Loading...
HomeMy WebLinkAboutLA201407-Approved Temple_Plans_V2.1 StampedN149'-4"99'-4"149'-4"99' -4"33'-1"19'-0"82'-9"9'-11"RevJACOB TEMPLE RESIDENCE 17646 IBERIA AVE, LAKEVILLE, MN 55044 APN: 221960102100 DateDescriptionREVISIONSSignature with SealProject Name &AddressSheet SizeSheet NumberANSI B11" X 17"PV 0.0Sheet NameDRAWN BY2010 E HENNEPIN AVE, BLDG 6 BOX 7 MINNEAPOLIS, MINNESOTA, 55413 (509) 304-4658 LIC No.# BC708267/EA714757SHEET INDEX:PV 0.0:COVER SHEETPV 1.0:SITE PLANS 1.1:MOUNT DETAILSE 1.1:3-LINE DIAGRAME 1.2:NOTESE 1.3:WARNING LABELSDS:EQUIPMENT SPEC SHEETCOVER SHEETSCALE: NTS2SATELLITE VIEWPV 0.0SCALE: NTS3VICINITY MAPPV 0.0SCALE: 3/64" = 1'-0"1PLOT PLANPV 0.0GENERAL NOTES:a.INSTALLATION OF SOLARPHOTOVOLTAIC SYSTEM SHALL BE INACCORDANCE WITH NEC ARTICLE 690,AND ALL OTHER APPLICABLE NECCODES WHERE NOTED OR EXISTING.b.PROPER ACCESS AND WORKINGCLEARANCE AROUND EXISTING ANDPROPOSED ELECTRICAL EQUIPMENTWILL COMPLY WITH NEC ARTICLE 110.c.ALL CONDUCTORS, INCLUDING THEGROUNDING ELECTRODE CONDUCTORSHALL BE PROTECTED FROM PHYSICALDAMAGE IN ACCORDANCE WITH NECARTICLE 250.d.ALL DC WIRES SHALL BE SIZEDACCORDING TO [NEC 690.8]e.DC CONDUCTORS SHALL BE WITHINPROTECTED RACEWAYS INACCORDANCE WITH [NEC 690.31]f.ALL SIGNAGE TO BE PLACED INACCORDANCE WITH LOCALJURISDICTIONAL BUILDING CODE.g.PV MODULES TO BE RATED UL 1703CLASS A FIRE RATING OR BETTER.h.ALL EQUIPMENT TO BE CERTIFIED BY ANATIONALLY RECOGNIZED TESTINGLABORATORY.PROTECTION OF EMERGENCY RESPONDERSALL SHARP EDGES AND FASTENER TIPS SHALL BECOVERED OR CRIMPED OVER TO ELIMINATE SHARPEDGES, TO MINIMIZE RISK OF INJURY TO EMERGENCYRESPONDERS.ALL ROOF MOUNTED CONDUITS, BOXES, ANDEQUIPMENT CROSSING PATHWAYS ARE TO BECLEARLY IDENTIFIED BY A RED/WHITE REFLECTIVETAPE OR OTHER APPROVED MATERIAL. ROOF ACCESS POINTROOF ACCESS POINT SHALL NOT BE LOCATED IN AREASTHAT REQUIRE THE PLACEMENT OF GROUND LADDERSOVER OPENINGS SUCH AS WINDOWS OR DOORS, ANDLOCATED AT STRONG POINTS OF BUILDINGCONSTRUCTION IN LOCATIONS WHERE THE ACCESSPOINT DOES NOT CONFLICT WITH OVERHEADOBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS.SYSTEM SIZE: 21.535 kW DC18.000 kW ACMODULE TYPE & AMOUNT:(59) Q.CELLS Q.PEAK DUO BLK - G10 +360WMODULE DIMENSIONS:(L/W/H) 67.59"/41.14"/1.26"INVERTER:(30) AP SYSTEM YC600 [240V]INTERCONNECTION METHOD: LINE SIDE TAPPHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC ROOF MOUNT SYSTEM59 MODULES-ROOF MOUNTED - 21.535 kW DC, 18.000 kW AC, 17646 IBERIA AVE, LAKEVILLE, MN 55044 (LAT. 44.6934, LONG. -93.2498)PROPERTY LINEPROPERTY LINEPROPERTY LINE PROPERTY LINE IBERIA AVEFRONT OF HOUSEROOF ACCESS POINTFENCEROOF #1(12) Q.CELLS Q.PEAK DUO BLK - G10+360WSLOPE: 30°AZIM.: 258°ROOF #2(04) Q.CELLS Q.PEAK DUO BLK - G10+360WSLOPE: 30°AZIM.: 78°ROOF #3(13) Q.CELLS Q.PEAK DUO BLK - G10+360WSLOPE: 30°AZIM.: 168°ROOF #4(15) Q.CELLS Q.PEAKDUO BLK - G10 +360WSLOPE: 30°AZIM.: 258°ROOF #5(15) Q.CELLS Q.PEAK DUO BLK - G10+360WSLOPE: 30°AZIM.: 78°SHEDMEXISTING INTERIOR MAINSERVICE PANEL TIED TOEXTERIOR UTILITY METER #N/ADRIVEWAYMAIN HOUSEGARAGEGOVERNING CODESALL