Loading...
HomeMy WebLinkAboutLA17952 - 17952 Grantham Ln Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov Nick Reimler RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: SEE ROOF PLAN FOR ROOF PITCHES AND OVERHANGS 25'-9"CONC. PORCH 6:12 ALUM. SOFFIT & FASCIA 30 YR. ARCH. ASPHALT SHINGLES 2x OVER 8" TRIM 10" LP TRIM4'-6"9'-1 1/8"T.O. SUBFLR. T.O. PLATE 1'-8 1/4"T.O. FDN.6" TRIM 6" TRIM 10'-9 1/8"@ GARAGE T.O. PLATE 12 12 12 12 1'-6"7'-2 1/2"T.O. 3048 SH STAT. (BLACKENED) STONE WHERE INDICATED 12" CANT. 10" TRIM C/L T.O. FDN.7'-11"@ DORMER T.O. PLATE 10'-6"FP CHASE 24"x60" FALSE LP PANEL8:12 8:12 6:12 6" TRIM 6" TRIM 10" LP TRIM12" TRIM 12" TRIM 6" TRIM 6"LP PANEL 12 12 12 12 12 12 6'-0"STONECAP STONE TOTAL: 148.63 SQ. FT. (25.14%) TOTAL SQ. FT.: 591.11 MATERIAL CALCULATIONS: FRONT ELEV. LP TRIM / PANEL: 442.48 SQ. FT. (74.86%) STONE TOTAL: 199.63 SQ. FT. (7.30%) TOTAL SQ. FT.: 2734.37 MATERIAL CALCULATIONS: ALL ELEV. LP LAP SIDING TOTAL: 1672.84 SQ. FT. (61.18%) LP TRIM / PANEL: 861.90 SQ. FT. (31.52%)8" LP TRIM8" LP TRIM8" LP TRIM8" TRIM 12" TRIM LP PANELLP PANELGLS.GLS.GLS.GLS. ALUM. RAILING SADDLENOTE: SEE ROOF TRUSS LAYOUT FOR TRUSS DIRECTION AND GIRDER LOCATIONS PROVIDED BY MANUFACTURER PROVIDE ATTIC VENTILATION EQUAL TO 1/150th ATTIC AREA. IF 50% OR MORE IS PROVIDED IN UPPER PORTION OF THE ROOF AND REMAINDER IS PROVIDED IN SOFFIT VENTS, IT MAY BE REDUCED TO 1/300th ATTIC AREA. ICE AND WATER SHIELD 6'-0" IN FROM EAVES 1'-6" ON EACH SIDE OF VALLEY WHERE WALLS MEET ROOF ICE & WATER SHIELD SHOULD RUN UP WALL 1'-6" AND OUT FROM WALL 1'-6" NOTE: NOTE: NOTE: 1'-6"2'-0"RIDGERIDGE 1'-0"6:126:126:1212:12 2'-0"2'-0"4'-0"6:1212:1212:12 6:1212:12 1'-6" 1'-6"1'-6"2'-0"2'-0"6'-0"12:126:1212:12 12:121'-0"12:1212:12 1'-6"1'-6" GUTTERS SUPPLIED & INSTALLED - VERIFY LOCATIONS WITH CONTRACTOR NOTE: 1'-6"6:1212:12 1'-6" 12:12 1 7 SCALE: 1/4" = 1'-0" FRONT ELEVATION GENERAL NOTES: 1. ALL DOOR AND WINDOW HEADERS TO BE S.P.F. #2 OR BETTER, SEE PLANS FOR SIZES. 2. HOUSE TO BE BUILT PER CURRENT I.R.C. CODES. 3. VERIFY GRADES AND ADJUST FOUNDATION/FOOTING STEPS AS NEEDED. 4. SEE PLANS FOR CEILING HEIGHTS 5. 4' HIGH POURED FDN. WALLS STD. 6. FLOOR PLAN DIMENSIONS ARE TO FACE OF FRAMING AND FOUNDATION. 7. ALL TRADES & SUPPLIERS TO REVIEW & VERIFY INFORMATION PERTINENT TO THEIR WORK AND NOTIFY CONST. OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 8. NOTED CABINET SIZES ARE +/- AND TO BE FIELD VERIFIED. 9. TRADES TO VERIFY BASE AND TRIM SIZE PRIOR TO CONSTRUCTION. 10. ALL WALLS MORE THAN 10' H. TO BE S.P.F. #2 OR BETTER. 11. EXTERIOR ELEVATIONS ARE CONCEPTUAL ONLY: HOME SITE, FILL AND TOPOGRAPHY WILL DICTATE ACTUAL GRADES AND MAY VARY FROM THOSE SHOWN ON THE PLAN. 12. NOTE: SUBFLOOR JOINTS SHALL BE STAGGERED FROM FLOOR TRUSS OR JOIST JOINTS OF SHEET 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X17952 GRANTHAM LN., LAKEVILLELOT 21, BLOCK 5A, SUMMER'S CREEKHAMPTON 1760 PLANMARK ELLIOTT HOMES1-19-22 SELECT 2-8-22 UG REV. 2-17-22 UG REV. 2 5-4-2022 PERMIT SCALE: 1/8" = 1'-0" ROOF PLAN Concept Approval ONLY Subject to Field Inspection Inspector Date 2020 MN Bldg Code 06/22/2022dmathews @ GARAGE 9'-9 1/8"T.O. FDN. ALUM. SOFFIT & FASCIA A/C UNIT T.O. PLATE 9'-1 1/8"T.O. SUBFLR. T.O. FDN.1'-8 1/4"LP CORNERS 4" LP TRIM @ WDWS. & DOORS TYP. 12 6 12 6 LP SIDING PER SPECS T.O. PLATE SEE ROOF PLAN FOR PITCHES AND OVERHANGS 8" TRIM 7'-8"@ DORMER T.O. PLATE 12:12 12:12 12 6 LP PANEL 2'-0" VERIFY GRADE 12 6 12:12 LP PANEL10" TRIM WFPWFP 12:12 12:12 TOTAL SQ. FT.: 894.34 MATERIAL CALCULATIONS: RIGHT ELEV. STONE TOTAL: 10 SQ. FT. (1.12%) LP TRIM / PANEL: 64.5 SQ. FT. (7.21%) LP LAP SIDING TOTAL: 819.84 SQ. FT. (91.67%) ALUM. SOFFIT & FASCIA LP PANEL 12 6 T.O. PLATE 9'-1 1/8"T.O. SUBFLR. T.O. FDN.1'-8 1/4"12 6 10" TRIM 12" CANT.LP CORNERS 4" LP TRIM @ WDWS. & DOORS TYP. LP SIDING PER SPECS FP VENT