Loading...
HomeMy WebLinkAboutLA206236 - APPROVED - McMillan Installation - Full Plan Set Redesign 080222 (1)SHEET NUMBER CUSTOMER NAME PROJECT SHEET SUBMITTAL DATENO.REVISION SCALE PROFESSIONAL CERTIFICATION ONE LINE INTERCONNECTION GREENWAY SOLAR MIKE RENEAUMIKE@GREENWAYSOLAR.ORG 0 50 100 FEETSCALEIN 1 6 5 7 8 9 1 2 13 3 4 Q.PEAK MODULES 360 W Pmax 50 TOTAL 1a ENPHASE MICROINVERTERS IQ8+ 50 TOTAL MAIN SERVICE PANEL (EXISTING) UTILITY SERVICE INSIDE RESIDENCEM LABEL 3 LABEL 3 POC & PCC MAIN SERVICE METERUTILITY OWNED 1-PHASE, 3-WIRE, 120/240 V SCHEDULE 1 - EQUIPMENT Q.PEAK DUO BLK-G10+ Enphase I8+ Microinverters Enphase IQ3 Combiner Panel Utility AC Disconnect PV Production Meter Tesla Powerwall 2 Generation Panel Utility AC Fused Disconnect Tesla Gateway Backup Relay Main Service Meter 360 watt Voc Monocrystalline, see notes 240 VAC, 1-Phase, 300 VA peak output 240 VAC, 1-Phase, 3-Wire, 125A Bus 240 VAC, Single Phase, 3-Wire, NEMA 3R 240 VAC, Utility Owned, Single Phase, 3-Wire, Lever Bypass 240 VAC, Single Phase, 3-Wire, 13.5 kWh 240 VAC, Single Phase, 3-Wire 240 VAC, Single Phase, 3-Wire 240 VAC Single Phase, 3-Wire, Automatic Relay Backup Utility Owned Meter, 1-Phase, 3-Wire, 120/240 V 50 50 1 1 2 2 1 1 1 1 1a 2 3 4 5 5a 6 7 8 9 # ITEM QTY DESCRIPTION TESLA GATEWAY 2 240 VAC, 1-PH, 3-WIRENEMA 3R DRAWN BY CHECKED BY DATE PROJECT NUMBER MIKE RENEAU XCEL ENERGY DRAWN BY CHECKED BY DATE PROJECT NUMBER MIKE RENEAU M PV PRODUCTION METERUTILITY OWNED1-PHASE, 3-WIRE, 120/240 VWITH LEVER BYPASS INVERTER COMBINER PANEL240VAC, 1-PH, 3-WIRE, 100ANEMA 3R UTILTY AC DISCONNECT 240 VAC, 1-PH, 3-WIREVISIBLE-OPEN TYPE, LOCKABLE AND READILY ACCESIBLE NEMA 3RWITH SERVICE EQUIPMENT BARRIERS FUSED DISCONNECT 240 VAC, 1-PH, 3-WIREVISIBLE-OPEN TYPE, LOCKABLE AND READILY ACCESIBLE NEMA 3RWITH SERVICE EQUIPMENT BARRIERS 125A 80A RPA 20A 20A 20A 20A 200A EXISTING LOADS200A NOTES: 1-ALL TESTING SHALL BE PERFORMED BY QUALIFIED PERSONNEL, WITH PROPER PROTECTIVE EQUIPMENT 2- THE PRODUCTION METER AND UTILITY AC DISCONNECT LOCATED TOGETHER WITHIN 10’ OF THE MAIN SERVICE METER 3- 24/7 UNESCORTED KEYLESS ACCESS PROVIDED FOR THE METERS AND UTILITY AC DISCONNECT 4- UTILITY AC DISCONNECT IS VISIBLE-OPEN TYPE, LOCKABLE, AND READILY ACCESSIBLE 5-DESIGN MEETS ALL APPLICABLE NEC CODES 6- ALL LABELS SHALL COMPLY WITH NEC MNDIP REFERENCE:3.1 Customer Name:3.2 OID:3.3 RPA3.4 NA3.5 Electrical connectoins of all major components identified3.6 Main service meter and main service panel3.7 Main service protection between DER and utlity3.8 Main service meter voltage and phase(s)3.9 Aggregate kW AC nameplate rating of each DER3.10 AC volage of DER system3.11 Expected individual kW AC nameplate rating of each inverter in system3.12 Number of phases of inverters3.13 Number of phases of DER system3.14 NA3.15 ESS: Configuration Mode being applied for shall be clearly indicated3.16 NA3.17 Indicate any control system3.18 PV Production meter, if applicable, with ownership noted3.19 PV production meter noted to have PV generation wired to line side terminals. Note LINE & LOAD.3.19.1 Customer owned meters not located on the DER side of the Xcel Energy production meter3.20 NA3.21 Visible-open type, lockable, and readily accesible 24/7 AC disconnect labeled “Utility AC Disconnect”3.21.1 Other AC Disconnects shall not be labeled or identified as a “Utility AC Disconnect”3.21.2 Installations requiring Production Meter; the