HomeMy WebLinkAboutLA201981 - 7067 183rd St W Permit PackRESIDENTIAL BUILDING
PERMIT APPLICATION
CITY OF LAKEVILLE
BUILDING INSPECTIONS DEPARTMENT
20195 HOLYOKE AVENUE
LAKEVILLE, MN 55044
952-985-4440
Office Use Only
__________________
Permit Number
___________________
Received By
___________________
Date Received
_______ _______
Fee Total
SITE ADDRESS:
MAILING ADDRESS: CITY: STATE: ZIP:
JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________
LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________
ESTIMATED VALUATION: PROPOSED START DATE: END DATE:
(New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION:
APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL
NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED)
PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License)
RESIDENT OWNER
NAME:_______________________________________________________________________________
HOME PHONE #:_____________________________ CELL PHONE:___________________________
GENERAL CONTRACTOR
Homeowner
Contractor
CONTRACTOR:_______________________________________________________________________
LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE)
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
PLUMBING WORK
Homeowner
Contractor
CONTRACTOR:__________________________________________LICENSE #: PM______________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
MECHANICAL WORK
Homeowner
Contractor
CONTRACTOR:________________________________________ _______________________________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
BOND #:_______________________________________ EXPIRATION DATE____________________
SEWER/WATER CONTRACTOR
New Construction Only
NAME:________________________________________________ ______________________________
HOME PHONE _____________________________ CELL PHONE:______________________________
BOND #:_______________________________________ EXPIRATION DATE____________________
INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE
ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY
APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND
ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND
WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START
WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN.
NAME OF APPLICANT (Please Print)DATE
APPLICANT’S SIGNATURE:
www.lakevillemn.gov
4/26/22
DM
RESIDENTIAL BUILDING PERMIT APPLICATION
PAGE 2
OFFICE USE ONLY
BUILDING PERMIT TYPE REQUIRED INSPECTIONS
SINGLE FAMILY DWELLING BUILDING
DUPLEX AS BUILT
TOWNHOUSE UNITS BUILDING FINAL
DETACHED TOWN HOUSE UNIT DECK FOOTING
CONDO FIREPLACE
ACESSORY BUILDING FOOTING
REROOF FOUNDATION
RESIDE FRAMING
PORCH FRAMING
GARAGES
INSULATION
RES ADDN/REPAIR/RMDL
DECK
PORCH
GARAGES LATH
LOWER LEVEL FINISH LOWER LEVEL FINAL
ADDITION OTHER
FOUNDATION ONLY PORCH FOOTING
MISCELLANEOUS POURED WALL
DEMO SEPTIC TANK REMOVAL
MOVED SITE
MECHANICAL
CITY BUILDING VALUATION: $AIR TEST
FINAL
BUILDING PERMIT FEES ROUGH-IN
$PERMIT FEE PLUMBING
$PLAN CHECK FINAL
$SURCHARGE ROUGH-IN
$METRO SAC METER SIZE
$CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE
$CITY SEWER HOOKUP UNIT SEWER/WATER
$LANDSCAPE ESCROW SEWER/WATER
$TREE ESCROW FINAL
$MISC ESCROW STREET DRAINTILE
$PLUMBING BUILDING INFORMATION
$MECHANICAL TYPE OF CONSTRUCTION
$SEWER WATER ZONING
$OTHER CODE EDITION
$TOTAL FIRE SUPPRESSION SYSTEM
OCCUPANCY GROUP
APPROVED BY:
BUILDING INSPECTOR: Date:
PLUMBING/MECHANICAL
INSPECTOR: Date:
COMMENTS:
MAIN FLOOR1' -8 1/4"UPPER PLATE20' -7 1/4"T.O. FOUNDATION0' -0"T.O. FOUNDATION0' -0"MAIN PLATE10' -9 3/8"MAIN PLATE10' -9 3/8"UPPER FLOOR12' -6 1/8"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"UPPER FLOOR PLATE HEIGHT8' - 1 1/8"GARAGE PLATE HEIGHT10' - 9 3/8"VINYL FRIEZEBOARD @ FRONT TYP.VINYL SHAKESCULTURED STONEW/ CONCRETE CAPALUMINUM SOFFIT& FASCIA TYP.4' - 0"VINYL CORNER TRIM @ FRONT TYP.6" BUMPED OUT LOUVER W/ CORBELS VINYL BOARD& BATTEN TYP.PLANTER BOX W/ BRACKETS 12" ARCH12" ARCHSEE COLUMN DETAILSHEET A-5010' - 3"ADDRESS STONE 8" 12"4" / 12"4" / 12"8" / 12"8" 12"4" VINYL TRIM @ WINDOWS &DOORS TYP.VINYL LAP @ FRONT TYP.8" 12"1' - 1"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:3/16/2022 10:20:46 AMTHE YUSUF RESIDENCEL8, B2 - GLACIER CREEK 2ND ADD'N7067 183RD STREET WESTLAKEVILLE, MN 55044A-201OTT2813.16.22 CB1598145911981.21.22 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4255THE RILEY1/4" = 1'-0"A-2011FRONT ELEVATIONSHEET INDEXSHEET NUMBER SHEET NAMEA-201 ELEVATIONA-202 ELEVATIONSA-401 FOUNDATIONA-402 LOWER FLOORA-403 MAIN FLOORA-404 UPPER FLOORA-501 SCHEDULES/ DETAILSA-502 DETAILSConcept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode05/17/2022dmathews
24" RETURNS TYP.6" / 12"8" / 12"8" / 12"8" / 12"MAIN FLOOR1' -8 1/4"UPPER PLATE20' -7 1/4"ALUMINUM SOFFIT& FASCIA TYP.VINYL SIDING &CORNERS TYP.GREAT RM. PLATE11' -9 3/8"OWNER'S SUITE FLOOR13' -6 1/8"OWNER'S SUITE PLATE21' -7 1/4"8' - 1 1/8"10' - 1 1/8"8" 12"6" 12"1' - 0"8" / 12"8" 12"8" 12"6" / 12"8" / 12"8" / 12"8" / 12"4" 12"8" 12"STANDARD ENERGY HEELS @ 8:12 & 6:1218" OVERHANGS & 12" RAKES TYP. 8 ROOF VENTS REQUIRED STANDARD ENERGY HEELS @ 4:12 W/ 8:12 FASCIA LINES TO MATCH RAISED HEELS1 ROOF VENTREQUIRED 2 ROOF VENTSREQUIRED 8" / 12"8" / 12"8" / 12"8" / 12"8" / 12"4" / 12"4" / 12"2' - 9"12' - 3"RAISED HEELSRAISED HEELSRAISED HEELSSTANDARD ENERGY HEELS OVER OWNER'S SUITE8" / 12"8" / 12"8" / 12"8" / 12"6" / 12"6" / 12"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:3/16/2022 10:20:47 AMTHE YUSUF RESIDENCEL8, B2 - GLACIER CREEK 2ND ADD'N7067 183RD STREET WESTLAKEVILLE, MN 55044A-202OTT2813.16.22 CB1598145911981.21.22 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4255THE RILEY1/8" = 1'-0"A-2021RIGHT ELEVATION1/8" = 1'-0"A-2022REAR ELEVATION1/8" = 1'-0"A-2023LEFT ELEVATION1/8" = 1'-0"A-2024ROOF PLANSecure door closed until deck isconstructed with a separate permit.
19' - 10"2' - 1 1/2"16' - 3" M.O.2' - 1 1/2"0' - 4 1/2"8' - 3" M.O.1' - 4 1/2"8'-4"(H) x 10"(W) POUREDCONCRETE FOUND. WALL W/4" x 8" EXTERIOR LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.0' - 4"0' - 4"* ALL DIMENSIONS ARE TO EXTERIOR OF CONCRETE, NOT INSULATION1' - 0"12' - 7 1/4"3' - 10 3/4"3' - 10 3/4"17' - 9 1/4"7' - 6 3/4"11' - 9 1/4"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.14' - 0"16' - 0"19' - 0"49' - 0"12' - 0"38' - 2"5' - 10"56' - 0"19' - 4"20' - 6"10' - 0"30' - 6"18' - 6"18' - 4"12' - 0"23' - 8"30' - 4"54' - 0"29' - 8"3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.7'-8"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.* ALL DIMENSIONS ARE TO EXTERIOR OF CONCRETE, NOT INSULATIONSTEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE7' - 9 1/4"15' - 10 3/4"3' - 11 1/4"15' - 10 3/4":LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY, BOTH SIDES.42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY, BOTH SIDES.15' - 3"4' - 1"2' - 0"1' - 10":WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.LEAVE A 12" GAP IN THE FOOTING FOR PLUMBING 4' - 0"1' - 10"STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.11' - 9 3/4"7' - 2 1/4"36" x 36" x 12" CONCRETE FTG.W/ (3) #5 REBAR EACH WAY2' - 0 1/4"8' - 5 1/2"3' - 6 1/4":WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.36" x 36" x 12" CONCRETE FTG.W/ (3) #5 REBAR EACH WAY36" x 36" x 12" CONCRETE FTG.W/ (3) #5 REBAR EACH WAY24' - 5 1/4"5' - 2 3/4"49' - 0"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:3/16/2022 10:20:48 AMTHE YUSUF RESIDENCEL8, B2 - GLACIER CREEK 2ND ADD'N7067 183RD STREET WESTLAKEVILLE, MN 55044A-401OTT2813.16.22 CB1598145911981.21.22 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4255THE RILEY1/4" = 1'-0"A-4011FOUNDATION PLANUFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel.
