HomeMy WebLinkAboutLA205377 - Approved - Stamped Permit SetAbout the NEP BDM-300X2 As the NEP BDM-300X2 Microinverter we are using is likely unfamiliar to the majority of plan reviewers, here is a brief explanation of some of the particulars of how this piece of equipment fits into our plan sets: 1.The NEP BDM-300X2 is intended to be connected with 2 solar modules (solar panels) per each 1 microinverter. If there is an odd number of solar modules, we are able to have one microinverter with only one panel connected to it. 2.The rated AC output power of this microinverter is 500 watts. Some of you may have specs sheets stating that it is 510. This is based on an out-of-date model. The manufacturer has confirmed that the output power is 500 and has provided us with specs sheets confirming this. 3.The AC system size is to be calculated by multiplying the number of microinverters by the rated AC output power (500). AC system size should NOT be calculated by multiplying the number of microinverters by the peak AC output power (580), as that would be incorrect. 4.The NEP BDM-300X2 does not require a combiner panel unless there is more than one circuit of microinverters being installed. The only exception to this is found in “5”, below: 5.The NEP BDM-300X2 requires the addition of a monitoring system. This monitoring system would ideally be installed in the Main Service Panel via a 15A-2P breaker. If there is not space in the Main Service Panel to install this breaker in addition to our solar interconnection, we will install a combiner panel in order to be able to install this breaker as close as possible to the point of interconnection. STREET VIEW GE VIEW TITLE SHEET PV01 STAMP! 16549 Gunflint TrailROOF AROOF B90 12 0 15 0 18 0 21 0 24 0 27 0 30 0 33 0 0 30 60 W E S N 80 70 50 4O 20 10 35 0 32031 0 290 28 0 260 25 0 23 0 22 0 20 0 19 0 17 0 16 0 140 13 0 11 0 10 0 34 0 AZIMUTH 3 1 2 4 1 ALL EQUIPMENT WILL BE INSTALLED WITHIN 10' OF THE MSP 1'-6" TYP. 3' TYP. 6 5789 24'-3" 35'-8" 16'-10" 16'-3" 3' SITE PLAN PV02 STAMP! SOLAR EQUIPMENT ON THE ROOF SOLAR EQUIPMENT 5' FROM THE MSP MODULES IN A SERIES STRING? J-BOX MODULES IN A SERIES STRING? 2 431 J-BOX 1 5 3 G N (2) 20A-2P CIRCUIT BREAKERS (1) 15A-2P MONITORING BREAKER NEW SUB PANEL TO NEP BDG-256 MONITORING G N 4 6 GN 5 7 ???A-2P G N OTHER LOADS 12 M SERVICE CONDUCTORS EXTENDING TO UTILITY BILLING METERELECTRICAL LINE DIAGRAM PV03 Main Service Panel AC Disconnect (If Used) FOR ILLUSTRATION ONLY (NOT ACTUAL MSP) FOR ILLUSTRATION ONLY (NOT ACTUAL DISCONNECT) NOTES: NOTES: DC CONDUIT MUST BE A REFLECTIVE STICKER *LOCATION: EVERY 10' ALONG ANY CONDUITS OR MC CABLE THAT CONTAIN DC CIRCUITS, AT EVERY ENCLOSURE, AND AT EACH SIDE OF WHERE THE CONDUIT OR CABLE PASSES THROUGH A WALL, FLOOR, OR ANY OTHER PARTITION. EQUIPMENT LABELS PV04 SOLAR MODULE (TYP) BALLAST TRAY RIDGE (TYP) BALLAST TRAY VALLEY (TYP)6' Landscape 2' TYP. 2'2' TYP.ROOF AROOF B2' TYP. 4' TYP. 2' 2' TYP. 4' TYP. 2' 2' TYP. 4' TYP. 3'-2" 2' TYP. 4' TYP. 3'-2" 2' TYP. 4' TYP. 3'-2" 2' TYP. 4' TYP. 3'-2" 2' TYP. 3'-2" 2' TYP. 4' TYP. 3'-2" = STANDOFF ATTACHMENT SPACING ATTACHMENT SPACING PV05 STAMP! THE MAX CANTILEVER IF ANY WILL NOT EXCEED 1'6" RACK & RAIL DIAGRAM PV06 STAMP!! @ ffi fril ® NORTHERN ELECTRIC BDM-300X2 MICROINVERTER Features •Low cost $/watt micro inverter •High peak output power up to 580Wac, recommended for dual max 385W solar panel •High efficiency with 95.5% CEC •Globally certified for UL1741, SAA, TUV, VDE-AR-N 4105, VDE 0126, GB3/2, CEL 021, IEC61727, EN50438, ABNT NBR 6149/16150 •Integrated grounding for easy installation •NEMA-6/IP-66/IP-67 enclosure rating •Integrated monitoring and power line communication with RDG-256 gateway •Con connect with BDM-300 and BDM-250 5.20" CE Important product information � � • NEP is committed to developing Cleon, Affordable, Reliable and 'Efficient (CARE) products for our customers worldwide. • NEP microinverters hove on isolation transformer and basic isolation between the DC input and the AC output network. NORTHERN ELECTRIC BDM-300X2 MICROINVERTER • Grid parameters are configurable through a BDG-256 or BDG-256P3 gateway • All NEC required odjustment factors hove been considered for AC outputs. AC current outputs will not exceed stated values lor Roted Output AC current COMPLIANCE 'NEC 2020 Section 690.11 DC Arc-Fault Circuit Protection 'NEC 2020 section 690.12 Rapid Shutdown of PV systems on Buildings 'NEC 2020 Section 705.12 Point of Connection (AC Arc-Fault Protection) INPUT(DC) DUTPUT(AC) SYSTEM EFFICIENCY PROTECTION FUNCTIONS Recommended Mox PV Power (Wp) Mox DC Open Circuit Voltage (Vdc) Max DC Input current (Ade) MPPT Tracking Accuracy MPPTTrackina Ranae (Vdc) lsc PV (absolute maximum) (Ade) Maximum Inverter Bockfeed Current to the Array (Ade) Peak AC Output Power (Wp) Rated AC Output Power (Wp) Nominal Power Grid Voltage (voe) Allowable Power Grid Voltage (vac) Allowable Power Grid Frequency (Hz) THD Power Factor (cos phi, fixed) Rated Output Current (Aac) current (inrush)(Peak and Duration) Nominal Freauency (Hz) Maximum Output Fault Current (Aac) Maximum Output Overcurrent Protection (Aac) Maximum Number af Units Per Branch (20A) (All NEC adjustment factors have been considered) Weighted Averaged Efficiency (CEC) Night Time Tare Loss (Wp) Over/Under Voltage Protection Over/Under FreQuency Protection Anti-Islanding Protection Over Current Protection Reverse DC Polarity Protection overload Protection Protection Degree Ambient Temperature Operating Temperature Display Com uni cations Dimension (w-H -D) Weight Environment Category Wet Location Pollution Degree Overvoltaae CoteQory Product Safety Compliance Grid Code Compliance• (Refer to the label for the detailed grid code compliance) 450x2 60 14 x2 >99.5% 22-55 18 x2 0 580 500 240 208 I 230 211-264* 183-229* I configurable* 59.3 - 60.5" I configurable* <3% (at rated power) >0.99 ( at rated power) 2.09 2.40 I 2.17 24A, 15us 60 I 50 2.4Arms for 3 cycles 10 7 6 I 6 95.50% 0.11 Yes Yes Yes Yes Yes Yes NEMA-6 / IP-66 / IP-67 -40°F to +149°F (-40°C to +65°C) -40°F to +1B5°F (-40°C to +B5°C) LED LIGHT Power Line 10.9l"x5.20"xl.97"(277X132x50 mm) 6.4 lbs. (2.9 kg) Indoor and outdoor Suitable PD3 ll(PV), 111 (AC MAINS) UL 1741 IEC/EN 62109-1 CSAC22.2 IEC]EN 62109-2 No.107.l VDE-AR-N 4105* VDEV0126-l-l/Al IEEE 1547 G83/2, CEI 021 AS4777:2.6.AS 4777.3,EN50438 ABNT NBR 16149/1615