LA203972-Approved Elec Permit App
1264 Energy Lane 55108 (651) 842-9404 Colin Buechel All Energy Solar 667674 St. Paul MN Installation of a flush mount solar array on the roof of the residence X Colin Buechel SIL - 370 HC RELIABLE ENERGY. DIRECT FROM THE SOURCE. Introducing Silfab Prime Designed to outperform. Dependable, durable, high performance solar panels engineered for North American homeowners. SILFABSOLAR.COM ELECTRICAL SPECIFICATIONS Test Conditions STC NOCT Module Power (Pmax)Wp 370 267 Maximum power voltage (Vpmax)V 34.95 31.68 Maximum power current (Ipmax)A 10.60 8.43 Open circuit voltage (Voc)V 41.75 37.84 Short circuit current (Isc)A 11.25 8.94 Module e iciency % 20.2% 18.3% Maximum system voltage (VDC)V 1000 Series fuse rating A 20 Power Tolerance Wp 0 to +10 Measurement conditions: STC 1000 W/m² • AM 1.5 • Temperature 25 °C • NOCT 800 W/m² • AM 1.5 • Measurement uncertainty ≤ 3% Sun simulator calibration reference modules from Fraunhofer Institute. Electrical characteristics may vary by ±5% and power by 0 to +10W. TEMPERATURE RATINGS Temperature Coeff icient Isc +0.064 %/°C Temperature Coeff icient Voc -0.28 %/°C Temperature Coeff icient Pmax -0.36 %/°C NOCT (± 2°C)45 °C Operating temperature -40/+85 °C SHIPPING SPECS Modules Per Pallet:26 or 26 (California) Pallets Per Truck 34 or 32 (California) Modules Per Truck 884 or 832 (California) WARRANTIES Module product workmanship warranty 25 years** Linear power performance guarantee 30 years ≥ 97.1% end 1st yr≥ 91.6% end 12th yr ≥ 85.1% end 25th yr≥ 82.6% end 30th yr CERTIFICATIONS Product ULC ORD C1703, UL1703, CEC listed***, UL 61215-1/-1-1/-2***, UL 61730-1/-2, IEC 61215-1/-1-1/-2***. IEC 61730-1/-2***, CSA C22.2#61730-1/-2***, IEC 62716 Ammonia Corrosion; IEC61701:2011 Salt Mist Corrosion Certifed, UL Fire Rating: Type 2 MECHANICAL PROPERTIES / COMPONENTS METRIC IMPERIAL Module weight 20kg ±0.2kg 44lbs ±0.4lbs Dimensions (H x L x D)1762 mm x 1037 mm x 35 mm 69.4 in x 40.8 in x 1.37 in Maximum surface load (wind/snow)*5400 Pa rear load / 5400 Pa front load 112.8 lb/ft ^2 rear load / 112.8 lb/ft ^2 front load Hail impact resistance ø 25 mm at 83 km/h ø 1 in at 51.6 mph Cells 120 Half cells - Si mono PERC 9 busbar - 83 x 166 mm 120 Half cells- Si mono PERC 9 busbar - 3.26 x 6.53 in Glass 3.2 mm high transmittance, tempered, DSM antirefl ective coating 0.126 in high transmittance, tempered, DSM antirefl ective coating Cables and connectors (refer to installation manual)1350 mm, ø 5.7 mm, MC4 from Staubli 53.15 in, ø 0.22 in (12AWG), MC4 from Staubli Backsheet High durability, superior hydrolysis and UV resistance, multi-layer dielectric fi lm, fl uorine-free PV backsheet Frame Anodized Aluminum (Black) Bypass diodes 3 diodes-30SQ045T (45V max DC blocking voltage, 30A max forward rectifi ed current) Junction Box UL 3730 Certifi ed, IEC 62790 Certifi ed, IP67 rated * Warning. Read the Safety and Installation Manual for mounting specifi cations and before handling, installing and operating modules. ** 12 year extendable to 25 years subject to registration and conditions outlined under “Warranty” at silfabsolar.com *** Certifi cation anticipated May 2021. PAN fi les generated from 3rd party performance data are available for download at: silfabsolar.com/downloads Silfab - SIL-370 HC No reproduction of any kind is allowed. Data and information is subject to modifi cations without notice. © Silfab 2020.SideBack ViewProfile40.8" [1037mm]2.4" [60mm] 14" [356mm]41.34" [1050mm]14" [356mm] 