Loading...
HomeMy WebLinkAboutLA203570 - 5350 178th St W Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: UPPER LEVELTOTAL2,715 SF1,288 SF--MUD/ LAUNDRYGARAGELOWER LEVELFLOOR AREA240 SFFINISHED-638 SF1,187 SFUNFINISHED-200 AMP SERVICEGARAGE LEFTSPLIT ENTRYCATEGORY ONEPHEASANT RUN AT LAKEVILLELOT 1, BLOCK 4 5350 178TH STREET WEST2x4 INTERIOR WALLS2x6 INTERIOR WALLSSHEATHING - INSULATEDCONCRETE WALLSBRICK / BRICK LEDGE2x6 EXTERIOR WALL WITH 1/2"FUTURE FINISHWALL LEGENDLAKEVILLE, MN 55044JAMES & EMILY JACOBSENSIDEWALK75 SFGARAGE SLABBASEMENT SLABFLATWORK SQUARE FOOTAGE1,426 SF608 SFNOTED OTHERWISE ON PLANS.ALL HEADERS ARE (2) 2x10 TYPICAL UNLESSWITH DIMENSIONS TO BE VERIFED SHALLTRUSS DESIGN BY MFG. TRUSSES NOTEDHEADERS:TRUSSES:BE FIELD MEASURED BY TRUSS SUPPLIERHEADER HEIGHT SCHEDULEABC6'-11-1/4"8'-0"7'-6"D118 SF6'-11-3/8"2018 BUILDING CODE2020 ENERGY CODE7TH ADDITIONFRAMERS - MAKE SURE THERE IS ICE & WATER SHIELD BEHIND FRAMERS - 1/2" SHEATHING SHOULD BE FLUSH WITH CONCRETEPORCH & DECK LEDGERSEXTERIOR FOUNDATION INSULATION3'-6" TALL FOUNDATION WALLSSIGNATURE SERIES1x6 LP TRIM1x6 LP TRIM1'-2"1'-4"ALUMINUM SOFFITCEDARMILL TEXTURELP PANEL WITH3/8" BEAD VULKEM CAULKINGALL 4 SIDES& BACK OF COLUMN1x3 LP TRIM ON FRONT1x2 ON EACH SIDESCALE: 3/4" = 1'-0"COLUMN #12 - CONCRETE STOOP8" CONC. WALLCONCRETE PORCHT.O. CONC.T.O. FTG.T.O. WALLELEV. 102'-10"SIDEWALK 75 SFConcreteStoop3'-0"8'-0"36"21'-6"3'-0"2'-0"6'-6"21'-6"2'-0"MudRoom2-24-21A-0COVER SHEETFAIRFIELD 3 BEDROOM SPLIT ENTRY GARAGE LEFT LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC627670JUNE 7, 20221JUNE 16, 20222Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode06/28/2022dmathews TOP OF FOOTINGELEV. 100'-0"ELEV. 103'-6"TOP OF 8" WALLUPPER LEVEL FLOOR5-1/2" TRIMELEVATIONTYP. @ FRONTTOP OF PLATE712BOARD5-1/2" FRIEZEBOARD5-1/2" FRIEZE 1'-6"612612SCALE: 1/4" = 1'-0"FRONT ELEVATION - BA-117127'-0"10" TRIM BOARD4'-0"1'-6"1'-6"1'-6"7121'-4"SLOPE PORCHROOF TO LINE UPUPPER FLOORROOF LINE1'-4"BOARD - HARDIE COLORPLUS PANELSBATTEN - HARDIE COLORPLUSBATTEN MUST BE 3" W/ TEXTUREVINYL LAPVINYL LAP112"3'-0" 7'-0"ELEV. 109'-3-3/8"ELEV. 117'-4-1/2"SHINGLES OVER 15# BUILDINGPAPER 15/32" OSB ROOF SHEATHING(ICE DAM EAVES)24"x24" FIXED WINDOWABOVE GARAGE DOOR24-1/8"x24-3/8" R.O.LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC6276702-20-20ELEVATIONSFAIRFIELD A-1SPLIT ENTRY 3 BEDROOM JUNE 7, 20221JUNE 16, 20222 A-2SCALE: 1/8" = 1'-0"RIGHT ELEVATIONLEFT ELEVATION2SCALE: 1/8" = 1'-0"3A-2A-21REAR ELEVATIONSCALE: 1/8" = 1'-0"6T.O. PLATET.O. FTG.ELEV. 100'-4"T.O. 8" WALLUPPER LEVEL FL.EL. 96'-4"1'-6"712ELEV. 103'-6"T.O. 8" WALLT.O. PLATE12MATCH127SCALE: 1/8" = 1'-0"ROOF PLAN4A-21212661'-0"121271'-6"ELEV. 117'-4-1/2"ELEV. 109'-3-3/8"ELEV. 117'-4-1/2"1'-0"7127:127:12MATCH 10 ROOF VENTS6:126:127:127:127:127:12T.O. FTG.EL. 100'-0"T.O. FTG.EL. 96'-4"T.O. FTG.EL. 96'-4"VINYL LAP ALL 4 SIDES6:126:126:126:12312FAIRFIELD2-20-20ELEVATIONSA-23 BEDROOM SPLIT ENTRY LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC627670JUNE 7, 20221JUNE 16, 20222Roof of covered deck removed as rear yard setbackis only enough for an uncovered deck and not a porchor other attached structure with a roof. 30'-0"19'-0"1'-412"16'-3" M.O.1'-412"11'-0"8'-3" M.O.1'-412"1'-412"1A-5SEE EWP PLAN 28'-0" 36'-0" 9'-23 4" 28'-0"13'-1014"LOWER LEVEL FLOOR PLANSCALE: 3/16" = 1'-0"1A-3FinishedBedroom #4CARPET2A-5T.O. 8" WALLEL. 103'-6"T.O. FTG.EL. 100'-0"4'-414" 8'-0" 8'-0"T.O. FTG.EL. 103'-6"T.O. 8" WALLT.O. 6" CURBT.O. 6" CURB2'-0"8'-0"FOR DRAINAGE 21'-6"6"T.O. FTG.T.O. 8" WALLUnexcavated4" CONC. SLABVARIEST.O. SLAB22'-0"5'-0"8'-0"SUMP20'-0"EL. 100'-0"6'-012" 3'-1012"UP2'-6"15'-612"28" 30"EL. 100'-0"T.O. FTG.FinishedFamily RoomCARPET6'-1112"46'-0"WALKOUT7'-5"5'-714"OUTLETMechRoom4" CONC. SLAB118 SFFURN.WATERHEATER4'-312"SOFTENEREL. 100'-0"T.O. FTG.EL. 103'-6"T.O. 8" WALL8" x 20" - TYPICALCONCRETE FOOTINGS7'-6"13'-9"11'-9"23'-012"SEE EWP PLANSTAIRSABOVESLOPE SLAB (3) 2x1090x42 SLIDER8'-0"8'-0"8'-234"8'-7"32"14'-412"5'-634"3'-1034"4'-1012"2'-6"42x60AT.O. 8" WALLT.O. FTG.EL. 100'-4"EL. 96'-4"5,000 LB. FOOTINGSTRENGTH MIXLINENFinishedBathVINYL54 SF (FLR)28"10'-0" MIN. FTG. STEP EL. 96'-4"T.O. FTG.EL. 103'-6"T.O. 8" WALL10'-0" MIN. FTG. STEP 4'-61 4"4'-11"4'-512"4'-112"EL. 96'-4"T.O. FTG.EL. 103'-6"T.O. 8" WALLFinishedBedroom #5CARPETFinishedHallCARPET4" DRAINTILE ATFOOTINGS ON EACHWALL AS MARKEDUnexcav.4" CONC. SLAB11'-534" 16'-3" 3'-612" 30" 11'-9"9'-0"5'-412"2x4 BEARING WALL12'-812"2" BRICK LEDGEEL. 102'-10"8" WALL2x4 BEARING WALL20'-612"HOSEBIBHOSEBIB4'-334"4'-014"10"6'-6" 7'-1134" 8'-3"15'-612"(2) 2x10(2) 2x10(2) 9-1/2" LSLFLUSH2'-0"VOIDDFIRE RESISTANT FLOOR SYSTEMOR 1/2" GYPSUM WALL BOARD WITH80 SQUARE FEET UNPROTECTEDSEE FRAMING PLAN 16'-0"4'-312"3'-6" 2'-6"42" OPENINGROD & SHELFROD & SHELF3"(2) 9-1/2" LSLFLUSHAPPROXIMATE LINE OF SOFFIT48x341'-6"16'-31 2"11'-81 2"3-2x66 x 6 3-2x630x30x12 FOOTINGW/ #4 BAR 12" O.C.BOTH DIRECTIONSDROPPED10'-314"P O S T APPROXIMATE LINE OF SOFFIT3-2x69-1/2" LSL'S @ 16" O.C.EL. 103'-6"EL. 102'-10"EL. 99'-4"EL. 102'-10"9-1/2" LSL'S @ 19.2 O.C.EL. 102'-10"9-1/2" LSL'S @ 16" O.C.9-1/2" LSL'S @ 19.2" O.C.2x10'S @ 16" O.C.(3) 2x10(2) 2x10(2) 2x10 (2) 9-1/2" LSL(3) 1-3/4"x 9-1/2" LSLVENTILATION REQUIREDCrawl SpaceStorage4" CONC. SLABEL. 103'-6"T.O. 6" CURBSSCDCDSSSFOOTINGS (8" x 16")INTERIOR CONCRETEFOOTINGS (8" x 16")INTERIOR CONCRETE(2) 2x106'-0" x 6'-8" PATIO9'-1114"42x6014'-0"16'-0" X 14'-0"Deck AboveTREX DECKING15'-6"4'-0"4'-0"6"STAIRS TO GRADE (3) 2x10(3) 2x10(2) 2x10(2) 2x1020'-0"6"(2) 9-1/2" LSL2x4 INTERIOR WALLS2x6 INTERIOR WALLSSHEATHING - INSULATEDCONCRETE WALLSBRICK / BRICK LEDGE2x6 EXTERIOR WALL WITH 1/2"FUTURE FINISHWALL LEGENDBATH - VINYLMECHANICAL ROOMBEDROOM #5 - CARPETFAMILY ROOM - CARPETHALL & LINEN - CARPETBEDROOM #4 - CARPET79 SF118 SF215 SF634 SF79 SF180 SFROOM SIZESTOTAL1,305 SFHEADER HEIGHT SCHEDULEABC6'-11-1/4"8'-0"7'-6"D6'-11-3/8"MIN. TREAD 10"STAIR REQUIREMENTSMAX. RISE 7-3/4"10"734"MIN. NOSING 3/4"MAX. NOSING 1-1/4"1-1/4"LOWER LEVELA-32-20-20SPLIT ENTRY 3 BEDROOM FAIRFIELD LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC627670FLOOR PLANJUNE 7, 20221JUNE 16, 20222UFER Ground555555 24"x24" FIXED WINDOWABOVE GARAGE DOOR24-1/8"x24-3/8" R.O.A-4SCALE: 3/16" = 1'-0"1UPPER LEVEL FLOOR PLANUPBedroom #3CARPETMudRoomLVP61 SF (FLR)GAS KitchenLVPDWREF.30x36 SHBedroom #2CARPETMasterBedroomCARPETDiningLVP5'-0"9'-538"6'-258"(3) 2x106'x 6'-8" PATIO5'-6"6'-018"20'-0"30'-0"19'-0"1'-6"2x4 STUD WALLS @ 16" O.C. W/TYPICAL GARAGE WALL1/2" - EXTERIOR SHEATHING16'-0"1'-6"ADJACENT TO HOUSEBD ON ALL WALLS5/8" TYPE "X" GYP.21'-6"PRE-ENGINEERED TRUSSES(2) 1-3/4"x11 7/8" LSL16'x7' O.H. DOOR@ 24" O.C.Garage4" CONC. SLAB11'-0"8'-0"1'-6"1'-6"(2) - 1 3/4" x 9 1/2" LSL8'x7' O.H. DOOR7'-1"1'-1134"(2) 2x10DNLndryLVP49 SF (FLR)W 1'-534"6'-614" D 24x36 (2) 2X10 ROD & SHELF28"28"TUB ACCESS30"30"30"ROD & SHELF HALF WALL60x34 LivingRoomLVP30x60SH(3) 9-1/2" LVL2'-6"BathVINYL37 SF (FLR)9'-2"11'-534"4'-9"5'-834"6'-012" 28'-0"8'-0" (2) 36X60 MULLED 28"ROD & SHELFW.I.C.CARPET46'-0"42x60 SH42x60 SH5'-778"5'-8"28'-0" 36'-0" 2'-0"4'-6"32"8'-0"5'-0"CONCRETE STOOP11'-2"11'-8"12'-834" 3'-6"5'-7"6'-214"14'-9"1A-52A-55'-634"8'-0"16'-0"8'-0"2'-10"8'-0"3'-6"36" 4'-0" BI-FOLD 4'-0" BI-FOLD ROD & SHELF18"11'-914"LINEN5'-0" CLR 48x60FIX30x60SH7'-7"12'-1114"3'-1034"4'-1112"3'-6"3'-9"CLR3'-6" CLR 3'-9"48" VANITY2'-8"4'-0"PANTRYM. BathVINYL37 SF (FLR)3'-1012"32"22'-0"6'-0"+36"AAAAMULLED2'-1112"10"HallLVP10'-7"12'-1134"15'-014" 4'-414"A24"x 69"ISLANDEntryVINYL4'-0" BI-FOLD5'-738"5'-278"1'-1012" 3'-6"4'-334"(2) 7-1/4" LSL(2) 2x105'-10"1'-012"3" 5'-1012" HALF WALL (+42") 10"10"6'-1" 8'-0" 8'-3"15'-612"(2) 