UP 16RUNEXCAVATEDUNEXCAVATEDSET SILL 6" ABOVE TREATED SILL 3-14" LVL FLUSH0' - 4"2" FOAM INSULATIONBETWEEN WALL & SLAB29' - 8"2x612/4 x 6/8R.O. 2' -6" x 6' -11"42/8 x 6/8R.O. 2' -10" x 6' -11"95/0 x 6/8R.O. 5' -2" x 6' -11"42/8 x 6/8R.O. 2' -10" x 6' -11"R & SH.12/4 x 6/8R.O. 2' -6" x 6' -11"4' VANITY9' - 0"5' - 10"4' - 6"MECHANICALBATHBEDROOM #5FAMILYGAME AREAFURNACEW. H.F. D.SUMPAIR EX.8' - 0"11' - 4"7' - 1 3/4"2' - 0 1/4"31' - 8"17' - 4"0' - 4"16' - 6"21' - 8"5' - 10"38' - 2"12' - 0"56' - 0"19' - 4"CANT. JOIST2' - 0"1' - 10"19' - 10"18' - 4"12' - 0"1' - 0"20' - 6"10' - 0"19' - 6"30' - 6"18' - 6"49' - 0"23' - 8"30' - 4"54' - 0"7' - 9"6' - 3"8' - 0"8' - 0"10' - 0"9' - 0"14' - 0"16' - 0"19' - 0"49' - 0"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.3-11 7/8" LSL W/ 4 TRIMMERS EA. SIDE 2-9 1/2" LSLW/ 4 TRIMMERS 2 TRIMMERS EA. SIDE 2-2x10 DROPPED 3-2x62-2x105x5 PSL5x5 PSLB.W.P.3' - 9"B.W.P.2' - 3"5' - 9"6' - 3"B.W.P.3' - 3"B.W.P.4' - 0"B.W.P.4' - 0"B.W.P.3' - 3"*ALL DIMENSIONS ARE TO OUTSIDE OF CONCRETE/ SHEATHING*ALL DIMENSIONS ARE TO OUTSIDE OF CONCRETE/ SHEATHING2-9 1/2" LSL2 TRIMMERSB.W.P.4' - 0"B.W.P.4' - 0"5' - 9"6' - 3"6' - 0"11' - 4"12' - 10"3' - 8"3' - 8"18' - 0"2-2x10CO DET.SMOKEDET.SMOKEDET.2-2x10 W/2 TRIMMERS2-2x10 W/2 TRIMMERS2-2x10 18" FLOOR TRUSSESPER MFG. SPACING18" FLOOR TRUSSESPER MFG. SPACINGSTEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.4-2x64-2x6424-48-2448 SLR.O. 8' -0" x 4' -0"H.H. 6' -10"146048 SLR.O. 5' -0" x 4' -0"H.H. 6' -10"424-48-2448 SLR.O. 8' -0" x 4' -0"H.H. 6' -10"134848 PICR.O. 4' -0" x 4' -0"H.H. 2' -11 1/4"146048 SLR.O. 5' -0" x 4' -0"H.H. 6' -10"(5) 16" SH.126/0 x 6/8 SLIDERR.O. 6' -0" x 6' -8"32/6 x 6/8R.O. 2' -8" x 6' -11"CLOSET5' TUB/SHWR4' - 0"1' - 10"STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES12' - 8"5' - 4"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:3/16/2022 10:20:49 AMTHE YUSUF RESIDENCEL8, B2 - GLACIER CREEK 2ND ADD'N7067 183RD STREET WESTLAKEVILLE, MN 55044A-402OTT2813.16.22 CB1598145911981.21.22 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4255THE RILEY1/4" = 1'-0"A-4021LOWER FLOOR PLANFAN
UP 17RDN 16RDN 3RDN 3R12' - 0"38' - 0"6' - 0"49' - 0"SINKDWPORCH18' - 6"30' - 6"1' - 6"8' - 0"0' - 6"2' - 3"16' - 0"2' - 3"0' - 10"10' - 8"7' - 2"0' - 10"4" CONCRETE SLAB, SLOPETOWARDS DOORS5/8" TYPE X GYP. BD. ALL COMMONWALLS & CEILINGR-38 MIN. INSULATION IN FLOOR ABOVEGARAGE PLATE HEIGHT TO MATCHMAIN FLOOR UNLESS NOTED OTHERWISE1516' x 8' O.H. GARAGE DOOR56' - 0"19' - 0"16' - 0"14' - 0"GARAGEOVEN /MICRO@ 7' -10" H.H.ABOVE LANDING36" GAS F.P.3' - 0"27' - 0"54' - 0"EQEQFULL HEIGHT RAILING 18' - 0"3' - 8"3' - 8"12' - 8"SEE COLUMN DETAILSHEET A-50120' - 6"10' - 0"49' - 0"17' - 0"3' - 0"LOCKERS.63/0 x 6/8 ARCH4' - 7 1/2"4' - 0"4' - 0"9' - 0"3' - 6"CLOSETPOWDERMUD RM.12/4 x 6/8R.O. 2' -6" x 6' -11"1414" TRANSOM / 6/0 x 6/8SLIDERR.O. 6' -0" x 7' -10"12" B.C.36" PANTRY36" REF36" GASCOOKTOPW/ HOOD2x6 42" TALL WALLW/ WOOD CAPDINING2' - 0"73/0 x 6/8 W/ 12" D.S. SL'S115/0 x 6/8 FULL VIEW W/GRIDSR.O. 6' -2" x 6' -11"2' - 0"9" HEAT DUCT7' - 10"0' - 10"5' - 10"4' - 6"GREAT ROOM10'-1 1/8" CEILING9'-1 1/8" CEILING5' - 6"5' - 6"7' - 0"4' - 11"6' - 3"PED. SINKGIRDER TRUSSKITCHENSTEP IN FLOOR ABOVE 5' - 9"3' - 9"2' - 10"5' - 0"11' - 2"OFFICEFOYER32/6 x 6/8R.O. 2' -8" x 6' -11"R & SH.24" CANT. ABOVE2' - 6"4' - 0"13' - 0"4' - 0"8' - 6"6' - 6"19' - 0"7' - 6"19' - 6"18' - 0"12' - 0"24' - 0"30' - 0"6' - 3"5' - 9"9' - 7"8' - 5"8' - 0"8' - 0"9' - 6"9' - 6"0' - 8" TYP.3' - 0 1/8"12' - 0 1/4"6' - 7 5/8"16' - 4"5' - 6"0' - 6"B.W.P.4' - 0"B.W.P.4' - 0"B.W.P.6' - 0"B.W.P.4' - 0"B.W.P.3' - 3"B.W.P.2' - 9"B.W.P.3' - 3"B.W.P.3' - 6"B.W.P.3' - 6"B.W.P.3' - 3"B.W.P.2' - 9"B.W.P.2' - 9"5' - 9"6' - 3"B.W.P.2' - 9"B.W.P.6' - 3"B.W.P.3' - 0"4' - 0" B.W.P.B.W.P.3' - 6"B.W.P.2' - 9"B.W.P.2' - 0"B.W.P.2' - 3"B.W.P.2' - 3"B.W.P.1' - 6"B.W.P.4' - 0"B.W.P.6' - 3"B.W.P.4' - 0"B.W.P.2' - 3"B.W.P.4' - 0"B.W.P.4' - 0"3-2x65x5 PSL5x5 PSL4-2x64-2x64-2x63-11 7/8" LSL FLUSH3-2x10 2-11 7/8" LSL 2-2x12 2-2x102-9 1/2" LSL2-TRIMMERS2-TRIMMERS5'-0" COUNTERHEIGHT BUFFETTOP QUARTZ/ GRANITE3 ALDER FLOATING SHELVES 2' - 0"PFH BRACED WALL PANEL 3-16" LVL FLUSHRECYCLE 7' - 0"CO DET.SMOKEDET.SMOKEDET.PFH BRACED WALL PANEL 3:123:12FRAME F.P. 12" A.F.F. -3 1/4" CASING THROUGH OUT.-5" NEWEL POST.800# HOLD DOWN2-2x102-2x10 2-2x10 2-2x10 W/2 TRIMMERS2-7 1/4" LSL DROP BEAM2-2x102-2x10 2-2x10 GIRDER TRUSSSTAINED ISLAND20" FLOOR TRUSSESPER MFG. SPACING32" FLOOR TRUSSESPER MFG. SPACING20" FLOOR TRUSSESPER MFG. SPACING20" FLOOR TRUSSESPER MFG. SPACING20" FLOOR TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.2' - 0"2' - 0"4 DISC LIGHTSBEAM VERIFY SIZEHHUS5.50/105x5 PSL5x7 PSL3-2x62-2x10 3-2x6MFG. ROOF TRUSSES@ 24" O.C.36" HIGH BUILT INW/ 2 FLOATING SHELVES36" HIGH BUILT INW/ 2 FLOATING SHELVESPAINTEDTRIM12" A.F.F.DIAGONALPAINTEDSHIPLAP30" HIGH CHAIR RAILW/ PANELS BELOWALL WALLS39"x73" REF. RECESSDBL. FRAMED WALLFOR REFG. RECESS62424 AWN FIXEDR.O. 2' -0" x 2' -0"H.H. 8' -0"62424 AWN FIXEDR.O. 2' -0" x 2' -0"H.H. 8' -0"123660-2W SHR.O. 6' -0" x 5' -0"H.H. 6' -10"15P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"15P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"15P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"116" TRANSOM / 24-48-2460 SLR.O. 8' -0" x 6' -0"H.H. 8' -0"82442 SHR.O. 2' -0" x 3' -6"H.H. 6' -10"216" TRANSOM / 7260 SLR.O. 6' -0" x 6' -4"H.H. 8' -0"8' - 8"5' - 10"138' x 8' O.H. GARAGE DOOR4' - 0"2' - 0"12/4 x 6/8R.O. 2' -6" x 6' -11"R & SH.52/8 x 6/8 FIRE RATEDR.O. 2' -10" x 6' -10 1/4"5' - 8 1/4"134848 PICR.O. 4' -0" x 4' -0"H.H. 12' -6"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES30' - 0"22' - 0"1/4" = 1'-0"A-4031MAIN FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:3/16/2022 10:20:50 AMTHE YUSUF RESIDENCEL8, B2 - GLACIER CREEK 2ND ADD'N7067 183RD STREET WESTLAKEVILLE, MN 55044A-403OTT2813.16.22 CB1598145911981.21.22 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4255THE RILEYVerify loads with girdertruss specs, may requireremoval of top plates atbearing due to crushing.BWPsAboveVerify loads with girdertruss specs, may requireremoval of top plates atbearing due to crushing.
