Loading...
HomeMy WebLinkAboutLA202190-19795 Henning Ave Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: *ALL DOOR & WINDOW HEADERSTO BE S.P.F. #2 OR BETTERwritten consent of Planco MN, Inc. modified or used in any redesign without the priormay not be assigned or copied, and may not bemay not be re-used for any additional structures,structure. Planco MN reserves all rights. These planslicense is granted to use these plans to build oneCopyright for these drawings is owned by Planco MN,Planco MN, Inc.cBERRES RIDGE MODEL #10#21-103SMA162021STONE COTTAGE CONSTRUCTION, INC. 19795 HENNING, LAKEVILLE LOT 5, BLOCK 2, BERRES RIDGE 7TH ADDITION FRONT ELEVATION 1/4" = 1'-0" WOOD PORCH10' CEILING @ FIRST FLOOR9' POURED FOUNDATIONTOTALBSM'T1st FLR.1,684 SQ. FT.1,367 SQ. FT.3,051 SQ. FT.VINYL B & BFRONT & SIDESVINYL SIDINGALL SIDESALUM. SOFFIT & FASCIAALL SIDESANDERSEN 100 SERIESWINDOWSSTONE AS SHOWNFRONT & RIGHT712TREX DECKINGVINYL B & B4121212VINYL B & B2'-2"12/12 METAL ROOFBRACKETS2/0x4/0 SH1'-6"121212x12 BOXEDCEDAR COL.9x8 OVH. DR.18x8 OVH. DR.VINYL B & BWDW. GRIDS AS SHOWNFRONT ONLYConcept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode05/23/2022dmathews Planco MN, Inc.C#21-103SMA262021GRADE LINESVERIFY ALL REAR ELEVATION 1/8" = 1'-0" VINYLCORNERSSIDINGVINYL 14' DECKLEDGER7121212 LEFT ELEVATION 1/8" = 1'-0" 1'-0"SIDINGVINYL VINYLCORNERS7124/1212/12SIDINGVINYL VINYLB & B12/12 RIGHT ELEVATION 1/8" = 1'-0" SIDINGVINYL VINYLCORNERS71212/1212/1212/121'-0"1'-0"VINYLB & B12/12 ROOF PLAN 1/8" = 1'-0" 71212121212712121212121'-0"12/12412121212122'-2"1'-6"1'-9"1'-0"1'-6"1'-0"Secure door closed until deck isconstructed with a separate permit. Planco MN, Inc.C#21-103SMA362021 BASEMENT PLAN 1/4" = 1'-0" 9' POURED FOUNDATION10"UP 16 R UNEXCAVATED 2" LEDGE2668266828682-2x102-7 1/4" LSLWHFURNF.D.92%*CARPET FAMILY/REC ROOM *UNFINISHED MECH/STORAGE 56'-0"38'-0" 48'-0"24'-6"23'-6"60'-0"34'-0"26'-0"12'-0"14'-0"2'-0" 4'-0"2'-6"4'-0" 8'-0"2" LEDGE27'-0"6'-6" 6'-0"17'-6"WALKOUTWALKOUT6'-2"5'-138"7'-0"7'-0"6'-0"15'-0"3'-6"8'-6"8'-6"3'-8" I.D.7'-0"1'-8"4'-0"4'-4"10'-0"15'-10"11'-6"TREATED 2x8 12" O.C. 8'-6"TRT. 3-2x10 FLUSH11 7/8" I JTS. 19.2" O.C. 11 7/8" I JTS. 19.2" O.C. 11 7/8" LSL JOISTS 6'-8"*L.V.T.F BEDROOM #4 BEDROOM #3 *CARPET*CARPET24682-2x10 W.I.C. *CARPET12'-0"30'-0"5'-10"”),1,6+('64)7 127,1&/8',1*67$,56 SUMP2x4 - 16" O.C.TRT. 4x4 CURB16x8 FTG.RADONVENT6'-6"1-11 7/8" LSLFLUSH1-11 7/8" LSLFLUSH16'-0"6/0x4/0 SL2-2x107'-8"14'-0"42'-0"4'-0"TRT. 3-2x10 FLUSHTRT. 3-2x10 FLUSH 8'-6"9"12'-6"9"2'-0" TREATED 2x8 12" O.C. 17'-0"4'-0"2'-0"2'-0"LOOKOUT LOOKOUT LOOKOUT2'-0"22'-6"12'-0"22'-0"2-9 1/2" LSL60610 P.D.