2x10(2) 2X10 (2) 2x10(2) 2x10(2) 2x10RANGEFLATCEILINGCARPETCARPETCARPETPORTAL FRAME4'-3"9"A4'-014"PANELACCESSATTIC22x304'-914"RECYCLEPANELACCESSATTIC22x3048" VANITYTOP SIZE 35-1/2x72PANELACCESSATTIC22x30 18"CATHEDRAL VAULTS ADJOINING AN OUTSIDE WALL MUST HAVE THE BOTTOM CHORD MATCHING THE VAULT AT THE GABLE.SWITCH UNDER SINKDISHWASHER & DISPOSALSSSSSCDELEVATION B5'-2"5'-0" 3'-10"16'-0" X 14'-0"Covered DeckTREX DECKING5'-0"5'-0" 4'-0"STAIRS TO GRADE 15'-6"14'-0"4'-0"FIB. BASE 8'-0" C.T. WALLS 2x4 INTERIOR WALLS2x6 INTERIOR WALLSSHEATHING - INSULATEDCONCRETE WALLSBRICK / BRICK LEDGE2x6 EXTERIOR WALL WITH 1/2"FUTURE FINISHWALL LEGENDHEADER HEIGHT SCHEDULEABC6'-11-1/4"8'-0"7'-6"D6'-11-3/8"MIN. TREAD 10"STAIR REQUIREMENTSMAX. RISE 7-3/4"10"734"MIN. NOSING 3/4"MAX. NOSING 1-1/4"1-1/4"FINISHED ROOM SIZESMUD ROOM - LVPLAUNDRY - LVPLIVING ROOM - LVPKIT/DINING - LVP61 SF49 SF194 SF243 SFENTRY - LVP72 SFMASTER BEDROOM - CARPET190 SFHALL & LINEN - LVP49 SFMAIN BATH - VINYL55 SFBEDROOM #3 - CARPET149 SFBEDROOM #2 - CARPET146 SFMASTER BATH - VINYL58 SFSTAIRS - CARPET34 SFFAIRFIELD2-20-20UPPER LEVEL PLANA-43 BEDROOM SPLIT ENTRY LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC627670 GARAGE RIGHT JUNE 7, 20221JUNE 16, 20222-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).55PFHPFH (2) 2x10(2) 2x10(1) 2x10 2x10 JOISTS - SOUTHERN YELLOW PINE .40 TREATEDMAINTENACE FREE DECKING - TREX 3-2x10 BEAMS SOUTHERN YELLOW PINE - .40 TREATED6x6 POSTS PONDEROSA PINE - .60 TREATEDDECK / ROOF FRAMING PLANSCALE: 1/4" = 1'-0"1x12 MAINTENANCE FREE SKIRT BOARD15'-6"x14'-0" Covered DeckSTAIRSGRIPPABLE HANDRAILREQUIREDSTRAP STRINGERSTO RIM7-3/4" MAX RISE10" MAX RUNLESS THAN 4" OPENINGON STAIR RISERS4'-6"4'-0"4'-0"4'-6"EXISTING HOUSE1DTL20'-0"@ 24" O.C.PRE-ENGINEERED TRUSSES(2) 9-1/2" LSL - CONTINUOUS(2) 9-1/2" LSL - CONTINUOUS(2) 9-1/2" LSL - CONTINUOUS7'-9"7'-9"7'-0"7'-0" 14'-0"15'-6"(3) 2x10(2) 2x10 (1) 2x10(2) 2x10(1) 2x10 DECK FOOTING PLANSCALE: 1/4" = 1'-0"15'-6"x14'-0" Covered Deck15'-6"14'-0" 13'-914"7'-314"7'-914"234"STAIRS TO GRADE 234"4'-6"4'-6"4'-0"234"EXISTING HOUSE15'-6"2DTLPIERSINSTRUCTIONS FORSEE INSTALLATIONDIAMOND PIER FOOTINGSDP-5020'-0"4'-0"6x6 POSTT.O. DECKING3'-0"312"T.O. RAILINGWESTBURYBOLT4"2x46X6 POSTS(3) 2x10 BEAMSFLUSH AT CORNER3RAILING DETAILSDTLSCALE: 3/8" = 1'-0"4" SPHERE CANNOT PASSPOST AT DECK RAILINGMAINTENANCE FREE DECKRAILINGWESTBURYRAILINGHOLDER REQUIRED TOANCHOR STRAP OR POSTSLOPE TOP OF PIERCONCRETE PIER FOOTING1'-6"512"POST6x6 DECK SUPPORT5'-0"1'-0"FLARE BOTTOM OF FOOTINGTO A MINIMUM DIAMETER OF 18"CONNECT POST TO FOOTING4POST & PIER DETAILDTLSCALE: 1/2" = 1'-0"1ST FLOORBOISE RIM BOARD (EXTERIOR)1-1/8" OSB RIM BOARD(R-20)2x10 FLOOR JOISTS2x10 JOISTS @ 12" O.C.2x10 DECK LEDGERDTT1Z DECK TENSION TIEDECK LEDGER HANGER4"5CONNECTION DETAILDTLSCALE: 3/4" = 1'-0"BOLT THROUGH BLOCKINGLATERAL LOADRIGID METAL FLASHING FAIRFIELD2-20-20UPPER LEVEL PLANDECK3 BEDROOM SPLIT ENTRY LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC627670 GARAGE RIGHT JUNE 7, 20221JUNE 16, 20222Roof of covered deck removed as rear yard setbackis only enough for an uncovered deck and not a porchor other attached structure with a roof. SCALE: 1/4" = 1'-0"BUILDING SECTIONA-518'-11 8" 8'-118"MudRoomW/ WOOD CAP42" H. WALLGaragePRESSURE TREATED 2x6 SILLPLATE W/ SILL SEAL INSUL. &3/8" ANCHOR BOLTS @ 6'-0" O.C.ELEV. 103'-6"ELEV. 99'-6"T.O. FTG.T.O. 4" CURB2x10's @ 16" O.C.8'-11 8"(3) LSLSTRINGERSSTAIRSTYP. ALLTOP OF SLAB4" CONCRETE SLABTOP OF FOOTINGELEV. 100'-0"ELEV. 100'-4"ELEV. 108'-5-1/8"TOP OF PLATEFIRST FLOOR DIAG. WIND BRACINGAS REQUIREDR-44 ROOF INSULATIONBathBathHallLINE OF VAULT BEYONDBedroom #2TOP OF PLATE2x6 FRAMING @ 16" O.C.9'-058"9-1/2" JOISTS8'-113 8"MechRoomBathW.I.C.HallELEV. 109'-3-3/8"ELEV. 117'-4-1/2"5'-10"4'-97 8"ELEV. 100'-0"T.O. FTG.3'-6"BUILDING SECTIONSCALE: 1/4" = 1'-0"2A-5TRUSSES @ 24" O.C.FinishedBedroom #5LivingRoomG.B. OVER 4 MIL POLYOR 1/2" SAG-RESISTANT5/8" TYPE "X" GYP. BD.V.B.8'-118" 8'-11 8"ELEV. 100'-0"TOP OF FOOTINGTOP OF 8" WALLELEV. 103'-6"ELEV. 108'-5-1/8"8'-11 8"BathMasterBedroomELEV. 109'-3-3/8"FIRST FLOOR TOP OF PLATETOP OF PLATEELEV. 117'-4-1/2"PRE-ENGINEERED ROOFDIAG. WIND BRACINGAS REQUIREDVAULT @ LIVING, DINING & KITCHEN9-1/2" JOISTS2x6 FRAMING @ 16" O.C.9-1/2" JOISTS8'-113 8"FinishedLiving RoomSEAL ALL JOINTS, CRACKS, OR OTHEROPENINGS WITH POLYURETHANE CAULKFOR RADON PROTECTIONFIRE RESISTANT FLOOR SYSTEMOR 1/2" GYPSUM WALL BOARD80 SQUARE FEET UNPROTECTED3/4" OSB FLOOR SHEATHINGGLUED AND NAILED7'-35 8"6x6 POSTDROPPED 9-1/2" LSLFAIRFIELD12-14-20SECTIONS & DETAILSA-53 BEDROOM SPLIT ENTRY LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC627670JUNE 7, 20221JUNE 16, 20222 BUILDING SECTION1A-7SCALE: 1/2" = 1'-0"4" CONCRETE SLAB8" x 20" CONC. FTG'S1/2" ANCHOR BOLTSPLATE W/ SILL SEAL INSUL. &PRESSURE TREATED 2x6 SILLMAINTAIN A MIN. CL.OF 6" FROM GRADETO BOTTOM OF SIDING1/2" SHEATHING FOREXTERIOR SHEATHINGBLOCKING AT FOUNDATIONWALLS PARALLEL TO FRAMINGDUCTSPACETYPICAL UNLESS NOTEDOTHERWISEOR 1/2" SAG-RESISTANT5/8" TYPE "X" GYP. BD.PRE-ENGINEERED ROOFTRUSSES @ 24" O.C.MIN. 6" ENERGY HEALR-20 SPRAY FOAM @ RIM1/2" ANCHOR BOLTS@ 6'-0" O.C. (8" EMBED.)5,000 LB. FOOTINGSTRENGTH MIX3/4" OSB FLOOR SHEATHINGGLUED AND NAILED8'-11 8"ELEV. 100'-0"TOP OF FOOTINGTOP OF 8" WALLELEV. 103'-6"ELEV. 108'-5-1/8"8'-118"ELEV. 109'-3-3/8"FIRST FLOOR TOP OF PLATETOP OF PLATEELEV. 117'-4-1/2"BLOCKBLOCKBOISE RIM BOARD1-1/8" OSB RIM BOARD2x6 STUD WALLS @16" O.C. W/ (R=21) FIBERGLASS BATTINSULATION, 4 MIL POLYVAPOR BARRIER & 1/2"GYPSUM BOARD INSIDE (R-20)2x6 STUD WALLS @16" O.C. W/ (R=21) FIBERGLASS BATTINSULATION, 4 MIL POLYVAPOR BARRIER & 1/2"GYPSUM BOARD INSIDE R-49 ROOF INSULATIONSHINGLES OVER 15# BUILDINGPAPER 15/32" OSB ROOF SHEATHING(ICE DAM EAVES8" POURED WALLWATERPROOFING1) COAT EXTERIOR W/ POLYUREA WATER-PROOFING3" EXTERIOR FOAM INSULATION ATLOOKOUT/WALKOUT SIDE WALLS. 2"FOAM AT FULL BASEMENT & 4' FROSTFOOTINGS.2) FOAM W/ POLYURETHANE (R-15)6 MIL POLY SLIP SHEET OVERFOAM PRIOR TO BACKFILLAS REQUIRED PER CITYSEE EWP PLAN FOR3) APPLY ABOVE GRADEFOUNDATION COATINGSPACING & JOIST TYPE9-1/2" TJI JOISTS(FINISHED BASEMENT)9-1/2" LSL JOISTS(UNFINISHED BASEMENT)FAIRFIELD12-14-20SECTIONS & DETAILSA-63 BEDROOM SPLIT ENTRY LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC627670JUNE 7, 20221JUNE 16, 20222 %12;4+)*6*#0510)4172..%‹&GUETKRVKQP&CVG4GXKUKQP0QXGODGT2TQLGEV0WODGT&CVG55JGGVUQH2TKPV0COG5KIPGF.KEGPUG0WODGTÄÄ&CVG+JGTGD[EGTVKH[VJCVVJKURNCPURGEKHKECVKQPQTTGRQTVYCURTGRCTGFD[OGQTWPFGTO[FKTGEVUWRGTXKUKQPCPFVJCV+COCFWN[.KEGPUGF2TQHGUUKQPCN'PIKPGGTWPFGTVJGNCYUQHVJG5VCVGQH/KPPGUQVC-KNOGT.CPG05WKVG2N[OQWVJ/06GNÄÄYYYJCPUQPITQWROPEQO2.#055*190.+)*6+0$#%-)4170&#4'(14.1%#6+104'('4'0%'10.;2.#0016'5#0&'.'/'0655*190.+)*6/#;0160'%'55#4+.;57221466*'*#0510)4172ž5&'5+)0(CKTHKGNF/QFGN)CTCIG.GHV/KPPGUQVC%QPUVTWEVKQP5%12'&'5+)0#0&&'6#+.1(6*'/#+09+0&(14%'4'5+56+0)5;56'/(14#5+0).'Ä(#/+.;4'5+&'0%'%105647%6+10+561$'+0#%%14&#0%'9+6*6*+5&1%7/'0656#0&#4&+0&7564;24#%6+%'#0&6*'%1&'016'56*'5'&1%7/'065#22.;615647%674#.10.;4'('461%105647%6+10&1%7/'065(14/14'+0(14/#6+10#..':6'4+149#..5#4'61$'%105647%6'&+0#%%14&#0%'9+6*6*'(1..19+0)%4+6'4+#7019*+%*/''6514':%''&56*'4'37+4'/'0651(%1&'5'%6+104Ä952 %5Ä952#Z567&552#%'&"1%$':6'4+145*'#6*+0)/+05647%674#.2#0'.5*'#6*+0)YF0#+.5"1%#62#0'.'&)'5#0&1%#6+06'4/'&+#6'5722146514)#7)'56#2.'5"52#%+0)%#/+0+/7/Ä+0%*911&5647%674#.2#0'.%140'44'67405*#..$'2418+&'&#6$16*'0&51(#%106+07175.;Ä5*'#6*'&$4#%'&9#...+0'+0#%%14&#0%'9+6*(+)74'4+0.+'71(6*'%140'44'6740#6+'Ä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Ä'55'06+#.5647%674'#0&#4'':%.7&'&(41/6*'18'4#../#+09+0&(14%'5;56'/1(6*'*1/'2418+&'%1&'4'37+4'&.'&)'46'05+10#0&72.