LA203270 - 18302 Jurel Way Permit Pack
RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: FRONT ELEVATIONSCALE: 1/8"=1'-0"812HARDBOARDSHAKESHARDBOARDB&BLP OR HARDBOARDBRACKET3'-0" 4'-3"1'-0"4" WINDOW/DOORTRIM ON FRONTELEVATION*HARDBOARD ALL 4 SIDES*4 COLORS ON HOUSE*GUTTER & D.S. WHOLE HOUSE812LONG PANELWINDOWS105 HARDBOARD LAP SIDING 28.5%81 HARDBOARD SHAKES 22%46 HARDBOARD B & B 12.5%136 STONE 37%MATERIALS367 TOTAL18X30 STONEBASE W/12X24COMPOSITEPOST W/COLLARSLP WRAPPED BYSIDERBBTRIM ABOVEGARAGE DOORW/BLACK HOUSE #'SREAR ELEVATIONSCALE: 1/8"=1'-0"HARDBOARD4 SIDES8121'-0"ACNO GUTTERSON SHEDROOM5'-0"4" HARDBOARD FEATURE TRIMMATCH HEIGHT TO GARAGEDOOR TRIM HEIGHT812812*HARDBOARD ALL 4 SIDES*4 COLORS ON HOUSE*GUTTER & D.S. WHOLE HOUSEABABHARDBOARDSHAKESHARDBOARDB&B4" HARDBOARD FEATURE TRIMTRIMOPENINGSALL 4 SIDES12X10 PATIORIGHT ELEVATIONSCALE: 1/8"=1'-0"SUMPDISCHARGESPIGOTD.S. INTODRAIN TILE1'-0"IN-VENTVENTILATION4" FEATURE TRIMMATCH HEIGHT TOGARAGE DOOR TRIMHEIGHT8128123' CLEARGASABGASSERVICEBBATTON STRIPFOR SIDINGAKenwood Hills #118302 Jurel WayLot 2 Block 1 Kenwood Hills 3rdLakeville, MN 55044 Job#: 600-140LEFT ELEVATIONSCALE: 1/8"=1'-0"ASPHALT SHINGLES30 YR ARCH.ROOF VENTSIN-VENTVENTILATIOND.S.ELECTRICALSERVICEDRYERVENT1'-0"AC4" FEATURE TRIMMATCH HEIGHT TOGARAGE DOOR TRIMHEIGHT812ABBATTON STRIPFOR SIDINGFinal Blueprint ____/____/_____ ______________ All changes after above date will be done according to F.F.H. Change Order Policy Homeowner Signature FIELDSTONE FAMILY HOMES INC. Lic. # BC631164 Intellectual property of Fieldstone Family Homes, Inc.© 2008. ALL RIGHTS RESERVED. These plan drawings, including but not limited to, all text, designs, renditions, floor plans, along with the selection and arrangement of thereof, are original copyrighted materials owned by Fieldstone Family Homes, Inc. These materials are protected by federal law against unauthorized copying, or reproduction by unauthorized persons and entities. KENWOOD HILLS 3RD LOT 2 BLK 1 KENWOOD HILLS #1 1Scale: 1/8" = 1'-0"Fin Sq Ft: 2632Agent:ELEVATIONS13-21 OCTOBER Plan: MAJECTIC Foundation: 2112 Finished: 2632 Unfinished: 423 Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode06/22/2022dmathewsUA Alternative Used On House Envelope-All concrete foundation walls includingfull height, and lookout must have R-5 insulationon the interior in addition to the R-10 on theexterior regardless of Blower Door Test.-Attic insulation must be increased to R-60 3'-6" DAYLIGHT WALL 20X8 FTGS STEP GARAGEWALL PER SURVEY4X6.6 TREATED 16X8 FTGS 8'-4" FULL BSMT POURED 20X8 FTGS 8'-4" FULL BSMT POURED 20X8 FTGS STEP GARAGE WALL PER SURVEY UNEXCAVATED 4" CONC.SLAB SLOPE AS REQ'D PER CODE CONC. PIER 24X24CONC. PIER 24X24 PORTAL WALL STRAPS 16'-3" M.O. CONC STOOP32'-0"4'-2"36'-2"12'-10"26'-10"39'-8"44'-0"12'-0"8'-0" 20'-0"5'-0"14'-0"58'-0"20'-0" 40'-0"22'-0"58'-2"9'-0"3'-0"17'-5"5'-11"4'-8"26'-7"26'-1"5'-11"13'-6" 2'-1 1/2" 7'-10"18'-4" 20'-6" 2X6 WALL 2X6 WALL 8'-4" FULL BSMT POURED 20X8 FTGS 7'-8" POURED 20X8 FTGS 3'-6" FULL BSMT POURED 20X8 FTGS 8'-4" FULL BSMT POURED 20X8 FTGS 8'-4" FULL BSMT POURED 20X8 FTGS 8'-4" FULL BSMT POURED 20X8 FTGS 8'-4" FULL BSMT POURED 20X8 FTGS JOG HOUSE 2" FOR FOAM INSULATION JOG HOUSE 2" FOR FOAM INSULATION 6'-0"8'-0"8'-0"5' CONC SIDEWALK 5' RECESS STEP 2X6 WALL 13'-6" 3'-6" WALKOUT WALLPOURED 20X8 FTGS 3'-6" DAYLIGHTPOURED20X8 FTGS8'-4" FULL BSMT POURED 20X8 FTGS ANCHOR BOLTLOCATION EVERY 6'STARTING THISCORNER. PLACE ONEANCHOR BOLT 1'FROM EACH SIDE OFTHE 16' SPLICE 4X6 TREATED LAY FLAT 6"4"4"4" CONC. FLOOR 16X8 CONC. FTG FRAMER NOTE: INTERIOR CURB DETAIL FOR 2X6 BEARING WALL MECHANICAL FASTENER TO FOOTING BY FRAMER FRAMER TO CUT OUT CURB FOOTING AT DOOR OPENINGS *ANCHOR BOLTS PLACED ACCORDING TO IRC SECTION 404- R.404.1 (3) TABLE R404.1(1) DOUBLES AT 16' PLATE SPLICES SO BOLT @ 15' & 17' (x x) ANCHOR BOLTS CENTER ON WALL WITH FOAM ANCHOR BOLTS 134" INSIDE FROM WALLS WITH NO FOAM GROUND ROD INSULATE INSIDE OFW.O. TRENCH R10NO FOAM ON CONC.FLOOR LEDGE NO INSULATION ON CONC. LEDGE OF HOUSE COMMON WALL X X 5'-0"X X X X X X D.S. INTO 6" DRAIN TILE NO ANCHOR BOLTS INDOOR OPENING NO ANCHOR BOLTS INWINDOW OPENING3'-6" WALKOUT WALLPOURED 20X8 FTGS 6'-10"14'-0"11'-0"6'-4"5'-6"5'-3"6"X6" CEDAR POST FRAMEDW/ 16" DIA. CONC. FTG MIN. FOR EXTERIORFOOTINGS & 19" CONC. FTG MIN. FOR MIDDLE FOOTING 42" BELOW GRADE. (TYP.)10'-7"16'-0"5'-3"10'-0"2'-11"1'-2 1/2" FD SEALED SB 9'-0"9'-0"10'-0"XX12X10 PATIO Kenwood Hills #118302 Jurel WayLot 2 Block 1 Kenwood Hills 3rdLakeville, MN 55044 Job#: 600-140Final Blueprint ____/____/_____ ______________ All changes after above date will be done according to F.F.H. Change Order Policy Homeowner Signature FIELDSTONE FAMILY HOMES INC. Lic. # BC631164 Intellectual property of Fieldstone Family Homes, Inc.