Loading...
HomeMy WebLinkAboutLA202167 - 16362 Jaffna Place-Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: Passive (No Fan) Active (With fan and monitoring device ) Location (or future location) of Fan: Other Please Describe Here Not applicable, all ducts located in conditioned space Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS: Capacity in Gallons:Other, describe: AFUE or HSPF% Cfm's " round duct OR " metal duct Not required per mech. code Passive Low: Other, describe: Low: Location of fan(s), describe: Cfm's " round duct OR " metal duct Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. New Construction Energy Code Compliance Certificate Name of Residential Contractor MN License Number City Mailing Address of the Dwelling or Dwelling Unit Rigid, Extruded PolystyreneHeat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: Combustion Air Select a Type Location of duct or system: Rim Joist (2nd Floor+) Building envelope air tightness: Below Entire Slab Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area THERMAL ENVELOPE Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM Total R-Value of all Types of InsulationType: Check All That Apply Mineral FiberboardInsulation Location Foam, Closed Cell Describe other insulated areas Ceiling, flat Non or Not ApplicableFiberglass, BlownFiberglass, Batts Foundation Wall Output in Tons: Appliances Cooling System Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Make-up Air Select a Type Domestic Water Heater Model Heating System Rim Joist (1st Floor) Average U-Factor (excludes skylights and one door ) U: Duct system air tightness: Rating or Size Efficiency Heating Gain Cooling Load Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Residential Load Calculation SEER /EER Capacity continuous ventilation rate in cfms: Heating Loss Manufacturer Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Date Cert. Posted R-value MECHANICAL SYSTEMS Builders Associaton of Minnesota version 101014 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Nov-17 06:51:44 Right-Suite® Universal 2021 21.0.08 RSU29636 Page 1 ...A\DR HORTON\DR Horton MN\2625 INT (FAIRFAX).rup Calc = MJ8 Front Door faces: NE 2625 INT (FAIRFAX) - CRY...Job:Load Short Form 11/17/2021Date:Entire House Energy Diagnostics, Inc.By: Energy Diagnostics, Inc. 405 E Archer Way, Valparaiso, IN 46383 Phone: 219-464-4457 Fax: 219-464-0035 Project Information DR Horton MNFor: 2625 INT (FAIRFAX) - CRYSTAL PARK, Minneapolis, MN Design Information InfiltrationClgHtg Blower doorMethod88-15Outside db (°F) 4 (substantial) / 2Shielding / stories7570Inside db (°F) 50 Pa / 813 cfmPressure / AVF1385Design TD (°F) M-Daily range 5050Inside humidity (%) 3555Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Bryant Make Bryant Trade Bryant Legacy Line 95 Gas Furn... Trade BRYANT HEATING AND COOLING