Loading...
HomeMy WebLinkAboutLA20349 - Approved Plans 20934 Guthrie Dr1.1.1PROJECT NOTES:1.1.2 THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE(NEC) ARTICLE 690, ALL MANUFACTURERS’S LISTING AND INSTALLATION INSTRUCTIONS,AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAVING JURISDICTION’S(AHJ) APPLICABLE CODES.1.1.3 THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEMINSPECTED PRIOR TO PARALLEL OPERATION1.1.4 GROUND FAULT DETECTION AND INTERRUPTION (GFDI) DEVICE IS INTEGRATED WITHTHE MICROINVERTER IN ACCORDANCE WITH NEC 690.41(B)1.1.5 ALL PV SYSTEM COMPONENTS; MODULES, UTILITY-INTERACTIVE INVERTERS, ANDSOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND LISTED FOR USE INPHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC 690.4: PV MODULES: UL1703, IEC61730, AND IEC61215, AND NFPA 70 CLASS C FIRE INVERTERS: UL 1741 CERTIFIED, IEEE 1547, 929, 519 COMBINER BOX(ES): UL 1703 OR UL 1741 ACCESSORY1.1.6 MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENTFOR VOC. IF UNAVAILABLE, MAX DC VOLTAGE CALCULATED ACCORDING TO NEC 690.7.1.1.7 ALL INVERTERS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AND SOURCECIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BEIDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4 (D). SHALL BE INSTALLEDACCORDING TO ANY INSTRUCTIONS FROM LISTING OR LABELING [NEC 110.3].1.1.8 ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. IF EXPOSEDTO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SIGNAGE WILL BEINSTALLED AS REQUIRED BY THE NEC AND AHJ.1.2.1 SCOPE OF WORK:1.2.2 PRIME CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND SPECIFICATIONS OF THEGRID-TIED PHOTOVOLTAIC SYSTEM RETROFIT. PRIME CONTRACTOR WILL BERESPONSIBLE FOR COLLECTING EXISTING ONSITE REQUIREMENTS TO DESIGN,SPECIFY, AND INSTALL THE EXTERIOR ROOF-MOUNTED PORTION OF THEPHOTOVOLTAIC SYSTEMS DETAILED IN THIS DOCUMENT.1.3.1 WORK INCLUDES:1.3.2 PV ROOF ATTACHMENTS - IRONRIDGE FLASHFOOT21.3.3 PV RACKING SYSTEM INSTALLATION - IRONRIDGE XR-1001.3.4 PV MODULE AND INVERTER INSTALLATION - SILFAB SIL-380BK / ENPHASEIQ7PLUS-72-2-US1.3.5 PV EQUIPMENT GROUNDING1.3.6 PV SYSTEM WIRING TO A ROOF-MOUNTED JUNCTION BOX1.3.7 PV LOAD CENTERS (IF INCLUDED)1.3.8 PV METERING/MONITORING (IF INCLUDED)1.3.9 PV DISCONNECTS1.3.10 PV GROUNDING ELECTRODE & BONDING TO (E) GEC1.3.11 PV FINAL COMMISSIONING1.3.12 (E) ELECTRICAL EQUIPMENT RETROFIT FOR PV1.3.13 SIGNAGE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODEGENERAL NOTESN2017MSCOPE OF WORKSYSTEM SIZE: STC: 18 X 380W = 6.840KWPTC: 18 X 354.4W = 6.379KW(18) SILFAB SIL-380BK(18) ENPHASE IQ7PLUS-72-2-USATTACHMENT TYPE: IRONRIDGE FLASHFOOT2MSP UPGRADE: NOINTERCONNECTION TYPE: LOAD SIDE TAP IN METEROWNERNAME:ROBERT ROODPROJECT MANAGERNAME:KEVIN VICKERSPHONE: (763) 412 5714MAIL:KEVIN@GOLDENELECTRICMN.COMCONTRACTORNAME:GOLDEN ELECTRICPHONE: (763) 412-5714AUTHORITIES HAVING JURISDICTIONBUILDING: CITY OF LAKEVILLEZONING: CITY OF LAKEVILLEUTILITY: XCEL ENERGYDESIGN SPECIFICATIONSOCCUPANCY: IICONSTRUCTION: SINGLE-FAMILYZONING:RESIDENTIALGROUND SNOW LOAD: 50 PSFWIND EXPOSURE: ВWIND SPEED: 115 MPHAPPLICABLE CODES & STANDARDSBUILDING: MSBC 2020, MSRC 2020ELECTRICAL: NEC 2017FIRE:MSFC 2020PROJECT INFORMATIONNEW PV SYSTEM:6.840 KWP DC / 5.220 KWP ACROOD RESIDENCE20934 GUTHRIE DRLAKEVILLE, MN 55044ASSESSOR'S #: 221674101160BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORD04.18.2022DESIGN BY:P.V.M.M.PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORGOLDEN ELECTRICPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:ADDRESS:(763) 412-5714EA7686744250 INLAND LANE NPLYMOUTH, MN 55446CASE# 04970605NEW PV SYSTEM:6.840 kWp DC / 5.220 kWp ACROODRESIDENCE20934 GUTHRIE DRLAKEVILLE, MN 55044APN: 221674101160T-001.00COVER PAGE(SHEET 1)01AERIAL PHOTONOT TO SCALENEWS02PLAT MAPNOT TO SCALESHEET LIST TABLESHEET NUMBERSHEET TITLET-001COVER PAGEG-001NOTESA-101SITE PLANA-102ELECTRICAL PLANA-103SOLAR ATTACHMENT PLANE-601LINE DIAGRAME-602DESIGN TABLESE-603PLACARDS 1E-604PLACARDS 2S-501ASSEMBLY DETAILSR-001RESOURCE DOCUMENTR-002RESOURCE DOCUMENTR-003RESOURCE DOCUMENTR-004RESOURCE DOCUMENTR-005RESOURCE DOCUMENTR-006RESOURCE DOCUMENTR-007RESOURCE DOCUMENTR-008RESOURCE DOCUMENTGUTHRIE DRNOTE: POSITION, DISTANCE AND CLEARANCECONCERNS OF OVERHEAD ELECTRIC SERVICELINES AND/OR OTHER UTILITIES IN RELATION TOTHE PV PANELS : NONETO THE NEAREST CROSS STREETHARTFORD WAY 279'Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode06/24/2022dmathews 2.1.1SITE NOTES:2.1.2 A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHAREGULATIONS.2.1.3 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM ISA UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES.2.1.4 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING,MECHANICAL, OR BUILDING ROOF VENTS.2.1.5 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING ANDPROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTIONNEC 110.26.2.1.6 ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED INACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'SINSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THEBUILDING OR STRUCTURE.2.2.1EQUIPMENT LOCATIONS:2.2.2 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BYNEC 110.26.2.2.3 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOREXPECTED OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31 (A),(C)AND NEC TABLES 310.15 (B)(2)(A) AND 310.15 (B)(3)(C).2.2.4 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULESACCORDING TO NEC 690.34.2.2.5 ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTERIS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT.2.2.6 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNELACCORDING TO NEC APPLICABLE CODES.2.2.7 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOROUTDOOR USAGE WHEN APPROPRIATE.2.3.1STRUCTURAL NOTES:2.3.2 RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TOCODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE ADESIGNATED SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND AMINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY,ACCORDING TO RAI MANUFACTURER’S INSTRUCTIONS.2.3.3 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS.IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCALREQUIREMENTS.2.3.4 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED ANDSEALED W/ APPROVED CHEMICAL SEALANT PER CODE BY A LICENSEDCONTRACTOR.2.3.5 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THESPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER.2.3.6 WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BESTAGGERED AMONGST THE ROOF FRAMING MEMBERS.2.4.1WIRING & CONDUIT NOTES:2.4.2 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE.CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODEREQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING.2.4.3 CONDUCTORS SIZED ACCORDING TO NEC 690.8, NEC 690.7.2.4.4 VOLTAGE DROP LIMITED TO 1.5%.2.4.5 DC WIRING LIMITED TO MODULE FOOTPRINT. MICROINVERTER WIRINGSYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/ SUITABLEWIRING CLIPS.2.4.6 AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACK PHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3- BLUE, YELLOW, ORANGE**, OR OTHER CONVENTION NEUTRAL- WHITE OR GRAYIN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGETO BE MARKED ORANGE [NEC 110.15].2.5.1GROUNDING NOTES:2.5.2 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE,AND GROUNDING DEVICES EXPOSED TO THE ELEMENTS SHALL BE RATED FORSUCH USE.2.5.3 PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 ANDMINIMUM NEC TABLE 250.122.2.5.4 METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURESCONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.136(A).2.5.5 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC690.45 AND MICROINVERTER MANUFACTURERS' INSTRUCTIONS.2.5.6 EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS ASSHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IFWEEBS ARE NOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED ATTHE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURERS'INSTALLATION REQUIREMENTS.2.5.7 THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCHTHAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDINGCONDUCTOR TO ANOTHER MODULE.2.5.8 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOREDGREEN OR MARKED GREEN IF #4 AWG OR LARGER [NEC 250.119]2.5.9 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC250.50 THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, ORINADEQUATE, A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TONEC 250, NEC 690.47 AND AHJ.2.5.10 GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.41(B)(1) AND (2) TOREDUCE FIRE HAZARDS2.6.1 DISCONNECTION AND OVER-CURRENT PROTECTION NOTES:2.6.2 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCHIS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TOTHE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS).2.6.3 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BELOCKABLE, AND BE A VISIBLE-BREAK SWITCH2.6.4 PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE ARAPID SHUTDOWN FUNCTION TO REDUCE SHOCK HAZARD FOR EMERGENCYRESPONDERS IN ACCORDANCE WITH 690.12(A) THROUGH (D).2.6.5 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8, 690.9,AND 240.2.6.6 MICROINVERTER BRANCHES CONNECTED TO A SINGLE BREAKER ORGROUPED FUSES IN ACCORDANCE WITH NEC 110.3(B).2.6.7 IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTIONACCORDING TO NEC 690.11 AND UL1699B.2.7.1INTERCONNECTION NOTES:2.7.2 LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH [NEC705.12 (B)]2.7.3 THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAYNOT EXCEED 120% OF BUSBAR RATING [NEC 705.12(D)(2)(3)].2.7.4 THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUITCURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THEBUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THEBUSBAR, PV