SADDLE SEE ROOF PLAN FOR PITCHES AND OVERHANGS 12:12 12:12 12 6 LP PANELLP PANELVERIFY GRADE WFPWFP 12:12 10" TRIM TOTAL SQ. FT.: 778.50 MATERIAL CALCULATIONS: LEFT ELEV. LP TRIM / PANEL: 216.05 SQ. FT. (27.75%) LP LAP SIDING TOTAL: 521.45 SQ. FT. (66.98%) STONE TOTAL: 41 SQ. FT. (5.27%) T.O. PLATE 9'-1 1/8"T.O. SUBFLR. T.O. FDN.1'-8 1/4"LP CORNERS 4" LP TRIM @ WDWS. & DOORS TYP. 10" TRIM 12" CANT. WFPWFPWFPWFP SEE ROOF PLAN FOR PITCHES AND OVERHANGS ALUM. SOFFIT & FASCIA 6:12 LP SIDING PER SPECS 12 12 12 12 LP PANEL12 12 10" TRIM 6:12 10" TRIM WFPWFP 12" LP COL. (HOLD UP FROM GRADE AS REQUIRED) TOTAL SQ. FT.: 470.42 MATERIAL CALCULATIONS: REAR ELEV. LP LAP SIDING TOTAL: 331.55 SQ. FT. (70.48%) LP TRIM / PANEL: 138.87 SQ. FT. (29.52%) EXTERIOR ELEVATIONS ARE CONCEPTUAL ONLY: HOME SITE, FILL AND TOPOGRAPHY WILL DICTATE ACTUAL GRADES AND MAY VARY FROM THOSE SHOWN ON THE PLAN.2 7 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X17952 GRANTHAM LN., LAKEVILLELOT 21, BLOCK 5A, SUMMER'S CREEKHAMPTON 1760 PLANMARK ELLIOTT HOMES1-19-22 SELECT 2-8-22 UG REV. 2-17-22 UG REV. 2 5-4-2022 PERMIT OF SHEET SIDE ELEVATION SIDE ELEVATION SCALE: 3/16" = 1'-0" REAR ELEVATION SCALE: 3/16" = 1'-0" SCALE: 3/16" = 1'-0" Secure door closed until deck is constructed with a separate permit. A/C UNIT w/ BRACKET 96% FURN F.D. WH MECH. 30 6 8 CONC. H.B.H.B.2" LEDGE TYP. TO PROVIDE ADD'L. SUPPORT FOR FILL FOR SLAB TYP. FND @ HOUSE / GARAGE 10" POURED CONC. W/ 4" LEDGE INSIDE 20X8 CONC. FTG. 2" FOAM H20 4" LEDGE 2" FOAM TYP. FND @ STOOP 10" POURED CONC. W/ 4" LEDGE INSIDE 20x8 CONC. FTG. UNEXCAVATED 2" NOTE: NO DRYWALL @ CLG. REQUIRED IN THIS AREA - FIRE BLOCK @ PERIMETER OF OPNG. (80 SQ. FT. MAX.) 6"2" GARAGE/HOUSE COMMON WALL SEE FIRST FLOOR FOR GARAGE DOOR SIZE FOR M.O. NOTE: 4" LEDGE 6"2"3 1/2'' CONC. FLOOR TYP. FND @ HOUSE 8" POURED CONC. (8'-4" H.) 20X8 FTG REBAR PER CODE KITCHEN ISLAND ABV. FLR. TRUSS CO. 18" FLR. TRUSSES19.2" O.C. SPACING2-9 1/2" FOUND. HELD IN 2" FOR INSULATION NOTE: (TYP.) NOTE: EXTERIOR HOUSE AND GARAGE/HOUSE COMMON FDN. WALLS TO BE HELD 2'' IN. DIMENSIONS SHOWN ARE TO FACE OF 2'' EXTERIOR RIGID INSULATION & FRAMING ABOVE TO BE 5000 PSI CONC.NOTE: ALL FOOTINGS 2'' MIN. 2x8 TREATED SILL-OVERHANGFDN. 1 1/2''8" 2" TYP. SIDE WALL DETAIL FOUND. HELD IN 2" FOR INSULATION NOTE: (TYP.) 2" 2" UP 16 R (10" T., 7-3/4" MAX. R.) 40'-0"60'-0"76'-0"9'-0"31'-0"27'-0"9'-8"4'-8"9'-0 1/2"11'-6"5'-0"5'-6"16'-6"10'-6"7'-0" & HOUSE/PORCH 18" FLR. TRUSSES19.2" O.C. SPACINGFOUND. HELD IN 2" FOR INSULATION NOTE: (TYP.)12" CANT. ABV.2x6 BRG.2x6 BRG.18" FLR. TRUSSES19.2" O.C. SPACING9'-4" H. FOUND. WALL @ FRONT OF HOME NOTE: 9'-4" H. FOUND. WALL@ FRONT OF HOME NOTE: w/ TOP HUNG TRUSSES w/ TOP HUNG TRUSSES 9'-4" H. FOUND. WALL @ FRONT OF HOME NOTE: w/ TOP HUNG TRUSSES 10'-11"15'-11" 12'-3"3'-8 1/4"10'-10 3/4"9'-6"3'-9"3'-10"6'-10 1/2"21'-3"4'-1"21'-6"5'-10"13'-7 1/2" 2-2x10 (FL) (2) TR 2-9 1/2" LSL (DR) L.L. BATH 2"BEDRM. #4 FAMILY ROOM CARPET LVP FLOOR (11'-8"x11'-8") (24'-11"x12'-4")2"4'-0"2"14'-0"26'-0" 3'-8"9'-6" 60" VAN. TYP. FND @ BRG. WALL 2x4 STUDS 16" O.C. 16X8 FTG REBAR PER CODE 4" CONC. CURB (936 FIN., 826 UNFIN.) APPROX. 1,762 NET SQ. FT. 2-2x10 (FL) 20"x8" CONT. CONC. FTGS. REBAR PER CODE 42" H. x 8" W. POURED CONC. FOUNDATION WALL 2" RIGID INSULATION 1 TRTD. PLATE 6042 SLIDER @ 7' 2-9 1/2" LSL 8042 SLIDER @ 7' 3-9 1/2" LVL C.T. FLR. 8'-4" POURED FDN.TRP.H.TB7'-0"7'-0"16'-8"3'-0"FILL FOR SLAB 76'-0"40'-0" 6'-0" 20'-0" 10'-6"10'-6" 13'-0"21'-0" 12'-0" 6042 SLIDER @ 7' 2-9 1/2" LSL 5'-0"12'-2"8'-10" SD SMOKECM / EXCH.AIR 6" 4" 10" 2x8 TREATED SILL OVERHANG FDN. 2'' GARAGE SLAB 2'' RIGID INSUL. MAIN FLR SUMP RADON VENT TO TERMINATE IN SUMP BASKET RADON VENT 11'-0" 3-9 1/2" LSL (FL)18" FLR. TRUSSES19.2" O.C. SPACING28" DIA. FROSTFOOTING (60" D.) NOTE: R-30 INSUL. AT PORCH FLOOR 15'-5 1/2"9'-0"12'-0"GARAGE DROPPED 1 COURSE BY OWNERSHELVING NOTE: NOTE: DEEP JAMB NOTE: DEEP JAMB NOTE: DEEP JAMB 2x6 BRG. OFFICE CARPET (10'-9"x11'-11") U.C.REFR. 8'-0" F.D. LSL (FL)30683068STORAGE CONC. 3'-8" 2 8 6 8 24682x6 (4) SH. * IONIZER UNIT* 2-ZONE AUTO* WI-FI STATS. * AIR PURIFIER FILTER C.T. WALLS 60x34 SHWR. & FLOOR SHWR. DR.FRAMELESS 2 8 6 8 2868 PKT. DR.6042 SLIDER @ 7'2-9 1/2" LSL7'-0"5'-0"NOTE:DEEP JAMB12'-0" LOOKOUT WALLRGH.