HomeMy WebLinkAboutLA202160 - 16356 Jaffna Place-Permit PackRESIDENTIAL BUILDING
PERMIT APPLICATION
CITY OF LAKEVILLE
BUILDING INSPECTIONS DEPARTMENT
20195 HOLYOKE AVENUE
LAKEVILLE, MN 55044
952-985-4440
Office Use Only
__________________
Permit Number
___________________
Received By
___________________
Date Received
___________________
Fee Total
SITE ADDRESS:
MAILING ADDRESS: CITY: STATE: ZIP:
JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________
LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________
ESTIMATED VALUATION: PROPOSED START DATE: END DATE:
(New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION:
APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL
NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED)
PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License)
RESIDENT OWNER
NAME:_______________________________________________________________________________
HOME PHONE #:_____________________________ CELL PHONE:___________________________
GENERAL CONTRACTOR
Homeowner
Contractor
CONTRACTOR:_______________________________________________________________________
LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE)
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
PLUMBING WORK
Homeowner
Contractor
CONTRACTOR:__________________________________________LICENSE #: PM______________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
MECHANICAL WORK
Homeowner
Contractor
CONTRACTOR:________________________________________ _______________________________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
BOND #:_______________________________________ EXPIRATION DATE____________________
SEWER/WATER CONTRACTOR
New Construction Only
NAME:________________________________________________ ______________________________
HOME PHONE _____________________________ CELL PHONE:______________________________
BOND #:_______________________________________ EXPIRATION DATE____________________
INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE
ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY
APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND
ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND
WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START
WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN.
NAME OF APPLICANT (Please Print)DATE
APPLICANT’S SIGNATURE:
www.lakevillemn.gov
RESIDENTIAL BUILDING PERMIT APPLICATION
PAGE 2
OFFICE USE ONLY
BUILDING PERMIT TYPE REQUIRED INSPECTIONS
SINGLE FAMILY DWELLING BUILDING
DUPLEX AS BUILT
TOWNHOUSE UNITS BUILDING FINAL
DETACHED TOWN HOUSE UNIT DECK FOOTING
CONDO FIREPLACE
ACESSORY BUILDING FOOTING
REROOF FOUNDATION
RESIDE FRAMING
PORCH FRAMING
GARAGES
INSULATION
RES ADDN/REPAIR/RMDL
DECK
PORCH
GARAGES LATH
LOWER LEVEL FINISH LOWER LEVEL FINAL
ADDITION OTHER
FOUNDATION ONLY PORCH FOOTING
MISCELLANEOUS POURED WALL
DEMO SEPTIC TANK REMOVAL
MOVED SITE
MECHANICAL
CITY BUILDING VALUATION: $AIR TEST
FINAL
BUILDING PERMIT FEES ROUGH-IN
$PERMIT FEE PLUMBING
$PLAN CHECK FINAL
$SURCHARGE ROUGH-IN
$METRO SAC METER SIZE
$CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE
$CITY SEWER HOOKUP UNIT SEWER/WATER
$LANDSCAPE ESCROW SEWER/WATER
$TREE ESCROW FINAL
$MISC ESCROW STREET DRAINTILE
$PLUMBING BUILDING INFORMATION
$MECHANICAL TYPE OF CONSTRUCTION
$SEWER WATER ZONING
$OTHER CODE EDITION
$TOTAL FIRE SUPPRESSION SYSTEM
OCCUPANCY GROUP
APPROVED BY:
BUILDING INSPECTOR: Date:
PLUMBING/MECHANICAL
INSPECTOR: Date:
COMMENTS:
Passive (No Fan)
Active (With fan and monitoring
device )
Location (or future location) of Fan:
Other Please Describe Here
Not applicable, all ducts located in conditioned space
Not required per mech. code
Passive
Powered
Interlocked with exhaust device. Describe:
Input in
BTUS:
Capacity in
Gallons:Other, describe:
AFUE or
HSPF%
Cfm's
" round duct OR
" metal duct
Not required per mech. code
Passive
Low: Other, describe:
Low:
Location of fan(s), describe: Cfm's
" round duct OR
" metal duct
Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution
panel.
