Loading...
HomeMy WebLinkAboutLA205771-APPROVED - Planset - KalkhoffUM MSP SR PM AC LC SITE PLAN-1 PV-1.0 JONATHAN KALKHOFF - 11.850kW DC, 8.700kW AC SITE PLAN-1 PV-1.0 A SITE PLAN-1 SCALE: 3/32" = 1'-0" INDEX INDEX NO.DESCRIPTION SITE PLAN-1 SITE PLAN-2 GENERAL NOTES MOUNTING DETAILS STRUCTURAL DETAILS SINGLE LINE DIAGRAM WARNING PLACARDS SPEC SHEET(S) PV-1.0 PV-1.1 PV-2.0 PV-3.0 PV-3.1 PV-4.0 PV-5.0 SS ELECTRIC CODE NEC 2020 FIRE CODE MFC 2020 RESIDENTIAL CODE MRC 2020 BUILDING CODE MBC 2020 WIND SPEED 115 MPH SNOW LOAD 50 PSF GENERAL INFORMATION PHOTOVOLTAIC ARRAY ON THE ROOF PV-1.0 A1 VICINITY MAP SCALE: NTS CUSTOMER INFORMATION NAME&ADDRESS: 44° 42.295'N 93° 10.843'W APN:227-850-004-050 AHJ:MN-CITY OF LAKEWILLE UTILITY:DAKOTA ELECTRIC ASSOCIATION SYSTEM INFORMATION DESIGNER/CHECKED BY: RR/LS PROJECT NUMBER:CCEN-006457 SCALE:AS NOTED PAPER SIZE:17"x11" JONATHAN KALKHOFF 16809 ENFIELD WAY, LAKEVILLE, MN 55044. ENGINEER OF RECORD DATE:7/27/2022 REV:A 10361 JAMESTOWN ST NE BLAINE, MN 55449 763-450-9769 LIC:ELEC#EA006457 LIC:GEN#BC638279 DC SYSTEM SIZE: 11850W AC SYSTEM SIZE: 8700W MODULES: (30)REC SOLAR REC395AA PURE INVERTER: (30)ENPHASE IQ8PLUS-72-2-US (240V,1PH) BRANCH DETAILS: 1 BRANCH OF 11 MICRO INVERTERS(11 MODULES) 1 BRANCH OF 10 MICRO INVERTERS(10 MODULES) 1 BRANCH OF 9 MICRO INVERTERS(9 MODULES) NOTE: 1.NO CLEARANCE ISSUES WITH EXISTING OVERHEAD LINES 2.PV PRODUCTION AND UTILITY DISCONNECT ARE ·LOCATED WITHIN 10' OF MAIN SERVICE/BILLING METER ·VISIBLE,LOCKABLE,READILY ACCESSIBLE AND 24/7 ACCESS 3.DESIGN COMPLY WITH NEC AND NEC690 4.LABELS SHALL BE WEATHERPROOF,DURABLE,AND PERMANENTLY MOUNTED 5.24/7 UNESCORTED KEYLESS ACCESS TO METERS AND UTILITY AC DISCONNECTS. 6..SECONDARY INTERCONNECTION. (E) MAIN SERVICE PANEL (INTERIOR) ACCOUNT #200005154968 METER #1ND90313614 (E) MAIN SERVICE METER(EXTERIOR) NOTE: 1. MICRO INVERTERS ARE UL 1741 RATED. 2. MODULES ARE UL1703 RATED. 1' MIN CLEARANCE (N) ENPHASE IQ COMBINER 4 (EXTERIOR) 1'-6" FIRE SETBACK (N) FUSED SR DISCONNECT (EXTERIOR) DISTANCE BETWEEN EQUIPMENT FROM TO DISTANCE(FT) MODULE ENPHASE IQ COMBINER 4 30 ENPHASE IQ COMBINER 4 UTILIY AC DISCONNECT 1 UTILITY AC DISCONNECT UTILIY PV PRODUCTION METER 1 UTILIY PV PRODUCTION METER FUSED SR DISCONNECT 1 FUSED SR DISCONNECT MAIN SERVICE METER 1 (N) UTILITY PV PRODUCTION METER (EXTERIOR) 3'-0" FIRE SET BACK NOTE: CONDUIT RUN IN ATTIC (N) UTILITY AC DISCONNECT (EXTERIOR) 3'-0" WALK WAY 19'-5"17' 23'-2" Concept Approval ONLYSubject to Field Inspection Inspector Date 2020 MN Bldg Code 08/26/2022dpfannenstein UM MSP SR PM AC LC SITE PLAN-2 PV-1.1 JONATHAN KALKHOFF - 11.850kW DC, 8.700kW AC SITE PLAN-2 PV-1.1 A SITE PLAN-2 SCALE: 1/16" = 1'-0" PHOTOVOLTAIC ARRAY ON THE ROOF CUSTOMER INFORMATION NAME&ADDRESS: 44° 42.295'N 93° 10.843'W APN:227-850-004-050 