HomeMy WebLinkAbout19278 Hillcrest AveRECEIVED
By Lucas Ritchie at 12:14 pm, Jul 28, 2022
CITY OF LAKEVILLE
CERTIFICATION OF GRADING AND
FINAL PLACEMENT OF IRON MONUMENTS
Building Permit #: LA191152
Legal Description: Lot 9 Block 3
Subdivision: SUMMERLYN 9TH ADDITION
Address: 19278 Hillcrest Avenue
We
-F hereby certify that on 13th day of July , 2022 an inspection of
this property was conducted by me or under my direct supervision and that the as -built
grades, elevations and drainage patterns of the site and building are in conformance
with the grading plan approved by the City Engineer or amendments previously
approved by the City Engineer. In addition, all property corner monuments are in place
as of this date. Exceptions noted.
I hereby certify that this survey, plan or report was prepared by me or under my direct
supervision and that I am a duly Licensed Land Surveyor under the laws of the State of
Minnesota.
Print Name: �i9P .ter J! Hawkinson
9
Si nature: / c (I(
Date: July 21, 2022
MN License #: 42299
NOTE: ATTACH A COPY OF THE CERTIFICATE OF SURVEY SHOWING ALL AS -
BUILT GRADES, ELEVATIONS AND DRAINAGE PATTERNS
Approved subdivision grading plans should be obtained from the property owner or
developer. General questions relating to the building permit should be directed to the
Building Inspections Department at 952-985-4440. Questions relating to grading should
be directed to the Engineering Department at 952-985-4500.
Prior to release of the Grading Security, this document shall be filed with:
City of Lakeville
Engineering Department
20195 Holyoke Avenue
Lakeville, MN 55044
11x17
\\I
N
v
v
/
IIIII Denotes iron pipe
400 Denotes service
• Denotes television box
▪ Denotes electric box
E Denotes telephone box
X 000 00 Denotes existing elevation
( 000.00 ) Denotes proposed elevation
Denotes drainage flow direction
• Denotes spike
Denotes proposed retaining wall
designed and built by others.
30
X 1054 8
413° 1056 0 X 1057.2
x 1056 0
X 1057 7
.0-11055.2
CV X.1055.5 1056 7
- �k
1055.9
--�--- v 10539 10543
n541
N 172775.02, # 53-9 i +, �'
1054.3
E 518637 86
1053.6
1053 9
1053.7 x
1053.0
7051.7
1053 7
x 1054.0
1053 9
0
- X 1054.1
r-
1 30.5 'e
/ 1054.4
1054.3
N• 172719.42 105
E 518.644.50/ 1054.E 1051.E X 1053.1
050 8
10
1049 6 /
1054.3
�� 1----- x 1052 1
1050 C `51 6 X,01'..?
/1052 2
x
1054.4
1054.6
1053.5
1048 8
1050.0
O 1050
11.)C 1050.3E3
• jC 1049 8
/ X 1049.8
Construction Notes
1. Install rock construction entrance.
2. Install silt fence as needed for erosion control
3. Sidewalks shall drain away from house a minimum of 1.0%.
4. Contractor must verify driveway design.
5. Contractor must verify service elevation prior to construction.
6. Add or remove foundation ledge as required
7. Retaining walls are conditional; Wall installed if the grade exceeds 3:1.
Wall will not be installed if the grade is 3 1 or less.
General Notes
1. Grading plan by Pioneer last dated 10-24-2019 was used to determine
proposed elevations shown herein.
2. This survey does not purport to show improvements or encroachments,
except as shown, as surveyed by me or under my direct supervision.
3. Proposed building dimensions shown are for horizontal location of
structures on the lot only. Contact builder prior to construction for
approved construction plans
4. No specific soils investigation has been performed on this lot by the
surveyor The suitability of soils to support the specific house proposed is
not the responsibility of the surveyor.
5. This certificate does not purport to show easements other than those
shown on the recorded plat.
6. Bearings shown are based on an assumed datum.
1050 3
1050.2
X 1050k< 10506
1049 9
1051.0
1051 5
tob X 1051.1
S73C12'07./
4.
110588
1057 8 J057 4 1055.2
XagollS00116 To'Ss1.1111 1054 5
1056 0
1053 8
X 1051.8
1051 1
S87°44'24"E
Existing
House
1.0
Ici
X 1058.3
1053 4 1052.6
1054 8
1051.
X 1049.9
049.0
1050.3
1050 5
1053.5
x
1054 6
x 1052.7
1050 3
X 1049.8
1n466
1048.7
x
x 1050.0
142.88
X 10501
X 1048 8
1047 4
X 1047.5
10490 1048.2
4.6�■
X 1050 3 1�(104E 6 ■1046.3 1♦ *1 046 3
1050 *1.46 8 1046. �♦
61.7
1045 4
x
X 1045 5
Lot area = 14383 sf
House area = 2485 sf
Porch area = 151 sf
Sidewalk area = 26 sf
Driveway area = 1127 sf
Total Impervious Area = 3789 sf
Impervious Coverage = 26.3 %
1049.8
10468
10488
X 1049.7
X 10476
X 1045.6 0
X 1045 6
;047 1
C147 2
1,046 9
1046 9
1046.6f X 1046.4
• ■ �9 �ik3 046
x 1046.2
X 1046.2
X 1046 1
X 1046 6
45 0
X 1044.6
x 1045.1
15811
X 1045.5
44.5
X 1044 3
X 1044.7
9
X 1046.5
X 1044.6
x 1045.6
1042.8
X 1044 81
N 7277117277717 '--
71- /1043.2
• / E518804.55`-
N 172767 94
E 51879E 26x 1042.E
X 1043 4 1041 8
1 1041
1043E
10 ` 11042.4
X 1045.3
1043 0 I
x
X 1045 0 104X4
X 1045.3
X 1044.9
X 1044.7
6
X 1043.8
X 1044.1
X 1041.8
10
1040 4
x
N.172678.14
E: 518784.89
1040.1
1041 5
x
10
J
42.4
N 172645 63
E51877915�.-
1043 1
X 1043 3
31
1041 3
X 1042 6
N
X 1041 7
1040 6 X 1041 3
J.41 039.2
X 1040 6
cp X 1040.4
N 172688.28
038 3 / E 518804.26
// 1039.7
/
�9! 172677.69 1039 2
75187ti[.68 i- .- -i�-
1037.9
039.5 \rg
1040 7
x N
N: 172865.5E 1 ^ M
518803.24 `� / J
1040.5
1042 2
X1042.4
X 1042 s
-7
REVISED 07/13/22 GRADING AS -BUILT
Lowest floor elevation per grading plan : 1046.7
House elevations (Proposed) / As -built
Lowest Floor Elevation :(1047.0) / 1047.2
Top 0f Foundation Elev. :(1055.0) / 1055.1
Garage Slab Elev CO Door :(1054.7) / 1054.9
T.O.F. Elevation ® Lookout:(1050.2) /
We hereby certify to Lennar Corporation that this survey, plan or
report was prepared by me or under my direct supervision, and
that I am a duly licensed Land Surveyor under the laws of the
State of Minnesota, dated 03/30/21.
BY
Signed: //Pioneer Er}gineering, P.A.
Peter J. HaLI flSbn, lrrotegonal Land surveyor
Minnesota License No 42299 email-phawkinson@pioneereng.com
0'
10'
20'
Scale: 1" = 20'
Benchmark:
Top Nut Hydrant
Lots 4-5 Block 2
Elevation = 1052.01
Revisions
1 ) 03-31-21 Stake house
2 )07-13-22 Grading As-butll