New Construction Energy Code Compliance Certificate
Name of Residential Contractor MN License Number
City Mailing Address of the Dwelling or Dwelling Unit
Rigid, Extruded PolystyreneHeat Recover Ventilator (HRV) Capacity in cfms:
Energy Recover Ventilator (ERV) Capacity in cfms:
Combustion Air Select a Type
Location of duct or system:
Rim Joist (2nd Floor+)
Building envelope air tightness:
Below Entire Slab
Fuel Type
Solar Heat Gain Coefficient (SHGC):
Windows & Doors
Ceiling, vaulted
Bay Windows or cantilevered areas
Floors over unconditioned area
THERMAL ENVELOPE
Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade
RADON CONTROL SYSTEM
Total R-Value of all Types of InsulationType: Check All That Apply
Mineral FiberboardInsulation Location Foam, Closed Cell Describe other insulated areas
Ceiling, flat Non or Not ApplicableFiberglass, BlownFiberglass, Batts Foundation Wall
Output
in Tons:
Appliances Cooling System
Location of duct or system:
Heating or Cooling Ducts Outside Conditioned Spaces
Make-up Air Select a Type
Domestic Water
Heater
Model
Heating System
Rim Joist (1st Floor)
Average U-Factor (excludes skylights and one door ) U:
Duct system air tightness:
Rating or Size
Efficiency
Heating Gain Cooling Load
Select Type
Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace):
Residential Load
Calculation
SEER
/EER
Capacity continuous ventilation rate in cfms:
Heating Loss
Manufacturer
Total ventilation (intermittent + continuous) rate in cfms:
Balanced Ventilation capacity in cfms:
High:
High:
MECHANICAL VENTILATION SYSTEM
Date Cert. Posted
R-value
MECHANICAL SYSTEMS
Builders Associaton of Minnesota version 101014
Bold/italic values have been manually overridden
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Nov-17 06:51:44
Right-Suite® Universal 2021 21.0.08 RSU29636 Page 1
...A\DR HORTON\DR Horton MN\2625 INT (FAIRFAX).rup Calc = MJ8 Front Door faces: NE
2625 INT (FAIRFAX) - CRY...Job:Load Short Form 11/17/2021Date:Entire House Energy Diagnostics, Inc.By:
Energy Diagnostics, Inc.
405 E Archer Way, Valparaiso, IN 46383 Phone: 219-464-4457 Fax: 219-464-0035
Project Information
DR Horton MNFor:
2625 INT (FAIRFAX) - CRYSTAL PARK, Minneapolis, MN
Design Information
InfiltrationClgHtg
Blower doorMethod88-15Outside db (°F)
4 (substantial) / 2Shielding / stories7570Inside db (°F)
50 Pa / 813 cfmPressure / AVF1385Design TD (°F)
M-Daily range
5050Inside humidity (%)
3555Moisture difference (gr/lb)
HEATING EQUIPMENT COOLING EQUIPMENT
Make Bryant Make Bryant
Trade Bryant Legacy Line 95 Gas Furn... Trade BRYANT HEATING AND COOLING SYS...