AHJ:MN-CITY OF LAKEWILLE UTILITY:DAKOTA ELECTRIC ASSOCIATION SYSTEM INFORMATION DESIGNER/CHECKED BY: RR/LS PROJECT NUMBER:CCEN-006457 SCALE:AS NOTED PAPER SIZE:17"x11" JONATHAN KALKHOFF 16809 ENFIELD WAY, LAKEVILLE, MN 55044. ENGINEER OF RECORD DATE:7/27/2022 REV:A 10361 JAMESTOWN ST NE BLAINE, MN 55449 763-450-9769 LIC:ELEC#EA006457 LIC:GEN#BC638279 DC SYSTEM SIZE: 11850W AC SYSTEM SIZE: 8700W MODULES: (30)REC SOLAR REC395AA PURE INVERTER: (30)ENPHASE IQ8PLUS-72-2-US (240V,1PH) BRANCH DETAILS: 1 BRANCH OF 11 MICRO INVERTERS(11 MODULES) 1 BRANCH OF 10 MICRO INVERTERS(10 MODULES) 1 BRANCH OF 9 MICRO INVERTERS(9 MODULES) PROPERTY LINE169TH ST WAPPROX.110'WIDTH.30'DRIVE WAY ENFIELD WAY168'-10"89'-2"168'-10" 73'-6"15'-7"18'43'-9" GENERAL NOTES PV-2.0 CUSTOMER INFORMATION NAME&ADDRESS: 44° 42.295'N 93° 10.843'W APN:227-850-004-050 AHJ:MN-CITY OF LAKEWILLE UTILITY:DAKOTA ELECTRIC ASSOCIATION SYSTEM INFORMATION DESIGNER/CHECKED BY: RR/LS PROJECT NUMBER:CCEN-006457 SCALE:AS NOTED PAPER SIZE:17"x11" JONATHAN KALKHOFF 16809 ENFIELD WAY, LAKEVILLE, MN 55044. ENGINEER OF RECORD DATE:7/27/2022 REV:A 10361 JAMESTOWN ST NE BLAINE, MN 55449 763-450-9769 LIC:ELEC#EA006457 LIC:GEN#BC638279 DC SYSTEM SIZE: 11850W AC SYSTEM SIZE: 8700W MODULES: (30)REC SOLAR REC395AA PURE INVERTER: (30)ENPHASE IQ8PLUS-72-2-US (240V,1PH) BRANCH DETAILS: 1 BRANCH OF 11 MICRO INVERTERS(11 MODULES) 1 BRANCH OF 10 MICRO INVERTERS(10 MODULES) 1 BRANCH OF 9 MICRO INVERTERS(9 MODULES) GENERAL NOTES GENERAL NOTES 1.MODULES ARE LISTED UNDER UL 1703 AND CONFORM TO THE STANDARDS. 2.INVERTERS ARE LISTED UNDER UL 1741 AND CONFORM TO THE STANDARDS. 3.DRAWINGS ARE DIAGRAMMATIC, INDICATING GENERAL ARRANGEMENT OF THE PV SYSTEM AND THE ACTUAL SITE CONDITION MIGHT VARY. 4.WORKING CLEARANCES AROUND THE NEW PV ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC CODE. 5.ALL GROUND WIRING CONNECTED TO THE MAIN SERVICE GROUNDING IN MAIN SERVICE PANEL/ SERVICE EQUIPMENT. 6.ALL CONDUCTORS SHALL BE 600V, 75°C STANDARD COPPER UNLESS OTHERWISE NOTED. 7.WHEN REQUIRED, A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 8.THE SYSTEM WILL NOT BE INTERCONNECTED BY THE CONTRACTOR UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND/OR THE UTILITY. 9.ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREES, WIRES OR SIGNS. 10.PV ARRAY COMBINER/JUNCTION BOX PROVIDES TRANSITION FROM ARRAY WIRING TO CONDUIT WIRING EQUIPMENT LOCATION: 11.ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC CODE. 12.WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY NEC CODE AND NEC TABLES. 13.JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO NEC CODE. 14.ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT. 15.ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC APPLICABLE CODES. 16.ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE . STRUCTURAL NOTES: 17.RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, ACCORDING TO RAIL MANUFACTURER’S INSTRUCTIONS. 18.JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCAL REQUIREMENTS. 19.ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED WITH APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. 20.ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 21.WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST THE ROOF FRAMING MEMBERS. WIRING & CONDUIT NOTES: 22.ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. 23.CONDUCTORS SIZED ACCORDING TO NEC CODE. 24.DC WIRING LIMITED TO MODULE FOOTPRINT. MICRO INVERTER WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY WITH SUITABLE WIRING CLIPS. 25.AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACK PHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3- BLUE, YELLOW, ORANGE**, OR OTHER CONVENTION NEUTRAL- WHITE OR GREY IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE [NEC CODE]. INTERCONNECTION NOTES: 26.LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH [NEC CODE] 27.THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS INPUT MAY NOT EXCEED 120% OF BUSBAR RATING [NEC CODE]. 28.WHEN SUM OF THE PV SOURCES EQUALS >100% OF BUSBAR RATING, PV DEDICATED BACKFFED BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY SOURCE OCPD [NEC CODE]. 29.AT MULTIPLE PV OUTPUT COMBINER PANEL, TOTAL RATING OF ALL OVER CURRENT DEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR. HOWEVER, THE COMBINED OVER CURRENT DEVICE MAY BE EXCLUDED ACCORDING TO NEC CODE. 30.FEEDER TAP INTER CONNECTION (LOAD SIDE) ACCORDING TO NEC CODE 31.SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC CODE (A) WITH SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC CODE 32. BACK FEEDING BREAKER FOR UTILITY-INTERACTIVE INVERTER OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING [NEC CODE]. GROUNDING NOTES: 33.GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH USE. 34.PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC CODE AND MINIMUM NEC TABLE. 35.METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES CONSIDERED GROUNDED IN ACCORD. 36.EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC CODE AND MICRO INVERTER MANUFACTURER'S INSTRUCTIONS. 37.EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARE NOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATION REQUIREMENTS. 38.THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER MODULE. 39.GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED GREEN OR MARKED GREEN IF #4 AWG OR LARGER [NEC CODE] 40.THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC CODE. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO NEC CODE AND AHJ. 41.GROUND-FAULT DETECTION SHALL COMPLY WITH NEC CODE IN GENERAL AND NEC CODE SPECIFICALLY. 