Loading...
HomeMy WebLinkAboutLA202504-Approved plansTB154'-6"10 7 ' 75'-2" 18' - 9 "36'-2"31'-8"186'-6"UMMSPUMCBPVACDPDJB53'-7"SCALE: 3/64" = 1'0"COVER PAGESITE PLAN LAYOUTVICINITY MAPERIC WENDT - 11.360 kW DC, 9.28 kW ACCUSTOMER INFORMATIONNAME:ERIC WENDTADDRESS:44.648450, -93.257285APN: 224747604020DESIGNER /CHECKEDDATE:05/10/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:XCEL (MN)PRN NUMBER:NA20855 INDEPENDENCE AVE,LAKEVILLE, MN 55044, USABY: AST-1SHEET CATALOGINDEX NO.T-1M-1E-1PL-1SSDESCRIPTIONCOVER PAGEMOUNTING DETAILTHREE LINE DIAGRAMWARNING PLACARDSSPEC SHEET(S)SCOPE OF WORKGENERAL SYSTEM INFORMATION:SYSTEM SIZE:11360W DC, 9280W ACMODULES:(32)LG ELECTRONICS INC LG355N1C-A6INVERTER:(32)ENPHASE IQ7PLUS-72-2-USHIGH TEMP: 32°C, LOW TEMP: -27°CAPPLICABLE CODES·FIRE CODE:IFC 2018·ENERGY CONSERVATION CODE:IECC 2018·BUILDING CODE:IBC 2018·RESIDENTIAL CODE:IRC 2018GENERAL NOTES1.MODULES ARE LISTED UNDER UL 1703 ANDCONFORM TO THE STANDARDS.2.INVERTERS ARE LISTED UNDER UL 1741 ANDCONFORM TO THE STANDARDS.3.DRAWINGS ARE DIAGRAMMATIC, INDICATINGGENERAL ARRANGEMENT OF THE PV SYSTEM ANDTHE ACTUAL SITE CONDITION MIGHT VARY.4.WORKING CLEARANCES AROUND THE NEW PVELECTRICAL EQUIPMENT WILL BE MAINTAINED INACCORDANCE WITH NEC 110.26.5.ALL GROUND WIRING CONNECTED TO THE MAINSERVICE GROUNDING IN MAIN SERVICE PANEL/SERVICE EQUIPMENT.6.ALL CONDUCTORS SHALL BE 600V, 75°CSTANDARD COPPER UNLESS OTHERWISE NOTED.7.WHEN REQUIRED, A LADDER SHALL BE IN PLACEFOR INSPECTION IN COMPLIANCE WITH OSHAREGULATIONS.8.THE SYSTEM WILL NOT BE INTERCONNECTED BYTHE CONTRACTOR UNTIL APPROVAL FROM THELOCAL JURISDICTION AND/OR THE UTILITY.9.ROOF ACCESS POINT SHALL BE LOCATED INAREAS THAT DO NOT REQUIRE THE PLACEMENTOF GROUND LADDERS OVER OPENINGS SUCH ASWINDOWS OR DOORS, AND LOCATED AT STRONGPOINTS OF BUILDING CONSTRUCTION WHERE THEACCESS POINT DOES NOT CONFLICT WITHOVERHEAD OBSTRUCTIONS SUCH AS TREES,WIRES OR SIGNS.10.PV ARRAY COMBINER/JUNCTION BOXPROVIDES TRANSITION FROM ARRAY WIRING TOCONDUIT WIRING·ELECTRIC CODE:NEC 2017VISIBLE, LOCKABLE, LABELED AC DISCONNECT ISLOCATED WITHIN 10 FEET OF THE UTILITY METERPROPERTY LINEPHOTOVOLTAIC ARRAYON THE ROOF(N) ENPHASE COMBINER PANELWITH ENVOY-IQ METER(E) UTILITY METER(UNDERGROUND FED)(N) VISIBLE, LOCABLE AND LABELLED ACDISCONNECT WITHIN 10' OF UTILITY METER(E) MAIN SERVICE PANEL,200A RATED,240V(INSIDE GARAGE)18" FIRE SETBACK3' FIRE SETBACKJUNCTION BOX(TYPICAL)CONDUIT RUN(N) PROTECTIVE DEVICE WITH BREAKER(N) DER