Model 915SB30040E14 Cond BA13NA024BNG0G
AHRI ref 0 Coil CNPVP2414ALA+915SB30040E14
AHRI ref 203498291
Efficiency 96 AFUE Efficiency 10.5 EER, 13 SEER
Heating input Btuh40000 Sensible cooling Btuh15680
Heating output Btuh39000 Latent cooling Btuh6720
Temperature rise °F49 Total cooling Btuh22400
Actual air flow cfm753 Actual air flow cfm753
Air flow factor cfm/Btuh0.031 Air flow factor cfm/Btuh0.051
Static pressure in H2O0 Static pressure in H2O0
Space thermostat Load sensible heat ratio 0.81
ROOM NAME Area Htg load Clg load Htg AVF Clg AVF
(ft²)(Btuh)(Btuh)(cfm)(cfm)
1/2 BATH 32 71 0 2 0
OWNERS SUITE 202 2295 2345 71 120
LAUNDRY 53 90 507 3 26
BATH 2 86 703 135 22 7
BED 2 150 2376 1162 74 59
OWNERS BATH 132 2779 827 86 42
OWNERS WIC 48 82 44 3 2
BED 3 139 3001 1218 93 62
KITCHEN 174 1686 3427 52 175
GREAT ROOM 405 4789 3253 149 166
MUD ROOM 40 952 255 30 13
FOYER 135 4615 593 144 30
MECH 55 94 51 3 3
OFFICE 60 102 710 3 36
Bold/italic values have been manually overridden
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Nov-17 06:51:44
Right-Suite® Universal 2021 21.0.08 RSU29636 Page 2
...A\DR HORTON\DR Horton MN\2625 INT (FAIRFAX).rup Calc = MJ8 Front Door faces: NE
UPPER HALL 224 571 223 18 11
Entire House 1935 24207 14750 753 753
Other equip loads 7519 246
Equip. @ 0.93 RSM 13947
Latent cooling 3483
TOTALS 1935 31726 17430 753 753
Bold/italic values have been manually overridden
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Nov-17 06:51:44Right-Suite® Universal 2021 21.0.08 RSU29636 Page 1...A\DR HORTON\DR Horton MN\2625 INT (FAIRFAX).rup Calc = MJ8 Front Door faces: NE
2625 INT (FAIRFAX) - CRY...Job:Project Summary 11/17/2021Date:Entire House Energy Diagnostics, Inc.By:
Energy Diagnostics, Inc.
405 E Archer Way, Valparaiso, IN 46383 Phone: 219-464-4457 Fax: 219-464-0035
Project Information
DR Horton MNFor:2625 INT (FAIRFAX) - CRYSTAL PARK, Minneapolis, MN
Notes:
Design Information
Minneapolis, Crystal AP, MN, USWeather:
Winter Design Conditions Summer Design Conditions
Outside db °F-15 Outside db °F88Inside db °F70 Inside db °F75Design TD °F85 Design TD °F13Daily range MRelative humidity %50Moisture difference gr/lb35
Heating Summary Sensible Cooling Equipment Load Sizing
Structure Btuh24207 Structure Btuh14750Ducts Btuh0 Ducts Btuh0Central vent (SER=64% 49 cfm) Btuh1610 Central vent (SER=64% 49 cfm) 246 BtuhHeat recovery Heat recoveryHumidification Btuh5909 Blower Btuh0Piping Btuh0Equipment load Btuh31726 Use manufacturer's data nRate/swing multiplier 0.93InfiltrationEquipment sensible load Btuh13947
Method Latent Cooling Equipment Load SizingBlower doorShielding / stories 4 (substantial) / 250 Pa / 813 cfmPressure / AVF Structure Btuh2330Ducts Btuh0Central vent (49 cfm) Btuh1154CoolingHeatingHeat recovery19351935Area (ft²) Equipment latent load Btuh34831626916269Volume (ft³)Air changes/hour 0.130.31 Equipment Total Load (Sen+Lat)Btuh17430Equiv. AVF (cfm) 3685 Req. total capacity at 0.70 SHR ton1.7
Heating Equipment Summary Cooling Equipment Summary
Make Bryant Make BryantTrade Bryant Legacy Line 95 Gas Furn... Trade BRYANT HEATING AND COOLING SYS...Model 915SB30040E14 Cond BA13NA024BNG0GAHRI ref 0 Coil CNPVP2414ALA+915SB30040E14AHRI ref 203498291Efficiency 96 AFUE Efficiency 10.5 EER, 13 SEERHeating input Btuh40000 Sensible cooling Btuh15680Heating output Btuh39000 Latent cooling Btuh6720Temperature rise °F49 Total cooling Btuh22400Actual air flow cfm753 Actual air flow cfm753Air flow factor cfm/Btuh0.031 Air flow factor cfm/Btuh0.051Static pressure in H2O0 Static pressure in H2O0Space thermostat Load sensible heat ratio 0.81
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Nov-17 06:51:44
Right-Suite® Universal 2021 21.0.08 RSU29636 Page 1
...A\DR HORTON\DR Horton MN\2625 INT (FAIRFAX).rup Calc = MJ8 Front Door faces: NE
2625 INT (FAIRFAX) - CRY...Job:Loads for Multiple Orientations 11/17/2021Date:Entire House Energy Diagnostics, Inc.By:
Energy Diagnostics, Inc.