DN 17RDN 2RCO DET.SMOKEDET.SMOKEDET.SMOKEDET.SMOKEDET.SMOKEDET.EN SUITEOWNER'S SUITEBEDROOM #3HALLBEDROOM #414' - 8"3' - 8"3' - 8"18' - 0"4' - 0"7' - 3"26' - 9"2' - 0"38' - 0"18' - 4"21' - 8"32/6 x 6/8R.O. 2' -8" x 6' -11"33' - 8"5' - 10"4' - 6"5' TUB/SHWR32/6 x 6/8R.O. 2' -8" x 6' -11"13' - 0"2' - 4"12/4 x 6/8R.O. 2' -6" x 6' -11"12/4 x 6/8R.O. 2' -6" x 6' -11"SET GLASS PANELON TUB DECKBEDROOM #2LAUNDRYBATHCLOSET32/6 x 6/8R.O. 2' -8" x 6' -11"95/0 x 6/8R.O. 5' -2" x 6' -11"R & SH.42/8 x 6/8R.O. 2' -10" x 6' -11"2x622/4 x 6/8 PKTR.O. 4' -10" x 6' -11"105/0 x 6/8 BFR & SH.2x642/8 x 6/8R.O. 2' -10" x 6' -11"12/4 x 6/8R.O. 2' -6" x 6' -11"48" TALL LINENATTICACCESS(1) SHELF84/0 x 6/8R.O. 4' -2" x 6' -11"12" SH.(5)12/4 x 6/8R.O. 2' -6" x 6' -11"22/4 x 6/8 PKTR.O. 4' -10" x 6' -11"5'-9" VANITYR & SH.R & SH.5' x 3' TUB W/ 6" TILEDECK4' VANITY4' VANITY18" LINEN95/0 x 6/8R.O. 5' -2" x 6' -11"BATHGIRDER TRUSS60" C.T. BASE &WALLS W/SEMI-FRAMLESSDOORR & SH.15' - 11"2' - 7"6' - 9 1/4"6' - 1"4' - 9 3/4"7' - 10"6' - 3"5' - 8"3' - 7 3/4"3' - 2 1/4"4' - 3"1' - 2"5' - 2"14' - 8"9' - 10"4' - 5"6' - 3"3' - 8"9' - 10"6' - 4"5' - 4 1/4"3' - 9 3/4"1' - 7"1' - 7"5' - 6"3' - 10"6' - 0"4' - 0"12' - 0"2' - 8"4' - 10"7' - 3"10' - 5"18' - 10"7' - 6"44' - 0"22' - 9"2' - 3"3' - 3"2' - 9"6' - 6"6' - 6"25' - 0"6' - 0"13' - 0"44' - 0"2-9 1/2" LSL W/ 2 TRIMMERS B.W.P.3' - 0"B.W.P.2' - 3"B.W.P.2' - 3"B.W.P.2' - 3"B.W.P.2' - 3"B.W.P.3' - 0"B.W.P.2' - 3"B.W.P.2' - 3"B.W.P.3' - 0"B.W.P.3' - 0"B.W.P.3' - 0"B.W.P.3' - 0"B.W.P.3' - 0"B.W.P.2' - 3"B.W.P.2' - 3"-3 1/4" CASING THROUGH OUT.-5" NEWEL POST.2x6FULL HEIGHT RAILING 18' - 0"2-2x10 W/2 TRIMMERS2-2x10 2-2x10 2-2x10 2-2x102-2x102-2x10 MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.40' - 0"40' - 0"CO DET.TYP.2' - 0"BOX VAULT3-2x63-2x6HEAD &CONTROL48" F.G. SHWRW/ BYPASSDOOR524-48-2460 SLR.O. 8' -0" x 5' -0"H.H. 6' -10"146048 SLR.O. 5' -0" x 4' -0"H.H. 6' -10"93036 SHR.O. 2' -6" x 3' -0"H.H. 6' -10"113636 PIC TEMP.R.O. 3' -0" x 3' -0"H.H. 6' -10"146048 SLR.O. 5' -0" x 4' -0"H.H. 6' -10"103042 SHR.O. 2' -6" x 3' -6"H.H. 6' -10"123660-2W SHR.O. 6' -0" x 5' -0"H.H. 6' -10"72424-3 AWN FIXEDR.O. 6' -0" x 2' -0"H.H. 6' -10"22/4 x 6/8 PKTR.O. 4' -10" x 6' -11"SINKWASHERDRYERCS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES3'-6" VANITYTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:3/16/2022 10:20:51 AMTHE YUSUF RESIDENCEL8, B2 - GLACIER CREEK 2ND ADD'N7067 183RD STREET WESTLAKEVILLE, MN 55044A-404OTT2813.16.22 CB1598145911981.21.22 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4255THE RILEY1/4" = 1'-0"A-4041UPPER FLOOR PLAN-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).(3)2x10
1' - 5"0' - 9 1/2"2x6 @ BOTTOM1x3 TYP.2x22x4 @ TOPSMOOTH LPSMARTSIDE TYP.SOFFIT1' - 9 1/2"1' - 0"FRONTSIDETOP VEIW1' - 5"0' - 9 1/2"FRAMING4x4 POST9' - 1 1/8"6' - 8"R=1'-7"3' - 0"1' - 4"FASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP.MIN. 3/8" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).MIN. 1000 LB HOLD-DOWNDEVICE (EMBEDDED INTOCONCRETE & NAILEDINTO FRAMING)FRONT ELEVATIONMIN. FOOTING SIZE UNDER OPENING IS12" X 12". A TURNED DOWN SLAB SHALLBE PERMITTED AT DOOR OPENINGS.MIN. (1) 5/8" DIA. ANCHOR BOLDINSTALLED PER R403.1.6 W/2" X 2" X 3/16" PLATE WASHER.MIN. REINFORCING OF FOUNDATION,ONE #4 BAR TOP & BOTTOM OFFOOTING. LAP BARS 15" MINIMUM.MIN. (2) 4200 LB STRAP-TYPE HOLD-DOWNS (EMBEDDED INTO CONCRETEAND NAILED INTO FRAMING)MIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 3/8" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INALL FRAMING (STUDS, BLOCKING AND SILLS) TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED9' - 11 1/4" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTALALL DUCT WORK & PLUMBING TO REMAIN ABOVE INSULATIONTYVEK OR EQUALHOUSE WRAP5/8" TYPE 'X'GYP. BD., TAPE &MUD ALL SEAMS1" RIGID INSULATION3/4" T&G SUBFLOORR-30 MIN.BLOWN INSULATIONFLOOR TRUSSTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:3/16/2022 10:20:52 AMTHE YUSUF RESIDENCEL8, B2 - GLACIER CREEK 2ND ADD'N7067 183RD STREET WESTLAKEVILLE, MN 55044A-501OTT2813.16.22 CB1598145911981.21.22 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4255THE RILEYWINDOW SCHEDULETYPE MARK MANUFACTURER MODEL COUNT UNIT ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT1 WINDSOR NEXT DIMENSION 1 16" TRANSOM / 24-48-2460 SL 8' - 0" 6' - 0" 8' - 0"2 WINDSOR NEXT DIMENSION 1 16" TRANSOM / 7260 SL 6' - 0"6' - 4" 8' - 0"4 WINDSOR NEXT DIMENSION 2 24-48-2448 SL 8' - 0" 4' - 0" 6' - 10"5 WINDSOR NEXT DIMENSION 1 24-48-2460 SL 8' - 0" 5' - 0" 6' - 10"6 WINDSOR NEXT DIMENSION 2 2424 AWN FIXED 2' - 0" 2' - 0"8' - 0"7 WINDSOR NEXT DIMENSION 1 2424-3 AWN FIXED 6' - 0" 2' - 0" 6' - 10"8 WINDSOR NEXT DIMENSION 1 2442 SH 2' - 0" 3' - 6" 6' - 10"9 WINDSOR NEXT DIMENSION 1 3036 SH 2' - 6" 3' - 0" 6' - 10"10 WINDSOR NEXT DIMENSION 1 3042 SH 2' - 6" 3' - 6" 6' - 10"11 WINDSOR NEXT DIMENSION 1 3636 PIC TEMP. 3' - 0" 3' - 0" 6' - 10"12 WINDSOR NEXT DIMENSION 2 3660-2W SH 6' - 0" 5' - 0" 6' - 10"13 WINDSOR NEXT DIMENSION 2 4848 PIC 4' - 0" 4' - 0" VARIES14 WINDSOR NEXT DIMENSION 4 6048 SL 5' - 0" 4' - 0" 6' - 10"15 WINDSOR NEXT DIMENSION 3 P4260/A24 T 3' - 6" 7' - 0" 8' - 0"ROOM FINISH SCHEDULEFLOOR ROOM NAME FLOORING AREA CEILING HEIGHT COMMENTSLOWER FLOOR BEDROOM #5 CARPET 194 SF 8' - 2" .LOWER FLOOR FAMILY CARPET 613 SF 8' - 2" .LOWER FLOOR GAME AREA CARPET 181 SF 8' - 2" .LOWER FLOOR STAIRS CARPET 68 SF 8' - 2"LOWER FLOOR CLOSET CARPET 48 SF 8' - 2" .LOWER FLOOR MECHANICAL CONCRETE 126 SF 8' - 2"LOWER FLOOR BATH VINYL 51 SF 8' - 2" .MAIN FLOOR OFFICE CARPET 121 SF 9' - 1 1/8" .MAIN FLOOR STAIRS CARPET 73 SF 9' - 1 1/8"MAIN FLOOR PORCH CONCRETE 115 SF 9' - 1 1/8" .MAIN FLOOR GARAGE CONCRETE 669 SF 10' - 9 3/8"MAIN FLOOR MUD RM. L.V.T. 75 SF 9' - 1 1/8" .MAIN FLOOR CLOSET VINYL 43 SF 9' - 1 1/8" .MAIN FLOOR POWDER VINYL 27 SF 9' - 1 1/8" .MAIN FLOOR DINING WOOD 173 SF 9' - 1 1/8" VAULTEDMAIN FLOOR GREAT ROOM WOOD 301 SF 10' - 1 1/8" 10'-1 