42.DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: 43.DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS). 44.DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH 45.RAPID SHUTDOWN OF ENERGIZED CONDUCTORS BEYOND 10 FT OF PV ARRAY OR 5 FT INSIDE A BUILDING WITHIN 10 SECONDS. CONTROLLED CONDUCTORS ≤30V AND ≤240VA [NEC CODE]. LOCATION OF LABEL ACCORDING TO AHJ. 46.ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC CODE. 47.MICRO INVERTER BRANCHES CONNECTED TO A SINGLE BREAKER OR GROUPED FUSES IN ACCORDANCE WITH NEC CODE. 2.6.7 IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION ACCORDING TO NEC CODE AND UL1699B. MOUNTING DETAILS PV-3.0 CUSTOMER INFORMATION NAME&ADDRESS: 44° 42.295'N 93° 10.843'W APN:227-850-004-050 AHJ:MN-CITY OF LAKEWILLE UTILITY:DAKOTA ELECTRIC ASSOCIATION SYSTEM INFORMATION DESIGNER/CHECKED BY: RR/LS PROJECT NUMBER:CCEN-006457 SCALE:AS NOTED PAPER SIZE:17"x11" JONATHAN KALKHOFF 16809 ENFIELD WAY, LAKEVILLE, MN 55044. ENGINEER OF RECORD DATE:7/27/2022 REV:A 10361 JAMESTOWN ST NE BLAINE, MN 55449 763-450-9769 LIC:ELEC#EA006457 LIC:GEN#BC638279 DC SYSTEM SIZE: 11850W AC SYSTEM SIZE: 8700W MODULES: (30)REC SOLAR REC395AA PURE INVERTER: (30)ENPHASE IQ8PLUS-72-2-US (240V,1PH) BRANCH DETAILS: 1 BRANCH OF 11 MICRO INVERTERS(11 MODULES) 1 BRANCH OF 10 MICRO INVERTERS(10 MODULES) 1 BRANCH OF 9 MICRO INVERTERS(9 MODULES) PV-3.0 B MOUNTING DETAILS SCALE:1/8" = 1'-0" DEAD LOAD CALCULATIONS BOM QUANTITY LBS/UNIT TOTAL WEIGHT (LBS) MODULES 30 45 1350.00 MID-CLAMP 44 0.050 2.20 END-CLAMP 32 0.050 1.60 RAIL LENGTH 365 0.680 248.20 SPLICE BAR 18 0.360 6.48 SNAPNRACK FLASHED L FOOT 104 1.35 140.40 MICRO-INVERTER 30 2.38 71.40 TOTAL WEIGHT OF THE SYSTEM (LBS)1820.28 TOTAL ARRAY AREA ON THE ROOF (SQ. FT.)597.50 WEIGHT PER SQ. FT.(LBS)3.05 WEIGHT PER PENETRATION (LBS)17.50 MODULES DATA REC SOLAR REC395AA PURE MODULE DIMS 71.7"x40"x1.2" LAG SCREWS 5/16"x3.5":2.5"MIN EMBEDMENT UPLIFT CALCULATIONS UPLIFT 17925.0 LBS PULL OUT STRENGTH 63960 LBS POINT LOADING 13 LBS ALUMINIUM RAILS AERIAL VIEW MINIMUM FIRE ACCESS PATHWAYS PER MFC 2020 RIDGE TO ARRAY: 1'-6" EAVE TO ARRAY : 3'-0" HIP/VALLEY W/ ADJACENT ARRAY: 1'-6" EACH SIDE HIP/VALLEY W/O ADJACENT ARRAY: 0'-0" NOTE: INSTALLER TO VERIFY RAFTER SIZE, SPACING AND SLOPED SPANS, AND NOTIFY ANY DISCREPANCIES BEFORE PROCEEDING. FIRE SETBACK 2 X 4 PRE-FABRICATED TRUSSES@2'-0"SPACING SITE INFORMATION SR.NO AZIMUTH PITCH NO. OF MODULES ARRAY AREA (SQ. FT.)ROOF TYPE ATTACHMENT ROOF EXPOSURE FRAME TYPE FRAME SIZE FRAME SPACING MAX RAIL SPAN OVER HANG MP-01 90°26°19 378.4 ASPHALT SHINGLE SNAPNRACK FLASHED L FOOT ATTIC PRE-FABRICATED TRUSSES 2 X 4 2'-0"4'-0"2'-0" MP-02 180°39°11 219.1 ASPHALT SHINGLE SNAPNRACK FLASHED L FOOT ATTIC PRE-FABRICATED TRUSSES 2 X 4 