RANGEGARAGEPORCH1212" TRANSOM / 6/0 x 6/8SLIDER5' - 11"5' - 0"17' - 1"6' - 0"14' - 0"18' - 10"31' - 2"20' - 2"11' - 0"9' - 6"12' - 6"11' - 3"6' - 9"50' - 0"2' - 1"16' - 0"2' - 1"1' - 3"8' - 0"1' - 9"0' - 10"5' - 2"1' - 0"11' - 0"7' - 4"SMOKEDET.2-11 7/8" LSL4' - 2"4' - 0"12" CANT. ABOVE3' - 10"9' - 0"6' - 6"SEE COLUMN DETAIL SHEET A-5014' - 4"5' - 10"0' - 10"15' - 0"18" FLOOR TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSES@ 24" O.C.3-2x10 W/2 TRIMMERS2-9 1/2" LSL W/3 TRIMMERS2-2x10TYP.0' - 4 1/2"20' - 6"2' - 0"62/8 x 6/8 FIRE RATEDR.O. 2' -10" x 6' -10 1/4"2-2x1210' - 0"40' - 0"SNACK BAR19' - 4"20' - 8"4' - 0"1' - 4"PORTAL FRAME W/ HOLD DOWNCS-WSP3' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.SINKSET FIREPLACE @ F.F.HALF HIGH STONE WRAPPED TO EXTERIOR WALL W/ WRAPPED MANTELPOWDER36" REF22/4 x 6/8R.O. 2' -6" x 6' -11"3/0 x 6/8OPG.72-2X102-2X10 W/2 TRIMMERS2-2X102-11 7/8"LSL FLUSH W/3 TRIMMERS2-2X10 W/2 TRIMMERSPORTAL FRAME W/ HOLD DOWN2-2X102-2X102-2X10CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP5' - 0" B.W.P.2-2X1048' - 0"7' - 5"18' - 7"3' - 2 3/4"5' - 6"3' - 2"1' - 0"3' - 9"2' - 0"3' - 4"4' - 2 1/4"12' - 8 3/4"12' - 2"19' - 8"3' - 8"4' - 6"11' - 6"16' - 6"19' - 3 1/2"3' - 8 1/2"3' - 8 1/2"13' - 3 1/2"2-2X102-9 1/2" LSL24" CANTILEVER ABOVE26' - 0"9' - 8"11' - 0"40' - 0"KNEE WALL W/14" SPINDLES2-2X102-11 7/8"LSL FLUSH W/3 TRIMMERS2-11 7/8"LSL FLUSHW/ 2 TRIMMERS5/0 x 6/8OPG.99" HEAT DUCT2' - 0"2' - 0"14' - 3"2' - 10"3' - 1"2' - 10"EQEQ11P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"11P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"11P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"74242 SLR.O. 3' -6" x 3' -6"H.H. 7' -2"63618 PICR.O. 3' -0" x 1' -6"H.H. 8' -0"63618 PICR.O. 3' -0" x 1' -6"H.H. 8' -0"107260 SLR.O. 6' -0" x 5' -0"H.H. 6' -10"32424 AWNR.O. 2' -0" x 2' -0"H.H. 6' -10"ATTICACCESSR & SH.CS-WSP4' - 0" B.W.P.16" SH.16" SH.PAINTED CABINETSFULL TILE BACKSPLASH12/0 x 6/8R.O. 2' -2" x 6' -11"16' x 8' O.H.GARAGEDOOR138' x 8' O.H.GARAGEDOOR1148' - 0"CS-WSP5' - 0" B.W.P.22/4 x 6/8R.O. 2' -6" x 6' -11"CLOSETPED. SINK4' - 6"2' - 6"4' - 4"GAS LINE FOR RANGE1' - 0"GAS F.P.2' - 0"11' - 4"14' - 8"18" FLOOR TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSES@ 24" O.C.MUD ROOMFRAME BOTTOM OFWINDOW @ 44" A.F.F.3-2x6HHUS410HHUS4102-2x63-2x62-2x64" CONCRETE SLAB, SLOPETOWARDS DOORS5/8" TYPE X GYP. BD. ALL COMMONWALLS & CEILINGGARAGE PLATE HEIGHT TO MATCHMAIN FLOOR UNLESS NOTED OTHERWISEPFH1' - 9"PFH2' - 1"PFH2' - 1"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES1/4" = 1'-0"A-4031MAIN FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:2/24/2022 5:11:45 PMPAYTON XL MODELL10, B1 - KNOB HILL 2ND ADD'N5861 178TH STREET WESTLAKEVILLE, MN 55044A-403OTT294110610847942.24.22 CB8'-1 1/8"9'-1 1/8"8'-4" POUR2984THE PAYTON XLHeader Spans:Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ***