-INWATER SOFT. LNDRY. TUBFREE-STANDING w/ INSTALLED PUMP (VERIFY LOCATION)8'-4"4'-10"CARPET CARPET UPPERS NOTE: 4” SLEEVE ABOUT 2’ DOWN FROM THE TOP OF THE WALL BETWEEN THE GARAGE AND THE MECH ROOM FOR FLR. DRAIN R&SH R&SHCARPET2868NOTE: IN-FLR. HEAT NOTE: MIRRORSBY OWNERINSTALLEDBY SUBCON. ADA HT. 6x6 TRTD. COL. w/ 12" LP COL. WRAP 4 1/2"4 1/2"10'-3"4 1/2"STAIRWAY REINFORCEDTO ACCOMODATE APPROX. NOTE: 600# SAFE TO BE MOVED IN L.L.(ADD'L. STRINGERS, ETC.) RECESSED STEP SCALE: 3/16" = 1'-0" FOUNDATION PLAN 3 7 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X17952 GRANTHAM LN., LAKEVILLELOT 21, BLOCK 5A, SUMMER'S CREEKHAMPTON 1760 PLANMARK ELLIOTT HOMES1-19-22 SELECT 2-8-22 UG REV. 2-17-22 UG REV. 2 5-4-2022 PERMIT OF SHEET BWPs Above UFER Ground -Provide 20' Rebar in footing and stub up near electrical service panel. P.H.TBTRDW GAS RANGEMICRO ABV. LNDRY. DRYERw/ PAN 9' CLG. / LVP (VENT TO OUTSIDE) NOTE: - STD. BASE & CASING TO BE PRINCETON - 1/2 WALL w/ WD. CAP & INVERTED CASING NOTE: 2X6 EXT. WALLS U.N.O. 2X4 INT. WALLS U.N.O. - 42" UPPER CABINETS DOOR ROUGH OPENINGS: 83" HEIGHT 82" OVER VINYL CERAMIC TILE & WOOD 82" OVER CARPET SRO = SHEET ROCKED OPNG BIFOLD DOORS: PREHUNG UNITS: 2" WIDER THAN DOOR (EXAMPLE: 2668 ) 1 3/8" WIDER THAN DOOR FINISH SIZE NOTED ON PLAN CO = CASED OPENING ( WOOD ) (EXAMPLE: 2668 ) FINISH SIZE NOTED ON PLAN RO. 1 1/2" WIDER, 83" HIGH R.O. 1" WIDER, 83" HIGH PER SPECS DRIVEWAY NOTE: REF. KITCHEN 9' CLG. / LVP 12'-3" x 12'-6" (155 SQ. FT.) 2-11 7/8" LSL GREAT ROOM 36" GAS F.P.12'-8" x 13'-0" (167 SQ. FT.) 60x36 SHWR. 5'-0"210682-9 1/2" LSL FOYER 9' CLG. / LVP5'-11" x 10'-7" (63 SQ. FT.) PORCH CONCRETE O. BATH 9' CLG. / C.T. 2x6 WALLS U.N.O. 4" SLOPED CONC. GARAGE CEIL. TO BE 5/8" TYPE 'X'GYP. BD. WALLS TO BE 1/2" GYP.SHEATHING. ALL WALLS & CEILINGS TO BE FULLY TAPED, SANDED TO SMOOTH GARAGE 6'x8' PATIO DR.16'x7' INSULATED (R-18) O.H.D. R.O. 16'-1" FRAMING O. CLST 9' CLG. / CARPET BATH 2 BEDROOM #2 3648 SH @ 8'9' CLG. / CARPET 9' CLG. / C.T. RAILING PER SPECS MANUF. TRUSSES24 O.C.(12'-0"x12'-0") EXTERIOR FLOOR PLAN DIMENSIONS ARE TO OUTSIDE OF SHEATHING, INTERIOR DIMENSIONS ARE TO FRAMING. NOTE: ALL DRS/ WIN.'S REQUIRE 4" ON SIDES FOR CASING NOTE: 2X6 EXT. WALLS U.N.O.2X4 INT. WALLS U.N.O. HEADER SPANS: UP TO 4'-11'' = 1 TRIMMER 5'-0'' AND BIGGER = 2 TRIMMERS UNLESS NOTED OTHERWISE INDICATES LOCATION OF SOLID BRG.JETTED TUB PER (144 SQ. FT.) OWNERS BDRM. TRAY VAULT / CARPET (12'-6"x16'-0") (164 SQ. FT.) SMOKECM / SD 2 - 4072 SH @ 8' DN 16 R (10" T., 7-3/4" MAX. R.) 2x6 8/0 H. SOFFIT * BEADBD. CLG.ATTICACCESSAPPROX. 512 SQ. FT. MUDRM. 9' CLG. / LVP 3068 MTL.3080 MTL.2 - 20682 6 6 8 (6) SH. (6) SH. 9' CLG. / LVP 286836" VAN. 3 0 6 8 3068 PKT. 2 - 4072 SH @ 8' 60" VAN. DINING TRAY VAULT / CARPET10'-0" x 9'-0" (90 SQ. FT.) 3672 SH @ 8'3672 SH @ 8'4872 PICT. @ 8'MANUF. TRUSSES24 O.C.40'-0" 15'-5 1/2" 8'-10"5'-6"76'-0"60'-0"5'-9 1/2"4'-3 3/4"4'-3"12'-8 3/4"7"3'-11"5'-2 1/2"4'-4 3/4"6'-2 1/4"6'-6 1/2"76'-0"5'-0"31'-0"27'-0"14'-4"16'-8"3'-2"9'-0 1/2"5'-0"5'-6"16'-6"10'-6"40'-0" 7'-0" 20'-0" 10'-6"10'-6" PA SD 2'-4 1/4"1'-10 1/2"2424 PICT. @ 8'2424 PICT. @ 8'2'-0 1/2"2'-0 1/2"2448 SH @ 8'5'-0"CONC. STEPS 2'-9" 4'-4"3'-9"2'-9"5'-4 3/4"6'-1 1/4" 6'-1 1/4" 4'-8 3/4"4'-0 1/4" 7'-0 3/4" 2'-0" 1'-4" 7'-10"15'-0 1/2" 2'-7 1/2"2'-8"3'-10 1/2"2'-7 3/4"10'-0"5'-0"12" CANT.11'-4"5'-2"6'-8"7'-8"4'-0"12'-8"3'-9"3'-10"3'-5"3'-0"3'-0"3'-0"2-2x102-2x102-2x102-2x104 1/2"4 1/2" 8'-10 1/2"MANUF. TRUSSES24 O.C.FP CHASEFALSE 2-9 1/2" LSL (CONT.) 2-2x10 (2) TR (2) TR 2-2x10 2-2x10 P.H. TR TB 3'-5" 42" W. CONC. SIDEWALK 28682 - 4072 SH @ 8'2-9 1/2" LSL3'-8 1/2"12'-8 7/8"BEDRM. #3 / OFFICE 9' CLG. / LVP (12'-3"x8'-0") (124 SQ. FT.) 4'-7"8'-5"286813'-0" 6'-6"6'-6"4'-0"4'-0"5'-6"6'-9 1/2"6'-9" 13'-6 1/2"12'-0"11 3/4"9'-4"2x6 SD 4'-0"3'-0"3'-6"7'-0" 21'-0" 12'-0" 6'-0" GIRDER TRUSS BUFFET BASE CAB. ONLY3'-4" STUD GIRDER TRUSS MANUF. TRUSSES 24 O.C. APPROX. 