HomeMy WebLinkAboutLA201921-Approved Justin Furlong Solar Drawings wStamp 05 12 2022 (1)EXISTINGSNAPNRACKSITE MAP & PV LAYOUTELECTRICAL 1-LINE DIAGRAM ATTACHMENT LAYOUTSYSTEM LABELING DETAILENPHASE RAPID SHUTDOWNINVERTER DATA SHEETSHEET INDEXPROPERTY PLANMODULE DATA SHEETRACKING DATA SHEETATTACHMENT DATA SHEETPV 1.0PV 2.0PV 4.0PV 5.1D 6.0D 7.0D 8.0D 9.0D 10.0D 11.0SYSTEM RATINGEQUIPMENT SUMMARYELECTRICAL INFORMATIONMAIN SERVICE PANEL BUS SIZE:MAIN SERVICE BREAKER SIZE:MOUNTING SYSTEM:BUILDING INFORMATIONCONSTRUCTION TYPE: V-BOCCUPANCY: R3ROOF:Truss 2 x 4 @ 24" O.C.Comp ShingleVICINITY MAP (SCALE: NTS)SATELLITE VIEW (SCALE: NTS)GENERAL NOTES1.All electrical materials shall be new and listed by recognizedelectrical testing laboratory Custom made equipment shall have complete test data submittedby the manufacturer attesting to its safety2.Outdoor equipment shall be NEMA 3R rated or equivalent3.All metallic equipment shall be grounded4.Contractor shall obtain electrical permits prior to installation andshall coordinate all inspections, testing commissioning andacceptance with the client, utility co. and city inspectors as needed.5.The electrical contractor shall verify the exact locations of servicepoints and service sizes with the serving utility company andcomply with all utility companies requirements.6.Drawings are diagrammatic only, routing of raceways shall beoption of the contractor unless otherwise noted and shall becoordinated with other trades.7.If the roof material or the roof structure not adequate for PVinstallation, call the engineer of record print to installation. Thecontractor is responsible to verify that the roof is capable ofwithstanding the extra weight.8.If the distances for cable runs are different than shown, thecontractor shall notify the electrical engineer to validate the wiresize. Final drawings will be red-lined and updated as appropriate.9.Whenever a discrepancy in quality of equipment arises on thedrawing or specifications, the contractor shall be responsible forproviding and installing all materials and services required by thestrictest conditions noted on the drawings or in the specificationsto ensure complete compliance and longevity of the operablesystem required by the engineer of record.PHOTOVOLTAIC NOTES:1.Rooftop mounted photovoltaic panels and modules shall be tested,listed and identified by recognized testing laboratory2.Solar system shall not cover any plumbing or mechanical vents3.Modules and support structures shall be grounded unless racking has integrated ground.4.Removal of an interactive inverter or other equipment shall notdisconnect the bonding connection between the groundingelectrode conductor and the photovoltaic source and/or outputcircuit grounded conductors.5.All PV modules and associated equipment and wiring shall beprotected from physical damage.6.Live parts of PV source circuits and PV output circuits over 150v toground shall not be accessible to other than qualified persons while energized.7.Inverter is equipped with integrated DC disconnect, thus providingground fault protection8.All conductors shall be copper and 75 deg rated9.A single conductor shall be permitted to be used to perform themultiple functions of dc grounding, AC grounding and bondingbetween AC and DC systems.10.Non-current carrying metal parts of equipment shall be effectivelybonded together. Bond both ends of raceways.200A200A05/12/2022Property Address:Owner:Justin FurlongProperty Type:Single Family ResidenceDrawn by:New@engineerinc.ioDate: HANWHA 400 WATT MODULESWITH IQ8+ MICROINVERTERS17953 Fulda Trail Farmington, MN 55024CONTRACTORAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comTHE