DEDICATED BACKFEED BREAKERS MUST BE LOCATED OPPOSITEEND OF THE BUS FROM THE UTILITY SOURCE OCPD [NEC 705.12(B)(2)(3)].2.7.5 AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL, TOTALRATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OFBUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BEEXCLUDED ACCORDING TO NEC 705.12 (B)(2)(3)(C).2.7.6 FEEDER TAP INTERCONNECTION (LOAD SIDE) ACCORDING TO NEC 705.12(B)(2)(1)2.7.7 SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.12 (A) WITHSERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230.422.7.8 BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPTFROM ADDITIONAL FASTENING [NEC 705.12 (B)(5)].N2017M N2017M BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORD04.18.2022DESIGN BY:P.V.M.M.PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORGOLDEN ELECTRICPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:ADDRESS:(763) 412-5714EA7686744250 INLAND LANE NPLYMOUTH, MN 55446CASE# 04970605NEW PV SYSTEM:6.840 kWp DC / 5.220 kWp ACROODRESIDENCE20934 GUTHRIE DRLAKEVILLE, MN 55044APN: 221674101160G-001.00NOTES(SHEET 2)NOTE: POSITION, DISTANCE AND CLEARANCECONCERNS OF OVERHEAD ELECTRIC SERVICELINES AND/OR OTHER UTILITIES IN RELATION TOTHE PV PANELS : NONE GENERAL NOTES1. FIELD VERIFY ALL MEASUREMENTS2. ITEMS BELOW MAY NOT BE ON THIS PAGE3. UTILITY AC DISCONNECT AND PV PRODUCTIONMETER ARE LOCATED TOGETHER IN A READILYACCESSIBLE LOCATION WITHIN 10' OF THE MAINSERVICE METER4. 24/7 UNESCORTED KEYLESS ACCESS SHALL BEPROVIDED FOR UTILITY AC DISCONNECT & ALLUTILITY OWNED EQUIPMENTPROPERTY LINEDISTANCESPV SOLAR PANELS - INVERTERS: 2' MAXINVERTERS - AC COMBINER BOX: 45'AC COMBINER BOX - UTILITY NON-FUSED AC DISCONNECT : 2'UTILITY NON-FUSED AC DISCONNECT - PV METER: 2'PV METER - FUSED AC DISCONNECT: 2'FUSED AC DISCONNECT - MAIN ELECTRICAL PANEL: 2'MAIN ELECTRICAL PANEL - BI-DIRECTIONAL METER: 2''BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORD04.18.2022DESIGN BY:P.V.M.M.PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORBLUE OCEAN PROPERTIESPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:PROJECTMANAGER:763-412-5714KEVIN VICKERSEMAIL:KEVIN@GOLDENELECTRICMN.COMCASE# 04970605NEW PV SYSTEM:6.840 kWp DC / 5.220 kWp ACROODRESIDENCE20934 GUTHRIE DRLAKEVILLE, MN 55044APN: 221674101160A-101.00(SHEET 3)AREA OF WORKENTRANCESITE PLAN01/16" = 1'-0"SITE PLAN018' 16'NEWSPROJECT DETAILSCASE# 04970605PROJECT OWNER: ROBERT ROODPROJECT NAME: ROOD RESIDENCEPROJECT ADDRESS: 20934 GUTHRIE DR, LAKEVILLE, MN 55044METERING ARRANGEMENT: NET METERING/BILLINGTO THE NEAREST CROSS STREETHARTFORD WAY 279'NOTE: POSITION, DISTANCE AND CLEARANCECONCERNS OF OVERHEAD ELECTRIC SERVICELINES AND/OR OTHER UTILITIES IN RELATION TOTHE PV PANELS : NONEHOUSE IS UNDER GROUND SERVICE ANDHAS NO CONCERNS OF OVERHEADELECTRIC SERVICE LINE AND / OR OTHERUTILITIES IN RELATION TO PV PANELS24/7 UNESCORTED KEYLESS ACCESSIS TO BE PROVIDED FOR ALL UTILITYEQUIPMENT.(N) (1) FUSED AC DISCONNECT(N) (1) AC COMBINER BOX(REFERENCE OF APPLICABILITY)(N) XCEL ENERGY PV PRODUCTION METEREXTERIOR PV EQUIPMENT(E) (1) MAIN ELECTRICAL PANEL(SECONDARY INTERCONNECTION POINT OFCOMMON COUPLING: LOAD SIDE TAP IN METER)INTERIOR PV EQUIPMENTTHE PV PRODUCTION METER SHALLBE LOCATED WITHIN TEN (10) FEETOF THE EXISTING UTILITY METER≤10(E) XCEL ENERGY BI-DIRECTIONAL METER(N) (1) UTILITY NON-FUSED AC DISCONNECTGUTHRIE DRUNDERGROUND SERVICE DROP - NOOVERHEAD CLEARANCE ISSUES77'-5"20'-4"57'-1"54'-1" MODULE:SILFABSIL-380BK380 WATTS39.98"74.67"GENERAL NOTES1. FIELD VERIFY ALL MEASUREMENTS2. ITEMS BELOW MAY NOT BE ON THIS PAGE3. NO SPECIAL ACCESS INSTRUCTIONSFIRE CLEARANCEMODULE STRINGINGMODULE STRINGINGBFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORD04.18.2022DESIGN BY:P.V.M.M.PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORGOLDEN ELECTRICPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:ADDRESS:(763) 412-5714EA7686744250 INLAND LANE NPLYMOUTH, MN 55446CASE# 04970605NEW PV SYSTEM:6.840 kWp DC / 5.220 kWp ACROODRESIDENCE20934 GUTHRIE DRLAKEVILLE, MN 55044APN: 221674101160A-102.00(SHEET 4)ABELECTRICAL PLAN01/8" = 1'-0"ELECTRICAL PLAN014' 8'NEWS(N) (1) JUNCTION BOXARRAY 1 - 6.840 kW[18] (N) MODULESTILT: 30 DEGREESROOF PITCH: 7:12AZIMUTH: 240 DEGREESNOTE: POSITION, DISTANCE AND CLEARANCECONCERNS OF OVERHEAD ELECTRIC SERVICELINES AND/OR OTHER UTILITIES IN RELATION TOTHE PV PANELS : NONEHOUSE IS UNDER GROUND SERVICE ANDHAS NO CONCERNS OF OVERHEADELECTRIC SERVICE LINE AND / OR OTHERUTILITIES IN RELATION TO PV PANELS24/7 UNESCORTED KEYLESS ACCESSIS TO BE PROVIDED FOR ALL UTILITYEQUIPMENT.(N) (1) FUSED AC DISCONNECT #2(N) (1) AC COMBINER BOX(REFERENCE OF APPLICABILITY)(N) XCEL ENERGY PV PRODUCTION METEREXTERIOR PV EQUIPMENT(E) (1) MAIN ELECTRICAL PANEL(SECONDARY INTERCONNECTION POINT OFCOMMON COUPLING: LOAD SIDE TAP IN METER)INTERIOR PV EQUIPMENTTHE PV PRODUCTION METER SHALLBE LOCATED WITHIN TEN (10) FEETOF THE EXISTING UTILITY METER≤10(E) XCEL ENERGY BI-DIRECTIONAL METER(N) (1) UTILITY NON-FUSED AC DISCONNECT #1BUNDERGROUND SERVICE DROP - NOOVERHEAD CLEARANCE ISSUESА18" FIRE ACCESS PATH18" FIRE ACCESS PATH3' FIRE ACCESS PATHBАBАBАBАBАBАBАBА3' FIRE ACCESS PATH GENERAL NOTES1. FIELD VERIFY ALL MEASUREMENTS2. ITEMS BELOW MAY NOT BE ON THIS PAGEROOF TRUSSESMODULE:SILFABSIL-380BK380 WATTS39.98"74.67''BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORD04.18.2022DESIGN BY:P.V.M.M.PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORGOLDEN ELECTRICPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:ADDRESS:(763) 412-5714EA7686744250 INLAND LANE NPLYMOUTH, MN 55446CASE# 04970605NEW PV SYSTEM:6.840 kWp DC / 5.220 kWp ACROODRESIDENCE20934 GUTHRIE DRLAKEVILLE, MN 55044APN: 221674101160NEWS01/8" = 1'-0"SOLAR ATTACHMENT PLAN014' 8'A-103.00(SHEET 5)SOLAR ATTACHMENT PLANNOTE: POSITION, DISTANCE AND CLEARANCECONCERNS OF OVERHEAD ELECTRIC SERVICELINES AND/OR OTHER UTILITIES IN RELATION TOTHE PV PANELS : NONEFLUSH MOUNT SOLAR MODULESATTACHED TO ROOF SURFACE (SEESHEET S-501 FOR MOUNTING DETAILS)ROOF MATERIAL IS ASPHALT SHINGLE30'-2" G(E)BI-DIRECTIONALMETERTO (E)LOADSKWHR (Е) MAIN 200A[x1] XCEL ENERGY BI-DIRECTIONAL METER240/120V, 1 PHASE, 3W(Е) MAIN ELECTRICAL PANEL240/120 V 1Ø, 3WMAIN BUSS: 200AGSW130A545' MAX 0.75" EMT(4) #10 THWN-2(2) #6 GROUND[x1] UTILITY NON-FUSED AC DISCONNECT240/120V, 30A, 1 PHASE, 3R RATEDNON-FUSED AC DISCONNECT (30A)VISIBLE-OPEN TYPE, LOCKABLE, READILY ACCESSIBLEMAKE: EATONMODEL: DG221URBTO UTILITYGRID (UG)[x1] PV PRODUCTION METER (XCEL ENERGY)MILBANK 200A, 240/120V, 1 PHASE, 3W3GA2TAPSOLAR FRAMING SEPARATELY GROUNDED BY AUX ROD#6 BARE COOPER AUX. GROUND PER NEC 690.47PV PRODUCTION METER NOTES:PV PRODUCTION METER - 200A SELF-CONTAINED METER SOCKET WITHLEVER BYPASS, COMPLIANT WITH THE MOST RECENT REVISION OF THEXCEL ENERGY STANDARD, SPECIFICALLY SECTION 4.11.PV GENERATION WIRED TO THE LINE SIDE TERMINALS.PV PRODUCTION METER TO HAVE STAMPED BRASS, ALUMINUM, ORSTAINLESS STEEL TAG, 4916 APASIA LANE, EDINA, MN 55435 INCLUDINGTHE UNITING NUMBER AND “PV PROD” IN ACCORDANCE WITH THEREQUIREMENTS FOR METER IDENTIFICATION IN SECTION 4.14.4 OF THEXCEL ENERGY STANDARD.LOCATED WITHIN 10’ OF THE EXISTING UTILITY METER[x1] JUNCTION BOX[x18] SOLAR MODULESMAKE: SILFABMODEL: SIL-380BK[x18] MICROINVERTERSMAKE: ENPHASEMODEL: IQ7PLUS-72-2-USRATED POWER: 290W240V, 1 PHASE, 3WCERTIFIED: UL 62109-1, UL1741/IEEE1547GCB120A[X1] АС COMBINER BOXMAKE: ENPHASEMODEL: IQ COMBINER 3-ES240/120V, 125A, 1 PHASE, 3WCB220AIN BRANCH9A1CB315AENPHASE ENVOYCOMMUNICATIONSGATEWAYBMODULE STRINGINGIN BRANCH9В(E) GROUNDINGELECTRODEGROUNDROD! WARNING !DUAL POWER SOURCES.SECOND SOURCE IS PV SYSTEMPHOTOVOLTAICAC DISCONNECT OPERATING CURRENT: 21 .78 A ACOPERATING VOLTAGE: 240 V AC! WARNING !ELECTRIC SHOCK HAZARDTERMINALS ON THE LINE AND LOAD SIDES MAYBE ENERGIZED IN THE OPEN POSITION.DC VOLTAGE IS ALWAYS PRESENT WHENSOLAR MODULES ARE EXPLOSED TO SUNLIGHT! CAUTION !PHOTOVOLTAIC SYSTEMCIRCUIT IS BACKFEDINTERACTIVE PHOTOVOLTAIC SYSTEMCONNECTEDPHOTOVOLTAIC SYSTEM DISCONNECT LOCATEDNW SIDE OF THE HOUSESOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY SO LAR E LECTRICPV PANEL S UTILITYAC DISCONNECTPV PRODUCTIONMETER! WARNING !INVERTER OUTPUT CONNECTION.DO NOT RELOCATE THISOVERCURRENT DEVICELOAD CENTER CONTAINS ONLYGENERATION CIRCUITS, AND NOUNUSED POSITIONS OR LOADS1. PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN DISCONNECTPER NEC 690.132. SYSTEM COMPLIANT WITH ALL CURRENT NEC CODES2' MAX 0.75" EMT(2) #10 THWN-2(1) #6 GROUND2' MAX 0.75" EMT(2) #10 THWN-2(1) #6 GROUND2' MAX 0.75" EMT(2) #6 THWN-2(1) #6 GROUNDPHOTOVOLTAIC SYSTEMEQUIPPED WITH RAPIDSHUTDOWNKWHRLINELOADPHOTOVOLTAIC SYSTEMCONNECTEDАMODULE STRINGINGGGSW260A[x1] FUSED AC DISCONNECT240/120V, 60A, 1 PHASE, 3R RATEDFUSED AC DISCONNECT (60A FUSES 30A)VISIBLE-OPEN TYPE, LOCKABLE, READILY ACCESSIBLEMAKE: EATONMODEL: DG222NRB4F1-230A2' MAX 0.75" EMT(2) #10 THWN-2(1) #6 GROUNDPHOTOVOLTAICAC DISCONNECT OPERATING CURRENT: 21 .78 A ACOPERATING VOLTAGE: 240 V AC! WARNING !ELECTRIC SHOCK HAZARDTERMINALS ON THE LINE AND LOAD SIDES MAYBE ENERGIZED IN THE OPEN POSITION.DC VOLTAGE IS ALWAYS PRESENT WHENSOLAR MODULES ARE EXPLOSED TO SUNLIGHTUTILITYAC DISCONNECTPHOTOVOLTAIC SYSTEMEQUIPPED WITH RAPIDSHUTDOWNNON-SPLICING LUGS/LUG KIT PoC/RPACONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONSID TYPICALCONDUCTORCONDUITCURRENT-CARRYINGCONDUCTORS IN CONDUITOCPDEGCTEMP. CORR.FACTORCONDUIT FILLFACTORCONT.CURRENTMAX. CURRENT(125%)BASE AMP.DERATEDAMP.TERM. TEMP. RATINGAMP. @ TERMINAL1 110 AWG THWN-2, COPPER0.75'' DIA EMT420A6 AWG THWN-2, COPPER0.96 (32.1 °C)0.810.89A 13.61A40A 30.72A75°C35A2 110 AWG THWN-2, COPPER0.75'' DIA EMT2N/A6 AWG THWN-2, COPPER0.96 (32.1 °C)121.78A 27.23A40A38.4A75°C35A3110 AWG THWN-2, COPPER0.75'' DIA