9'-0'' CLG. @ MAIN LEVEL APPROX. 1,762 SQ. FT. 11'-6"1'-5"36" VAN. LIN. CAB.(TEMP)@ SAME HT. FRAME WALL AS HOUSE 9'-0"BEARING FOR TRUSSESUSE WALL AS MID- NOTE: NOTE: 12'-11 1/4" 3 1/2" MANUF. TRUSSES 24 O.C. 18" LP COL.2-9 1/2" LP SOFFIT 2x4 FRAMING 3" 2-9 1/2" LSL (DR) 1'-2"3"1'-2"3-9 1/2" LSL (DR)5'-2"3"1'-2" 4-SEASON PORCH VAULTED CLG. / CARPET 2-9 1/2" LSL (FULL LENGTH)MANUF. TRUSSES 24 O.C.3-9 1/2" LSL (FULL LENGTH)11'-0" 6'-7 1/2" 7/0 x 8/0 SRO 2-9 1/2" LSL 2 - 4072 SH @ 8'2-2x10 2 - 4072 SH @ 8'9'-0"4'-9"6'-3"SHLVS. ABV.6:12 SLOPE6:12 SLOPE GARAGE DROPPED 2'-0" TOWER 18" H. BENCH BACK BEADBD. w/ 8' STORM DR.BUILT-IN w/SHLVS. ABV.BUILT-IN w/BY OWNER SHELVING NOTE: BY OWNERSHELVING NOTE: BY OWNERSHELVING NOTE: 2868 PKT. TRAY VAULT / CARPET 2'-0"2'-0"TYP. 4:12 TYP.4:122424 FX @ 8'2424 FX @ 8'3'-8"9'-0"4'-0"NOTE: PROVIDE BACKING AT (4) LOCATIONS IN SOFFIT TO BE FIELDLOCATED FOR FUT. SECURITY CAMERAS SHWR. DR.FRAMELESS 8'-0" LSL (DR)UPPER CABS. PULL-OUT DBL. BASKET UTIL.CAB. F.D. FINISH & PAINTED CLG. FULLY INSULATEDGARAGE WALLS & NOTE:w/ FAN / REMOTEC.T. WALLS& FLOOR DISP H.B. H.B. 5/0 BI-PASS R&SH 8'-11" FLAT LIN.CAB.8'-6 5/8"2'-4 1/2"SPECS2'-10" BY OWNERSHELVING NOTE: RADON VENT CARPET LVP APPROX. 40" W. WASTE 2868L.S. C'TOP. OVER W/D 2-PANELNOTE: IN-FLR. HEAT NOTE: IN-FLR. HEAT NOTE: MIRRORSBY OWNERINSTALLEDBY SUBCON. NOTE:MIRRORS BY OWNERINSTALLEDBY SUBCON. ADA HT. ADA HT.WASHER NOTE: PROVIDE BACKING AT (4) LOCATIONS IN SOFFIT TO BE FIELDLOCATED FOR FUT. SECURITY CAMERAS 3'-1 3/4"2'-7 3/4"4824 PICT. @ 8'STAIRWAY REINFORCEDTO ACCOMODATE APPROX. NOTE: 600# SAFE TO BE MOVED IN L.L.(ADD'L. STRINGERS, ETC.) ALUM. RAILING RECESSED STEP TOWARDS DRAINCONC. FLOOR SLOPED NOTE:2 8 6 8 NOTE: HIGH LOOP AIRGAP METHOD w/ STEPS PER GRADE ALUM. RAILING SCALE: 3/16" = 1'-0" MAIN FLOOR PLAN 4 7 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X17952 GRANTHAM LN., LAKEVILLELOT 21, BLOCK 5A, SUMMER'S CREEKHAMPTON 1760 PLANMARK ELLIOTT HOMES1-19-22 SELECT 2-8-22 UG REV. 2-17-22 UG REV. 2 5-4-2022 PERMIT OF SHEET Smoke CO CS-PF CS-PF CS-PF CS-PF CS-PF CS-PF CS-PF CS-PF 8 8 -Min. 15" clearance to any obstruction from center of W.C., 24" in front(typ). R-5 THERMAX AT INTERIOR FOUND. AS REQUIRED 3/4" T & G FLOOR NOTE: SUBFLOOR JOINTS SHALL BESTAGGERED FROM FLOOR TRUSS ORJOIST JOINTS R=0.61 R=49.00 R=50.25 R=0.58 R=.061 TOTAL TRUSSES - 24" OC BLOWN INSULATION INTERIOR AIR FILM VAPOR BARRIER 15/32" OSB SHTG. 15# FELT EXTERIOR AIR FILM ICE AND SNOW SHIELD 30 YR. ARCH. ASPHALT SHINGLES 5/8" GYP BD ALUM. SOFFIT & FASCIA 1/2" GYP BD INTERIOR AIR FILM TOTAL SIDING PER SPECS 2x6 STUDS 16" OC R=1.06 R= R= R=21.00 R=0.45 R=0.17 R=23.36 VAPOR BARRIER FULL WALL BATT INSUL. EXTERIOR AIR FILM R=0.68 7/16" OSB SHTG. 8" AGGREGATE6 MIL POLY. LAP SEAMS 12"1'-4"HEEL HT.1/2" GYP. SHEATHING ON GARAGE WALLS 5/8" TYPE 'X' GYP. BD. ON GARAGE CEILS. 18" FLOOR TRUSSES1'-6 3/4"9'-1 1/8"T.O. LOOKOUT T.O. SUBFLR. T.O. PLATE TRUSSES @ 24" O.C. (DESIGNED BY MFR) 6 12 R-49 INSUL.9'-4"GARAGE 4" SLOPED CONC. W/ REBAR PER ENGINEERS REPORT 9'-4" POURED WALL DRAIN TILE 10" POURED WALL R-5 INSUL. ATINTERIOR FOUND.10'-9 1/8"O. BATH OWNERS BDRM. 20x8 CONC. FTG.16x8 CONC. FTG. 16x8 CONC. FTG. SPRAY FOAM RIM 8'-2" +/-FOUND. HELD IN 2" FOR INSULATION TYP. NOTE: (INSUL. FLUSH w/ SHTG.) CANT. 2x8 SILL PLT. 1-1/2" 3 1/2" CONC. FLOOR 2" RIGID INSULATION R-10 w/ WATCHDOG WATERPROOF COATING AROUND HOUSE FOUND. 