Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LA203775-Bldg Permit App and Plans
RESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov Submit to: permits@lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: :(676+25( '(6,*1(1*,1((563& 100 GREAT OAKS BLVD. ͿSUITE 115 ALBANY Ϳ NEW YORK Ϳ 12203 :HVW6KRUH'HVLJQ(QJLQHHUVۅ*UHDW2DNV%OYGۅ6XLWHۅ$OEDQ\1<ۅ 6XEMHFW 'XNH5HVLGHQFH *UDQYLOOH/Q /DNHYLOOH01 7R:KRP,W0D\&RQFHUQ 7KHIROORZLQJUHIHUHQFHVWKH'XNH5HVLGHQFHLQ/DNHYLOOH01 ([LVWLQJURRIIUDPLQJ 3UHIDEULFDWHGHQJLQHHUHGZRRGWUXVVLV[DW´RF7KLVH[LVWLQJVWUXFWXUHLVFDSDEOHWRVXSSRUW DOOWKHORDGVLQGLFDWHGEHORZIRUWKLVSKRWRYROWDLFSURMHFW 5RRI/RDGLQJ SVIGHDGORDGPRGXOHVSOXVPRXQWLQJKDUGZDUH SVIJURXQGVQRZORDG SVIURRIPDWHULDOVSVI[SVIVKHDWKLQJSVIDVSKDOWVKLQJOHV ([SRVXUH&DWHJRU\%PSKZLQGVHF 7KLVLQVWDOODWLRQGHVLJQZLOOEHLQJHQHUDOFRQIRUPDQFHWRWKHPDQXIDFWXUHU¶VVSHFLILFDWLRQVDQGFRPSOLHV ZLWKDOODSSOLFDEOHODZVFRGHVDQGRUGLQDQFHVVSHFLILFDOO\WKH,QWHUQDWLRQDO%XLOGLQJ&RGH,%& DQG,QWHUQDWLRQDO5HVLGHQWLDO&RGH,5&LQFOXGLQJDOO01UHJXODWLRQVDQGDPHQGPHQWV7KHVSDFLQJ DQGIDVWHQLQJRIWKHPRXQWLQJEUDFNHWVLVWRKDYHDPD[LPXPRI´RFVSDQEHWZHHQPRXQWLQJEUDFNHWV VWDJJHUHGDQGVHFXUHGXVLQJ´GLDPHWHUFRUURVLYHUHVLVWDQWVWHHOODJEROWVDQGD´HPEHG7LOWXS V\VWHPLQVWDOOHGSHUPDQXIDFWXUHUVSHFLILFDWLRQVDQGUHFRPPHQGDWLRQV 7KDQN\RX :HVWVKRUH'HVLJQ(QJLQHHUV -RKQ(LEHUW1LFRODV1LWWL3( 3URMHFW&RRUGLQDWRU3UHVLGHQW 7R $OO(QHUJ\6RODU )URQW6W &KLFRSHH0$ 'DWH-XQH 5HI LICENSED PROFESSIONAL ENGINEERNICOLAS A . NI TTISTATE OF M I N NESO TA54597 EXP. 6/30/2022 ~128.52'~79.09'~127.72'~79.21'30'-4"18'-3"57'-4"21'-3"ACDMSPUMCBPVMSITE PLAN WITH ROOF PLANREVDATEDESCRIPTIONVERSIONUR06/16/2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-1 PROJECT NAMENALSEEZ DUKE 20545 GRANVILLE LN, LAKEVILLE, MN 55044 USA APN# 224540004260 UTILITY: XCEL ENERGY AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"ALL ENERGY SOLAR1264 ENERGY LNST PAUL, MN 55108TEL: (800) 620-3370Email:info@allenergysolar.comNEW ELECTRIC SERVICEACCOUNT NUMBER :51-0011256917-3PREMISE NUMBER : 304775005METER NUMBER : 22416487CASE NUMBER : 4982430UTILITY PHONE NUMBER FORSUTDOWN :1-800-628-2121TBD NEW CONSTRUCTION CUSTOMER PHONE NUMBER: (612) 850-0629 INSPECTOR PH.# 507-381-INSPECTOR NAME N/ASITE PLAN WITHROOF PLAN1SCALE: 1/16" = 1'-0"NOTE:A. ALL ELECTRICAL EQUIPMENT, INVERTERS,DISCONNECTS, MAIN SERVICE PANELS, ETC.SHALL NOT BE INSTALLED WITHIN 3’ OF THEGAS METERS’ SUPPLY OR DEMAND PIPING.NOTES:1. LOCATION OF SERVICE PANEL AND ELECTRICALEQUIPMENT ARE SHOWN. FINAL LOCATION MAY CHANGE.2. LOCATION OF SERVICE PANEL AND ADDITIONALELECTRICAL EQUIPMENT NOT DRAWN TO SCALE.3. PV INTERCONNECTION IS A SECONDARYINTERCONNECTION4. AC DISCONNECT AND PRODUCTION METER IN READILYACCESSIBLE LOCATION WITHIN 10' OF MAIN READILYSERVICE METER/BI-DIRECTIONAL METER. 