HomeMy WebLinkAboutLA204833 - Approved - Stamped Venu Yelamanchili (1)ACDCBGSMMSPSMTB128'-3"84'-1"128'-3"84'-
1
"
19'-
8
"36'-2"15'-
9
"27'-9"PMJBSCALE: 1/16" = 1'COVER PAGESITE PLAN LAYOUTVICINITY MAPVENU YELAMANCHILI - 8.250 kW DC, 6.38 kW ACCUSTOMER INFORMATIONNAME:VENU YELAMANCHILIADDRESS:44.686434, -93.224381APN: 221201004200DESIGNER /CHECKEDDATE:06/18/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:DAKOTA ELECTRICPRN NUMBER:NA18130 GOLDFINCH WAY,LAKEVILLE, MN 55044, USABY: LMT-1SHEET CATALOGINDEX NO.T-1M-1M-2E-1PL-1SSDESCRIPTIONCOVER PAGEMOUNTING DETAILSTRUCTURAL DETAILTHREE LINE DIAGRAMWARNING PLACARDSSPEC SHEET(S)SCOPE OF WORKGENERAL SYSTEM INFORMATION:SYSTEM SIZE:8250W DC, 6380W ACMODULES:(22)MEYER BURGER MB-BLACK-375INVERTER:(22)ENPHASE IQ8PLUS-72-2-USHIGH TEMP: 32°C, LOW TEMP: -26°CAPPLICABLE CODES·FIRE CODE:MNFC 2020·ENERGY CONSERVATION CODE:MNECC 2020·BUILDING CODE:MNBC 2020·RESIDENTIAL CODE:MNRC 2020GENERAL NOTES1.MODULES ARE LISTED UNDER UL 1703 ANDCONFORM TO THE STANDARDS.2.INVERTERS ARE LISTED UNDER UL 1741 ANDCONFORM TO THE STANDARDS.3.DRAWINGS ARE DIAGRAMMATIC, INDICATINGGENERAL ARRANGEMENT OF THE PV SYSTEM ANDTHE ACTUAL SITE CONDITION MIGHT VARY.4.WORKING CLEARANCES AROUND THE NEW PVELECTRICAL EQUIPMENT WILL BE MAINTAINED INACCORDANCE WITH NEC 110.26.5.ALL GROUND WIRING CONNECTED TO THE MAINSERVICE GROUNDING IN MAIN SERVICE PANEL/SERVICE EQUIPMENT.6.ALL CONDUCTORS SHALL BE 600V, 75°CSTANDARD COPPER UNLESS OTHERWISE NOTED.7.WHEN REQUIRED, A LADDER SHALL BE IN PLACEFOR INSPECTION IN COMPLIANCE WITH OSHAREGULATIONS.8.THE SYSTEM WILL NOT BE INTERCONNECTED BYTHE CONTRACTOR UNTIL APPROVAL FROM THELOCAL JURISDICTION AND/OR THE UTILITY.9.ROOF ACCESS POINT SHALL BE LOCATED INAREAS THAT DO NOT REQUIRE THE PLACEMENTOF GROUND LADDERS OVER OPENINGS SUCH ASWINDOWS OR DOORS, AND LOCATED AT STRONGPOINTS OF BUILDING CONSTRUCTION WHERE THEACCESS POINT DOES NOT CONFLICT WITHOVERHEAD OBSTRUCTIONS SUCH AS TREES,WIRES OR SIGNS.10.PV ARRAY COMBINER/JUNCTION BOXPROVIDES TRANSITION FROM ARRAY WIRING TOCONDUIT WIRING·ELECTRIC CODE:NEC 2020 VISIBLE-OPEN TYPE LOCKABLE READILY ACCESSIBLEUTILITY AC DISCONNECT WITHIN 10' OF UTILITY METERTOTAL HOME SQUARE FOOTAGE IS: 2399.55 FT²TOTAL ARRAY SQUARE FOOTAGE IS: 435.38 FT²% COVERED BY SOLAR IS: 18.14%(N) VISIBLE-OPEN TYPE LOCKABLE READILYACCESSIBLE UTILITY AC DISCONNECTWITHIN 10' OF UTILITY METER(N) ENPHASE 4/4C COMBINERPANEL WITH GATEWAY(E) MAIN SERVICE PANEL,200A RATED, 240V(INSIDE GARAGE)(E) GENERAL SERVICE METER WITH DETENT(ENERGY USED BY MEMBER)(UNDERGROUND SERVICE)(N) POLARIS TAP BOX(N) SERVICE METER WITH DETENT(ENERGY SUPPLIED BY MEMBER)CONDUIT RUNJUNCTION BOX(TYPICAL)PHOTOVOLTAIC ARRAYON THE ROOFPROPERTY LINE(E) MAIN HOUSE3' FIRE SETBACK1.5' FIRE SETBACKDRIVEWAYGOL