INSTALLATION OF SOLAR ARRAYS ANDPHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITHTHE FOLLOWING CODES:·2020 National Electrical Code·2018 International Building Code·2018 International Residential Code·2020 Minnesota Residential Code·2020 Minnesota Building Code·2020 Minnesota Energy Code·2020 Minnesota Accessibility Code·2020 Minnesota State Fire Code·2018 International Fire Code·2018 International Energy Conservation Code·2018 Mechanical CodeAS ADOPTED BY THE STATE OF MINNESOTAALL OTHER ORDINANCE ADOPTED BY THELOCAL GOVERNING AGENCIESGOVERNING CODESINVERTER CERTIFICATIOND 13.0PV 3.1ENPHASE AC COMBINER BOXD 12.0PV INSPECTION CHECKLIST ATTACHMENT DETAILPV 5.2SURGE PROTECTIOND 14.0PLACARDPV 3.2DC 11.20 KW STCAC 8.12 KW STC28Date Certified andSigned: 05/12/2022 EMT type ConduitSolar Module(N) Junction BoxJB.................................................................................MSP(E) Main Service Panel200AINDEXAC.................... (N) 60A Utility AC(N) MicroinverterNOTE: Conduit in attic shallbe minimum 18 inches from roof sheatingSITE MAP & PVLAYOUTPV 1.0PV SYSTEMAS INDICATEDScale:Project:Drawn by:New@engineerinc.ioProject Name:Property Adress:05/12/2022Justin Furlong17953 Fulda TrailFarmington, MN 55024DATE:CONTRACTORECB(N) Enphase Combiner Box....Wolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comNote: 24/ 7 Unescorted keyless access is to beprovided for ALL UTILITY EQUIPMENTNOTE: No clearance issue Distance between all equipments is maximum 10"(E) Main MeterMM........................Fire Setback Line.............SECONDARY INTERCONNECTIONFMT type Conduit.............SOLAR MODULES___HANWHA 400 WattModel #Q.PEAK DUO BLK ML-G10+2828INVERTERINVERTER TYPE: Micro:___ Enphase IQ8PLUSModel # IQ8PLUS-72-2-US(240V) Dakota ElectricEQUIPMENT ELEVATIONECB ACDisconnect4'10"From roofMainServicePanel<10"10"PerformanceMeter(N) Performance MeterPM.............Total Roof Area: 5398Total Module Area:61611.41% of CoverageMainMeterOutsideInsideInsideOutside Fulda Trail18" fire setback18" fire setback36" fire setbackMSPMMPMACECBaaaaaaaaaabbbbbbbbbcccccccccJB1JB2JB3Solar PV Array 119-Hanwha 400 W Modules19 - IQ8+ MicroinvertersPitch:30 DegOrientation: 192 DegSolar PV Array 27-Hanwha 400 W Modules7 - IQ8+ MicroinvertersPitch:34 DegOrientation: 192 DegSolar PV Array 32-Hanwha 400 W Modules2 - IQ8+ MicroinvertersPitch:34 DegOrientation: 192 DegSCALE:1/16" = 1'-0" 180° 90° 270°0°SWNE (3) #6 AWG THWN/THWN-23/4" EMT, 2 FEETENPHASE Q CABLE(2) #12 AWG PV WIRE(1) #6 AWG EGCFREE IN THE AIRPV 2.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Justin Furlong17953 Fulda TrailFarmington, MN 55024ELECTRICAL 1-LINE DIAGRAMCONTRACTOREnphasePV MONITORING DEVICEENPHASE AC COMBINER BOX120/240V, 1P,3W NEMA 3R(2) #14 AWG THWN/ THWN-210A 2-POLENote: 24/ 7 Unescorted keyless access is to beprovided for ALL UTILITY EQUIPMENT In locations where there is no local Public Authority, the customer is exempt frominspection, and/or the service has been shut off or disconnected for more than 365 days (1 year),the licensed electrician or wireman shall submit a signed and datedElectrical Inspection Certificate to the Company’s Builders Call Line attesting that the electrical installationhas been completed and installed according to the current National Electrical Code®, theStandard for Electric Installation and Use, and any other applicable codes that apply beforeelectric service is energized.Design meet National Electric Code(NEC codes)For smaller DERs, using the PoC as theReference Point of Applicability allows the DERequipment type testing certification to be utilizedas the main method