24/7UNESCORTED KEYLESS ACCESS TO BE PROVIDED FORUTILITY AC DISCONNECT, PV PRODUCTION METER, &BI-DIRECTIONAL METER.5. PV EQUIPMENT SHALL BE INSTALLED IN ACCORDANCEWITH NEC 690 AND POSTED WITH APPLICABLEWARNINGS, SIGNAGE, AND PLAQUES PER NEC 705-10,690-17, & 690-64 (b)(5).LABELS LOCATED ON PV PRODUCTION METER,BI- DIRECTIONAL METER, AC DISCONNECT (S),INVERTER(S), AND APPROPRIATE LABELS ON MAINELECTRIC SERVICE. ALL LABELS ARE PERMANENT,WEATHERPROOF, AND DURABLE THERE ARE NOCLEARANCE ISSUES DUE TO OVERHEAD POWERLINES.INVERTER SPECIFICATIONSMANUFACTURER / MODEL #ENPHASE ENERGYIQ7A-72-2-USNOMINAL OUTPUT VOLTAGE240 VACNOMINAL OUTPUT CURRENT1.45ADISTANCESSOLAR PANELS - INVERTER: 5' MAXINVERTER'S - IQ COMBINER PANEL : 50'IQ COMBINER PANEL - UTILITY AC DISCONNECT: 2' UTILITY AC DISCONNECT - PV PRODUCTION METER: 2' PV PRODUCTION METER - MAIN ELECTRIC SERVICE: 2' MAIN ELECTRIC SERVICE - BI-DIRECTIONAL METER: 2'OPEN VISIBLE, LOCKABLE, LABELEDAC DISCONNECT LOCATED WITHIN10' OF UTILITY METER(16) REC SOLAR REC 400AA PURE BLACK (400W) MODULES(16) ENPHASE ENERGY IQ7A-72-2-US MICRO-INVERTERS(02) BRANCHES OF 08 MODULES CONNECTED IN PARALLEL PER BRANCHEXISTINGDRIVEWAYGRANVILLE LN PROPERTY LINEPROPERTY LINE PROPERTY LINEPROPERTY LINE TWO- STORYHOUSEROOF #1(16) REC SOLAR REC 400AA PUREBLACK (400W) MODULES(E) UTILITY METER(E) 225A MAIN SERVICE PANELWITH (E) 150A MAIN BREAKER(N) XCEL ENERGY PRODUCTION METER 120/240V,200A WITH BYPASS 1-PHASE, 3-WIRE(N) UTILITY AC DISCONNECT VISIBLE-OPENTYPE, LOCKABLE, READILY ACCESSIBLE(N) ENPHASE IQ COMBINER BOX 310' MAX 6'-7"27'-3"6'-2"7'-3"12'-0"3"ACDMSPUMCBPVMREVDATEDESCRIPTIONVERSIONUR06/16/2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-2 PROJECT NAMENALSEEZ DUKE 20545 GRANVILLE LN, LAKEVILLE, MN 55044 USA APN# 224540004260 UTILITY: XCEL ENERGY AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"ALL ENERGY SOLAR1264 ENERGY LNST PAUL, MN 55108TEL: (800) 620-3370Email:info@allenergysolar.comNEW ELECTRIC SERVICEACCOUNT NUMBER :51-0011256917-3PREMISE NUMBER : 304775005METER NUMBER : 22416487CASE NUMBER : 4982430UTILITY PHONE NUMBER FORSUTDOWN :1-800-628-2121TBD NEW CONSTRUCTION CUSTOMER PHONE NUMBER: (612) 850-0629 INSPECTOR PH.# 507-381-INSPECTOR NAME N/AROOF PLAN WITHMODULESROOF PLAN WITH MODULESSCALE: 1/8" = 1'-0"171.7"40.0"PHOTOVOLTAIC MODULESREC SOLAR REC 400AA PURE BLACK(400W)MODULE TYPE, DIMENSIONS & WEIGHTNUMBER OF MODULES = 16 MODULESMODULE TYPE = REC SOLAR REC 400AA PURE BLACK (400W) MODULESMODULE WEIGHT = 45.0 LBS / 20.5 KG.MODULE DIMENSIONS = 71.7"X 40.0" = 19.92 SFUNIT WEIGHT OF ARRAY = 2.26 PSFROOF DESCRIPTIONROOF TYPECOMP SHINGLE ROOFROOFROOFTILTAZIMUTHTRUSSESSIZETRUSSESSPACING#127°270°2"x4"24" O.C.NOTE: ACTUAL ROOF CONDITIONS AND