DN 17RBEDROOM #4LAUNDRYBEDROOM #3OWNER'S SUITEHALL1/2 WALL W/WOOD CAPSMOKEDET.SMOKEDET.6' VANITYCLOSETR & SH.32/6 x 6/8R.O. 2' -8" x 6' -11"SMOKEDET.R & SH.BEDROOM #2GIRDER TRUSSCO DET.SMOKEDET.MFG. ROOF TRUSSESPER MFG. SPACINGATTICACCESS2' LINEN32/6 x 6/8R.O. 2' -8" x 6' -11"42/6 x 6/8 PKTR.O. 5' -2" x 6' -11"4:124:12GIRDERTRUSS13' - 0"27' - 0"3' - 0"28' - 0"29' - 0"2' - 0"26' - 6"13' - 6"R & SH.22/4 x 6/8R.O. 2' -6" x 6' -11"22/4 x 6/8R.O. 2' -6" x 6' -11"6' - 4"14' - 6"5' - 8"6' - 9"6' - 9"32/6 x 6/8R.O. 2' -8" x 6' -11"CLOSETBATH2x63' VANITYR & SH.22/4 x 6/8R.O. 2' -6" x 6' -11"0' - 6"22/4 x 6/8R.O. 2' -6" x 6' -11"6' - 6"6' - 6"2' - 6"7' - 6"17' - 0"VAULT LINE2-2x10 W/2 TRIMMERS2-2x102-2x102-2x102-2x10CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.40' - 0"5' - 9"22' - 3"31' - 0"31' - 0"40' - 0"8' - 0"5' - 5"4' - 3"1' - 8"4' - 8"5' - 0"8' - 5"2' - 6"1' - 9 1/2"0' - 9 1/2"14' - 6"9' - 2"3' - 6"2' - 6"11' - 8 1/4"3' - 5 1/2"3' - 1"6' - 7 1/4"19' - 3 1/2"3' - 8 1/2"3' - 8 1/2"13' - 3 1/2"4' - 4"5' - 0"0' - 10"15' - 10"48" F.G.SHOWER W/ C.T. WALLS& BY-PASSDOORS@ 65"@ 65"@ 65"@ 65"2-2x102-2x10 W/2 TRIMMERS52424-2 FIXEDR.O. 4' -0" x 2' -0"H.H. 6' -10"32424 AWNR.O. 2' -0" x 2' -0"H.H. 6' -10"32424 AWNR.O. 2' -0" x 2' -0"H.H. 6' -10"96060 SLR.O. 5' -0" x 5' -0"H.H. 6' -10"86048 SLR.O. 5' -0" x 4' -0"H.H. 6' -10"86048 SLR.O. 5' -0" x 4' -0"H.H. 6' -10"224-48-2460 SLR.O. 8' -0" x 5' -0"H.H. 6' -10"5' TUB/SHWRSMOKEDET.WASHERDRYERDBL FRAMED FOR PLUMBING WALL3' x 5' TUB W/ TILEDECKKNEE WALL W/14" SPINDLESMFG. ROOF TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSESPER MFG. SPACINGEN SUITE52/8 x 6/8R.O. 2' -10" x 6' -11"32/6 x 6/8R.O. 2' -8" x 6' -11"32/6 x 6/8R.O. 2' -8" x 6' -11"2-2x63-2x63-2x63-2x6THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:2/24/2022 5:11:46 PMPAYTON XL MODELL10, B1 - KNOB HILL 2ND ADD'N5861 178TH STREET WESTLAKEVILLE, MN 55044A-404OTT294110610847942.24.22 CB8'-1 1/8"9'-1 1/8"8'-4" POUR2984THE PAYTON XL1/4" = 1'-0"A-4041UPPER FLOOR PLANCS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES3-2x6Header Spans:Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ***
WATCH DOG WATER PROOF COATINGFROM FOOTING TOSILL SEALER6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETRT'D 2x8 SILL PLATEW/ CLOSED CELL ROLLSILL SEALERGRADEGRANULAR FILL4" DRAIN TILEW/ SILT SOCK1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOORLOWER PLATE HEIGHT8' - 2"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.VERIFY FLOOR SYSTEMWITH FLOOR PLANSUPPER FLOOR PLATE HEIGHT8' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.3/4" T&GSUBFLOOR6 MIL. V.B.2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.1/2" OSBSHEATHINGTYVEK (OR EQUAL)ROLL HOUSE WRAPSIDING, VERIFYW/ ELEVATIONS5/8" GYP. BD.5/8" GYP. BD.VENTED ALUMINUMSOFFIT PANELSICE & WATER GUARDFROM EAVE TO 2'-0"MIN. OVER STRUCTUREVENT CHUTES & WIND WASH@ EACH TRUSS SPACEASPHALT SHINGLES W/15# ROLL FELT UNDER1/2" OSB ROOF SHEATHINGMFG. ROOFTRUSSES @ 24" O.C.ATTIC VENTINGAS PER CODER-49 MIN. BLOWNATTIC INSULATIONALUMINUM FASCIA W/2x6 SUB FASCIAALUMINUMDRIP EDGERIM