EMT2N/A6 AWG THWN-2, COPPER0.96 (32.1 °C)121.78A 27.23A40A38.4A75°C35A4110 AWG THWN-2, COPPER0.75'' DIA EMT230A6 AWG THWN-2, COPPER0.96 (32.1 °C)121.78A 27.23A40A38.4A75°C35A516 AWG THWN-2, COPPER0.75'' DIA EMT2N/A6 AWG THWN-2, COPPER0.96 (32.1 °C)121.78A 27.23A75A72A75°C65AE-601.00(SHEET 6)BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORD04.18.2022DESIGN BY:P.V.M.M.PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORGOLDEN ELECTRICPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:ADDRESS:(763) 412-5714EA7686744250 INLAND LANE NPLYMOUTH, MN 55446CASE# 04970605NEW PV SYSTEM:6.840 kWp DC / 5.220 kWp ACROODRESIDENCE20934 GUTHRIE DRLAKEVILLE, MN 55044APN: 221674101160LINE DIAGRAMNOTE:THE USE OF AN AMMETER: DER OUTPUT OF THE INVERTER HAS CEASEDWITHIN TWO SECONDSNOTE:ONLY CUSTOMER-OWNED EQUIPMENT SHALL BE USED FOR THISVERIFICATIONNOTE:ALL TESTING SHALL BE PERFORMED BY QUALIFIED PERSONNELINVERTER LED’S, ALARMS, AND/OR LCD CODES ARE APPROPRIATE FOR LOSSOF UTILITY SOURCE.ALL DER UNITS ARE OPERATIONAL AND PRODUCING POWERNOTE: POSITION, DISTANCE AND CLEARANCECONCERNS OF OVERHEAD ELECTRIC SERVICELINES AND/OR OTHER UTILITIES IN RELATION TOTHE PV PANELS : NONENOTE:LABELS AND WITNESS TEST PROCEDURE WILL NEED TO BE PROVIDED LATERIN THE PROCESS.MODULES: 18 X 380W = 6.840 KW (STC-DC)INVERTER(S): 18 X 290W = 5.220 KW (AC)PROJECT DETAILSCASE# 04970605PROJECT OWNER: ROBERT ROODPROJECT NAME: ROOD RESIDENCEPROJECT ADDRESS: 20934 GUTHRIE DR, LAKEVILLE, MN 55044METERING ARRANGEMENT: NET METERING/BILLING SYSTEM SUMMARYBRANCH #1BRANCH #2INVERTERS PER BRANCH99MAX AC CURRENT10.89A10.89AMAX AC OUTPUT POWER2,655W2,655WARRAY STC POWER6,840WARRAY PTC POWER6,379WMAX AC CURRENT21.78AMAX AC POWER5,220WDERATED (CEC) AC POWER5,220WDISCONNECTSINVERTERSOCPDSMODULESASHRAE EXTREME LOW-35.2°C (-31.4°F), SOURCE: AIRLAKE (44.63°; -93.22°)ASHRAE 2% HIGH32.1°C (89.8°F), SOURCE: AIRLAKE (44.63°; -93.22°)REF.QTY.RATED CURRENTMAX VOLTAGECB1-2 220A240VACCB3115A240VACF1-2 230A240VACREF.QTY.MAKE AND MODELRATED CURRENT MAX RATED VOLTAGESW1 1EATON DG221URB OR EQUIV.30A240VACSW21EATON DG222NRB OR EQUIV.60A240VACREF.QTY.MAKE AND MODELPMAX PTC ISC IMP VOC VMP TEMP. COEFF. OF VOC FUSE RATINGPM1-18 18SILFAB SIL-380BK380W 354.4W 10.5A 9.79A 45.13V 38.88V-0.126V/°C (-0.28%/°C)20AREF.QTY.MAKE AND MODELACVOLTAGEGROUNDOCPDRATINGRATEDPOWERMAX OUTPUTCURRENTMAX INPUTCURRENTMAX INPUTVOLTAGECEC WEIGHTEDEFFICIENCYI1-18 18ENPHASE IQ7PLUS-72-2-US240VFLOATING20A 290W1.21A15A 60V97.0%E-602.00(SHEET 7)BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORD04.18.2022DESIGN BY:P.V.M.M.PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORGOLDEN ELECTRICPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:ADDRESS:(763) 412-5714EA7686744250 INLAND LANE NPLYMOUTH, MN 55446CASE# 04970605NEW PV SYSTEM:6.840 kWp DC / 5.220 kWp ACROODRESIDENCE20934 GUTHRIE DRLAKEVILLE, MN 55044APN: 221674101160DESIGN TABLESNOTE: POSITION, DISTANCE AND CLEARANCECONCERNS OF OVERHEAD ELECTRIC SERVICELINES AND/OR OTHER UTILITIES IN RELATION TOTHE PV PANELS : NONE GRADE(N) UTILITY NON-FUSEDAC DISCONNECTTO PV ARRAY(E) UTILITYTO (E) MEP(INSIDE)(N) AC COMBINER BOX(Е) XCEL ENERGYBI-DIRECTIONAL METER(N) PV PRODUCTION METER (XCEL ENERGY)(N) FUSEDAC DISCONNECTE-603.00(SHEET 8)BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORD04.18.2022DESIGN BY:P.V.M.M.PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORGOLDEN ELECTRICPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:ADDRESS:(763) 412-5714EA7686744250 INLAND LANE NPLYMOUTH, MN 55446CASE# 04970605NEW PV SYSTEM:6.840 kWp DC / 5.220 kWp ACROODRESIDENCE20934 GUTHRIE DRLAKEVILLE, MN 55044APN: 221674101160PLACARDS 101EQUIPMENT ELEVATIONNOT TO SCALELABELS SHALL BE WEATHERPROOF,DURABLE ANDPERMANENTLY MOUNTEDLABELS COMPLY WITH NEC 690ALL SIGNAGE MUST BEPERMANENTLY ATTACHED AND BEWEATHER RESISTANT/SUNLIGHTRESISTANT AND CANNOT BEHAND-WRITTEN PER NEC 110.21(B)! WARNING !DUAL POWER SOURCES.SECOND SOURCE IS PV SYSTEMLABEL 6PHOTOVOLTAICAC DISCONNECTOPERATING CURRENT: 21.78 A ACOPERATING VOLTAGE: 240 V ACLABEL 5AT POINT OF INTERCONNECTION, MARKEDAT DISCONNECTING MEANS[NEC 690.54]! WARNING !ELECTRIC SHOCK HAZARDTERMINALS ON BOTH LINE AND LOAD SIDESMAY BE ENERGIZED IN THE OPEN POSITION.LABEL 3AT EACH DISCONNECTING MEANS FORPHOTOVOLTAIC EQUIPMENT[NEC 690.13 AND 690.15]PHOTOVOLTAICAC DISCONNECTWARNING: PHOTOVOLTAICPOWER SOURCELABEL 11AT EXPOSED RACEWAYS, CABLE TRAYS, AND OTHER WIRINGMETHODS; SPACED AT MAXIMUM 10 FT SECTION OR WHERESEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS,OR FLOORS.[NEC 690.31(G)]LETTERS AT LEAST 3/8 INCH; WHITE ON RED BACKGROUND;REFLECTIVE[IFC 605.11.1.1]LABEL 12AT EACH AC DISCONNECTING MEANS[NEC 690.13(B)]! CAUTION !PHOTOVOLTAIC SYSTEMCIRCUIT IS BACKFED! WARNING !POWER SOURCE OUTPUTCONNECTION - DO NOT RELOCATETHIS OVERCURRENT DEVISELABEL 13AT POINT OF INTERCONNECTIONOVERCURRENT DEVICE[NEC 705.12(B)(2)(3)(B)]INTERACTIVE PHOTOVOLTAIC SYSTEMCONNECTEDLABEL 8AT UTILITY METER[NEC 690.56(B)]PHOTOVOLTAIC SYSTEMEQUIPPED WITH RAPIDSHUTDOWNLABEL 10AT RAPID SHUTDOWN SWITCH[NEC 690.56(C)].LETTERS AT LEAST 3/8 INCH; WHITE ON REDBACKGROUND; REFLECTIVE[IFC 605.11.1.1]LABEL 7LABELING NOTES1.1 LABELING REQUIREMENTS BASED ON THE 2017 ELECTRICAL CODE, INTERNATIONAL FIRE CODE 605.11, OSHA STANDARD1910.145, ANSI Z5351.2 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION.1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED.1.4 LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8” AND PERMANENTLY AFFIXED.1.5 ALERTING WORDS TO BE COLOR CODED. “DANGER” WILL HAVE RED BACKGROUND; “WARNING” WILL HAVE ORANGEBACKGROUND; “CAUTION” WILL HAVE YELLOW BACKGROUND. [ANSI Z535]DIRECTORYPERMANENT PLAQUE ORDIRECTORY PROVIDINGTHE LOCATION OF THESERVICEDISCONNECTING MEANSAND THE PHOTOVOLTAICSYSTEM DISCONNECTINGMEANS IF NOT IN THESAME LOCATION[NEC 690.56(B)]PLAQUEAT POINT OF INTERCONNECTION; LABEL, SUCH AS LABEL 5 OR LABEL 6 MUST IDENTIFYPHOTOVOLTAIC SYSTEM[NEC 705.12(B)(4)]INTERACTIVE PHOTOVOLTAIC SYSTEMCONNECTEDPHOTOVOLTAIC SYSTEM DISCONNECT LOCATEDNW SIDE OF THE HOUSEWHERE THE PV SYSTEMSARE REMOTELY LOCATEDFROM EACH OTHER, ADIRECTORY INACCORDANCE WITH 705.10SHALL BE PROVIDED ATEACH PV SYSTEMDISCONNECTING MEANS.PV SYSTEM EQUIPMENTAND DISCONNECTINGMEANS SHALL NOT BEINSTALLED IN BATHROOMS[NEC 690.4(D),(E)]SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNTURN RAPID SHUTDOWNSWICH TO THE "OFF"POSITION TO SHUTDOWNPV SYSTEM AND REDUCESHOCK HAZARD IN ARRAYSOLAR ELECTRICPV PANELSLABEL 1AT RAPID SHUTDOWN SYSTEM[NEC 690.56(C)(1)(A)].UTILITYAC DISCONNECTLABEL 14UTILITY AC DISCONNECTNOTE: POSITION, DISTANCE AND CLEARANCECONCERNS OF OVERHEAD ELECTRIC SERVICELINES AND/OR OTHER UTILITIES IN RELATION TOTHE PV PANELS : NONELABEL 15PV PRODUCTION METERLOAD CENTER CONTAINS ONLYGENERATION CIRCUITS, AND NOUNUSED POSITIONS OR LOADSLABEL 16UTILITY AC DISCONNECTLABEL 17PHOTOVOLTAIC AC DISCONNECTPHOTOVOLTAICUTILITY AC DISCONNECTPV PRODUCTION METERLABELS SHALL BE WEATHERPROOF,DURABLE, AND PERMANENTLY MOUNTEDLABELS COMPLY WITH NEC 690 MAIN DISTRIBUTIONUTILITY DISCONNECTFRONTBACK!CAUTION!POWER TO THIS BUILDING IS ALSO SUPPLIEDFROM ROOF MOUNTED SOLAR ARRAYS WITHSAFETY DISCONNECTS AS SHOWN:E-604.00(SHEET 9)BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORD04.18.2022DESIGN BY:P.V.M.M.PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORGOLDEN ELECTRICPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:ADDRESS:(763) 412-5714EA7686744250 INLAND LANE NPLYMOUTH, MN 55446CASE# 04970605NEW PV SYSTEM:6.840 kWp DC / 5.220 kWp ACROODRESIDENCE20934 GUTHRIE DRLAKEVILLE, MN 55044APN: 221674101160NEWSPLACARDS 2NOTE: POSITION, DISTANCE AND CLEARANCECONCERNS OF OVERHEAD ELECTRIC SERVICELINES AND/OR OTHER UTILITIES IN RELATION TOTHE PV PANELS : NONELABELS SHALL BE WEATHERPROOF,DURABLE ANDPERMANENTLY MOUNTEDLABELS COMPLY WITH NEC 690PV ARRAY SHEET KEYNOTES1. ROOF MATERIAL: ASPHALT SHINGLE2. ROOF STRUCTURE: TRUSS3. ATTACHMENT TYPE: IRONRIDGE FLASH FOOT4. MODULE MANUFACTURER: SILFAB5. MODULE MODEL: SIL-380BK6. MODULE LENGTH: 70.67''7. MODULE WIDTH: 39.98''8. MODULE WEIGHT: 41.9 LBS.9. SEE SHEET A-103 FOR DIMENSION(S)10. MIN. FIRE OFFSET: 18" FROM RIDGE, 36" FROM EDGE.11. TRUSS SPACING: 18 IN. O.C.12. TRUSS SIZE: 2X4" NOMINAL13. LAG BOLT DIAMETER: 5/16" IN.14. LAG BOLT EMBEDMENT: 2-3/4" IN.15. TOTAL # OF ATTACHMENTS: 4416. TOTAL AREA: 353.17 SQ. FT.17. TOTAL WEIGHT: 878.6 LBS.18. WEIGHT PER ATTACHMENT: 19.97 LBS.19. DISTRIBUTED LOAD: 2.35 PSF20. MAX. HORIZONTAL STANDOFF: 36 IN.21. MAX. VERTICAL STANDOFF: IN ACCORDANCE WITHMODULE MANUFACTURER'S INSTRUCTIONS.22. STANDOFF STAGGERING: YES23. RAIL MANUFACTURER (OR EQUIV.): IRONRIDGE24. RAIL MODEL (OR EQUIVALENT): XR10025. RAIL WEIGHT: 0.68 PLF.26. MAX. TRUSS SPAN: 20 FT.27. MODULE CLEARANCE: 3 IN. MIN., 6 IN. MAX.S-501D52011121413151822ROOF SLOPE 910106217S-501D4315425242382721. FIELD VERIFY ALL MEASUREMENTSGENERAL NOTESBFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORD04.18.2022DESIGN BY:P.V.M.M.PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORGOLDEN ELECTRICPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:ADDRESS:(763) 412-5714EA7686744250 INLAND LANE NPLYMOUTH, MN 55446CASE# 04970605NEW PV SYSTEM:6.840 kWp DC / 5.220 kWp ACROODRESIDENCE20934 GUTHRIE DRLAKEVILLE, MN 55044APN: 221674101160S-501.00ASSEMBLY DETAILS(SHEET 10)D4DETAIL (TRANSVERSE)NOT TO SCALED5DETAIL (LONGITUDINAL)NOT TO SCALED1RACKING DETAIL (TRANSVERSE)NOT TO SCALED3RACKING DETAIL (TOP)NOT TO SCALED2RACKING DETAIL (LONGITUDINAL)NOT TO SCALENOTE: POSITION, DISTANCE AND CLEARANCECONCERNS OF OVERHEAD ELECTRIC SERVICELINES AND/OR OTHER UTILITIES IN RELATION TOTHE PV PANELS : NONE BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORD04.18.2022DESIGN BY:P.V.M.M.PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORGOLDEN ELECTRICPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:ADDRESS:(763) 412-5714EA7686744250 INLAND LANE NPLYMOUTH, MN 55446CASE# 04970605NEW PV SYSTEM:6.840 kWp DC / 5.220 kWp ACROODRESIDENCE20934 GUTHRIE DRLAKEVILLE, MN 55044APN: 221674101160R-001.00(SHEET 11)RESOURCE DOCUMENT BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORD04.18.2022DESIGN BY:P.V.M.M.PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORGOLDEN ELECTRICPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:ADDRESS:(763) 412-5714EA7686744250 INLAND LANE NPLYMOUTH, MN 55446CASE# 04970605NEW PV SYSTEM:6.840 kWp DC / 5.220 kWp ACROODRESIDENCE20934 GUTHRIE DRLAKEVILLE, MN 55044APN: 221674101160R-002.00(SHEET 12)RESOURCE DOCUMENT BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORD04.18.2022DESIGN BY:P.V.M.M.PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORGOLDEN ELECTRICPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:ADDRESS:(763) 412-5714EA7686744250 INLAND LANE NPLYMOUTH, MN 55446CASE# 04970605NEW PV SYSTEM:6.840 kWp DC / 5.220 kWp ACROODRESIDENCE20934 GUTHRIE DRLAKEVILLE, MN 55044APN: 221674101160R-003.00(SHEET 13)RESOURCE DOCUMENT BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORD04.18.2022DESIGN BY:P.V.M.M.PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORGOLDEN ELECTRICPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:ADDRESS:(763) 412-5714EA7686744250 INLAND LANE NPLYMOUTH, MN 55446CASE# 04970605NEW PV SYSTEM:6.840 kWp DC / 5.220 kWp ACROODRESIDENCE20934 GUTHRIE DRLAKEVILLE, MN 55044APN: 221674101160R-004.00(SHEET 14)RESOURCE DOCUMENT BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORD04.18.2022DESIGN BY:P.V.M.M.PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORGOLDEN ELECTRICPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:ADDRESS:(763) 412-5714EA7686744250 INLAND LANE NPLYMOUTH, MN 55446CASE# 04970605NEW PV SYSTEM:6.840 kWp DC / 5.220 kWp ACROODRESIDENCE20934 GUTHRIE DRLAKEVILLE, MN 55044APN: 221674101160R-005.00(SHEET 15)RESOURCE DOCUMENT BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORD04.18.2022DESIGN BY:P.V.M.M.PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORGOLDEN ELECTRICPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:ADDRESS:(763) 412-5714EA7686744250 INLAND LANE NPLYMOUTH, MN 55446CASE# 04970605NEW PV SYSTEM:6.840 kWp DC / 5.220 kWp ACROODRESIDENCE20934 GUTHRIE DRLAKEVILLE, MN 55044APN: 221674101160R-006.00(SHEET 16)RESOURSE DOCUMENT BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORD04.18.2022DESIGN BY:P.V.M.M.PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORGOLDEN ELECTRICPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:ADDRESS:(763) 412-5714EA7686744250 INLAND LANE NPLYMOUTH, MN 55446CASE# 04970605NEW PV SYSTEM:6.840 kWp DC / 5.220 kWp ACROODRESIDENCE20934 GUTHRIE DRLAKEVILLE, MN 55044APN: 221674101160R-007.00(SHEET 17)RESOURCE DOCUMENT BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORD04.18.2022DESIGN BY:P.V.M.M.PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORGOLDEN ELECTRICPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:ADDRESS:(763) 412-5714EA7686744250 INLAND LANE NPLYMOUTH, MN 55446CASE# 04970605NEW PV SYSTEM:6.840 kWp DC / 5.220 kWp ACROODRESIDENCE20934 GUTHRIE DRLAKEVILLE, MN 55044APN: 221674101160R-008.00(SHEET 18)RESOURCE DOCUMENT System Weight Total system weight 880.9 lbs Weight/attachment 27.5 lbs Racking weight 126.9 lbs Distributed weight 2.5 psf Load Assumptions Wind exposure B Wind speed 115 mph Ground snow load 50 psf Attachment spacing portrait 4.0' Span Details XR100 - Portrait Zone Max span Max cantilever 1 6' 1"2' 5" 2 6' 1"2' 5" 3 6' 1"2' 5" Reaction Forces XR100 - Portrait Zone Down (lbs) Uplift (lbs) Lateral (lbs) 1 415 105 65 2 415 217 65 3 415 345 65 Project Details Name 5400 Main Street Northeast Date 06/17/2022 Location 20934 Guthrie Drive, Lakeville, MN 55044 Total modules 18 Module Silfab: SIL-380-BK (38mm)Total watts 6,840 Dimensions Dimensions: 70.67" x 38.98" x 1.5" (1795.0mm x 990.0mm x 38.0mm)Attachments 32 ASCE 7-10 Rails per row 2 Roof Information Roof Material Family Comp Shingle Roof material Comp Shingle Building height 30 ft Roof attachment Flashfoot2 Roof slope 9 °Attachment hardware Square Risk category II Last updated by andrea russell on 06/17/22 09:07 PM Page 1 of 6 5400 Main Street Northeast (#978659) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Roof Section 1 Details Weights Panels: 18 Provided rail: 124' [4 x 168", 4 x 204"]Total weight: 880.9 lbs Rail orientation: East-West Attachments: 32 Weight/attachment: 27.5 lbs Panel orientation: Portrait Splices: 4 Total Area: 350.2 sq ft Entry type: Graphical Clamps: 40 Distributed weight: 2.5 psf Diagram Segments Identifier Columns Row length Rail length Cantilever Cantilever Violations Rail Attachments Splices Clamps A 9 29' 8"29' 8"10"None 62' [2 x 168", 2 x 204"]16 2 20 Row segment totals (x 2) →124' [4 x 168", 4 x 204"]32 4 40 Contour Plan - Trim Cut List Identifier Scrap from Length Scraps Created Discard 29' 6"11' 10"Last updated by andrea russell on 06/17/22 09:07 PM Page 2 of 6 5400 Main Street Northeast (#978659) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Side View (portrait) 9° BUILDING STRUCTURE ROOF MEMBRANE FLASHFOOT2 RAIL PV MODULE Front View (portrait) ATTACHMENT SPAN 4.0’ BUILDING STRUCTURE ROOF MEMBRANE FLASHFOOT2 RAIL PV MODULE Last updated by andrea russell on 06/17/22 09:07 PM Page 3 of 6 5400 Main Street Northeast (#978659) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Splice Details INTERNAL SPLICE SIDE-FACING SLOT TOP-FACING SLOT XR100 XR100 RAIL BONDING SPRING XR100 INTERNAL SPLICE Splice Connection Clamp Detail Mid Clamp, Plan UNIVERSAL FASTENING OBJECT PV MODULE FRAME Mid Clamp, Front RAIL PV MODULEFRAME UNIVERSALFASTENINGOBJECT End Clamp, Plan STOPPERSLEEVE UNIVERSALFASTENINGOBJECT PV MODULEFRAME RAIL 1” End Clamp, Front PV MODULEFRAME RAIL UNIVERSALFASTENINGOBJECT STOPPERSLEEVE1” FlashFoot2 Detail Plan View 9” 12” 2 “316 Side View 1 “11 16 Perspective View Front View 1 “58 3 “516 “516 Last updated by andrea russell on 06/17/22 09:07 PM Page 4 of 6 5400 Main Street Northeast (#978659) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Grounding Diagram * Grounding Lugs and Wire are not required in systems using Enphase microinverters. UFO Clamp Fault Current Ground Path Min 10 AWG Copper Wire * Grounding Lug * Bonded Splice (Rail Connection) Last updated by andrea russell on 06/17/22 09:07 PM Page 5 of 6 5400 Main Street Northeast (#978659) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Bill of Materials Part Spares Total Qty Rails & Splices XR-100-204A XR100, Rail 204" (17 Feet) Clear 0 4 XR-100-168A XR100, Rail 168" (14 Feet) Clear 0 4 XR100-BOSS-01-M1 Bonded Splice, XR100 0 4 Clamps & Grounding UFO-CL-01-A1 Universal Module Clamp, Clear 0 40 UFO-STP-38MM-M1 Stopper Sleeve, 38MM, Mill 0 8 XR-LUG-03-A1 Grounding Lug, Low Profile 0 2 Attachments FF2-01-M2 FlashFoot2, Mill 0 32 BHW-SQ-02-A1 Square-Bolt Bonding Hardware 0 32 Last updated by andrea russell on 06/17/22 09:07 PM Page 6 of 6 5400 Main Street Northeast (#978659) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 © 2021 IronRidge, Inc.MN Flush Mount System Certification Letter - 1 28357 Industrial Blvd. Hayward, CA 94545 1-800-227-9523 IronRidge.com Attn: Corey Geiger, COO, IronRidge Inc. Date: August 31st, 2021 Re: Structural Certification and Span Tables for IronRidge Flush Mount System This letter addresses the structural performance and code compliance of IronRidge’s Flush Mount System. The contents of the letter shall be read in its entirety before being applied to any project design. The Flush Mount System is a proprietary rooftop mounting system used to support photovoltaic (PV) modules installed in portrait or landscape orientation and set parallel to the underlying roof surface. PV modules are supported by extruded aluminum XR Rails and secured to the rails with IronRidge mounting clamps. The XR Rails are side mounted to a selected roof attachment with 3/8” stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion that is fastened to the underlying roof structure. Assembly details of a typical Flush Mount installation and its core components are shown in Exhibit EX-0015. The IronRidge Flush Mount System is designed and certified to the structural requirements of the reference standards listed below, for the load conditions and configurations tabulated in the attached span tables. •ASCE/SEI 7-10 Minimum Design Loads for Buildings and Other Structures (ASCE 7-10) •2015 International Building Code (IBC-2015) •2015 Minnesota State Building Code •2015 Aluminum Design Manual (ADM-2015) The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for the respective loads and configurations listed, covering wind exposure categories B, C, & D, roof zones 1, 2 & 3, and roof slopes from 8º to 45º. The span tables are applicable provided that the following conditions are met: 1.Span is the distance between two adjacent roof attachment points (measured at the center of the attachment fastener) 2.The underlying roof slope, measured between roof surface and horizontal plane, is 8º to 45º. 3.Each module shall be supported by 2 rails (2 rail system) or 3 rails (3 rail system). Spans are calculated based on 2 rail systems, and conservatively deemed acceptable for 3 rail systems. 4. The mean roof height, defined as the average of the roof eave height and the roof ridge height measured from grade, does not exceed 30 feet. 5.Module length and area shall not exceed the maximum values listed on the respective span tables. 