PRODUCTION METER(N) POLARIS TAP BOXDRIVEWAYIN D E P E N D E N C E A V E FENCE LINE208TH ST WM-2STRUCTURAL DETAIL5/19/2022 CUSTOMER INFORMATIONNAME:ERIC WENDTADDRESS:44.648450, -93.257285APN: 224747604020DESIGNER /CHECKEDDATE:05/10/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:XCEL (MN)PRN NUMBER:NA20855 INDEPENDENCE AVE,LAKEVILLE, MN 55044, USABY: ASM-1SCALE: 3/32" = 1'-0"MOUNTING DETAILINSTALLATION NOTES1.STRUCTURAL ROOF MEMBER LOCATIONS AREESTIMATED AND SHOULD BE LOCATED AND VERIFIEDBY THE CONTRACTOR WHEN LAG BOLT PENETRATIONOR MECHANICAL ATTACHMENT TO THE STRUCTURE ISREQUIRED.2.ROOFTOP PENETRATIONS FOR SOLAR RACKING WILLBE COMPLETED AND SEALED WITH APPROVED SEALANTPER CODE BY A LICENSED CONTRACTOR.3.LAGS MUST HAVE A MINIMUM 2.5" THREADEMBEDMENT INTO THE STRUCTURAL MEMBER.4.ALL PV RACKING ATTACHMENTS SHALL BESTAGGERED BY ROW BETWEEN THE ROOF FRAMINGMEMBERS AS NECESSARY.5.ROOF MOUNTED STANDARD RAIL REQUIRES ONETHERMAL EXPANSION GAP FOR EVERY RUN OF RAILGREATER THAN 40'.6.ALL CONDUCTORS AND CONDUITS ON THE ROOFSHALL BE MINIMUM 7/8" ABOVE THE ROOF SURFACE(INCLUDING CABLES UNDERNEATH MODULES ANDRACKING).7.THE PV INSTALLATION SHALL NOT OBSTRUCT ANYPLUMBING, MECHANICAL OR BUILDING ROOF VENTS.ROOF ACCESS PATHWAYS AND SETBACKS:1204.2.1 SOLAR PHOTOVOLTAIC SYSTEMS FOR GROUPR-3BUILDINGS.SOLAR PHOTOVOLTAIC SYSTEMS FORGROUP R-3 BUILDINGS SHALL COMPLY WITH SECTIONS1204.2.1.1 THROUGH 1204.2.1.3.EXCEPTIONS:1.THESE REQUIREMENTS SHALL NOT APPLY TOSTRUCTURES DESIGNED AND CONSTRUCTED INACCORDANCE WITH THE INTERNATIONAL RESIDENTIALCODE.2.THESE REQUIREMENTS SHALL NOT APPLY TO ROOFSWITH SLOPES OF 2 UNITS VERTICAL IN 12 UNITSHORIZONTAL OR LESS.1204.2.1.1 PATHWAYS TO RIDGE. NOT FEWER THANTWO 36-INCH-WIDE (914 MM) PATHWAYS ON SEPARATEROOF PLANES,FROM LOWEST ROOF EDGE TO RIDGE,SHALL BE PROVIDED ON ALL BUILDINGS. NOT FEWERTHAN ONE PATHWAY SHALL BE PROVIDED ON THESTREET OR DRIVEWAY SIDE OF THE ROOF. FOR EACHROOF PLANE WITH A PHOTOVOLTAIC ARRAY, NOTFEWER THAN ONE 36-INCH-WIDE (914 MM) PATHWAYFROM LOWEST ROOF EDGE TO RIDGE SHALL BEPROVIDED ON THE SAME ROOF PLANE AS THEPHOTOVOLTAIC ARRAY, ON AN ADJACENT ROOF PLANEOR STRADDLING THE SAME AND ADJACENT ROOFPLANES1204.2.1.2 SETBACKS AT RIDGE.FOR PHOTOVOLTAICARRAYS OCCUPYING 33 PERCENT OR LESS OF THE PLANVIEW TOTAL ROOF AREA,A SETBACK OF NOT LESS THAN 18 INCHES (457MM)WIDE IS REQUIRED ON BOTH SIDES OF AHORIZONTAL RIDGE. FOR PHOTOVOLTAIC ARRAYSOCCUPYING MORE THAN 33 PERCENT OF THE PLANVIEW TOTAL ROOF AREA, A