405 E Archer Way, Valparaiso, IN 46383 Phone: 219-464-4457 Fax: 219-464-0035
Project Information
DR Horton MNFor:
2625 INT (FAIRFAX) - CRYSTAL PARK, Minneapolis, MN
Design Conditions
Location: CoolingHeatingIndoor:
7570Indoor temperature (°F)Minneapolis, Crystal AP, MN, US
1385Design TD (°F)ft869Elevation:
5050Relative humidity (%)°N45Latitude:
Outdoor:35.554.5Moisture difference (gr/lb)CoolingHeating
Infiltration:88-15Dry bulb (°F)
)M(20-Daily range (°F)
73-Wet bulb (°F)
7.515.0Wind speed (mph)
Front Door North Northeast East Southeast South Southwest West Northwest
Sensible Load (Btuh) 11680 13947 13939 12537 11009 12792 13622 13104
Latent Load (Btuh) 3483 3483 3483 3483 3483 3483 3483 3483
Total Load (Btuh) 15164 17430 17422 16020 14492 16275 17105 16587
Heating AVF (cfm) 753 753 753 753 753 753 753 753
Cooling AVF (cfm) 753 753 753 753 753 753 753 753
Building Orientation Cooling Load
Total Cooling Load (Btuh)Direction Front Door faces
0
5000
10000
15000
20000
N NE E SE S SW W NW
Front Door faces NortheastCurrent Orientation:
Front Door faces NortheastHighest Cooling Load:
2021-Nov-17 06:51:47
Right-Suite® Universal 2021 21.0.08 RSU29636 Page 1
...A\DR HORTON\DR Horton MN\2625 INT (FAIRFAX).rup Calc = MJ8 Front Door faces: NE
2625 INT (FAIRFAX) - CRY...Job:Manual S Compliance Report 11/17/2021Date:Entire House Energy Diagnostics, Inc.By:
Energy Diagnostics, Inc.
405 E Archer Way, Valparaiso, IN 46383 Phone: 219-464-4457 Fax: 219-464-0035
Project Information
DR Horton MNFor:
2625 INT (FAIRFAX) - CRYSTAL PARK, Minneapolis, MN
Cooling Equipment
Design Conditions
°F75.3Entering coil DB:Btuh14997Sensible gain:°F88.0Outdoor design DB:
°F63.0Entering coil WB:Btuh3483Latent gain:°F73.0Outdoor design WB:
Btuh18480Total gain:°F75.0Indoor design DB:
cfm753Estimated airflow:%50Indoor RH:
Manufacturer's Performance Data at Actual Design Conditions
Split ACEquipment type:
BA13NA024BNG0G+CNPVP2414ALA+915SB30040E14Model:BryantManufacturer:
cfm753Actual airflow:
% of load116Btuh17358Sensible capacity:
% of load125Btuh4346Latent capacity:
%80SHR:% of load117Btuh21704Total capacity:
Heating Equipment
Design Conditions
°F68.0Entering coil DB:Btuh31726Heat loss:°F-15Outdoor design DB:
°F70.0Indoor design DB:
Manufacturer's Performance Data at Actual Design Conditions
Gas furnaceEquipment type:
915SB30040E14Model:BryantManufacturer:
cfm753Actual airflow:
°F49Temp. rise:% of load123Btuh39000Output capacity:
Meets all requirements of ACCA Manual S.
2021-Nov-17 06:51:47
Right-Suite® Universal 2021 21.0.08 RSU29636 Page 1
...A\DR HORTON\DR Horton MN\2625 INT (FAIRFAX).rup Calc = MJ8 Front Door faces: NE
2625 INT (FAIRFAX) - CRY...Job:Parts Order 11/17/2021Date:
Energy Diagnostics, Inc.By:
Energy Diagnostics, Inc.