6.All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge’s Flush Mount installation manual and other applicable standards for general roof construction practice. © 2021 IronRidge, Inc. MN Flush Mount System Certification Letter - 2 28357 Industrial Blvd. Hayward, CA 94545 1-800-227-9523 IronRidge.com The parameters and adjustments allowed in the span tables are defined as the following: 1. The Flush Mount System is designed as a Risk Category II structure as defined by ASCE 7-10 Chart 1.5-1. 2. The wind speed selection shall conform to ASCE 7-10 Fig. 26.5-1A (Risk Category II wind) and any state & local county/city amendments to the IBC. No special wind topographic features are included in the span tables and the topographic coefficient (Kzt) is taken as 1.0. 3. The snow load used in the span tables is the ground snow and shall conform to ASCE 7-10 Fig. 7-1 and applicable state & local county/city amendments to the IBC. If the local jurisdiction specified snow load is in the format of a flat roof snow load, it shall first be converted to a ground snow following the local building code/amendment before the application of the attached span tables. No special snow conditions are considered including unbalanced, drifting, sliding, retention, or ponding snow. The span tables do not include buildings which are intentionally kept below freezing, kept just above freezing, or unheated. 4. The span tables reflect the ASCE 7 prescribed earthquake loads with the maximum magnitudes being: 1) For ground snow no greater than 42psf: Ss ≤ 2.0g for Site Class A, B, C, or D. 2) For ground snow greater than 65psf: Ss ≤ 1.0g for Site Class A, B, C, or D. 3) For ground snow between 42 and 65psf: Ss ≤ 1.5g for Site Class A, B, C, or D. 5. Roof zone size and definition conforms to ASCE 7-10 Fig. 30.4-2A to 30.4-2C. 6. Allowable span length in the charts may be multiplied by a factor of 1.08 if the rails are continuous over a minimum of three spans. 7. The maximum rail cantilever length, measured from the rail end to the nearest attachment point, shall be the lesser of the following two conditions: 40% of the allowable span provided for the respective load & configuration condition from the span tables, or 36”. 8. An array to roof clearance of 2” minimum must be provided. 9. No splices are allowed in the rail cantilever. For each XR splice type install per the following requirements: a) XR Bonded Splice cannot be installed in the center 1/3 of interior spans, or the outer 2/3 of end spans. b) BOSS Splice can be installed at any location within a span. 10. Shaded cells of the span tables indicate conditions in which UFO Mid Clamp connection capacity is exceeded. If such conditions are encountered contact support@ironridge.com. 11. When a roof attachment listed in IronRidge’s Flush Mount installation manual is considered, the span values provided in this letter can be adjusted using IronRidge’s online Design Assistant by checking the capacity of the selected roof attachment against the reaction forces provided in Design Assistant. © 2021 IronRidge, Inc. MN Flush Mount System Certification Letter - 3 28357 Industrial Blvd. Hayward, CA 94545 1-800-227-9523 IronRidge.com 12. Systems using CAMO module clamps shall be installed with the following guidance: 1) For single module installations (“orphan modules”) using modules with a length greater than 67.5”, CAMO clamps shall not be installed in regions that experience ground snow loads of 70psf and greater: such scenarios are shown by asterisks in the applicable span table. 2) CAMO will function within a module’s design load ratings. Be sure the specific module being used with CAMO meets the dimensional requirements shown in the figure below and that the module selected is suitable for the environmental conditions of a particular project. Figure 1: CAMO Module Frame Dimensional Requirements © 2021 IronRidge, Inc.MN Flush Mount System Certification Letter - 4 28357 Industrial Blvd. Hayward, CA 94545 1-800-227-9523IronRidge.com The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no consideration of the structural adequacy of the chosen roof attachments, PV modules, or the underlying roof supporting members. It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the aforementioned system components in regards to the applied or resultant loads of any chosen array configuration. Sincerely, Gang Xuan, PE Senior Structural Engineer Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 38‐27 129 116 96 105 105 96 89 89 89 87 87 87 81 81 81 74 74 74 68 68 68 64 64 64 59 59 59 56565653535351515149494928‐45 124 124 124 103 103 103 88 88 88 87 87 87 80 80 80 75 75 75 72 72 72 67 67 67 64 6464 60 60 60 57 57 57 55 55 55 53 53 538‐27 129 111 90 105 105 90 89 89 89 87 87 87 81 81 81 74 74 74 68 68 68 64 64 64 59 59 59 56565653535351515149494928‐45 121 121 121 103 103 103 88 88 88 87 87 87 80 80 80 75 75 75 72 72 72 67 67 67 64 6464 60 60 60 57 57 57 55 55 55 53 53 538‐27 129 107 86 105 105 86 89 89 86 87 87 86 81 81 81 74 74 74 68 68 68 64 64 64 59 59 59 56565653535351515149494928‐45 118 118 118 103 103 103 88 88 88 87 87 87 80 80 80 75 75 75 72 72 72 67 67 67 64 6464 60 60 60 57 57 57 55 55 55 53 53 538‐27 129 98 79 105 98 79 89 89 79 87 87 79 81 81 79 74 74 74 68 68 68 64 64 64 59 59 59 56 565653535351515149494928‐45 112 110 110 103 103 103 88 88 88 87 87 87 80 80 80 75 75 75 72 72 72 67 67 67 64 6464 60 60 60 57 57 57 55 55 55 53 53 538‐27 123 91 73 105 91 73 89 89 73 87 87 73 81 81 73 74 74 73 68 68 68 64 64 64 59 59 59 56 565653535351515149494928‐45 106 103 103 100 100 100 88 88 88 87 87 87 80 80 80 75 75 75 72 72 72 67 67 67 64 6464 60 60 60 57 57 57 55 55 55 53 53 538‐27 115 85 69 105 85 69 89 85 69 87 85 69 81 81 69 74 74 69 68 68 68 64 64 64 59 59 59 56 565653535351515149494928‐45 101 97 97 97 97 97 85 85 85 84 84 84 79 79 79 74 74 74 72 72 72 67 67 67 64 64 64 60 60605757575555555353538‐27 108 80 64 105 80 64 89 80 64 87 80 64 81 80 64 74 74 64 68 68 64 64 64 64 59 59 59 56 565653535351515149494928‐45 96 91 91 96 91 91 83 83 83 82 82 82 77 77 77 73 73 73 69 69 69 66 66 66 64 64 64 60 6060 57 57 57 55 55 55 53 53 538‐27 102 75 60 102 75 60 89 75 60 87 75 60 80 75 60 74 74 60 68 68 60 64 64 60 59 59 59 56 565653535351515149494928‐45 92 86 86 90 86 86 81 81 81 80 80 80 75 75 75 72 72 72 67 67 67 64 64 64 64 64 64 59 5959 57 57 57 55 55 55 53 53 538‐27 96 72 56 96 72 56 87 72 56 86 72 56 79 72 56 73 72 56 68 68 56 64 64 56 59 59 56 56 56 5653535351515149494928‐45 88 82 82 87 82 82 79 79 79 78 78 78 73 73 73 72 72 72 66 66 66 64 64 64 61 61 61 58 5858 56 56 56 55 55 55 53 53 53Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 38‐27 129 98 79 105 98 79 89 89 79 87 87 79 81 81 79 74 74 74 68 68 68 64 64 64 59 59 59 56 565653535351515149494928‐45 112 110 110 103 103 103 88 88 88 87 87 87 80 80 80 75 75 75 72 72 72 67 67 67 64 6464 60 60 60 57 57 57 55 55 55 53 53 538‐27 126 96 76 105 96 76 89 89 76 87 87 76 81 81 76 74 74 74 68 68 68 64 64 64 59 59 59 56 565653535351515149494928‐45 108 106 106 102 102 102 88 88 88 87 87 87 80 80 80 75 75 75 72 72 72 67 67 67 64 6464 60 60 60 57 57 57 55 55 55 53 53 538‐27 121 90 72 105 90 72 89 89 72 87 87 72 81 81 72 74 74 72 68 68 68 64 64 64 59 59 59 56 565653535351515149494928‐45 105 102 102 99 99 99 87 87 87 86 86 86 80 80 80 75 75 75 72 72 72 67 67 67 64 64 64 6060605757575555555353538‐27 112 83 67 105 83 67 89 83 67 87 83 67 81 81 67 74 74 67 68 68 67 64 64 64 59 59 59 56 565653535351515149494928‐45 99 96 96 96 96 96 85 85 85 84 84 84 78 78 78 73 73 73 72 72 72 66 66 66 64 64 64 60 6060 57 57 57 55 55 55 53 53 538‐27 104 77 64 104 77 64 89 77 64 87 77 64 81 77 64 74 74 64 68 68 64 64 64 64 59 59 59 56 565653535351515149494928‐45 96 88 88 92 88 88 82 82 82 81 81 81 76 76 76 72 72 72 68 68 68 65 65 65 64 64 64 60 6060 57 57 57 55 55 55 53 53 538‐27 98 72 58 98 72 58 88 72 58 87 72 58 79 72 58 74 72 58 68 68 58 64 64 58 59 59 58 56 56 5653535351515149494928‐45 89 83 83 88 83 83 79 79 79 79 79 79 74 74 74 72 72 72 67 67 67 64 64 64 61 61 61 59 5959 57 57 57 55 55 55 53 53 538‐27 92 67 50 92 67 50 86 67 50 85 67 50 78 67 50 73 67 50 68 67 50 64 64 50 59 59 50 56 56 5053535051515049494928‐45 84 78 78 84 78 78 77 77 77 76 76 76 72 72 72 68 68 68 65 65 65 64 64 64 60 60 60 58 5858 56 56 56 54 54 54 52 52 528‐27 86 64 44 86 64 44 84 64 44 83 64 44 77 64 44 72 64 44 67 64 44 64 64 44 59 59 44 56 56 4453534451514449494428‐45 80 73 73 80 73 73 74 73 73 74 73 73 72 72 72 66 66 66 64 64 64 61 61 61 59 59 59 57 5757 55 55 55 53 53 53 52 52 528‐27 82 60 40 82 60 40 82 60 40 81 60 40 75 60 40 72 60 40 66 60 40 64 60 40 59 59 40 56 56 4053534051514049494028‐45 76 72 72 76 72 72 72 72 72 72 72 72 68 68 68 65 65 65 64 64 64 60 60 60 57 57 57 56 5656 54 54 54 52 52 52 51 51 51Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 38‐27 122 90 73 105 90 73 89 89 73 87 87 73 81 81 73 74 74 73 68 68 72 64 64 64 60 60 60 56 565654545451515149494928‐45 105 102 102 100 100 100 87 87 87 87 87 87 80 80 80 75 75 75 72 72 72 68 68 68 64 6464 60 60 60 58 58 58 55 55 55 53 53 538‐27 116 86 72 105 86 72 89 86 72 87 86 72 81 81 72 74 74 72 68 68 68 64 64 64 60 60 60 56 565654545451515149494928‐45 102 98 98 97 97 97 86 86 86 86 86 86 80 80 80 75 75 75 72 72 72 67 67 67 64 64 64 60 60605858585555555353538‐27 112 83 67 105 83 67 89 83 67 87 83 67 81 81 67 74 74 67 68 68 67 64 64 64 60 60 60 56 565654545451515149494928‐45 99 96 96 96 96 96 84 84 84 84 84 84 79 79 79 74 74 74 72 72 72 67 67 67 64 64 64 60 6060 58 58 58 55 55 55 53 53 538‐27 103 76 64 103 76 64 89 76 64 87 76 64 81 76 64 74 74 64 68 68 64 64 64 64 60 60 60 56 565654545451515149494928‐45 96 87 87 91 87 87 82 82 82 81 81 81 76 76 76 72 72 72 68 68 68 65 65 65 64 64 64 60 6060 58 58 58 55 55 55 53 53 538‐27 96 72 56 96 72 56 87 72 56 87 72 56 80 72 56 74 72 56 68 68 56 64 64 56 60 60 56 56 56 5654545451515149494928‐45 88 82 82 87 82 82 79 79 79 79 79 79 74 74 74 72 72 72 67 67 67 64 64 64 61 61 61 59 5959 57 57 57 55 55 55 53 53 538‐27 90 66 48 90 66 48 85 66 48 85 66 48 78 66 48 73 66 48 68 66 48 64 64 48 60 60 48 56 56 4854544851514849494828‐45 83 76 76 83 76 76 76 76 76 76 76 76 72 72 72 68 68 68 65 65 65 64 64 64 60 60 60 58 5858 56 56 56 54 54 54 52 52 528‐27 84 64 42 84 64 42 83 64 42 83 64 42 76 64 42 72 64 42 67 64 42 64 64 42 60 60 42 56 56 4254544251514249494228‐45 78 72 72 78 72 72 73 72 72 73 72 72 72 72 72 66 66 66 64 64 64 61 61 61 58 58 58 56 5656 55 55 55 53 53 53 51 51 518‐27 79 58 37 79 58 37 79 58 37 79 58 37 75 58 37 72 58 37 66 58 37 64 58 37 60 58 37 56 56 3754543751513749493728‐45 74 68 68 74 68 68 72 68 68 72 68 68 67 67 67 64 64 64 64 64 64 59 59 59 57 57 57 55 5555 54 54 54 52 52 52 51 51 518‐27 75 52 33 75 52 33 75 52 33 75 52 33 73 52 33 69 52 33 65 52 33 64 52 33 59 52 33 56 52 3354523351513349493328‐45 72 64 64 72 64 64 68 64 64 68 64 64 65 64 64 64 64 64 60 60 60 58 58 58 56 56 56 54 5454 53 53 53 51 51 51 50 50 50= min 72" span = min 64" span = min 48" spanREV 03/05/2021 = Shaded cells indicate conditions in which UFO Mid Clamp connection capacity is exceeded.  