SETBACK OF NOT LESSTHAN 36 INCHES (457 MM) WIDE IS REQUIRED ONBOTH SIDES OF A HORIZONTAL RIDGE.1204.2.2 EMERGENCY ESCAPE AND RESCUE OPENINGS.PANELS AND MODULES INSTALLED ON GROUP R-3BUILDINGS SHALL NOT BE PLACED ON THE PORTION OFA ROOF THAT IS BELOW AN EMERGENCY ESCAPE ANDRESCUE OPENING. A PATHWAY OF NOT LESS THAN 36INCHES (914 MM) WIDE SHALL BE PROVIDED TO THEEMERGENCY ESCAPE AND RESCUE OPENING1204.2.1.3 ALTERNATIVE SETBACKS AT RIDGE.WHERE AN AUTOMATIC SPRINKLER SYSTEM ISINSTALLED WITHIN THE DWELLING IN ACCORDANCEWITH SECTION 903.3.1.3, SETBACKS AT THE RIDGESHALL CONFORM TO ONE OF THE FOLLOWING:1.FOR PHOTOVOLTAIC ARRAYS OCCUPYING 66 PERCENTOR LESS OF THE PLAN VIEW TOTAL ROOF AREA, ASETBACK OF NOT LESS THAN 18 INCHES (457 MM)WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTALRIDGE.2.FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN66 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, ASETBACK OF NOT LESS THAN 36 INCHES (914 MM)WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTALRIDGEAERIAL VIEWSITE INFORMATION - WIND SPEED: 115 MPH AND SNOW LOAD: 50 PSF(70) UNIRAC ROOF TECH RT-MINIATTACHMENT @48" O.C.NOTE:PENETRATIONS ARE STAGGERED(N)UNIRAC RAILSR. NOARRAYTILTAZIMUTHNO. OFMODULESARRAYAREA(SQ. FT.)ROOF TYPE ATTACHMENTROOFEXPOSUREFRAME TYPEFRAMESIZEFRAMESPACINGMAX RAILSPANOVERHANGMP-0131°214°12223.07ASPHALTSHINGLESUNIRAC ROOFTECH RT MINIATTICTRUSS2"x4"4'-0" 2'-0"ARRAY MP-01MP-0231°214°20 371.78ASPHALTSHINGLESUNIRAC ROOFTECH RT MINIATTICTRUSS2"x4"4'-0" 2'-0"2"X4" TRUSS@ 2'-0" O.C. SPACINGARRAY MP-022'-0"2'-0"3' 3'3'3'5/19/2022 6"STRUCTURAL DETAILCUSTOMER INFORMATIONNAME:ERIC WENDTADDRESS:44.648450, -93.257285APN: 224747604020DESIGNER /CHECKEDDATE:05/10/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:XCEL (MN)PRN NUMBER:NA20855 INDEPENDENCE AVE,LAKEVILLE, MN 55044, USABY: ASM-2ATTACHMENT DETAILMODULES DATALG Electronics Inc LG355N1C-A6MODULE DIMS66.92"x40"x1.57"1ATTACHMENT DETAILM-2SCALE: NTSSEE (2/PV-5) FORENLARGED VIEW(E) COMP SHINGLE ROOF(N) SOLAR MODULE(E) 2"X4" TRUSS @ 2'-0" O.CRT-MINI L-FOOTSOLAR MOUNTUNIRAC RAILM-2SCALE: NTSATTACHMENT DETAIL (Top view)M-2SCALE: NTS2GROUNDING END/MID CLAMP(N) SOLAR MODULE5/16"x4" SS LAG BOLT WITH MIN3" THREAD EMBEDMENT, SEALEDPENETRATIONW5/16" OR M8 HEX BOLTSOLAR MOUNTUNIRAC RAIL(E) COMP SHINGLE ROOF(E) 2"X4" TRUSS @ 2'-0" O.CRT-MINIRT-MINIUNIRAC MODULECLAMP w/ 516" BOLTAND LOCK WASHERBOTTOM MOUNTING CLIP5/19/2022RT MINI ATTACHMENTS MUST BE LAGGED INTO THE ROOF