(2) TRT. 6x6 POSTON 12x16 PIER FTG.24x24 FROST FTG.F.P.GAS7'-0"6/0x4/0 SL3-2x10266826682668266826685'-0" TUB& SHOWER1 PIECE FIB.246890"2068LIN.6/0x3/6 SL 2-2x10 4'-11"SH'S1/2 WALLW/ WD. CAPNO FTG.@ TOILET2x6 - 16" O.C.TRT. 4x6 CURB16x8 FTG.2'-8"13'-2"11'-0"4'-1"8'-5"2'-6"12'-0"9'-8"4'-0"3'-6"2'-10"11 7/8" I JTS. 19.2" O.C. BEDROOM #5 *CARPET10'-0"6/0x4/0 SL2-9 1/2" LSL11 7/8" I JTS. 19.2" O.C.BWPsAboveUFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. Planco MN, Inc.C#21-103SMA462021 FIRST FLOOR PLAN 1/4" = 1'-0" 1,684 SQ. FT.10' CEILING @ FIRST FLOOR18x8 OVH. DR.LIN. 48"48"24"2868246830803/0x6/0 SHTEMPTOP @ 8'24803'-0"2-2x105'-0" TUB & SHOWER 1 PIECE FIB.36"4'-6"4'-10"208026683080 C.O. FOYER *WOOD*4" CONC. FLOOR GARAGE *2x6 WALLS2868FIREDOOR2468246812" SH'SPANT.*WOODMICROOVEN/REF'G 36"30" COOTOPW/ HOOD4'-0"16" S.B.2'-2"2x62x2GASF.P.27'-6"14'-0"12'-0"2'-6"56'-0" WOOD PORCH 2/6x4/0-2 SHTOP @ 8'2-2x10*WOOD DINING KITCHEN *WOOD*WOOD GREAT ROOM *CARPET MASTER BEDROOM *CARPET OFFICE/BEDROOM #2 *CARPET W.I.C. *L.V.T. LNDRY *C.T.*WOOD MUD RM *WOOD W.I.C. *L.V.T.FF3'-6"2x6DN16 RTRUSSES 24" O.C.TRUSSES24" O.C.TRUSSES 24" O.C. TRUSSES 24" O.C. 10"3/6x6/6-3 FX3-2x1038'-0"7'-0"7'-0"6'-0"13'-10"7'-8"2-2x106080 P.D.6/0x5/0 SL2-2x106'-2"5'-10"48'-0"24'-6"23'-6"12'-1"5'-5"6'-0"22'-6"2'-0"60'-0"34'-0"26'-0"12'-0"12'-0"14'-0"1'-8"4'-8"6'-6"8'-2"3'-8" I.D.7'-0"1'-8"4'-0"3'-412"2'-0"6'-0"7'-0"7'-0"22'-0"4'-0"2'-6"4'-0" 8'-0" 8'-8"4'-4" 9'-4"5'-6"8'-0"4'-6"9'-0"8'-11"8'-4" 4'-4"3-7 1/4" LVL3068 C.O.*WOOD48482'-4"RAIL2-2x10*C.T.2'-2"2'-2"*12" BOX VAULT10'-0"7'-10"2'-6"2'-8"TOP @ 8'3"3"TOP @ 7'-4"2-2x10RADONVENT2 7 1/4" LSL 14' DECKLEDGER3-11 7/8" LSLCAB. ENDPANEL266826681/2 WALL W/ GLASS PANEL 14'-8" 16'-0"*TREX DECKINGLEGS3/0x6/0-3 FX2-2x10TOP @ 8'3"3"2468PKT.LTWD27"28682'-4"2468 C.O.2468PKT.F*C.T.17'-0"6'-0"15'-0" 4'-0" 2'-6"6'-0"6'-0"2'-6" 2-2x10 2/6x1/6 FX TOP @ 8'-6" 2-2x10 2/6x1/6 FX TOP @ 8'-6" 2-2x10 2/6x1/6 FX TOP @ 8'-6" 2'-1"4'-3"3'-8"4'-2"2x62x68'-1"2'-0"2'-0"2 7 1/4" LSL 8'-6" 8'-0"6"6"13'-0"6"9x8 OVH. DR.4'-0"GIRDERTRUSSES24" O.C. WOOD PORCH *TREX DECKINGTRUSSES24" O.C.12x12 BOXEDCEDAR COL.8'-0"7'-7"5'-8"4'-4"3'-8"7'-0"1'-0"SH'S DRESSERSPACE6'-4"5'-8"11'-0"11'-0"3080 C.O.2-2x1233CS-PFCS-PF6366PFHPFH-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ). Planco MN, Inc.C#21-103SMA562021 CROSS SECTION 3/8" = 1'-0" SHEATHINGSIDING1-2x6 TREATEDR-21 INSUL.10'-11 8"3 1/2" CONC. FLOORR-20 SPRAY FOAM1/2" GYP. BD.VB11 7/8" I JTS. @ 19.2" O.C.9'-0" POURED “WALL W/ REBARPER CODE3/4" T & G FLOORSILL PLATE2x6- 16" O.C.32'-0"5/8" GYP. BD.W/ V.B.2x6- 16" O.C.VB1/2" GYP. BD.R-21 INSUL.SIDINGSHEATHING(DESIGNED BY MFR)TRUSSES @ 24" O.C.R-49 INSUL.WATERPROOFINGGRADE8'-0"8'-6"R-10 W/ <2.6 ACHINSUL.TRT. 2x8 JTS. @ 16" O.C.24x24 FROSTFOOTING12x16 PIERFOOTINGTRT. 