See Note 10 on page 2 for details. 90 psfRail: XR100Flush Mount System Span Table (inches) ‐ Portrait or Landscape InstallationMax Module Length:  67.5", Max Module SF: 21 SF  Exposure BWind Speed (mph)Roof Slope  (deg.)Ground Snow: 0 psf10 psf 20 psf 30 psf 40 psf 50 psf120 psf100 psf 110 psf60 psf 70 psf140 mph150 mph160 mph170 mph180 mph80 psf110 mph115 mph120 mph130 mphRail: XR100Flush Mount System Span Table (inches) ‐ Portrait or Landscape InstallationMax Module Length:  67.5", Max Module SF: 21 SF  Exposure CWind Speed (mph)Roof Slope  (deg.)Ground Snow: 0 psf10 psf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf 90 psf 100 psf 110 psf 120 psf110 mph115 mph120 mph130 mph140 mph150 mph160 mph170 mph180 mphRail: XR100Flush Mount System Span Table (inches) ‐ Portrait or Landscape InstallationMax Module Length:  67.5", Max Module SF: 21 SF  Exposure DWind Speed (mph)Roof Slope  (deg.)Ground Snow: 0 psf10 psf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf 90 psf 100 psf 110 psf 120 psf110 mph115 mph120 mph130 mph140 mph150 mph160 mph170 mph180 mph Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 38‐27 121 109 87 100 100 87 84 84 84 83 83 83 76 76 76 72 72 72 64 64 64 59 59 59 55 55 55 52525250505048484848484828‐45 118 118 118 98 98 98 84 84 84 83 83 83 76 76 76 72 72 72 67 67 67 64 64 64 59 59 59 5656565353535151514949498‐27 121 104 83 100 100 83 84 84 83 83 83 83 76 76 76 72 72 72 64 64 64 59 59 59 55 55 55 52525250505048484848484828‐45 114 114 114 98 98 98 84 84 84 83 83 83 76 76 76 72 72 72 67 67 67 64 64 64 59 59 59 5656565353535151514949498‐27 121 100 80 100 100 80 84 84 80 83 83 80 76 76 76 72 72 72 64 64 64 59 59 59 55 55 55 52525250505048484848484828‐45 111 110 110 98 98 98 84 84 84 83 83 83 76 76 76 72 72 72 67 67 67 64 64 64 59 59 59 5656565353535151514949498‐27 118 92 74 100 92 74 84 84 74 83 83 74 76 76 74 72 72 72 64 64 64 59 59 59 55 55 55 52 525250505048484848484828‐45 105 103 103 97 97 97 84 84 84 83 83 83 76 76 76 72 72 72 67 67 67 64 64 64 59 59 59 5656565353535151514949498‐27 115 85 68 100 85 68 84 84 68 83 83 68 76 76 68 72 72 68 64 64 64 59 59 59 55 55 55 52 525250505048484848484828‐45 100 96 96 96 96 96 82 82 82 81 81 81 75 75 75 72 72 72 67 67 67 64 64 64 59 59 59 56 56565353535151514949498‐27 107 79 64 100 79 64 84 79 64 83 79 64 76 76 64 72 72 64 64 64 64 59 59 59 55 55 55 52 525250505048484848484828‐45 96 90 90 91 90 90 80 80 80 79 79 79 74 74 74 72 72 72 65 65 65 64 64 64 59 59 59 56 5656 53 53 53 51 51 51 49 49 498‐27 101 74 60 100 74 60 84 74 60 83 74 60 76 74 60 72 72 60 64 64 60 59 59 59 55 55 55 52 525250505048484848484828‐45 90 85 85 88 85 85 78 78 78 77 77 77 72 72 72 68 68 68 64 64 64 61 61 61 58 58 58 56 5656 53 53 53 51 51 51 49 49 498‐27 96 72 55 96 72 55 83 72 55 82 72 55 75 72 55 72 72 55 64 64 55 59 59 55 55 55 55 52 52 5250505048484848484828‐45 86 80 80 85 80 80 76 76 76 75 75 75 72 72 72 66 66 66 64 64 64 60 60 60 58 58 58 55 5555 53 53 53 51 51 51 49 49 498‐27 90 66 48 90 66 48 82 66 48 81 66 48 74 66 48 69 66 48 64 64 48 59 59 48 55 55 48 52 52 4850504848484848484828‐45 82 76 76 82 76 76 74 74 74 73 73 73 69 69 69 65 65 65 64 64 64 59 59 59 57 57 57 55 5555 53 53 53 51 51 51 49 49 49Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 38‐27 119 91 73 100 91 73 84 84 73 83 83 73 75 75 73 68 68 68 64 64 64 59 59 59 55 55 55 52 525249494948484848484828‐45 104 102 102 96 96 96 83 83 83 82 82 82 76 76 76 72 72 72 67 67 67 64 64 64 59 59 59 5656565353535151514949498‐27 117 87 72 100 87 72 84 84 72 83 83 72 75 75 72 68 68 68 64 64 64 59 59 59 55 55 55 52 525249494948484848484828‐45 101 98 98 96 96 96 82 82 82 81 81 81 75 75 75 72 72 72 67 67 67 64 64 64 59 59 59 56 56565353535151514949498‐27 113 84 67 100 84 67 84 84 67 83 83 67 75 75 67 68 68 67 64 64 64 59 59 59 55 55 55 52 525249494948484848484828‐45 98 96 96 92 92 92 81 81 81 80 80 80 74 74 74 72 72 72 66 66 66 64 64 64 59 59 59 56 5656 53 53 53 51 51 51 49 49 498‐27 104 77 64 100 77 64 84 77 64 83 77 64 75 75 64 68 68 64 64 64 64 59 59 59 55 55 55 52 525249494948484848484828‐45 92 88 88 89 88 88 78 78 78 78 78 78 72 72 72 68 68 68 64 64 64 64 64 64 59 59 59 56 5656 53 53 53 51 51 51 49 49 498‐27 97 72 58 97 72 58 83 72 58 82 72 58 75 72 58 68 68 58 64 64 58 59 59 58 55 55 55 52 52 5249494948484848484828‐45 87 82 82 85 82 82 76 76 76 75 75 75 72 72 72 66 66 66 64 64 64 60 60 60 58 58 58 55 5555 53 53 53 51 51 51 49 49 498‐27 91 67 50 91 67 50 81 67 50 80 67 50 74 67 50 68 67 50 64 64 50 59 59 50 55 55 50 52 52 5049494948484848484828‐45 82 77 77 82 77 77 74 74 74 73 73 73 68 68 68 65 65 65 64 64 64 59 59 59 57 57 57 54 5454 53 53 53 51 51 51 49 49 498‐27 85 64 43 85 64 43 80 64 43 79 64 43 72 64 43 67 64 43 64 64 43 59 59 43 55 55 43 52 52 4349494348484348484328‐45 78 72 72 78 72 72 72 72 72 72 72 72 67 67 67 64 64 64 60 60 60 58 58 58 55 55 55 53 5353 52 52 52 50 50 50 49 49 498‐27 80 59 38 80 59 38 78 59 38 77 59 38 72 59 38 66 59 38 64 59 38 59 59 38 55 55 38 52 52 3849493848483848483828‐45 74 68 68 74 68 68 69 68 68 68 68 68 65 65 65 64 64 64 59 59 59 56 56 56 54 54 54 52 5252 51 51 51 49 49 49 48 48 488‐27 76 53 34 76 53 34 76 53 34 75 53 34 72 53 34 65 53 34 64 53 34 58 53 34 55 53 34 52 52 3449493448483448483428‐45 72 65 65 72 65 65 67 65 65 66 65 65 64 64 64 60 60 60 57 57 57 55 55 55 53 53 53 51 5151 50 50 50 48 48 48 48 48 48Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 38‐27 113 84 67 100 84 67 84 84 67 83 83 67 76 76 67 72 72 67 64 64 64 59 59 59 55 55 55 52 525250505048484848484828‐45 98 96 96 92 92 92 81 81 81 81 81 81 75 75 75 72 72 72 66 66 66 64 64 64 59 59 59 56 5656 53 53 53 51 51 51 49 49 498‐27 108 80 64 100 80 64 84 80 64 83 80 64 76 76 64 72 72 64 64 64 64 59 59 59 55 55 55 52 525250505048484848484828‐45 96 91 91 90 90 90 80 80 80 79 79 79 74 74 74 72 72 72 66 66 66 64 64 64 59 59 59 56 5656 53 53 53 51 51 51 49 49 498‐27 104 77 64 100 77 64 84 77 64 83 77 64 76 76 64 72 72 64 64 64 64 59 59 59 55 55 55 52 525250505048484848484828‐45 92 87 87 88 87 87 78 78 78 78 78 78 73 73 73 68 68 68 65 65 65 64 64 64 59 59 59 56 5656 53 53 53 51 51 51 49 49 498‐27 96 72 57 96 72 57 83 72 57 82 72 57 75 72 57 72 72 57 64 64 57 59 59 57 55 55 55 52 52 5250505048484848484828‐45 86 81 81 85 81 81 76 76 76 75 75 75 72 72 72 67 67 67 64 64 64 60 60 60 58 58 58 56 5656 53 53 53 51 51 51 49 49 498‐27 89 66 48 89 66 48 81 66 48 81 66 48 74 66 48 72 66 48 64 64 48 59 59 48 55 55 48 52 52 4850504848484848484828‐45 81 76 76 81 76 76 73 73 73 73 73 73 72 72 72 65 65 65 64 64 64 59 59 59 57 57 57 54 5454 53 53 53 51 51 51 49 49 498‐27 83 61 42 83 61 42 79 61 42 79 61 42 72 61 42 67 61 42 64 61 42 59 59 42 55 55 42 52 52 4250504248484248484228‐45 77 72 72 77 72 72 72 72 72 72 72 72 66 66 66 64 64 64 60 60 60 58 58 58 55 55 55 53 5353 52 52 52 50 50 50 49 49 498‐27 78 57 36 78 57 36 77 57 36 77 57 36 72 57 36 66 57 36 64 57 36 59 57 36 55 55 36 52 52 3650503648483648483628‐45 73 67 67 73 67 67 68 67 67 68 67 67 64 64 64 61 61 61 59 59 59 56 56 56 54 54 54 52 5252 51 51 51 49 49 49 48 48 488‐27 74 50 32 74 50 32 74 50 32 74 50 32 72 50 32 65 50 32 61 50 32 58 50 32 55 50 32 52 50 3250503248483248483228‐45 72 64 64 72 64 64 66 64 64 66 64 64 64 64 64 60 60 60 57 57 57 55 55 55 53 53 53 51 5151 50 50 50 48 48 48 48 48 488‐27 72 44 29 72 44 29 72 44 29 72 44 29 68 44 29 64 44 29 60 44 29 57 44 29 55 44 29 52 44 2950442948442948442928‐45 65 59 59 65 59 59 64 59 59 64 59 59 60 59 59 58 58 58 56 56 56 54 54 54 52 52 52 50 5050 49 49 49 48 48 48 48 48 48= min 72" span = min 64" span = min 48" span* = Note: additional installation requirement for CAMO module clamp.  See Note 12 on Page 3 for details. REV 03/05/2021 = Shaded cells indicate conditions in which UFO Mid Clamp connection capacity is exceeded.  See Note 10 on page 2 for details. 