HomeMy WebLinkAboutLA200381-7952 Grinnell Way Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION
PAGE 2
OFFICE USE ONLY
BUILDING PERMIT TYPE REQUIRED INSPECTIONS
SINGLE FAMILY DWELLING BUILDING
DUPLEX AS BUILT
TOWNHOUSE UNITS BUILDING FINAL
DETACHED TOWN HOUSE UNIT DECK FOOTING
CONDO FIREPLACE
ACESSORY BUILDING FOOTING
REROOF FOUNDATION
RESIDE FRAMING
PORCH FRAMING
GARAGES
INSULATION
RES ADDN/REPAIR/RMDL
DECK
PORCH
GARAGES LATH
LOWER LEVEL FINISH LOWER LEVEL FINAL
ADDITION OTHER
FOUNDATION ONLY PORCH FOOTING
MISCELLANEOUS POURED WALL
DEMO SEPTIC TANK REMOVAL
MOVED SITE
MECHANICAL
CITY BUILDING VALUATION: $AIR TEST
FINAL
BUILDING PERMIT FEES ROUGH-IN
$PERMIT FEE PLUMBING
$PLAN CHECK FINAL
$SURCHARGE ROUGH-IN
$METRO SAC METER SIZE
$CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE
$CITY SEWER HOOKUP UNIT SEWER/WATER
$LANDSCAPE ESCROW SEWER/WATER
$TREE ESCROW FINAL
$MISC ESCROW STREET DRAINTILE
$PLUMBING BUILDING INFORMATION
$MECHANICAL TYPE OF CONSTRUCTION
$SEWER WATER ZONING
$OTHER CODE EDITION
$TOTAL FIRE SUPPRESSION SYSTEM
OCCUPANCY GROUP
APPROVED BY:
BUILDING INSPECTOR: Date:
PLUMBING/MECHANICAL
INSPECTOR: Date:
COMMENTS:
Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode03/22/2022dmathews
BWPsAbove30" minimum flare for porchroof/floor and deck loads.#1 Grade Southern Pinerequired for span or treatedengineered beam.
-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).PFHPFH
One or multiple power vent or
direct vent appliances or no
combustion appliancesA
One or multiple fan-assisted
appliances and power vent or
direct vent appliancesB
One atmospherically vented
gas or oil appliance or one
solid fuel applianceC
Multiple atmospherically
vented gas or oil appliances
or solid fuel appliancesD
1a) pressure factor (cfm/sf) 0.15 0.09 0.06 0.03
b) conditioned floor area (sf) (including unfinished basements) 1700
Estimated House Infiltration
(cfm): [1a x 1b] 255 0 0 0
2.a) Exhaust Capacity
continuous exhaust-only
ventilation systems (cfm): (not
applicable to balanced ventilation
systems such as HRV) 0 0 0 0
b) clothes dryer 135 135 135 135
c) 80% of largest exhaust rating
(cfm): (not applicable if
recirculating system or if powered
makeup air is electrically
interlocked and matched to
exhaust) 0 0 0 0
d) 80% of next largest exhaust
rating (cfm): (not applicable if
recirculating system or if powered
makeup air is electrically
interlocked and matched to
exhaust) 0 0 0
Total Exhaust Capacity (cfm):
[2a+2b+2c+2d] 135 135 135 135
3.a) Makeup Air Requirement
Total Exhaust Capacity (from
above) 135 135 135 135
b) Estimated House Infiltration
(from above) 255 0 0 0
Makeup Air Quantity (cfm): [3a –
3b] (if value is negative, no
makeup air is needed) -120 135 135 135
4. For Makeup Air Opening
Sizing, refer to Table 501.3.2
One or multiple power vent
or direct vent appliances or
no combustion appliancesA
One or multiple fan-assisted
appliances and power vent
or direct vent appliancesB
One atmospherically
vented gas or oil appliance
or one solid fuel
applianceC
Multiple atmospherically
vented gas or oil
appliances or solid fuel
appliancesD
Passive
makeup air
opening duct
diameterE,F,G
Type of opening or system (cfm) (cfm) (cfm) (cfm) (inches)
Passive Opening 1-36 1-22 1-15 1-9 3
Passive Opening 37-66 23-41 16-28 10-17 4
Passive Opening 67-109 42-66 29-46 18-28 5
Passive Opening 110-163 67-100 47-69 29-42 6
Passive Opening 164-232 101-143 70-99 43-61 7
Passive Opening 233-317 144-195 100-135 62-83 8
Passive Opening with
Motorized Damper 318-419 196-258 136-179 84-110 9
Passive Opening with
Motorized Damper 420-539 259-332 180-230 111-142 10
Passive Opening with
Motorized Damper 540-679 333-419 231-290 143-179 11
Powered Makeup AirH >679 >419 >290 >179 not applicable
G Barometric dampers are prohibited in passive makeup air openings when any atmospherically vented appliance is installed.
H Powered makeup air shall be electrically interlocked with the largest exhaust system.
Table 501.3.2
Makeup Air Opening Sizing Table for New and Existing Dwellings
C Use this column if there is one atmospherically vented (other than fan-assisted) gas or oil appliance per venting system or one solid fuel
appliance.
D Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically
vented gas or oil appliances and solid fuel appliance(s).
E An equivalent length of 100 feet of round smooth metal duct is assumed. Subtract 40 feet for the exterior hood and ten feet for each 90-
degree elbow to determine the remaining length of straight duct allowable.
F If flexible duct is used, increase the duct diameter by one inch. Flexible duct shall be stretched with minimal sags.
D Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically
vented gas or oil appliances and solid fuel appliances.
A Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliances or if there are no combustion
appliances.
B Use this column if there is one fan-assisted appliance per venting system. Other than atmospherically vented appliances may also be
included.
Table 501.3.1
Procedure to Determine Makeup Air Quantity for Exhaust Equipment in Dwellings
Use the Appropriate Column to Estimate House Infiltration
A Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliances or if there are no combustion appliances.
B Use this column if there is one fan-assisted appliance per venting system. Other than atmospherically vented appliances may also be
included.
C Use this column if there is one atmospherically vented (other than fan-assisted) gas or oil appliance per venting system or one solid fuel
appliance.
3
4 X 15 =60
1700
1700 X 0.02 =34
Continuous Ventilation Requirement =
Enter # of Bedrooms
Ventilation
94
47
Sq Ft of Home (including unfinished basements etc)
Total Ventilation Requirement =