D
F
I
N
C
H
W
A
Y(N) DER PRODUCTION METER08-01-2022
CUSTOMER INFORMATIONNAME:VENU YELAMANCHILIADDRESS:44.686434, -93.224381APN: 221201004200DESIGNER /CHECKEDDATE:06/18/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:DAKOTA ELECTRICPRN NUMBER:NA18130 GOLDFINCH WAY,LAKEVILLE, MN 55044, USABY: LMM-1SCALE: 1/8" = 1'-0"MOUNTING DETAILINSTALLATION NOTES1.STRUCTURAL ROOF MEMBER LOCATIONS AREESTIMATED AND SHOULD BE LOCATED AND VERIFIEDBY THE CONTRACTOR WHEN LAG BOLT PENETRATIONOR MECHANICAL ATTACHMENT TO THE STRUCTURE ISREQUIRED.2.ROOFTOP PENETRATIONS FOR SOLAR RACKING WILLBE COMPLETED AND SEALED WITH APPROVED SEALANTPER CODE BY A LICENSED CONTRACTOR.3.LAGS MUST HAVE A MINIMUM 2.5" THREADEMBEDMENT INTO THE STRUCTURAL MEMBER.4.ALL PV RACKING ATTACHMENTS SHALL BESTAGGERED BY ROW BETWEEN THE ROOF FRAMINGMEMBERS AS NECESSARY.5.ROOF MOUNTED STANDARD RAIL REQUIRES ONETHERMAL EXPANSION GAP FOR EVERY RUN OF RAILGREATER THAN 40'.6.ALL CONDUCTORS AND CONDUITS ON THE ROOFSHALL BE MINIMUM 7/8" ABOVE THE ROOF SURFACE(INCLUDING CABLES UNDERNEATH MODULES ANDRACKING).7.THE PV INSTALLATION SHALL NOT OBSTRUCT ANYPLUMBING, MECHANICAL OR BUILDING ROOF VENTS.ROOF ACCESS PATHWAYS AND SETBACKS:1204.2.1 SOLAR PHOTOVOLTAIC SYSTEMS FOR GROUPR-3BUILDINGS.SOLAR PHOTOVOLTAIC SYSTEMS FORGROUP R-3 BUILDINGS SHALL COMPLY WITH SECTIONS1204.2.1.1 THROUGH 1204.2.1.3.EXCEPTIONS:1.THESE REQUIREMENTS SHALL NOT APPLY TOSTRUCTURES DESIGNED AND CONSTRUCTED INACCORDANCE WITH THE INTERNATIONAL RESIDENTIALCODE.2.THESE REQUIREMENTS SHALL NOT APPLY TO ROOFSWITH SLOPES OF 2 UNITS VERTICAL IN 12 UNITSHORIZONTAL OR LESS.1204.2.1.1 PATHWAYS TO RIDGE. NOT FEWER THANTWO 36-INCH-WIDE (914 MM) PATHWAYS ON SEPARATEROOF PLANES,FROM LOWEST ROOF EDGE TO RIDGE,SHALL BE PROVIDED ON ALL BUILDINGS. NOT FEWERTHAN ONE PATHWAY SHALL BE PROVIDED ON THESTREET OR DRIVEWAY SIDE OF THE ROOF. FOR EACHROOF PLANE WITH A PHOTOVOLTAIC ARRAY, NOTFEWER THAN ONE 36-INCH-WIDE (914 MM) PATHWAYFROM LOWEST ROOF EDGE TO RIDGE SHALL BEPROVIDED ON THE SAME ROOF PLANE AS THEPHOTOVOLTAIC ARRAY, ON AN ADJACENT ROOF PLANEOR STRADDLING THE SAME AND ADJACENT ROOFPLANES1204.2.1.2 