140 mph150 mph160 mph170 mph180 mph120 psf*110 mph115 mph120 mph130 mphRail: XR100Flush Mount System Span Table (inches) ‐ Portrait or Landscape InstallationMax Module Length:  78.5", Max Module SF: 24 SF  Exposure DWind Speed (mph)Roof Slope  (deg.)Ground Snow: 0 psf10 psf 20 psf 30 psf 40 psf 50 psf60 psf 70 psf* 80 psf* 90 psf* 100 psf* 110 psf*140 mph150 mph160 mph170 mph180 mph120 psf*110 mph115 mph120 mph130 mphRail: XR100Flush Mount System Span Table (inches) ‐ Portrait or Landscape InstallationMax Module Length:  78.5", Max Module SF: 24 SF  Exposure CWind Speed (mph)Roof Slope  (deg.)Ground Snow: 0 psf10 psf 20 psf 30 psf 40 psf 50 psf60 psf 70 psf* 80 psf* 90 psf* 100 psf* 110 psf*90 psf*Rail: XR100Flush Mount System Span Table (inches) ‐ Portrait or Landscape InstallationMax Module Length:  78.5", Max Module SF: 24 SF  Exposure BWind Speed (mph)Roof Slope  (deg.)Ground Snow: 0 psf10 psf 20 psf 30 psf 40 psf 50 psf120 psf*100 psf* 110 psf*60 psf 70 psf* 80 psf*110 mph115 mph120 mph180 mph130 mph140 mph150 mph160 mph170 mph Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 38‐27 114 104 83 97 97 83 82 82 82 80 80 80 72 72 72 65 65 65 60 60 60 56 56 56 53 53 53 50 505048484845454543434328‐45 110 110 110 96 96 96 81 81 81 80 80 80 74 74 74 72 72 72 64 64 64 60 60 60 56 56 56 5353535151514848484848488‐27 114 99 80 97 97 80 82 82 80 80 80 80 72 72 72 65 65 65 60 60 60 56 56 56 53 53 53 50 5050 48 48 48 45 45 45 43 43 4328‐45 107 107 107 96 96 96 81 81 81 80 80 80 74 74 74 72 72 72 64 64 64 60 60 60 56 56 56 5353535151514848484848488‐27 114 96 76 97 96 76 82 82 76 80 80 76 72 72 72 65 65 65 60 60 60 56 56 56 53 53 53 50 5050 48 48 48 45 45 45 43 43 4328‐45 105 105 105 96 96 96 81 81 81 80 80 80 74 74 74 72 72 72 64 64 64 60 60 60 56 56 56 5353535151514848484848488‐27 114 88 72 97 88 72 82 82 72 80 80 72 72 72 72 65 65 65 60 60 60 56 56 56 53 53 53 50 5050 48 48 48 45 45 45 43 43 4328‐45 99 98 98 92 92 92 80 80 80 79 79 79 73 73 73 68 68 68 64 64 64 60 60 60 56 56 56 53 5353 51 51 51 48 48 48 48 48 488‐27 109 81 65 97 81 65 82 81 65 80 80 65 72 72 65 65 65 65 60 60 60 56 56 56 53 53 53 50 5050 48 48 48 45 45 45 43 43 4328‐45 96 91 91 89 89 89 78 78 78 77 77 77 72 72 72 67 67 67 64 64 64 60 60 60 56 56 56 53 5353 51 51 51 48 48 48 48 48 488‐27 102 76 61 97 76 61 82 76 61 80 76 61 72 72 61 65 65 61 60 60 60 56 56 56 53 53 53 50 5050 48 48 48 45 45 45 43 43 4328‐45 90 86 86 86 86 86 76 76 76 75 75 75 72 72 72 66 66 66 64 64 64 59 59 59 56 56 56 53 5353 51 51 51 48 48 48 48 48 488‐27 96 72 57 96 72 57 80 72 57 79 72 57 72 72 57 65 65 57 60 60 57 56 56 56 53 53 53 50 50 5048484845454543434328‐45 85 81 81 83 81 81 74 74 74 73 73 73 68 68 68 64 64 64 61 61 61 58 58 58 56 56 56 53 5353 51 51 51 48 48 48 48 48 488‐27 90 67 50 90 67 50 79 67 50 78 67 50 72 67 50 65 65 50 60 60 50 56 56 50 53 53 50 50 50 5048484845454543434328‐45 81 76 76 80 76 76 72 72 72 72 72 72 67 67 67 64 64 64 60 60 60 57 57 57 55 55 55 53 5353 51 51 51 48 48 48 48 48 488‐27 85 64 44 85 64 44 77 64 44 76 64 44 72 64 44 65 64 44 60 60 44 56 56 44 53 53 44 50 50 4448484445454443434328‐45 78 72 72 77 72 72 72 72 72 72 72 72 65 65 65 64 64 64 59 59 59 56 56 56 54 54 54 52 5252 50 50 50 48 48 48 48 48 48Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 38‐27 114 87 72 97 87 72 82 82 72 80 80 72 72 72 72 65 65 65 60 60 60 56 56 56 53 53 53 50 5050 48 48 48 45 45 45 43 43 4328‐45 99 98 98 92 92 92 80 80 80 79 79 79 73 73 73 68 68 68 64 64 64 60 60 60 56 56 56 53 5353 51 51 51 48 48 48 48 48 488‐27 112 84 67 97 84 67 82 82 67 80 80 67 72 72 67 65 65 65 60 60 60 56 56 56 53 53 53 50 5050 48 48 48 45 45 45 43 43 4328‐45 96 96 96 90 90 90 78 78 78 78 78 78 72 72 72 67 67 67 64 64 64 60 60 60 56 56 56 53 5353 51 51 51 48 48 48 48 48 488‐27 108 80 64 97 80 64 82 80 64 80 80 64 72 72 64 65 65 64 60 60 60 56 56 56 53 53 53 50 5050 48 48 48 45 45 45 43 43 4328‐45 96 90 90 88 88 88 77 77 77 76 76 76 72 72 72 67 67 67 64 64 64 60 60 60 56 56 56 53 5353 51 51 51 48 48 48 48 48 488‐27 100 74 59 97 74 59 81 74 59 80 74 59 72 72 59 65 65 59 60 60 59 56 56 56 53 53 53 50 5050 48 48 48 45 45 45 43 43 4328‐45 88 84 84 85 84 84 75 75 75 74 74 74 72 72 72 65 65 65 64 64 64 59 59 59 56 56 56 53 5353 51 51 51 48 48 48 48 48 488‐27 93 68 53 93 68 53 79 68 53 78 68 53 72 68 53 65 65 53 60 60 53 56 56 53 53 53 53 50 50 5048484845454543434328‐45 83 78 78 81 78 78 73 73 73 72 72 72 67 67 67 64 64 64 60 60 60 57 57 57 55 55 55 53 5353 51 51 51 48 48 48 48 48 488‐27 87 64 45 87 64 45 78 64 45 77 64 45 72 64 45 65 64 45 60 60 45 56 56 45 53 53 45 50 50 4548484545454543434328‐45 79 73 73 78 73 73 72 72 72 72 72 72 65 65 65 64 64 64 59 59 59 56 56 56 54 54 54 52 5252 50 50 50 48 48 48 48 48 488‐27 81 60 40 81 60 40 76 60 40 75 60 40 72 60 40 64 60 40 60 60 40 56 56 40 53 53 40 50 50 4048484045454043434028‐45 75 69 69 75 69 69 68 68 68 67 67 67 64 64 64 60 60 60 58 58 58 55 55 55 53 53 53 51 5151 49 49 49 48 48 48 48 48 488‐27 77 55 35 77 55 35 74 55 35 74 55 35 68 55 35 64 55 35 60 55 35 56 55 35 53 53 35 50 50 3548483545453543433528‐45 72 65 65 72 65 65 66 65 65 65 65 65 64 64 64 59 59 59 56 56 56 54 54 54 52 52 52 50 5050 48 48 48 48 48 48 48 48 488‐27 72 49 32 72 49 32 72 49 32 72 49 32 67 49 32 64 49 32 59 49 32 56 49 32 53 49 32 50 49 3248483245453243433228‐45 67 64 64 67 64 64 64 64 64 64 64 64 60 60 60 57 57 57 55 55 55 53 53 53 51 51 51 49 4949 48 48 48 48 48 48 45 45 45Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 38‐27 108 80 64 97 80 64 82 80 64 81 80 64 73 73 64 66 66 64 60 60 60 56 56 56 53 53 53 50 5050 48 48 48 45 45 45 44 44 4428‐45 96 90 90 88 88 88 77 77 77 77 77 77 72 72 72 67 67 67 64 64 64 60 60 60 57 57 57 54 5454 51 51 51 49 49 49 48 48 488‐27 103 77 64 97 77 64 82 77 64 81 77 64 73 73 64 66 66 64 60 60 60 56 56 56 53 53 53 50 5050 48 48 48 45 45 45 44 44 4428‐45 90 87 87 86 86 86 76 76 76 76 76 76 72 72 72 66 66 66 64 64 64 60 60 60 57 57 57 54 5454 51 51 51 49 49 49 48 48 488‐27 99 74 59 97 74 59 81 74 59 80 74 59 73 73 59 66 66 59 60 60 59 56 56 56 53 53 53 50 50 5048484845454544444428‐45 88 84 84 84 84 84 75 75 75 75 75 75 72 72 72 65 65 65 64 64 64 59 59 59 56 56 56 54 5454 51 51 51 49 49 49 48 48 488‐27 92 68 52 92 68 52 79 68 52 79 68 52 72 68 52 66 66 52 60 60 52 56 56 52 53 53 52 50 50 5048484845454544444428‐45 82 78 78 81 78 78 72 72 72 72 72 72 67 67 67 64 64 64 60 60 60 58 58 58 55 55 55 53 5353 51 51 51 49 49 49 48 48 488‐27 85 64 44 85 64 44 77 64 44 77 64 44 72 64 44 66 64 44 60 60 44 56 56 44 53 53 44 50 50 4448484445454444444428‐45 78 72 72 77 72 72 72 72 72 72 72 72 65 65 65 64 64 64 59 59 59 56 56 56 54 54 54 52 5252 50 50 50 49 49 49 48 48 488‐27 80 59 38 80 59 38 76 59 38 75 59 38 69 59 38 64 59 38 60 59 38 56 56 38 53 53 38 50 50 3848483845453844443828‐45 73 68 68 73 68 68 67 67 67 67 67 67 64 64 64 60 60 60 57 57 57 55 55 55 53 53 53 51 5151 49 49 49 48 48 48 48 48 488‐27 75 52 33 75 52 33 74 52 33 73 52 33 68 52 33 64 52 33 60 52 33 56 52 33 53 52 33 50 50 3348483345453344443328‐45 72 64 64 72 64 64 65 64 64 65 64 64 64 64 64 59 59 59 56 56 56 54 54 54 52 52 52 50 5050 48 48 48 48 48 48 48 48 488‐27 72 48 29 72 48 29 72 48 29 72 48 29 66 48 29 64 48 29 59 48 29 56 48 29 53 48 29 50 48 2948482945452944442928‐45 66 60 60 66 60 60 64 60 60 64 60 60 60 60 60 57 57 57 55 55 55 52 52 52 51 51 51 49 4949 48 48 48 48 48 48 45 45 458‐27 67 41 26 67 41 26 67 41 26 67 41 26 65 41 26 61 41 26 58 41 26 55 41 26 52 41 26 50 41 2648412645412644412628‐45 64 57 57 64 57 57 61 57 57 61 57 57 58 57 57 55 55 55 53 53 53 51 51 51 49 49 49 48 4848 48 48 48 45 45 45 44 44 44= min 72" span = min 64" span = min 48" span* = Note: additional installation requirement for CAMO module clamp.  See Note 12 on Page 3 for details. REV 03/05/2021 = Shaded cells indicate conditions in which UFO Mid Clamp connection capacity is exceeded.  See Note 10 on page 2 for details. 140 mph150 mph160 mph170 mph180 mph120 psf*110 mph115 mph120 mph130 mphRail: XR100Flush Mount System Span Table (inches) ‐ Portrait or Landscape InstallationMax Module Length:  86", Max Module SF: 24.5 SF  Exposure DWind Speed (mph)Roof Slope  (deg.)Ground Snow: 0 psf10 psf 20 psf 30 psf 40 psf 50 psf60 psf 70 psf* 80 psf* 90 psf* 100 psf* 110 psf*140 mph150 mph160 mph170 mph180 mph120 psf*110 mph115 mph120 mph130 mphRail: XR100Flush Mount System Span Table (inches) ‐ Portrait or Landscape InstallationMax Module Length:  86", Max Module SF: 24.5 SF  Exposure CWind Speed (mph)Roof Slope  (deg.)Ground Snow: 0 psf10 psf 20 psf 30 psf 40 psf 50 psf60 psf 70 psf* 80 psf* 90 psf* 100 psf* 110 psf*80 psf*110 mph115 mph120 mph130 mph140 mph150 mph160 mph170 mph180 mph90 psf*Rail: XR100Flush Mount System Span Table (inches) ‐ Portrait or Landscape InstallationMax Module Length:  86", Max Module SF: 24.5 SF  Exposure BWind Speed (mph)Roof Slope  (deg.)Ground Snow: 0 psf10 psf 20 psf 30 psf 40 psf 50 psf120 psf*100 psf* 110 psf*60 psf 70 psf* Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 38‐27 110 100 80 96 96 80 79 79 79 77 77 77 72 72 72 64 64 64 58 58 58 54 54 54 51 51 51 48 484848484844444442424228‐45 106 106 106 93 93 93 79 79 79 78 78 78 72 72 72 66 66 66 64 64 64 58 58 58 54 54 54 5151514949494848484545458‐27 110 96 77 96 96 77 79 79 77 77 77 77 72 72 72 64 64 64 58 58 58 54 54 54 51 51 51 48 4848 48 48 48 44 44 44 42 42 4228‐45 104 104 104 93 93 93 79 79 79 78 78 78 72 72 72 66 66 66 64 64 64 58 58 58 54 54 54 5151514949494848484545458‐27 110 92 74 96 92 74 79 79 74 77 77 74 72 72 72 64 64 64 58 58 58 54 54 54 51 51 51 48 4848 48 48 48 44 44 44 42 42 4228‐45 101 101 101 92 92 92 79 79 79 78 78 78 72 72 72 66 66 66 64 64 64 58 58 58 54 54 54 5151514949494848484545458‐27 110 85 68 96 85 68 79 79 68 77 77 68 72 72 68 64 64 64 58 58 58 54 54 54 51 51 51 48 4848 48 48 48 44 44 44 42 42 4228‐45 96 96 96 89 89 89 77 77 77 76 76 76 72 72 72 66 66 66 64 64 64 58 58 58 54 54 54 51 5151 49 49 49 48 48 48 45 45 458‐27 105 78 64 96 78 64 79 78 64 77 77 64 72 72 64 64 64 64 58 58 58 54 54 54 51 51 51 48 4848 48 48 48 44 44 44 42 42 4228‐45 91 88 88 86 86 86 75 75 75 74 74 74 69 69 69 64 64 64 61 61 61 58 58 58 54 54 54 51 5151 49 49 49 48 48 48 45 45 458‐27 98 73 59 96 73 59 79 73 59 77 73 59 72 72 59 64 64 59 58 58 58 54 54 54 51 51 51 48 48 4848484844444442424228‐45 86 83 83 83 83 83 73 73 73 72 72 72 67 67 67 64 64 64 60 60 60 57 57 57 54 54 54 51 5151 49 49 49 48 48 48 45 45 458‐27 92 68 53 92 68 53 77 68 53 76 68 53 72 68 53 64 64 53 58 58 53 54 54 53 51 51 51 48 48 4848484844444442424228‐45 82 78 78 80 78 78 72 72 72 72 72 72 66 66 66 64 64 64 59 59 59 56 56 56 54 54 54 51 5151 49 49 49 48 48 48 45 45 458‐27 87 64 48 87 64 48 76 64 48 75 64 48 69 64 48 64 64 48 58 58 48 54 54 48 51 51 48 48 48 4848484844444442424228‐45 