+(6%100'%6+105%106#%66*'*#0510)4172+(#4+)+&&'5+)01(6*'5'#4'#5+5&'5+4'&/#6'4+#.59#..567&5 ž14.'55 52(567&)4#&'14$'66'49#..567&5 18'4ž 52(01)4#&'14$'66'4&+/'05+10#..7/$'452(01)4#&'14$'66'464'#6'&.7/$'45;201)4#&'14$'66'4.5.9+&6*Ä'14$'66'4.8.9+&6*Ä'14$'66'4.1#&5411(5019.1#&Ä25(411(&'#&.1#&25((.114.+8'.1#&25((.114&'#&.1#&25(9+0&.1#&/2*':2$%1&'/+00'516#4'5+&'06+#.%1&';QWPIHKGNF*QOGU+PE&QFF$QWNGXCTF.CMGXKNNG/00KEM*CPUQPZ$.1%-+0)$'69''064755'50#+.'&616122.#6'5Y  F0#+.5'#%*0#+.'#%*,1+56616122.#6'Y  F61'0#+.50#+.$1661/2.#6'61$.1%-+0)Y  F0#+.5'8'4;+06'4+14$'#4+0)9#..+06'4+14010Ä$'#4+0)9#..2418+&'(7..&'26*$.1%-+0)$'69''0,1+5650#+.'&616122.#6'5Y  F0#+.5'#%*0#+.$1661/2.#6'61$.1%-+0)Y  F0#+.5'8'4;2418+&'64755&+4'%6.;+0.+0'Y$4#%'&9#..2#0'.(#56'0'&612.#6'5YF61'0#+.5"1%2418+&',1+56&+4'%6.;+0.+0'Y$4#%'&9#..2#0'.(#56'0'&612.#6'5YF61'0#+.5"1%6*+55*''654'24'5'065#%1/2.'6'&'5+)01(6*'/#+09+0&(14%'4'5+56+0)5;56'/(146*''06+4'4'5+&'06+#.5647%674'6*'.1%#6+10#0&.'0)6*1('#%*$4#%'&9#..2#0'.#0&'0)+0''4'&9+0&4'5+56+0)'.'/'066*#6+54'37+4'&(146*'*#0510)4172ž5&'5+)0+55*190106*'5647%674#.&4#9+0)59#..501652'%+(+%#..;.#$'.'&106*'2.#05/#;$'56#0&#4&(4#/+0)5'%6+1055*190&'2+%6%100'%6+1051($4#%'&9#..2#0'.561411(64755'5#$18'61,1+56564755'5$.1%-+0)#$18'#0&61,1+56564755'5$.1%-+0)$'.196*'5'2#0'.5#4'0160'%'55#4+.;4'37+4'&61#.+)0$76/#;&'2'0&+0)102.#0.#;176411(64755'5$4#%'&9#..2#0'.(.#6Z"1% /+0  2'4$4#%'&9#..2#0'. 5+/2510#(4#/+0)#0).''#%*'0&  ŒZ0#+.52418+&'9+&6*9'$56+(('0'4(14#66#%*/'061((4#/+0)#0).'$4#%'&9#..2#0'.  ŒZ0#+.55+/2510#(4#/+0)#0).''#%*'0&(.114,1+5652418+&'9+&6*9'$56+(('0'4(14#66#%*/'061((4#/+0)#0).'$4#%'&9#..2#0'.  ŒZ0#+.55+/2510#(4#/+0)#0).''#%*'0&(.114,1+565(.#6Z"1% /+0  2'4$4#%'&9#..2#0'. (.#6Z"1% /+0  2'4$4#%'&9#..2#0'. $4#%'&9#..%100'%6+10$4#%'&9#..%100'%6+10 411(64755'5 (.114,1+565 &'6#+.55*190#$18'#4'#.6'40#6+8'%100'%6+10561$'75'&9*'0$4#%'&9#..2#0'.&1'5016#.+)09+6*(4#/+0)':6'4+14010Ä$'#4+0)9#..411(64755(#56'0'&612.#6'5YF61'0#+.5"1%0#+.4+/6122.#6'5YF61'0#+.5"1%0#+.$1661/2.#6'614+/,1+56$.1%-+0)Y  F0#+.5'8'4;411(64755'5(#56'0'&612.#6'5Y  F61'0#+.5 5+/2510*%.+2Z$.1%-+0)$'69''064755'50#+.'&616122.#6'5Y  F0#+.5'#%*0#+.'#%*,1+56616122.#6'5Y  F61'0#+.50#+.$1661/2.#6'614+/,1+56$.1%-+0)Y  F0#+.5'8'4;(4#/'Z$1:#4170&52#%'$'69''064755Y5#/'5*'#6*+0)#0&(#56'0+0)#59#..$'.19 144'2.#%'Y#&'37#6'&'26*Z/'/$'4 Z911&5%4'95"1%+056#..'&+0#&&+6+10610#+.5 /#+0722'4.'8'.411(64755$'#4+0)9#..510.; ':6'4+14$'#4+0)9#..4'24'5'065(+)74'4  Y,1+565Y,1+565+0&+%#6'5':6'4+14$4#%'&9#..2#0'.Y5*'#6*+0)10':6'4+14(#%'+0#%%14&#0%'Y016'2418+&'+0%4'#5'&(#56'0+0)4'37+4'/'065#55*190$'.19+0&+%#6'5'0)+0''4'&9+0&4'5+56+0)'.'/'06561$'%105647%6'&#55*190+06*'&'6#+.5*''65 /+0.'0)6* /+0.'0)6* +0&+%#6'5+06'4+14$4#%'&9#..2#0'.Y);257/5*'#6*+0)$16*(#%'59+6*'+6*'4(#56'0'4126+10.+56'&+0016'52#%'&#61%2418+&'+0%4'#5'&(#56'0+0)4'37+4'/'065#55*190$'.192NCP7RFCVGÄÄ5(4#/+0)&'6#+.)#4#)'(41062146#.(4#/'016'+0(1#22.+'55;//'64+%#..;#%4155&'6#+.2#46+#..19'4.'8'.*175'2.#05*190(14.1%#6+104'('4'0%'10.;54'('4'0%'2.#0/#+0.'8'.*175'2.#05*190(14.1%#6+104'('4'0%'10.;54'('4'0%'2.#02156Ä+056#..'&*1.&190126+105(4#/+0)&'6#+.%10%4'6'(170&#6+10$'.195+/2510*66*1.&190#0%*14#6.1%#6+1055*190YŒZ.10)5+/25106+6'0*&5%4'9Ä+0#0%*14žÄžÄžÄ/#:(#56'06122.#6'61*'#&'4Y  4195F5+0-'40#+.5"1%  ZZ$'#4+0)567&   ZZ(7..*'+)*6567&'#%*'0&1(*'#&'4.1%#6'2#0'.,1+069+6*+0žÄ(41/%'06'41(9#..*'+)*6#54'3ž& Z51.+&$.1%-+0)4'37+4'&#65*'#6*+0),1+06  ZZ$'#4+0)567&5/+0 8'4+(;Y5722.+'4 5+/251056*&'/$'&&'&*1.&190#0%*14#6.1%#6+1055*190 4'('4615(14#.6'40#6+8'126+105 (170&#6+109#..$'.19.'0)6*1(%106+07175*'#&'4Œ#0%*14$1.6 /+0'/$'& YZZ2.#6'9#5*'40#+.5*'#6*+0)61*'#&'4YF0#+.5"1%'#9#;6;25/#..*#6%*#4'#+0&+%#6'5146*+%-'42.;911&1415$5*'#6*+0)#22.+'&61':6'4+145+&'1(567&5 0#+.5*'#6*+0)#4170&2'4+/'6'4Y  4195F0#+.5"1%56#))'4'& 612.#6'5$.1%-+0)"1% 5+/2510/56%564#210+05+&'(#%'1(9#.. 2418+&'52#%'461(.75*176*'#&'4619#..567&6*+%-0'55 (#56'0-+0)567&61*'#&'4Y  4195F5+0-'40#+.5"1%žÄ%106+07175.5..8.*'#&'46157221468'46+%#..1#&5$;5722.+'4 /+09+&6* /+0&'26*4'3ž& 2418+&'ZZ+0(+..9#..#$18'*'#&'4#54'3ž&.#4)'*#6%*#4'#+0&+%#6'5146*+%-'42.;911&1415$5*'#6*+0)#22.+'&61':6'4+145+&'1(567&5Y56#0&#4&0#+.+0)(#56'0(4#/+0)#$18'#55*190(14$4#%'&9#..2#0'.5$4#%'& 9#...+0' $4#%'& 9#...+0' $4#%'& 9#...+0' $4#%'& 9#...+0' $4#%'& 9#...+0' $4#%'& 9#...+0'$4#%'&9#...+0'$4#%'&9#...+0'$4#%'&9#...+0'$4#%'&9#...+0'$4#%'&9#...+0' Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 %105647%62146#.(4#/'#55*190+05 Ä(6 $4#%'&9#...+0' Ä(6 Ä(6 Ä(6 6*'4'37+4'/'0655*190&+4'%6.;#$18'10.;#22.;619#.-176(170&#6+102NCP7RFCVGÄÄ Products PlotID Length Product Plies Net Qty E28' 28' 0" 9 1/2" TJI 210 joist 1 25 E18' 18' 0" 9 1/2" TJI 210 joist 1 3 TS1 28' 0" 1 1/2" x 9 1/2" 1.5E TimberStrand LSL 1 3 TS2-2 24' 0" 1 1/2" x 9 1/2" 1.5E TimberStrand LSL 2 6 3-9.5" LSL-22' 22' 0" 1 3/4" x 9 1/2" 1.55E TimberStrand LSL 3 3 2-9.5" LSL-6' 6' 0" 1 3/4" x 9 1/2" 1.55E TimberStrand LSL 2 4 Rim 16' 0" 1 1/8" x 9 1/2" TJ Rim Board 1 10 3-2x10 Trtd. 16' 0" 2 X 10 SP No.1 P 3 3 3-2x10 Trtd. 14' 0" 2 X 10 SP No.1 P 3 3 2-2x10 Trtd. 5' 0" 2 X 10 SP No.1 P 2 2 2-2x10-6' 6' 0" 2 x 10 SPF No.1/No.2 2 2 2-2x10-5' 5' 0" 2 x 10 SPF No.1/No.2 2 2 Wall Framing PlotID Length Product Plies Net Qty TSHd1-2 8' 0" 1 3/4" x 9 1/2" 1.55E TimberStrand LSL 2 2 TSHd2-2 4' 0" 1 3/4" x 9 1/2" 1.55E TimberStrand LSL 2 2 BBOHd1-3 9' 0" 2 x 10 SPF No.1/No.2 3 3 BBOHd2-2 5' 0" 2 x 10 SPF No.1/No.2 2 2 BBOHd3-2 4' 0" 2 x 10 SPF No.1/No.2 2 2 BBOHd3-2 3' 0" 2 x 10 SPF No.1/No.2 2 2 Framing Connector Summary PlotID Qty Manuf Product Face Nails Top Nails Member Nails Web Stiff H1 3 Simpson LUS210-2 8- 10dx1.5 - 6- 10d No H2 3 Simpson IUS2.06/9.5 8- 10dx1.5 - 2- Strong-Grip No Start Joist Layout Here. 16" o/c 19.2" o/c CS CS 2-2x10-6'2-2x10-5'2-9.5" LSL-6' 2-9.5" LSL-6' 3-9.5" LSL-22' 6x6 Post BBOHd3-2 BBOHd3-2 BBOHd1-3E28'E28'RimRimRimRimRim Rim Rim Rim 1' 4"E18'E18'E18'20' 0" BBOHd2-2 TSHd2-2TSHd1-2 2-2x10 Trtd.3-2x10 Trtd.3-2x10 Trtd. TS1 19.2" O.C. TS2-2 19.2" O.C. H1 E28' 19.2" O.C. H2 E28' 16" O.C. 3-2x63-2x6 LSL Joists in this area 2 Trimmers Customer:Job Name:Address/Lot:Youngfield HomesJacobsen5350 178th Street WCity, State:Lakeville, MNPlan/Model #:Fairfield BJob Number:25568Lyman Lumber Company18900 West 78th StPO Box 130Chanhassen, MN(952) 470-4800Sheet: 1 of 2 A complete Javelin™ framing plan requires the Framer's Pocket Guide See the Framer's Pocket Guide for Product Trademark Information Drawn By:Jeff D.Drawn Date:6/1/22Revised By:Revision Date:Revision #:SALES PRESENTATION DRAWING:NO STRUCTURAL OR DIMENSIONAL CHECK HAS BEEN PERFORMED ON THIS DRAWING. LYMAN LUMBER COMPANY IS ONLY RESPONSIBLE FOR INDIVIDUAL MEMBER DESIGN,BASED UPON THE ASSUMED VERTICAL LOADS. BUILDER IS RESPONSIBLE FOROVERALL DESIGN OF THE STRUCTURE AND IT IS STRONGLY RECOMMENDEDTHAT ALL DRAWINGS AND CALCULATIONS BE REVIEWED BY THEENGINEER OF RECORD FOR THIS PARTICULAR PROJECT.Lack of proper bracing during construction can result in serious accidents. Observe the following guidelines: 1. All blocking, hangers, rim boards and rim joists at the end supports of the TJI® joists must be completely installed and properly nailed. 2. Laterial strength, like braced end wall or an existing deck, must be established at the ends of the bay. This can also be accomplished by a temporary or permanent deck (sheathing) fastened to the first 4 feet of joists at the end of the bay. 3. Safety bracing of 1x4 (minimum) must be nailed to a braced end wall or sheathed area (as in note 2) and to each joist. Without this bracing, buckling sideways or rollover is highly probable under light construction loads - such as a worker or one layer of unnailed sheathing. 5. Ends of cantilevers require safety bracing on both the top and bottom flanges. 