JOISTRIM JOISTR-20 MIN. SPRAYFOAM INSULATION,COVER FOUNDATION WALLGMX THERMAL DRAINAGE BOARD(R-10) INSULATIONDRYVIT INSULATIONPROTECTION FROM SIDINGTO 6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITH OUTSIDE OF SHEATINGR-20 MIN. SPRAYFOAM INSULATION1' - 5"0' - 9 1/2"2x4 @ BOTTOM1x3 TYP.2x22x4 @ TOPSMOOTH LPSMARTSIDE TYP.SOFFIT1' - 9 1/2"1' - 0"FRONTSIDETOP VIEW1' - 5"0' - 9 1/2"FRAMING4x4 POSTTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:2/24/2022 5:11:47 PMPAYTON XL MODELL10, B1 - KNOB HILL 2ND ADD'N5861 178TH STREET WESTLAKEVILLE, MN 55044A-501OTT294110610847942.24.22 CB8'-1 1/8"9'-1 1/8"8'-4" POUR2984THE PAYTON XL3" MIN. ABS OR PVC GASTIGHTPIPE FROM SUBSLAB TOMIN. 12" ABOVE ROOF, MUSTBE RUN THRU CONDITIONED SPACE.PIPE CAN BE CONNECTED TOSUMP SYSTEM OR HAVE"T" FITTING (MIN. 10'-0" EA. WAY)IN GRAVEL UNDER SLAB.END OF PIPE MUST BE MIN. 10'-0"AWAY FROM ANY WINDOW OROTHER OPENING THAT IS LESSTHAN 2'-0" BELOW END OF PIPE. END OF PIPE MUST ALSO BEMIN. 10'-0" AWAY FROM ANYWINDOW OR OTHER OPENING INADJOINING OR ADJACENTBUILDINGS.SUFFICIENT SPACE MUST BELEFT AROUND PIPE IN ATTIC SPACETO ADD FAN. SPACE MUST BEMIN. ∅24" CENTERED ON AXIS OFPIPE W/ MIN. 3'-0" VERTICAL SPACE.A SINGLE PIPE CAN BE USED IF ALLSOIL GASES IN DWELLING CANFLOW FREELY BETWEEN ALL LEVELSOF FOUNDATION. THIS INCLUDESINTERIOR FOOTINGS & OTHERBARRIERS IF AIRFLOW HASBEEN ESTABLISHED.LABEL THE VENT PIPE AT LEASTONCE PER FLOOR AND INACCESSIBLE ATTICS WITH"RADON REDUCTION SYSTEM".ONE ELECTRICAL RECEPTACLE ISREQUIRED IN THE ATTIC NEARTHE VENT PIPE FOR OPT. FAN.:PASSIVE RADON SYSTEM:3/8" = 1'-0"A-5012TYP. WALL SECTIONWINDOW SCHEDULETYPE MARK MANUFACTURER MODEL COUNT UNIT ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT1 WINDSOR NEXT DIMENSION 1 24-48-2448 SL 8' - 0" 4' - 0" 6' - 10"2 WINDSOR NEXT DIMENSION 1 24-48-2460 SL 8' - 0" 5' - 0" 6' - 10"3 WINDSOR NEXT DIMENSION 3 2424 AWN 2' - 0" 2' - 0" 6' - 10"4 WINDSOR NEXT DIMENSION 1 2424 AWN FIXED 2' - 0" 2' - 0"2' - 6"5 WINDSOR NEXT DIMENSION 1 2424-2 FIXED 4' - 0" 2' - 0" 6' - 10"6 WINDSOR NEXT DIMENSION 2 3618 PIC 3' - 0" 1' - 6" 8' - 0"7 WINDSOR NEXT DIMENSION 1 4242 SL 3' - 6" 3' - 6" 7' - 2"8 WINDSOR NEXT DIMENSION 3 6048 SL 5' - 0" 4' - 0" 6' - 10"9 WINDSOR NEXT DIMENSION 1 6060 SL 5' - 0" 5' - 0" 6' - 10"10 WINDSOR NEXT DIMENSION 1 7260 SL 6' - 0" 5' - 0" 6' - 10"11 WINDSOR NEXT DIMENSION 3 P4260/A24 T 3' - 6" 7' - 0" 8' - 0"1/2" = 1'-0"A-5013TYP. COLUMNROOM FINISHED SCHEDULEFLOOR ROOM NAME FLOOR AREA PLATE HEIGHT COMMENTSLOWER FLOOR FAMILY ROOM CARPET 431 SF 8' - 2" .LOWER FLOOR BEDROOM #5 CARPET 153 SF 8' - 2" .LOWER FLOOR CLOSET CARPET 65 SF 8' - 2" .LOWER FLOOR STAIRWAY CARPET 66 SF 8' - 2"LOWER FLOOR MECHANICAL CONCRETE 182 SF 8' - 2" FINISH PER CODELOWER FLOOR BATH VINYL 48 SF 8' - 2" .MAIN FLOOR GREAT ROOM CARPET 244 SF 9' - 1 1/8" .MAIN FLOOR OFFICE CARPET 122 SF 9' - 1 1/8" .MAIN FLOOR STAIRWAY CARPET 77 SF 9' - 1 1/8"MAIN FLOOR GARAGE CONCRETE 627 SF 10' - 9 3/8"MAIN FLOOR PORCH CONCRETE 113 SF 9' - 