20x8 CONC. FTG.8 1/4"6"HEEL HT.6 12 11"HEEL HT.3'-6"FUT. BDRM. #5 R.I. BATH 8 1/4"3'-6"7'-8"6 12 NOTE: TOP HUNG TRUSSES AT FRONT OF HOME (9'-4" H. FDN. WALL) SPRAY FOAM RIM 4"28"6 3/4" +/-JOIST W/ 2-3/8" LAG BOLTS ICE & WATER EXTENDS5" UP SHEATING UNDER INSTALL TOP OF LEDGER 3 5/8" BELOW TOP OF 3/4" SUBFLOOR (THIS ALLOWS 5/4 X 4 THRESHOLD AT DOOR) HANGER TREATED 2X10 LEDGER RUN HOUSE WRAP BEHIND LEDGER (LEAVE 6" TAIL @ TOP, BOTTOM, & SIDES) HOUSEWRAP @ 24" O.C. -OR- EMBED 2" MIN. 8 INCHES O.C. MAX OR EQUAL, W/ "LEDERLOK" FASTENERS CONT. 2X4 RIBBON SPRAY FOAM INSUL. R-21 MIN. RIM BOARD TREATED JOIST JOIST RIM BD. SKIRT 1" HOUSE END OF DECK HOUSE LATERAL LOAD SIMPSON DTT1Z DECK-TO CONNECTOR - (4) PER DECK OR 8-10DX1 1/2" NAILS 6-SD#9X1 1/2" SCREWS HDG WASHER OR SDWH 3/8" HDG LAG SCREW WITH TIMBER-HEX HDG SCREW (SHOWN) INTO TOP PLATE, STUDS, OR HEADER CONT. 2X8 RIBBON DRAIN TILE 3/4" WASHED ROCK CONTINUOUS UNDER SLAB0'-16" SILT FABRIC FOUNDATION WALL CONC. FTG. 4" DRAIN TILE 2 SCALE: NO SCALE5 TOP OF FDN.RIM DETAIL3 SCALE: NO SCALE5 2" RIGID INSULATION R-10 w/ WATCHDOG WATERPROOF COATING AROUND HOUSE FOUND. 2" RIGID INSULATION R-10 w/ WATCHDOG WATERPROOF COATING AROUND HOUSE FOUND. 2x8 TRTD. SILL SHEATHING FLUSH WITH INSULATION NOTE: FOUNDATION TO BE HELD IN 2" FROM SHEATHING & OUTSIDE DIMENSIONS. CANTED 1-1/2" 5 7 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X17952 GRANTHAM LN., LAKEVILLELOT 21, BLOCK 5A, SUMMER'S CREEKHAMPTON 1760 PLANMARK ELLIOTT HOMES1-19-22 SELECT 2-8-22 UG REV. 2-17-22 UG REV. 2 5-4-2022 PERMIT OF SHEET SCALE: 1/4" = 1'-0" SECTION1 5 N.T.S. HOUSE / DECK CONNECTION DETAIL4 5 SIMPSON STRONG TIE Ab46z HEADER HURRICANE CLIP ATTACHEDTO COLUMN& BEAM 11 7/8" OSB STRINGER W/ 2X4 BRACING 10 1/2" BULLNOSE LSL TREAD 1X8 PINE S4S RISER NOTE: MAX RISE= 7 3/4"MIN. RUN= 10" 6'-8" CLEAR HEADROOM BATH 2GREAT RM. 3/4" T & G FLOOR NOTE: SUBFLOOR JOINTS SHALL BESTAGGERED FROM FLOOR TRUSS ORJOIST JOINTS 8" AGGREGATE6 MIL POLY. LAP SEAMS 12" 18" FLOOR TRUSSES9'-1 1/8"T.O. SUBFLR. T.O. PLATE TRUSSES @ 24" O.C. (DESIGNED BY MFR) R-49 INSUL.9'-4"W/ REBAR PER ENGINEERS REPORT 9'-4" POURED WALL DRAIN TILE 10" POURED WALL R-5 INSUL. ATINTERIOR FOUND. 20x8 CONC. FTG.16x8 CONC. FTG. SPRAY FOAM RIM 8'-2" +/-FOUND. HELD IN 2" FOR INSULATION TYP. NOTE: (INSUL. FLUSH w/ SHTG.) CANT. 2x8 SILL PLT. 1-1/2" 3 1/2" CONC. FLOOR 2" RIGID INSULATION R-10 w/ WATCHDOG WATERPROOF COATING AROUND HOUSE FOUND. PORCH 18" SQ.LP COLUMN 20x8 CONC. FTG. MECH. / STORAGEFAMILY ROOM 3'-6"KITCHEN 8 1/4"4x4 TRTD. COL. LP TRIM 2 5 3 5 ALUM. SOFFIT & FASCIA 1'-4"HEEL HT.6 12 6 12 R-5 THERMAX AT INTERIOR FOUND. AS REQUIRED1'-6 3/4"T.O. LOOKOUT 4" LEDGE NOTE: TOP HUNG TRUSSES AT FRONT OF HOME (9'-4" H. FDN. WALL) CONC. STOOP6 3/4" +/-4"SPRAY FOAM RIM 16RFLEX ROOMBEDRM. #3 / OFFICE 6 12 SIMPSON STHD14 HOLD DOWN SIMPSON LSTA36 STRAP ON INSIDE FACE OF WALL 5/8" ANCHOR BOLT 1/2" OSB SHEATHING HEADER- SEE PLAN FOR SIZE FASTEN SHEATHING TO HEADER WITH 8d COMMON OR GALVANIZED BOX NAILS IN 3" GRID PATTERN ASSHOWN, AND 3" O.C. IN ALL FRAMING MEMBERS TYP. SHEATHING SPLICE (IF NEEDED) MUST BE LOCATED WITH-IN 24" OF THE MID HEIGHT OF THE DOOR OPENING. PROVIDE 2-2X6BLOCKING BEHIND SPLICE FASTEN TOP PLATE TO HEADER WITH2 ROWS OF 16d SINKER NAILS 3" O.C. BLOCK BACK SIDE OF HEADER FLUSH WITH STUDSAT STRAP LOCATIONS UNEXCAVATED SOIL ALL SLABS WILL HAVE A MIN. 4" CLEAN AGGREGATE, COVERED BY 6 MIL POLY. THIS POLY WILL HAVE 12" LAP AT ALL SEAMS. ALL TEARS OR PUNCTURES WILL BE SEALED OR COVERED BY POLY. ALL OPENINGS WILL BE SEALED USING POLYURETHANE CAULK OR ELASTOMERIC SEALANT AT ALL OPNGS. AN INSTALLED 3" GASTIGHT PVC PIPE WILL BE CONNECTED TO THE DRAIN TILE SYSTEM. A "T" FITTING WILL BE INSTALLED WITH 10 L.F. EACH END OF THE "T", OF PERFORATED PIPE, INTO THE DRAIN TILE SYSTEM. THE SHORTEST ROUTE WILL BE USED TO EXIT THE ROOF SYSTEM, WITH A MAX. OF 2 90 DEGREE ELBOWS. IN UNCONDITIONED AREAS, THE RADON EXHAUST PIPE WILL BE INSULATED WITH AN R4 SLEEVE. THIS PIPE WILL BE LABELED "PASSIVE RADON" AT ALL ACCESSIBLE LOCATIONS. AT ROOF EXIT LOCATIONS, MAINTAIN A 10' DISTANCE TO ANY WINDOW LOCATION, 2' BELOW EXHAUST POINT AND ANY ADJACENT STRUCTURE. THE LOCATION OF THE EXIT POINT, IN TRUSS AREA, WILL BE CLEAR OF ANY OBSTRUCTIONS WITHIN 24" HORIZONTALLY AND 36" VERTICALLY. INSTALL AN OUTLET AND PULL CHORD LIGHT FOR FUTURE EXHAUST FAN ADDITION. 