6. The flanges must remain straight within 1/2" from true alignment. 4. Sheathing must be completely attached to each TJI® joist before additional loads can be placed on the system. WARNING NOTES: WARNING Joists are unstable until braced laterally Bracing Includes: Blocking Hangers Sheathing Rim Board Strut LinesRim Joist DO NOT stack building materials on unsheathed joists. Stack only over beams or walls. DO NOT walk on joists that are lying flat. DO NOT walk on joists until braced. INJURY MAY RESULT. Weyerhaeuser, iLevel®, Microllam®, Parallam®, Silent Floor®, TimberStrand®, TJI®, TJ® and Trus Joist® are registered trademarks of Weyerhaeuser NR. © 2012 Weyerhaeuser NR Company. All rights reserved. Header Spans: Up to 4'-11" = 1 Trimmer 5'-0" and Bigger = 2 Trimmers *** Unless Noted Otherwise *** Products PlotID Length Product Plies Net Qty 2-11.875" LSL-20' 20' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2 2-7.25" LSL-10' 10' 0" 1 3/4" x 7 1/4" 1.55E TimberStrand LSL 2 2 2-2x10-5' 5' 0" 2 x 10 SPF No.1/No.2 2 2 Wall Framing PlotID Length Product Plies Net Qty MHd1-2 10' 0" 1 3/4" x 9 1/2" 2.0E Microllam LVL 2 2 TSHd1-2 10' 0" 1 3/4" x 9 1/2" 1.55E TimberStrand LSL 2 2 BBOHd2-3 7' 0" 2 x 10 SPF No.1/No.2 3 3 BBOHd1-2 7' 0" 2 x 10 SPF No.1/No.2 2 2 BBOHd3-2 4' 0" 2 x 10 SPF No.1/No.2 2 10 BBOHd3-2 3' 0" 2 x 10 SPF No.1/No.2 2 4 BBOHd3-2 BBOHd3-2 BBOHd3-2 BBOHd2-3 MHd1-22-2x10-5' BBOHd3-2BBOHd3-2BBOHd3-2 BBOHd1-2 2-11.875" LSL-20' 2-7.25" LSL-10' BBOHd3-2 TSHd1-2 Customer:Job Name:Address/Lot:Youngfield HomesJacobsen5350 178th Street WCity, State:Lakeville, MNPlan/Model #:Fairfield BJob Number:25568Lyman Lumber Company18900 West 78th StPO Box 130Chanhassen, MN(952) 470-4800Sheet: 2 of 2 A complete Javelin™ framing plan requires the Framer's Pocket Guide See the Framer's Pocket Guide for Product Trademark Information Drawn By:Jeff D.Drawn Date:6/1/22Revised By:Revision Date:Revision #:SALES PRESENTATION DRAWING:NO STRUCTURAL OR DIMENSIONAL CHECK HAS BEEN PERFORMED ON THIS DRAWING. LYMAN LUMBER COMPANY IS ONLY RESPONSIBLE FOR INDIVIDUAL MEMBER DESIGN,BASED UPON THE ASSUMED VERTICAL LOADS. BUILDER IS RESPONSIBLE FOROVERALL DESIGN OF THE STRUCTURE AND IT IS STRONGLY RECOMMENDEDTHAT ALL DRAWINGS AND CALCULATIONS BE REVIEWED BY THEENGINEER OF RECORD FOR THIS PARTICULAR PROJECT.Lack of proper bracing during construction can result in serious accidents. Observe the following guidelines: 1. All blocking, hangers, rim boards and rim joists at the end supports of the TJI® joists must be completely installed and properly nailed. 2. Laterial strength, like braced end wall or an existing deck, must be established at the ends of the bay. This can also be accomplished by a temporary or permanent deck (sheathing) fastened to the first 4 feet of joists at the end of the bay. 3. Safety bracing of 1x4 (minimum) must be nailed to a braced end wall or sheathed area (as in note 2) and to each joist. Without this bracing, buckling sideways or rollover is highly probable under light construction loads - such as a worker or one layer of unnailed sheathing. 5. Ends of cantilevers require safety bracing on both the top and bottom flanges. 6. The flanges must remain straight within 1/2" from true alignment. 4. Sheathing must be completely attached to each TJI® joist before additional loads can be placed on the system. WARNING NOTES: WARNING Joists are unstable until braced laterally Bracing Includes: Blocking Hangers Sheathing Rim Board Strut LinesRim Joist DO NOT stack building materials on unsheathed joists. Stack only over beams or walls. DO NOT walk on joists that are lying flat. DO NOT walk on joists until braced. INJURY MAY RESULT. Weyerhaeuser, iLevel®, Microllam®, Parallam®, Silent Floor®, TimberStrand®, TJI®, TJ® and Trus Joist® are registered trademarks of Weyerhaeuser NR. © 2012 Weyerhaeuser NR Company. All rights reserved. Header Spans: Up to 4'-11" = 1 Trimmer 5'-0" and Bigger = 2 Trimmers *** Unless Noted Otherwise *** Print Name: Signed: Nick Hanson I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. License Number:1-1-21 46665Date: SCOPE OF DRAWINGS: THESE CAST-IN-PLACE CONCRETE FOUNDATION WALL GUIDELINE DRAWINGS ARE PREPARED AND CERTIFIED BY THE HANSON GROUP IN COMPLIANCE WITH THE MINNESOTA RESIDENTIAL CODE. THESE DRAWINGS CONTAIN STRUCTURAL INFORMATION FOR USE IN THE CONSTRUCTION OF STANDARD C.I.P. CONCRETE FOUNDATIONS FOR TYPICAL RESIDENTIAL CONDITIONS. THIS INFORMATION IS RELEVANT TO THE CONCRETE CONTRACTOR, THE GENERAL CONTRACTOR, AND THE FRAMING CONTRACTOR. THESE DRAWINGS EXPIRE ON DECEMBER 31, 2021. 2021 FOUNDATION GUIDE: DRAWING INDEX: SCOPE, INDEX, & CERTIFICATION S0 USE GUIDELINES AND MATERIALS S1 GENERAL NOTES S2 STEP FOOTING DETAIL S3 WALKOUT WALL DETAIL S4 LOOKOUT/KNEE WALL DETAIL S5 EXTERIOR LOW GRADE FOUNDATION DETAIL S6 BASEMENT WALL DETAIL S7 BASEMENT WALL VERTICAL REINFORCING TABLE S8 BRICK LEDGE DETAILS S9 FLOOR MEMBER BEARING DETAIL AND CONNECTION TABLE S10 BASEMENT WALL ANCHOR SPACING TABLE S11 NON-BEARING WALL JOIST BLOCKING DETAIL S12 NON-BEARING WALL TRUSS BLOCKING DETAIL S13 WINDOW WELL DETAIL S14 STEPPING DOWN WALL WITH GRADE DETAIL S15 COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 150 1.001 January 1, 2021 S0 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS SCOPE, INDEX, & CERTIFICATION Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane NorthSuite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 DRAWING USE GUIDELINES AND LIMITATIONS THE CONTRACTOR LISTED IN THE TITLE BLOCK BELOW IS LICENSED BY THE HANSON GROUP TO USE THIS PACKET WITHIN THESE LIMITATIONS NOTED FOR PROJECTS WHICH THE LICENSEE IS DIRECTLY RESPONSIBLE. THE LICENSEE MAY RELEASE THIS PACKET TO ITS SUB-CONTRACTORS AND CLIENTS FOR USE IN THE PROCUREMENT OF BUILDING PERMITS FOR PROJECTS WHICH THE LICENSEE IS USING THESE DRAWINGS. THE FOUNDATION GUIDELINES ARE TO BE ISSUED TO THE APPROPRIATE BUILDING DEPARTMENT IN ACCORDANCE WITH THEIR APPROVED PROCEDURE FOR USE BY THE BUILDING AGENCY DURING PLAN REVIEW AND INSPECTIONS. LIMITATIONS 1. BASEMENT FOUNDATION WALLS TEN FOOT OR LESS IN CLEAR HEIGHT (FROM TOP OF FLOOR SLAB TO TOP OF CONCRETE WALL AT SILL PLATE BEARING-NOT NECESSARILY BASEMENT CEILING HEIGHT). 2. STRUCTURE HEIGHT IS NOT TO EXCEED TWO STORIES ABOVE THE BASEMENT. 3. OVERALL BUILDING IS ASSUMED TO FALL WITHIN THE PRESCRIPTIVE LIMITATIONS OF THE CODE. A SITE SPECIFIC PLAN REVIEW HAS NOT BEEN PERFORMED. 4. STRUCTURES CONSTRUCTED OF WOOD FLOOR, WOOD ROOF, AND WOOD WALLS ONLY. NO PRECAST OR STRUCTURAL CONCRETE BEARING ON FOUNDATION WALLS IS PERMITTED. 5. EXTERIOR GRADE SLOPING DOWN AND AWAY FROM THE FOUNDATION WALLS. 6. ANY CASE BEYOND THE ABOVE NOTED ITEMS REQUIRES SEPARATE AND SPECIFIC STRUCTURAL ENGINEERING DOCUMENTS. COLD WEATHER GUIDELINES: 1. THE CONTRACTOR AND CONCRETE SUPPLIER ARE TO WORK TO OBTAIN A MIX DESIGN WHICH WILL ADEQUATELY PERFORM UNDER THE EXPECTED CONSTRUCTION CONDITIONS. THE USE OF ADDITIONAL CEMENT, HIGH-EARLY STRENGTH CONCRETE, AND/OR ACCELERATOR IS RECOMMENDED AT TEMPERATURES AND CONDITIONS EXPECTED LESS THAN TWENTY DEGREES F. 2. DELIVER CONCRETE WARM AND IN A TIMELY MANNER. PLACE CONCRETE EARLY IN THE DAY WHEN POSSIBLE. 3. DO NOT ADD ADDITIONAL WATER TO THE CONCRETE. THE USE OF WATER REDUCING AGENTS IS RECOMMENDED WHEN WORKABILITY CONCERNS EXIST. NO CONCRETE IS TO BE PLACED ON SNOW OR IN CONTACT WITH FROZEN MATERIALS. 