RAFTERS & TRUSSES(OR SEAM) LOCATIONS MAY VARY. INSTALL PERMANUFACTURER(S) INSTALLATION GUIDELINES ANDENGINEERED SPANS FOR ATTACHMENTSLEGENDUM- UTILITY METERMSP- MAIN SERVICE PANELACD- AC DISCONNECTCB- COMBINER BOXPVM- PRODUCTION METER- VENT, ATTIC FAN(ROOF OBSTRUCTION)- ROOF ATTACHMENT-TRUSSES3'-0"36" FIRE PATHWAY18"18" FIRE PATHWAYR324.6.2 - PROVING ARRAYS TAKELESS THAN 33% OF TOTAL ROOFAREA.WHEN THE ARRAYS TAKE LESSTHAN 33% WE CAN JUSTIFY AN 18"SETBACK ON BOTH SIDES OF THERIDGE. WHEN IT TAKES MORE THAN33% OF THE ROOF AREA WE MUSTUSE A 3' SETBACKS AT THE RIDGE.TOTAL ROOF AREA:2077.00 sqftAREA OF ARRAYS:71.7"X 40.0" ( PANEL DIMENSIONS)71.7"X 40.0" = 19.92 sqft (PER PANEL)19.92 sqftpanel X 16 panels = 318.67 sqft(TOTAL PANEL AREA)PERCENTAGE OF TOTAL ROOF AREA:(318.67 sqft / 2077.00 sqft)(100)= 15.34%THE PANELS USE 15.34% OFTHE TOTAL ROOF AREABILL OF MATERIALSEQUIPMENT QTYDESCRIPTIONRAIL08 SNAPNRACK UR-40 RAILSPLICE04RAIL SPLICEMID CLAMP28 MODULE MID CLAMPEND CLAMP08MODULE END CLAMPATTACHMENT32SNAPNRACK SPEEDSEAL DECKFOOTGROUNDING LUG02GROUNDING LUG(E) UTILITY METER(E) 225A MAIN SERVICE PANELWITH (E) 150A MAIN BREAKER(N) XCEL ENERGY PRODUCTION METER 120/240V,200A WITH BYPASS 1-PHASE, 3-WIRE(N) UTILITY AC DISCONNECT VISIBLE-OPENTYPE, LOCKABLE, READILY ACCESSIBLE(N) ENPHASE IQ COMBINER BOX 3 GRANVILLE LN FRONT YARD REAR YARD 36" FIRE PATHWAY36" FIRE PATHWAY18" FIRE PATHWAY 18" FIRE PATHWAY(E) 2"X4" TRUSSES @ 24" O.C. (TYP.)(N) (32) SNAPNRACK SPEEDSEAL DECKFOOTATTACHMENTS SPACED AT 48" O.C.(N) SNAPNRACK UR-40 RAIL (TYP.)(E) COMP SHINGLE ROOF (TYP.)ROOF #1(16) REC SOLAR REC 400AA PUREBLACK (400W) MODULESROOF #1TILT - 27 AZIMUTH - 27010' MAX REVDATEDESCRIPTIONVERSIONUR06/16/2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-3 PROJECT NAMENALSEEZ DUKE 20545 GRANVILLE LN, LAKEVILLE, MN 55044 USA APN# 224540004260 UTILITY: XCEL ENERGY AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"ALL ENERGY SOLAR1264 ENERGY LNST PAUL, MN 55108TEL: (800) 620-3370Email:info@allenergysolar.comNEW ELECTRIC SERVICEACCOUNT NUMBER :51-0011256917-3PREMISE NUMBER : 304775005METER NUMBER : 22416487CASE NUMBER : 4982430UTILITY PHONE NUMBER FORSUTDOWN :1-800-628-2121TBD NEW CONSTRUCTION CUSTOMER PHONE NUMBER: (612) 850-0629 INSPECTOR PH.# 507-381-INSPECTOR NAME N/AATTACHMENTDETAILSNAPNRACK UR SPEEDSEAL DECKFOOT FOR COMPOSTION ROOFMOUNTING ONTO WOOD DECKING5REFER TO SNAPNRACK ENGINEERING CHARTS FOR APPLICABLERAIL SPANS. "BIN" NUMBER ON CHART SHOULD MATCH "BIN"NUMBER ON THIS DRAWING(X4) #14 FULLY THREADED WOOD SCREWS, S.S. MUST EMBEDFULLY INTO WOOD DECKREFER TO SNAPNRACK INSTALLATION MANUAL FOR 5HARDWARE TORQUE SPECIFICATIONS16"RAIL CAN MOUNT ON EITHER SIDE OF SPEEDSEAL DECKFOOT.SPEEDSEAL DECKFOOT CAN MOUNT UP, DOWN, OR