78 74 74 77 74 74 72 72 72 68 68 68 64 64 64 61 61 61 58 58 58 55 55 55 53 53 53 51 5151 49 49 49 48 48 48 45 45 458‐27 82 61 41 82 61 41 75 61 41 74 61 41 68 61 41 64 61 41 58 58 41 54 54 41 51 51 41 48 48 4148484144444142424128‐45 75 72 72 75 72 72 67 67 67 67 67 67 64 64 64 59 59 59 57 57 57 54 54 54 52 52 52 50 5050 48 48 48 48 48 48 45 45 45Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 38‐27 110 84 68 96 84 68 79 79 68 77 77 68 72 72 68 64 64 64 58 58 58 54 54 54 51 51 51 48 4848 48 48 48 44 44 44 42 42 4228‐45 96 96 96 89 89 89 77 77 77 76 76 76 72 72 72 66 66 66 64 64 64 58 58 58 54 54 54 51 5151 49 49 49 48 48 48 45 45 458‐27 108 81 65 96 81 65 79 79 65 77 77 65 72 72 65 64 64 64 58 58 58 54 54 54 51 51 51 48 4848 48 48 48 44 44 44 42 42 4228‐45 96 90 90 87 87 87 76 76 76 75 75 75 72 72 72 65 65 65 64 64 64 58 58 58 54 54 54 51 5151 49 49 49 48 48 48 45 45 458‐27 104 77 64 96 77 64 79 77 64 77 77 64 72 72 64 64 64 64 58 58 58 54 54 54 51 51 51 48 4848 48 48 48 44 44 44 42 42 4228‐45 90 87 87 85 85 85 75 75 75 74 74 74 68 68 68 64 64 64 61 61 61 58 58 58 54 54 54 51 5151 49 49 49 48 48 48 45 45 458‐27 96 72 57 96 72 57 78 72 57 77 72 57 72 72 57 64 64 57 58 58 57 54 54 54 51 51 51 48 48 4848484844444442424228‐45 85 81 81 82 81 81 72 72 72 72 72 72 67 67 67 64 64 64 59 59 59 57 57 57 54 54 54 51 5151 49 49 49 48 48 48 45 45 458‐27 89 66 49 89 66 49 77 66 49 76 66 49 72 66 49 64 64 49 58 58 49 54 54 49 51 51 49 48 48 4848484844444442424228‐45 80 76 76 78 76 76 72 72 72 72 72 72 65 65 65 64 64 64 58 58 58 55 55 55 53 53 53 51 5151 49 49 49 48 48 48 45 45 458‐27 84 64 42 84 64 42 75 64 42 74 64 42 68 64 42 64 64 42 58 58 42 54 54 42 51 51 42 48 48 4248484244444242424228‐45 76 72 72 75 72 72 68 68 68 67 67 67 64 64 64 60 60 60 57 57 57 54 54 54 52 52 52 50 5050 48 48 48 48 48 48 45 45 458‐27 78 58 37 78 58 37 73 58 37 72 58 37 67 58 37 64 58 37 58 58 37 54 54 37 51 51 37 48 48 3748483744443742423728‐45 72 67 67 72 67 67 66 66 66 65 65 65 64 64 64 58 58 58 55 55 55 53 53 53 51 51 51 49 4949 48 48 48 48 48 48 45 45 458‐27 74 51 32 74 51 32 72 51 32 72 51 32 65 51 32 61 51 32 57 51 32 54 51 32 51 51 32 48 48 3248483244443242423228‐45 68 64 64 68 64 64 64 64 64 64 64 64 60 60 60 57 57 57 54 54 54 52 52 52 50 50 50 48 4848 48 48 48 48 48 48 44 44 448‐27 72 45 29 72 45 29 72 45 29 72 45 29 64 45 29 60 45 29 57 45 29 54 45 29 51 45 29 48 45 2948452944442942422928‐45 65 60 60 65 60 60 64 60 60 61 60 60 58 58 58 55 55 55 53 53 53 51 51 51 49 49 49 48 4848 48 48 48 45 45 45 43 43 43Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 38‐27 104 78 64 96 78 64 79 78 64 78 78 64 72 72 64 64 64 64 58 58 58 54 54 54 51 51 51 48 4848 48 48 48 44 44 44 42 42 4228‐45 90 87 87 85 85 85 75 75 75 74 74 74 69 69 69 65 65 65 61 61 61 58 58 58 54 54 54 52 5252 49 49 49 48 48 48 45 45 458‐27 100 74 59 96 74 59 79 74 59 78 74 59 72 72 59 64 64 59 58 58 58 54 54 54 51 51 51 48 4848 48 48 48 44 44 44 42 42 4228‐45 87 84 84 83 83 83 73 73 73 73 73 73 68 68 68 64 64 64 60 60 60 57 57 57 54 54 54 52 5252 49 49 49 48 48 48 45 45 458‐27 96 72 57 96 72 57 78 72 57 78 72 57 72 72 57 64 64 57 58 58 57 54 54 54 51 51 51 48 48 4848484844444442424228‐45 84 81 81 81 81 81 72 72 72 72 72 72 67 67 67 64 64 64 60 60 60 57 57 57 54 54 54 52 5252 49 49 49 48 48 48 45 45 458‐27 89 65 48 89 65 48 76 65 48 76 65 48 69 65 48 64 64 48 58 58 48 54 54 48 51 51 48 48 48 4848484844444442424228‐45 79 75 75 78 75 75 72 72 72 72 72 72 65 65 65 61 61 61 58 58 58 56 56 56 53 53 53 51 5151 49 49 49 48 48 48 45 45 458‐27 82 61 41 82 61 41 75 61 41 74 61 41 68 61 41 64 61 41 58 58 41 54 54 41 51 51 41 48 48 4148484144444142424128‐45 75 72 72 75 72 72 67 67 67 67 67 67 64 64 64 60 60 60 57 57 57 54 54 54 52 52 52 50 5050 48 48 48 48 48 48 45 45 458‐27 77 56 35 77 56 35 73 56 35 73 56 35 67 56 35 64 56 35 58 56 35 54 54 35 51 51 35 48 48 3548483544443542423528‐45 72 65 65 72 65 65 65 65 65 65 65 65 61 61 61 58 58 58 55 55 55 53 53 53 51 51 51 49 4949 48 48 48 48 48 48 45 45 458‐27 72 49 32 72 49 32 72 49 32 72 49 32 65 49 32 61 49 32 57 49 32 54 49 32 51 49 32 48 48 3248483244443242423228‐45 67 64 64 67 64 64 64 64 64 64 64 64 59 59 59 56 56 56 54 54 54 52 52 52 50 50 50 48 4848 48 48 48 45 45 45 44 44 448‐27 68 43 27 68 43 27 68 43 27 68 43 27 64 43 27 60 43 27 57 43 27 54 43 27 51 43 27 48 43 2748432744432742422728‐45 64 58 58 64 58 58 61 58 58 60 58 58 57 57 57 55 55 55 53 53 53 51 51 51 49 49 49 48 4848 48 48 48 44 44 44 43 43 438‐27 64 38 24 64 38 24 64 38 24 64 38 24 64 38 24 59 38 24 56 38 24 53 38 24 50 38 24 48 38 2448382444382442382428‐45 60 54 54 60 54 54 58 54 54 58 54 54 56 54 54 53 53 53 51 51 51 49 49 49 48 48 48 48 4848 45 45 45 44 44 44 42 42 42= min 72" span = min 64" span = min 48" span* = Note: additional installation requirement for CAMO module clamp.  See Note 12 on Page 3 for details. REV 03/05/2021 = Shaded cells indicate conditions in which UFO Mid Clamp connection capacity is exceeded.  See Note 10 on page 2 for details. 140 mph150 mph160 mph170 mph180 mph120 psf*110 mph115 mph120 mph130 mphRail: XR100Flush Mount System Span Table (inches) ‐ Portrait or Landscape InstallationMax Module Length:  92.5", Max Module SF: 29.5 SF  Exposure DWind Speed (mph)Roof Slope  (deg.)Ground Snow: 0 psf10 psf20 psf30 psf40 psf50 psf60 psf70 psf* 80 psf* 90 psf* 100 psf* 110 psf*140 mph150 mph160 mph170 mph180 mph120 psf*110 mph115 mph120 mph130 mphRail: XR100Flush Mount System Span Table (inches) ‐ Portrait or Landscape InstallationMax Module Length:  92.5", Max Module SF: 29.5 SF  Exposure CWind Speed Roof Slope  Ground Snow: 0 psf10 psf20 psf30 psf40 psf50 psf60 psf70 psf* 80 psf* 90 psf* 100 psf* 110 psf*80 psf*110 mph115 mph120 mph130 mph140 mph150 mph160 mph170 mph180 mph90 psf*Rail: XR100Flush Mount System Span Table (inches) ‐ Portrait or Landscape InstallationMax Module Length:  92.5", Max Module SF: 29.5 SF  Exposure BWind Speed (mph)Roof Slope  (deg.)Ground Snow: 0 psf10 psf20 psf30 psf40 psf50 psf120 psf*100 psf* 110 psf*60 psf70 psf* VARIES VARIES VARIES VARIES C B A XR RAIL(OPTIONAL 3RD RAIL) PLAN VIEW DETAIL C(MODULE GLASS REMOVED FOR CLARITY) MODULE MOUNTING SYSTEMBONDING END CLAMP, CAMO XR RAIL PV MODULE DETAIL B(MODULE GLASS REMOVED FOR CLARITY) MODULE MOUNTING SYSTEM BONDING MID CLAMP, UFO XR RAIL PV MODULE SLOPE DETAIL A MODULE MOUNTING SYSTEMBONDING END CLAMP, UFO XR RAIL PV MODULE EXHIBIT: EX-0015 - page 1 of 2 06/01/2021 FLUSH MOUNT SYSTEM PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF IRONRIDGE INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF IRONRIDGE INC. IS PROHIBITED. SHEET 1 OF 2 DWG. NO.EX-0015 WEIGHT: N/A SIZE-- SCALE: NTS 0.4 X L (MAX) (L) SPAN (L) SPAN 0.4 X L (MAX) GFED EXISTING ROOF STRUCTURE DETAIL G MODULE MOUNTING SYSTEMBONDING END CLAMP, UFO XR RAIL PV MODULE DETAIL F PV MODULE XR RAIL OPTIONS, TYP: ROOF FRAMING(BY OTHERS) ROOF COVERING(BY OTHERS) 3/8" BOLT ANDNUT, (TYP) ROOF ATTACHMENT(FLASHFOOT2 SHOWN FOR REFERENCE) 3/8" MODULE GAP (TYP) DETAIL E PV MODULE XR RAIL MODULE MOUNTING SYSTEMBONDING MID CLAMP, UFO DETAIL D(MODULE REMOVED FOR CLARITY) MODULE MOUNTING SYSTEMBONDING END CLAMP, CAMOXR RAIL 1.75" 2.44" 3.0" XR 10EXHIBIT: EX-0015 - page 2 of 2 06/01/2021 PLAN VIEW XR 100 XR1000 FLUSH MOUNT SYSTEM PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF IRONRIDGE INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF IRONRIDGE INC. IS PROHIBITED. WEIGHT: N/A SHEET 2 OF 2 --DWG. NO.SIZE SCALE: NTS EX-0015 8431 Murphy Drive Middleton, WI 53562 USA Telephone: 608.836.4400 Facsimile: 608.831.9279 www.intertek.com Test Verification of Conformity This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. GFT-OP-11a (24-MAR-2014) Signature: Name: Nalini Mandadi Position: Project Engineer Date: 11/14/2014 In the basis of the tests undertaken, the sample(s) of the below product have been found to comply with the requirements of the referenced specifications at the time the tests were carried out. Applicant Name & Address: IronRidge, Inc. 28357 Industrial Blvd Hayward, CA 94545 USA Product Description: Flush Mount System with XR Rails. Ratings & Principle Characteristics: Fire Class Resistance Rating: -Flush Mount (Symmetrical). Class A Fire Rated for Low Slope applications when using Type 1, 2, 3, 13, 19, 25 and 29 listed photovoltaic modules. Class A Fire Rated for Steep Slope applications with Type1, 2 and 3, listed photovoltaic modules. Tested with a 5” gap (distance between the bottom the module frame and the roof covering), per the standard this system can be installed at any gap allowed by the manufacturers installation instructions. No perimeter guarding is required. This rating is applicable with any IronRidge or 3’rd party roof anchor. Models: IronRidge Flush Mount with XR Rails Brand Name: IronRidge Flush Mount Relevant Standards: UL 2703 (Section 15.2 and 15.3) Standard for Safety Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels, First Edition dated Jan. 28, 2015 Referencing UL1703 Third Edition dated Nov. 18, 2014, (Section 31.2) Standard for Safety for Flat-Plate Photovoltaic Modules and Panels. Verification Issuing Office: Intertek Testing Services NA, Inc. 8431 Murphy Drive Middleton, WI 53562 Date of Tests: 08/27/2014 to 03/17/2015 Test Report Number(s): 101769343MID-001r1, 101769343MID-001a, 101915978MID-001 & 101999492MID-001ar1-cr1, 104428358MID-001 EEV Revision Summary 8/27/2020 Added type 13, 19, 25 and 29 to system, update address. This verification is part of the full test report(s) and should be read in conjunction with them. This report does not automatically imply product certification. Completed by: Chris Zimbrich Reviewed by: Chad Naggs Title: Technician I, Fire Resistance Title: Technical Team Lead, Fire Resistance Signature: Signature: Date: 08/27/2020 Date: 08/27/2020