SYS... Model 915SB30040E14 Cond BA13NA024BNG0G AHRI ref 0 Coil CNPVP2414ALA+915SB30040E14 AHRI ref 203498291 Efficiency 96 AFUE Efficiency 10.5 EER, 13 SEER Heating input Btuh40000 Sensible cooling Btuh15680 Heating output Btuh39000 Latent cooling Btuh6720 Temperature rise °F49 Total cooling Btuh22400 Actual air flow cfm753 Actual air flow cfm753 Air flow factor cfm/Btuh0.031 Air flow factor cfm/Btuh0.051 Static pressure in H2O0 Static pressure in H2O0 Space thermostat Load sensible heat ratio 0.81 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) 1/2 BATH 32 71 0 2 0 OWNERS SUITE 202 2295 2345 71 120 LAUNDRY 53 90 507 3 26 BATH 2 86 703 135 22 7 BED 2 150 2376 1162 74 59 OWNERS BATH 132 2779 827 86 42 OWNERS WIC 48 82 44 3 2 BED 3 139 3001 1218 93 62 KITCHEN 174 1686 3427 52 175 GREAT ROOM 405 4789 3253 149 166 MUD ROOM 40 952 255 30 13 FOYER 135 4615 593 144 30 MECH 55 94 51 3 3 OFFICE 60 102 710 3 36 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Nov-17 06:51:44 Right-Suite® Universal 2021 21.0.08 RSU29636 Page 2 ...A\DR HORTON\DR Horton MN\2625 INT (FAIRFAX).rup Calc = MJ8 Front Door faces: NE UPPER HALL 224 571 223 18 11 Entire House 1935 24207 14750 753 753 Other equip loads 7519 246 Equip. @ 0.93 RSM 13947 Latent cooling 3483 TOTALS 1935 31726 17430 753 753 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Nov-17 06:51:44Right-Suite® Universal 2021 21.0.08 RSU29636 Page 1...A\DR HORTON\DR Horton MN\2625 INT (FAIRFAX).rup Calc = MJ8 Front Door faces: NE 2625 INT (FAIRFAX) - CRY...Job:Project Summary 11/17/2021Date:Entire House Energy Diagnostics, Inc.By: Energy Diagnostics, Inc. 405 E Archer Way, Valparaiso, IN 46383 Phone: 219-464-4457 Fax: 219-464-0035 Project Information DR Horton MNFor:2625 INT (FAIRFAX) - CRYSTAL PARK, Minneapolis, MN Notes: Design Information Minneapolis, Crystal AP, MN, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F-15 Outside db °F88Inside db °F70 Inside db °F75Design TD °F85 Design TD °F13Daily range MRelative humidity %50Moisture difference gr/lb35 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh24207 Structure Btuh14750Ducts Btuh0 Ducts Btuh0Central vent (SER=64% 49 cfm) Btuh1610 Central vent (SER=64% 49 cfm) 246 BtuhHeat recovery Heat recoveryHumidification Btuh5909 Blower Btuh0Piping Btuh0Equipment load Btuh31726 Use manufacturer's data nRate/swing multiplier 0.93InfiltrationEquipment sensible load Btuh13947 Method Latent Cooling Equipment Load SizingBlower doorShielding / stories 4 (substantial) / 250 Pa / 813 cfmPressure / AVF Structure Btuh2330Ducts Btuh0Central vent (49 cfm) Btuh1154CoolingHeatingHeat recovery19351935Area (ft²) Equipment latent load Btuh34831626916269Volume (ft³)Air changes/hour 0.130.31 Equipment Total Load (Sen+Lat)Btuh17430Equiv. AVF (cfm) 3685 Req. total capacity at 0.70 SHR ton1.7 Heating Equipment Summary