405 E Archer Way, Valparaiso, IN 46383 Phone: 219-464-4457 Fax: 219-464-0035
BILL TO: SHIP TO:
Attn: Attn:
Phone: Phone:
Fax: Fax:
Notes:
Ship viaDate requiredPurchase order #Ordered byOrder date
ExtensionDiscUnit listTotalQtyDescriptionPart #Src pricepieces
Rheia Duct System Equipment
RHEA 000775.07753-in Duct Uninsulated10-00-190
RHEA 00080.080.03-in ferrule10-01-010
RHEA 00033.033.0Duct board Take Off Inside10-01-040
RHEA 00033.033.0Duct board Take Off Outside10-01-050
RHEA 00015.015.0Ceiling Boot Assembly10-01-220
RHEA 00015.015.0Ceiling Diffuser Assembly10-04-230
RHEA 00048.048.0Hanger Bar Assembly00-00-240
RHEA 00015.015.0Elbow Extension10-01-020
RHEA 00018.018.0High Sidewall Boot Assembly10-01-200
RHEA 00018.018.0Slotted Diffuser10-04-090
RHEA 0007.07.0Coupler10-01-030
0Subtotal, Rheia Duct System Equipment
Duct System Equipment
WSF 4.3004.301.01.0Round metal duct, D = 13"DDMt13
PGM 20.80020.801.01.0Plenum round take off, size 13"FPLG-13
WSF 84.6004.7018.018.0Round metal duct, D = 15"DDMt15
PGM 29.40029.401.01.0Round smooth elbow, size 15"FDELS-15
PGM 39.40039.401.01.0Return boot from round duct, size 15"FBTO-15
PGM 23.20023.201.01.0Plenum round take off with trans, size 15"FPLJ-15
WSF 0001.01.0Rectangular metal floor two way grill, 12"x12"FRGRMFT-1212
201.70Subtotal, Duct System Equipment
201.70Overall total
2021-Nov-17 06:51:47
Right-Suite® Universal 2021 21.0.08 RSU29636 Page 2
...A\DR HORTON\DR Horton MN\2625 INT (FAIRFAX).rup Calc = MJ8 Front Door faces: NE
2021-Nov-17 06:51:47
Right-Suite® Universal 2021 21.0.08 RSU29636 Page 1
...A\DR HORTON\DR Horton MN\2625 INT (FAIRFAX).rup Calc = MJ8 Front Door faces: NE
2625 INT (FAIRFAX) - CRY...Job:Parts Pull Order 11/17/2021Date:
Energy Diagnostics, Inc.By:
Energy Diagnostics, Inc.
405 E Archer Way, Valparaiso, IN 46383 Phone: 219-464-4457 Fax: 219-464-0035
BILL TO: SHIP TO:
Attn: Attn:
Phone: Phone:
Fax: Fax:
Notes:
Ship viaDate requiredPurchase order #Ordered byOrder date
QtyQtyTotalQtyDescriptionPart #Src returnedissuedpieces
Rheia Duct System Equipment
RHEA 7757753-in Duct Uninsulated10-00-190
RHEA 80.0803-in ferrule10-01-010
RHEA 33.033Duct board Take Off Inside10-01-040
RHEA 33.033Duct board Take Off Outside10-01-050
RHEA 15.015Ceiling Boot Assembly10-01-220
RHEA 15.015Ceiling Diffuser Assembly10-04-230
RHEA 48.048Hanger Bar Assembly00-00-240
RHEA 15.015Elbow Extension10-01-020
RHEA 18.018High Sidewall Boot Assembly10-01-200
RHEA 18.018Slotted Diffuser10-04-090
RHEA 7.07.0Coupler10-01-030
Duct System Equipment
WSF 1.01.0Round metal duct, D = 13"DDMt13
PGM 1.01.0Plenum round take off, size 13"FPLG-13
WSF 18.018Round metal duct, D = 15"DDMt15
PGM 1.01.0Round smooth elbow, size 15"FDELS-15
PGM 1.01.0Return boot from round duct, size 15"FBTO-15
PGM 1.01.0Plenum round take off with trans, size 15"FPLJ-15
WSF 1.01.0Rectangular metal floor two way grill, 12"x12"FRGRMFT-1212
2021-Nov-17 06:51:47
Right-Suite® Universal 2021 21.0.08 RSU29636 Page 1
...A\DR HORTON\DR Horton MN\2625 INT (FAIRFAX).rup Calc = MJ8 Front Door faces: NE
2625 INT (FAIRFAX) - CRY...Job:Duct System Summary 11/17/2021Date:Entire House Energy Diagnostics, Inc.By:
Energy Diagnostics, Inc.