3-2x10TRT. 6x6 POST GREAT ROOM 6'-8" MIN. HDRM1x8 RISERS5/4x11 TREADS4- 2x12 STRINGERSTAIR NOTES:10" ROUGH CUT TREADSHOUSEWRAPHOUSEWRAPTREX DECKING10"7 7 16"19'-4"12'-8"ENERGY HEELFASCIAALUM. ALUM.SOFFITVENTED1'-9"3-7 1/4" LVL2'-2"10'-0"1'-0"5/8" GYP. BD.1-11 7/8" LSL50% ROOF 50% SOFFITROOF VENTS @ 1/300 ATTICVENTEDSOFFITALUM.ALUM. FASCIA1/2" SHTG.15# FELTSHINGLES1'-9"71212x12 BOXED COL.FOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECSDRAIN TILE FOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECSPOURED WALLGRADE2" FOAM758"2" FOAM W/“%(9(/512"4'-0"R-21 INSUL.1/2" GYP. BD.VB2x6- 16" O.C.5/8" GYP. BD.FLOOR SYSTEMROOFTRUSSPVC T-FITTINGTO SUPPORTVENT PIPEMIN. 4" OF GASPERMEABLE MATERIAL3 1/2" CONC. SLAB4" PVC VENT PIPESUPPORTSTRAPPINGFLASHINGEXHAUST 10' FROM OPNGS.INTO CONDITIONED SPACESOF BUILDING12" MIN. ABOVE ROOFSEAL6 MIL POLYUNDER SLAB10' OF DRAIN TILEEACH WAY FROMT-FITTING(ROCK) RADON GAS VENT SYSTEM 3/8" = 1'-0" 36" MIN. HT. CLEAR SPACE24" DIA. AROUND VENTPROVIDE ELECTRICALBOX POWER SOURCER-4 MIN. INSUL. VENT PIPE@ UNCONDITIONED SPACE4" MIN. CLEARANCEFOR FUT. FAN Planco MN, Inc.C#21-103SMA662021 CROSS SECTION 3/8" = 1'-0" SHEATHINGSIDING1-2x6 TREATEDR-20 SPRAY FOAMR-21 INSUL.10'-11 8"3 1/2" CONC. FLOORR-20 SPRAY FOAM1/2" GYP. BD.VB11 7/8" I JTS. @ 19.2" O.C.9'-0" POURED “WALL W/ REBARPER CODE3/4" T & G FLOORSILL PLATE2x6- 16" O.C.24'-0"5/8" GYP. BD.W/ V.B.2x6- 16" O.C.VB1/2" GYP. BD.R-21 INSUL.(DESIGNED BY MFR)TRUSSES @ 24" O.C.R-49 INSUL.WATERPROOFING4" CONC. FLOOR GARAGE GRADEPOURED WALL2X6- 16" O.C.24'-0"SLOPE(DESIGNED BY MFR)TRUSSES @ 24" O.C.R-10 W/ <2.6 ACHINSUL.1/2" GYP. BD. DINING HOUSEWRAPSIDINGSHEATHINGHOUSEWRAP BEDROOM #4 KITCHEN ENERGY HEELTRT. 4x4 CURB2x4- 16" O.C.50% ROOF 50% SOFFITROOF VENTS @ 1/300 ATTICVENTEDSOFFITALUM.ALUM. FASCIA1/2" SHTG.15# FELTSHINGLES1'-9"7125/8" GYP. BD.DRAIN TILE FOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECSFOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECSFOUNDATION & FTG.SIZES & DETAILSPER ENGINEER SPECSPOURED WALLGRADE2" FOAM758"2" FOAM W/“%(9(/512"4'-0"R-21 INSUL.1/2" GYP. BD.VB2x6- 16" O.C. BASEMENT PLAN 10"UP 16 R UNEXCAVATED 2" LEDGE2668266828682-2x102-2x10WHFURNF.D.92%*CARPET FAMILY/REC ROOM *UNFINISHED MECH/STORAGE 56'-0"38'-0" 48'-0"24'-6"23'-6"60'-0"34'-0"26'-0"12'-0"14'-0"2'-0" 4'-0"2'-6"4'-0" 8'-0"2" LEDGE27'-0"6'-6" 6'-0"17'-6"WALKOUTWALKOUT6'-2"5'-138"7'-0"7'-0"6'-0"15'-0"3'-6"8'-6"8'-6"3'-8" I.D.7'-0"1'-8"4'-0"4'-4"10'-0"15'-10"11'-6"TREATED 2x8 12" O.C. 8'-6"TRT. 3-2x10 FLUSH11 7/8" I JTS. 19.2" O.C. 11 7/8" I JTS. 19.2" O.C. 11 7/8" LSL JOISTS 6'-8"*L.V.T.F BEDROOM #4 BEDROOM #3 *CARPET*CARPET24682-2x10 W.I.C. *CARPET12'-0"30'-0"5'-10"SUMP2x4 - 16" O.C.TRT. 4x4 CURB16x8 FTG.RADONVENT6'-6"1-11 7/8" LSLFLUSH1-11 7/8" LSLFLUSH16'-0"6/0x4/0 SL3-2x107'-8"14'-0"42'-0"4'-0"TRT. 3-2x10 FLUSHTRT. 