Cooling Equipment Summary Make Bryant Make BryantTrade Bryant Legacy Line 95 Gas Furn... Trade BRYANT HEATING AND COOLING SYS...Model 915SB30040E14 Cond BA13NA024BNG0GAHRI ref 0 Coil CNPVP2414ALA+915SB30040E14AHRI ref 203498291Efficiency 96 AFUE Efficiency 10.5 EER, 13 SEERHeating input Btuh40000 Sensible cooling Btuh15680Heating output Btuh39000 Latent cooling Btuh6720Temperature rise °F49 Total cooling Btuh22400Actual air flow cfm753 Actual air flow cfm753Air flow factor cfm/Btuh0.031 Air flow factor cfm/Btuh0.051Static pressure in H2O0 Static pressure in H2O0Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Nov-17 06:51:44 Right-Suite® Universal 2021 21.0.08 RSU29636 Page 1 ...A\DR HORTON\DR Horton MN\2625 INT (FAIRFAX).rup Calc = MJ8 Front Door faces: NE 2625 INT (FAIRFAX) - CRY...Job:Loads for Multiple Orientations 11/17/2021Date:Entire House Energy Diagnostics, Inc.By: Energy Diagnostics, Inc. 405 E Archer Way, Valparaiso, IN 46383 Phone: 219-464-4457 Fax: 219-464-0035 Project Information DR Horton MNFor: 2625 INT (FAIRFAX) - CRYSTAL PARK, Minneapolis, MN Design Conditions Location: CoolingHeatingIndoor: 7570Indoor temperature (°F)Minneapolis, Crystal AP, MN, US 1385Design TD (°F)ft869Elevation: 5050Relative humidity (%)°N45Latitude: Outdoor:35.554.5Moisture difference (gr/lb)CoolingHeating Infiltration:88-15Dry bulb (°F) )M(20-Daily range (°F) 73-Wet bulb (°F) 7.515.0Wind speed (mph) Front Door North Northeast East Southeast South Southwest West Northwest Sensible Load (Btuh) 11680 13947 13939 12537 11009 12792 13622 13104 Latent Load (Btuh) 3483 3483 3483 3483 3483 3483 3483 3483 Total Load (Btuh) 15164 17430 17422 16020 14492 16275 17105 16587 Heating AVF (cfm) 753 753 753 753 753 753 753 753 Cooling AVF (cfm) 753 753 753 753 753 753 753 753 Building Orientation Cooling Load Total Cooling Load (Btuh)Direction Front Door faces 0 5000 10000 15000 20000 N NE E SE S SW W NW Front Door faces NortheastCurrent Orientation: Front Door faces NortheastHighest Cooling Load: 2021-Nov-17 06:51:47 Right-Suite® Universal 2021 21.0.08 RSU29636 Page 1 ...A\DR HORTON\DR Horton MN\2625 INT (FAIRFAX).rup Calc = MJ8 Front Door faces: NE 2625 INT (FAIRFAX) - CRY...Job:Manual S Compliance Report 11/17/2021Date:Entire House Energy Diagnostics, Inc.By: Energy Diagnostics, Inc. 405 E Archer Way, Valparaiso, IN 46383 Phone: 219-464-4457 Fax: 219-464-0035 Project Information DR Horton MNFor: 2625 INT (FAIRFAX) - CRYSTAL PARK, Minneapolis, MN Cooling Equipment Design Conditions °F75.3Entering coil DB:Btuh14997Sensible gain:°F88.0Outdoor design DB: °F63.0Entering coil WB:Btuh3483Latent gain:°F73.0Outdoor design WB: Btuh18480Total gain:°F75.0Indoor design DB: cfm753Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ACEquipment type: BA13NA024BNG0G+CNPVP2414ALA+915SB30040E14Model:BryantManufacturer: cfm753Actual