SETBACKS AT RIDGE.FOR PHOTOVOLTAICARRAYS OCCUPYING 33 PERCENT OR LESS OF THE PLANVIEW TOTAL ROOF AREA,A SETBACK OF NOT LESS THAN 18 INCHES (457MM)WIDE IS REQUIRED ON BOTH SIDES OF AHORIZONTAL RIDGE. FOR PHOTOVOLTAIC ARRAYSOCCUPYING MORE THAN 33 PERCENT OF THE PLANVIEW TOTAL ROOF AREA, A SETBACK OF NOT LESSTHAN 36 INCHES (457 MM) WIDE IS REQUIRED ONBOTH SIDES OF A HORIZONTAL RIDGE.1204.2.2 EMERGENCY ESCAPE AND RESCUE OPENINGS.PANELS AND MODULES INSTALLED ON GROUP R-3BUILDINGS SHALL NOT BE PLACED ON THE PORTION OFA ROOF THAT IS BELOW AN EMERGENCY ESCAPE ANDRESCUE OPENING. A PATHWAY OF NOT LESS THAN 36INCHES (914 MM) WIDE SHALL BE PROVIDED TO THEEMERGENCY ESCAPE AND RESCUE OPENING1204.2.1.3 ALTERNATIVE SETBACKS AT RIDGE.WHERE AN AUTOMATIC SPRINKLER SYSTEM ISINSTALLED WITHIN THE DWELLING IN ACCORDANCEWITH SECTION 903.3.1.3, SETBACKS AT THE RIDGESHALL CONFORM TO ONE OF THE FOLLOWING:1.FOR PHOTOVOLTAIC ARRAYS OCCUPYING 66 PERCENTOR LESS OF THE PLAN VIEW TOTAL ROOF AREA, ASETBACK OF NOT LESS THAN 18 INCHES (457 MM)WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTALRIDGE.2.FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN66 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, ASETBACK OF NOT LESS THAN 36 INCHES (914 MM)WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTALRIDGEAERIAL VIEWSITE INFORMATION - WIND SPEED: 115 MPH AND SNOW LOAD: 50 PSFSR. NOARRAYTILTAZIMUTHNO. OFMODULESARRAYAREA(SQ. FT.)ROOF TYPE ATTACHMENTROOFEXPOSUREFRAME TYPEFRAMESIZEFRAMESPACINGMAX RAILSPANOVERHANGMP-01 26 29222435.38COMPOSITIONSHINGLEUNIRAC ROOFTECH RT-MINIATTICTRUSS2" x 4"2'-0" 4'-0" 2'-0"2" x 4" TRUSS @ 2'-0" O.C. SPACINGNOTE:PENETRATIONS ARE STAGGERED(55) UNIRAC ROOF TECH RT-MINIATTACHMENT @48" O.C.(N) UNIRAC RAILARRAY MP-013'3'
4'08-01-2022
6"CUSTOMER INFORMATIONNAME:VENU YELAMANCHILIADDRESS:44.686434, -93.224381APN: 221201004200DESIGNER /CHECKEDDATE:06/18/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:DAKOTA ELECTRICPRN NUMBER:NA18130 GOLDFINCH WAY,LAKEVILLE, MN 55044, USABY: LMM-2ATTACHMENT DETAILMODULES DATAMEYER BURGER MB-BLACK-375MODULE DIMS69.57"x40.98"x1.38"1ATTACHMENT DETAILM-2SCALE: NTSSEE (2/PV-5) FORENLARGED VIEW(E)COMP SHINGLE ROOF(N)SOLAR MODULE(E)2" x 4" TRUSS @ 2'-0" O.CSOLAR MOUNTUNIRAC RAILM-2SCALE: NTSATTACHMENT DETAIL (Top view)M-2SCALE: NTS2GROUNDING END/MID CLAMP(N)SOLAR MODULE5/16"x4" SS LAG BOLT WITH MIN3" THREAD EMBEDMENT, SEALEDPENETRATIONW5/16" OR M8 HEX BOLTSOLAR MOUNTUNIRAC RAIL(E)COMP SHINGLE ROOFRT-MINIRT-MINIUNIRAC MODULECLAMP w/ 516" BOLTAND LOCK WASHERBOTTOM MOUNTING CLIPSTRUCTURAL DETAIL(E)2" x 4" TRUSS @ 2'-0" O.CIRON RIDGE L- FOOTUNIRAC PRO SERIES CLAMPIRON RIDGE L- FOOT08-01-2022