2'-0"4'-0"2'-0" ARRAY MP-01 ARRAY MP-02 1'-6" 3'4' 29'-11"16'-8"11'-11"29'-11"10' 8/18/22 STRUCTURAL DETAILS PV-3.1 CUSTOMER INFORMATION NAME&ADDRESS: 44° 42.295'N 93° 10.843'W APN:227-850-004-050 AHJ:MN-CITY OF LAKEWILLE UTILITY:DAKOTA ELECTRIC ASSOCIATION SYSTEM INFORMATION DESIGNER/CHECKED BY: RR/LS PROJECT NUMBER:CCEN-006457 SCALE:AS NOTED PAPER SIZE:17"x11" JONATHAN KALKHOFF 16809 ENFIELD WAY, LAKEVILLE, MN 55044. ENGINEER OF RECORD DATE:7/27/2022 REV:A 10361 JAMESTOWN ST NE BLAINE, MN 55449 763-450-9769 LIC:ELEC#EA006457 LIC:GEN#BC638279 DC SYSTEM SIZE: 11850W AC SYSTEM SIZE: 8700W MODULES: (30)REC SOLAR REC395AA PURE INVERTER: (30)ENPHASE IQ8PLUS-72-2-US (240V,1PH) BRANCH DETAILS: 1 BRANCH OF 11 MICRO INVERTERS(11 MODULES) 1 BRANCH OF 10 MICRO INVERTERS(10 MODULES) 1 BRANCH OF 9 MICRO INVERTERS(9 MODULES) MID-CLAMP & END CLAMP DETAIL GROUNDING DETAILS 5/16"-18 SS BOLT SS SPLIT LOCK WASHER (TORQUE TO 16FT-LBS) SNAPNRACK GROUNDING LUG BOUNDING CHANNEL NUT RAIL 6-12 AWG BARE COPPER WIRE NOTES: ·ALL HARDWARE IS INCLUDED FROM MANUFACTURER ·A MINIMUM OF ONE GROUND LUG IS TO BE INSTALLED ON EVERY CONTINUOUS ROW OF MODULES ·GROUNDING LUG MAY BE INSTALLED IN EITHER RAIL CHANNEL ·GROUNDING LUG MAY BE INSTALLED SO GROUND WIRE IS PARALLEL OR PERPENDICULAR TO RAIL ·ENSURE SPLIT LOCK WASHER IS INSTALLED ON TOP OF COPPER WIRE. SCALE:NTS SS BONDING PIN MID CLAMP ASSEMBLY MODULE FRAME RAIL CHANNEL NUT SNAPNRACK GROUNDING MID-CLAMP SCALE: NTS NTS REMOVAL OF ONE PIECE OF EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN ANY OTHER PIECES. SCALE:NTS GROUND BONDING JUMPERRACKING PV MODULE SELF TAPING SCREW MODULE TO MODULE & MODULE TO RAIL SNAPNRACK GROUNDING RAIL TO RAIL PV MODULE RAIL END CLAMP PV MODULE RAIL MID CLAMP SCALE: NTS SCALE: NTS 5/16 HEX-BOLT STAINLESS STEEL 5/16" HANGER BOLT 2.5" EMBEDMENT PILOT HOLE REQUIRED (E)ASPHALT SHINGLE ROOF SNAPNRACK FLASHED L FOOT SNAPNRACK ULTRA RAIL PV MODULE (E) BUILDING STRUCTURE ATTACHMENT DETAIL-SNAPNRACK FLASHED L FOOT SCALE: NTS ROOF FRAMING DETAIL SNAPNRACK FLASHED L FOOT SOLAR MODULE RAIL 6" MAX 2 X 4 PRE-FABRICATED TRUSSES @2'-0" SPACINGLOAD BEARING WALL 8/18/22 FUSED SR DISCONNECT FUSED @ 50A,120/240V, 2P 1-PHASE 3W-DISCONNECT IS LOCATED ON NORTH EXTERIOR WALL OF THE HOUSE 1 (N)(30)ENPHASE IQ8PLUS-72-2-US (240V,1PH) WITH (30)REC SOLAR REC395AA PURE MODULES (1) BRANCH OF (11) MICRO-INVERTERS (11 MODULES) (1) BRANCH OF (10) MICRO-INVERTERS (10 MODULES) (1) BRANCH OF (9) MICRO-INVERTERS (9 MODULES) (N)REC SOLAR REC395AA PURE, 395W MODULES APPROX.5' (N)JUNCTION BOX OR EQUIV 2 APPROX.25' (N)60A FUSED SR DISCONNECT 50A FUSE 4 3 MIN.1' REFERENCE POINT OF APPLICABILITY AC COMBINER WITH ENPHASE ENVOY-S EN-X-IQ-AM1-240-4 120/240V, 1PH,3W NEMA 3R INSTALL (3)20A 2P PV BREAKERS(ONLY FOR SOLAR NO LOAD TO BE ADDED) LOCATED ON