6 7 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X17952 GRANTHAM LN., LAKEVILLELOT 21, BLOCK 5A, SUMMER'S CREEKHAMPTON 1760 PLANMARK ELLIOTT HOMES1-19-22 SELECT 2-8-22 UG REV. 2-17-22 UG REV. 2 5-4-2022 PERMIT OF SHEET SCALE: 1/4" = 1'-0" SECTION1 6 N.T.S. PORTAL FRAME DETAIL2 6 N.T.S. RADON DETAIL3 6 TVABV. FP.NOTE: TECH TUBE TV W.P.S3S3LTS. PENDANT 3 SS C/L 7'-11"3'-4"5'-1"SD GDO G.F.I.P. S G.F.I.P. W.P. S SS 3 S3S3S3S3SS S3 SS3 SSS3DISP S SS3 STO LIGHT S G.F.I.P.G.F.I.P. SD SC/L IN CAB. DW GAS RANGEMICRO ABV.(VENT TO OUTSIDE) REF. SMOKE CM / SMOKECM / G.F.I.P.G.F.I.P.S LNDRY. KITCHEN GREAT ROOM FOYER PORCH O. BATH GARAGE O. CLST BATH 2 BEDROOM #2 OWNERS BDRM.ATTICACCESSMUDRM. DINING BEDRM. #3 / OFFICE 4-SEASON PORCH S SS SD SNOTE: WIRING ASREQ. FOR JETTED TUB NOTE: OUTLETFOR FUT.WASHLET S NOTE: U.C. LEDTAPE LTS. NOTE: U.C. LEDTAPE LTS. S (FIELD VERIFY) NOTE: MULTI-MEDIA JACKw/ CAT6 & QUAD OUTLET(AT TOP SH. HT.) 48" AFFIN CAB. 200 AMPELEC. PANEL G.F.I.P. STD. HT. W.P.SS S CLG. FAN / LIGHT INSTALLED TV(FIELD VERIFY) W.P. OUTLETS NOTE: (2) FLR. TV NOTE: 120V FREEZER OUTLET(FIELD VERIFY LOCATION) TV 220 OUTLET T NOTE: w/ FAN /REMOTE WALK-THROUGH WITH HOMEOWNER TO VERIFY LCOATIONS OF RGH.-INS, NOTE: ADD'L. ELEC. & LV NEEDS MIN. 1-1/2" INSIDE NOTE: OUTLET UNDERSINK FOR POWEREDTOUCH FAUCET ABV. CAB. ABV. CAB. NOTE: WIRING FORIN-FLR. HEAT NOTE: WIRING FORIN-FLR. HEAT NOTE: OUTLET @ EYE LEVEL(VERIFYLOCATION) NOTE: REFER TOMIRROR SPECS FOR SCONCE HTS. NOTE: REFER TOMIRRORSPECS FOR SCONCE HTS. (VERIFY LOCATION)EQ.EQ.DUPLEX CONVENIENCE OUTLET DUPLEX OUTLET ABOVE COUNTER WEATHERPROOF DUPLEX OUTLET HALF-SWITCHED DUPLEX OUTLET DUPLEX OUTLET IN FLOOR 220 VOLT OUTLET WALL SWITCH THREE-WAY SWITCH FOUR-WAY SWITCH CEILING MOUNTED INCANDESCENT LIGHT FIXTURE WALL MOUNTED INCANDESCENT LIGHT FIXTURE RECESSED INCANDESCENT LIGHT FIXTURE LIGHT FIXTURE WITH PULL CHAIN TRACK LIGHT FLOURESCENT LIGHT FIXTURE EXHAUST FAN EXHAUST FAN/LIGHT COMBINATION CHIMES (OPTIONAL) SMOKE DETECTOR TELEPHONE (OPTIONAL) TELEVISION (OPTIONAL) THERMOSTAT ELECTRIC METER ELECTRIC PANEL SPEAKER (OPTIONAL) TV T M CH SD P.C. S S S 4 3 W.P. ELECTRICAL KEY DUPLEX OUTLET (GROUND FAULT PROTECTED)G.F.I.P. RECESSED INCANDESCENT EYE BALL FIXTURE CARBON MONOXIDE DETECTORCM GARAGE DOOR OPENER OUTLETGDO FLUORESCENT LIGHT PER SPEC FAN/LIGHT COMBO PREWIRE, PROVIDE ADEQUATE SUPPORT 4 BULB FIXTURE 3 BULB FIXTURE 200 AMP SERVICE LIGHTING PACKAGE: T.B.D. LINE TO DRYER: T.B.D. G.F.I.P. SMOKECM / S S3S TO LIGHT A/C UNIT w/ BRACKET G.F.I.P. SMOKECM / S SSG.F.I.P.TV S3S OUTLETNOTE: FLR. F.D. WH MECH. L.L. BATH BEDRM. #4 FAMILY ROOM SD EXCH.AIR SUMP OFFICE U.C.REFR. STORAGE * IONIZER UNIT * 2-ZONE AUTO* WI-FI STATS. RGH.-INWATER SOFT. LNDRY. TUBFREE-STANDING (VERIFY LOCATION)SSH20 S S SD S3 3 3 S4 S NOTE: U.C. LEDTAPE LTS. S NOTE: TECH TUBE(VERIFY LOCATION - NOTE: TECH TUBE(FIELD VERIFY) TECH TUBE TO RUNFROM OFFICE TO PANTRY TV TV (FIELD VERIFY) OUTLETNOTE: FLR. (FIELD VERIFY)ST PENDANT WALK-THROUGH WITH HOMEOWNER TO VERIFY LCOATIONS OF RGH.