1/8" PLATEMAIN FLOOR KITCHEN WOOD 345 SF 9' - 1 1/8" .MAIN FLOOR FOYER WOOD 149 SF 9' - 1 1/8" .UPPER FLOOR OWNER'S SUITE CARPET 241 SF 8' - 1 1/8" BOX VAULTUPPER FLOOR BEDROOM #3 CARPET 217 SF 8' - 1 1/8" .UPPER FLOOR HALL CARPET 157 SF 8' - 1 1/8"UPPER FLOOR BEDROOM #4 CARPET 161 SF 8' - 1 1/8" .UPPER FLOOR BEDROOM #2 CARPET 203 SF 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 65 SF 8' - 1 1/8" .UPPER FLOOR STAIRS CARPET 72 SF 8' - 1 1/8"UPPER FLOOR EN SUITE TILE 151 SF 8' - 1 1/8" .UPPER FLOOR LAUNDRY VINYL 58 SF 8' - 1 1/8" .UPPER FLOOR BATH VINYL 48 SF 8' - 1 1/8" .UPPER FLOOR BATH VINYL 66 SF 8' - 1 1/8" .DOOR SCHEDULETYPE MARK DOOR SIZE COUNT ROUGH WIDTH ROUGH HEIGHT COMMENTS1 2/4 x 6/8 8 2' - 6" 6' - 11"2 2/4 x 6/8 PKT 3 4' - 10" 6' - 11"3 2/6 x 6/8 5 2' - 8" 6' - 11"4 2/8 x 6/8 4 2' - 10" 6' - 11"5 2/8 x 6/8 FIRE RATED 1 2' - 10" 6' - 10 1/4"6 3/0 x 6/8 ARCH 17 3/0 x 6/8 W/ 12" D.S. SL'S 18 4/0 x 6/8 1 4' - 2" 6' - 11"9 5/0 x 6/8 3 5' - 2" 6' - 11"10 5/0 x 6/8 BF 111 5/0 x 6/8 FULL VIEW W/ GRIDS 1 6' - 2" 6' - 11"12 6/0 x 6/8 SLIDER 1 6' - 0" 6' - 8"13 8' x 8' O.H. GARAGE DOOR 114 14" TRANSOM / 6/0 x 6/8 SLIDER 1 6' - 0" 7' - 10"15 16' x 8' O.H. GARAGE DOOR 11/2" = 1'-0"A-5011TYP. COLUMN1/2" = 1'-0"A-5012ARCH DETAIL3/8" = 1'-0"A-5013METHOD PFH - PORTAL FRAME WITH HOLD-DOWNS1/2" = 1'-0"A-5014GARAGE CEILING
WATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALER6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETRT'D 2x8 SILL PLATEW/ CLOSED CELL ROLLSILL SEALERGRADEGRANULAR FILL4" DRAIN TILEW/ SILT SOCK1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHERE REQUIRED BY CODE)POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR8' - 2"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.VERIFY FLOOR SYSTEMWITH FLOOR PLANSUPPER FLOOR PLATE HEIGHT8' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.3/4" T&GSUBFLOOR6 MIL. V.B.2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.1/2" OSB SHEATHINGTYVEK (OR EQUAL)ROLL HOUSE WRAPSIDING, VERIFYW/ ELEVATIONS5/8" GYP. BD.5/8" GYP. BD.VENTED ALUMINUMSOFFIT PANELSICE & WATER GUARDFROM EAVE TO 2'-0"MIN. OVER STRUCTUREVENT CHUTES & WIND WASH@ EACH TRUSS SPACEASPHALT SHINGLES W/15# ROLL FELT UNDER1/2" OSB ROOF SHEATHINGMFG. ROOFTRUSSES @ 24" O.C.ATTIC VENTINGAS PER CODER-49 MIN. BLOWNATTIC INSULATIONALUMINUM FASCIA W/2x6 SUB FASCIAALUMINUMDRIP EDGERIM JOISTRIM JOISTR-20 MIN. SPRAYFOAM INSULATION,COVER FOUNDATION WALLGMX THERMAL DRAINAGE BOARD(R-10) INSULATIONDRYVIT INSULATIONPROTECTION FROM SIDINGTO 6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITH OUTSIDE OF SHEATINGR-20 MIN. SPRAYFOAM INSULATION6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"5000 PSI CONCRETE@ ALL FOOTINGS2" FOAMBOARD(R-10) INSULATION4" DRAIN TILEW/ SILT SOCKWATER PROOF COATING FROM FOOTING TOSILL SEALERWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESINSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONINSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITHOUTSIDE OF SHEATHINGANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHERE REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" OSBSHEATHINGRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESTOOP, FLASH AS REQ'DAT HOUSE WALLPOUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERSIDING, VERIFYW/ ELEVATIONSTYVEK (OR EQUAL) ROLL HOUSE WRAP0' - 2"FROM SHEATHING TOOUTSIDE OF FOUNDATIONANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHERE REQUIRED BY CODE)18" TOP CHORDBEARING FLOOR TRUSSES,SPACING PER MFG.3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION5/8" TYPE 'X' GYP BOARD,TAPE & MUD ALL SEAMSRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESLAB, FLASH AS REQ'DAT HOUSE WALL0' - 4"POUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALER0' - 8"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.TRT'D SILL PLATEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSSLEEVE EVERY10'-0" MIN.6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODE5000 PSI CONCRETE@ ALL FOOTINGSTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:3/16/2022 10:20:52 AMTHE YUSUF RESIDENCEL8, B2 - GLACIER CREEK 2ND ADD'N7067 183RD STREET WESTLAKEVILLE, MN 55044A-502OTT2813.16.22 CB1598145911981.21.22 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4255THE RILEY3/8" = 1'-0"A-5021TYP. POURED WALL SECTION1/2" = 1'-0"A-5022TYP. POURED WALKOUT SECTION1/2" = 1'-0"A-5023TYP. POURED LOOKOUT SECTION1/2" = 1'-0"A-5024TYP. HOUSE/STOOP WALL1/2" = 1'-0"A-5025TYP. HOUSE/GARAGE WALL1/2" = 1'-0"A-5026BEARING WALL SECTION3" MIN. ABS OR PVC GASTIGHT PIPE FROM SUBSLAB TO MIN.12" ABOVE ROOF, MUST BE RUN THRU CONDITIONED SPACE.PIPE CAN BE CONNECTED TO SUMP SYSTEM OR HAVE"T" FITTING (MIN. 10'-0" EA. WAY) IN GRAVEL UNDER SLAB.END OF PIPE MUST BE MIN. 10'-0" AWAY FROM ANY WINDOW OROTHER OPENING THAT IS LESS THAN 2'-0" BELOW END OF PIPE. END OF PIPE MUST ALSO BE MIN. 10'-0" AWAY FROM ANYWINDOW OR OTHER OPENING IN ADJOINING OR ADJACENT BUILDINGS.SUFFICIENT SPACE MUST BE LEFT AROUND PIPE IN ATTIC SPACETO ADD FAN. SPACE MUST BE MIN. ∅24" CENTERED ON AXIS OFPIPE W/ MIN. 3'-0" VERTICAL SPACE.A SINGLE PIPE CAN BE USED IF ALL SOIL GASES IN DWELLING CANFLOW FREELY BETWEEN ALL LEVELS OF FOUNDATION. THIS INCLUDESINTERIOR FOOTINGS & OTHER BARRIERS IF AIRFLOW HAS BEEN ESTABLISHED.LABEL THE VENT PIPE AT LEAST ONCE PER FLOOR AND IN ACCESSIBLE ATTICSWITH "RADON REDUCTION SYSTEM".ONE ELECTRICAL RECEPTACLE IS REQUIRED IN THE ATTIC NEARTHE VENT PIPE FOR OPT. FAN.:PASSIVE RADON SYSTEM:
R=21018#U=0#R=16935#U=0#R=14350#U=0#R=18077#U=0#R=6879#U=534#R=9713#U=480#K1KG2G1GGGGGH1HHHHHHH2H2H2LJ3J3J3J3MM1KH3N1NNNNNNNNNNNNNNNNN38-00-002-00-0019-00-0016-00-0014-00-0049-00-0012-00-0012-00-0018-00-0024-00-0012-06-00 6-00-00 10-00-0020-06-004-00-005-06-00LO1LO1LO1LO1CD1DEA8A7A6A5A4A3A1AAAAA2A9A10A11A12A13JJJJJJJJJJJJJ2J2J2J2J2J1J1JJJJJJJJHR1EJ2EJ1SJ2SJ1HR1EJ2EJ1SJ2SJ1CG1CJ2CJ1CJ2CJ1V1RV2RV3RV4V5V6Customer: Lyman Lumber - ChanhassenJob Number: 319879-AHome Owner: TOPAZ / RILEY / YUSUF RESJob Name: RoofSite Address: 7067 183RD STREET WEST Sales Rep: Tony StimmlerCity, ST, ZIP: LAKEVILLE MN 55044 Designer: Andy Hoernemann2926 Lone Oak Circle, St. Paul, MN 55121Ph: 651-454-3610 Fax: 651-454-4765Date: 5/11/2022Version: 8.5.3.233