2LOADLINEGL1L2NL1L2NBONDED3ML2L1TO UTILITY GRIDNLINELOADML1L2NLINELOADL1L1L2L2BY-PASS LEVER(N) SERVICE METER WITHDETENT(ENERGY SUPPLIED BYMEMBER)(E) GENERAL SERVICEMETER WITH DETENT(ENERGY USED BY MEMBER)1-PHASE, 3-WIRE, 120V/240V55BY-PASS LEVERGNNEW NEMA 3RRATED TAP BOXLINE SIDEINTERCONNECTIONUSING POLARISCONNECTORGBONDEDEXISTING GROUNDINGELECTRODE SYSTEMTO EARTHREF. NEC 250.52,250.53(A)BONDED(E) MAIN SERVICE PANEL200A RATED, 240V(E) MAIN BREAKER TOHOUSE 240 V, 200A/2P(TOP FED)LINE SIDEINTERCONNECTIONAT MAIN PANELPER ART. 705.12(A)(INSIDE GARAGE)(UNDERGROUNDSERVICE)(N) UTILITY AC DISCONNECT: VISIBLE-OPEN TYPE LOCKABLEREADILY ACCESSIBLE60A FUSED, (2) 40A FUSES,240V NEMA 3R, UL LISTEDEATON DG222NRBGL1L2NGL1L2NMGL1L2NLINELOADL1L1L2L2(N)DER PRODUCTION METER NEMA 3R, UL LISTED120V/240V 200A RATED WITH BYPASS1-PHASE,3-WIRE(U4801-XL-5T9)2GNJUNCTION BOX600 V, NEMA 3UL LISTED(2) ENPHASE Q CABLES20A/2PL2L1111 MICROINVERTERS IN BRANCH CIRCUIT 111 MICROINVERTERS IN BRANCH CIRCUIT 2G415A/2P20A/2PL2L1PER MANUFACTURERSPECIFICATIONS, EITHER10A OR 15A BREAKER ISSUITABLE FOR USEMEYER BURGER MB-BLACK-375ENPHASE IQ8PLUS-72-2-USMICROINVERTERS ONE UNDEREACH PANEL(240V)ENPHASE IQ COMBINER 4/4C WITH ENPHASE IQ GATEWAY ,(2) 20A / 240VAC CIRCUITBREAKER 125A RATEDWIRELESSCOMMSIQ GATEWAYCUSTOMER INFORMATIONNAME:VENU YELAMANCHILIADDRESS:44.686434, -93.224381APN: 221201004200DESIGNER /CHECKEDDATE:06/18/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:DAKOTA ELECTRICPRN NUMBER:NA18130 GOLDFINCH WAY,LAKEVILLE, MN 55044, USABY: LME-1THREE LINE DIAGRAMELECTRICAL CALCULATIONS: DC SYSTEM SIZE - 8250W, AC SYSTEM SIZE - 6380WMODULE SPECIFICATIONMODELMODULE POWER @ STCOPEN CIRCUIT VOLTAGE:VocMAX POWER VOLTAGE:VmpSHORT CIRCUIT VOLTAGE:IscMAX POWER CURRENT:ImpMEYER BURGERMB-BLACK-375375W44.5V38.0V10.6A9.9AELECTRICAL CALCULATIONSDC WIRE SIZING CALCULATIONS BASED OF FOLLOWING EQUATIONS>>· REQUIRED CONDUCTOR AMPACITY: 125% PER 690.8(A)(1) X Isc(A) X #OFPARALLEL STRINGS = MAX CURRENT PER 690.8(A)(1) X 125% PER690.8(B)(2)(a)=MAX CURRENT PER 690.8(B)(2)(a)· CORRECTED AMPACITY CALCULATIONS:AMPACITY X TEMPERATURE DERATEFACTOR X CONDUIT FILL DERATE = DERATED CONDUCTOR AMPACITY· DERATED CONDUCTOR AMPACITY CHECK: MAX CURRENT PER 