by which compliancewith the Standard is verified. The PoC might bethe terminals of an inverter, for example,and utilizing a UL 1741 certified and listed inverterwould be sufficient to demonstrateStandard compliance.60A FUSED AC DISCONNECT,WITH 50A FUSES UTILTY AC DISCONNECT VISIBLE-OPENLOCKABLE, READILY ACCESSIBLENEMA3R120 / 240V 1P,3WINSTALL (3)20A PV2-POLE C/BWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com EXISTING______ MAINSERVICEPANEL120/240V,1P, 3WGEC(E) GROUNDINGELECTRODE SYSTEM200ANON CENTER _____MAIN C/BNOTE: Service Panel does not contain center fed Main Breaker:SECONDARY INTERCONNECTIONREFERENCE POINT OF APPLICABILITY12.1A (6) #10 AWG THWN/THWN-2 (1) #8 AWG GND 3/4'' EMT, 7 FEETAtticWall (6) #10 AWG THWN/THWN-2 (1) #8 AWG GND 3/4'' FMT, 20 FEETSurge ProtectionMNSPD-300-ACDrawn by:New@engineerinc.io05/12/2022DATE:1-PHASE MICRO-INVERTER UL1741HANWHA 400 WATT MODULES2828ENPHASE IQ8PLUS MICROINVERTERSSYSTEM RATING AND DER POWER OUTPUTINVERTER:ENPHASE IQ8PLUS-72-2-USINVERTER MAXIMUM CONTINUOUS OUTPUT:290VASYSTEM POWER OUTPUT:ENPHASE IQ8PLUS MICROINVERTERS1 PHASE 290VAMAXIMUM OUTPUT CURRENT 1.21AAC PORT BACKFEED CURRENT 0ADC SHORT CIRCUIT CURRENT 15ADC 11.20 KW STCAC 8.12 KW STCDC 11.20 KW STCAC 8.12 KW STC Dakota Electric33.88A33.88A28x 290 =8.12200A East Central Energy Application East Central Energy ApplicationThe lockable visible disconnect must be located within 5 feet from the GeneralService Meter and must be located onthe exterior of the buildingMeter Socket must be ratedand must have lever Bypass200AUtility PV production meter socket withstamped brass aluminium or stainlesssteel tag labeled in accordance with NECand AHJ requirments located within 5' ofmain. Inverter output wired to load sideterminal of meter 1 phase 3-wire120/240V33.88ALoadLine(3) #6 AWG THWN/THWN-23/4" EMT, 2 FEETPV Production meter socket must have leverbypass/bypassProduction meter is required based on the der sizeand program under which the application is submittedNo loads or energy storage systems shall beconnected on the DER side of the production meterLineLoadNOTE: AC DISCONNECT VISIBLE AND LOCKABLE1BRANCHCIRCUIT-A210 (3) #6 AWG THWN/THWN-2 (1) #6 AWG GND 3/4'' EMT, 7 FEET1BRANCHCIRCUIT-B2 J BOX1NEMA3R10.89AMAIN METER120/240V,1P, 3WLine Side Tap(1) #6 AWG GND(NEW)GECAdd 2nd Ground rod andtie it to the existing ground rod.91BRANCHCIRCUIT-C2 8.47A71BRANCHCIRCUIT-C2 2.42AJ BOX2NEMA3RJ BOX3NEMA3R PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Justin Furlong17953 Fulda TrailFarmington, MN 55024CONTRACTORWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comDrawn by:New@engineerinc.io05/12/2022DATE:33.88APV 3.1SYSTEM LABELING DETAILProduction MeterLABEL 1PV ARRAYJ BOXPV SUB-PANELACDISCONNECTMAIN SERVICEPANELMETER233331716218135Note: LABELS SHALL COMPLY WITH NEC 690“Labels shall be weatherproof, durable and permanently mounted”Photovoltaic Power SourceLABEL 2CAUTION: SOLAR CIRCUITLABEL 3WARNINGELECTRIC SHOCK HAZARDTHE DC CONDUCTORS OF THISPHOTOVOLTAIC SYSTEM AREUNDERGROUND AND MAY BE ENERGIZEDLABEL 4WARNINGELECTRIC SHOCK HAZARDIF GROUND FAULT IS INDICATEDNORMALLY GROUNDED CONDUCTORSMAY BE UNDERGROUND AND ENERGIZEDLABEL 5WARNINGELECTRIC SHOCK HAZARDDO NOT TOUCH TERMINALSTERMINALS ON BOTH LINE AND LOADSIDES MAY BE ENERGIZED IN THE OPENPOSITIONLABEL 6WARNINGELECTRIC SHOCK HAZARDDO NOT TOUCH TERMINALSTERMINALS ON BOTH LINE AND LOADSIDES MAY BE ENERGIZED IN THE OPENPOSITIONDC VOLTAGE IS ALWAYS PRESENTWHEN SOLAR MODULESARE EXPOSED TO SUNLIGHTLABEL 7WARNINGLABEL 8TURN OF PHOTOVOLTAICAC DISCONNECT PRIOR TOWORKING INSIDE PANELDO NOT DISCONNECTUNDER LOADLABEL 9MAIN PV SYSTEMDISCONNECTLABEL 10MAIN PV