MAIN FLOOR1' -8 1/4"UPPER PLATE20' -7 1/4"T.O. FOUNDATION0' -0"T.O. FOUNDATION0' -0"MAIN PLATE10' -9 3/8"MAIN PLATE10' -9 3/8"UPPER FLOOR12' -6 1/8"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"UPPER FLOOR PLATE HEIGHT8' - 1 1/8"GARAGE PLATE HEIGHT10' - 9 3/8"VINYL FRIEZEBOARD @ FRONT TYP.VINYL SHAKESCULTURED STONEW/ CONCRETE CAPALUMINUM SOFFIT& FASCIA TYP.4' - 0"VINYL CORNER TRIM @ FRONT TYP.6" BUMPED OUT LOUVER W/ CORBELS VINYL BOARD& BATTEN TYP.PLANTER BOX W/ BRACKETS 12" ARCH12" ARCHSEE COLUMN DETAILSHEET A-5010' - 3"ADDRESS STONE 8" 12"4" / 12"4" / 12"8" / 12"8" 12"4" VINYL TRIM @ WINDOWS &DOORS TYP.VINYL LAP @ FRONT TYP.8" 12"1' - 1"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:3/16/2022 10:20:46 AMTHE YUSUF RESIDENCEL8, B2 - GLACIER CREEK 2ND ADD'N7067 183RD STREET WESTLAKEVILLE, MN 55044A-201OTT2813.16.22 CB1598145911981.21.22 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4255THE RILEY1/4" = 1'-0"A-2011FRONT ELEVATIONSHEET INDEXSHEET NUMBER SHEET NAMEA-201 ELEVATIONA-202 ELEVATIONSA-401 FOUNDATIONA-402 LOWER FLOORA-403 MAIN FLOORA-404 UPPER FLOORA-501 SCHEDULES/ DETAILSA-502 DETAILS
24" RETURNS TYP.6" / 12"8" / 12"8" / 12"8" / 12"MAIN FLOOR1' -8 1/4"UPPER PLATE20' -7 1/4"ALUMINUM SOFFIT& FASCIA TYP.VINYL SIDING &CORNERS TYP.GREAT RM. PLATE11' -9 3/8"OWNER'S SUITE FLOOR13' -6 1/8"OWNER'S SUITE PLATE21' -7 1/4"8' - 1 1/8"10' - 1 1/8"8" 12"6" 12"1' - 0"8" / 12"8" 12"8" 12"6" / 12"8" / 12"8" / 12"8" / 12"4" 12"8" 12"STANDARD ENERGY HEELS @ 8:12 & 6:1218" OVERHANGS & 12" RAKES TYP. 8 ROOF VENTS REQUIRED STANDARD ENERGY HEELS @ 4:12 W/ 8:12 FASCIA LINES TO MATCH RAISED HEELS1 ROOF VENTREQUIRED 2 ROOF VENTSREQUIRED 8" / 12"8" / 12"8" / 12"8" / 12"8" / 12"4" / 12"4" / 12"2' - 9"12' - 3"RAISED HEELSRAISED HEELSRAISED HEELSSTANDARD ENERGY HEELS OVER OWNER'S SUITE8" / 12"8" / 12"8" / 12"8" / 12"6" / 12"6" / 12"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:3/16/2022 10:20:47 AMTHE YUSUF RESIDENCEL8, B2 - GLACIER CREEK 2ND ADD'N7067 183RD STREET WESTLAKEVILLE, MN 55044A-202OTT2813.16.22 CB1598145911981.21.22 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4255THE RILEY1/8" = 1'-0"A-2021RIGHT ELEVATION1/8" = 1'-0"A-2022REAR ELEVATION1/8" = 1'-0"A-2023LEFT ELEVATION1/8" = 1'-0"A-2024ROOF PLAN
19' - 10"2' - 1 1/2"16' - 3" M.O.2' - 1 1/2"0' - 4 1/2"8' - 3" M.O.1' - 4 1/2"8'-4"(H) x 10"(W) POUREDCONCRETE FOUND. WALL W/4" x 8" EXTERIOR LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.0' - 4"0' - 4"* ALL DIMENSIONS ARE TO EXTERIOR OF CONCRETE, NOT INSULATION1' - 0"12' - 7 1/4"3' - 10 3/4"3' - 10 3/4"17' - 9 1/4"7' - 6 3/4"11' - 9 1/4"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.14' - 0"16' - 0"19' - 0"49' - 0"12' - 0"38' - 2"5' - 10"56' - 0"19' - 4"20' - 6"10' - 0"30' - 6"18' - 6"18' - 4"12' - 0"23' - 8"30' - 4"54' - 0"29' - 8"3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.7'-8"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.* ALL DIMENSIONS ARE TO EXTERIOR OF CONCRETE, NOT INSULATIONSTEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE7' - 9 1/4"15' - 10 3/4"3' - 11 1/4"15' - 10 3/4":LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY, BOTH SIDES.42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY, BOTH SIDES.15' - 3"4' - 1"2' - 0"1' - 10":WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.LEAVE A 12" GAP IN THE FOOTING FOR PLUMBING 4' - 0"1' - 10"STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.11' - 9 3/4"7' - 2 1/4"36" x 36" x 12" CONCRETE FTG.W/ (3) #5 REBAR EACH WAY2' - 0 1/4"8' - 5 1/2"3' - 6 1/4":WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.36" x 36" x 12" CONCRETE FTG.W/ (3) #5 REBAR EACH WAY36" x 36" x 12" CONCRETE FTG.W/ (3) #5 REBAR EACH WAY24' - 5 1/4"5' - 2 3/4"49' - 0"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:3/16/2022 10:20:48 AMTHE YUSUF RESIDENCEL8, B2 - GLACIER CREEK 2ND ADD'N7067 183RD STREET WESTLAKEVILLE, MN 55044A-401OTT2813.16.22 CB1598145911981.21.22 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4255THE RILEY1/4" = 1'-0"A-4011FOUNDATION PLAN
UP 16RUNEXCAVATEDUNEXCAVATEDSET SILL 6" ABOVE TREATED SILL 3-14" LVL FLUSH0' - 4"2" FOAM INSULATIONBETWEEN WALL & SLAB29' - 8"2x612/4 x 6/8R.O. 2' -6" x 6' -11"42/8 x 6/8R.O. 2' -10" x 6' -11"95/0 x 6/8R.O. 5' -2" x 6' -11"42/8 x 6/8R.O. 2' -10" x 6' -11"R & SH.12/4 x 6/8R.O. 2' -6" x 6' -11"4' VANITY9' - 0"5' - 10"4' - 6"MECHANICALBATHBEDROOM #5FAMILYGAME AREAFURNACEW. H.F. D.SUMPAIR EX.8' - 0"11' - 4"7' - 1 3/4"2' - 0 1/4"31' - 8"17' - 4"0' - 4"16' - 6"21' - 8"5' - 10"38' - 2"12' - 0"56' - 0"19' - 4"CANT. JOIST2' - 0"1' - 10"19' - 10"18' - 4"12' - 0"1' - 0"20' - 6"10' - 0"19' - 6"30' - 6"18' - 6"49' - 0"23' - 8"30' - 4"54' - 0"7' - 9"6' - 3"8' - 0"8' - 0"10' - 0"9' - 0"14' - 0"16' - 0"19' - 0"49' - 0"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.3-11 7/8" LSL W/ 4 TRIMMERS EA. SIDE 2-9 1/2" LSLW/ 4 TRIMMERS 2 TRIMMERS EA. SIDE 2-2x10 DROPPED 3-2x62-2x105x5 PSL5x5 PSLB.W.P.3' - 9"B.W.P.2' - 3"5' - 9"6' - 3"B.W.P.3' - 3"B.W.P.4' - 0"B.W.P.4' - 0"B.W.P.3' - 3"*ALL DIMENSIONS ARE TO OUTSIDE OF CONCRETE/ SHEATHING*ALL DIMENSIONS ARE TO OUTSIDE OF CONCRETE/ SHEATHING2-9 1/2" LSL2 TRIMMERSB.W.P.4' - 0"B.W.P.4' - 0"5' - 9"6' - 3"6' - 0"11' - 4"12' - 10"3' - 8"3' - 8"18' - 0"2-2x10CO DET.SMOKEDET.SMOKEDET.2-2x10 W/2 TRIMMERS2-2x10 W/2 TRIMMERS2-2x10 18" FLOOR TRUSSESPER MFG. SPACING18" FLOOR TRUSSESPER MFG. SPACINGSTEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.4-2x64-2x6424-48-2448 SLR.O. 8' -0" x 4' -0"H.H. 6' -10"146048 SLR.O. 5' -0" x 4' -0"H.H. 6' -10"424-48-2448 SLR.O. 8' -0" x 4' -0"H.H. 6' -10"134848 PICR.O. 4' -0" x 4' -0"H.H. 2' -11 1/4"146048 SLR.O. 5' -0" x 4' -0"H.H. 6' -10"(5) 16" SH.126/0 x 6/8 SLIDERR.O. 6' -0" x 6' -8"32/6 x 6/8R.O. 2' -8" x 6' -11"CLOSET5' TUB/SHWR4' - 0"1' - 10"STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES12' - 8"5' - 4"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:3/16/2022 10:20:49 AMTHE YUSUF RESIDENCEL8, B2 - GLACIER CREEK 2ND ADD'N7067 183RD STREET WESTLAKEVILLE, MN 55044A-402OTT2813.16.22 CB1598145911981.21.22 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4255THE RILEY1/4" = 1'-0"A-4021LOWER FLOOR PLAN