690.8(B)(2)(2) <DERATED CONDUCTOR AMPACITYAC WIRE SIZING CALCULATIONS BASED OF FOLLOWING EQUATIONS >>· REQUIRED CONDUCTOR AMPACITY: INVERTER OUTPUT CURRENT X #OFINVERTERSXMAX CURRENT PER 690.8(A)(3)X125% PER 690.8(B)(2)(A)· CORRECTED AMPACITY CALCULATIONS:AMPACITY X TEMPERATURE DERATEFACTOR X CONDUIT FILL DERATE = DERATED CONDUCTOR AMPACITY· DERATED CONDUCTOR AMPACITY CHECK: MAX CURRENT PER 690.8(B)(2)(2) <DERATED CONDUCTOR AMPACITYAC WIRE CALCULATIONS:- MATERIAL:COPPER & TEMPERATURE RATING:90°CTAG IDREQUIRED CONDUCTOR AMPACITYAC WIRE CALCULATIONS:- MATERIAL:COPPER & TEMPERATURE RATING:90°CTAG IDREQUIRED CONDUCTOR AMPACITYCORRECTED AMPACITY CALCULATIONDERATED CONDUCTOR AMPACITY CHECK<CORRECTED AMPACITY CALCULATION<ELECTRICAL NOTES1.CONDUCTORS EXPOSED TO SUNLIGHTSHALL BE LISTED AS SUNLIGHTRESISTANT PER NEC 310.10(D).2.CONDUCTORS EXPOSED TO WETLOCATIONS SHALL BE SUITABLE FOR USEIN WET LOCATIONS PER NEC 310.10(C).3.MAXIMUM DC/AC VOLTAGE DROP SHALLBE NO MORE THAN 2%.4.ALL CONDUCTORS SHALL BE IN CONDUITUNLESS OTHERWISE NOTED.5.BREAKER/FUSE SIZES CONFORMS TONEC 240.6 CODE SECTION.6.AC GROUNDING ELECTRODECONDUCTOR SIZED PER NEC 250.66.7.AMBIENT TEMPERATURE CORRECTIONFACTOR IS BASED ON NEC 690.31(C).8.AMBIENT TEMPERATURE ADJUSTMENTFACTOR IS BASED ON NEC 310.15(B)(2).9.MAX. SYSTEM VOLTAGE CORRECTION ISPER NEC 690.7.10.CONDUCTORS ARE SIZED PER WIREAMPACITY TABLE NEC 310.15(B)(16).1 1.21 11XX1=40A0.7613.31AX1.25=XX0.8=24.32A221.21X=1.25X=224.32ADERATED CONDUCTOR AMPACITY CHECKOCPD CALCULATIONS:INVERTER OVERCURRENT PROTECTION= INVERTER O/P I X CONTINUOUS LOAD(1.25)=22x1.25x1.21 = 33.28A => PV BREAKER = 40ATOTAL REQUIRED PV BREAKER SIZE/FUSED SIZE=>40A PV BREAKERMAIN PANEL RATING: 200A, MAIN REAKER RATING: 200AINVERTER SPECIFICATIONSMODELPOWER RATINGMAX OUTPUT CURRENTCEC WEIGHTED EFFICIENCYMAX INPUT CURRENTMAX DC VOLTAGEENPHASEIQ8PLUS-72-2-US(240V)235W-440W1.21A97%15A PER STRING60V MAXMAX OUTPUT POWER290 VA (SINGLE INVERTER)16.64A16.64A26.62A33.28A33.28AMETER:1ND90309820TAG ID123CONDUIT SIZE1" EMT OR EQUIV(2) 6 AWG THHN/THWN-2CONDUCTOR(4) 10 AWG THHN/THWN-2NEUTRALNONE(1) 6 AWG THHN/THWN-2GROUND1" EMT OR EQUIV4(1) 10 AWG THHN/THWN-2(1) 10 AWG THHN/THWN-2(1) 6 AWG BARE CU3/4" EMT OR EQUIV(2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2NONEVISIBLE-OPEN, LOCKABLE AND READILYACCESSIBLE AC DISCONNECT IS LOCATEDWITHIN 10 FEET OF THE UTILITY METERNEUTRAL AND GROUND TO BE BONDEDAT AC DISCONNECT TO SUPPLY SIDETAP; AC