405 E Archer Way, Valparaiso, IN 46383 Phone: 219-464-4457 Fax: 219-464-0035
Project Information
DR Horton MNFor:
2625 INT (FAIRFAX) - CRYSTAL PARK, Minneapolis, MN
System Totals
0.240Coil pressure loss (in H2O)AverageDesign mode
0.163Supply duct pressure loss (in H2O)
0.185Return system pressure loss (in H2O)753Total design airflow (cfm)
0.589Total system pressure loss (in H2O)753Total actual airflow (cfm)
Room Details
AVF DiffAct AVFDsn AVFHtg AVFClg AVFHtg LoadClg LoadRoom Name
(%)(cfm)(cfm)(cfm)(cfm)(Btuh)(Btuh)
858111207101/2 BATH
-1779967112022952345OWNERS SUITE
-2141432690507LAUNDRY
482114227703135BATH 2
-66367745923761162BED 2
-11576486422779827OWNERS BATH
353112328244OWNERS WIC
-206278936230011218BED 3
11151145217516863427KITCHEN
416415814916647893253GREAT ROOM
1023213013952255MUD ROOM
18887144304615593FOYER
303113339451MECH
12020336102710OFFICE
-1013151811571223UPPER HALL
2021-Nov-17 06:51:47
Right-Suite® Universal 2021 21.0.08 RSU29636 Page 2
...A\DR HORTON\DR Horton MN\2625 INT (FAIRFAX).rup Calc = MJ8 Front Door faces: NE
Supply Run Details
LengthDamp PosVelocityDiamAct AVFDsn AVFReturnTrunkRun Name
(ft)(fpm)(in)(cfm)(cfm)
3152003111rb1dmn11/2 BATH-A
2252003117rb1dmn1BATH 2
2252003117rb1dmn1BATH 2-A
48138632122rb1dmn1BED 2
45139632122rb1dmn1BED 2-A
43140432122rb1dmn1BED 2-B
46139332126rb1dmn1BED 3
44139932126rb1dmn1BED 3-A
49138232026rb1dmn1BED 3-B
25244932429rb1dmn1FOYER-B
20154732929rb1dmn1FOYER-C
15165733529rb1dmn1FOYER-D
5344032326rb1dmn1GREAT ROOM-A
11254932926rb1dmn1GREAT ROOM-B
12254332926rb1dmn1GREAT ROOM-C
17250232726rb1dmn1GREAT ROOM-D
12251132726rb1dmn1GREAT ROOM-E
7254532926rb1dmn1GREAT ROOM-F
13251932828rb1dmn1KITCHEN-C
18155733028rb1dmn1KITCHEN-E
18157033028rb1dmn1KITCHEN-G
24151532728rb1dmn1KITCHEN-H
20426531414rb1dmn1LAUNDRY-A
952093113rb1dmn1MECH
29244232321rb1dmn1MUD ROOM-A
21337432020rb1dmn1OFFICE-A
13153032832rb1dmn1OWNERS BATH
18155132932rb1dmn1OWNERS BATH-A
21149632632rb1dmn1OWNERS SUITE-A
18151232732rb1dmn1OWNERS SUITE-B
22149032632rb1dmn1OWNERS SUITE-C
1852053112rb1dmn1OWNERS WIC-A
41424731315rb1dmn1UPPER HALL
Supply Trunk Details
TrunkLengthDuctH x WDiamVelocClgHtgName
(ft)Material(in)(in)(fpm)(cfm)(cfm)
st10ShtMetl24x1212376753753dmn1
1ShtMetl0x013817753753st1
Return Branch Details
TrunkDuctStud/JoistH x WDiamVelocTELClgHtgGrilleName
MatlOpening (in)(in)(in)(fpm)(in)(cfm)(cfm)Size (in)
ShMt0x015614887537530x0rb1
Job #: 2625 INT (FAIRFAX) - CRYSTAL PARK
Performed by Energy Diagnostics, Inc. for:
DR Horton MN
2625 INT (FAIRFAX) - CRYSTAL PARK
Minneapolis, MN
Energy Diagnostics, Inc.