3-2x10 FLUSH 8'-6"9"12'-6"9"2'-0" TREATED 2x8 12" O.C. 17'-0"4'-0"2'-0"2'-0"LOOKOUT LOOKOUT LOOKOUT2'-0"22'-6"12'-0"22'-0"2-9 1/2" LSL60610 P.D.(2) TRT. 6x6 POSTON 12x16 PIER FTG.24x24 FROST FTG.F.P.GAS7'-0"6/0x4/0 SL3-2x10266826682668266826685'-0" TUB& SHOWER1 PIECE FIB.246890"2068LIN.6/0x3/6 SL 2-2x10 4'-11"SH'S1/2 WALLW/ WD. CAPNO FTG.@ TOILET2x6 - 16" O.C.TRT. 4x6 CURB16x8 FTG.2'-8"13'-2"11'-0"4'-1"8'-5"2'-6"12'-0"9'-8"4'-0"3'-6"2'-10"11 7/8" I JTS. 19.2" O.C. BEDROOM #5 *CARPET10'-0"6/0x4/0 SL3-2x1011 7/8" I JTS. 19.2" O.C.BWL 125'3'3'3'3' FIRST FLOOR PLAN 18x8 OVH. DR.LIN. 48"48"24"2868246830803/0x6/0 SHTEMPTOP @ 8'24803'-0"3-2x105'-0" TUB& SHOWER1 PIECE FIB.36"4'-6"4'-10"208026683080 C.O. FOYER *WOOD*4" CONC. FLOOR GARAGE *2x6 WALLS2868FIREDOOR2468246812" SH'SPANT.*WOODMICROOVEN/REF'G 36"30" COOTOPW/ HOOD4'-0"24" S.B.2'-2"2x62x2GASF.P.27'-6"14'-0"12'-0"2'-6"56'-0" WOOD PORCH 2/6x4/0-2 SHTOP @ 8'2-2x10*WOOD DINING KITCHEN *WOOD*WOOD GREAT ROOM *CARPET MASTER BEDROOM *CARPET OFFICE/BEDROOM #2 *CARPET W.I.C. *WOOD LNDRY *C.T.*WOOD MUD RM *WOOD W.I.C. *L.V.T.FF3'-6"2x6DN16 RTRUSSES 24" O.C.TRUSSES24" O.C.TRUSSES24" O.C. TRUSSES 24" O.C. 10"3/6x6/6-3 FX3-2x1038'-0"7'-0"7'-0"6'-0"13'-10"7'-8"2-2x106080 P.D.6/0x5/0 SL2-9 1/2" LSL6'-2"5'-10"48'-0"24'-6"23'-6"12'-1"5'-5"6'-0"22'-6"2'-0"60'-0"34'-0"26'-0"12'-0"12'-0"14'-0"1'-8"4'-8"6'-6"8'-2"3'-8" I.D.7'-0"1'-8"4'-0"3'-412"2'-0"6'-0"7'-0"7'-0"22'-0"4'-0"2'-6"4'-0" 8'-0" 8'-8"4'-4" 9'-10"5'-6"8'-0"4'-6"9'-0"8'-11"8'-4" 4'-4"3-7 1/4" LVL3068 C.O.*WOOD48482'-4"RAIL3-2x10*C.T.2'-2"2'-2"*12" BOX VAULT10'-0"7'-10"2'-6"2'-8"TOP @ 8'3"3"TOP @ 7'-4"2-2x10RADONVENT2-9 1/2" LSL 14' DECKLEDGER2-11 7/8" LSLCAB. ENDPANEL266826681/2 WALL W/ GLASS PANEL 14'-2" 16'-0"*TREX DECKINGLEGS3/0x6/0-3 FX3-2x10TOP @ 8'3"3"2468PKT.LTWD27"28682'-4"2468 C.O.2468PKT.F*C.T.17'-0"6'-0"15'-0" 4'-0" 2'-6"6'-0"6'-0"2'-6" 2-2x10 2/6x1/6 FX TOP @ 8'-6" 2-2x10 2/6x1/6 FX TOP @ 8'-6" 2-2x10 2/6x1/6 FX TOP @ 8'-6" 2'-1"4'-3"3'-8"4'-2"2x62x68'-1"2'-0"2'-0"2-9 1/2" LSL 8'-6" 8'-0"6"6"13'-0"6"9x8 OVH. DR.4'-0"GIRDERTRUSSES24" O.C. WOOD PORCH *TREX DECKINGTRUSSES24" O.C.12x12 BOXEDCEDAR COL.8'-0"7'-7"5'-8"4'-4"3'-8"7'-0"1'-0"SH'S DRESSERSPACE6'-4"5'-8"11'-0"11'-0"3080 C.O.BWL 2BWL 3BWL 4BWL 524'58'24'BWL 64'3'3'SEE DETAIL 2/PF-1SEE DETAIL 1/PF-14'6'6'6'3'4'4'4'4' Voigt & Associates, Inc.C-1Structural Engineering Services 4635 Nicols Road, Suite 204Eagan, MN 55122MethodCS-WSPWind speed 115Exposure CGB BWL 1 2 3 4 5 6Spacing - ft 25 24 24 24 58 58Level 2 1 1 1 1 1Length req'd- ft 7.8 3.9 