WORK SHALL CONFORM TO THE FOLLOWING CODES·2018 INTERNATIONAL BUILDING CODE·2018 INTERNATIONAL RESIDENTIAL CODE·2018 INTERNATIONAL EXISTING BUILDING CODE·2018 INTERNATIONAL FIRE CODE·2018 INTERNATIONAL PLUMBING CODE·2018 INTERNATIONAL MECHANICAL CODE·2018 INTERNATIONAL FUEL GAS CODE·2018 INTERNATIONAL ENERGY CONSERVATION CODE·2020 NATIONAL ELECTRIC CODEI hereby certify that this plan,specification or report was preparedby me or under my direct supervisionand that I am a duly LicensedProfessional Engineer under the lawsof the State of Minnesota,Brett D. Veazie, License No. 56392,Expiration Date: 30-June-202204/19/2022VSE Project Number: U1922.1432.221Vector Structural Engineering has reviewed the existingstructure with loading from the solar array and screwconnections to the existing framing. The design of theracking system, racking connections, and all otherstructural is by others. Mechanical, architectural, and allother nonstructural aspects of the design are by others.Electrical is by others, unless stamped by Dean Levorsen. 3'-5"28'-0"7"6'-3"22'-9"3'-10"3'-0"21'-0"2'-1"NEW PV ATTACHMENTSAT 4 '-0" O.C.NRevJACOB TEMPLE RESIDENCE 17646 IBERIA AVE, LAKEVILLE, MN 55044 APN: 221960102100 DateDescriptionREVISIONSSignature with SealProject Name &AddressSheet SizeSheet NumberANSI B11" X 17"PV 1.0Sheet NameDRAWN BY2010 E HENNEPIN AVE, BLDG 6 BOX 7 MINNEAPOLIS, MINNESOTA, 55413 (509) 304-4658 LIC No.# BC708267/EA714757EQUIPMENTLAYOUT & SITEPLANROOF SECTION(S)MODULE, ARRAY WEIGHT (LOAD CALC'S)Number of Modules59Module Weight43.87LBSTotal Module (Array) Weight2588.33LBSNumber of Attachment point145Mounting System Weight(Per Module)1.5LBSMounting System Weight217.50LBSTotal System Weight(Module Weight + Mounting System Weight)2805.83LBSWeight at Each Attachment Point(Array Weight / Number of Attachment Point)17.85LBSModule Area (67.59"x41.14")19.31SqFtTotal Array Area1139.30SqFtDistributed Load(Total System Weight / Total Array Area)2.27Per SqFtTotal Roof Area2144SqFtTotal Percentage of Roof CoveredTotal Array Area / Total Roof Area)*10053.14%MODULE - 15SLOPE - 30°AZIMUTH - 78°MATERIAL - COMP SHINGLETRUSS SIZE & SPACING - 2''X4'' @ 24'' O.C.ROOF #05MODULE - 13SLOPE - 30°AZIMUTH - 168°MATERIAL - COMP SHINGLETRUSS SIZE & SPACING - 2''X4'' @ 24'' O.C.MODULE - 04SLOPE - 30°AZIMUTH - 78°MATERIAL - COMP SHINGLETRUSS SIZE & SPACING - 2''X4'' @ 24'' O.C.MODULE - 12SLOPE - 30°AZIMUTH - 258°MATERIAL - COMP SHINGLETRUSS SIZE & SPACING - 2''X4'' @ 24'' O.C.MODULE - 15SLOPE - 30°AZIMUTH - 258°MATERIAL - COMP SHINGLETRUSS SIZE & SPACING - 2''X4'' @ 24'' O.C.ROOF #01ROOF #02ROOF #03ROOF #04SCALE: 1/8" = 1'-0"1SITE PLANPV 1.0SYSTEM SIZE: 21.535 kW DC18.000 kW ACMODULE TYPE & AMOUNT:(59) Q.CELLS Q.PEAK DUO BLK - G10 +360WMODULE DIMENSIONS:(L/W/H) 67.59"/41.14"/1.26"INVERTER:(30) AP SYSTEM YC600 [240V]PHOTOVOLTAIC SYSTEM SPECIFICATIONS:LCNEW SOLAR LOAD CENTERSYSTEM LEGENDEXISTING INTERIOR MAIN SERVICE PANEL & POINTOF INTERCONNECTION. TIED TO EXTERIOR UTILITYMETER .NEW PHOTOVOLTAIC UTILITY PRODUCTION METER.NEW PHOTOVOLTAIC UTILITY