ACROSS THESLOPE OF THE ROOFFOR ADDITIONAL LEVELING DETAILS, REFER TO SNAPNRACKDETAIL DRAWING "SNR-DC-00447 ULTRA RAIL, COMPONENTDETAIL, ULTRA RAIL LEVELING SPACER"SNAPNRACK, SPEEDSEALDECKFOOT BASE, SEALINGSNAPNRACK, UR MOUNTTHRUSNAPNRACK, UR MOUNTTAPPEDEXPLODEDSNAPNRACK, ULTRA RAILTOPCOMP SHINGLE ROOFING, TYP.3.86016"-18 X 13COIL SPRING FOR 34" BOLT,SERRATED FLANGE, S.S.8"BOLT, S.S. (OPTIONAL)5.200MODULE HEIGHT, MAX:UR-40 = 438"COMP SHINGLE ROOFING, TYP.ROOF DECKING, TYP.SCREW HEIGHTOFF ROOF:916"112"158"UR-40 RAILFOR USE WITH SNAPNRACK ULTRA SERIES RAILSMINIMUM DECK THICKNESS:PLYWOOD:15/32"ATTACHMENT DETAILSECTION VIEWOSB: 716"(4X) #14 FULLY THREADEDWOOD SCREW. S.S. MUST EMBEDFULLY INTO WOOD DECKINSTALLATION OVERVIEWROOF DECKING, TYP. GasREVDATEDESCRIPTIONVERSIONUR06/16/2022INITIAL RELEASESHEET NAMESHEET NUMBERPV-4 PROJECT NAMENALSEEZ DUKE 20545 GRANVILLE LN, LAKEVILLE, MN 55044 USA APN# 224540004260 UTILITY: XCEL ENERGY AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"ALL ENERGY SOLAR1264 ENERGY LNST PAUL, MN 55108TEL: (800) 620-3370Email:info@allenergysolar.comNEW ELECTRIC SERVICEACCOUNT NUMBER :51-0011256917-3PREMISE NUMBER : 304775005METER NUMBER : 22416487CASE NUMBER : 4982430UTILITY PHONE NUMBER FORSUTDOWN :1-800-628-2121TBD NEW CONSTRUCTION CUSTOMER PHONE NUMBER: (612) 850-0629 INSPECTOR PH.# 507-381-INSPECTOR NAME N/AELEVATION PLANSOUTH SIDE OF HOUSEEAST SIDE OF HOUSEELEVATION PLANSCALE: NTS1PV MODULES10'-0"23'-6"18'-0" 10'-0" 18'-0" 21'-9"28'-6" 27'-11" rec Alphα® pure Black Series Product Specifications α experience performance 400 wp 20.3 w ft2 ELIGIBLE LEAD-FREE rohs cOMPLIANT www.recgroup.com Ref: PM-DS-12-01-Rev- A 03.21Founded in 1996, REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean, affordable solar power. As Solar’s Most Trusted, REC is committed to high quality, innovation, and a low carbon footprint in the solar materials and solar panels it manufactures. Headquartered in Norway with operational headquarters in Singapore, REC also has regional hubs in North America, Europe, and Asia-Pacific. GR GR GR GR GR 1821±2.5 [71.7±0.1] 901 [35.5]460 [18.1]975±2.5 [38.4±0.1]1100 [43.3] 1200 [47.2] 30 [1.2] 22.5 [0.9] 671 ±3 [26.4 ±0.12] 11±0.2 [0.43±0.01]6.6±0.2 [0.26±0.01]20.5±0.5[0.8±0.02] 6.0±0.2 [0.24±0.01] 28 [1.1]1016±2.5 [40 ±0.1]17 [0.7]45 [1.8] Measurements in mm [in]Specifications subject to change without notice.CERTIFICATIONS WARRANTY LOW LIGHT BEHAVIOUR TEMPERATURE RATINGS* MAXIMUM RATINGS Irradiance (W/m²) Typical low irradiance performance of module at STC:Rel. Efficiency (%)Nominal Module Operating Temperature:44°C (±2°C) Temperature coefficient of PMAX:-0.26 %/°C Temperature coefficient of VOC:-0.24 %/°C Temperature coefficient of ISC:0.04 %/°C *The