airflow: % of load116Btuh17358Sensible capacity: % of load125Btuh4346Latent capacity: %80SHR:% of load117Btuh21704Total capacity: Heating Equipment Design Conditions °F68.0Entering coil DB:Btuh31726Heat loss:°F-15Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Gas furnaceEquipment type: 915SB30040E14Model:BryantManufacturer: cfm753Actual airflow: °F49Temp. rise:% of load123Btuh39000Output capacity: Meets all requirements of ACCA Manual S. 2021-Nov-17 06:51:47 Right-Suite® Universal 2021 21.0.08 RSU29636 Page 1 ...A\DR HORTON\DR Horton MN\2625 INT (FAIRFAX).rup Calc = MJ8 Front Door faces: NE 2625 INT (FAIRFAX) - CRY...Job:Parts Order 11/17/2021Date: Energy Diagnostics, Inc.By: Energy Diagnostics, Inc. 405 E Archer Way, Valparaiso, IN 46383 Phone: 219-464-4457 Fax: 219-464-0035 BILL TO: SHIP TO: Attn: Attn: Phone: Phone: Fax: Fax: Notes: Ship viaDate requiredPurchase order #Ordered byOrder date ExtensionDiscUnit listTotalQtyDescriptionPart #Src pricepieces Rheia Duct System Equipment RHEA 000775.07753-in Duct Uninsulated10-00-190 RHEA 00080.080.03-in ferrule10-01-010 RHEA 00033.033.0Duct board Take Off Inside10-01-040 RHEA 00033.033.0Duct board Take Off Outside10-01-050 RHEA 00015.015.0Ceiling Boot Assembly10-01-220 RHEA 00015.015.0Ceiling Diffuser Assembly10-04-230 RHEA 00048.048.0Hanger Bar Assembly00-00-240 RHEA 00015.015.0Elbow Extension10-01-020 RHEA 00018.018.0High Sidewall Boot Assembly10-01-200 RHEA 00018.018.0Slotted Diffuser10-04-090 RHEA 0007.07.0Coupler10-01-030 0Subtotal, Rheia Duct System Equipment Duct System Equipment WSF 4.3004.301.01.0Round metal duct, D = 13"DDMt13 PGM 20.80020.801.01.0Plenum round take off, size 13"FPLG-13 WSF 84.6004.7018.018.0Round metal duct, D = 15"DDMt15 PGM 29.40029.401.01.0Round smooth elbow, size 15"FDELS-15 PGM 39.40039.401.01.0Return boot from round duct, size 15"FBTO-15 PGM 23.20023.201.01.0Plenum round take off with trans, size 15"FPLJ-15 WSF 0001.01.0Rectangular metal floor two way grill, 12"x12"FRGRMFT-1212 201.70Subtotal, Duct System Equipment 201.70Overall total 2021-Nov-17 06:51:47 Right-Suite® Universal 2021 21.0.08 RSU29636 Page 2 ...A\DR HORTON\DR Horton MN\2625 INT (FAIRFAX).rup Calc = MJ8 Front Door faces: NE 2021-Nov-17 06:51:47 Right-Suite® Universal 2021 21.0.08 RSU29636 Page 1 ...A\DR HORTON\DR Horton MN\2625 INT (FAIRFAX).rup Calc = MJ8 Front Door faces: NE 2625 INT (FAIRFAX) - CRY...Job:Parts Pull Order 11/17/2021Date: Energy Diagnostics, Inc.By: Energy Diagnostics, Inc. 405 E Archer Way, Valparaiso, IN 46383 Phone: 219-464-4457 Fax: 219-464-0035 BILL TO: SHIP TO: Attn: Attn: Phone: Phone: Fax: Fax: Notes: Ship viaDate requiredPurchase order #Ordered byOrder date QtyQtyTotalQtyDescriptionPart #Src returnedissuedpieces Rheia Duct System Equipment RHEA 7757753-in Duct Uninsulated10-00-190 RHEA 80.0803-in ferrule10-01-010 RHEA 