8" [200mm]39.25" [997mm]53.15"[1350mm]Drainage (x8)Mounting Hole(x4)Ø4.2mm (x2)Grounding Hole69.4" [1762mm]1.4" [35mm]0.3"[7mm]0.5"[12mm]0.6"[15mm]CC1.4" [35mm]1.4" [35mm] 0.06"[1.5mm] 240 Courtneypark Drive East Mississauga ON L5T 2Y3 Canada +1 905.255.2501 +1 905.696.0267 T F T 800 Cornwall Ave Bellingham WA 98225 USA +1 360.569.4733 info@silfabsolar.com SILFABSOLAR.COM SILFAB SOLAR INC. The high-powered smart grid-ready Enphase IQ 7 Micro™ and Enphase IQ 7+ Micro™ dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy™, Enphase IQ Battery™, and the Enphase Enlighten™ monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Enphase IQ 7 and IQ 7+ Microinverters To learn more about Enphase offerings, visit enphase.com Data SheetEnphase MicroinvertersRegion: AMERICAS Easy to Install • Lightweight and simple • Faster installation with improved, lighter two-wire cabling • Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable • Optimized for high powered 60-cell/120 half-cell and 72- cell/144 half-cell* modules • More than a million hours of testing • Class II double-insulated enclosure • UL listed Smart Grid Ready • Complies with advanced grid support, voltage and frequency ride-through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) * The IQ 7+ Micro is required to support 72-cell/144 half-cell modules. 1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility.3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com © 2020 Enphase Energy. All rights reserved. Enphase, the Enphase logo, Enphase IQ 7, Enphase IQ 7+, Enphase IQ Battery, Enphase Enlighten, Enphase IQ Envoy, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subject to change. 2020-08-12 INPUT DATA (DC) IQ7-60-2-US IQ7PLUS-72-2-US Commonly used module pairings¹235 W - 350 W +235 W - 440 W + Module compatibility 60-cell/120 half-cell PV modules only 60-cell/120 half-cell and 72-cell/144 half-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V - 37 V 27 V - 45 V Operating range 16 V - 48 V 16 V - 60 V Min/Max start voltage 22 V / 48 V 22 V / 60 V Max DC short circuit current (module Isc)15 A 15 A Overvoltage class DC port II II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal (L-L) voltage/range²240 V / 211-264 V 208 V / 183-229 V 240 V / 211-264 V 208 V / 183-229 V Maximum continuous output current 1.0 A (240 V)1.15 A (208 V)1.21 A (240 V)1.39 A (208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47 - 68 Hz 47 - 68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A (L-L) branch circuit³16 (240 VAC)13 (208 VAC)13 (240 VAC)11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 18 mA 18 mA Power factor setting 1.0 1.0 Power factor (adjustable)0.85 leading ... 0.85 lagging 0.85 leading ... 0.85 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak efficiency 97.6 %97.6 %97.5 %97.3 % CEC weighted efficiency 97.0 %97.0 %97.0 %97.0 % MECHANICAL DATA Ambient temperature range -40ºC to +65ºC Relative humidity range 4% to 100% (condensing) Connector type MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter) Dimensions (HxWxD)212 mm x 175 mm x 30.2 mm (without bracket) Weight 1.08 kg (2.38 lbs) Cooling Natural convection - No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environmental category / UV exposure rating NEMA Type 6 / outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options.Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA)UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer’s instructions. Enphase IQ 7 and IQ 7+ Microinverters