1 1/8" .MAIN FLOOR MUD ROOM VINYL 48 SF 9' - 1 1/8" .MAIN FLOOR POWDER VINYL 30 SF 9' - 1 1/8" .MAIN FLOOR CLOSET VINYL 31 SF 9' - 1 1/8" .MAIN FLOOR KITCHEN WOOD 191 SF 9' - 1 1/8" .MAIN FLOOR DINING ROOM WOOD 110 SF 9' - 1 1/8" .MAIN FLOOR FOYER WOOD 118 SF 9' - 1 1/8" .UPPER FLOOR BEDROOM #4 CARPET 143 SF 8' - 1 1/8" .UPPER FLOOR BEDROOM #3 CARPET 139 SF 8' - 1 1/8" .UPPER FLOOR OWNER'S SUITE CARPET 182 SF 8' - 1 1/8" VAULTEDUPPER FLOOR HALL CARPET 77 SF 8' - 1 1/8" .UPPER FLOOR BEDROOM #2 CARPET 133 SF 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 56 SF 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 27 SF 8' - 1 1/8" .UPPER FLOOR EN SUITE L.V.T. 89 SF 8' - 1 1/8" .UPPER FLOOR LAUNDRY VINYL 30 SF 8' - 1 1/8" .UPPER FLOOR BATH VINYL 43 SF 8' - 1 1/8" .DOOR SCHEDULETYPE MARK DOOR SIZE ROUGH WIDTH ROUGH HEIGHT COUNT COMMENTS1 2/0 x 6/8 2' - 2" 6' - 11" 12 2/4 x 6/8 2' - 6" 6' - 11" 83 2/6 x 6/8 2' - 8" 6' - 11" 74 2/6 x 6/8 PKT 5' - 2" 6' - 11" 15 2/8 x 6/8 2' - 10" 6' - 11" 26 2/8 x 6/8 FIRE RATED 2' - 10" 6' - 10 1/4" 17 3/0 x 6/8 OPG. 18 3/0 x 6/8 W/ 12" D.S. SL'S 19 5/0 x 6/8 OPG. 110 6/0 x 6/8 SLIDER 6' - 0" 6' - 8" 111 8' x 8' O.H. GARAGE DOOR 112 12" TRANSOM / 6/0 x 6/8 SLIDER 113 16' x 8' O.H. GARAGE DOOR 1
6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"5000 PSI CONCRETE@ ALL FOOTINGS2" FOAMBOARD(R-10) INSULATION4" DRAIN TILEW/ SILT SOCKWATER PROOF COATING FROM FOOTING TOSILL SEALERANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" OSBSHEATHINGRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESTOOP, FLASH AS REQ'DAT HOUSE WALLPOUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERSIDING, VERIFYW/ ELEVATIONSTYVEK (OR EQUAL) ROLL HOUSE WRAP0' - 2"FROM SHEATHING TOOUTSIDE OF FOUNDATIONANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLAN3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION5/8" TYPE 'X' GYP BOARD,TAPE & MUD ALL SEAMSRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESLAB, FLASH AS REQ'DAT HOUSE WALL0' - 4"POUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALER0' - 8"FASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP.MIN. 3/8" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).MIN. 1000 LB HOLD-DOWNDEVICE (EMBEDDED INTOCONCRETE & NAILEDINTO FRAMING)FRONT ELEVATIONMIN. FOOTING SIZE UNDER OPENING IS12" X 12". A TURNED DOWN SLAB SHALLBE PERMITTED AT DOOR OPENINGS.MIN. (1) 5/8" DIA. ANCHOR BOLDINSTALLED PER R403.1.6 W/2" X 2" X 3/16" PLATE WASHER.MIN. REINFORCING OF FOUNDATION,ONE #4 BAR TOP & BOTTOM OFFOOTING. LAP BARS 15" MINIMUM.MIN. (2) 4200 LB STRAP-TYPE HOLD-DOWNS (EMBEDDED INTO CONCRETEAND NAILED INTO FRAMING)MIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 3/8" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INALL FRAMING (STUDS, BLOCKING AND SILLS) TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED9' - 11 1/4" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTAL2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.TRT'D SILL PLATEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSSLEEVE EVERY10'-0" MIN.6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODE5000 PSI CONCRETE@ ALL FOOTINGSWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESINSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONDRYVIT INSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITHOUTSIDE OF SHEATHINGTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:2/24/2022 5:11:48 PMPAYTON XL MODELL10, B1 - KNOB HILL 2ND ADD'N5861 178TH STREET WESTLAKEVILLE, MN 55044A-502OTT294110610847942.24.22 CB8'-1 1/8"9'-1 1/8"8'-4" POUR2984THE PAYTON XL1/2" = 1'-0"A-5021TYP. WALKOUT SECTION1/2" = 1'-0"A-5022TYP. HOUSE/STOOP WALL1/2" = 1'-0"A-5023TYP. HOUSE/GARAGE WALL3/8" = 1'-0"A-5024METHOD PFH - PORTAL FRAME WITH HOLD-DOWNS1/2" = 1'-0"A-5025BEARING WALL SECTION1/2" = 1'-0"A-5026TYP. LOOKOUT SECTION
NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION
This form must be completed and submitted with all new residential permit applications.
New residential building permits WILL NOT be issued without this completed form.
Project Site Address: _____________________________________________________________________
Company Name: _________________________________________________________________________
Primary Contact: _________________________________________________________________________
Phone # (24 hr Contact): ______________________ Email: ______________________________________
Description of Land Disturbing Activity: _____________________________________________________
NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___
If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an
erosion and sediment control plan MUST be submitted with the residential building permit application.
Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control
inspections and corrective actions:
Name of Person: ________________________________Company: _______________________________
Phone # (24 hr Contact): ______________________ Email: ______________________________________
Entity that Provided Training: ________________________ Certification Expiration Date: ____________
NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots.
No land disturbing activity may begin until a residential building permit has been issued.
I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National
Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER;
withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater
Permit (MN R 100001) or erosion and sediment control plan.
Signature: ________________________________________________ Date:_________________________
Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500
* If awaiting a MPCA permit transfer, provide MPCA proof of transfer submittal e-mail along with this form to
erosion@lakevillemn.gov
“The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.” (NPDES Construction Stormwater Permit, MPCA)
“The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA)
4/8/22 Y
AM