405 E Archer WayValparaiso, IN 46383
Phone: 219-464-4457 Fax: 219-464-0035
Scale: 1 : 90
Page 1
Right-Suite® Universal 2021
21.0.08 RSU29636
2021-Nov-17 06:51:53...Horton MN\2625 INT (FAIRFAX).rup
N
MAIN
KITCHEN
1/2 BATHMAIN RIGHT UNIT
GREAT ROOM
MUD ROOM
FOYER
MAIN LEFT UNIT
KITCHEN-C
28 cfm
3.1 " Ceiling Round
KITCHEN-E
30 cfm3.1 " Ceiling Round
KITCHEN-H27 cfm
3.1 " Ceiling Round
KITCHEN-G
30 cfm3.1 " Ceiling Round
1/2 BATH-A
11 cfm
3.1 " Ceiling Round
MUD ROOM-A
23 cfm3.1 " Ceiling Round
FOYER-B24 cfm
3.1 " Ceiling Round
FOYER-C
29 cfm
3.1 " Ceiling Round FOYER-D
35 cfm
3.1 " Ceiling Round
rb1753 cfm
12 "
GREAT ROOM-A23 cfm
3.1 " Ceiling Round
GREAT ROOM-B
29 cfm
3.1 " Ceiling Round
GREAT ROOM-C
29 cfm
3.1 " Ceiling Round
GREAT ROOM-D
27 cfm3.1 " Ceiling Round
GREAT ROOM-E
27 cfm3.1 " Ceiling Round
GREAT ROOM-F29 cfm
3.1 " Ceiling Round
Insulated duct OR
air barrer andinsulation need for
duct routes of bed2/3
Job #: 2625 INT (FAIRFAX) - CRYSTAL PARK
Performed by Energy Diagnostics, Inc. for:
DR Horton MN
2625 INT (FAIRFAX) - CRYSTAL PARK
Minneapolis, MN
Energy Diagnostics, Inc.
405 E Archer WayValparaiso, IN 46383
Phone: 219-464-4457 Fax: 219-464-0035
Scale: 1 : 90
Page 2
Right-Suite® Universal 2021
21.0.08 RSU29636
2021-Nov-17 06:51:53...Horton MN\2625 INT (FAIRFAX).rup
N
UPPER
OWNERS SUITE
LAUNDRY
BATH 2
BED 3 BED 2
OWNERS BATH
OWNERS WIC
UPPPER RIGHT UNIT
MECH
OFFICE
UPPER HALL
UPPER LEFT UNIT
OWNERS WIC-A11 cfm
3.1 " Sidewall Slot
OWNERS BATH-A
29 cfm
3.1 " Sidewall Slot
OWNERS BATH
28 cfm3.1 " Sidewall SlotMECH11 cfm3.1 " Sidewall Slot
OWNERS SUITE-B
27 cfm
3.1 " Sidewall Slot
LAUNDRY-A
14 cfm
3.1 " Sidewall Slot OWNERS SUITE-A
26 cfm
3.1 " Sidewall Slot
OWNERS SUITE-C
26 cfm3.1 " Sidewall Slot
UPPER HALL
13 cfm
3.1 " Sidewall Slot
OFFICE-A
20 cfm
3.1 " Sidewall Slot
BATH 211 cfm
3.1 " Sidewall Slot
BED 2-B
21 cfm3.1 " Sidewall Slot
BED 3-A
21 cfm3.1 " Sidewall Slot
BED 2-A
21 cfm
3.1 " Sidewall SlotBED 3
21 cfm3.1 " Sidewall Slot BED 221 cfm3.1 " Sidewall SlotBED 3-B
20 cfm
3.1 " Sidewall Slot
BATH 2-A
11 cfm
3.1 " Sidewall Slot
DOWNFLOWFURNACE