Loading...
HomeMy WebLinkAboutLA203676 Soils ReportREVISED Letter of Transmittal 1 Bohn Well Drilling CompanyClient:Project No:B2206062 Date:July 08, 2022 To:Charlie Bohn Bohn Well Drilling Company 18190 Dairy Lane Jordan, MN 55352 Phone:(612) 919-1542 Email:charlie@bohnwell.com Braun Intertec Corporation 11001 Hampshire Ave S Bloomington, MN 55438 Re:19275 Iteri Avenue, Lakeville, MN 55044 Documents Sent Comments House Lot - 19275 Iteri Ave - BurdickProject: Daily Reports Daily Field Notes dated 6/28 and 6/29 Density Tests Tests 1-8 Other Daily Soil Observation Notes date 6/28/22 Proctor Tests P-01 Copy List Brandi Weckman, Bohn Well Drilling Company Joe Westphal, Braun Intertec Corporation Providing engineering and environmental solutions since 1957 Rev: 05/05/2014 Contact Information: Sent By: Email: Phone: Karen Ross Smith krosssmith@braunintertec.com (952) 995-2000 Activity Date:06/28/2022 Temperature:88 PM:Adam Raymond Technician:Connor, Dustin Report Number:1 Weather:Partly Cloudy Services Performed:Soil Density Testing Density Testing Method:Nuclear ­ ASTM D6938 Areas Tested:Building Pad Number of tests performed:5 Number of tests that met density requirements:5 Number of tests that did not meet density requirements:None Number of tests with results pending:None Fill source:Imported Type and source of imported fill: Contractor notified of test results:No Remarks / Comments Were all scheduled activities completed:Yes Were there any delays affecting our activities:No Report emailed to client or contractor:No General Comments: Compaction tests were taken on imported fill place up to basement sub­grade elevation on House Lot 19275 using nuclear density gauge. Tests taken passed according to site specifications. Daily Field Notes 11001 Hampshire Avenue S Minneapolis, MN 55438 Phone: 952­995­2000 Client: Bohn Well Drilling Company 18190 Dairy Lane Jordan, MN 55352 Project: B2206062 House Lot ­ 19275 Iteri Ave ­ Burdick 19275 Iteri Avenue Lakeville, MN 55044 Page 1 of 2Page 1 of 1 Dustin Connor Activity Date:06/29/2022 Temperature:79 PM:Adam Raymond Technician:Connor, Dustin Report Number:2 Weather:Sunny Services Performed:Soil Density Testing Density Testing Method:Nuclear ­ ASTM D6938 Areas Tested:Building Pad Number of tests performed:3 Number of tests that met density requirements:3 Number of tests that did not meet density requirements:None Number of tests with results pending:None Fill source:Imported Type and source of imported fill: Contractor notified of test results:No Remarks / Comments Were all scheduled activities completed:Yes Were there any delays affecting our activities:No Report emailed to client or contractor:No General Comments: Compaction tests were taken on imported fill place up to basement sub­grade elevation on House Lot 19275 using nuclear density gauge. Tests taken passed according to site specifications. Daily Field Notes 11001 Hampshire Avenue S Minneapolis, MN 55438 Phone: 952­995­2000 Client: Bohn Well Drilling Company 18190 Dairy Lane Jordan, MN 55352 Project: B2206062 House Lot ­ 19275 Iteri Ave ­ Burdick 19275 Iteri Avenue Lakeville, MN 55044 Page 1 of 2Page 1 of 1 Dustin Connor Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 1 Structural Fill : Building Pad: NW corner of building pad 1,044.0 Troxler / 3430 Plus / 71437 / 05/05/2020 Connor, Dustin 2 Structural Fill : Building Pad: SW corner of building pad 1,045.0 Troxler / 3430 Plus / 71437 / 05/05/2020 Connor, Dustin 3 Structural Fill : Building Pad: SW corner of building pad 1,047.0 Troxler / 3430 Plus / 71437 / 05/05/2020 Connor, Dustin 4 Structural Fill : Building Pad: SE corner of building pad 1,045.0 Troxler / 3430 Plus / 71437 / 05/05/2020 Connor, Dustin 5 Structural Fill : Building Pad: East side Center of building pad 1,046.0 Troxler / 3430 Plus / 71437 / 05/05/2020 Connor, Dustin Remarks A: Test results comply with specifications Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 1 06/28/22 P-01-std C Replace ment SP 12.9 120.9 6.3 120.7 128.3 12 100 98 A 2 06/28/22 P-01-std C Replace ment SP 