7.7 3.9 8.7 8.7per Table R602.10.3(1)Adjustments:Exposure 1.2 1.2 1.2 1.2 1.2 1.2Eave to ridge Height 1.12 1.24 1.24 1.24 1.24 1.24Wall Height 0.95 1 1 1 1 1# of BWL 1 1.3 1.3 1.3 1 14" Gyp WB w.block joints1 1 1 1 1 1Adjusted Length 10.0 7.5 14.9 7.5 12.9 12.9Berres Ridge Model #1019795 Henning, Lakeville, MN Sheet Stone Cottage HVAC Load Calculations for Stone Cottage 19795 Henning Ave Lakeville,mn Prepared By: Randy Andrews Lofgren Heating 5708 Upper 147th Street West Apple Vallley, MN 55124 Monday, April 25, 2022 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 2 Project Report General Project Information Project Title:Stone Cottage Project Date:Monday, April 25, 2022 Client Name:Stone Cottage Client Address:19795 Henning Ave Client City:Lakeville,mn Company Name:Lofgren Heating Company Representative:Randy Andrews Company Address:5708 Upper 147th Street West Company City:Apple Vallley, MN 55124 Company E-Mail Address:rrandrews@lofgrenheating-ac.com Design Data Reference City:Minneapolis, Minnesota Building Orientation:Front door faces Northeast Daily Temperature Range:Medium Latitude:44 Degrees Elevation:834 ft. Altitude Factor:0.970 Elevation Sensible Adj. Factor:1.000 Elevation Total Adj. Factor:1.000 Elevation Heating Adj. Factor:1.000 Elevation Heating Adj. Factor:1.000 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter:-15 -15.33 80%n/a 72 n/a Summer:88 72 47%50%75 29 Check Figures Total Building Supply CFM:1,329 CFM Per Square ft.:0.395 Square ft. of Room Area:3,368 Square ft. Per Ton:1,172 Volume (ft³) of Cond. Space:30,312 Building Loads Total Heating Required Including Ventilation Air:47,349 Btuh 47.349 MBH Total Sensible Gain:28,804 Btuh 84 % Total Latent Gain:5,675 Btuh 16 % Total Cooling Required Including Ventilation Air:34,479 Btuh 2.87 Tons (Based On Sensible + Latent) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\19795 HENNING LAKEVILLE 04252022.rhv Monday, April 25, 2022, 10:54 AM Builders Associaton of Minnesota version 101014 Date Certificate Posted x Passive (No Fan) Active (With fan and monometer or other system monitoring Location (or future location) of Fan: Other Please Describe Here x 10/15 x x x 20 x 20 x 21 x 49 x x x x x Not applicable, all ducts located in conditioned space x Not required per mech. code Passive Powered Interlocked with exhaust device. Describe:Input in BTUS: 70,000 Capacity in Gallons: Other, describe: AFUE or HSPF% 93% Cfm's " round duct OR " metal duct Not required per mech. code x Passive Low: Other, describe: x Low: Location of fan(s), describe: Cfm's 4" " round duct OR Flex " metal duct City Mailing Address of the Dwelling or Dwelling Unit Combustion Air Select a Type Location of