DISCONNECT SWITCH.LOCATED WITHIN 10' OF MSP.59 NEW Q.CELLS Q.PEAK DUO BLK - G10 +360WMODULES WITH NEW 30 - AP SYSTEM YC600 [240V]INVERTERS, MOUNTED ON THE BACK OF EACHMODULES.MPAC= EXTERIOR RUN= CONDUIT ROOF TOP JUNCTION BOX= FIRE PATHWAY= ATTACHMENT POINTS= TRUSS= ROOF OBSTRUCTIONS= RACKING SYSTEMCIRCUIT #5 - 12 MODULESCIRCUIT #4 - 10 MODULESCIRCUIT #3 - 09 MODULESCIRCUIT #2 - 14 MODULESCIRCUIT #1 - 14 MODULESCIRCUIT(S)MPACLCEXISTING INTERIOR MAIN SERVICEPANEL & POINT OF INTERCONNECTION.TIED TO EXTERIOR UTILITY METERNEW PV AC DISCONNECT GROUPEDWITH SERVICE EQUIPMENT (VISIBLE,LOCKABLE, LABELED)NEW PV METERNEW SOLAR LOAD CENTERROOF #01ROOF #02ROOF #03ROOF #04ROOF #0536" FIRE SETBACK36" FIRE SETBACK36" F IRE SETBACK36" FIRE SETBACK36" FIRE SETBACK36" FIRE SETBACK IBERIA AVEFRONT OF HOUSE36" FIRE SETBACK36" FIRE SETBACKI hereby certify that this plan, specificationor report was prepared by me or under mydirect supervision and that I am a dulyLicensed Professional Engineer under thelaws of the State of Minnesota,Brett D. Veazie, License No. 56392,Expiration Date: 30-June-202204/19/2022VSE Project Number: U1922.1432.221Vector Structural Engineering has reviewed the existingstructure with loading from the solar array and screwconnections to the existing framing. The design of theracking system, racking connections, and all otherstructural is by others. Mechanical, architectural, and allother nonstructural aspects of the design are by others.Electrical is by others, unless stamped by Dean Levorsen. RevJACOB TEMPLE RESIDENCE 17646 IBERIA AVE, LAKEVILLE, MN 55044 APN: 221960102100 DateDescriptionREVISIONSSignature with SealProject Name &AddressSheet SizeSheet NumberANSI B11" X 17"S 1.1Sheet NameDRAWN BY2010 E HENNEPIN AVE, BLDG 6 BOX 7 MINNEAPOLIS, MINNESOTA, 55413 (509) 304-4658 LIC No.# BC708267/EA714757MOUNT DETAILNOTE: - CONTRACTOR/INSTALLER TO VERIFY COMPATIBILITY OF ANYBRANDS OR PRODUCTS SUBSTITUTED OR USED AS ALTERNATESWITHIN ANY BRAND-SPECIFIC SYSTEMS.CONTRACTOR SHALL SUPPLY AND PRESENT CERTIFICATES OFCOMPATIBILITY TO THE BUILDING OFFICIAL UPON INSPECTION.PV MODULE(E) SINGLE LAYER OFCOMP SHINGLE ROOFIRONRIDGE INTEGRATEDGROUNDING & END/MID CLAMPPV MODULESIRONRIDGE XR-100 RAILFLASHING2''X4'' TRUSS @ 24'' OC5/16"x4.75" SS LAG BOLT WITHMIN 2-1/2" THREAD EMBEDMENT,SEALED PENETRATION2''X4'' TRUSS @ 24'' OCSCALE: NTS2ATTACHMENT DETAIL ENLARGED VIEWS 1.1SCALE: NTS1ATTACHMENT DETAIL (SIDE VIEW)S 1.1GENERAL STRUCTURAL NOTES:1.THE SOLAR PANELS ARE TO BE MOUNTED TO THEROOF FRAMING USING THE IRONRIDGE RACKINGSYSTEM WITH FLASH FOOT 2 ATTACHMENTS. THEMOUNTING FEET ARE TO BE SPACED AS SHOWNIN THE DETAILS, AND MUST BE STAGGERED TOADJACENT FRAMING MEMBERS TO SPREAD OUTTHE ADDITIONAL LOAD.2.UNLESS NOTED OTHERWISE, MOUNTINGANCHORS SHALL BE 5/16" LAG SCREWS WITH AMINIMUM OF 2-1/2" PENETRATION INTO ROOFFRAMING.3.THE PROPOSED PV SYSTEM ADDS 2.27 PSF TOTHE ROOF FRAMING SYSTEM.4.ROOF LIVE LOAD = 20 PSF TYPICAL, 0 PSF UNDERNEW PV SYSTEM.5.GROUND SNOW LOAD = 50 PSF6.WIND SPEED = 115 MPH7.EXPOSURE CATEGORY = C8.RISK