FRAMING CUSTOMER INFORMATIONNAME:ERIC WENDTADDRESS:44.648450, -93.257285APN: 224747604020DESIGNER /CHECKEDDATE:05/10/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:XCEL (MN)PRN NUMBER:NA20855 INDEPENDENCE AVE,LAKEVILLE, MN 55044, USABY: ASE-1THREE LINE DIAGRAMTHREE LINE DIAGRAM: DC SYSTEM SIZE - 11360W, AC SYSTEM SIZE - 9280WMODULE SPECIFICATIONMODELMODULE POWER @ STCOPEN CIRCUIT VOLTAGE:VocMAX POWER VOLTAGE:VmpSHORT CIRCUIT VOLTAGE:IscMAX POWER CURRENT:ImpLG ELECTRONICS INCLG355N1C-A6355W41.5V34.7V10.80A10.25AELECTRICAL CALCULATIONSDC WIRE SIZING CALCULATIONS BASED OF FOLLOWING EQUATIONS>>· REQUIRED CONDUCTOR AMPACITY: 125% PER 690.8(A)(1) X Isc(A) X #OFPARALLEL STRINGS = MAX CURRENT PER 690.8(A)(1) X 125% PER690.8(B)(2)(a)=MAX CURRENT PER 690.8(B)(2)(a)· CORRECTED AMPACITY CALCULATIONS:AMPACITY X TEMPERATURE DERATEFACTOR X CONDUIT FILL DERATE = DERATED CONDUCTOR AMPACITY· DERATED CONDUCTOR AMPACITY CHECK: MAX CURRENT PER 690.8(B)(2)(2) <DERATED CONDUCTOR AMPACITYAC WIRE SIZING CALCULATIONS BASED OF FOLLOWING EQUATIONS >>· REQUIRED CONDUCTOR AMPACITY: INVERTER OUTPUT CURRENT X #OFINVERTERSXMAX CURRENT PER 690.8(A)(3)X125% PER 690.8(B)(2)(A)· CORRECTED AMPACITY CALCULATIONS:AMPACITY X TEMPERATURE DERATEFACTOR X CONDUIT FILL DERATE = DERATED CONDUCTOR AMPACITY· DERATED CONDUCTOR AMPACITY CHECK: MAX CURRENT PER 690.8(B)(2)(2) <DERATED CONDUCTOR AMPACITYAC WIRE CALCULATIONS:- MATERIAL:COPPER & TEMPERATURE RATING:90°CTAG IDREQUIRED CONDUCTOR AMPACITYTAG IDCORRECTED AMPACITY CALCULATIONELECTRICAL NOTES1.CONDUCTORS EXPOSED TO SUNLIGHTSHALL BE LISTED AS SUNLIGHTRESISTANT PER NEC 310.10(D).2.CONDUCTORS EXPOSED TO WETLOCATIONS SHALL BE SUITABLE FOR USEIN WET LOCATIONS PER NEC 310.10(C).3.MAXIMUM DC/AC VOLTAGE DROP SHALLBE NO MORE THAN 2%.4.ALL CONDUCTORS SHALL BE IN CONDUITUNLESS OTHERWISE NOTED.5.BREAKER/FUSE SIZES CONFORMS TONEC 240.6 CODE SECTION.6.ACGROUNDING ELECTRODECONDUCTOR SIZED PER NEC 250.66.7.AMBIENT TEMPERATURE CORRECTIONFACTOR IS BASED ON NEC 690.31(C).8.AMBIENT TEMPERATURE ADJUSTMENTFACTOR IS BASED ON NEC 310.15(B)(2).9.MAX. SYSTEM VOLTAGE CORRECTION ISPER NEC 690.7.10.CONDUCTORS ARE SIZED PER WIREAMPACITY TABLE NEC 310.15(B)(16).12&3.CONDUIT SCHEDULETAG ID123CONDUIT SIZE1" EMT OR EQUIV(2) 6 AWG THHN/THWN-2CONDUCTOR(6)10 AWG THHN/THWN-2NEUTRALNONE(1) 6 AWG THHN/THWN-2GROUND1" EMT OR EQUIV4DERATED CONDUCTOR AMPACITY CHECK(1) 10 AWG THHN/THWN-2(1) 10 AWG THHN/THWN-2(1) 6 AWG BARE CU3/4" EMT OR EQUIV(2) 6 AWG THHN/THWN-2 (1) 6 AWG THHN/THWN-2OCPD CALCULATIONS:INVERTER OVERCURRENT PROTECTION= INVERTER O/P I X CONTINUOUS LOAD(1.25)=32x1.25x1.21 = 48.40A => PV BREAKER = 50ATOTAL REQUIRED PV BREAKER SIZE/FUSED SIZE=>50A PV BREAKERMAIN PANEL RATING: 200A, MAIN REAKER RATING: 200AINVERTER SPECIFICATIONSMODELPOWER RATINGMAX OUTPUT CURRENTCEC WEIGHTED EFFICIENCYMAX INPUT CURRENTMAX DC VOLTAGEENPHASEIQ7PLUS-72-2-US(240V)235W-440W1.21A97%15A PER STRING60V MAXMETER NO.: ACW097413814AC WIRE CALCULATIONS:- MATERIAL:COPPER & TEMPERATURE RATING:90°CREQUIRED CONDUCTOR AMPACITYCORRECTED AMPACITY CALCULATIONDERATED CONDUCTOR AMPACITY CHECK1.62.40A<<1.21 11XX1=40A0.7613.31 X1.25=XX0.8 =24.32A321.21X=1.25X=65X0.96X1=16.64A24.32A16.64A38.7248.40A48.40AMAX OUTPUT POWER290VAVISIBLE, LOCKABLE, LABELED AC DISCONNECT ISLOCATED WITHIN 10 FEET OF THE UTILITY METERNONE62.40AGMNNEW NEMA 3RRATED TAP BOXLINE SIDEINTERCONNECTIONUSING POLARISCONNECTORGEXISTING GROUNDINGELECTRODE SYSTEMBI-DIRECTIONALUTILITY METER1-PHASE, 3-W,120V/240V, 200A(UNDERGROUND FED)L2NL2L1TO UTILITY GRID(E)LINELOAD(E) MAIN SERVICE PANEL200A RATED, 240V(E) MAIN BREAKER TOHOUSE 240 V, 200A/2P(TOP FED)LINE SIDEINTERCONNECTIONAT MAIN PANELPER ART. 705.12(A)(INSIDE GARAGE)LOADLINELOADLINE50A/2PPROTECTIVE DEVICE WITH50A MAIN BREAKERGL1L2NL1L2NBONDEDGL1L2NDER PRODUCTION METER NEMA 3R, UL LISTED200A RATEDGL1L2NMGL1L2NLINELOADL1L1L2L2(MILBANK U4801-XL-5T9)LOADLINEGL1L2NGL1L2NAC DISCONNECT:VISIBLE, LOCKABLE, LABELED60A FUSED, (2) 50A FUSES, 240VNEMA 3R, UL LISTED322BONDED2GNJUNCTION BOX600 V, NEMA 3UL LISTED(3) ENPHASE Q CABLES20A/2PL2L1111 MICROINVERTERS IN BRANCH CIRCUIT 1ENPHASE COMBINER PANEL WITHENVOY IQ METER,(3) 20A / 240VAC CIRCUIT BREAKERS,NEMA 3R, UL LISTED,125A RATED11 MICROINVERTERS IN BRANCH CIRCUIT 2GENVOY IQ(REVENUE GRADE METER)410A/2P20A/2PL2L1LG ELECTRONICS INC LG355N1C-A6ENPHASE IQ7PLUS-72-2-USMICROINVERTERS ONE UNDEREACH PANEL(240V)10 MICROINVERTERS IN BRANCH CIRCUIT 3L2L120A/2PPOC/RPADISTANCE BETWEEN EQUIPMENTUTILITY METER TO TAP BOX6"DISTANCE6"6"TAP BOX TO PROTECTIVE DEVICEPROTECTIVE DEVICE TO DER PRODUCTION METERDER PRODUCTION METER TO AC DISCONNECTAC DISCONNECT TO COMBINER PANEL6"6"STAMPED 05/19/202206/30/2022I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION ORREPORT WAS PREPARED BY ME OR UNDER MY DIRECTSUPERVISION AND THAT I AM A DULY LICENSEDPROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATEOF MINNESOTA.SIGNATURE:____________________________________________NAME:________________________ DATE:________________ LICENSE NUMBER:________ EXP:________________METHODE MANIRAGUHA56543 TBUMMSPUMCBPVACDPDJB CUSTOMER INFORMATIONNAME:ERIC WENDTADDRESS:44.648450, -93.257285APN: 224747604020DESIGNER /CHECKEDDATE:05/10/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:XCEL (MN)PRN NUMBER:NA20855 INDEPENDENCE AVE,LAKEVILLE, MN 55044, USABY: ASPL-1 WARNING PLACARDALL PLACARDS SHALL BE OF WEATHER PROOF CONSTRUCTION, BACKGROUND ON ALL PLACARDS SHALL BERED WITH WHITE LETTERING U.O.N.PLACARD SHALL BE MOUNTED DIRECTLY ON THE EXISTING UTILITY ELECTRICAL SERVICE.FASTENERS APPROVED BY THE LOCAL JURISDICTIONPOWER TO THIS BUILDING IS ALSOSUPPLIED FROM THE FOLLOWINGSOURCES WITH DISCONNECTS LOCATEDAS SHOWNWARNING:!SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWNTURN RAPID SHUTDOWNSWITCH TO THE"OFF" POSITION TOSHUT DOWN THE PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYPLACED ON INVERTERSOLAR ELECTRIC PV PANELS WARNINGELECTRIC SHOCK HAZARDTHE DC CONDUCTORS OF THIS PHOTOVOLTAICSYSTEM ARE UNGROUNDED AND MAY BEENERGIZEDLABEL LOCATIONDC DISCONNECT,INVERTER[PER CODE: NEC 690.41)][To be used when inverter is ungrounded]WARNINGELECTRIC SHOCK HAZARDTERMINALS ON BOTH LINE AND LOAD SIDES MAYBE ENERGIZED IN THE OPEN POSITIONDC VOLTAGE IS ALWAYS PRESENT WHEN SOLARMODULES ARE EXPOSED TO SUNLIGHTLABEL LOCATIONAC DISCONNECT,POINT OF INTERCONNECTION[PER CODE: NEC 690.13(B)] WARNINGELECTRIC SHOCK HAZARDTERMINALS ON BOTH LINE AND LOAD SIDESMAY BE ENERGIZED IN THE OPEN POSITIONLABEL LOCATIONAC DISCONNECT,POINT OF INTERCONNECTION[PER CODE: NEC 690.13(B)]WARNING-ELECTRIC SHOCK HAZARDNO USER SERVICEABLE PARTS INSIDECONTACT AUTHORIZED SERVICEPROVIDE FOR ASSISTANCELABEL LOCATIONINVERTER, JUNCTION BOXES(ROOF),AC DISCONNECT[PER CODE: NEC 690.13]WARNING:PHOTOVOLTAICPOWER SOURCELABEL LOCATIONCONDUIT, COMBINER BOX[PER CODE: NEC690.31(G)(3)]CAUTION: SOLAR ELECTRICSYSTEM CONNECTEDLABEL LOCATIONWEATHER RESISTANT MATERIAL, DURABLE ADHESDIVE,UL969 AS STANDARD TO WEATHER RATING (UL LISTINGOF MARKINGS NOT REQUIRED), MIN 38" LETTER HEIGHTARIAL OR SIMILAR FONT NON-BOLD,PLACED WITHINTHE MAIN SERVICE DISCONNECT,PLACED ON THEOUTSIDE OF THE COVER WHEN DISCONNECT ISOPERATED WITH THE SERVICE PANEL CLOSED.