© 2008. ALL RIGHTS RESERVED. These plan drawings, including but not limited to, all text, designs, renditions, floor plans, along with the selection and arrangement of thereof, are original copyrighted materials owned by Fieldstone Family Homes, Inc. These materials are protected by federal law against unauthorized copying, or reproduction by unauthorized persons and entities. KENWOOD HILLS 3RD LOT 2 BLK 1 KENWOOD HILLS #1 2Scale: 1/4" = 1'-0"Fin Sq Ft:Agent: FOUNDATION13-21 OCTOBER Plan: MAJESTIC Foundation: 2112 Finished: 2632 Unfinished: 423 UFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. 92% FURNACE SEALED COMBUSTION FD 50 GAL WH POWER VENT SEALED SB GROUND ROD AIR EXCHANGE 80 SQFT OPEN UNFINISHED MECHANICAL SPIGOT CANT UNEXCAVATED 4" CONC.SLAB SLOPE AS REQ'D PER CODE SPIGOT UNFINISHED STORAGE PORTAL WALL STRAPS CARPET 16'-3" M.O. UP CONC STOOP 4-STRINGERS32'-0"4'-0"36'-0"13'-0"27'-0"40'-0"44'-0"20'-0" 12'-0"8'-0" 20'-0"5'-0"14'-0"58'-0"20'-0" 40'-0"22'-0"58'-0"9'-0"3'-0"26'-7"17'-5"5'-11"4'-8"SD/CO FG60"x36"SHOWERW/ SEAT 26'-1"5'-11"12" SHRK LID TO CODE MFG 18" FLOORTRUSSES @ 16" O.C.@ 25' SPANMFG 18" FLOORTRUSSES @ 16" O.C.MFG 18" FLOORTRUSSES @ 16" O.C.25' SPAN5'-6" 2X6 BEARING WALL WALL W/ BLOCKING 2-9 12" M/L (10') FLUSH TO HANG FROM FLOOR TRUSSES 5040 GL2-2X10 (12') 12 WALL W/ WOOD CAP 2'-1 1/2" 8'-0" 20'-8" 8'-0"12'-8" 12" SHRK LID TO CODEMFG 18" FLOORTRUSSES @ 24" O.C.MFG 18" FLOORTRUSSES @ 24" O.C.17' SPAN9'-4" FLOOR TRUSS LOCATION FOR FLOOR ABOVE AT 8'-6"14'-0"7'-10"5'-6"3'-0"4'-5"SINGLE 26 26 BEDROOM 3 CARPET FAMILY ROOM CARPET 26 BATH VINYL PH48" 18" LINEN 2X6 WALLMFG 18"FLOORTRUSSES @24" O.C.5' RECESS STEP 6'-0"8'-0"8'-0"5' CONC SIDEWALK SD 13'-2"12'-2"24 14'-0"12'-7"11'-2"12'-5"7'-10" SINGLE 3'-10" SD BEDROOM 4 CARPET 3'-3"5036 GL 2-2X10 (12') 2X6 BEARING WALL WALL W/ BLOCKING 12 WALL W/ WOOD CAP 12 WALL W/WOOD CAP 26 3'-0"2X6 BEARING WALL WALL W/ BLOCKING 13'-6" 5'-6"5'-3"2X10 TREATEDJOISTS @ 16"O.C. SPACINGMINIMUM OF FOUR DTT1Z DECKTENSION TIES MUST BE EVENLYDISTRIBUTED ALONG THE DECKWITH ONE DTT1Z WITH IN TWOFEET OF EACH END OF THELEDGER 2-2X10 TRDBEAMS4X6 TREATEDLAY FLAT6"4"4"4" CONC.FLOOR16X8 CONC.FTGFRAMER NOTE:INTERIORCURB DETAIL FOR 2X6BEARING WALLMECHANICALFASTENER TOFOOTING BYFRAMERFRAMER TO CUT OUTCURB FOOTING ATDOOR OPENINGS FRAMER NOTES:-ALL WINDOWS/DOOR TO HAVEDOUBLE JACK STUDS-WINDOWS/DOORS LARGER THAN 8'TO HAVE DOUBLE KING STUDS6"X6" CEDAR POST FRAMEDW/ 16" DIA. CONC. FTG MIN. FOR EXTERIORFOOTINGS & 19" CONC. FTG MIN. FOR MIDDLE FOOTING 42" BELOW GRADE. (TYP.) D.S. INTO DRAIN TILE MFG 18" FLOORTRUSSES @ 16" O.C.@ 26' SPAN6'-0"FRAME WALL FLUSH SUMP DISCHARGE 6'-6"20'-6" 6'-2" FRAMEFULL WALLNO LEDGE FRAME FULL WALL NO LEDGE 5'-10"FRAMEFULL WALLNO LEDGE GASMETERELECTRICALPANEL5'-0"AC ONBRACKETSTO HOUSE- SHOWERWALL FANTRUSS SPACINGCHANGE10'-9"16'-0"5'-3"10'-0"2-2X8 FLUSH 8'-6" 2-2X8 FLUSH 6/0 SGD2-9 12" M/L(14')5040 GL2-2X10 (12') UNDER COUNTER WINE FRIG 8'-6"1'-0"2-2X10(12') 28 BAR AREA VINYL FL O O R B R E A K VINYL VINYL 8'-0"12X10 PATIO Kenwood Hills #118302 Jurel WayLot 2 Block 1 Kenwood Hills 3rdLakeville, MN 55044 Job#: 600-140Final Blueprint ____/____/_____ ______________ All changes after above date will be done according to F.F.H. Change Order Policy Homeowner Signature FIELDSTONE FAMILY HOMES INC. Lic. # BC631164 Intellectual property of Fieldstone Family Homes, Inc.© 2008. ALL RIGHTS RESERVED. These plan drawings, including but not limited to, all text, designs, renditions, floor plans, along with the selection and arrangement of thereof, are original copyrighted materials owned by Fieldstone Family Homes, Inc. These materials are protected by federal law against unauthorized copying, or reproduction by unauthorized persons and entities. KENWOOD HILLS 3RD LOT 2 BLK 1 KENWOOD HILLS #1 3Scale: 1/4" = 1'-0"Fin Sq Ft: 1101Agent:LOWER LEVEL13-21 OCTOBER MAJESTIC Foundation: 2112 Finished: 2632 Unfinished: 423 FANUA Alternative Used On House Envelope-All concrete foundation walls includingfull height, and lookout must have R-5 insulationon the interior in addition to the R-10 on theexterior regardless of Blower Door Test.