UP 17RDN 16RDN 3RDN 3R12' - 0"38' - 0"6' - 0"49' - 0"SINKDWPORCH18' - 6"30' - 6"1' - 6"8' - 0"0' - 6"2' - 3"16' - 0"2' - 3"0' - 10"10' - 8"7' - 2"0' - 10"4" CONCRETE SLAB, SLOPETOWARDS DOORS5/8" TYPE X GYP. BD. ALL COMMONWALLS & CEILINGR-38 MIN. INSULATION IN FLOOR ABOVEGARAGE PLATE HEIGHT TO MATCHMAIN FLOOR UNLESS NOTED OTHERWISE1516' x 8' O.H. GARAGE DOOR56' - 0"19' - 0"16' - 0"14' - 0"GARAGEOVEN /MICRO@ 7' -10" H.H.ABOVE LANDING36" GAS F.P.3' - 0"27' - 0"54' - 0"EQEQFULL HEIGHT RAILING 18' - 0"3' - 8"3' - 8"12' - 8"SEE COLUMN DETAILSHEET A-50120' - 6"10' - 0"49' - 0"17' - 0"3' - 0"LOCKERS.63/0 x 6/8 ARCH4' - 7 1/2"4' - 0"4' - 0"9' - 0"3' - 6"CLOSETPOWDERMUD RM.12/4 x 6/8R.O. 2' -6" x 6' -11"1414" TRANSOM / 6/0 x 6/8SLIDERR.O. 6' -0" x 7' -10"12" B.C.36" PANTRY36" REF36" GASCOOKTOPW/ HOOD2x6 42" TALL WALLW/ WOOD CAPDINING2' - 0"73/0 x 6/8 W/ 12" D.S. SL'S115/0 x 6/8 FULL VIEW W/GRIDSR.O. 6' -2" x 6' -11"2' - 0"9" HEAT DUCT7' - 10"0' - 10"5' - 10"4' - 6"GREAT ROOM10'-1 1/8" CEILING9'-1 1/8" CEILING5' - 6"5' - 6"7' - 0"4' - 11"6' - 3"PED. SINKGIRDER TRUSSKITCHENSTEP IN FLOOR ABOVE 5' - 9"3' - 9"2' - 10"5' - 0"11' - 2"OFFICEFOYER32/6 x 6/8R.O. 2' -8" x 6' -11"R & SH.24" CANT. ABOVE2' - 6"4' - 0"13' - 0"4' - 0"8' - 6"6' - 6"19' - 0"7' - 6"19' - 6"18' - 0"12' - 0"24' - 0"30' - 0"6' - 3"5' - 9"9' - 7"8' - 5"8' - 0"8' - 0"9' - 6"9' - 6"0' - 8" TYP.3' - 0 1/8"12' - 0 1/4"6' - 7 5/8"16' - 4"5' - 6"0' - 6"B.W.P.4' - 0"B.W.P.4' - 0"B.W.P.6' - 0"B.W.P.4' - 0"B.W.P.3' - 3"B.W.P.2' - 9"B.W.P.3' - 3"B.W.P.3' - 6"B.W.P.3' - 6"B.W.P.3' - 3"B.W.P.2' - 9"B.W.P.2' - 9"5' - 9"6' - 3"B.W.P.2' - 9"B.W.P.6' - 3"B.W.P.3' - 0"4' - 0" B.W.P.B.W.P.3' - 6"B.W.P.2' - 9"B.W.P.2' - 0"B.W.P.2' - 3"B.W.P.2' - 3"B.W.P.1' - 6"B.W.P.4' - 0"B.W.P.6' - 3"B.W.P.4' - 0"B.W.P.2' - 3"B.W.P.4' - 0"B.W.P.4' - 0"3-2x65x5 PSL5x5 PSL4-2x64-2x64-2x63-11 7/8" LSL FLUSH3-2x10 2-11 7/8" LSL 2-2x12 2-2x102-9 1/2" LSL2-TRIMMERS2-TRIMMERS5'-0" COUNTERHEIGHT BUFFETTOP QUARTZ/ GRANITE3 ALDER FLOATING SHELVES 2' - 0"PFH BRACED WALL PANEL 3-16" LVL FLUSHRECYCLE 7' - 0"CO DET.SMOKEDET.SMOKEDET.PFH BRACED WALL PANEL 3:123:12FRAME F.P. 12" A.F.F. -3 1/4" CASING THROUGH OUT.-5" NEWEL POST.800# HOLD DOWN2-2x102-2x10 2-2x10 2-2x10 W/2 TRIMMERS2-7 1/4" LSL DROP BEAM2-2x102-2x10 2-2x10 GIRDER TRUSSSTAINED ISLAND20" FLOOR TRUSSESPER MFG. SPACING32" FLOOR TRUSSESPER MFG. SPACING20" FLOOR TRUSSESPER MFG. SPACING20" FLOOR TRUSSESPER MFG. SPACING20" FLOOR TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.2' - 0"2' - 0"4 DISC LIGHTSBEAM VERIFY SIZEHHUS5.50/105x5 PSL5x7 PSL3-2x62-2x10 3-2x6MFG. ROOF TRUSSES@ 24" O.C.36" HIGH BUILT INW/ 2 FLOATING SHELVES36" HIGH BUILT INW/ 2 FLOATING SHELVESPAINTEDTRIM12" A.F.F.DIAGONALPAINTEDSHIPLAP30" HIGH CHAIR RAILW/ PANELS BELOWALL WALLS39"x73" REF. RECESSDBL. FRAMED WALLFOR REFG. RECESS62424 AWN FIXEDR.O. 2' -0" x 2' -0"H.H. 8' -0"62424 AWN FIXEDR.O. 2' -0" x 2' -0"H.H. 8' -0"123660-2W SHR.O. 6' -0" x 5' -0"H.H. 6' -10"15P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"15P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"15P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"116" TRANSOM / 24-48-2460 SLR.O. 8' -0" x 6' -0"H.H. 8' -0"82442 SHR.O. 2' -0" x 3' -6"H.H. 6' -10"216" TRANSOM / 7260 SLR.O. 6' -0" x 6' -4"H.H. 8' -0"8' - 8"5' - 10"138' x 8' O.H. GARAGE DOOR4' - 0"2' - 0"12/4 x 6/8R.O. 2' -6" x 6' -11"R & SH.52/8 x 6/8 FIRE RATEDR.O. 2' -10" x 6' -10 1/4"5' - 8 1/4"134848 PICR.O. 4' -0" x 4' -0"H.H. 12' -6"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES30' - 0"22' - 0"1/4" = 1'-0"A-4031MAIN FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:3/16/2022 10:20:50 AMTHE YUSUF RESIDENCEL8, B2 - GLACIER CREEK 2ND ADD'N7067 183RD STREET WESTLAKEVILLE, MN 55044A-403OTT2813.16.22 CB1598145911981.21.22 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4255THE RILEY
DN 17RDN 2RCO DET.SMOKEDET.SMOKEDET.SMOKEDET.SMOKEDET.SMOKEDET.EN SUITEOWNER'S SUITEBEDROOM #3HALLBEDROOM #414' - 8"3' - 8"3' - 8"18' - 0"4' - 0"7' - 3"26' - 9"2' - 0"38' - 0"18' - 4"21' - 8"32/6 x 6/8R.O. 2' -8" x 6' -11"33' - 8"5' - 10"4' - 6"5' TUB/SHWR32/6 x 6/8R.O. 2' -8" x 6' -11"13' - 0"2' - 4"12/4 x 6/8R.O. 2' -6" x 6' -11"12/4 x 6/8R.O. 2' -6" x 6' -11"SET GLASS PANELON TUB DECKBEDROOM #2LAUNDRYBATHCLOSET32/6 x 6/8R.O. 2' -8" x 6' -11"95/0 x 6/8R.O. 5' -2" x 6' -11"R & SH.42/8 x 6/8R.O. 2' -10" x 6' -11"2x622/4 x 6/8 PKTR.O. 4' -10" x 6' -11"105/0 x 6/8 BFR & SH.2x642/8 x 6/8R.O. 2' -10" x 6' -11"12/4 x 6/8R.O. 2' -6" x 6' -11"48" TALL LINENATTICACCESS(1) SHELF84/0 x 6/8R.O. 4' -2" x 6' -11"12" SH.(5)12/4 x 6/8R.O. 2' -6" x 6' -11"22/4 x 6/8 PKTR.O. 4' -10" x 6' -11"5'-9" VANITYR & SH.R & SH.5' x 3' TUB W/ 6" TILEDECK4' VANITY4' VANITY18" LINEN95/0 x 6/8R.O. 5' -2" x 6' -11"BATHGIRDER TRUSS60" C.T. BASE &WALLS W/SEMI-FRAMLESSDOORR & SH.15' - 11"2' - 7"6' - 9 1/4"6' - 1"4' - 9 3/4"7' - 10"6' - 3"5' - 8"3' - 7 3/4"3' - 2 1/4"4' - 3"1' - 2"5' - 2"14' - 8"9' - 10"4' - 5"6' - 3"3' - 8"9' - 10"6' - 4"5' - 4 1/4"3' - 9 3/4"1' - 7"1' - 7"5' - 6"3' - 10"6' - 0"4' - 0"12' - 0"2' - 8"4' - 10"7' - 3"10' - 5"18' - 10"7' - 6"44' - 0"22' - 9"2' - 3"3' - 3"2' - 9"6' - 6"6' - 6"25' - 0"6' - 0"13' - 0"44' - 0"2-9 1/2" LSL W/ 2 TRIMMERS B.W.P.3' - 0"B.W.P.2' - 3"B.W.P.2' - 3"B.W.P.2' - 3"B.W.P.2' - 3"B.W.P.3' - 0"B.W.P.2' - 3"B.W.P.2' - 3"B.W.P.3' - 0"B.W.P.3' - 0"B.W.P.3' - 0"B.W.P.3' - 0"B.W.P.3' - 0"B.W.P.2' - 3"B.W.P.2' - 3"-3 1/4" CASING THROUGH OUT.