4. REBAR DOES NOT NEED TO BE PRE-HEATED, BUT IS TO BE FREE OF FROST, SNOW, AND ICE. 5. BLANKETS OR OTHER ACCEPTED PROTECTION IS HIGHLY RECOMMENDED FOR THE TOP 24" OF THE WALLS WHEN THE AIR TEMPERATURE IS LESS THAN TEN DEGREES F AND FOR THE FULL HEIGHT OF THE WALL WHEN THE AIR TEMPERATURE IS LESS THAN ZERO DEGREES F. **THE ABOVE COLD WEATHER GUIDELINES ARE GENERAL RECOMMENDATIONS AND ALL ACI COLD WEATHER REQUIREMENTS ARE TO BE FOLLOWED AT THE RESPONSIBILITY OF THE LICENSEE. MATERIALS CONCRETE WALLS: F'c = 3000 PSI @ 28 DAYS MIX DESIGN AND PROPORTIONED BY CONCRETE SUPPLIER CONCRETE FOOTINGS: F'c = 5000 PSI @ 28 DAYS (OR 3000 PSI WITH AN APPROVED ADMIXTURE THAT PROVIDES A WATER AND VAPOR RESISTANCE AT LEAST OR EQUIVALENT TO 5000 PSI CONCRETE. AGGREGATE: FOOTINGS - 1 12" MAX. WALLS/SLABS - 34" MAX. REINFORCING STEEL: #4- BARS - ASTM A615 GRADE 40 #5+ BARS - ASTM A615 GRADE 60 TREATED SILL PLATE: SYP GRADE #2 OR BETTER ALLOWABLE SOIL BEARING PRESSURE 1,500 PSF MINIMUM EQUIVALENT REBAR TABLE FOR BUNDLED HORIZONTAL BARS (2)#4 = (1)#6 (3)#4 = (2)#5 (3)#5 = (2)#6 COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 151 1.001 January 1, 2021 S1 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS DRAWING LIMITATIONS & MATERIALS Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane NorthSuite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 GENERAL NOTES 1. DO NOT BACKFILL BASEMENT WALLS UNTIL THE CONCRETE HAS REACHED A MINIMUM COMPRESSIVE STRENGTH OF 2,250 PSI. IN ADDITION, DO NOT BACKFILL UNTIL THE BASEMENT WALLS ARE LATERALLY SUPPORTED BY THE FINAL INSTALLED FLOOR CONSTRUCTION AT THE TOP AND BOTTOM, UNLESS ADEQUATE SHORING IS INSTALLED AS REQUIRED. SHORING IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 2. STRIP FOOTING MAY BE PLACED AT ELEVATIONS LOWER THAN SHOWN IN THE DETAILS. 3. 1 12" DEEP BY 312" WIDE BY CONTINUOUS KEYWAYS MAY BE USED IN LIEU OF DOWELS FOR FULL HEIGHT ANDFROST WALLS. 4. STRIP FOOTING TO WALL CENTERLINES MAY BE OFFSET UP TO 2", HOWEVER, A MINIMUM OF 2" OF STRIP FOOTING IS TO EXTEND BEYOND THE WALL FACE ON EACH SIDE. 5. PROVIDE CODE REQUIRED FROST PROTECTION TO THE BOTTOM OF ALL FOOTINGS. 6. SLOPE GRADE DOWN AND AWAY FROM THE STRUCTURE A MINIMUM OF 6" WITHIN THE FIRST TEN FEET UNLESS ADEQUATE DRAINAGE OR SWALES ARE PROVIDED. 7. BOTH MATERIALS AND INSTALLATION OF DRAIN TILE, WATER-PROOFING, CONTROL JOINTS, FLASHING, AND INSULATION ARE TO BE IN ACCORDANCE WITH THE CODE BY THE GENERAL CONTRACTOR, UNLESS NOTED OTHERWISE. 8. ALL WALL WIDTHS SHOWN ARE NOMINAL DIMENSIONS, UNLESS NOTED OTHERWISE. OVERALL WALL THICKNESS MAY VARY BY UP TO 12" FROM THAT SHOWN ON THE DRAWINGS. 9. REINFORCING PLACEMENT TOLERANCE IS NOT TO EXCEED 12". BARS BEING SPLICED ARE TO BE WITHIN 2"OF CENTERLINE. MINIMUM SPLICE LENGTHS ARE 30 BAR DIAMETERS FOR GRADE 40 STEEL AND 48 BAR DIAMETERS FOR GRADE 60 STEEL. TYING IS NOT REQUIRED PROVIDED THESE TOLERANCES ARE MET. 10.PROVIDE MATCHING HOOK BARS FOR ALL HORIZONTAL BARS AT WALL CORNERS AND INTERSECTIONS. HORIZONTAL BARS MAY BE PLACED ANYWHERE WITHIN THE WALL AS LONG AS A 2" MINIMUM CLEAR COVER IS ACHIEVED ON ALL SIDES. 11.REINFORCING MAY BE BUNDLED UP TO A MAXIMUM OF THREE BARS. 12.DOWELS MAY BE DRILLED AND GROUTED IN PLACE. VERTICAL BARS AND DOWELS DO NOT NEED TO ALIGN. VERTICAL BARS MAY BE DRILLED AND EMBEDDED 5" INTO THE STRIP FOOTING IN LIEU OF DOWELS. 13.THE BOND BETWEEN CONCRETE AND REINFORCING WILL NOT BE APPRECIABLY REDUCED IF VERY MINOR FORM OIL IS PRESENT FOR THE CONDITIONS CONTAINED WITHIN THESE DRAWINGS. 14.SILL PLATES ARE TO BE ANCHORED WITH A MINIMUM OF TWO ANCHORS PER SILL SECTION. ALL SECTIONS ARE TO HAVE AN ANCHOR WITHIN 4" TO 12" OF EACH END. AN ANCHOR IS TO BE PLACED AT ALL WALL CORNERS AND INTERSECTIONS ON WALLS MORE THAN TWO FEET IN LENGTH. WALLS TWO FEET OR LESS IN LENGTH REQUIRE A MINIMUM OF ONE ANCHOR. REQUIREMENTS FOR SHEAR WALLS AND BRACED PANELS MAY BE IN EXCESS OF THESE REQUIREMENTS. TWO INCH WASHERS ARE ONLY REQUIRED AT FULL HEIGHT FOUNDATION WALLS. BUILDING DESIGNER IS TO ACCOMMODATE LOAD PATH FOR ANY VERTICAL LOAD TRANSFER OVER A SILL PLATE OVERHANG CONDITION. 15.ANCHOR BOLTS 12" DIAMETER OR LARGER ARE NOT REQUIRED TO BE CORROSION PROTECTED IN ACCORDANCE WITH CODE SECTION R317.3.1 EXCEPTION 1. 16.ALL PRE-MANUFACTURED FASTENERS AND CONNECTORS ARE TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS. 17.FLOOR BLOCKING IS ONLY REQUIRED AT FULL HEIGHT FIRST FLOOR NON-BEARING FOUNDATION WALLS. 18.CARE IS TO BE TAKEN DURING CONCRETE PLACEMENT TO MINIMIZE INADEQUATE HORIZONTAL AND DIAGONAL COLD JOINTS, AND TO PREVENT THESE JOINTS ENTIRELY IN WALLS WITHOUT VERTICAL REINFORCEMENT. ADEQUATELY VIBRATE CONCRETE AT POTENTIAL JOINT LOCATIONS AS REQUIRED, BASED ON PLACEMENT CONDITIONS TO ELIMINATE HONEYCOMBING AND TO ENSURE SUFFICIENT BONDING IS ACHIEVED. 19.TOP AND BOTTOM OF FOUNDATION WALLS ARE TO BE LATERALLY SUPPORTED PRIOR TO BACKFILLING. MEANS AND METHODS OF LATERAL SUPPORT ARE BY OTHERS. COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 152 1.001 January 1, 2021 S2 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS GENERAL NOTES Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 (2) #4 HORIZONTAL BARS BOTH TOP & BOTTOM EXTENDED AT LEAST 24" BEYOND EACH END OF STEP STABLE BANK HIGH FOOTING MAY BE EXTENDED PROVIDED BARS ARE PLACED AS SHOWN HORIZ. BARS TOP & BOTTOM 6" MIN THICK CONCRETE FOUNDATION, SEE OTHER DETAILS FOR MORE INFO OPTIONAL CONTROL JOINT AT EACH END OF STEP 72" MAX SPAN EQ.EQ.24" MINDETAIL B 3" MIN TYPCONCRETE STRIP FOOTING 11B DETAIL A 36" MIN STEP 2 x STEP STEPNOTE: DO NOT LOCATE CONCENTRATED LOADS IN EXCESS OF 2,000 PLF OR 10,000 POUNDS ABOVE STEP LOCATIONS SHOWN REAR FROST WALL LOOKOUT WALL FULL HEIGHT WALL GARAGE FROST WALL ELEVATION SHOWN FOR REPRESENTATION PURPOSES ONLY -MAY NOT APPLYELEVATION STEP SPACING REQUIREMENTS A TYP. COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 153 1.001 January 1, 2021 S3 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS STEP FOOTING DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6" MIN. WOOD FRAMING ABOVE BY OTHERS 12"Ø x 10" LONG ANCHOR BOLTS (7" MIN. EMBED) @ 72" O.C. MAX. OR EQUIVALENT METAL STRAP ANCHORS SLOPE GRADE AWAY FROM FOUNDATION OPTIONAL STEM WALL MINIMUM THICKNESS TO MATCH SILL PLATE SILL PLATE TO MATCH FRAME WALL ABOVE 16" MAX FOR 4" THICK STEM 24" MAX. FOR 6" THICK STEM SLAB-ON-GRADE BY OTHERS (1) #4 x CONTINUOUS HORIZONTAL BAR AT TOP OF WALL 6" MIN. C.I.P. CONCRETE FOUNDATION WALL UNREINFORCED CONCRETE STRIP FOOTING SEE S7 #4x2'-0" DOWELS @ 72" O.C. MAX (5" MIN. EMBED) DOWELS ARE NOT REQUIRED IF BACKFILL IS PLACED EQUALLY ON BOTH SIDES IN LIFTS NOT TO EXCEED 24"-ALTERNATE EACH SIDE COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 154 1.001 January 1, 2021 S4 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS WALKOUT WALL DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6" MIN.3'-0" MAX GRADE HEIGHTABOVE TOP OF SLAB#4 x 2'-0" DOWELS (5" MIN. EMBED) CENTERED IN WALL @ 48" O.C. (SAND SOIL) OR 36" O.C. (SANDY-CLAY SOIL) OR 24" O.C. (CLAY SOIL) DOWELS MUST BE WET SET OR DRILLED AND EPOXY GROUTED 6" MIN. THICK C.I.P. CONCRETE FOUNDATION WALL SLOPE GRADE AWAY FROM FOUNDATION 12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED) @ 72" O.C. MAX. OR EQUIVALENT METAL STRAP ANCHORS (1) #4 x CONT HORIZONTAL BAR AT TOP OF WALL FRAMING & SILL PLATE BY OTHERS SLAB-ON-GRADE BY OTHERS UNREINFORCED CONCRETE STRIP FOOTING SEE S7 (18" MIN WIDTH FOR CLAY BACKFILL OR 16" MIN WIDTH IF 2'-6" MAX UNBALANCED BACKFILL) COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 155 1.001 January 1, 2021 S5 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS LOOKOUT/KNEE WALL DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6'-0" MAXWOOD FRAMING ABOVE BY OTHERS 12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED) @ 72" O.C. MAX. OR EQUIVALENT METAL STRAP ANCHORS