CATEGORY = IISEE (2/S 1.1) FORENLARGED VIEWIRONRIDGE FLASH FOOT 2I hereby certify that this plan, specificationor report was prepared by me or under mydirect supervision and that I am a dulyLicensed Professional Engineer under thelaws of the State of Minnesota,Brett D. Veazie, License No. 56392,Expiration Date: 30-June-202204/19/2022VSE Project Number: U1922.1432.221Vector Structural Engineering has reviewed the existingstructure with loading from the solar array and screwconnections to the existing framing. The design of theracking system, racking connections, and all otherstructural is by others. Mechanical, architectural, and allother nonstructural aspects of the design are by others.Electrical is by others, unless stamped by Dean Levorsen. RevJACOB TEMPLE RESIDENCE 17646 IBERIA AVE, LAKEVILLE, MN 55044 APN: 221960102100 DateDescriptionREVISIONSSignature with SealProject Name &AddressSheet SizeSheet NumberANSI B11" X 17"E 1.1Sheet NameDRAWN BY2010 E HENNEPIN AVE, BLDG 6 BOX 7 MINNEAPOLIS, MINNESOTA, 55413 (509) 304-4658 LIC No.# BC708267/EA7147573-LINEDIAGRAMAP SYSTEM QS1 CABLE TO BE ATTACHEDTO RAIL MIN. 3-1/2" ABOVE ROOF SURFACESYSTEM SIZE: 21.535 kW DC18.000 kW ACMODULE: (59)Q.CELLS Q.PEAK DUO BLK - G10 +360WINVERTER: (30)AP SYSTEM YC600 [240V]WIREQTYWIRETAG #CONDUITWIRE TYPEINVERTERQTY:NOC:CONDUITFILL:TEMPRATING:WIREAMPTEMPDE-RATE:WIREOCP:GRNDSIZEGRND WIRETYPEWIREGAUGE:TERMINAL75°C RATING:NEC:STRINGAMPSxx=x x =1.252.28A0719.95A28.80A 25A90°C50Ax x =1.252.28A07#8 THWN-219.95Axx=20.90A90°C100Ax x =1.252.28A30#8 THWN-285.50Axx=94.00A75°C30A#1255A#8100A#31-1/4"EMT1-1/4"EMTWIRE FROM - -JUNCTION BOX TO LOAD CENTERLOAD CENTER TO MSPARRAY TO JUNCTION BOX123QS1 CABLETHWN-2THWN-2100.5031.00PV WIRE0.960.760.9410NA#6SBCGN 150AM(E) LOADSGNEXISTING GROUNDINGELECTRODE SYSTEM3EXISTING 240V/150A BUS BAR RATING,MAIN SERVICE PANEL, SINGLE PHASE,WITH A 150A MAIN DISCONNECTUTILITY COMPANY - DAKOTAELECTRIC ASSOCIATIONBIDIRECTIONA UTILITY METERPOINT OF INTERCONNECT, LINE SIDE(N) LOCKABLE BLADETYPE FUSIBLE ACDISCONNECT NEMA 3R100A-2P 120/240VAC90A FUSESLINE SIDE TAP(E) LOADSL1L2NGGL1L1L2L2N20AG07 MICRO-INVERTERS IN BRANCH CIRCUIT #1L2L2L1L120A07 MICRO-INVERTERS IN BRANCH CIRCUIT #2L2L2L1L105 MICRO-INVERTERS IN BRANCH CIRCUIT #320AL2L2L1L105 MICRO-INVERTERS IN BRANCH CIRCUIT #420A20AL2L2L1L106 MICRO-INVERTERS IN BRANCH CIRCUIT #512(N) JUNCTION BOX600 V, NEMA 3RUL LISTED(N) 125A SOLAR LOAD CENTER,NEMA 3R, 120/240VAC59 NEW Q.CELLS Q.PEAK DUO BLK - G10 +360WMODULES WITHNEW 30 - AP SYSTEM YC600 [240V] UL1741 CERTIFIED240VAC, 2.28AMAX CEC WEIGHTED EFFICIENCY 96.5%NEMA 3R, UL LISTED, INTERNAL GFDIM(N) 125A PHOTOVOLTAICMETER3Rooftop conductor ampacities designed in compliance withart. 