-5" NEWEL POST.2x6FULL HEIGHT RAILING 18' - 0"2-2x10 W/2 TRIMMERS2-2x10 2-2x10 2-2x10 2-2x102-2x102-2x10 MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.40' - 0"40' - 0"CO DET.TYP.2' - 0"BOX VAULT3-2x63-2x6HEAD &CONTROL48" F.G. SHWRW/ BYPASSDOOR524-48-2460 SLR.O. 8' -0" x 5' -0"H.H. 6' -10"146048 SLR.O. 5' -0" x 4' -0"H.H. 6' -10"93036 SHR.O. 2' -6" x 3' -0"H.H. 6' -10"113636 PIC TEMP.R.O. 3' -0" x 3' -0"H.H. 6' -10"146048 SLR.O. 5' -0" x 4' -0"H.H. 6' -10"103042 SHR.O. 2' -6" x 3' -6"H.H. 6' -10"123660-2W SHR.O. 6' -0" x 5' -0"H.H. 6' -10"72424-3 AWN FIXEDR.O. 6' -0" x 2' -0"H.H. 6' -10"22/4 x 6/8 PKTR.O. 4' -10" x 6' -11"SINKWASHERDRYERCS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES3'-6" VANITYTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:3/16/2022 10:20:51 AMTHE YUSUF RESIDENCEL8, B2 - GLACIER CREEK 2ND ADD'N7067 183RD STREET WESTLAKEVILLE, MN 55044A-404OTT2813.16.22 CB1598145911981.21.22 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4255THE RILEY1/4" = 1'-0"A-4041UPPER FLOOR PLANHipset GirderHipset Girder3-2x10
1' - 5"0' - 9 1/2"2x6 @ BOTTOM1x3 TYP.2x22x4 @ TOPSMOOTH LPSMARTSIDE TYP.SOFFIT1' - 9 1/2"1' - 0"FRONTSIDETOP VEIW1' - 5"0' - 9 1/2"FRAMING4x4 POST9' - 1 1/8"6' - 8"R=1'-7"3' - 0"1' - 4"FASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP.MIN. 3/8" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).MIN. 1000 LB HOLD-DOWNDEVICE (EMBEDDED INTOCONCRETE & NAILEDINTO FRAMING)FRONT ELEVATIONMIN. FOOTING SIZE UNDER OPENING IS12" X 12". A TURNED DOWN SLAB SHALLBE PERMITTED AT DOOR OPENINGS.MIN. (1) 5/8" DIA. ANCHOR BOLDINSTALLED PER R403.1.6 W/2" X 2" X 3/16" PLATE WASHER.MIN. REINFORCING OF FOUNDATION,ONE #4 BAR TOP & BOTTOM OFFOOTING. LAP BARS 15" MINIMUM.MIN. (2) 4200 LB STRAP-TYPE HOLD-DOWNS (EMBEDDED INTO CONCRETEAND NAILED INTO FRAMING)MIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 3/8" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INALL FRAMING (STUDS, BLOCKING AND SILLS) TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED9' - 11 1/4" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTALALL DUCT WORK & PLUMBING TO REMAIN ABOVE INSULATIONTYVEK OR EQUALHOUSE WRAP5/8" TYPE 'X'GYP. BD., TAPE &MUD ALL SEAMS1" RIGID INSULATION3/4" T&G SUBFLOORR-30 MIN.BLOWN INSULATIONFLOOR TRUSSTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:3/16/2022 10:20:52 AMTHE YUSUF RESIDENCEL8, B2 - GLACIER CREEK 2ND ADD'N7067 183RD STREET WESTLAKEVILLE, MN 55044A-501OTT2813.16.22 CB1598145911981.21.22 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4255THE RILEYWINDOW SCHEDULETYPE MARK MANUFACTURER MODEL COUNT UNIT ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT1 WINDSOR NEXT DIMENSION 1 16" TRANSOM / 24-48-2460 SL 8' - 0" 6' - 0" 8' - 0"2 WINDSOR NEXT DIMENSION 1 16" TRANSOM / 7260 SL 6' - 0"6' - 4" 8' - 0"4 WINDSOR NEXT DIMENSION 2 24-48-2448 SL 8' - 0" 4' - 0" 6' - 10"5 WINDSOR NEXT DIMENSION 1 24-48-2460 SL 8' - 0" 5' - 0" 6' - 10"6 WINDSOR NEXT DIMENSION 2 2424 AWN FIXED 2' - 0" 2' - 0"8' - 0"7 WINDSOR NEXT DIMENSION 1 2424-3 AWN FIXED 6' - 0" 2' - 0" 6' - 10"8 WINDSOR NEXT DIMENSION 1 2442 SH 2' - 0" 3' - 6" 6' - 10"9 WINDSOR NEXT DIMENSION 1 3036 SH 2' - 6" 3' - 0" 6' - 10"10 WINDSOR NEXT DIMENSION 1 3042 SH 2' - 6" 3' - 6" 6' - 10"11 WINDSOR NEXT DIMENSION 1 3636 PIC TEMP. 3' - 0" 3' - 0" 6' - 10"12 WINDSOR NEXT DIMENSION 2 3660-2W SH 6' - 0" 5' - 0" 6' - 10"13 WINDSOR NEXT DIMENSION 2 4848 PIC 4' - 0" 4' - 0" VARIES14 WINDSOR NEXT DIMENSION 4 6048 SL 5' - 0" 4' - 0" 6' - 10"15 WINDSOR NEXT DIMENSION 3 P4260/A24 T 3' - 6" 7' - 0" 8' - 0"ROOM FINISH SCHEDULEFLOOR ROOM NAME FLOORING AREA CEILING HEIGHT COMMENTSLOWER FLOOR BEDROOM #5 CARPET 194 SF 8' - 2" .LOWER FLOOR FAMILY CARPET 613 SF 8' - 2" .LOWER FLOOR GAME AREA CARPET 181 SF 8' - 2" .LOWER FLOOR STAIRS CARPET 68 SF 8' - 2"LOWER FLOOR CLOSET CARPET 48 SF 8' - 2" .LOWER FLOOR MECHANICAL CONCRETE 126 SF 8' - 2"LOWER FLOOR BATH VINYL 51 SF 8' - 2" .MAIN FLOOR OFFICE CARPET 121 SF 9' - 1 1/8" .MAIN FLOOR STAIRS CARPET 73 SF 9' - 1 1/8"MAIN FLOOR PORCH CONCRETE 115 SF 9' - 1 1/8" .MAIN FLOOR GARAGE CONCRETE 669 SF 10' - 9 3/8"MAIN FLOOR MUD RM. L.V.T. 75 SF 9' - 1 1/8" .MAIN FLOOR CLOSET VINYL 43 SF 9' - 1 1/8" .MAIN FLOOR POWDER VINYL 27 SF 9' - 1 1/8" .MAIN FLOOR DINING WOOD 173 SF 9' - 1 1/8" VAULTEDMAIN FLOOR GREAT ROOM WOOD 301 SF 10' - 1 1/8" 10'-1 1/8" PLATEMAIN FLOOR KITCHEN WOOD 345 SF 9' - 1 1/8" .MAIN FLOOR FOYER WOOD 149 SF 9' - 1 1/8" .UPPER FLOOR OWNER'S SUITE CARPET 241 SF 8' - 1 1/8" BOX VAULTUPPER FLOOR BEDROOM #3 CARPET 217 SF 8' - 1 1/8" .UPPER FLOOR HALL CARPET 157 SF 8' - 1 1/8"UPPER FLOOR BEDROOM #4 CARPET 161 SF 8' - 1 1/8" .UPPER FLOOR BEDROOM #2 CARPET 203 SF 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 65 SF 8' - 1 1/8" .UPPER FLOOR STAIRS CARPET 72 SF 8' - 1 1/8"UPPER FLOOR EN SUITE TILE 151 SF 8' - 1 1/8" .UPPER FLOOR LAUNDRY VINYL 58 SF 8' - 1 1/8" .UPPER FLOOR BATH VINYL 48 SF 8' - 1 1/8" .UPPER FLOOR BATH VINYL 66 SF 8' - 1 1/8" .DOOR SCHEDULETYPE MARK DOOR SIZE COUNT ROUGH WIDTH ROUGH HEIGHT COMMENTS1 2/4 x 6/8 8 2' - 6" 6' - 11"2 2/4 x 6/8 PKT 3 4' - 10" 6' - 11"3 2/6 x 6/8 5 2' - 8" 6' - 11"4 2/8 x 6/8 4 2' - 10" 6' - 11"5 2/8 x 6/8 FIRE RATED 1 2' - 10" 6' - 10 1/4"6 3/0 x 6/8 ARCH 17 3/0 x 6/8 W/ 12" D.S. SL'S 18 4/0 x 6/8 1 4' - 2" 6' - 11"9 5/0 x 6/8 3 5' - 2" 6' - 11"10 5/0 x 6/8 BF 111 5/0 x 6/8 FULL VIEW W/ GRIDS 1 6' - 2" 6' - 11"12 6/0 x 6/8 SLIDER 1 6' - 0" 6' - 8"13 8' x 8' O.H. GARAGE DOOR 114 14" TRANSOM / 6/0 x 6/8 SLIDER 1 6' - 0" 7' - 10"15 16' x 8' O.H. GARAGE DOOR 11/2" = 1'-0"A-5011TYP. COLUMN1/2" = 1'-0"A-5012ARCH DETAIL3/8" = 1'-0"A-5013METHOD PFH - PORTAL FRAME WITH HOLD-DOWNS1/2" = 1'-0"A-5014GARAGE CEILING
WATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALER6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETRT'D 2x8 SILL PLATEW/ CLOSED CELL ROLLSILL SEALERGRADEGRANULAR FILL4" DRAIN TILEW/ SILT SOCK1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHERE REQUIRED BY CODE)POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR8' - 2"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.VERIFY FLOOR SYSTEMWITH FLOOR PLANSUPPER FLOOR PLATE HEIGHT8' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.3/4" T&GSUBFLOOR6 MIL. V.B.2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.1/2" OSB SHEATHINGTYVEK (OR EQUAL)ROLL HOUSE WRAPSIDING, VERIFYW/ ELEVATIONS5/8" GYP. BD.5/8" GYP. BD.VENTED ALUMINUMSOFFIT PANELSICE & WATER GUARDFROM EAVE TO 2'-0"MIN. OVER STRUCTUREVENT CHUTES & WIND WASH@ EACH TRUSS SPACEASPHALT SHINGLES W/15# ROLL FELT UNDER1/2" OSB ROOF SHEATHINGMFG. ROOFTRUSSES @ 24" O.C.ATTIC VENTINGAS PER CODER-49 MIN. BLOWNATTIC INSULATIONALUMINUM FASCIA W/2x6 SUB FASCIAALUMINUMDRIP EDGERIM JOISTRIM JOISTR-20 MIN. SPRAYFOAM INSULATION,COVER FOUNDATION WALLGMX THERMAL DRAINAGE BOARD(R-10) INSULATIONDRYVIT INSULATIONPROTECTION FROM SIDINGTO 6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITH OUTSIDE OF SHEATINGR-20 MIN. SPRAYFOAM INSULATION6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"5000 PSI CONCRETE@ ALL FOOTINGS2" FOAMBOARD(R-10) INSULATION4" DRAIN TILEW/ SILT SOCKWATER PROOF COATING FROM FOOTING TOSILL SEALERWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESINSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONINSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITHOUTSIDE OF SHEATHINGANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHERE REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" OSBSHEATHINGRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESTOOP, FLASH AS REQ'DAT HOUSE WALLPOUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERSIDING, VERIFYW/ ELEVATIONSTYVEK (OR EQUAL) ROLL HOUSE WRAP0' - 2"FROM SHEATHING TOOUTSIDE OF FOUNDATIONANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHERE REQUIRED BY CODE)18" TOP CHORDBEARING FLOOR TRUSSES,SPACING PER MFG.3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION5/8" TYPE 'X' GYP BOARD,TAPE & MUD ALL SEAMSRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESLAB, FLASH AS REQ'DAT HOUSE WALL0' - 4"POUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALER0' - 8"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.TRT'D SILL PLATEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSSLEEVE EVERY10'-0" MIN.6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODE5000 PSI CONCRETE@ ALL FOOTINGSTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:3/16/2022 10:20:52 AMTHE YUSUF RESIDENCEL8, B2 - GLACIER CREEK 2ND ADD'N7067 183RD STREET WESTLAKEVILLE, MN 55044A-502OTT2813.16.22 CB1598145911981.21.22 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4255THE RILEY3/8" = 1'-0"A-5021TYP. POURED WALL SECTION1/2" = 1'-0"A-5022TYP. POURED WALKOUT SECTION1/2" = 1'-0"A-5023TYP. POURED LOOKOUT SECTION1/2" = 1'-0"A-5024TYP. HOUSE/STOOP WALL1/2" = 1'-0"A-5025TYP. HOUSE/GARAGE WALL1/2" = 1'-0"A-5026BEARING WALL SECTION3" MIN. ABS OR PVC GASTIGHT PIPE FROM SUBSLAB TO MIN.12" ABOVE ROOF, MUST BE RUN THRU CONDITIONED SPACE.PIPE CAN BE CONNECTED TO SUMP SYSTEM OR HAVE"T" FITTING (MIN. 10'-0" EA. WAY) IN GRAVEL UNDER SLAB.END OF PIPE MUST BE MIN. 10'-0" AWAY FROM ANY WINDOW OROTHER OPENING THAT IS LESS THAN 2'-0" BELOW END OF PIPE. END OF PIPE MUST ALSO BE MIN. 10'-0" AWAY FROM ANYWINDOW OR OTHER OPENING IN ADJOINING OR ADJACENT BUILDINGS.SUFFICIENT SPACE MUST BE LEFT AROUND PIPE IN ATTIC SPACETO ADD FAN. SPACE MUST BE MIN. ∅24" CENTERED ON AXIS OFPIPE W/ MIN. 3'-0" VERTICAL SPACE.A SINGLE PIPE CAN BE USED IF ALL SOIL GASES IN DWELLING CANFLOW FREELY BETWEEN ALL LEVELS OF FOUNDATION. THIS INCLUDESINTERIOR FOOTINGS & OTHER BARRIERS IF AIRFLOW HAS BEEN ESTABLISHED.LABEL THE VENT PIPE AT LEAST ONCE PER FLOOR AND IN ACCESSIBLE ATTICSWITH "RADON REDUCTION SYSTEM".ONE ELECTRICAL RECEPTACLE IS REQUIRED IN THE ATTIC NEARTHE VENT PIPE FOR OPT. FAN.:PASSIVE RADON SYSTEM:
NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION
This form must be completed and submitted with all new residential permit applications.
New residential building permits WILL NOT be issued without this completed form.
Project Site Address: _____________________________________________________________________
Company Name: _________________________________________________________________________
Primary Contact: _________________________________________________________________________
Phone # (24 hr Contact): ______________________ Email: ______________________________________
Description of Land Disturbing Activity: _____________________________________________________
NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___
If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an
erosion and sediment control plan MUST be submitted with the residential building permit application.
Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control
inspections and corrective actions:
Name of Person: ________________________________Company: _______________________________
Phone # (24 hr Contact): ______________________ Email: ______________________________________
Entity that Provided Training: ________________________ Certification Expiration Date: ____________
NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots.
No land disturbing activity may begin until a residential building permit has been issued.
I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National
Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER;
withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater
Permit (MN R 100001) or erosion and sediment control plan.
Signature: ________________________________________________ Date:_________________________
Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500
* If awaiting a MPCA permit transfer, provide MPCA proof of transfer submittal e-mail along with this form to
erosion@lakevillemn.gov
“The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.” (NPDES Construction Stormwater Permit, MPCA)
“The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA)
4/29/22 Y