SLOPE GRADE AWAY FROM FOUNDATION AT A GRADUAL 2% SLOPE PER GENERAL NOTE 6 SILL PLATE TO MATCH FRAME WALL ABOVE #4 x CONTINUOUS HORIZONTAL BARS @ 24" O.C. TYP. OPTIONAL 2" RIGID INSULATION ON INSIDE FACE AND UNDER SLAB-ON-GRADE FOR 24" MIN. UNREINFORCED CONCRETE STRIP FOOTING SEE S7 (DROP FOR FROST AS REQUIRED PER SITE DESIGN) #4x2'-0" DOWELS @ 48" O.C. MAX (5" MIN. EMBED) (1) #4 x CONTINUOUS HORIZONTAL BAR AT TOP OF WALL OPTIONAL SLAB LEDGE CONCRETE SLAB-ON-GRADE 8" MIN. C.I.P. CONCRETE FOUNDATION WALL #4x4'-0" HOOKS @ 24" O.C. BENT OR DRILLED AND EPOXY GROUTED 3'-0"1'-0"NO HOOKS @ 3'-0" OR LESSGRANULAR MATERIAL (SAND) DETAIL ABOVE MAY ONLY BE UTILIZED FOR A LENGTH OF 15'-0" #5 VERTICAL BARS @ 24" O.C. CENTERED IN WALL TO AID IN THE REDUCTION OF CRACKING AND BACKFILLING ISSUES PRIOR TO TOP OF WALL PINNING CONTRACTOR IS TO PROVIDE TEMPORARY TOP OF WALL BRACING UNTIL GARAGE SLAB-ON-GRADE IS IN PLACE (HOOKS INTO GARAGE SLAB PROVIDE REQUIRED TOP OF WALL LATERAL SUPPORT) COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 156 1.001 January 1, 2021 S6 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS UNBALANCED FOUNDATION DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6" MIN. CLEAR HEIGHTBACKFILL HEIGHT112" CLEAR UNREINFORCED CONCRETE STRIP FOOTING PER CODE OR BY BUILDING DESIGNER, AS AN ALTERNATIVE GUIDE USE TABLE SHOWN BELOW 8" MIN. C.I.P. CONCRETE FOUNDATION WALL-SEE REBAR TABLE S8 FOR VERTICAL REBAR ANCHOR BOLTS SEE WALL ANCHOR INFO ON S11 FLOOR TO SILL CONNECTION SEE S10 WOOD FLOOR SYSTEM BY OTHERS SLOPE GRADE AWAY FROM FOUNDATION 2x6 MIN SILL PLATE CLEAR HEIGHT OF 8'-0" OR LESS (2)#4xCONT. HORIZONTAL BARS CLEAR HEIGHT OF 8'-0" OR MORE (3)#4xCONT. HORIZONTAL BARS CONCRETE SLAB-ON-GRADE PLACED TIGHT TO FOUNDATION WALL #4x2'-0" DOWELS @ 72" O.C. MAX (5" MIN. EMBED) GENERAL STRIP FOOTING SIZE GUIDE SOIL ONE-STORY STRUCTURE TWO-STORY STRUCTURE 2000 PSF 16" WIDE x 8" THICK 20" WIDE x 8" THICK 1500 PSF 20" WIDE x 8" THICK 26" WIDE x 8" THICK THIS TABLE IS A GENERAL FOOTING SIZE GUIDE FOR TRIBUTARY UNIFORM LOADING ONLY BASED ON MAXIMUM 25'-0" FLOOR SPANS & 50'-0" ROOF SPANS AND IS TO BE VERIFIED BY HOME DESIGNER. FURTHER CONSIDERATION IS TO BE TAKEN BY HOME DESIGNER FOR VENEER WEIGHT, WALL THICKNESSES OVER 10", AND FLOOR AND ROOF DEAD LOADS OVER 15 PSF. CONCENTRATED LOADS FROM GIRDER TRUSSES, BEAMS, HEADERS, ETC. ARE TO BE ACCOUNTED FOR AND SIZED INDEPENDENTLY OF THIS GUIDE BY OTHERS. COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 157 1.001 January 1, 2021 S7 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS BASEMENT WALL DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 GRADE 60 #6 VERTICAL BAR SPACING FOR FULL HEIGHT WALLS w/ F'c = 3000 PSIALTERNATIVE TO CODE TABLE R404.1.2EQUIVALENT VERTICAL REBARSUBSTITUTION TABLEBACKFILL TYPECLEAR HEIGHT(SEE S7)BACKFILL HEIGHT(SEE S7)8'-0"9'-0"10'-0"7'-6"7'-0" OR LESS8'-6"8'-0"7'-0"6'-0" OR LESS9'-6"9'-0"8'-0"7'-0"6'-0" OR LESS8"10" 12"8"10" 12"8"10" 12"NONE NONE NONENONE NONENONE NONENONE NONENONENONENONENONENONENONENONENONE NONENONE NONENONENONENONENONENONENONENONENONENONENONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONE* = NONE IF F'c = 4,000 PSI*36"*36"*36"*36"*36"*36"36"36"36"36"36"36"36"36"24"24" 24"24"SAND (30 PSF/FT)WALL THICKNESSSANDY CLAY (45 PSF/FT)WALL THICKNESSCLAY (60 PSF/FT)WALL THICKNESS#6 @ 24" = #5 @ 18" = #4 @ 12" (GRADE 60) = #4 @ 8" (GRADE 40)(1)#6 = (2)#4 (GRADE 60)#6 @ 36" = #5 @ 24" = #4 @ 18" (GRADE 60) = #4 @ 12" (GRADE 40) COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 158 1.001 January 1, 2021 S8 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS VERTICAL REINFORCING TABLE Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 VENEER OR SLAB-ON-GRADE BY OTHERS FOUNDATION WALL SEE S7 WOOD FLOOR SYSTEM BY OTHERS FRAMING BY OTHERS 16" HIGH MAX x 6" THICK MIN STEM6"MINWOOD FLOOR SYSTEM BY OTHERS FRAMING BY OTHERS 6" MIN THICK STEM #4 DOWELS @ 36" O.C. EMBEDDED 24" INTO LOWER WALL FOUNDATION WALL SEE S7 VENEER OR SLAB-ON-GRADE BY OTHERS 12"VENEER OR SLAB-ON-GRADE BY OTHERS FOUNDATION WALL SEE S4 OR S5 FRAMING BY OTHERS 16" HIGH MAX x 4" THICK MIN STEM THICKNESS TO MATCH SILL PLATE6"3'-0" MAXVENEER OR SLAB-ON-GRADE BY OTHERS FOUNDATION WALL SEE S6 SLAB-ON-GRADE FRAMING BY OTHERS 6" MIN THICK STEM DETAIL @ HIGH GRADE SIM @ NON-BEARING DETAIL @ LOOKOUT SIM @ FROST WALL DETAIL @ FROST WALLS w/ LOW GRADE DETAIL @ LOW GRADE SIM @ NON-BEARING 112" CLEAR MINMAX#4 DOWELS @ 36" O.C. EMBEDDED 24" INTO LOWER WALL (CENTER IN STEMWALL) SLOPE GRADE AWAY FROM FOUNDATION SLOPE GRADE AWAY FROM FOUNDATION SLOPE GRADE AWAY FROM FOUNDATION SLOPE GRADE AWAY FROM FOUNDATION NOTE: INCREASE STRIP FOOTING WIDTH AT ALL WALLS SUPPORTING MORE THAN 6'-0" OF VENEER. WIDTH TO INCREASE BY THICKNESS OF VENEER MULTIPLIED BY NUMBER OF STORIES. COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 159 1.001 January 1, 2021 S9 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS BRICK LEDGE DETAILS Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6"12"Ø ANCHOR BOLTS w/ NUT & 18" THICK x 2"Ø OR SQUARE WASHER SEE S11 FOR SPACING (7" EMBED MIN) -METAL STRAP ANCHORS TO BE INSTALLED AT MANUFACTURER EQUIVALENT SPACING FLOOR SYSTEM, TYPE, SIZE, AND SPACING TO BE DETERMINED BY OTHERS RIM BOARD OR BRACING MATERIAL BY OTHERS 2x6 SILL PLATE MINIMUM FLOOR TO SILL CONNECTION AT EACH MEMBER SEE TABLE BELOW WASHER TO BE COUNTERSUNK FLUSH w/ TOP OF SILL PLATE SEE FULL HEIGHT WALL SECTION ON S7 FOR FOUNDATION WALL REQUIREMENTS SLOPE GRADE AWAY FROM FOUNDATION MINTRUSS/JOIST CONNECTION FOR FULL HEIGHT WALLS**** BACKFILL TYPECLEAR HEIGHT (SEE S7) FLOOR MEMBER SPACING 8'-0" 9'-0" 10'-0" 16" 19.2" A (4) 0.131"Ø x 3" TOP NAILS AT EACH MEMBER SAND (30 PSF/FT) SANDY CLAY (45 PSF/FT) CLAY (60 PSF/FT) 24" 16" 19.2" 24" 16" 19.2" 24" A A A A A A A B A A B B B B B C C C D D D D D D D C CONNECTION A (4) 0.148"Ø x 3" TOP NAILS AT EACH MEMBERCONNECTION B (2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON A35/USP MPA1 OR USP LJC AT EACH MEMBER CONNECTION C CONNECTION D (2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON FWANZ* OR USP LJQ** OR (2) SIMPSON A35s***/(2) USP MPA1s*** AT EACH MEMBER * FWANZ TO BE USED WITH A MIN. 118" OSB RIM AND LOCATED w/IN 5" OF EACH MEMBER. WITH FLOOR TRUSSES, FWANZ MUST BE IN CONTACT WITH A TRUSS OR A MINIMUM 2x4 CONTINUOUS BOTTOM BRACE MUST BE IN PLACE. ** LJQ IS TO BE APPROPRIATELY SIZED BASED ON MEMBER WIDTH. *** MEMBER MUST BE A MINIMUM OF 3" WIDE FOR PLACEMENT OF (2) SIMPSON A35s/(2) USP MPA1s. ****CONNECTIONS ARE CLASSIFIED A TO D, WITH D BEING THE STRONGEST. IT IS ACCEPTABLE TO USE A STRONGER CLASS CONNECTION THAN NOTED IN THE TABLE ABOVE. 2x8 SILL PLATE TO BE USED w/ MAXIMUM OF 112" OVERHANG (MAINTAIN 234" EDGE DISTANCE TO BOTH CONCRETE AND INSIDE OF SILL PLATE) - VERTICAL LOAD TRANSFER BY SUPPLIER COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 1510 1.001 January 1, 2021 S10 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS FLOOR BEARING CONNECTIONS Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 12"Ø ANCHOR BOLT AND NON-BEARING WALL BLOCKING SPACING FOR FULL HEIGHT WALLS* ALTERNATIVE TO CODE TABLE R404.1.(1) BACKFILL TYPE CLEAR HEIGHT (SEE S7) BACKFILL HEIGHT (SEE S7) 8'-0" 9'-0" 10'-0" 7'-6" 7'-0" 8'-6" 8'-0" 7'-0" OR LESS 9'-6" 9'-0" 8'-0" 7'-0" OR LESS 72" * 12"Ø EPOXIED THREADED ROD w/ 6" EMBED MAY BE USED AT SPACING SHOWN SAND (30 PSF/FT)SANDY CLAY (45 PSF/FT) CLAY (60 PSF/FT) 6'-0" OR LESS 72" 72" 72" 72" 72" 72" 72" 72" 72" 72" 72" 72" 48" 60" 72" 48" 60" 72" 36" 48" 72" 36" 36" 72" 72"72" 48" 24" 24" ALTERNATIVE ANCHOR SPACING FOR FULL HEIGHT WALLS** ALTERNATIVE TO CODE TABLE R404.1.