THE NORTH EXTERIOR WALL OF THE HOUSE (N)ENPHASE IQ COMBINER 4 15A 20A 20AMIN.1' (N) UTILITY PV PRODUCTION METER M LOAD/BOTTOM SIDE LINE/TOP SIDE MAIN SERVICE PANEL 200A 120/240V,1-PHASE, 2P,3W LOCATED ON NORTH INTERIOR WALL OF THE BASEMENT. (E)GROUND ELECTRODE (E)200A MAIN BREAKER M MAIN SERVICE METER 120/240V 1PH,2P,3WEPS (E)200A END FED MAIN PANEL SUPPLY SIDE TAP (VIA NON-SPLICING LUGS ON LOAD SIDE BUS IN UTILITY METER SOCKET) UTILITY:DAKOTA ELECTRIC ASSOCIATION 1ND90313614 UTILITY PV PRODUCTION METER 100A, 120/240V 1-PH 3W W/ BYPASS HANDLE MILBANK U4801-XL-5T9 IS LOCATED ON NORTH EXTERIOR WALL OF THE HOUSE 3 MIN.1' 20A (N)60A UTILITY AC DISCONNECT 3 MIN.1' UTILIY AC DISCONNECT NON-FUSED @ 60A,120/240V, 2P 1-PHASE 3W-DISCONNECT IS LOCATED ON NORTH EXTERIOR WALL OF THE HOUSE. OPEN TYPE, LOCKABLE READILY ACCESSIBLE SINGLE LINE DIAGRAM PV-4.0 SINGLE LINE DIAGRAM: DC SYSTEM SIZE - 11850W, AC SYSTEM SIZE - 8700W CUSTOMER INFORMATION NAME&ADDRESS: 44° 42.295'N 93° 10.843'W APN:227-850-004-050 AHJ:MN-CITY OF LAKEWILLE UTILITY:DAKOTA ELECTRIC ASSOCIATION SYSTEM INFORMATION DESIGNER/CHECKED BY: RR/LS PROJECT NUMBER:CCEN-006457 SCALE:AS NOTED PAPER SIZE:17"x11" JONATHAN KALKHOFF 16809 ENFIELD WAY, LAKEVILLE, MN 55044. ENGINEER OF RECORD DATE:7/27/2022 REV:A 10361 JAMESTOWN ST NE BLAINE, MN 55449 763-450-9769 LIC:ELEC#EA006457 LIC:GEN#BC638279 DC SYSTEM SIZE: 11850W AC SYSTEM SIZE: 8700W MODULES: (30)REC SOLAR REC395AA PURE INVERTER: (30)ENPHASE IQ8PLUS-72-2-US (240V,1PH) BRANCH DETAILS: 1 BRANCH OF 11 MICRO INVERTERS(11 MODULES) 1 BRANCH OF 10 MICRO INVERTERS(10 MODULES) 1 BRANCH OF 9 MICRO INVERTERS(9 MODULES) OCPD CALCULATIONS: MAIN PANEL RATING:200A, MAIN BREAKER RATING:200A LOAD SIDE TAP:100% ALLOWABLE BACKFEED IS 200A INVERTER OVERCURRENT PROTECTION= INVERTER O/P I X CONTINUOUS LOAD(1.25)X #OF INVERTERS =1.21x1.25x30=45.38 A =>PV BREAKER = 50A CONDUIT SCHEDULE TAG ID CONDUIT SIZE CONDUCTOR NEUTRAL GROUND 1 NONE (6) 12 AWG ENPHASE Q CABLE PER BRANCH CIRCUIT NONE (1) 6 AWG BARE COPPER 2 3/4"EMT OR EQUIV (6) 10 AWG THHN/THWN-2 NONE (1) 10 AWG THHN/THWN-2 3 3/4"EMT OR EQUIV (2) 8 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 4 3/4"EMT OR EQUIV (2) 6 AWG THHN/THWN-2 (1) 6 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 NOTE: 1.EACH MICRO INVERTERS ARE RAPID SHUT COMPLIANT 2.MICROINVERTERS ARE UL 1741 RATED NOTES: 1. PV PV PRODUCTION AND UTILITY DISCONNECT ARE ·LOCATED WITHIN 10' OF MAIN SERVICE/BILLING METER ·VISIBLE,LOCKABLE,READILY ACCESSIBLE AND 24/7 ACCESS 2.SYSTEM PEAK CURRENT 36.30AMPS, 120/240V, 1 PHASE,3-WIRE 3.PV MODULES UL1703 4.MICRO INVERTER UL 1741 5.THE SITE HAS 24/7 KEYLESS ACCESS TO METERS AND UTILITY AC DISCONNECTS. 6.NO CLEARANCE CONCERNS EXISTING WITH UNDERGROUND SERVICE ENTRANCE CONDUCTORS. 