33.033Duct board Take Off Inside10-01-040 RHEA 33.033Duct board Take Off Outside10-01-050 RHEA 15.015Ceiling Boot Assembly10-01-220 RHEA 15.015Ceiling Diffuser Assembly10-04-230 RHEA 48.048Hanger Bar Assembly00-00-240 RHEA 15.015Elbow Extension10-01-020 RHEA 18.018High Sidewall Boot Assembly10-01-200 RHEA 18.018Slotted Diffuser10-04-090 RHEA 7.07.0Coupler10-01-030 Duct System Equipment WSF 1.01.0Round metal duct, D = 13"DDMt13 PGM 1.01.0Plenum round take off, size 13"FPLG-13 WSF 18.018Round metal duct, D = 15"DDMt15 PGM 1.01.0Round smooth elbow, size 15"FDELS-15 PGM 1.01.0Return boot from round duct, size 15"FBTO-15 PGM 1.01.0Plenum round take off with trans, size 15"FPLJ-15 WSF 1.01.0Rectangular metal floor two way grill, 12"x12"FRGRMFT-1212 2021-Nov-17 06:51:47 Right-Suite® Universal 2021 21.0.08 RSU29636 Page 1 ...A\DR HORTON\DR Horton MN\2625 INT (FAIRFAX).rup Calc = MJ8 Front Door faces: NE 2625 INT (FAIRFAX) - CRY...Job:Duct System Summary 11/17/2021Date:Entire House Energy Diagnostics, Inc.By: Energy Diagnostics, Inc. 405 E Archer Way, Valparaiso, IN 46383 Phone: 219-464-4457 Fax: 219-464-0035 Project Information DR Horton MNFor: 2625 INT (FAIRFAX) - CRYSTAL PARK, Minneapolis, MN System Totals 0.240Coil pressure loss (in H2O)AverageDesign mode 0.163Supply duct pressure loss (in H2O) 0.185Return system pressure loss (in H2O)753Total design airflow (cfm) 0.589Total system pressure loss (in H2O)753Total actual airflow (cfm) Room Details AVF DiffAct AVFDsn AVFHtg AVFClg AVFHtg LoadClg LoadRoom Name (%)(cfm)(cfm)(cfm)(cfm)(Btuh)(Btuh) 858111207101/2 BATH -1779967112022952345OWNERS SUITE -2141432690507LAUNDRY 482114227703135BATH 2 -66367745923761162BED 2 -11576486422779827OWNERS BATH 353112328244OWNERS WIC -206278936230011218BED 3 11151145217516863427KITCHEN 416415814916647893253GREAT ROOM 1023213013952255MUD ROOM 18887144304615593FOYER 303113339451MECH 12020336102710OFFICE -1013151811571223UPPER HALL 2021-Nov-17 06:51:47 Right-Suite® Universal 2021 21.0.08 RSU29636 Page 2 ...A\DR HORTON\DR Horton MN\2625 INT (FAIRFAX).rup Calc = MJ8 Front Door faces: NE Supply Run Details LengthDamp PosVelocityDiamAct AVFDsn AVFReturnTrunkRun Name (ft)(fpm)(in)(cfm)(cfm) 3152003111rb1dmn11/2 BATH-A 2252003117rb1dmn1BATH 2 2252003117rb1dmn1BATH 2-A 48138632122rb1dmn1BED 2 45139632122rb1dmn1BED 2-A 43140432122rb1dmn1BED 2-B 46139332126rb1dmn1BED 3 44139932126rb1dmn1BED 3-A 49138232026rb1dmn1BED 3-B 25244932429rb1dmn1FOYER-B 20154732929rb1dmn1FOYER-C 15165733529rb1dmn1FOYER-D 5344032326rb1dmn1GREAT ROOM-A 11254932926rb1dmn1GREAT ROOM-B 12254332926rb1dmn1GREAT ROOM-C 17250232726rb1dmn1GREAT ROOM-D 12251132726rb1dmn1GREAT ROOM-E 7254532926rb1dmn1GREAT ROOM-F 13251932828rb1dmn1KITCHEN-C 18155733028rb1dmn1KITCHEN-E 18157033028rb1dmn1KITCHEN-G 24151532728rb1dmn1KITCHEN-H 20426531414rb1dmn1LAUNDRY-A 952093113rb1dmn1MECH 