-Attic insulation must be increased to R-60 GREAT ROOMLAMT DINETTELAMT KITCHEN LAMT FOYER LAMT GARAGE 4" CONC.SLAB SLOPE AS REQ'D PER CODE OWNERS BEDROOM CARPET WIC CARPET FAN OWNERS BATH VINYL 9' CEILINGS SET WINDOWS @ 8'-0" CARPET 16X7 GARAGE DOOR LONG RANCH PANEL WINDOWS W/ GRIDS 3-1178" M/L (18') LAUNDRY ROOM VINYL TR DN MFG ROOF TRUSSES @ 24" O.C. HDDURASTRANDSUB FLOOR* FALL PROTECTIONWINDOWS ABOVEEGRESS ONLY ATTIC ACCESS 22X32 DW SD SD 72" BEDROOM 2 CARPETSINGLESTACKDOUBLE PH CONC STOOP FAN BATH VINYL TB PH 60" X 34" FG BASE W/ TILE WALLS FULL DEPTH RAISED 28 3-P 20 MIN FIRE RATED STEEL 2-2X10 (8') 30 W/ GLASS TRAN ABOVE 2-2X10 (8') TWILIGHT IISEE THROUGHNO HEARTHFLUSH POTKENWOOD SURROUND STONE FACE BYFIREPLACE INSTALLER2'-2"2'-2" 4-STRINGERS 3052 SH 2-2X10 (8') 3044 PIC3020AWNINGBELOW2-2X10 (8') 4044 SH 2-2X10 (10') SD/CO 28 POC 26 24" BASE MUD ROOM LAMT SINGLE30"6034TUB/SHOWERCOMBO60" FRAMED WOOD CAP BENCH FRAME BENCH OPEN BELOW - NTS 17" H 18" D 60" W WOOD CAP RANGE W/ HOOD VENT ABOVE32'-0"4'-0"36'-0"13'-0"27'-0"40'-0"44'-0"20'-0" 12'-0" 20'-0"5'-0"59'-0"20'-0" 40'-0"22'-0"59'-0"17'-0"3'-0"11'-0"7'-0"13'-8"6'-0"9'-6"9'-6"3'-0"14'-4"5'-0"6'-6"12'-4"9'-0" 3'-6"2'-6"3'-3"3'-10"12'-6"7'-11"19'-6"4'-0"2'-10"5'-0"13'-6"3'-2"9'-2"4'-4" 24 4'-4"3'-0" 1'-0" BOOK SHELF 7' CABINET 6'-0"4'-6"8'-0"6'-6" 5'-0"6'-6"1'-0"8"5'-10"2'-6"1'-10"*3052 SH1-2X10 (8')*3052 SH1-2X10 (8')7'-3"7'-11"7'-0" MFG ROOF TRUSSES@ 24" O.C. SD/CO 36" LINEN 18" FLUSH SNACK BAR SINGLE 26 DBL 2/0 12 GLASS 28 28 28 3030 AWNING 2-2X10 (8')2'-5"2'-1"2020 TRANSOM 2-2X10 (8') 2020 TRANSOM 2-2X10 (8')8'-0"3'-0" 2-2X8 (20') FLUSH 5' RECESS STEP 2X6 WALL 6'-4" 2'-2" 2'-3" 5' CONC SIDEWALK 30" DRAWER STACK W/ WOOD TOP 1'-8"BASE CABINET W/ LAMT TOP 12 WALL W/ WOOD CAP EB 1'-9"2838 SH 2-2X10 (8') FULL ROCK GARAGE PORTAL WALL FRAMING SCUTTLE ACCESS 22X32 6" DEEP LEDGE 44" OFF FLOOR STAT 3"RECESS FRIG 27" END PNL EA SIDE OF FRIG. EB 84" ISLAND GUTTER AND D.S.5'-0"6'-0"2'-4"4'-0"3'-2"3'-0"MFG ROOF TRUSSES@ 24" O.C.MFG ROOF TRUSSES @ 24" O.C. USE HOUSE WALL AS BEARING FOR ROOF TRUSSES - EXTEND HEELS 8'-0" 1'-1 1/2" 11'-9" 16X10 TREXDECK W/BLACKALUMINUMRAILINGCENTER ON FP FRAMER NOTES:-ALL WINDOWS/DOOR TO HAVEDOUBLE JACK STUDS-WINDOWS/DOORS LARGER THAN 8'TO HAVE DOUBLE KING STUDS WDD.S.D.S. INTO DRAIN TILE 26 AIR EXCHANGE 1'-0"CANTCANTELECTRICALPANEL18X30 STONE BASE W/12X24 COMPOSITE POST W/ COLLARS LP WRAPPED BY SIDER 7'-2" 4020TRANSOM2-2X10 (10')GASMETER2X6 WALLTREX STEPSDOUBLEWOOD 20STACK 10'-9"16'-0"30 ATRIUMDOOR2-2X10 (8')3'-8"1'-0"SHED ROOFABOVE MICROWAVESHELF16'-6"3'-6"8'-0"11'-10" BOX CEILING FLAT PAINTED CEILING IN BOX VAULT W/CROWN MOULDING & LIGHTS 3044 PIC3020AWNINGBELOW2-2X10 (8')10" FLUSHSNACK BARPOST LEGS BY CABT. CO. FLOATING LAMT LAMT LAMT PAINTED WALL 1X4 BASE CHAIR RAIL FOYER/GARAGE WALL FOYER/BEDROOM CLOSET WALL PAINTED WALL 1X4 BASE CHAIR RAIL 2'-6" 3'-0" SEE LL FOR HEAD ROOM STONE FACE FPFROM DECK TO SOFFIT CHAIR RAIL-SEE DETAILCHAIR RAIL-SEE DETAILFOYER CHAIR RAIL 18" BASE CABINET OPEN (NO DOORS) W/ LAMT TOP PANTRY ORGANIZER SHELF CUBBIES ABOVE PANTRY 18" BASE CABINETOPEN (NO DOORS) W/LAMT TOPPANTRY ORGANIZERSHELF CUBBIES ABOVE10'-0"VALVEGLASSPANEL BOX VAULTABOVE ISLANDCROWN W/LIGHT INBOX VAULT 5"3 1/2"3 1/2"Kenwood Hills #118302 Jurel WayLot 2 Block 1 Kenwood Hills 3rdLakeville, MN 55044 Job#: 600-140Final Blueprint ____/____/_____ ______________ All changes after above date will be done according to F.F.H. Change Order Policy Homeowner Signature FIELDSTONE FAMILY HOMES INC. Lic. # BC631164 Intellectual property of Fieldstone Family Homes, Inc.© 2008. ALL RIGHTS RESERVED. These plan drawings, including but not limited to, all text, designs, renditions, floor plans, along with the selection and arrangement of thereof, are original copyrighted materials owned by Fieldstone Family Homes, Inc. These materials are protected by federal law against unauthorized copying, or reproduction by unauthorized persons and entities. KENWOOD HILLS 3RD LOT 2 BLK 1 KENWOOD HILLS #1 4Scale: 1/4" = 1'-0"Fin Sq Ft: 1531Agent:MAIN LEVEL13-21 OCTOBER Plan: MAJESTIC Foundation: 2112 Finished: 2632 Unfinished: 423 -Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).3PFHPFH5UA Alternative Used On House Envelope-All concrete foundation walls includingfull height, and lookout must have R-5 insulationon the interior in addition to the R-10 on theexterior regardless of Blower Door Test.-Attic insulation must be increased to R-60 **NOTE: WATERPROOFING IS THE WATCHDOG METHOD PERFORMED BYINSTALLED BUILDING SOLUTIONS. NON DRAINING BOARD INSULATIONW/ 6 MIL POLY SLIP SHEETHING OVER TOP. ANY QUESTIONSREGARDING THIS TYPE OF WATERPROOFING SYSTEM SHOULD BEDIRECTED TO BRET JUENKE #651-463-9333ALL STRUCTURAL LUMBER2X8 AND ABOVE WILL BE SPF NO. 2 AND BETTERALL 2X4 AND 2X6 STUDS WILL BE WESTERNWHITES NO. 2 OR BETTER**NOTE: APPROVED VAPOR RETARDER WITH JOINTSLAPPED NOT LESS THAN 6" BELOW CONCRETE SLAB75% OF THE BULBS IN PERMANENTLY INSTALLEDLIGHT FIXTURES MUST BE HIGH EFFICACY. THISREQUIREMENT APPLIES TO INDOOR ANDOUTDOOR FIXTURES, INCLUDING ACCESSORYSTRUCTURES AND GARAGES. HIGH EFFICACYBULBS ARE: 60 LUMENS/W FOR LAMPS OVER40W; 50 LUMENS/W FOR LAMPS OVER 15W TO40W; 40 LUMENS/W FOR LAMPS 15W OR LESSR 404.1 LIGHTING EQUIPMENTA MINIMUM OF 75 PERCENT OF THE LAMPS INPERMANENTLY INSTALLED LIGHTING FIXTURESSHALL