temperature coefficients stated are linear values Standard REC ProTrust Installed by an REC Certified Solar Professional No Yes Yes System Size All ≤25 kW 25-500 kW Product Warranty (yrs)20 25 25 Power Warranty (yrs)25 25 25 Labor Warranty (yrs)0 25 10 Power in Year 1 98%98%98% Annual Degradation 0.25%0.25%0.25% Power in Year 25 92%92%92% See warranty documents for details. Conditions apply ELECTRICAL DATA Product Code*: RECxxxAA Pure Black Power Output - PMAX (Wp) 385 390 395 400 405 Watt Class Sorting - (W)0/+5 0/+5 0/+5 0/+5 0/+5 Nominal Power Voltage - VMPP (V) 41.2 41.5 41.8 42.1 42.4 Nominal Power Current - IMPP (A) 9.35 9.40 9.45 9.51 9.56 Open Circuit Voltage - VOC (V) 48.5 48.6 48.7 48.8 48.9 Short Circuit Current - ISC (A) 9.99 10.03 10.07 10.10 10.14 Power Density (W/sq ft)19.3 19.6 19.8 20.1 20.3 Panel Efficiency (%) 20.8 21.1 21.3 21.6 21.9 Power Output - PMAX (Wp)293 297 301 305 309 Nominal Power Voltage - VMPP (V) 38.8 39.1 39.4 39.7 40.0 Nominal Power Current - IMPP (A) 7.55 7.59 7.63 7.68 7.72 Open Circuit Voltage - VOC (V) 45.7 45.8 45.9 46.0 46.1 Short Circuit Current - ISC (A) 8.07 8.10 8.13 8.16 8.19 Values at standard test conditions (STC: air mass AM 1.5, irradiance 10.75 W/sq ft (1000 W/m²), temperature 77°F (25°C), based on a production spread with a tolerance of PMAX, VOC & ISC ±3% within one watt class. Nominal module operating temperature (NMOT: air mass AM 1.5, irradiance 800 W/m², temperature 68°F (20°C), windspeed 3.3 ft/s (1 m/s). * Where xxx indicates the nominal power class (PMAX) at STC above. GENERAL DATA Cell type: 132 half-cut REC heterojunction cells with lead-free, gapless technology 6 strings of 22 cells in series Glass:0.13 in (3.2 mm) solar glass with anti-reflection surface treatment Backsheet:Highly resistant polymer (black) Frame:Anodized aluminum (black) Junction box:3-part, 3 bypass diodes, IP67 rated in accordance with IEC 62790 Connectors:Stäubli MC4 PV-KBT4/KST4, 12 AWG (4 mm²) in accordance with IEC 62852 IP68 only when connected Cable:12 AWG (4 mm²) PV wire, 43+ 47 in (1.1 + 1.2 m) accordance with EN 50618 Dimensions:71.7 x 40 x 1.2 in (1821 x 1016 x 30 mm) Weight:45 lbs (20.5 kg) Origin:Made in Singapore STC NMOT85 90 95 100 105 200100 300 400 500 600 700 800 900 1000 Operational temperature:-40 ... +185°F (-40 ... +85°C) Maximum system voltage:1000 V Maximum test load (front): + 7000 Pa (146 lbs/sq ft)* Maximum test load (rear):- 4000 Pa (83.5 lbs/sq ft)* Max series fuse rating:25 A Max reverse current:25 A * See installation manual for mounting instructions. Design load = Test load / 1.5 (safety factor) Product SPECIFICATIONS REC ALPHA PURE BLACK SERIEs > Product SPECIFICATIONS IEC 61215:2016, IEC 61730:2016, UL 61730 (Pending) ISO 