Loading...
HomeMy WebLinkAbout7094 181st St WRECEIVED By Lucas Ritchie at 8:22 am, Jul 07, 2022 CITY OF LAKEVILLE CERTIFICATION OF GRADING AND FINAL PLACEMENT OF IRON MONUMENTS 7094 - #LA191800, 7088 - #LA191799 Building Permit #: 7082 - #LA191798, 7076 - #LA191797, 7070 - #LA191796 Legal Description: Lot 11-15BIock 2 Subdivision: GLACIER CREEK Address: 7094 7088 7082 7076 7070 181 st Street West We hereby certify that on 22nd day of June . 2022 an inspection of this property was conducted by me or under my direct supervision and that the as -built grades, elevations and drainage patterns of the site and building are in conformance with the grading plan approved by the City Engineer or amendments previously approved by the City Engineer. In addition, all property corner monuments are in place as of this date. Exceptions noted. I hereby certify that this survey, plan or report was prepared by me or under my direct supervision and that I am a duly Licensed Land Surveyor under the laws of the State of Minnesota. Print Name: �f9P ,,ter 3/ Hawkinson Signature: / r .f ( 9 v� Date: June 27, 2022 MN License #: 42299 NOTE: ATTACH A COPY OF THE CERTIFICATE OF SURVEY SHOWING ALL AS - BUILT GRADES, ELEVATIONS AND DRAINAGE PATTERNS Approved subdivision grading plans should be obtained from the property owner or developer. General questions relating to the building permit should be directed to the Building Inspections Department at 952-985-4440. Questions relating to grading should be directed to the Engineering Department at 952-985-4500. Prior to release of the Grading Security, this document shall be filed with: City of Lakeville Engineering Department 20195 Holyoke Avenue Lakeville, MN 55044 973.9 / / / 973.6 973.7 /♦ 975.0 O 975.1 / S / / 7 /X 974.4 975.4 x X 976 4 General ` . tes: 1. Grading plan by Pioneer last dated 5-22\70 was used to determine proposed elevations shown herein. 2. This survey do\not purport to show improvements or encroachments, except ‘a.,s shown, as surveyed by me or under my direct supervision\ 3. Proposed building dimensions shown are for horizontal location of structures on the lot only. Contact builder prior to construction for approved construction plans. 4. No specific soils investigation has been performed on this lot by the surveyor. The suitability of soils to support the specific house proposed is not the responsibility of the surveyor 5. This certificate does not purport to show easements other than those shown on the recorded plat. 6. Bearings shown are based on an assumed datum. 973 5 X 9740 :P di O x 976.3 J N 1 Install rock construction entrance. 2 Install silt fence as needed for erosion control. 3 Sidewalks shall drain away from house a minimum of 1.0%. 4 Contractor must verify driveway design. 5 Contractor must verify service elevation prior to construction. 6 Add or remove foundation ledge as required. 7 Retaining walls are conditional; Wall installed if the grade exceeds 3 1. Wall will not be installed if the grade is 3:1 or less / /N 52784664'7 X 974.2 974.1 x 974.7 977.5 42. x 9729 L"7 g01921 q" E / N:1781310.95 E 527874.55 ; 974.1 2.9% 974.0 1.131 74.1 --I 2 9 / N• 178832.40 / El527900.96 972.8 N 178821 13 e. E.527896.62 I►t, 973.3 X 973 6 973.9 N 178818.99 E 527897 58 973.4 µ aU se Aspen 9746 111r poc 974 9 974.6 x 972.8 x 974.6 32.0 975.0 34. 974.9 X 974. 40 974.E X 974.4 974 7 2.00 974 9 974 8 974 9 2.2.2 974 9 974.9 P°ttO 81 o 12.0 974.3 x 974 0 z.o x 971.7 • Denotes iron pipe 460 Denotes service ❑O Denotes television box ▪ Denotes electric box ❑� Denotes telephone box X 000.00 Denotes existing elevation c ODD.OD ) Denotes proposed elevation REVISED 6/22/22 GRADING Denotes drainage flow direction • Denotes spike • Denotes proposed retaining wall designed and built by others 32•00 974 2 1v2.6) 9721: 974.8 974.8 180.00 'i72.6 (72.4 9736, cm, X 9Z}.2..00 972.2 972 3 (72.1) N1178822.46 E• 527954.02 973.4 Driveway 974.6 X 974.3 974 974.4 974.4 974.1 X 974.0 N 178893.38 9717�4.94 and Ut1i1 Y proia9ent per rOkOt N 178888.08 � 9E7.5217905.69 , • 19 E per easem 1 971 3 N 178685.981 E 527916.4* C,p N•178681 26 MA)X 970.7 OS1 971 77928.89 974.7 97 citle 32.06 974 3 972.1 . `472.1 N 178823.38 E.527984.78 973.3 974.4 42•p0 X 974 6 974.7 974.4 x 972.0 -> x 971.6 _ >Y x 9733 Lowest opening elevation per grading plan :975.1 House elevations Top 0f Foundation Elev. Garage Slab Elev ® Door (Proposed) / As -built : (975.1) / 975.2 : (974.7) / 974.8 X 974.4 972.0,�.� Xe731 9 973.4 x ❑T 973 3 974.0 /" J W 974 9 co patio 0 120 X 974 3 10,0 975.1 42.00 � a7 0 x 973.7 0 0 0) 111X 74.2 973.6 974.4 975.0 X 974.2 971 9 x 972.9 973 2 `4972 1 972 : o973.2 '973 4 973.9 a73.6 X co //// O O X 9738 9 i 973.2 X 9738 CO 41. 974.0 x 974 0 X 973.7 972.8 1 X 971 9 »r 972.2 ->Y - -- '� x 972.3 -- Lot area = 147184735 House area"-97$z230 SF X 973 6 Stoop area = 140 SF Sidewalk area = 170 SF Driveway area = 910 SF Total Impervious Area = 9450 SF Impervious Coverage = 64.2% We hereby certify to Brandl Anderson Homes Inc that this survey, plan or report was prepared by me or under my direct supervision, and that I am a duly licensed Land Surveyor under the laws of the State of Minnesota, dated 04/02/21 Signed //Pi9peer Eggineering, P.A. AS -BUILT BY: Meter J Ha Non, tl'(otesslonal Land Surveyor Minnesota License No. 42299 email-phawkinson@pioneereng.com x 973.4 0' 20' Scale: 1" = 20' Benchmark: Top Nut Hydrant Elevation = Revisions 1 ) 04-05-21 Stake house 2 ) 06-14-21 Re -stake house 3 ) 06-22-22 Grading As -built U 0 L L m x 3 0 3 co N) r) co •o 0 to o o (73 C Wo w o 3 6. C)