29244232321rb1dmn1MUD ROOM-A 21337432020rb1dmn1OFFICE-A 13153032832rb1dmn1OWNERS BATH 18155132932rb1dmn1OWNERS BATH-A 21149632632rb1dmn1OWNERS SUITE-A 18151232732rb1dmn1OWNERS SUITE-B 22149032632rb1dmn1OWNERS SUITE-C 1852053112rb1dmn1OWNERS WIC-A 41424731315rb1dmn1UPPER HALL Supply Trunk Details TrunkLengthDuctH x WDiamVelocClgHtgName (ft)Material(in)(in)(fpm)(cfm)(cfm) st10ShtMetl24x1212376753753dmn1 1ShtMetl0x013817753753st1 Return Branch Details TrunkDuctStud/JoistH x WDiamVelocTELClgHtgGrilleName MatlOpening (in)(in)(in)(fpm)(in)(cfm)(cfm)Size (in) ShMt0x015614887537530x0rb1 Job #: 2625 INT (FAIRFAX) - CRYSTAL PARK Performed by Energy Diagnostics, Inc. for: DR Horton MN 2625 INT (FAIRFAX) - CRYSTAL PARK Minneapolis, MN Energy Diagnostics, Inc. 405 E Archer WayValparaiso, IN 46383 Phone: 219-464-4457 Fax: 219-464-0035 Scale: 1 : 90 Page 1 Right-Suite® Universal 2021 21.0.08 RSU29636 2021-Nov-17 06:51:53...Horton MN\2625 INT (FAIRFAX).rup N MAIN KITCHEN 1/2 BATHMAIN RIGHT UNIT GREAT ROOM MUD ROOM FOYER MAIN LEFT UNIT KITCHEN-C 28 cfm 3.1 " Ceiling Round KITCHEN-E 30 cfm3.1 " Ceiling Round KITCHEN-H27 cfm 3.1 " Ceiling Round KITCHEN-G 30 cfm3.1 " Ceiling Round 1/2 BATH-A 11 cfm 3.1 " Ceiling Round MUD ROOM-A 23 cfm3.1 " Ceiling Round FOYER-B24 cfm 3.1 " Ceiling Round FOYER-C 29 cfm 3.1 " Ceiling Round FOYER-D 35 cfm 3.1 " Ceiling Round rb1753 cfm 12 " GREAT ROOM-A23 cfm 3.1 " Ceiling Round GREAT ROOM-B 29 cfm 3.1 " Ceiling Round GREAT ROOM-C 29 cfm 3.1 " Ceiling Round GREAT ROOM-D 27 cfm3.1 " Ceiling Round GREAT ROOM-E 27 cfm3.1 " Ceiling Round GREAT ROOM-F29 cfm 3.1 " Ceiling Round Insulated duct OR air barrer andinsulation need for duct routes of bed2/3 Job #: 2625 INT (FAIRFAX) - CRYSTAL PARK Performed by Energy Diagnostics, Inc. for: DR Horton MN 2625 INT (FAIRFAX) - CRYSTAL PARK Minneapolis, MN Energy Diagnostics, Inc. 405 E Archer WayValparaiso, IN 46383 Phone: 219-464-4457 Fax: 219-464-0035 Scale: 1 : 90 Page 2 Right-Suite® Universal 2021 21.0.08 RSU29636 2021-Nov-17 06:51:53...Horton MN\2625 INT (FAIRFAX).rup N UPPER OWNERS SUITE LAUNDRY BATH 2 BED 3 BED 2 OWNERS BATH OWNERS WIC UPPPER RIGHT UNIT MECH OFFICE UPPER HALL UPPER LEFT UNIT OWNERS WIC-A11 cfm 3.1 " Sidewall Slot OWNERS BATH-A 29 cfm 3.1 " Sidewall Slot OWNERS BATH 28 cfm3.1 " Sidewall SlotMECH11 cfm3.1 " Sidewall Slot OWNERS SUITE-B 27 cfm 3.1 " Sidewall Slot LAUNDRY-A 14 cfm 3.1 " Sidewall Slot OWNERS SUITE-A 26 cfm 3.1 " Sidewall Slot OWNERS SUITE-C 26 cfm3.1 " Sidewall Slot UPPER HALL 13 cfm 3.1 " Sidewall Slot OFFICE-A 20 cfm 3.1 " Sidewall Slot BATH 211 cfm 3.1 " Sidewall Slot BED 2-B 21 cfm3.1 " Sidewall Slot BED 3-A 21 cfm3.1 " Sidewall Slot BED 2-A 21 cfm 3.1 " Sidewall SlotBED 3 21 cfm3.1 " Sidewall Slot BED 221 cfm3.1 " Sidewall SlotBED 3-B 20 cfm 3.1 " Sidewall Slot BATH 2-A 11 cfm 3.1 " Sidewall Slot DOWNFLOWFURNACE