DISCONNECT ACTS ASSERVICE EQUIPMENT33.6A35X0.96X1=5(2) 2/0 AWG THHN/THWN-2(1) 2/0 AWG THHN/THWN-22" EMT OR EQUIVNONEDISTANCE BETWEEN EQUIPMENT TAP BOX TO AC DISCONNECT6"DISTANCE6"6"GENERAL SERVICE METER TO SERVICE METER AC DISCONNECT TO PRODUCTION METERSERVICE METER TO TAP BOX6"PRODUCTION METER TO COMBINER PANEL6"<221.21X=1.25X=326.62A33.28A33.28A62.4A65X0.96X1=62.4A33.6ACONDUIT SCHEDULE
ACDCBGSMMSPSMTBPMJB CUSTOMER INFORMATIONNAME:VENU YELAMANCHILIADDRESS:44.686434, -93.224381APN: 221201004200DESIGNER /CHECKEDDATE:06/18/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:DAKOTA ELECTRICPRN NUMBER:NA18130 GOLDFINCH WAY,LAKEVILLE, MN 55044, USABY: LMPL-1 WARNING PLACARDALL PLACARDS SHALL BE OF WEATHER PROOF CONSTRUCTION, BACKGROUND ON ALL PLACARDS SHALL BERED WITH WHITE LETTERING U.O.N.PLACARD SHALL BE MOUNTED DIRECTLY ON THE EXISTING UTILITY ELECTRICAL SERVICE.FASTENERS APPROVED BY THE LOCAL JURISDICTIONPOWER TO THIS BUILDING IS ALSOSUPPLIED FROM THE FOLLOWINGSOURCES WITH DISCONNECTS LOCATEDAS SHOWNWARNING:!SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWNTURN RAPID SHUTDOWNSWITCH TO THE"OFF" POSITION TOSHUT DOWN THE PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYPLACED ON INVERTERSOLAR ELECTRIC PV PANELS WARNINGELECTRIC SHOCK HAZARDTHE DC CONDUCTORS OF THIS PHOTOVOLTAICSYSTEM ARE UNGROUNDED AND MAY BEENERGIZEDLABEL LOCATIONDC DISCONNECT,INVERTER[PER CODE: NEC 690.41)][To be used when inverter is ungrounded]WARNINGELECTRIC SHOCK HAZARDTERMINALS ON BOTH LINE AND LOAD SIDES MAYBE ENERGIZED IN THE OPEN POSITIONDC VOLTAGE IS ALWAYS PRESENT WHEN SOLARMODULES ARE EXPOSED TO SUNLIGHTLABEL LOCATIONAC DISCONNECT,POINT OF INTERCONNECTION[PER CODE: NEC 690.13(B)] WARNINGELECTRIC SHOCK HAZARDTERMINALS ON BOTH LINE AND LOAD SIDESMAY BE ENERGIZED IN THE OPEN POSITIONLABEL LOCATIONAC DISCONNECT,POINT OF INTERCONNECTION[PER CODE: NEC 690.13(B)]WARNING-ELECTRIC SHOCK HAZARDNO USER SERVICEABLE PARTS INSIDECONTACT AUTHORIZED SERVICEPROVIDE FOR ASSISTANCELABEL LOCATIONINVERTER, JUNCTION BOXES(ROOF),AC DISCONNECT[PER CODE: NEC 690.13]WARNING:PHOTOVOLTAICPOWER SOURCELABEL LOCATIONCONDUIT, COMBINER BOX[PER CODE: NEC690.31(G)(3)]CAUTION: SOLAR ELECTRICSYSTEM CONNECTEDLABEL LOCATIONWEATHER RESISTANT MATERIAL, DURABLE ADHESDIVE,UL969 AS STANDARD TO WEATHER RATING (UL LISTINGOF MARKINGS NOT REQUIRED), MIN 38" LETTER HEIGHTARIAL OR SIMILAR FONT NON-BOLD,PLACED WITHINTHE MAIN SERVICE DISCONNECT,PLACED ON THEOUTSIDE OF THE COVER WHEN DISCONNECT ISOPERATED WITH THE SERVICE PANEL CLOSED.