690.8, Tables 310.15(B)(2)(a), 310.15(B)(3)(a),310.15(B)(3)(c), 310.15(B)(16), Chapter 9 Table 4, 5, & 9.Location specific temperature obtained from ASHRAE 2017data tablesAMBIENT TEMP (HIGH TEMP 2%)RECORD LOW TEMP-26°C32°CCONDUIT HEIGHT0.5"ROOF TOP TEMP54°CCONDUCTOR TEMPERATURE RATE90°CPV MODULE RATING @ STCMANUFACTURERMAX. POWER-POINT CURRENT (IMP)MAX. POWER-POINT VOLTAGE (VMP)OPEN-CIRCUIT VOLTAGE (VOC)SHORT-CIRCUIT CURRENT (ISC)10.49 AMPS34.31 VOLTS41.18 VOLTS11.04 AMPSNOM. MAX. POWER AT STC (PMAX)MAX. SYSTEM VOLTAGEVOC TEMPERATURE COEFFICIENT365 WATTQ.CELLS Q.PEAK DUO BLK - G10 +360W1000V-0.27° %/°CINVERTER SPECIFICATIONSMANUFACTURERMAX. POWER AT 40 C60 VOLTSNOMINAL AC VOLTAGE548 WATTSMAX. AC CURRENT240 VOLTSMAX. OCPD RATINGMAX. PANELS/CIRCUITSHORT CIRCUIT CURRENT2.28 AMPS15 AMPSMAX. DC VOLT RATING1415 AMPSAP SYSTEM YC600 MICRO INVERTERS3(N) SURGEPROTECTIONDEVICESURGE PROTECTION TO BEADDED AS REQUIRED PER THENEC 230.67 CLAUSENOTE: - WIRES LOCATED IN READILYACCESSIBLE LOCATIONS SHALL BE GUARDED PER NEC 690.31(A) RevJACOB TEMPLE RESIDENCE 17646 IBERIA AVE, LAKEVILLE, MN 55044 APN: 221960102100 DateDescriptionREVISIONSSignature with SealProject Name &AddressSheet SizeSheet NumberANSI B11" X 17"E 1.2Sheet NameDRAWN BY2010 E HENNEPIN AVE, BLDG 6 BOX 7 MINNEAPOLIS, MINNESOTA, 55413 (509) 304-4658 LIC No.# BC708267/EA714757NOTES SITE NOTES:1.A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHAREGULATIONS.2.THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AUTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES.3.THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL,OR BUILDING ROOF VENTS.4.PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSEDELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26.5.ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED INACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'SINSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THEBUILDING OR STRUCTURE.EQUIPMENT LOCATIONS:1.ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26.2.WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTEDOPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31 (A),(C) AND NEC TABLES310.15 (B)(2)(A) AND 310.15 (B)(3)(C).3.JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULESACCORDING TO NEC 690.34.4.ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOTWITHIN SIGHT OF THE AC SERVICING DISCONNECT. 2.2.6 ALL EQUIPMENT SHALL BEINSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NECAPPLICABLE CODES.5.ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOORUSAGE WHEN APPROPRIATE.STRUCTURAL NOTES:1.RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TOCODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATEDSPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCEBEYOND EITHER EDGE OF THE ARRAY / SUBARRAY, ACCORDING TO RAIMANUFACTURER’S INSTRUCTIONS.2.JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS. IFROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCALREQUIREMENTS.3.ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED W/APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR.4.ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THESPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 2.3.6 WHENPOSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGEREDAMONGST THE ROOF FRAMING MEMBERS.WIRING & CONDUIT NOTES:1.ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE.CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODEREQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING.2.CONDUCTORS SIZED ACCORDING TO NEC 690.8, NEC 690.7.3.VOLTAGE DROP LIMITED TO 1.5%.4.DC WIRING LIMITED TO MODULE FOOTPRINT. MICRO INVERTER WIRINGSYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/ SUITABLEWIRING CLIPS.5.AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACKPHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3-BLUE, YELLOW, ORANGE**, OR OTHER CONVENTION NEUTRAL- WHITE OR GREYIN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TOBE MARKED ORANGE [NEC 110.15].GROUNDING NOTES:1.GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, ANDGROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCHUSE.2.PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND MINIMUMNEC TABLE 250.122.3.METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURESCONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.136(A).4.EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC690.45 AND MICRO INVERTER MANUFACTURERS’ INSTRUCTIONS.5.EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN INMANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARENOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIEDGROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATIONREQUIREMENTS.6.THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THATTHE REMOVAL OFA MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TOANOTHER MODULE.7.GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOREDGREEN OR MARKED GREEN IF #4 AWG OR LARGER [NEC 250.119]8.THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC 250.50THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, AGROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO NEC 250, NEC 690.47AND AHJ.9.GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.41(B)(1) AND (2) TOREDUCE FIRE HAZARDSDISCONNECTION AND OVER-CURRENT PROTECTION NOTES:1.DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH ISOPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THETERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS).2.DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BELOCKABLE, AND BE A VISIBLE-BREAK SWITCH3.PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPIDSHUTDOWN FUNCTION TO REDUCE SHOCK HAZARD FOR EMERGENCYRESPONDERS IN ACCORDANCE WITH 690.12(A) THROUGH (D).4.ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8, 690.9, AND240.5.MICRO INVERTER BRANCHES CONNECTED TO A SINGLE BREAKER OR GROUPEDFUSES IN ACCORDANCE WITH NEC 110.3(B).6.IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTIONACCORDING TO NEC 690.11 AND UL1699B.INTERCONNECTION NOTES:1.LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH [NEC 705.12 (B)]2.THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAY NOTEXCEED 120% OF BUS BAR RATING [NEC 705.12(D)(2)(3)].3.THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUIT CURRENTAND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUS BARSHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUS BAR, PVDEDICATED BACKFEED BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUSFROM THE UTILITY SOURCE OCPD [NEC 705.12(B)(2)(3)].4.AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL, TOTALRATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OFBUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE EXCLUDEDACCORDING TO NEC 705.12 (B)(2)(3)(C).5.FEEDER TAP INTERCONNECTION (LOADSIDE) ACCORDING TO NEC 705.12 (B)(2)(1)6.SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.12 (A) WITHSERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230.422.7.8BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPTFROM ADDITIONAL FASTENING [NEC 705.12 (B)(5)]. NRevJACOB TEMPLE RESIDENCE 17646 IBERIA AVE, LAKEVILLE, MN 55044 APN: 221960102100 DateDescriptionREVISIONSSignature with SealProject Name &AddressSheet SizeSheet NumberANSI B11" X 17"E 1.3Sheet NameDRAWN BY2010 E HENNEPIN AVE, BLDG 6 BOX 7 MINNEAPOLIS, MINNESOTA, 55413 (509) 304-4658 LIC No.# BC708267/EA714757WARNINGLABELSCAUTION:POWER TO THIS BUILDING IS ALSO SUPPLIEDFROM THE FOLLOWING SOURCES WITHDISCONNECTS LOCATED AS SHOWNNEC 705.10 - MAIN SERVICE PANEL(59) PV MODULESLOAD CENTERASOLAR PV SYSTEMEQUIPPED WITH RAPIDSHUTDOWNTURN RAPIDSHUTDOWNSWITCH TO THE"OFF" POSITION TOSHUTDOWN PVSYSTEM ANDREDUCESHOCK HAZARDIN THE ARRAYSOLARELECTRICPV PANELSLABEL LOCATION: MAIN SERVICE DISCONNECTPER CODE: NEC 690.56(C)(1)(a)WARNING: PHOTOVOLTAICPOWER SOURCELABEL LOCATION: EMT, CONDUIT RACEWAY,CABLE TRAYSPER CODE: NEC 690.31(G)(3-4)LABEL LOCATION: POINT OF INTERCONNECTIONPER CODE: NEC 690.54PHOTOVOLTAIC SYSTEM AC DISCONNECTRATED AC OPERATING CURRENT 68.40 AMPSAC NOMINAL OPERATING VOLTAGE 240 VOLTSELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONWARNING!LABEL LOCATION: COMBINER PANEL, ACDISCONNECT, POINT OF INTERCONNECTIONPER CODE(S): NEC 690.13(B)WARNING!DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEMLABEL LOCATION: MAIN SERVICE DISCONNECTPER CODE: NEC 705.12(B)(3-4), NEC 690.59MAIN PHOTOVOLTAICSYSTEM DISCONNECTLABEL LOCATION: MAIN SERVICE DISCONNECT, UTILITY METERPER CODE: NEC 690.13(B)POWER SOURCE OUTPUTCONNECTION. DO NOT RELOCATETHIS OVERCURRENT DEVICE.WARNING!LABEL LOCATION: MAIN SERVICE DISCONNECT, POINT OFINTERCONNECTIONPER CODE: 705.12(B)(2)(3)(b)TURN OFF PHOTOVOLTAIC ACDISCONNECT PRIOR TOWORKING INSIDE PANELWARNING!LABEL LOCATION: COMBINER PANEL(S), MAINSERVICE DISCONNECTPER CODE(S): NEC 110.27(C), OSHA 1910.145(f)(7)LABEL LOCATION: AC DISCONNECTPER CODE: NEC 690.13(B)DO NOT DISCONNECT UNDERLOADLABEL LOCATION: MAIN SERVICE DISCONNECTPER CODE: NEC 690.15(C) & NEC 690.33(E)(2)RAPID SHUTDOWN SWITCHFOR SOLAR PV SYSTEMLABEL LOCATION: RSD INITIATION DEVICE, AC DISCONNECTPER CODE: NEC 690.56(C)(3) PV SYSTEM DISCONNECTTHIS EQUIPMENT FED BY MULTIPLE SOURCES,TOTAL RATING OF ALL OVERCURRENT DEVICES,EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE,SHALL NOT EXCEED AMPACITY OF BUSBAR.WARNING!LABEL LOCATION: POINT OF INTERCONNECTION, COMBINER PANELPER CODE: NEC 705.12(B)(2)(3)(c) IBERIA AVEMAIN SERVICEPANELPV METERACDISCONNECTUTILITY METERMPACLC