7.SECONDARY INTERCONNECTION 8.DESIGN SHALL MEET NEC 2020 MODULE SPECIFICATION MODEL REC SOLAR REC395AA PURE MODULE POWER @ STC 395W OPEN CIRCUIT VOLTAGE:Voc 48.7V MAX POWER VOLTAGE:Vmp 41.8V SHORT CIRCUIT CURRENT:Isc 10.2A MAX POWER CURRENT:Imp 9.45A MICRO INVERTER SPECIFICATIONS MODEL ENPHASE IQ8PLUS-72-2-US (240V,1PH) POWER RATING 290W MAX OUTPUT CURRENT 1.21A CEC WEIGHTED EFFICIENCY 97% MAX NO OF MICRO INVERTERS/BRANCH 13 MAX DC VOLTAGE 60V ELECTRICAL CALCULATION AC WIRE CALCULATIONS:- MATERIAL:COPPER & TEMPERATURE RATING:90°C TAG ID REQUIRED CONDUCTOR AMPACITY CORRECTED AMPACITY CALCULATION TERMINAL RATING CHECK DERATED CONDUCTOR AMPACITY CHECK 1 1.21 X 11 =13.31 X 1.25 =16.64A 30 X 0.96 X 1 =28.80A 16.64A <25A 16.64A <28.80A 2 1.21 X 11 =13.31 X 1.25 =16.64A 40 X 0.96 X 0.8 =30.72A 16.64A <35A 16.64A <30.72A 3 1.21 X 30 =36.30 X 1.25 =45.38A 55 X 0.96 X 1 =52.80A 45.38A <50A 45.38A <52.80A ELECTRICAL NOTES: 1. MAXIMUM DC/AC VOLTAGE DROP SHALL BE NO MORE THAN 2%. 2. BREAKER/FUSE SIZES CONFORMS TO NEC 240.6 CODE SECTION. 3. AC GROUNDING ELECTRODE CONDUCTOR SIZED PER NEC 250.66. 4. AMBIENT TEMPERATURE CORRECTION FACTOR IS BASED ON NEC 690.31(A). 5. AMBIENT TEMPERATURE ADJUSTMENT FACTOR IS BASED ON NEC 310.15(B)(2). 6. MAX. SYSTEM VOLTAGE CORRECTION IS PER NEC 690.7. 7. CONDUCTORS ARE SIZED PER WIRE AMPACITY TABLE NEC 310.15(B)(16). 8. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC 310.10(D). 9. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC 310.10(C). DISTANCE BETWEEN EQUIPMENT FROM TO DISTANCE(FT) MODULE ENPHASE IQ COMBINER 4 30 ENPHASE IQ COMBINER 4 UTILIY AC DISCONNECT 1 UTILITY AC DISCONNECT UTILIY PV PRODUCTION METER 1 UTILIY PV PRODUCTION METER FUSED SR DISCONNECT 1 FUSED SR DISCONNECT MAIN SERVICE METER 1 UM MSP SR PM AC LC PV-5.0 CUSTOMER INFORMATION NAME&ADDRESS: 44° 42.295'N 93° 10.843'W APN:227-850-004-050 AHJ:MN-CITY OF LAKEWILLE UTILITY:DAKOTA ELECTRIC ASSOCIATION SYSTEM INFORMATION DESIGNER/CHECKED BY: RR/LS PROJECT NUMBER:CCEN-006457 SCALE:AS NOTED PAPER SIZE:17"x11" JONATHAN KALKHOFF 16809 ENFIELD WAY, LAKEVILLE, MN 55044. ENGINEER OF RECORD DATE:7/27/2022 REV:A 10361 JAMESTOWN ST NE BLAINE, MN 55449 763-450-9769 LIC:ELEC#EA006457 LIC:GEN#BC638279 DC SYSTEM SIZE: 11850W AC SYSTEM SIZE: 8700W MODULES: (30)REC SOLAR REC395AA PURE INVERTER: (30)ENPHASE IQ8PLUS-72-2-US (240V,1PH) BRANCH DETAILS: 1 BRANCH OF 11 MICRO INVERTERS(11 MODULES) 1 BRANCH OF 10 MICRO INVERTERS(10 MODULES) 1 BRANCH OF 9 MICRO INVERTERS(9 MODULES) ALL PLACARDS SHALL BE OF WEATHER PROOF CONSTRUCTION, BACKGROUND ON ALL PLACARDS SHALL BE RED WITH WHITE LETTERING U.O.N. PLACARD SHALL BE MOUNTED DIRECTLY ON THE EXISTING UTILITY ELECTRICAL SERVICE.FASTENERS APPROVED BY THE LOCAL JURISDICTION 16809 ENFIELD WAY, LAKEVILLE, MN 55044.WARNING PLACARDS SYSTEM UTILIZES MICRO-INVERTERS LOCATED UNDER