duct or system: 34,479 Below Entire Slab Rigid, Extruded Polystyrene Ceiling, flat Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. Place your logo here New Construction Energy Code Compliance Certificate Name of Residential Contractor Stone Cottage Construction Inc. MN License Number Lakeville19795 Henning Ave BC636874 Mech Room Heat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: 47,349 Heating Gain Cooling Load Attic Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area Rim Joist (2nd Floor+) 0.30 Appliances THERMAL ENVELOPE Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM Non or Not Applicable Cooling SystemTotal R-Value of all Types of InsulationType: Check All That Apply Mineral Fiberboard Insulation Location Foam, Closed Cell0.22 Describe other insulated areas Fiberglass, BlownFiberglass, Batts Foundation Wall R-value Average U-Factor (excludes skylights and one door) U: Duct system air tightness: Building envelope air tightness: Rim Joist (1st Floor) GPVL-50 13ACXN042-230 Model Heating System Natrual Gas Lennox Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Electric Make-up Air Select a Type AO Smith Domestic Water Heater MECHANICAL SYSTEMS Rating or Size Efficiency 13 Seer 200CFM Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): 28,804Residential Load Calculation SEER /EER Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Capacity continuous ventilation rate in cfms: ML193UH070 Heating Loss Manufacturer Lennox Natural Gas Output in Tons: 3 Ton50 NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. New residential building permits WILL NOT be issued without this completed form. Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ Primary Contact: _________________________________________________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Description of Land Disturbing Activity: _____________________________________________________ NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___ If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an erosion and sediment control plan MUST be submitted with the residential building permit application. “The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.” (NPDES Construction Stormwater Permit, MPCA) “The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA) Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name of Person: ________________________________Company: _______________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: ________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots. No land disturbing activity may begin until a residential building permit has been issued. I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 05/19/22 X KP