(PER CODE: NEC690.15 ,690.13(B))RAPID SHUTDOWNSWITCH FOR SOLAR PVSYSTEMLABEL LOCATIONINVERTER[PER CODE: NEC 690.56(C)(3)]PHOTOVOLTAIC SYSTEM AC DISCONNECT SWITCHRATED AC OPERATING CURRENTAC NOMINAL OPERATING VOLTAGELABEL LOCATIONAC DISCONNECT , POINT OF INTERCONNECTION[PER CODE: NEC 690.54]WARNINGPOWER SOURCE OUTPUTCONNECTIONDO NOT RELOCATE THISOVER-CURRENT DEVICELABEL LOCATIONPOINT OF INTERCONNECTION(PER CODE: NEC 705.12(b)(2)(3)(b)[ Not Required if Panel board is rated not less than sum ofampere ratings of all overcurrent devices supplying it]CAUTION: SOLAR CIRCUITLABEL LOCATIONMARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC CONDUIT,RACEWAYS, ENCLOSURES AND CABLE ASSEMBLES AT LEAST EVERY10 FT, AT TURNS AND ABOVE/BELOW PENETRATIONS AND ALLCOMBINER/JUNCTION BOXES.(PER CODE: IFC605.11.1.4)SOLAR DISCONNECTLABEL LOCATIONDISCONNECT, POINT OF INTERCONNECTION[PER CODE: NEC690.13(B)]WARNINGDUAL POWER SOURCE SECONDSOURCE IS PHOTOVOLTAICSYSTEMLABEL LOCATIONPOINT OF INTERCONNECTION[PER CODE: NEC705.12(D)(4)]48.40240AMPS ACVAC!!!!(E) MAIN SERVICE PANEL(INSIDE GARAGE)PHOTOVOLTAICAC DISCONNECTAT EACH AC DISCONNECTWARNING PLACARD(E) UTILITY METER(N) AC DISCONNECT(N) COMBINER BOXSOLAR PHOTOVOLTAICROOF MOUNTEDUTILTIYAC DISCONNECTPLACE AT AC DISCONNECTTHE DISCONNECTS LOCATION SHALL BEINCLUDE WITH THE APPLICATION ANDSHALL BE PERMANENTLY AFFIXED TOTHE MAIN REVENUE METERDER PRODUCTIONMETERPLACE AT PRODUCTION METER(N) TAP BOX(N)PROTECTIVE DEVICE(N) DER PRODUCTION METERSTAMPED 05/19/202206/30/2022I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION ORREPORT WAS PREPARED BY ME OR UNDER MY DIRECTSUPERVISION AND THAT I AM A DULY LICENSEDPROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATEOF MINNESOTA.SIGNATURE:____________________________________________NAME:________________________ DATE:________________ LICENSE NUMBER:________ EXP:________________METHODE MANIRAGUHA56543 CUSTOMER INFORMATIONNAME:ERIC WENDTADDRESS:44.648450, -93.257285APN: 224747604020DESIGNER /CHECKEDDATE:05/10/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:XCEL (MN)PRN NUMBER:NA20855 INDEPENDENCE AVE,LAKEVILLE, MN 55044, USABY: ASSS-1 SPEC SHEETMODULE SPEC SHEET CUSTOMER INFORMATIONNAME:ERIC WENDTADDRESS:44.648450, -93.257285APN: 224747604020DESIGNER /CHECKEDDATE:05/10/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:XCEL (MN)PRN NUMBER:NA20855 INDEPENDENCE AVE,LAKEVILLE, MN 55044, USABY: ASSS-2 SPEC SHEETINVERTER SPEC SHEET CUSTOMER INFORMATIONNAME:ERIC WENDTADDRESS:44.648450, -93.257285APN: 224747604020DESIGNER /CHECKEDDATE:05/10/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:XCEL (MN)PRN NUMBER:NA20855 INDEPENDENCE AVE,LAKEVILLE, MN 55044, USABY: ASSS-3 SPEC SHEETCOMBINER