SOLAR MODULE WARNING PLACARDS POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN WARNING ! NOTE:ALL SIGNAGE CANNOT BE HAND WRITTEN NEC 110.21 LABEL LOCATION UTILITY AC DISCONNECT UTILITY AC DISCONNECT NOTE:ALL PLACARDS SHALL BE OF WEATHER PROOF CONSTRUCTION, DURABLE PERMANENTLY MOUNTED, AND COMPLY TO NEC 690 GENERATION SYSTEM CONNECTED LABEL LOCATION MAIN SERVICE METER WARNING CAUTION: SOLAR CIRCUIT LABEL LOCATION POINT OF INTERCONNECTION (PER CODE: NEC 705.12(2)(b) [ Not Required if Panel board is rated not less than sum of ampere ratings of all overcurrent devices supplying it] WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVER-CURRENT DEVICE WARNING:PHOTOVOLTAIC POWER SOURCE LABEL LOCATION CONDUIT, COMBINER BOX [PER CODE: NEC690.31(G)(3)] WARNING-Electric Shock Hazard No User Serviceable Parts inside Contact authorized service provide for assistance LABEL LOCATION INVERTER, JUNCTION BOXES(ROOF), AC DISCONNECT [PER CODE: NEC 690.13] LABEL LOCATION DISCONNECT, POINT OF INTERCONNECTION [PER CODE: NEC690.13(B)] LABEL LOCATION AC DISCONNECT , POINT OF INTERCONNECTION [PER CODE: NEC 690.54] LABEL LOCATION MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES AND CABLE ASSEMBLES AT LEAST EVERY 10 FT, AT TURNS AND ABOVE/BELOW PENETRATIONS AND ALL COMBINER/JUNCTION BOXES. (PER CODE: IFC605.11.1.4) LABEL LOCATION POINT OF INTERCONNECTION [PER CODE: NEC705.12(D)(4)] ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION AC DISCONNECT,POINT OF INTERCONNECTION [PER CODE: NEC 690.13(B)] DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING LABEL LOCATION AC DISCONNECT,POINT OF INTERCONNECTION [PER CODE: NEC 690.13(B)] LABEL LOCATION WEATHER RESISTANT MATERIAL, DURABLE ADHESDIVE, UL969 AS STANDARD TO WEATHER RATING (UL LISTING OF MARKINGS NOT REQUIRED), MIN 38" LETTER HEIGHT ARIAL OR SIMILAR FONT NON-BOLD,PLACED WITHIN THE MAIN SERVICE DISCONNECT,PLACED ON THE OUTSIDE OF THE COVER WHEN DISCONNECT IS OPERATED WITH THE SERVICE PANEL CLOSED. (PWER CODE: NEC690.15 ,690.13(B)) WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM SOLAR DISCONNECT RATED AC OPERATING CURRENT AC NOMINAL OPERATING VOLTAGE 36.30 240 AMPS AC VAC PHOTOVOLTAIC SYSTEM AC DISCONNECT SWITCH CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRICPV PANELS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN LABEL LOCATION AC DISCONNECT, DC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: NEC690.56(C)(1)) LABEL LOCATION INVERTER,POINT OF INTERCONNECTION [PER CODE: NEC 690.56(C)(3)] RAPID SHUTDOWN SWITCH FOR SOLAR SYSTEM LABEL LOCATION TO BE LOCATED ON XCEL OWNED PRODUCTION METER UTILITY PV PRODUCTION METER PHOTOVOLTAIC ARRAY ON THE ROOF MAIN SERVICE PANEL MAIN SERVICE METER ENPHASE IQ COMBINER 4 FUSED SR DISCONNECT UTILITY PV PRODUCTION METER UTILITY AC DISCONNECT