14001:2004, ISO 9001:2015, OHSAS 18001:2007, IEC 62941 snapnrack.com SpeedSealTM DeckFoot Eliminates locating rafters & pilot holes Features SpeedSealTM Technology Ability to mount on specialty roof types Pre-assembled with L Foot & Ultra Rail Mount Start Installing the DeckFoot Today Ultra Rail Direct to Deck Attachment for Ultra Rail © 2016 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com SnapNrack Solar Mounting Solutions are engineered to optimize material use and labor resources and improve overall installation quality and safety. Quality. Innovative. Superior. Eliminate Disruption on the Roof • Maintain the roof integrity, no prying up shingles • Each screw independently sealed • Sealant venting ports indicate proper seal © 2021 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com The SpeedSealTM DeckFoot is part of a new generation of roof attachments for Ultra Rail, featuring an innovative design that incorporates SpeedSealTM Technology into a single roof attachment that mounts directly to the deck. Rafter Independent Attachment • Eliminates the need to locate or find rafters for pilot holes • Single attachment secured straight to the roof Ultimate Rooftop Versatility • Allows for layout adjustability on the roof without the need to locate & attach to rafters • Familiar SpeedSealTM Technology with compressible barrier that secures sealant in place & fills voids • Ability to mount on specialty roof structures without standard rafters including TJI’s, metal rafters, tongue & groove, and manufactured homes MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): DIE CAST A380 ALUMINUM, 6000 SERIES ALUMINUM, STAINLESS STEEL, FOAM SEE STRUCTURAL ENGINEERING SEE STRUCTURAL ENGINEERING 12 LB-FT UL 2703, FILE E359313; WIND-DRIVEN RAIN TEST FROM SUBJECT UL 2582 0.65 OPTIONS: SILVER / BLACK DRAWN BY: mwatkinsSNAPNRACK, ULTRA RAIL SPEEDSEAL™ DECKFOOT REVISION: A 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902 THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC.242-02173, 242-02174 PART NUMBER(S): DESCRIPTION: PARTS LIST DESCRIPTIONQTYITEM BOLT, FLANGE, SERRATED, 5/16IN-18 X 1-3/4IN, SS11 SNAPNRACK, RL UNIVERSAL, MOUNT SPRING, SS12 SNAPNRACK, SPEEDSEAL DECKFOOT BASE, SEALING, SILVER / BLACK13 SNAPNRACK, ULTRA RAIL MOUNT THRU PRC, CLEAR14 SNAPNRACK, ULTRA RAIL MOUNT TAPPED PRC, CLEAR15 1 2 4 3 5 NOTE: CAN BE DECK-MOUNTED OR RAFTER-MOUNTED ALL DIMENSIONS IN INCHES DRAWN BY: mwatkinsSNAPNRACK, ULTRA RAIL SPEEDSEAL™ DECKFOOT REVISION: A 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902 THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC.242-02173, 242-02174 PART NUMBER(S): DESCRIPTION: 1.00 1.00 1.67 1.00SLOT R.50 TYP 3.05 3.865.20 .93 .93 .93 2.781.78 4.98 3.64