(1) BACKFILL TYPECLEAR HEIGHT (SEE S7) BACKFILL HEIGHT (SEE S7) 8'-0" 9'-0" 10'-0" 7'-6" 7'-0" 8'-6" 8'-0" 7'-0" OR LESS 9'-6" 9'-0" 8'-0" 7'-0" OR LESS 48" ** APPLIES TO MAB 15/FA1, MAB23/FA2, MAS/FA3, 12"Ø EXPANSION BOLT w/ 6" EMBED, 12"Ø SELF-CUTTING ANCHOR BOLT w/ 4" EMBED, OR SIMPSON FWAZ ANCHOR SAND (30 PSF/FT) SANDY CLAY (45 PSF/FT) CLAY (60 PSF/FT) 6'-0" OR LESS 60" 72" 30" 36" 72" 18" 24" 42" 72" 72" 24" 18" 20" 24" 18" 24" 24" 30" 42" 16" 12" 14" 16" 12" 16" 36" 36" N/A N/A COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 1511 1.001 January 1, 2021 S11 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS ANCHOR SPACING TABLES Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 NAIL SHEATHING TO BLOCKING/JOISTS0.131 Ø x 3" LONG NAILS @ 6" O.C.STRUCTURAL RIM BOARD BY OTHERSTYPE D CONNECTOR @ BLOCKING SEES102 x 6 MINSILL PLATEFOUNDATION WALL SEE OTHER SHEETSFOR ANCHORS & WALL INFOSLOPE GRADE AWAY FROMFOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MINSPACERS UNTIL SPACES IN WHICH FULLHEIGHT BLOCKING CAN BE INSTALLED,TOE NAIL TO FLOOR MEMBERS EACH ENDw/ (12) 0.131"Øx3" LONG NAILSFRAMINGBY OTHERSOPTIONAL OPEN SPACE AS SHOWN ORSHIFT FULL HEIGHT BLOCKINGPROVIDE BLOCKINGAS REQUIRED TO ACHIEVENAILING SHOWN. (MIN 2SPACES) BLOCKING HEIGHTTO MATCH JOIST DEPTH &BE OF LUMBER, I-JOIST, OROTHER MANUFACTUREDMATERIAL ATTACHBLOCKING TO JOISTS w/ TOENAILS EACH ENDJOISTS BY OTHERSSEE S11 FOR SPACING OFBLOCKING SYSTEM SHOWNNOTES:1. MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x3" LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2. NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3. BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTHMEMBER BLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD.NAILING SHOWN IS TO BE USED AT MINIMUM.4. BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5. HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE. COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 1512 1.001 January 1, 2021 S12 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS NON BEARING JOIST BLOCKING DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 NAIL SHEATHING TO BLOCKING/TRUSSESw/ (12) 0.131"Øx3" LONG NAILSDUCT/MECHANICAL (AS REQUIRED)BY OTHERSFRAMINGBY OTHERS0.131 Ø x 3" LONGNAILS @ 6" O.C.RIM TRUSSBY OTHERSTOP NAIL RIM TO SILLw/ MIN OF (12)0.131 Ø x3" LONG NAILS EACHSIDE OF BLOCKING ORTYPE D CONNECTOR @BLOCKING SEE S102 x 6 MINSILL PLATEFOUNDATION WALL SEEOTHER SHEETS FORANCHORS & WALL INFOSLOPE GRADE AWAY FROMFOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MIN SPACERSTOP & BOTTOM AT MECHANICAL UNTILSPACES IN WHICH BLOCKING CAN BEINSTALLED, TOE NAIL TO FLOOR MEMBERSw/ (2) 0.131 Ø x 3" LONG NAILS3/4" PLYWOOD/OSB ONE SIDEOF BLOCKING w/ (6) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMOR 1/2" PLYWOOD/OSB EACHSIDE OF BLOCKING EACH w/(4) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMPROVIDE 2 x 4 MIN BLOCKINGTOP & BOTTOM OF TRUSSESAS REQUIRED TO ACHIEVENAILING SHOWN.INSTALL w/ (2) 0.131 Ø x 3"LONG TOE NAILSTRUSSES BY OTHERSNOTES:1. MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x 3"LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2. NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3. BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTH MEMBERBLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD. NAILING SHOWN IS TOBE USED AT MINIMUM.4. BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5. HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE.SEE S11 FOR SPACING OFBLOCKING SYSTEM SHOWN COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 1513 1.001 January 1, 2021 S13 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS NON-BEARING TRUSS BLOCKING DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 10'-0" MAX3'-8" MAX2'-6" MIN OPENING1'-6" MIN3'-0" EACH WAY MIN 112" TYPSLOPE GRADE AWAY FROM FOUNDATION #4 HORIZONTAL BARS @ 12" O.C. CENTERED IN WALLS LAP AROUND CORNERS AND HOOK INTO FOUNDATION WALL @ EACH SIDE (REFER TO S7 FOR HORZ. BAR REQUIREMENTS w/ 8" C.I.P. WALLS) 6" MIN C.I.P. CONCRETE WALL #4 VERTICAL BARS @ EACH OUTSIDE CORNER OF WELL (1)#4 x2'-0" DOWEL @ EACH OUTSIDE CORNER OF WELL (5" MIN EMBED) 12" WIDE x 8" THICK MIN STRIP FOOTING (1) #4 HORIZONTAL BAR AT TOP OF WALL (2) #4 HORIZONTAL BARS TOP & BOTTOM OF LINTEL EXTEND 24" MIN PAST OPENING EACH END (WOOD OR STEEL OPTION BY OTHERS) WALL BEYOND PLACE (2) #4 VERTICAL BARS FULL HEIGHT AND ONE ANCHOR w/IN 12" OF OPENING EACH END 8" MIN C.I.P. CONCRETE WALL SLAB-ON-GRADE UNREINFORCED CONCRETE STRIP FOOTING SEE FULL HEIGHT WALL SECTION S7 LOOKOUT WALL SEE S5 GRANULAR MATERIAL (SAND) SLOPE WINDOW WELL LADDER/ ESCAPE MEANS BY OTHERS 5'-0" EACH WAY MAX FLOOR SYSTEM BY OTHERS (DO NOT PLACE GIRDERS OR BEAMS OVER CONCRETE LINTEL DESIGNED FOR 1500 PLF)IF CONCRETEOPTIONAL RIGID INSULATION w/IN WINDOW WELL AT THE DISCRETION OF THE BUILDER FOR ADDITIONAL FROST PROTECTION AS REQUIRED PER SITE DESIGN 6" MIN. COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 1514 1.001 January 1, 2021 S14 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS WINDOW WELL DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6'-0" MAX. 8" MIN. GRAD E L I N E 9'-4" MAX.6'-0" MAX.4'-0" MAX.SEE BASEMENT WALL DETAILSEE LOOKOUT WALL DETAILSIM.CONSTRUCT SIM. LOOKOUT WALLw/ MIN. (2) #4 HORIZ. BARS3 MIN. 1 S7S5S5SLAB-ON-GRADE BEYOND CONCRETE STRIP FOOTING STEP DOWN AS REQ'D FOR FROST PROTECTION AT NON-BEARING WALLS, LOCATE BLOCKING DETAILS (S12 / S13) AT END OF FULL HEIGHT WALL PROVIDE (2) ADDITIONAL #4 BARS @ END OF FULL HEIGHT WALL SEGMENT LOCATED 2" FROM INSIDE WALL FACE FLOOR FRAMING ABOVE BY OTHERS INFILL WOOD FRAMING BY OTHERS COPYRIGHT HANSON GROUP LLC 2021© City: ofSheet: Drawing Date: Project Number: 1515 1.001 January 1, 2021 S15 Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com 2021 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS STEPPING DOWN WALL WITH GRADE    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 5350 178th St W., Lakeville HVAC Load Calculations for Country Joe Homes 22260 Dodd Blvd Lakeville, MN 55044 Prepared By: Jake Ryan Silver Tree Plumbing & Heating 1335 Mendota Heights Rd Mendota Heights, MN 55120 651-900-7053 Tuesday, May 31, 2022 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 5350 178th St W., Lakeville Eagan, MN 55121 Page 2 Project Report General Project Information Project Title:5350 178th St W., Lakeville Designed By:Jake Ryan Project Date:5/31/2022 Project Comment: Client Name:Country Joe Homes Client Address:22260 Dodd Blvd Client City:Lakeville, MN 55044 Client Phone:(952) 469-4066 Company Name:Silver Tree Plumbing & Heating Company Representative:Jake Ryan Company Address:1335 Mendota Heights Rd Company City:Mendota Heights, MN 55120 Company Phone:651-900-7053 Company E-Mail Address:jaker@silvertreepandh.com Design Data Reference City:Minneapolis, Minnesota Building Orientation:Front door faces North Daily Temperature Range:Medium Latitude:44 Degrees Elevation:834 ft. Altitude Factor:0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter:-15 -15.33 n/a 30%72 33.90 Summer:88 73 50%50%72 42 Check Figures Total Building Supply CFM:837 CFM Per Square ft.:0.274 Square ft. of Room Area:3,056 Square ft. Per Ton:1,453 Volume (ft³):23,368 Building Loads Total Heating Required Including Ventilation Air:39,474 Btuh 39.474 MBH Total Sensible Gain:18,723 Btuh 74 % Total Latent Gain:6,508 Btuh 26 % Total Cooling Required Including Ventilation Air:25,231 Btuh 2.10 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. F:\ ...\5350 178th S ... eat Calc.rh9 Tuesday, May 31, 2022, 12:30 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 5350 178th St W., Lakeville Eagan, MN 55121 Page 3 Load Preview Report Scope Has AED Net Ton ft.² /Ton Area Sen Gain Lat Gain Net Gain Sen Loss Min Htg CFM Min Clg CFM Sys Htg CFM Sys Clg CFM Sys Act CFM Duct Size Building 2.10 1,453 3,056 18,723 6,508 25,231 39,474 458 837 458 837 837 System 1 Main Floor No 2.10 1,453 3,056 18,723 6,508 25,231 39,474 458 837 458 837 837 11x15 Ventilation 857 4,177 5,033 5,222 Humidification 5,344 Zone 1 3,056 17,867 2,331 20,198 28,908 458 837 458 837 837 11x15 1-Basement 1,288 3,264 0 3,264 10,219 162 153 162 153 153 2--5 2-Upper Level 1,288 12,082 2,331 14,413 12,129 192 566 192 566 566 5--6 3-Crawl Space 240 39 0 39 1,376 22 2 22 2 2 1--1 4-Mud Room/Laundry 240 2,481 0 2,481 5,184 82 116 82 116 116 1--6 F:\ ...\5350 178th S ... eat Calc.rh9 Tuesday, May 31, 2022, 12:30 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 5350 178th St W., Lakeville Eagan, MN 55121 Page 4 Duct Size Preview Room or Duct Name Source Minimum Velocity Maximum Velocity Rough. Factor Design L/100 SP Loss Duct Velocity Duct Length Htg Flow Clg Flow Act. Flow Duct Size System 1 Supply Runouts Zone 1 1-Basement Built-In 450 750 0.01 0.1 560.7 162 153 153 2--5 2-Upper Level Built-In 450 750 0.01 0.1 576.6 192 566 566 5--6 3-Crawl Space Built-In 450 750 0.01 0.1 338.4 22 2 2 1--1 4-Mud Room/Laundry Built-In 450 750 0.01 0.1 592.1 82 116 116 1--6 Other Ducts in System 1 Supply Main Trunk Built-In 650 900 0.003 0.1 730.5 458 837 837 11x15 SummarySummarySummarySummarySummarySummarySummarySummary System 1 Heating Flow:458 Cooling Flow:837 F:\ ...\5350 178th S ... eat Calc.rh9 Tuesday, May 31, 2022, 12:30 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 5350 178th St W., Lakeville Eagan, MN 55121 Page 5 Total Building Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain LOWEE BUILDER GRADE: Glazing-LOWEE BUILDER GRADE, ground reflectance = 0.23, indoor insect screen with 100% coverage, U-value 0.32, SHGC 0.32 264.8 7,372 0 5,030 5,030 11G: Door-Wood - Panel, U-value 0.54 20 940 0 292 292 11J: Door-Metal - Fiberglass Core, U-value 0.6 17.8 928 0 288 288 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs, U-value 0.065 1888 10,678 0 1,997 1,997 15B0-10sf-4: Wall-Basement, , R-10 board insulation to floor, no interior finish, 4' floor depth, U-value 0.054 413 1,940 0 0 0 RJ R-20: Wall-Frame, Custom, RJ R-20 RIM JOIST R20 SPRAY FOAM, U-value 0.05 131.2 570 0 136 136 R49 Attic: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Custom, R49 Attic, U-value 0.02 1288 2,241 0 1,829 1,829 17A-12: Roof/Ceiling-Roof Deck (roofing, wood, insulation) or SIP Panels Supported on Beams, Dark or Bold-Color Asphalt Shingle, Dark Metal, Dark Membrane, Dark Tar and Gravel, 1.5" wood plus R- 12 insulation, U-value 0.063 240 1,315 0 650 650 21A-28: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 28' wide, U-value 0.022 1528 2,924 0 0 0 Subtotals for structure:28,908 0 10,222 10,222 People:6 1,200 1,380 2,580 Equipment:1,131 4,262 5,393 Lighting:535 1,824 1,824 Ductwork:0 0 0 0 Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Ventilation: Winter CFM: 152, Summer CFM: 152 5,222 4,177 857 5,033 Humidification (Winter) 14.57 gal/day :5,344 0 0 0 AED Excursion:0 0 179 179 Total Building Load Totals:39,474 6,508 18,723 25,231 Check Figures Total Building Supply CFM:837 CFM Per Square ft.:0.274 Square ft. of Room Area:3,056 Square ft. Per Ton:1,453 Volume (ft³):23,368 Building Loads Total Heating Required Including Ventilation Air:39,474 Btuh 39.474 MBH Total Sensible Gain:18,723 Btuh 74 % Total Latent Gain:6,508 Btuh 26 % Total Cooling Required Including Ventilation Air:25,231 Btuh 2.10 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. F:\ ...\5350 178th S ... eat Calc.rh9 Tuesday, May 31, 2022, 12:30 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 5350 178th St W., Lakeville Eagan, MN 55121 Page 6 Building Rotation Report All rotation degree values in this report are clockwise with respect to the project's original orientation. Building orientation as entered (zero degrees rotation): Front door faces North Individual Rooms Rm. No. Room Name 0° Rot. CFM 45° Rot. CFM 90° Rot. CFM 135° Rot. CFM 180° Rot. CFM 225° Rot. CFM 270° Rot. CFM 315° Rot. CFM High Duct Size System 1: Zone 1: 1 Basement 153 210 *238 194 129 191 229 205 2--6 2 Upper Level 566 642 *669 624 543 606 630 616 6--6 3 Crawl Space 2 2 *2 2 2 2 2 2 1--1 4 Mud Room/Laundry 116 *117 115 116 115 112 108 112 1--6 * Indicates highest CFM of all rotations. Whole Building Rotation Degrees Front door Faces Supply CFM Sensible Gain Latent Gain Net Tons 0°North 837 18,723 *6,508 2.10 45°Northeast 972 21,596 6,508 2.34 90°East *1,024 *22,707 6,508 *2.43 135°Southeast 936 20,836 6,508 2.28 180°South 790 17,711 6,508 2.02 225°Southwest 911 20,307 6,508 2.23 270°West 969 21,547 6,508 2.34 315°Northwest 935 20,822 6,508 2.28 * Indicates highest value of all rotations. 2.0 2.1 2.2 2.3 2.4 North Northeast East Southeast South Southwest West NorthwestCooling TonsDirection Front door Faces Building Rotation Tonnage Building Net Tonnage F:\ ...\5350 178th S ... eat Calc.rh9 Tuesday, May 31, 2022, 12:30 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 5350 178th St W., Lakeville Eagan, MN 55121 Page 7 Building Rotation Report (cont'd) 22,000 23,000 24,000 25,000 26,000 27,000 28,000 29,000 30,000 31,000 32,000 8 am 9 am 10 am 11 am 12 pm 1 pm 2 pm 3 pm 4 pm 5 pm 6 pm 7 pmBuilding Net Gain, BtuhTime of Day Building Rotation Hourly Net Gain Front door faces North Front door faces Northeast Front door faces East Front door faces Southeast Front door faces South Front door faces Southwest Front door faces West Front door faces Northwest F:\ ...\5350 178th S ... eat Calc.rh9 Tuesday, May 31, 2022, 12:30 PM Passive (No Fan) Active (With fan and monitoring device ) Location (or future location) of Fan: Other Please Describe Here Not applicable, all ducts located in conditioned space Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS: Capacity in Gallons: Other, describe: AFUE or HSPF% Cfm's " round duct OR " metal duct Not required per mech. code Passive Low: Other, describe: Low: Location of fan(s), describe: Cfm's " round duct OR " metal duct Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. New Construction Energy Code Compliance Certificate Name of Residential Contractor MN License Number City Mailing Address of the Dwelling or Dwelling Unit Rigid, Extruded PolystyreneHeat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: Combustion Air Select a Type Location of duct or system: Rim Joist (2nd Floor+) Building envelope air tightness: Below Entire Slab Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area THERMAL ENVELOPE Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM Total R-Value of all Types of InsulationType: Check All That Apply Mineral FiberboardInsulation Location Foam, Closed Cell Describe other insulated areas Ceiling, flat Non or Not ApplicableFiberglass, BlownFiberglass, Batts Foundation Wall Output in Tons: Appliances Cooling System Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Make-up Air Select a Type Domestic Water Heater Model Heating System Rim Joist (1st Floor) Average U-Factor (excludes skylights and one door ) U: Duct system air tightness: Rating or Size Efficiency Heating Gain Cooling Load Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Residential Load Calculation SEER /EER Capacity continuous ventilation rate in cfms: Heating Loss Manufacturer Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Date Cert. Posted R-value MECHANICAL SYSTEMS Builders Associaton of Minnesota version 101014