utlity disconnect shall be located between DER and production meter3.21.3 Not requiring a production meter; the Utility AC Disconnect shall be located between the DER and main service3.21.4 Mulitple DER units on single service label Utility AC disconnects 1 of 2, etc3.22 NA CASE NUMBER (OID) LINE LOAD OPERATING MODE 2CParallel Non-Exporting Storage with Renewable Generation, Net Metering DCAC DCAC DCAC 1 2 12 DCAC DCAC DCAC 1 2 13 DC AC DC AC DC AC 1 2 12 DC AC DC AC DC AC + _ TESLA POWERWALL 2 (2) + _ 5 kW, 13.5 kWh NEMA 3R AC DC AC DC GENERATION PANEL 125A MAIN BREAKERNEMA 3R 30A 80A 30A 125A 125A21 Amps Continuous21 Amps Continuous5a MCMILLAN TESLA MODULES 04/29/22 04989566 21199 IXONIA LANELAKEVILLE, MN 55044 CARLTON MCMILLAN COMMBOARDSYSTEM SIZE: 18 kW DC/ 15 kW AC INVERTER NOTES: (50) ENPHASE IQ8+ MICRO- INVERTERS (240V) MAX CONT OUTPUT: 300W TOTAL OUTPUT: 15000W UL1741 CERTIFIED MAX CONT CURRENT: 15.95A (per circuit string) OCPD PROTECTION: 20 A PV MODULE NOTES: Q.PEAK DUO BLK-G10+ max: 360 W Voc: 45.3 Vmpp: 37.13 Isc: 11.14 A Impp: 10.77 A TOTAL: 16000 W DC - - - SHEET NUMBER CUSTOMER NAME SHEET SUBMITTAL DATENO.REVISION SCALE PROFESSIONAL CERTIFICATION ONE LINE LABELING INTERCONNECTION GREENWAY SOLAR MIKE RENEAUMIKE@GREENWAYSOLAR.ORG 0 50 100 FEETSCALEIN LB-130089-10X Per Code: NEC 690.31.G.3 Label Location: (C)(CB)(JB) LB-050081-10X Per Code: NEC 690.13.B Label Location: (DC) (INV) 690_53_2017 Per Code: NEC 690.53 Label Location: (DC) (INV) LB-070004-10X Per Code: 690.41.B Label Location: (DC) (INV) LB-010001-10X Per Code: CEC 690.13.B Label Location: (DC) (CB) LB-050082-10X Per Code: NEC 690.13.B Label Location: (AC) (POI) LB-040007-10X Per Code: NEC 690.54 Label Location: (AC) (POI) LB-070005-10X Per Code: NEC 690.13.B Label Location: (AC)(POI) LB_040108_10X Per Code: NEC 690.56.C.3 Label Location: (INV) LB-070039-10X Per Code: NEC 705.12.B.2.3.b Label Location: (POI) LB-040008-10X Per Code: NEC 690.64.B.4 Label Location: (D) (POI) LB-040009-10X Per Code: NEC 705.12.B.3 Label Location: (POI) LB-060046-10X Per Code: CEC 690.13.B Label Location: (POI) LB-070016-10X Label Location: (DC) (INV) LB-250001-10X Per Code: 690.56(C)(1)(b) Label Location: ABB/Delta Solivia Inverter LB-250002-34X Per Code: 690.56(C)(1)(a) Label Location: SolarEdge and,Delta M-Series and,Telsa Inverter (POI): Point of Interconnection(M): Utility Meter(LC): Load Center(INV): Inverter With Integrated DC Disconnect(IC): Interior Run Conduit(DC): DC Disconnect(D): Distribution Panel(CB): Combiner Box(C): Conduit(AC): AC Disconnect PROJECT DRAWN BY CHECKED BY DATE PROJECT NUMBER MIKE RENEAU DRAWN BY CHECKED BY DATE PROJECT NUMBER MIKE RENEAU Per Code: 690.56(C)(1)(a) Label Location: At Disconnects N 21199 IXONIA LANELAKEVILLE, MN 55044 CASE NUMBER (OID) IXONIA LANE LOCATION OF DISCONNECTS NOTES: 1-ALL TESTING SHALL BE PERFORMED BY QUALIFIED PERSONNEL, WITH PROPER PROTECTIVE EQUIPMENT 2- THE PRODUCTION METER AND UTILITY AC DISCONNECT LOCATED TOGETHER WITHIN 10’ OF THE MAIN SERVICE METER 3- 24/7 UNESCORTED KEYLESS ACCESS PROVIDED FOR THE METERS AND UTILITY AC DISCONNECT 4- UTILITY AC DISCONNECT IS VISIBLE-OPEN TYPE, LOCKABLE, AND READILY ACCESSIBLE 5-DESIGN MEETS ALL APPLICABLE NEC CODES 6- ALL LABELS SHALL COMPLY WITH NEC MCMILLAN TESLA MODULES 04/29/22 04989566 21199 IXONIA LANELAKEVILLE, MN 55044 CARLTON MCMILLAN DRIVEWAY FRONT OF HOUSE SOLAR ARRAY SOLAR ARRAYSOLAR ARRAY SOLAR ARRAY