(PER CODE: NEC690.15 ,690.13(B))RAPID SHUTDOWNSWITCH FOR SOLAR PVSYSTEMLABEL LOCATIONINVERTER[PER CODE: NEC 690.56(C)(3)]PHOTOVOLTAIC SYSTEM AC DISCONNECT SWITCHRATED AC OPERATING CURRENTAC NOMINAL OPERATING VOLTAGELABEL LOCATIONAC DISCONNECT , POINT OF INTERCONNECTION[PER CODE: NEC 690.54]WARNINGPOWER SOURCE OUTPUTCONNECTIONDO NOT RELOCATE THISOVER-CURRENT DEVICELABEL LOCATIONPOINT OF INTERCONNECTION(PER CODE: NEC 705.12(b)(2)(3)(b)[ Not Required if Panel board is rated not less than sum ofampere ratings of all overcurrent devices supplying it]CAUTION: SOLAR CIRCUITLABEL LOCATIONMARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC CONDUIT,RACEWAYS, ENCLOSURES AND CABLE ASSEMBLES AT LEAST EVERY10 FT, AT TURNS AND ABOVE/BELOW PENETRATIONS AND ALLCOMBINER/JUNCTION BOXES.(PER CODE: IFC605.11.1.4)SOLAR DISCONNECTLABEL LOCATIONDISCONNECT, POINT OF INTERCONNECTION[PER CODE: NEC690.13(B)]WARNINGDUAL POWER SOURCE SECONDSOURCE IS PHOTOVOLTAICSYSTEMLABEL LOCATIONPOINT OF INTERCONNECTION[PER CODE: NEC705.12(D)(4)]240AMPS ACVAC!!!!SOLAR PHOTOVOLTAICROOF MOUNTED(E) MAIN SERVICE PANEL(INSIDE GARAGE)PHOTOVOLTAICAC DISCONNECTAT EACH AC DISCONNECT33.28(N) AC DISCONNECT(N) 4/4C COMBINER BOXWARNING PLACARDS(E) GENERAL SERVICEMETER WITH DETENT(ENERGY USED BY MEMBER)(UNDERGROUND SERVICE)(N) POLARIS TAP BOX(N) SERVICE METER WITH DETENT(ENERGY SUPPLIED BY MEMBER)(N) DER PRODUCTION METER
CUSTOMER INFORMATIONNAME:VENU YELAMANCHILIADDRESS:44.686434, -93.224381APN: 221201004200DESIGNER /CHECKEDDATE:06/18/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:DAKOTA ELECTRICPRN NUMBER:NA18130 GOLDFINCH WAY,LAKEVILLE, MN 55044, USABY: LMSS-1 SPEC SHEETMODULE SPEC SHEET
CUSTOMER INFORMATIONNAME:VENU YELAMANCHILIADDRESS:44.686434, -93.224381APN: 221201004200DESIGNER /CHECKEDDATE:06/18/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:DAKOTA ELECTRICPRN NUMBER:NA18130 GOLDFINCH WAY,LAKEVILLE, MN 55044, USABY: LMSS-2 SPEC SHEETINVERTER SPEC SHEET
CUSTOMER INFORMATIONNAME:VENU YELAMANCHILIADDRESS:44.686434, -93.224381APN: 221201004200DESIGNER /CHECKEDDATE:06/18/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:DAKOTA ELECTRICPRN NUMBER:NA18130 GOLDFINCH WAY,LAKEVILLE, MN 55044, USABY: LMSS-3 SPEC SHEETCOMBINER BOXSPEC SHEET