SYSTEMAC DISCONNECTLABEL 11LABEL 12CAUTIONLABEL 13SOLAR ELECTRIC SYSTEMCONNECTEDWARNING-LABEL 14 DUAL POWER SOURCESECOND SOURCE IS PV SYSTEMCAUTIONLABEL 15PHOTOVOLTAIC SYSTEM CIRCUITIS BACKFEDLABEL 16PHOTOVOLTAIC AC DISCONNECTMAXIMUM AC OPERATING CURRENTMAXIMUM AC OPERATING CURRENTPHOTOVOLTAICLABEL 17UTILITY AC DISCONNECTPHOTOVOLTAICLABEL 18DC DISCONNECTNOMINAL OPERATING AC VOLTAGENOMINAL OPERATING AC FREQUANCYMAXIMUM AC POWERMAXIMUM AC CURRENTMAX OCERCURRENT DEVICE RATINGFOR AC MODULE PROTECTIONLABEL 19LABEL 20PV SYSTEM DC DISCONNECTOPERATING CURRENTOPERATING VOLTAGEMAXIMUM SYSTEM VOLTAGESHORT CIRCUIT CURRENTRATED MAX POWER-FONT CURRENTRATED MAX POWER-FONT VOLTAGEMAXIMUM SYSTEM VOLTAGESHORT CIRCUIT CURRENTMAX RATED OUTPUT CURRENT OFTHE CHARGE CONTROLLER IF INSTALLEDLABEL 21***ALL LABELS = RED THERMOPLASTIC/REFLECTIVE , Permanently mounted240VSOLAR DISCONNECT21PerformanceMeter13SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNTURN RAPID SHUTDOWNSWITCH TO THE"OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYSOLAR ELECTRICPV PANELS PLACARDPV 3.2PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Justin Furlong17953 Fulda TrailFarmington, MN 55024CONTRACTORWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comCAUTIONPOWER TO THIS BUILDING IS ALSO SUPPLIEDFROM THE FOLLOWING SOURCES WITHDISCONNECTS LOCATED AS SHOWN:SERVICE 1 OF 2CAUTIONPOWER TO THIS BUILDING IS ALSO SUPPLIEDFROM THE FOLLOWING SOURCES WITHDISCONNECTS LOCATED AS SHOWN:SERVICE 2 OF 2NWESNWESDrawn by:New@engineerinc.io05/12/2022DATE:17953 Fulda TrailFarmington, MN 5502417953 Fulda TrailFarmington, MN 55024SERVICE POINT &UTILITY METERINGPERFORMANCE METERPV SYSTEM DISCONNECTFOR UTILITY OPERATIONENPHASE COMBINER BOXSOLAR PV ARRAYSERVICE POINT &UTILITY METERINGPERFORMANCE METERPV SYSTEM DISCONNECTFOR UTILITY OPERATIONENPHASE COMBINER BOXSOLAR PV ARRAY PROPERTY PLANLEGENDMSPMain Service Panel................PV 4.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Justin Furlong17953 Fulda TrailFarmington, MN 55024CONTRACTOREnphase Combiner BoxECB..........Wolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comMMMain Meter............................Note: 24/ 7 Unescorted keyless access is to beprovided for ALL UTILITY EQUIPMENTDrawn by:New@engineerinc.io05/12/2022DATE: Dakota ElectricPerformance MeterPM...................Utility AC DisconnectUAC.............Fulda TrailDriveway144'-10"152'-5"145'-7"154'-4"17'-6"63'-7"65'-1"64'-2"MSPMMPMACECBPROPERTY LINESCALE:1/16" = 1'-0" 180° 90° 270°0°SWNEDate Certified andSigned: 05/12/2022 ATTACHMENTLAYOUTDESIGN CRITERIAModules:Max Distributed Load: 3 PSFPOINT LOAD CALCULATION PER ARRAYModule Weight (lbs)# Of Modules48.5Total Module Weight (lbs)Rack Weight (lbs)MicroInverters Weight (lbs)Total System Weight (lbs)# Of StandoffsMax Span Between Standoffs (in)Loading Per Standoff (lbs)Total Area (sq.ft.)Loading (PSF)1358271.666.641696.241094815.566162.75RAIL ATTACHMENTMODULES ON ROOFTruss 2 x 4 @ 24" O.C.2828PV 5.1PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Justin Furlong17953 Fulda TrailFarmington, MN 55024CONTRACTORWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com1 Layer of .Plywood & Building FeltSolar Module6"AttachmentMODULES ON ROOFTruss 2 x 4 @ 24" O.C.Comp ShinglePrior to the commencement of work, the contractor shall verify the existing roof and framingconditions. Notify New@engineerinc.io of any Discrepancies prior to starting construction.Prior to the commencement of work, the contractor shall inspect framing for any damagesuch as water damage, cracked framing, etc. and These Plans are stamped for structuralcode compliance of the roof framing supporting