-INS, NOTE: ADD'L. ELEC. & LV NEEDS MEDIA JACK) S CAT 6 & TV (VERIFY LOCATION) NOTE: WIRING FORIN-FLR. HEAT NOTE: REFER TOMIRROR SPECS FOR SCONCE HTS. 96% FURN * AIR PURIFIER FILTER SCALE: 1/4" = 1'-0" MAIN FLR. ELECTRICAL PLAN 7 7 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X17952 GRANTHAM LN., LAKEVILLELOT 21, BLOCK 5A, SUMMER'S CREEKHAMPTON 1760 PLANMARK ELLIOTT HOMES1-19-22 SELECT 2-8-22 UG REV. 2-17-22 UG REV. 2 5-4-2022 PERMIT OF SHEET SCALE: 1/4" = 1'-0" LOWER LEVEL ELECTRICAL PLAN GARAGE PORTAL FRAMING PER BUILDING CODE IRC R602.10.6.4 BRACED WALL METHOD CS-WSP 3'-2" PANEL4'-0" PANEL4'-0" PANEL4'-0" PANEL4'-0" PANEL4'-0" PANELBRACED WALLLINE 1BRACED WALLLINE A BRACED WALL LINE CBRACED WALLLINE 24'-0" PANEL4'-0" PANEL4'-0" PANEL4'-0" PANEL3'-2" PANEL 3'-5" PANEL 3'-5" PANEL3'-1" PANEL BRACED WALL LINE B 8'-0" GYP. PANEL 8'-0" GYP. PANEL 1'-4" PANEL 1'-4" PANEL 3'-11" PANELPORTAL FRAMING PERBUILDING CODE IRC R602.10.6.4PORTAL FRAMING PERBUILDING CODE IRC R602.10.6.4PORTAL FRAMING PER BUILDING CODE IRC R602.10.6.4 LNDRY. KITCHEN GREAT ROOM FOYER PORCH O. BATH GARAGE O. CLST BATH 2 BEDROOM #2 OWNERS BDRM.ATTICACCESSMUDRM. DINING BEDRM. #3 / OFFICE 4-SEASON PORCH MIN. 3''x11 1/4'' NET HEADER(STEEL HDR. PROHIBITED) EXTENT OF HEADER W/ SINGLE PORTAL FRAME ONE BRACED WALL PANEL 10'-0'' MAX. HEIGHT(TOP OF HDR.)TOP OF FDN. TOP OF CONC FLOOR AT OPENING MIN. 2-2x4 FRAMING STUD POST CONTINUOUS HEADER WITH DOUBLE PORTAL FRAMES TWO BRACED WALL PANELS 6' TO 18' OPENING FASTEN TOP PLATE TO HEADER W/ 2ROWS OF 16d SINKER NAILS @ 3'' O.C. TYP. 1000 LB. STRAP OPPOSITE SIDE OF SHEATHING FASTEN SHEATHING TO HEADER W/ 8d COMMON OR GALV. BOX NAILS IN 3'' GRIDPATTERN SHOWN AND 3'' O.C. IN ALLFRAMING(STUDS, BLOCK'G AND SILLS)TYP. MIN. WIDTH PER TABLE R602.10.5 3/8'' MIN. WOOD STRUCTURAL PANEL SHEATH'G. MIN. 2-2x4 MIN. 4200 LB. TIE DOWN DEVICE(EMBED INTOFOUNDATION AND NAILED INTO FRAMING MIN. (2) 1/2'' DIA. ANCHOR BOLT INSTALLED PER R403.1.6 W SEE LEFT FORTYP. PORTALFRAME CONST. FOR A PANEL SPLICE(IF NEEDED) PANEL EDGES SHALL BE BLOCKED AND OCCURWITHIN 24'' OF MID-HEIGHT. ONE ROW OF TYP. SHEATH'G. TOFRAMING NAILING IS REQUIRED.IF 2x4 BLOCK'G. IS USEDTHE 2x4'S MUST BE NAILED TOGETHER W/ 3 16dSINKER NAILS W/ 2''x2''x3/16'' PLATE WASHER12'-0'' MAX. HEIGHT(TOP OF WALL)FULL HEIGHT OF WALL - SEE TO RIGHT FOR SPLICESPONY WALL HT.EXTENT OF HEADER TENSION STRAP PERTABLE R602.10.6.4 (ONOPPOSITE SIDE OF SHEATHING ANCHOR BOLTSPER SECTION R403.1.6 BRACED WALL LINECONTINUOUSLYSHEATHED WITH WOOD STRUCTURALPANELS TOP OF FLOOR AT OPENING FLOOR FRAMING ASSEMBLY PER PLAN W/ WOOD STRUCTURAL PANEL SHEATHING TOP OF FLOOR AT OPENING FLOOR FRAMING ASSEMBLY PER PLAN WOOD STRUCTURAL PANEL SHEATHING TO TOP OF BAND OR RIM JOIST NAIL SOLE PLATE TO FLR FRAMING PERTABLE R602.3(1) (2) FRAMING ANCHORS APPLIED ACROSSSHEATHING JOINT WITH A CAPACITY OF 670# IN HORIZ. AND VERT. DIRECTIONS SEE LEFT FOR TYP. PORTALFRAME CONST. ON CONCRETE FOUNDATION ON RAISED WOOD FLOOR - FRAMING ANCHOR OPTION TOP OF FLOOR AT OPENING FLOOR FRAMING ASSEMBLY PER PLAN W/ WOOD STRUCTURAL PANEL SHEATHING TOP OF FLOOR AT OPENING FLOOR FRAMING ASSEMBLY PER PLAN WOOD STRUCTURAL PANEL SHEATHINGTO TOP OF BAND OR RIM JOIST NAIL SOLE PLATE TO FLR FRAMING PERTABLE R602.3(1) SEE LEFT FORTYP. PORTALFRAME CONST. ON RAISED WOOD FLOOR - OVERLAP FLOOR OPTION MIN. OVERLAP 9 1/4''WOOD STRUCTURAL PANEL SHEATHING CONTINUOUS OVER BAND OR RIM JOIST MIN. OVERLAP 9 1/4''ATTACH TO RIM/BAND JOIST W/ 8d COMMON NAILS AT 3'' O.C. AS SHOWN DBL TOP PLATE BOTTOM PLATE STUDS AT 16'' O.C. W/ 6d NAILS @ 6'' O.C. 4'-0"8'-0'' MIN., SEE PLANINTERMEDIATE 6''3"W/ 6d NAILS @ 3'' O.C. EDGES NAILED BDRM. #5 FAMILY ROOM BRACED WALL LINE D 4'-0" PANEL 4'-0" PANEL 4'-0" PANEL 4'-0" PANEL BW 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X17952 GRANTHAM LN., LAKEVILLELOT 21, BLOCK 5A, SUMMER'S CREEKHAMPTON 1760 PLANMARK ELLIOTT HOMES1-19-22 SELECT 2-8-22 UG REV. 2-17-22 UG REV. 2 5-4-2022 PERMIT SHEETN.T.S. MAIN LEVEL BRACEWALL2 BW N.T.S. BRACEWALL DETAILS3 BW N.T.S. LOWER LEVEL BRACEWALL1 BW Date Certificate Posted X Passive (No Fan )Active (With