BOXSPEC SHEET CUSTOMER INFORMATIONNAME:ERIC WENDTADDRESS:44.648450, -93.257285APN: 224747604020DESIGNER /CHECKEDDATE:05/10/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:XCEL (MN)PRN NUMBER:NA20855 INDEPENDENCE AVE,LAKEVILLE, MN 55044, USABY: ASSS-4 SPEC SHEETMOUNT SPEC SHEET CUSTOMER INFORMATIONNAME:ERIC WENDTADDRESS:44.648450, -93.257285APN: 224747604020DESIGNER /CHECKEDDATE:05/10/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:XCEL (MN)PRN NUMBER:NA20855 INDEPENDENCE AVE,LAKEVILLE, MN 55044, USABY: ASSS-5 SPEC SHEETMOUNT SPEC SHEET CUSTOMER INFORMATIONNAME:ERIC WENDTADDRESS:44.648450, -93.257285APN: 224747604020DESIGNER /CHECKEDDATE:05/10/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:XCEL (MN)PRN NUMBER:NA20855 INDEPENDENCE AVE,LAKEVILLE, MN 55044, USABY: ASSS-6 SPEC SHEETMOUNT SPEC SHEET CUSTOMER INFORMATIONNAME:ERIC WENDTADDRESS:44.648450, -93.257285APN: 224747604020DESIGNER /CHECKEDDATE:05/10/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:XCEL (MN)PRN NUMBER:NA20855 INDEPENDENCE AVE,LAKEVILLE, MN 55044, USABY: ASSS-7 SPEC SHEETMOUNT SPEC SHEET CUSTOMER INFORMATIONNAME:ERIC WENDTADDRESS:44.648450, -93.257285APN: 224747604020DESIGNER /CHECKEDDATE:05/10/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:XCEL (MN)PRN NUMBER:NA20855 INDEPENDENCE AVE,LAKEVILLE, MN 55044, USABY: ASSS-8 SPEC SHEETMOUNT SPEC SHEET CUSTOMER INFORMATIONNAME:ERIC WENDTADDRESS:44.648450, -93.257285APN: 224747604020DESIGNER /CHECKEDDATE:05/10/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:XCEL (MN)PRN NUMBER:NA20855 INDEPENDENCE AVE,LAKEVILLE, MN 55044, USABY: ASSS-9 SPEC SHEETMOUNT SPEC SHEET CUSTOMER INFORMATIONNAME:ERIC WENDTADDRESS:44.648450, -93.257285APN: 224747604020DESIGNER /CHECKEDDATE:05/10/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:XCEL (MN)PRN NUMBER:NA20855 INDEPENDENCE AVE,LAKEVILLE, MN 55044, USABY: ASSS-10 SPEC SHEETMOUNT SPEC SHEET CUSTOMER INFORMATIONNAME:ERIC WENDTADDRESS:44.648450, -93.257285APN: 224747604020DESIGNER /CHECKEDDATE:05/10/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:XCEL (MN)PRN NUMBER:NA20855 INDEPENDENCE AVE,LAKEVILLE, MN 55044, USABY: ASSS-11 SPEC SHEETAC DISCONNECT &JUNCTION BOX SPEC SHEET CUSTOMER INFORMATIONNAME:ERIC WENDTADDRESS:44.648450, -93.257285APN: 224747604020DESIGNER /CHECKEDDATE:05/10/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:XCEL (MN)PRN NUMBER:NA20855 INDEPENDENCE AVE,LAKEVILLE, MN 55044, USABY: ASSS-12 SPEC SHEET DER PRODUCTIONMETER