12.9 120.9 7.4 120.3 129.2 12 100 98 A 3 06/28/22 P-01-std C Replace ment SP 12.9 120.9 6.6 120.9 128.9 12 100 98 A 4 06/28/22 P-01-std C Replace ment SP 12.9 120.9 6.5 121.7 129.6 12 101 98 A 5 06/28/22 P-01-std C Replace ment SP 12.9 120.9 6.1 121.3 128.7 12 100 98 A The results included in this report relate only to the items inspected or tested. Sample plan outlined in project specifications as applicable. Additionally, this report is for the exclusive use of the addressed parties. We assume no responsibility to other parties regarding this report. The information indicated in this report shall not be reproduced, except in full, without the prior written approval. Page 1 of 1 Field Compaction Report Test Method: ASTM D6938 Report Date: 07/05/2022 Client: Bohn Well Drilling Company Jordan, MN 55352 18190 Dairy Lane Project: House Lot - 19275 Iteri Ave - Burdick B2206062 Lakeville, MN 55044 19275 Iteri Avenue11001 Hampshire Avenue S Minneapolis, MN 55438 Phone: 952-995-2000 Adam Raymond 07/05/2022 Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 6 Structural Fill : Building Pad: Center of garage 1,047.0 Troxler / 3430 Plus / 71437 / 05/05/2020 Connor, Dustin 7 Structural Fill : Building Pad: 15' S, 15' W from NE corner of building pad 1,047.0 Troxler / 3430 Plus / 71437 / 05/05/2020 Connor, Dustin 8 Structural Fill : Building Pad: 10' S, 5' E from NW corner of building pad 1,047.0 Troxler / 3430 Plus / 71437 / 05/05/2020 Connor, Dustin Remarks A: Test results comply with specifications Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 6 06/29/22 P-01-std C Replace ment SP 12.9 120.9 7.4 121.2 130.2 12 100 98 A 7 06/29/22 P-01-std C Replace ment SP 12.9 120.9 8.1 121.2 131.0 12 100 98 A 8 06/29/22 P-01-std C Replace ment SP 12.9 120.9 7.2 121.1 129.8 12 100 98 A The results included in this report relate only to the items inspected or tested. Sample plan outlined in project specifications as applicable. Additionally, this report is for the exclusive use of the addressed parties. We assume no responsibility to other parties regarding this report. The information indicated in this report shall not be reproduced, except in full, without the prior written approval. Page 1 of 1 Field Compaction Report Test Method: ASTM D6938 Report Date: 07/08/2022 Client: Bohn Well Drilling Company Jordan, MN 55352 18190 Dairy Lane Project: House Lot - 19275 Iteri Ave - Burdick B2206062 Lakeville, MN 55044 19275 Iteri Avenue11001 Hampshire Avenue S Minneapolis, MN 55438 Phone: 952-995-2000 Adam Raymond 07/08/2022 Sample Information Sample Number:454921 Sample From:Stockpile Location:Structural Fill : Building Pad Sampled By:Connor, Dustin Location Details:House pad Sample Date:06/28/2022 Material:Imported Fill Received Date:06/28/2022 Lab:11001 Hampshire Ave S, Bloomington, MN Tested Date:06/29/2022 Tested By:Caamano, Lenit Laboratory Data Proctor ID:P­01­std Maximum Dry Density (pcf):120.9 Optimum Moisture (%):12.9 Method:Method B Preparation Method:Moist Rammer Type:Manual Round Specific Gravity:2.65 Specific Gravity Source:Assumed Passes #200 (%):2.6 Retained #200 (%):97.4 Retained On 3/4 (%):0 Retained On 3/8 (%):1 Retained On #4 (%):7 Passing #4 (%):93 Classification:SP Poorly graded sand, fine to medium grained, brown General Remarks:The % passing the #200 is for informational purposes only. Standard Proctor M­D Relationship ASTM D698 06/29/2022Report Date: 11001 Hampshire Avenue S Minneapolis, MN 55438 Phone: 952­995­2000 Client: Bohn Well Drilling Company 18190 Dairy Lane Jordan, MN 55352 Project: B2206062 House Lot ­ 19275 Iteri Ave ­ Burdick 19275 Iteri Avenue Lakeville, MN 55044 The results included in this report relate only to the items inspected or tested. Sample plan outlined in project specifications as applicable. Additionally, this report is for the exclusive use of the addressed parties. We assume no responsibility to other parties regarding this report. The information indicated in this report shall not be reproduced, except in full, without the prior written approval. Page 1 of 2Page 1 of 1