CUSTOMER INFORMATIONNAME:VENU YELAMANCHILIADDRESS:44.686434, -93.224381APN: 221201004200DESIGNER /CHECKEDDATE:06/18/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:DAKOTA ELECTRICPRN NUMBER:NA18130 GOLDFINCH WAY,LAKEVILLE, MN 55044, USABY: LMSS-4 SPEC SHEETMOUNT SPEC SHEET
CUSTOMER INFORMATIONNAME:VENU YELAMANCHILIADDRESS:44.686434, -93.224381APN: 221201004200DESIGNER /CHECKEDDATE:06/18/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:DAKOTA ELECTRICPRN NUMBER:NA18130 GOLDFINCH WAY,LAKEVILLE, MN 55044, USABY: LMSS-5 SPEC SHEETMOUNT SPEC SHEET
CUSTOMER INFORMATIONNAME:VENU YELAMANCHILIADDRESS:44.686434, -93.224381APN: 221201004200DESIGNER /CHECKEDDATE:06/18/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:DAKOTA ELECTRICPRN NUMBER:NA18130 GOLDFINCH WAY,LAKEVILLE, MN 55044, USABY: LMSS-6 SPEC SHEETMOUNT SPEC SHEET
CUSTOMER INFORMATIONNAME:VENU YELAMANCHILIADDRESS:44.686434, -93.224381APN: 221201004200DESIGNER /CHECKEDDATE:06/18/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:DAKOTA ELECTRICPRN NUMBER:NA18130 GOLDFINCH WAY,LAKEVILLE, MN 55044, USABY: LMSS-7 SPEC SHEETMOUNT SPEC SHEET
CUSTOMER INFORMATIONNAME:VENU YELAMANCHILIADDRESS:44.686434, -93.224381APN: 221201004200DESIGNER /CHECKEDDATE:06/18/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:DAKOTA ELECTRICPRN NUMBER:NA18130 GOLDFINCH WAY,LAKEVILLE, MN 55044, USABY: LMSS-8 SPEC SHEETMOUNT SPEC SHEET
CUSTOMER INFORMATIONNAME:VENU YELAMANCHILIADDRESS:44.686434, -93.224381APN: 221201004200DESIGNER /CHECKEDDATE:06/18/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:DAKOTA ELECTRICPRN NUMBER:NA18130 GOLDFINCH WAY,LAKEVILLE, MN 55044, USABY: LMSS-9 SPEC SHEETMOUNT SPEC SHEET
CUSTOMER INFORMATIONNAME:VENU YELAMANCHILIADDRESS:44.686434, -93.224381APN: 221201004200DESIGNER /CHECKEDDATE:06/18/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:DAKOTA ELECTRICPRN NUMBER:NA18130 GOLDFINCH WAY,LAKEVILLE, MN 55044, USABY: LMSS-10 SPEC SHEETMOUNT SPEC SHEET
CUSTOMER INFORMATIONNAME:VENU YELAMANCHILIADDRESS:44.686434, -93.224381APN: 221201004200DESIGNER /CHECKEDDATE:06/18/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:DAKOTA ELECTRICPRN NUMBER:NA18130 GOLDFINCH WAY,LAKEVILLE, MN 55044, USABY: LMSS-11 SPEC SHEETAC DISCONNECT &JUNCTION BOX SPEC SHEET
CUSTOMER INFORMATIONNAME:VENU YELAMANCHILIADDRESS:44.686434, -93.224381APN: 221201004200DESIGNER /CHECKEDDATE:06/18/2022SCALE:AS NOTEDPAPER SIZE:17"X11"REV:AAHJ: CITY OF LAKEVILLEUTILITY:DAKOTA ELECTRICPRN NUMBER:NA18130 GOLDFINCH WAY,LAKEVILLE, MN 55044, USABY: LMSS-12 SPEC SHEETPRODUCTION METER SPEC SHEET