the proposed PV installation reference only.These plans are not stamped for water leakage. PV modules, racking, and attachmentcomponents must follow manufacturer guidelines and requirements. Attachments to beinstalled in a staggered orientation to properly distribute loads.1.86"3.05"0.25"Ø2.24"2.58"1"0.17"3.20"1.37"0.38"0.30"1.08"2.78"1.78"1.50"1.99"1.21"R 1.12"Ø0.33"R 0.82"12345SNAPNRACK, SPEEDSEAL FOOT, BASE, SEALING, SILVER/BLACKBOLT, FLANGE, SERRATED, 5/16IN-18 X 2IN, SSSNAPNRACK, RL UNIVERSAL, MOUNT SPRING, SSSNAPNRACK, ULTRA RAIL MOUNT THRU PRC, CLEAR/BLACKSNAPNRACK, ULTRA RAIL MOUNT TAPPED PRC, CLEAR/BLACK12345DESCRIPTIONITEMQTI11111MATERIALS:DESIGN LOAD (LBS):ULTIMATE LOAD (LBS):TORQUE SPECIFICATION:CERTIFICATION:WEIGHT (LBS):DIE CAST A380 ALUMINUM, 6000 SERIES ALUMINUM, STAINESS STEEL802 UP, 1333 DOWN, 357 SIDE2118 UP, 4006 DOWN, 1331 SIDE12 LB-FTUL 2703, FILE E359313; WIND-DRIVEN RAIN TEST FROM SUBJECT UL 25820.45OPTIONS:CLEAR/BLACKPARTS LISTSNAPNRACK, ULTRA RAIL SPEEDSEAL TM FOOTNote: 24/ 7 Unescorted keyless access is to beprovided for ALL UTILITY EQUIPMENTDrawn by:New@engineerinc.io05/12/2022DATE: Dakota Electric23'-9"20'Date Certified andSigned: 05/12/2022 PV 5.2PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Justin Furlong17953 Fulda TrailFarmington, MN 55024ATTACHMENT DETAILCONTRACTORWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comDrawn by:New@engineerinc.io05/12/2022DATE: INVERTERDATA SHEETD 6.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Justin Furlong17953 Fulda TrailFarmington, MN 55024CONTRACTORWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comDrawn by:New@engineerinc.io05/12/2022DATE: ENPHASE RAPIDSHUTDOWN,COMPATIBILITY WITH PVD 7.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Justin Furlong17953 Fulda TrailFarmington, MN 55024CONTRACTORWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comDrawn by:New@engineerinc.io05/12/2022DATE: MODULEDATA SHEETD 8.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Justin Furlong17953 Fulda TrailFarmington, MN 55024CONTRACTORWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comDrawn by:New@engineerinc.io05/12/2022DATE: RACKINGDATA SHEETD 9.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Justin Furlong17953 Fulda TrailFarmington, MN 55024CONTRACTORWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comDrawn by:New@engineerinc.io05/12/2022DATE: ATTACHMENTDATA SHEETD 10.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Justin Furlong17953 Fulda TrailFarmington, MN 55024CONTRACTORWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comDrawn by:New@engineerinc.io05/12/2022DATE: D 11.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Justin Furlong17953 Fulda TrailFarmington, MN 55024CONTRACTORENPHASEAC COMBINER BOXDATASHEETWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comDrawn by:New@engineerinc.io05/12/2022DATE: D 13.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Justin Furlong17953 Fulda TrailFarmington, MN 55024CONTRACTORINVERTERCERTIFICATIONWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comDrawn by:New@engineerinc.io05/12/2022DATE: D 13.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Justin Furlong17953 Fulda TrailFarmington, MN 55024CONTRACTORSURGE PROTECTIONWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comDrawn by:New@engineerinc.io05/12/2022DATE: D 14.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Justin Furlong17953 Fulda TrailFarmington, MN 55024PV INSPECTIONCHECKLISTCONTRACTORWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comWolf RIver ElectricFarmington, MN 5502417953 Fulda TrailDrawn by:New@engineerinc.io05/12/2022DATE: