LA203617 - Approved plans
:(676+25( '(6,*1(1*,1((563& 100 GREAT OAKS BLVD. ͿSUITE 115 ALBANY Ϳ NEW YORK Ϳ 12203 :HVW6KRUH'HVLJQ(QJLQHHUVۅ*UHDW2DNV%OYGۅ6XLWHۅ$OEDQ\1<ۅ 6XEMHFW .DQQHNDQWL5HVLGHQFH *UHHQZRRG&W /DNHYLOOH01 7R:KRP,W0D\&RQFHUQ 7KHIROORZLQJUHIHUHQFHVWKH.DQQHNDQWL5HVLGHQFHLQ/DNHYLOOH01 ([LVWLQJURRIIUDPLQJ 5RRIV 3UHIDEULFDWHGHQJLQHHUHGZRRGWUXVVLV[ [DW´RF7KLVH[LVWLQJVWUXFWXUH LVFDSDEOHWRVXSSRUWDOOWKHORDGVLQGLFDWHGEHORZIRUWKLVSKRWRYROWDLFSURMHFW 5RRI/RDGLQJ SVIGHDGORDGPRGXOHVSOXVPRXQWLQJKDUGZDUH SVIJURXQGVQRZORDG SVIURRIPDWHULDOVSVI[SVIVKHDWKLQJSVIDVSKDOWVKLQJOHV ([SRVXUH&DWHJRU\%PSKZLQGVHF 7KLVLQVWDOODWLRQGHVLJQZLOOEHLQJHQHUDOFRQIRUPDQFHWRWKHPDQXIDFWXUHU¶VVSHFLILFDWLRQVDQGFRPSOLHV ZLWKDOODSSOLFDEOHODZVFRGHVDQGRUGLQDQFHVVSHFLILFDOO\WKH,QWHUQDWLRQDO%XLOGLQJ&RGH,%& DQG,QWHUQDWLRQDO5HVLGHQWLDO&RGH,5&LQFOXGLQJDOO01UHJXODWLRQVDQGDPHQGPHQWV7KHVSDFLQJ DQGIDVWHQLQJRIWKHPRXQWLQJEUDFNHWVLVWRKDYHDPD[LPXPRI´RFVSDQEHWZHHQPRXQWLQJEUDFNHWV VWDJJHUHGDQGVHFXUHGXVLQJ´GLDPHWHUFRUURVLYHUHVLVWDQWVWHHOODJEROWVDQGD´HPEHG7LOWXS V\VWHPLQVWDOOHGSHUPDQXIDFWXUHUVSHFLILFDWLRQVDQGUHFRPPHQGDWLRQV 7KDQN\RX :HVWVKRUH'HVLJQ(QJLQHHUV -RKQ(LEHUW1LFRODV1LWWL3( 3URMHFW&RRUGLQDWRU3UHVLGHQW 7R $OO(QHUJ\6RODU )URQW6W &KLFRSHH0$ 'DWH-XQH 5HI LICENSED PROFESSIONAL ENGINEERNICOLAS A . NI TTISTATE OF M I N NE SO TA54597 EXP. 6/30/2022 ~143.72'~154 . 6 2 '~170.14'~41.37'16'-7"6'-7" 17'- 4 "45'-3"PVMACDCBUMACDMSPSITE PLAN WITH ROOF PLANREVDATEDESCRIPTIONVERSIONUR06/16/2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-1 PROJECT NAMEPAVAN KANNIKANTI 20964 GREENWOOD CT, MINNEAPOLIS, MN 55044 USA APN# 221674007180 UTILITY: XCEL ENERGY AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"ALL ENERGY SOLAR1264 ENERGY LNST PAUL, MN 55108TEL: (800) 620-3370Email:info@allenergysolar.comNEW ELECTRIC SERVICEACCOUNT NUMBER :51-0012439378-9PREMISE NUMBER : 304516119METER NUMBER : 17778890CASE NUMBER : 4982167UTILITY PHONE NUMBER FORSUTDOWN :1-800-628-2121TBD NEW CONSTRUCTION CUSTOMER PHONE NUMBER: (603) 867-8066 INSPECTOR PHONE NUMBER 507-381-1791INSPECTOR -N/ASITE PLAN WITHROOF PLAN1SCALE: 1/16" = 1'-0"NOTE:A. ALL ELECTRICAL EQUIPMENT, INVERTERS,DISCONNECTS, MAIN SERVICE PANELS, ETC.SHALL NOT BE INSTALLED WITHIN 3’ OF THEGAS METERS’ SUPPLY OR DEMAND PIPING.NOTES:1. LOCATION OF SERVICE PANEL AND ELECTRICALEQUIPMENT ARE SHOWN. FINAL LOCATION MAY CHANGE.2. LOCATION OF SERVICE PANEL AND ADDITIONALELECTRICAL EQUIPMENT NOT DRAWN TO SCALE.3. PV INTERCONNECTION IS A SECONDARYINTERCONNECTION4. AC DISCONNECT AND PRODUCTION METER IN READILYACCESSIBLE LOCATION WITHIN 10' OF MAIN READILYSERVICE METER/BI-DIRECTIONAL METER. 24/7UNESCORTED KEYLESS ACCESS TO BE PROVIDED FORUTILITY AC DISCONNECT, PV PRODUCTION METER, &BI-DIRECTIONAL METER.5. PV EQUIPMENT SHALL BE INSTALLED IN ACCORDANCEWITH NEC 690 AND POSTED WITH APPLICABLEWARNINGS, SIGNAGE, AND PLAQUES PER NEC 705-10,690-17, & 690-64 (b)(5).LABELS LOCATED ON PV PRODUCTION METER,BI- DIRECTIONAL METER, AC DISCONNECT (S),INVERTER(S), AND APPROPRIATE LABELS ON MAINELECTRIC SERVICE. ALL LABELS ARE PERMANENT,WEATHERPROOF, AND DURABLE THERE ARE NOCLEARANCE ISSUES DUE TO OVERHEAD POWERLINES.DISTANCESSOLAR PANELS - INVERTER: 5' MAXINVERTER'S - IQ COMBINER PANEL : 50'IQ COMBINER PANEL - UTILITY AC DISCONNECT: 2'UTILITY AC DISCONNECT - PV PRODUCTION METER: 2'PV PRODUCTION METER - PV SERVICE DISCONNECT: 2'PV SERVICE DISCONNECT - MAIN ELECTRIC SERVICE: 2' MAIN ELECTRIC SERVICE - BI-DIRECTIONAL METER: 2'OPEN VISIBLE, LOCKABLE, LABELEDAC DISCONNECT LOCATED WITHIN10' OF UTILITY METERINVERTER SPECIFICATIONSMANUFACTURER / MODEL #ENPHASE IQ7A-72-2-USNOMINAL OUTPUT VOLTAGE240 VACNOMINAL OUTPUT CURRENT1.45A(25) REC SOLAR REC400AA PURE BLACK (400W) MODULES(25) ENPHASE IQ7A-72-2-US MICRO-INVERTERS(01) BRANCHES OF 09 MODULES &(02)BRANCHES OF 08 MODULES CONNECTED IN PARALLEL(E) 200A MAIN SERVICE PANELWITH (E) 200A MAIN BREAKER(INSIDE)(E) UTILITY METER(N) 60A SERVICE FUSED AC DISCONNECT(N) XCEL ENERGY PRODUCTION METER120/240V, 200A WITH BYPASS 1-PHASE, 3-WIRE(N) 60A UTILITY AC DISCONNECT VISIBLE-OPENTYPE, LOCKABLE, READILY ACCESSIBLE(N) ENPHASE IQ COMBINER 3ROOF #1(25) REC SOLAR REC400AA PUREBLACK (400W) MODULESEXISTINGDRIVEWAYTW O - S T O R Y HO U S E PROPERTY LINEPRO P E R T Y L I N E PROPERTY LINEGREENWOOD CT 10' MAX 1'-6 " 34'- 1 " 10'- 5 "3'-6"18'-1"6'-11"PVMACDCBUMACDMSPREVDATEDESCRIPTIONVERSIONUR06/16/2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-2 PROJECT NAMEPAVAN KANNIKANTI 20964 GREENWOOD CT, MINNEAPOLIS, MN 55044 USA APN# 221674007180 UTILITY: XCEL ENERGY AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"ALL ENERGY SOLAR1264 ENERGY LNST PAUL, MN 55108TEL: (800) 620-3370Email:info@allenergysolar.comNEW ELECTRIC SERVICEACCOUNT NUMBER :51-0012439378-9PREMISE NUMBER : 304516119METER NUMBER : 17778890CASE NUMBER : 4982167UTILITY PHONE NUMBER FORSUTDOWN :1-800-628-2121TBD NEW CONSTRUCTION CUSTOMER PHONE NUMBER: (603) 867-8066 INSPECTOR PHONE NUMBER 507-381-1791INSPECTOR -N/AROOF PLAN WITHMODULESROOF PLAN WITH MODULESSCALE: 3/32" = 1'-0"1MODULE TYPE, DIMENSIONS & WEIGHTNUMBER OF MODULES = 25 MODULESMODULE TYPE = REC SOLAR REC400AA PURE BLACK (400W) MODULESMODULE WEIGHT = 45.0 LBS / 20.5 KG.MODULE DIMENSIONS = 71.7"X 40.0" = 19.92 SFUNIT WEIGHT OF ARRAY = 2.26 PSFLEGENDUM- UTILITY METERMSP- MAIN SERVICE PANELACD- AC DISCONNECTCB- COMBINER BOXPVM- PRODUCTION METER- VENT, ATTIC FAN(ROOF OBSTRUCTION)- ROOF ATTACHMENT-TRUSSES3'-0"36" FIRE PATHWAY18"18" FIRE PATHWAYBILL OF MATERIALSEQUIPMENT QTYDESCRIPTIONRAIL13 SNAPNRACK UR-40 RAILSPLICE08RAIL SPLICEMID CLAMP44 MODULE MID CLAMPEND CLAMP12 MODULE END CLAMPATTACHMENT49SNAPNRACK SPEEDSEAL DECKFOOTATTACHMENTSGROUNDING LUG 03 GROUNDING LUGR324.6.2 - PROVING ARRAYS TAKELESS THAN 33% OF TOTAL ROOFAREA.WHEN THE ARRAYS TAKE LESSTHAN 33% WE CAN JUSTIFY AN 18"SETBACK ON BOTH SIDES OF THERIDGE. WHEN IT TAKES MORE THAN33% OF THE ROOF AREA WE MUSTUSE A 3' SETBACKS AT THE RIDGE.TOTAL ROOF AREA:2684.19 sqftAREA OF ARRAYS:71.7"X 40.0" ( PANEL DIMENSIONS)71.7"X 40.0" = 19.92 sqft (PER PANEL)19.92 sqftpanel X 25 panels = 497.92 sqft(TOTAL PANEL AREA)PERCENTAGE OF TOTAL ROOF AREA:(497.92 sqft / 2684.19 sqft)(100)= 18.55%∴ THE PANELS USE 18.55% OFTHE TOTAL ROOF AREAROOF DESCRIPTIONROOF TYPECOMP SHINGLE ROOFROOFROOFTILTAZIMUTHTRUSSESSIZETRUSSESSPACING#128° 118°2"x4" 24" O.C.71.7"40.0"PHOTOVOLTAIC MODULESREC SOLAR REC400AA PUREBLACK (400W)REAR YARDNOTE: ACTUAL ROOF CONDITIONS AND TRUSSES (OR SEAM)LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S)INSTALLATION GUIDELINES AND ENGINEERED SPANS FORATTACHMENTS(E) 200A MAIN SERVICE PANELWITH (E) 200A MAIN BREAKER(INSIDE)(E) UTILITY METER(N) 60A SERVICE FUSED AC DISCONNECT(N) XCEL ENERGY PRODUCTION METER120/240V, 200A WITH BYPASS 1-PHASE, 3-WIRE(N) 60A UTILITY AC DISCONNECT VISIBLE-OPENTYPE, LOCKABLE, READILY ACCESSIBLEROOF #1(25) REC SOLAR REC400AA PUREBLACK (400W) MODULES(N) ENPHASE IQ COMBINER 3(E) COMP SHINGLE ROOF (TYP.)(N) SNAPNRACK UR-40 RAIL(E) 2"X4" TRUSSES @ 24" O.C. (TYP.)(N) (49) SNAPNRACK SPEEDSEAL DECKFOOTATTACHMENTS SPACED AT 48" O.C.18" F I R E P A T H W A Y 18" F I R E P A T H W A Y 36" FIRE PATHWAY36" FIRE PATHWAYGREENWOOD CTFRONT YARD RE A R Y A R D 10' MAX REVDATEDESCRIPTIONVERSIONUR06/16/2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-3 PROJECT NAMEPAVAN KANNIKANTI 20964 GREENWOOD CT, MINNEAPOLIS, MN 55044 USA APN# 221674007180 UTILITY: XCEL ENERGY AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"ALL ENERGY SOLAR1264 ENERGY LNST PAUL, MN 55108TEL: (800) 620-3370Email:info@allenergysolar.comNEW ELECTRIC SERVICEACCOUNT NUMBER :51-0012439378-9PREMISE NUMBER : 304516119METER NUMBER : 17778890CASE NUMBER : 4982167UTILITY PHONE NUMBER FORSUTDOWN :1-800-628-2121TBD NEW CONSTRUCTION CUSTOMER PHONE NUMBER: (603) 867-8066 INSPECTOR PHONE NUMBER 507-381-1791INSPECTOR -N/AATTACHMENTDETAILSNAPNRACK UR SPEEDSEAL DECKFOOT FOR COMPOSTION ROOFMOUNTING ONTO WOOD DECKING5REFER TO SNAPNRACK ENGINEERING CHARTS FOR APPLICABLERAIL SPANS. "BIN" NUMBER ON CHART SHOULD MATCH "BIN"NUMBER ON THIS DRAWING(X4) #14 FULLY THREADED WOOD SCREWS, S.S. MUST EMBEDFULLY INTO WOOD DECKREFER TO SNAPNRACK INSTALLATION MANUAL FOR 5HARDWARE TORQUE SPECIFICATIONS16"∴RAIL CAN MOUNT ON EITHER SIDE OF SPEEDSEAL DECKFOOT.SPEEDSEAL DECKFOOT CAN MOUNT UP, DOWN, OR ACROSS THESLOPE OF THE ROOFFOR ADDITIONAL LEVELING DETAILS, REFER TO SNAPNRACKDETAIL DRAWING "SNR-DC-00447 ULTRA RAIL, COMPONENTDETAIL, ULTRA RAIL LEVELING SPACER"SNAPNRACK, SPEEDSEALDECKFOOT BASE, SEALINGSNAPNRACK, UR MOUNTTHRUSNAPNRACK, UR MOUNTTAPPEDEXPLODEDSNAPNRACK, ULTRA RAILTOPCOMP SHINGLE ROOFING, TYP.3.86016"∴-18 X 13COIL SPRING FOR 34" BOLT,SERRATED FLANGE, S.S.8"∴BOLT, S.S. (OPTIONAL)5.200MODULE HEIGHT, MAX:UR-40 = 438"COMP SHINGLE ROOFING, TYP.ROOF DECKING, TYP.SCREW HEIGHTOFF ROOF:916"112"158"UR-40 RAILFOR USE WITH SNAPNRACK ULTRA SERIES RAILSMINIMUM DECK THICKNESS:PLYWOOD:15/32"ATTACHMENT DETAILSECTION VIEWOSB: 716"(4X) #14 FULLY THREADEDWOOD SCREW. S.S. MUST EMBEDFULLY INTO WOOD DECKINSTALLATION OVERVIEWROOF DECKING, TYP. 20'-0"24'-0"32'-7"REVDATEDESCRIPTIONVERSIONUR06/16/2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-4 PROJECT NAMEPAVAN KANNIKANTI 20964 GREENWOOD CT, MINNEAPOLIS, MN 55044 USA APN# 221674007180 UTILITY: XCEL ENERGY AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"ALL ENERGY SOLAR1264 ENERGY LNST PAUL, MN 55108TEL: (800) 620-3370Email:info@allenergysolar.comNEW ELECTRIC SERVICEACCOUNT NUMBER :51-0012439378-9PREMISE NUMBER : 304516119METER NUMBER : 17778890CASE NUMBER : 4982167UTILITY PHONE NUMBER FORSUTDOWN :1-800-628-2121TBD NEW CONSTRUCTION CUSTOMER PHONE NUMBER: (603) 867-8066 INSPECTOR PHONE NUMBER 507-381-1791INSPECTOR -N/AELEVATION PLANELEVATION PLANSCALE: NTS1SOUTH WEST SIDE OF HOUSEPV MODULES rec Alphα® pure Black Series Product Specifications α experience performance 400 wp 20.3 w ft2 ELIGIBLE LEAD-FREE rohs cOMPLIANT www.recgroup.com Ref: PM-DS-12-01-Rev- A 03.21Founded in 1996, REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean, affordable solar power. As Solar’s Most Trusted, REC is committed to high quality, innovation, and a low carbon footprint in the solar materials and solar panels it manufactures. Headquartered in Norway with operational headquarters in Singapore, REC also has regional hubs in North America, Europe, and Asia-Pacific. GR GR GR GR GR 1821±2.5 [71.7±0.1] 901 [35.5]460 [18.1]975±2.5 [38.4±0.1]1100 [43.3] 1200 [47.2] 30 [1.2] 22.5 [0.9] 671 ±3 [26.4 ±0.12] 11±0.2 [0.43±0.01]6.6±0.2 [0.26±0.01]20.5±0.5[0.8±0.02] 6.0±0.2 [0.24±0.01] 28 [1.1]1016±2.5 [40 ±0.1]17 [0.7]45 [1.8] Measurements in mm [in]Specifications subject to change without notice.CERTIFICATIONS WARRANTY LOW LIGHT BEHAVIOUR TEMPERATURE RATINGS* MAXIMUM RATINGS Irradiance (W/m²) Typical low irradiance performance of module at STC:Rel. Efficiency (%)Nominal Module Operating Temperature:44°C (±2°C) Temperature coefficient of PMAX:-0.26 %/°C Temperature coefficient of VOC:-0.24 %/°C Temperature coefficient of ISC:0.04 %/°C *The temperature coefficients stated are linear values Standard REC ProTrust Installed by an REC Certified Solar Professional No Yes Yes System Size All ≤25 kW 25-500 kW Product Warranty (yrs)20 25 25 Power Warranty (yrs)25 25 25 Labor Warranty (yrs)0 25 10 Power in Year 1 98%98%98% Annual Degradation 0.25%0.25%0.25% Power in Year 25 92%92%92% See warranty documents for details. Conditions apply ELECTRICAL DATA Product Code*: RECxxxAA Pure Black Power Output - PMAX (Wp) 385 390 395 400 405 Watt Class Sorting - (W)0/+5 0/+5 0/+5 0/+5 0/+5 Nominal Power Voltage - VMPP (V) 41.2 41.5 41.8 42.1 42.4 Nominal Power Current - IMPP (A) 9.35 9.40 9.45 9.51 9.56 Open Circuit Voltage - VOC (V) 48.5 48.6 48.7 48.8 48.9 Short Circuit Current - ISC (A) 9.99 10.03 10.07 10.10 10.14 Power Density (W/sq ft)19.3 19.6 19.8 20.1 20.3 Panel Efficiency (%) 20.8 21.1 21.3 21.6 21.9 Power Output - PMAX (Wp)293 297 301 305 309 Nominal Power Voltage - VMPP (V) 38.8 39.1 39.4 39.7 40.0 Nominal Power Current - IMPP (A) 7.55 7.59 7.63 7.68 7.72 Open Circuit Voltage - VOC (V) 45.7 45.8 45.9 46.0 46.1 Short Circuit Current - ISC (A) 8.07 8.10 8.13 8.16 8.19 Values at standard test conditions (STC: air mass AM 1.5, irradiance 10.75 W/sq ft (1000 W/m²), temperature 77°F (25°C), based on a production spread with a tolerance of PMAX, VOC & ISC ±3% within one watt class. Nominal module operating temperature (NMOT: air mass AM 1.5, irradiance 800 W/m², temperature 68°F (20°C), windspeed 3.3 ft/s (1 m/s). * Where xxx indicates the nominal power class (PMAX) at STC above. GENERAL DATA Cell type: 132 half-cut REC heterojunction cells with lead-free, gapless technology 6 strings of 22 cells in series Glass:0.13 in (3.2 mm) solar glass with anti-reflection surface treatment Backsheet:Highly resistant polymer (black) Frame:Anodized aluminum (black) Junction box:3-part, 3 bypass diodes, IP67 rated in accordance with IEC 62790 Connectors:Stäubli MC4 PV-KBT4/KST4, 12 AWG (4 mm²) in accordance with IEC 62852 IP68 only when connected Cable:12 AWG (4 mm²) PV wire, 43+ 47 in (1.1 + 1.2 m) accordance with EN 50618 Dimensions:71.7 x 40 x 1.2 in (1821 x 1016 x 30 mm) Weight:45 lbs (20.5 kg) Origin:Made in Singapore STC NMOT85 90 95 100 105 200100 300 400 500 600 700 800 900 1000 Operational temperature:-40 ... +185°F (-40 ... +85°C) Maximum system voltage:1000 V Maximum test load (front): + 7000 Pa (146 lbs/sq ft)* Maximum test load (rear):- 4000 Pa (83.5 lbs/sq ft)* Max series fuse rating:25 A Max reverse current:25 A * See installation manual for mounting instructions. Design load = Test load / 1.5 (safety factor) Product SPECIFICATIONS REC ALPHA PURE BLACK SERIEs > Product SPECIFICATIONS IEC 61215:2016, IEC 61730:2016, UL 61730 (Pending) ISO 14001:2004, ISO 9001:2015, OHSAS 18001:2007, IEC 62941 snapnrack.com Ultra Rail Industry leading Wire Management Solutions Single Tool Installation Mounts available for all roof types All SnapNrack Module Clamps & Accessories are compatible with both raiil profi les Start Installing Ultra Rail Today UR-40 UR-60 The Ultimate Value in Rooftop Solar Solar Mounting Solutions © 2016 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com SnapNrack_Ultra Rail Sales Brochure_v.1.4 SnapNrack Solar Mounting Solutions are engineered to optimize material use and labor resources and improve overall installation quality and safety. Quality. Innovative. Superior. Unparalleled Wire Management • Open rail channel provides room for running wires resulting in a long-lasting quality install • Industry best wire management o ering includes Junction Boxes, Universal Wire Clamps, MLPE Attachment Kits, and Conduit Clamps • System is fully bonded and listed to UL 2703 Standard © 2019 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com SnapNrack Ultra Rail System A sleek, straightforward rail solution for mounting solar modules on all roof types. Ultra Rail features two rail profi les; UR-40 is a lightweight rail profi le that is suitable for most geographic regions and maintains all the great features of SnapNrack rail, while UR-60 is a heavier duty rail profi le that provides a larger rail channel and increased span capabilities. Both are compatible with all existing mounts, module clamps, and accessories for ease of install. The Entire System is a Snap to Install • New Ultra Rail Mounts include snap-in brackets for attaching rail • Compatible with all the SnapNrack Mid Clamps and End Clamps customers love • Universal End Clamps and snap-in End Caps provide a clean look to the array edge Heavy Duty UR-60 Rail • UR-60 rail profi le provides increased span capabilities for high wind speeds and snow loads • Taller, stronger rail profi le includes profi le- specifi c rail splice and end cap • All existing mounts, module clamps, and accessories are retained for the same great install experience MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): DIE CAST A380 ALUMINUM, 6000 SERIES ALUMINUM, STAINLESS STEEL, FOAM SEE STRUCTURAL ENGINEERING SEE STRUCTURAL ENGINEERING 12 LB-FT UL 2703, FILE E359313; WIND-DRIVEN RAIN TEST FROM SUBJECT UL 2582 0.65 OPTIONS: SILVER / BLACK DRAWN BY: mwatkinsSNAPNRACK, ULTRA RAIL SPEEDSEAL™DECKFOOT REVISION: A 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902 THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC.242-02173, 242-02174 PART NUMBER(S): DESCRIPTION: PARTS LIST DESCRIPTIONQTYITEM BOLT, FLANGE, SERRATED, 5/16IN-18 X 1-3/4IN, SS11 SNAPNRACK, RL UNIVERSAL, MOUNT SPRING, SS12 SNAPNRACK, SPEEDSEAL DECKFOOT BASE, SEALING, SILVER / BLACK13 SNAPNRACK, ULTRA RAIL MOUNT THRU PRC, CLEAR14 SNAPNRACK, ULTRA RAIL MOUNT TAPPED PRC, CLEAR15 1 2 4 3 5 NOTE: CAN BE DECK-MOUNTED OR RAFTER-MOUNTED ALL DIMENSIONS IN INCHES DRAWN BY: mwatkinsSNAPNRACK, ULTRA RAIL SPEEDSEAL™DECKFOOT REVISION: A 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902 THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC.242-02173, 242-02174 PART NUMBER(S): DESCRIPTION: 1.00 1.00 1.67 1.00SLOT R.50 TYP 3.05 3.865.20 .93 .93 .93 2.781.78 4.98 3.64