BE HIGH-EFFICACY LAMPS OR A MINIMUMOF 75 PERCENT OF THE PERMANENTLY INSTALLEDLIGHTING FIXTURES SHALL CONTAIN ONLY HIGHEFFICACY LAMPS.WINDOWS ARE MAXIMUM OF .30U-VALUE WITH MAXIMUM SHGC .29WINDOW FALL PROTECTION PERR312.2.1 AND R312.2.2PATIO DOORS .30U AND .26 SHGCALL STEEL DOORS .19UPERELEVATION2X6 @ 16" O.C.AIR INFILTRATION BARRIERALL EXTERIOR WALLSVINYL SIDINGEXTERIOR WALL SHEATHING12" GYP BD.4" MIL VAPOR BARRIER WARMSIDE OF ALL WALLS AND CEILINGSDRAIN TILE REQUIREDSLEEVED W/ ROCKPASSIVE RADONSYSTEM AS REQUIREDW/ WASHED ROCKR-20FIBERGLASSBATT INSULATIONR-20 SPRAYFOAMCLOSED CELLVENTED ALUMINUM SOFFIT2X6 & ALUMINUM FACIAMETAL DRIP EDGERIGID WIND WASHRT7 TRUSS TIE DOWN BY USPCONNECTIONS OR EQUALMFG. TRUSSES @ 24" O.C.712" ENERGY HEEL6'-0" ICE AND WATER SHEILDOSB ROOF SHEATHINGR-50 INSULATION1" AIR SPACE**NOTE: WALL CONSTRUCTED CAPABLE OF ACCOMADATING ALLLOADS IMPOSED MEETING THE REQUIREMENTS OF IRC 2015NOTE: VENT 1300TH ROOF 12 IN SOFFIT12 IN ROOF NEAR RIDGEFLASH ABOVE ALL EXTERIOR OPENINGSSHINGLES PER ELEVATION/SPECS.15# FELT12" ROOF SHEATHINGSEE ELEVATIONRADON VENT PIPE TERMINATED ATLEAST 12" ABOVE SURFACE OF ROOFMINIMUM 3" ABS OR PVC OREQUIVALENT GAS TIGHT PIPE4" PIPE MAY BE MORE EFFECTIVE, BUTNOT REQUIREDSPACE PROVIDED FOR INSTALLATIONOF A FAN - MINIMUM 24" DIAMETER CENTEREDON THE AXIS OF THE VENT STACK - MINIMUM VERTICAL DISTANCE OF 3FEETR-10 INSULATIONHOUSE WRAPINSTALLED BYFRAMERFRAMING TOOVERHANG 112"ONTO INSULATIONFLOOR TRUSSES TO BEENGINEERED TOTRANSFER LOAD OFOVER HANG TOBEARING WALLBLOCKING REQUIRED TOCARRY AND TRANSFERLOADS TO BEARINGWALLSFLOOR TRUSSES TO BEENGINEERED TOTRANSFER LOAD OFOVER HANG TOBEARING WALLBLOCKING REQUIRED TOCARRY AND TRANSFERLOADS TO BEARINGWALLSNON-BEARING WALLBLOCKING PER BAMNEED ROOM FOR A35BOLT LOCATION MIN 212"FROM EXTERIOR EDGEOF CONCRETE WALLR-5 INSULATIONNON BEARING EXTERIORFOUNDATION WALLSTYPICAL ANCHORING1/2" X 12" ANCHOR BOLT ORSTRAP 6'-0" O.C. @ WALLRUNS 12" O.C. @ WALL ENDSSCUFF COAT INSUL.GRADER-10 INSULATION3'-6" POURED WALKOUTFOUNDATION WALL 20" X 8" FOOTINGGARAGE AND WALKOUTFOOTINGS @ 42" MIN.BELOW GRADE4" CONC. SLAB REF. AS REQ. ON6 MIL SEALED MOISTURE BARRIERON 6" COMPACTED GRANULAR FILLR-5 INSULATION34" T&G GLUED OSBSINGLE LAYER FLOOR SYSTEMRADON VENT PIPE IN ATTIC - INSULATE WITHMIN. R-4 PIPE WRAP2X8 TRD BOTTOM PLATECANTILEVERED1.5" OVER INSULATION2X8 BASEMENTEXTERIOR WALLFRAMING (WALKOUTWALL) 2X6 EXTERIOR ALLOTHERS10' MAX HEIGHT 'PONY WALLHEIGHT12' MAX TOTAL WALL HEIGHT EXTENT OF HEADER WITH DOUBLE PORTAL FRAMES (TWO BRACED WALL PANELS)EXTENT OF HEADER WITH SINGLE PORTAL FRAME (ONE BRACEDWALL PANEL)2'-18' FINISHED WIDTH OF OPENINGFOR SINGLE OR DOUBLE PORTALMIN. 3"X11-1/4" NET HEADER -STEEL HEADER PROHIBITEDFASTEN SHEATHING TO HEADER WITH 8DCOMMON OR GALVANIZED BOX NAILS IN 3" GRIDPATTERN AS SHOWNHEADER TO JACK-STUD STRAP PER TABLER 602.10.8.4 ON BOTH SIDES OF OPENINGOPPOSITE SIDE OF SHEATHINGMIN. DOUBLE 2X4 FRAMING COVERED WITH MIN.716" THICK WOOD STRUCTURAL PANELSHEATHING WITH 8D COMMON OR GALVANIZEDBOX NAILS AT 3" O.C. IN ALL FRAMING (STUDS,BLOCKING, AND SILLS) TYP.MIN. LENGTH OF PANEL PER TABLE R602.10.5MIN. (2) 12" DIAMETER ANCHOR BOLTS INSTALLED PERR403.1.6 WITH 2"X2'X316" PLATE WASHERTENSION STRAP PERTABLE 602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)BRACED WALL LINECONTINUOUSLY SHEATHEDWITH WOOD STRUCTURALPANELSIF NEEDED PANELSPLICE EDGES SHALL OCCURAND BE ATTACHED TOCOMMON BLOCKINGWITHIN 24" OF WALLMID-HEIGHT. ONE ROW OF3" O.C. NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTAL FRAMECONSTRUCTIONMIN. DOUBLE 2X4 POST(KING AND JACK STUD)NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).ANCHOR BOLTS PERSECTION R403.1.6FASTEN TOP PLATE TOHEADER WITH TWOROWS OF 16D SINKERNAILS AT 3" O.C. TYP.MIN. 7/16 " WOODSTRUCTURAL PANELSHEATHING12" OSB18" MFG TRUSSES @ 24" O.C.34" T & G GLUED OSB SINGLELAYER FLOOR SYSTEMR-30 SPRAYFOAMCANTILEVERKenwood Hills #118302 Jurel WayLot 2 Block 1 Kenwood Hills 3rdLakeville, MN 55044 Job#: 600-140Final Blueprint ____/____/_____ ______________ All changes after above date will be done according to F.F.H. Change Order Policy Homeowner Signature FIELDSTONE FAMILY HOMES INC. Lic. # BC631164 Intellectual property of Fieldstone Family Homes, Inc.© 2008. ALL RIGHTS RESERVED. These plan drawings, including but not limited to, all text, designs, renditions, floor plans, along with the selection and arrangement of thereof, are original copyrighted materials owned by Fieldstone Family Homes, Inc. These materials are protected by federal law against unauthorized copying, or reproduction by unauthorized persons and entities. KENWOOD HILLS 3RD LOT 2 BLK 1 KENWOOD HILLS #1 5Scale: 1/4" = 1'-0"Fin Sq Ft:Agent:SECTIONS13-21 OCTOBER Plan: MAJESTIC Foundation: 2112 Finished: 2632 Unfinished: 423 R-60 Required for UAAlternativeUA Alternative Used On House Envelope-All concrete foundation walls includingfull height, and lookout must have R-5 insulationon the interior in addition to the R-10 on theexterior regardless of Blower Door Test.-Attic insulation must be increased to R-60 INSTALL VENT PIPE (AF103.6.1) INTOSUBFLOOR GAS PERMEABLE LAYER(AF103.2) OR DRAIN TILE LOOPBEFORE SLAB IS CASTSEALEDSUMPBASKETDRAIN TILEMIN. 6-MIL, OR 3-MIL CROSSLAMINATED POLYETHYLENE SHALL BELAPPED 12" AND PLACED BELOW THESLAB AND ON TOP OF THE GASPERMEABLE LAYER (AF103.3)-FIT POLYETHYLENE LAYER CLOSELY TOPENETRATIONS (AF103.3)- SEAL/CLOVER PUNCTURES OR TEARSWITH ADDITIONAL POLYETHYLENE(AF103.3)SEAL ALL JOINTS, CRACKS, OR OTHEROPENINGS WITH POLYURETHANE CAULKOR ELASTOMERIC SEALANT ACCORDINGTO MANUFACTURER'SRECOMMENDATIONS IN AF103.4.1THROUGH AF103.4.5INSTALL PIPE AS STRAIGHT ASPOSSIBLE TO HELP CONDUCTIVE FLOWELBOWS AREA ALLOWED BUT SHOULDBE AVOIDED IF POSSIBLEINSTALL LABEL READING *RADONREDUCTION SYSTEM* ON THE VENTPIPE AT EACH FLOOR AND INACCESSIBLE ATTICS. (AF103.4.5)RADON VENT PIPE TERMINATED ATLEAST 12" ABOVE SURFACE OF ROOFMINIMUM 3" PVC GAS TIGHT PIPE.SPACE PROVIDED FOR FUTUREINSTALLATION OF A FAN-MIN 24" DIAMETER CENTERED ON THEAXIS OF THE VENT STACK- MIN VERTICAL DISTANCE OF 3 FEETINSTALL LIVE OUTLET IN ATTIC NEARWHERE FUTURE FAN MAY BE INSTALLED8'-1 1/2" 9'-8 1/4" 9'-1 1/8" 1'-6" 9 1/2" 8'-3 5/8" 8'-4" 4'-5 3/8" 7'-11 3/8" 9 1/4"Kenwood Hills #118302 Jurel WayLot 2 Block 1 Kenwood Hills 3rdLakeville, MN 55044 Job#: 600-14030" ABOVE STOOPSTOOP2X430X18 BASE FOR12X24COMPOSITECOLUMN12" GTOSB4 SIDES2X6 GT2X62X42X42X6 GT73 4"10"6'-10" MIN AT ROUGH IN FRAMING 36" MIN 3/4" PLYWOOD NAILED BETWEENSTRINGER & FLR SYSTEM-CUT FLUSH WITH BOTTOM OFSTRINGEROSB TREADS4-RIM STRINGERSGRASPABLE HANDRAIL TYPE IOVAL 2 14" WIDE X 1 14" HIGHBRACKETS @ 4' O.C.38" MAX1X82X4TWILIGHT II FIREPLACE 47 58"41 14"EXTERIOR FRAMING HEIGHTINTERIOR FRAMING HEIGHT23"44"8'-1 1/2" 9'-8 1/4"8'-0"8'-6"9'-4"6'-10"2X10 LEDGER STRIP5 1/4" TREX DECKING2X10 HOT DIPPEDGALV. JST HANGERS2X10 TRTD JOISTSGALV. FLASHINGHOT DIPPEDDBL 2X10 TRTD RIMSTREX KICKDECK LEDGER DETAILSLEDGER FLASHING DETAILPATIO DOOR THRESHOLDROLL FLASHING1X8 TREX FLASHINGDECK LEDGERHOUSE WRAP HOUSE WRAPCAULKINGMFG FLOOR TRUSSES12" DIAMETER LAG SCREWWITH 1532" MAXIMUMSHEATHING 15" O.C.12" DIAMETER LAG SCREW WITH 1532"MAXIMUM SHEATHING 15" O.C.FLOORTRUSSES6X6 CEDAR POST2X10 TREATED BEAMON EACH SIDE OF NOTCHCARRIAGE BOLT (MIN. 2)NOTCH POST EACH SIDE FORTREATED 2X10Final Blueprint ____/____/_____ ______________ All changes after above date will be done according to F.F.H. Change Order Policy Homeowner Signature FIELDSTONE FAMILY HOMES INC. Lic. # BC631164 Intellectual property of Fieldstone Family Homes, Inc.© 2008. ALL RIGHTS RESERVED. These plan drawings, including but not limited to, all text, designs, renditions, floor plans, along with the selection and arrangement of thereof, are original copyrighted materials owned by Fieldstone Family Homes, Inc. These materials are protected by federal law against unauthorized copying, or reproduction by unauthorized persons and entities. KENWOOD HILLS 3RD LOT 2 BLK 1 KENWOOD HILLS #1 6Scale: 1/4" = 1'-0"Fin Sq Ft:Agent:SECTIONS/DETAILS13-21 OCTOBER Plan: MAJESTIC Foundation: 2112 Finished: 2632 Unfinished: 423 Kenwood Hills #118302 Jurel WayLot 2 Block 1 Kenwood Hills 3rdLakeville, MN 55044 Job#: 600-140PERELEVATIONEXTERIOR WALL SHEATHING12" TYPE X GYPBD. INTERIOR2X4 BLOCKING ALUMINUM SOFFIT2X6 & ALUMINUM FACIA12" FIRE RETARDANTTREATED PLYWOOD @ROOF DECKIN-VENT ROOF VENTILATIONAPPROX 3' FROM EXTERIOR WALLSEE ELEVATION58" TYPE X EXT. GYP BDNO ROOF PENETRATIONS IN THEAREA THAT IS 5' FROM THEPROPERTY LINETO PROPERTY LINEPERELEVATIONEXTERIOR WALL SHEATHING12" TYPE X GYPBD. INTERIOR2X4 BLOCKING ALUMINUM SOFFIT2X6 & ALUMINUM FACIA12" FIRE RETARDANTTREATED PLYWOOD @ROOF DECKIN-VENT ROOF VENTILATIONAPPROX 3' FROM EXTERIOR WALLSEE ELEVATION58" TYPE X EXT. GYP BDNO ROOF PENETRATIONS IN THEAREA THAT IS 5' FROM THEPROPERTY LINETO PROPERTY LINE2X6 HOUSE (1 HR) FIREWALL2X4 GARAGE (1 HR) FIREWALLPOURED FOUNDATION WALLPER PLANTYPICAL ANCHORING12" X 12" ANCHOR BOLT ORSTRAP 6'-0" O.C. @ WALLRUNS 12" O.C. @ WALL ENDSEXTERIOR WALL SHEATHINGGYP. SHEATHINGAIR INFILTRATION BARRIERALL EXT. WALLSGARAGECOMMON WALL2X8 TRD BOTTOM PLATE2X6 @ 16" O.C.3'-6" POUREDFOUNDATION WALLTYPICAL ANCHORING12" X 12" ANCHOR BOLT ORSTRAP 6'-0" O.C. @ WALLRUNS 12" O.C. @ WALL ENDSGRADEEXTERIOR WALL SHEATHINGVINYL SIDINGAIR INFILTRATION BARRIERALL EXT. WALLSVENTED ALUMINUM SOFFIT2X6 & ALUMINUM FACIAMETAL DRIP EDGERIGID WIND WASHRT7 TRUSS TIE DOWN BY USPCONNECTIONS OR EQUALMFG. TRUSSES @ 24" O.C.HEEL AS NEEDED6'-0" ICE AND WATER SHEILDOSB ROOF SHEATHING1" AIR SPACE**NOTE: WALL CONSTRUCTED CAPABLE OF ACCOMADATING ALLLOADS IMPOSED MEETING THE REQUIREMENTS OF IRC 2015NOTE: VENT 1300TH ROOF 12 IN SOFFIT12 IN ROOF NEAR RIDGEFLASH ABOVE ALL EXTERIOR OPENINGSSHINGLES PER ELEVATION/SPECS.15# FELT12" ROOF SHEATHINGSEE ELEVATIONPERELEVATIONGARAGE WALL2X6 TRD BOTTOM PLATE2X6 @ 12" O.C.Final Blueprint ____/____/_____ ______________ All changes after above date will be done according to F.F.H. Change Order Policy Homeowner Signature FIELDSTONE FAMILY HOMES INC. Lic. # BC631164 Intellectual property of Fieldstone Family Homes, Inc.© 2008. ALL RIGHTS RESERVED. These plan drawings, including but not limited to, all text, designs, renditions, floor plans, along with the selection and arrangement of thereof, are original copyrighted materials owned by Fieldstone Family Homes, Inc. These materials are protected by federal law against unauthorized copying, or reproduction by unauthorized persons and entities. KENWOOD HILLS 3RD LOT 3 BLK 1 KENWOOD HILLS #1 7Scale: 1/4" = 1'-0"Fin Sq Ft:Agent: DETAILS13-21 OCTOBER Plan: MAJESTIC Foundation: 2112 Finished: 2632 Unfinished: 423 BWL A1BWL 1-1BWL B1BWL 2-140'-0"44'-0"2'-10"4'-0"2'-1 1/2"2'-1 1/2"2'-0"END CONDT. 5DTT1Z3'-1"17'-0"15'-11"4'-0"19'-4"5'-0"4'-0"3'-5"4'-0"11'-8"4'-0"7'-3"4'-0"15'-8"4'-0"2'-10"6'-0"4'-0"PORTAL WALLFRAMINGKenwood Hills #118302 Jurel WayLot 2 Block 1 Kenwood Hills 3rdLakeville, MN 55044 Job#: 600-14040'-0"4'-0"9'-0"5'-4"2'-10"4'-0"11'-10"3'-0" 4'-0"4'-0"10'-2" = BRACEWALLPANELCONTINUOUS RIM OR BAND JOIST3-16D @ 16" O.C. ALONGBRACED WALL PANELBRACED WALL PANEL8D @ 6" O.C. ALONGBRACED WALL PANELCONTINUOUS RIM OR BAND JOISTPERPENDICULARFRAMINGCONTINUOUS RIM OR BAND JOIST3-16D @ 16" O.C. ALONGBRACED WALL PANELBRACED WALL PANEL8D @ 6" O.C. ALONGBRACED WALL PANELCONTINUOUS RIM OR BAND JOISTPARALLELFRAMING4'-0"NOT TO SCALE38" MINPLYWOOD OROSB6" O.C. EDGENAILING12" O.C.FIELD NAILINGBRACE WALL PANELS: CS-WSPNOT TO SCALEFinal Blueprint ____/____/_____ ______________ All changes after above date will be done according to F.F.H. Change Order Policy Homeowner Signature FIELDSTONE FAMILY HOMES INC. Lic. # BC631164 Intellectual property of Fieldstone Family Homes, Inc.© 2008. ALL RIGHTS RESERVED. These plan drawings, including but not limited to, all text, designs, renditions, floor plans, along with the selection and arrangement of thereof, are original copyrighted materials owned by Fieldstone Family Homes, Inc. These materials are protected by federal law against unauthorized copying, or reproduction by unauthorized persons and entities. KENWOOD HILLS 3RD LOT 2 BLK 1 KENWOOD HILLS #1 8Scale: 3/16" = 1'-0"Fin Sq Ft:Agent: BRACE WALL13-21 OCTOBER Plan: MAJESTIC Foundation: 2112 Finished: 2632 Unfinished: 423 Mid State Plumbing & Heating HVAC Load Calculations for Majestic Lot 2 Block 1 Lakeville, MN Prepared By: Wednesday, February 2, 2022 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth)Mid State Plumbing & Heating Plymouth, MN 55441 Page 2 Project Report General Project Information Project Title:Mid State Plumbing & Heating Project Date:Thursday, January 27, 2022 Client Name:Majestic Client Address:Lot 2 Block 1 Client City:Lakeville, MN Design Data Reference City:Minneapolis/St. Paul AP, Minnesota Building Orientation:Front door faces Southwest Daily Temperature Range:Medium Latitude:44 Degrees Elevation:834 ft. Altitude Factor:0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter:-15 -15 n/a n/a 72 n/a Summer:88 71 44%50%75 24 Check Figures Total Building Supply CFM:686 CFM Per Square ft.:0.225 Square ft. of Room Area:3,055 Square ft. Per Ton:1,879 Volume (ft³):20,723 Building Loads Total Heating Required Including Ventilation Air:44,313 Btuh 44.313 MBH Total Sensible Gain:15,457 Btuh 79 % Total Latent Gain:4,053 Btuh 21 % Total Cooling Required Including Ventilation Air:19,510 Btuh 1.63 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\Mid State Pl ... od Hills.rh9 Wednesday, February 2, 2022, 1:42 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth)Mid State Plumbing & Heating Plymouth, MN 55441 Page 3 Miscellaneous Report System 1 House Input Data Outdoor Dry Bulb Outdoor Wet Bulb Outdoor Rel.Hum Indoor Rel.Hum Indoor Dry Bulb Grains Difference Winter:-15 -15 100%n/a 72 n/a Summer:88 71 44%50%75 23.51 Duct Sizing Inputs Main Trunk Runouts Calculate:Yes Yes Use Schedule:Yes Yes Roughness Factor:0.00300 0.01000 Pressure Drop:0.1000 in.wg./100 ft.0.1000 in.wg./100 ft. Minimum Velocity:0 ft./min 0 ft./min Maximum Velocity:900 ft./min 750 ft./min Minimum Height:0 in.0 in. Maximum Height:0 in.0 in. Outside Air Data Winter Summer Infiltration Specified:0.280 AC/hr 0.150 AC/hr 97 CFM 52 CFM Infiltration Actual:0.280 AC/hr 0.150 AC/hr Above Grade Volume:Cu.ft.Cu.ft.X 20,723 X 20,723 5,802 Cu.ft./hr 3,108 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration:97 CFM 52 CFM Total Building Ventilation:145 CFM 145 CFM ---System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 13.87 = (1.10 X 0.970 X 13.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 15.51 = (0.68 X 0.970 X 23.51 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 92.85 = (1.10 X 0.970 X 87.00 Winter Temp. Difference) Winter Infiltration Specified:0.280 AC/hr (97 CFM), Construction: Average Summer Infiltration Specified:0.150 AC/hr (52 CFM), Construction: Average C:\ ...\Mid State Pl ... od Hills.rh9 Wednesday, February 2, 2022, 1:42 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth)Mid State Plumbing & Heating Plymouth, MN 55441 Page 4 Load Preview Report Scope Net Ton ft.² /Ton Area Sen Gain Lat Gain Net Gain Sen Loss Sys Htg CFM Sys Clg CFM Sys Act CFM Duct Size Building 1.63 1,879 3,055 15,457 4,053 19,510 44,313 521 686 686 System 1 1.63 1,879 3,055 15,457 4,053 19,510 44,313 521 686 686 10x14 Ventilation 805 2,249 3,054 5,385 Zone 1 3,055 14,652 1,804 16,456 38,928 521 686 686 10x14 1-Lower Level 1,524 4,614 670 5,284 16,296 218 216 216 2--7 2-Main Level 1,531 10,038 1,134 11,172 22,632 303 470 470 5--6 C:\ ...\Mid State Pl ... od Hills.rh9 Wednesday, February 2, 2022, 1:42 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth)Mid State Plumbing & Heating Plymouth, MN 55441 Page 5 Duct Size Preview Room or Duct Name Source Minimum Velocity Maximum Velocity Rough. Factor Design L/100 SP Loss Duct Velocity Duct Length Htg Flow Clg Flow Act. Flow Duct Size System 1 Supply Runouts Zone 1 1-Lower Level Built-In 0 750 0.01 0.1 404.4 218 216 216 2--7 2-Main Level Built-In 0 750 0.01 0.1 479 303 470 470 5--6 Other Ducts in System 1 Supply Main Trunk Built-In 0 900 0.003 0.1 706 521 686 686 10x14 SummarySummarySummarySummarySummarySummarySummarySummary System 1 Heating Flow:521 Cooling Flow:686 C:\ ...\Mid State Pl ... od Hills.rh9 Wednesday, February 2, 2022, 1:42 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth)Mid State Plumbing & Heating Plymouth, MN 55441 Page 6 Total Building Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain Marvin: Glazing-Custom Window, U-value 0.32, SHGC 0.34 230.2 6,409 0 6,091 6,091 Fireplace: Glazing-Twighlight 2, U-value 1.25, SHGC 0.8 12 1,305 0 776 776 11P: Door-Metal - Polyurethane Core, U-value 0.29 48 1,212 0 334 334 15B0-10sf-8: Wall-Basement, , R-10 board insulation to floor, no interior finish, 8' floor depth, U-value 0.05 720 3,360 0 62 62 15B0-10sf-4: Wall-Basement, , R-10 board insulation to floor, no interior finish, 4' floor depth, U-value 0.054 106 498 0 0 0 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs, U-value 0.065 1907.8 10,788 0 1,650 1,650 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation, U-value 0.02 1531.2 2,664 0 1,470 1,470 21B-20: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, R-3 or higher insulation installed below floor, any floor cover, shortest side of floor slab is 20' wide, U-value 0.019 1524 2,519 0 0 0 22D-10pm: Floor-Slab on grade, Vertical board insulation covers slab edge, turns under slab and extends 4' horizontally, any floor cover, R-10 insulation, passive, heavy dry or light wet soil, U-value 0.343 40 1,194 0 0 0 Subtotals for structure:29,949 0 10,383 10,383 People:5 1,000 1,150 2,150 Equipment:0 2,400 2,400 Lighting:0 0 0 Ductwork:0 0 0 0 Infiltration: Winter CFM: 97, Summer CFM: 52 8,979 804 719 1,523 Ventilation: Winter CFM: 145, Summer CFM: 145 5,385 2,249 805 3,054 Exhaust: Winter CFM: 145, Summer CFM: 145 Total Building Load Totals:44,313 4,053 15,457 19,510 Check Figures Total Building Supply CFM:686 CFM Per Square ft.:0.225 Square ft. of Room Area:3,055 Square ft. Per Ton:1,879 Volume (ft³):20,723 Building Loads Total Heating Required Including Ventilation Air:44,313 Btuh 44.313 MBH Total Sensible Gain:15,457 Btuh 79 % Total Latent Gain:4,053 Btuh 21 % Total Cooling Required Including Ventilation Air:19,510 Btuh 1.63 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\Mid State Pl ... od Hills.rh9 Wednesday, February 2, 2022, 1:42 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth)Mid State Plumbing & Heating Plymouth, MN 55441 Page 7 Building Pie Chart Building Loss 44,313 Btuh Floor 8% Roof 6% Wall 33% Glass 17% Door 3% Infiltration 20% Ventilation 12% Building Gain 19,510 Btuh Roof 8% Wall 9% Glass 35% Door 2% People 11% Equipment 12% Infiltration 8% Ventilation 16% C:\ ...\Mid State Pl ... od Hills.rh9 Wednesday, February 2, 2022, 1:42 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth)Mid State Plumbing & Heating Plymouth, MN 55441 Page 8 Detailed Room Loads - Room 1 - Lower Level (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:38.1 ft.System Number:1 Room Width:40.0 ft.Zone Number:1 Area:1,524.0 sq.ft.Supply Air:216 CFM Ceiling Height:9.0 ft.Supply Air Changes:0.9 AC/hr Volume:13,716 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:2 Actual Winter Vent.:61 CFM Runout Air:108 CFM Percent of Supply.:28 % Runout Duct Size:7 in.Actual Summer Vent.:46 CFM Runout Air Velocity:404 ft./min.Percent of Supply:21 % Runout Air Velocity:404 ft./min.Actual Winter Infil.:32 CFM Actual Loss:0.083 in.wg./100 ft.Actual Summer Infil.:17 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain SW-Wall-15B0-10sf-8 40 X 9 360 0.050 4.7 1,680 0.1 0 31 NW-Wall-15B0-10sf-8 26 X 9 234 0.050 4.7 1,092 0.1 0 20 NW-Wall-15B0-10sf-4 14 X 4 56 0.054 4.7 263 0.0 0 0 NW-Wall-12F-0sw 14 X 5 70 0.065 5.7 396 0.9 0 61 NW-Wall-12F-0sw 4 X 9 36 0.065 5.7 204 0.9 0 31 NE-Wall-12F-0sw 40 X 9 290.4 0.065 5.7 1,642 0.9 0 251 SE-Wall-12F-0sw 17.5 X 9 157.5 0.065 5.7 891 0.9 0 136 SE-Wall-15B0-10sf-4 12.5 X 4 50 0.054 4.7 235 0.0 0 0 SE-Wall-12F-0sw 12.5 X 5 49.8 0.065 5.7 281 0.9 0 43 SE-Wall-15B0-10sf-8 14 X 9 126 0.050 4.7 588 0.1 0 11 NE-Gls-Marvin shgc-0.34 0%S (2)27.6 0.320 27.8 770 24.8 0 684 NE-Gls-Marvin shgc-0.34 0%S 42 0.320 27.8 1,169 24.7 0 1,039 SE-Gls-Marvin shgc-0.34 0%S 12.8 0.320 27.8 355 31.8 0 405 Floor-21B-20 40 X 38.1 1524 0.019 1.7 2,519 0.0 0 0 Floor-22D-10pm 40 ft..Per. 40 0.343 29.8 1,194 0.0 0 0 Subtotals for Structure:13,279 0 2,712 Infil.: Win.: 32.5, Sum.: 17.4 765 3.943 3,017 0.316 270 242 People: 200 lat/per, 230 sen/per:2 400 460 Equipment:0 1,200 Room Totals:16,296 670 4,614 C:\ ...\Mid State Pl ... od Hills.rh9 Wednesday, February 2, 2022, 1:42 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth)Mid State Plumbing & Heating Plymouth, MN 55441 Page 9 Detailed Room Loads - Room 2 - Main Level (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:38.3 ft.System Number:1 Room Width:40.0 ft.Zone Number:1 Area:1,531.2 sq.ft.Supply Air:470 CFM Ceiling Height:9.0 ft.Supply Air Changes:2.0 AC/hr Volume:13,781 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:5 Actual Winter Vent.:84 CFM Runout Air:94 CFM Percent of Supply.:18 % Runout Duct Size:6 in.Actual Summer Vent.:99 CFM Runout Air Velocity:479 ft./min.Percent of Supply:21 % Runout Air Velocity:479 ft./min.Actual Winter Infil.:64 CFM Actual Loss:0.143 in.wg./100 ft.Actual Summer Infil.:34 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain SW-Wall-12F-0sw 40 X 9 286.5 0.065 5.7 1,620 0.9 0 248 NW-Wall-12F-0sw 44 X 9 377 0.065 5.7 2,132 0.9 0 326 NE-Wall-12F-0sw 40 X 9 262.1 0.065 5.7 1,482 0.9 0 227 SE-Wall-12F-0sw 44 X 9 378.5 0.065 5.7 2,140 0.9 0 327 SW-Door-11P 3 X 8 24 0.290 25.2 606 7.0 0 167 SW-Door-11P 3 X 8 24 0.290 25.2 606 7.0 0 167 SW-Gls-Marvin shgc-0.34 0%S (2)22.5 0.320 27.8 626 31.8 0 716 SW-Gls-Marvin shgc-0.34 0%S 3 0.320 27.8 84 31.7 0 95 NW-Gls-Marvin shgc-0.34 0%S 6.2 0.320 27.8 174 24.8 0 155 NW-Gls-Marvin shgc-0.34 0%S 7.5 0.320 27.8 209 24.8 0 186 NW-Gls-Marvin shgc-0.34 0%S (2)5.2 0.320 27.8 146 24.8 0 130 NE-Gls-Marvin shgc-0.34 0%S (2)22.5 0.320 27.8 626 24.7 0 556 NE-Gls-Marvin shgc-0.34 0%S (3)39.4 0.320 27.8 1,095 24.8 0 975 NE-Gls-Marvin shgc-0.34 0%S 24 0.320 27.8 668 24.8 0 594 SE-Gls-Marvin shgc-0.34 0%S 5.2 0.320 27.8 146 31.8 0 167 SE-Gls-Marvin shgc-0.34 0%S 12.2 0.320 27.8 341 31.8 0 389 NE-Gls-Fireplace shgc-0.8 0%S 12 1.250 108.8 1,305 64.7 0 776 UP-Ceil-16B-50 38.3 X 40 1531.2 0.020 1.7 2,664 1.0 0 1,470 Subtotals for Structure:16,670 0 7,671 Infil.: Win.: 64.2, Sum.: 34.4 1,512 3.943 5,962 0.315 534 477 People: 200 lat/per, 230 sen/per:3 600 690 Equipment:0 1,200 Room Totals:22,632 1,134 10,038 C:\ ...\Mid State Pl ... od Hills.rh9 Wednesday, February 2, 2022, 1:42 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth)Mid State Plumbing & Heating Plymouth, MN 55441 Page 10 System 1 Room Load Summary No Room Name Area SF Htg Sens Btuh Min Htg CFM Run Duct Size Run Duct Vel Clg Sens Btuh Clg Lat Btuh Min Clg CFM Act Sys CFM ---Zone 1--- 1 Lower Level 1,524 16,296 218 2-7 404 4,614 670 216 216 2 Main Level 1,531 22,632 303 5-6 479 10,038 1,134 470 470 Ventilation 5,385 805 2,249 System 1 total 3,055 44,313 521 15,457 4,053 686 686 System 1 Main Trunk Size:10x14 in. Velocity:706 ft./min Loss per 100 ft.:0.090 in.wg Cooling System Summary Cooling Tons Sensible/Latent Split Sensible Btuh Latent Btuh Total Btuh Net Required:1.63 79% / 21%15,457 4,053 19,510 Equipment Data Heating System Cooling System Type:Natural Gas Furnace Standard Air Conditioner Model: Indoor Model: Brand: Efficiency:0 AFUE 0 SEER Sound:0 0 Capacity:0 Btuh 0 Btuh Sensible Capacity:n/a 0 Btuh Latent Capacity:n/a 0 Btuh C:\ ...\Mid State Pl ... od Hills.rh9 Wednesday, February 2, 2022, 1:42 PM 10/29/21 X KP