fan and monometer or other system monitoring device) Location (or future location) of Fan: Other Please Describe Here R-15 R-20 X R-21 X R-49 X N/A R-30 X N/A X Not applicable, all ducts located in conditioned space X Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS: 60,000 Capacity in Gallons: Other, describe: AFUE or HSPF% 92 Cfm's " round duct OR " metal duct X Not required per mech. code Passive Low: Other, describe: X Low: Location of fan(s), describe: Cfm's 6" " Flex duct OR " metal duct BC665904 City Mailing Address of the Dwelling or Dwelling Unit Combustion Air Select a Type Location of duct or system: 19,800 Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel.Place your logo here New Construction Energy Code Compliance Certificate Name of Residential Contractor Mark Elliot Homes MN License Number Interior Below Entire Slab Rigid, Extruded PolystyreneLakeville17952 Grantham Ln THERMAL ENVELOPE RADON CONTROL SYSTEM Total R-Value of all Types of InsulationType: Check All That Apply Mineral FiberboardMechanical Room Heat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: Ceiling, flat Attic Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area Rim Joist (2nd Floor+) 0.29 Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade Appliances Cooling System Insulation Location Foam, Closed Cell0.28 Describe other insulated areas Interior WallsNon or Not ApplicableFiberglass, BlownFiberglass, Batts Foundation Wall R-value Average U-Factor (excludes skylights and one door ) U: Duct system air tightness: Building envelope air tightness: Attic Rim Joist (1st Floor) PROG50 113ANA024 Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Electric Make-up Air Select a Type Rheem Domestic Water Heater MECHANICAL SYSTEMS Rating or Size Efficiency 2 46,300 Heating Gain Cooling Load 13 SEER R4 10 Model Heating System 50 100 200 Select Type 0.7 Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): 19,800Residential Load Calculation SEER /EER NAT Gas Bryant 91250036060 Heating Loss Manufacturer Bryant NAT Gas Output in Tons: Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Capacity continuous ventilation rate in cfms: Builders Associaton of Minnesota version 101014 NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. A National Pollutant Discharge Elimination System (NPDES) Construction Stormwater Permit is required for “Construction activity that results in land disturbance of equal to or greater than one (1) acre or if a project is part of a common plan of development that will ultimately disturb greater than one (1) acre,” (NPDES Permit, Section 1.2). Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ *Primary Company Contact: _________________________________________________________________ *Should a site be deemed noncompliant, this individual will be notified Phone #: ____________________________ Email: ______________________________________________ If you are not covered under a NPDES Construction Stormwater Permit administered by the Minnesota Pollution Control Agency (MPCA), an erosion and sediment control plan MUST be approved as part of the residential building permit application. “Permittees must ensure a trained person will inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than ½ inch in 24 hours,” (NPDES Permit, Section 11.2). The City of Lakeville reserves the right to request weekly inspection logs. The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name: ____________________________________ Company: ___________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: __________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed I understand the above information to be accurate and I have read, understood, and accepted all terms and conditions of the NPDES Permit (MN R 100001). Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 6/13/22 X PM